AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » ELS100-S24TX2M-MIB

ELS100-S24TX2M-MIB device MIB details by Enterasys Networks Inc

ELS100-S24TX2M-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ELS100-S24TX2M-MIB.


Vendor: Enterasys Networks Inc
Mib: ELS100-S24TX2M-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
ELS100-S24TX2M-MIB DEFINITIONS ::= BEGIN

IMPORTS
        internet
                FROM RFC1155-SMI
        MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress
                FROM SNMPv2-SMI
        DisplayString
                FROM SNMPv2-TC;


-- private             OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises         OBJECT IDENTIFIER ::= { private 1 }
-- cabletron           OBJECT IDENTIFIER ::= { enterprises 52 }
-- namingTree          OBJECT IDENTIFIER ::= { cabletron 3 }
-- mtExpanded          OBJECT IDENTIFIER ::= { namingTree 9 }
-- mtThrdParty         OBJECT IDENTIFIER ::= { mtExpanded 1 }
-- tpStandAlone        OBJECT IDENTIFIER ::= { mtThrdParty 10 }


tpELS100S24TX2M     MODULE-IDENTITY
        LAST-UPDATED    "200202202202Z"  -- Wed Feb 20 22:02 GMT 2002
        ORGANIZATION    "Enterasys Networks, Inc."
        CONTACT-INFO
            "Enterasys Networks, Inc.
             35 Industrial Way, P.O. Box 5005
             Rochester, NH 03867-5005
             (603) 332-9400
             support@enterasys.com
             http://www.enterasys.com"
        DESCRIPTION
                "The MIB module for ELS100-S24TX2M."

        REVISION  "200208051753Z"  -- Mon Aug  5 17:53 GMT 2002
        DESCRIPTION
                "Added switchOIDTable for identifying the individual
                 switches in a stack of switches."

        REVISION  "200202202202Z"  -- Wed Feb 20 22:02 GMT 2002
        DESCRIPTION
                "Pretty print."

        REVISION  "199910010000Z"
        DESCRIPTION
                "Initial version of this MIB."
        -- ::= { tpStandAlone 7 }

        ::= { internet private(4) enterprises(1) cabletron(52)
                       namingTree(3) mtExpanded(9) mtThrdParty(1)
                       tpStandAlone(10) 7 }


switchInfo          OBJECT IDENTIFIER ::= { tpELS100S24TX2M 1 }
switchPortMgt       OBJECT IDENTIFIER ::= { tpELS100S24TX2M 2 }
systemSTAMgt        OBJECT IDENTIFIER ::= { tpELS100S24TX2M 3 }
tftpDownloadMgt     OBJECT IDENTIFIER ::= { tpELS100S24TX2M 4 }
restartMgt          OBJECT IDENTIFIER ::= { tpELS100S24TX2M 5 }
portMirrorMgt       OBJECT IDENTIFIER ::= { tpELS100S24TX2M 6 }
igmpMgt             OBJECT IDENTIFIER ::= { tpELS100S24TX2M 7 }


--
-- switchInfo
--

switchNumber  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total number of switches present on this system."
        ::= { switchInfo 1 }


switchInfoTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF SwitchInfoEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table of descriptive and status information about
             switches in this system."
        ::= { switchInfo 2 }

switchInfoEntry OBJECT-TYPE
        SYNTAX      SwitchInfoEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the table, containing information
             about a single switch in this system. "
        INDEX { swUnitIndex }
        ::= { switchInfoTable 1 }

SwitchInfoEntry ::= SEQUENCE
{
        swUnitIndex             Integer32,
        swMainBoardHwVer        DisplayString,
        swMainBoardFwVer        DisplayString,
        swAgentBoardHwVer       DisplayString,
        swAgentBoardFwVer       DisplayString,
        swAgentBoardPOSTCodeVer DisplayString,
        swPortNumber            Integer32,
        swPowerStatus           INTEGER,
        swExpansionSlot1        INTEGER,
        swExpansionSlot2        INTEGER,
        swRoleInSystem          INTEGER
}

swUnitIndex         OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the switch within the system
             for which this entry contains information. This
             value can never be greater than switchNumber."
        ::= { switchInfoEntry 1 }

swMainBoardHwVer   OBJECT-TYPE
        SYNTAX     DisplayString (SIZE(0..20))
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "Hardware version of the main board."
        ::= { switchInfoEntry 2 }

swMainBoardFwVer   OBJECT-TYPE
        SYNTAX     DisplayString (SIZE(0..20))
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "Firmware version of the main board."
        ::= { switchInfoEntry 3 }

swAgentBoardHwVer  OBJECT-TYPE
        SYNTAX     DisplayString (SIZE(0..20))
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "Hardware version of the agent board."
        ::= { switchInfoEntry 4 }

swAgentBoardFwVer  OBJECT-TYPE
        SYNTAX     DisplayString (SIZE(0..20))
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "Firmware version of the agent board."
        ::= { switchInfoEntry 5 }

swAgentBoardPOSTCodeVer    OBJECT-TYPE
        SYNTAX     DisplayString (SIZE(0..20))
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "POST code version of the agent board."
        ::= { switchInfoEntry 6 }

swPortNumber       OBJECT-TYPE
        SYNTAX     Integer32
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "The total port number of this switch
             (including expansion slot)."
        ::= { switchInfoEntry 7 }

swPowerStatus      OBJECT-TYPE
        SYNTAX     INTEGER {
              internalPower(1),
              redundantPower(2),
              internalAndRedundantPower(3)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Indicates the switch using internalPower(1),
             redundantPower(2) or both(3)"
        ::= { switchInfoEntry 8 }

swExpansionSlot1   OBJECT-TYPE
        SYNTAX     INTEGER {
              hundredBaseFX2Port(1),
              thousandBaseSX(2),
              stackingModule4GB(3),
              hundredBaseFX1Port(4),
              thousandBaseLX(5),
              thousandBaseT(6),
              thousandBaseGBIC(7),
              stackingModule2GB(8),
              other(9),
              notPresent(10)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Type of expansion module in this switch slot 1."
        ::= { switchInfoEntry 9 }

swExpansionSlot2    OBJECT-TYPE
        SYNTAX      INTEGER {
              hundredBaseFX2Port(1),
              thousandBaseSX(2),
              stackingModule4GB(3),
              hundredBaseFX1Port(4),
              thousandBaseLX(5),
              thousandBaseT(6),
              thousandBaseGBIC(7),
              stackingModule2GB(8),
              other(9),
              notPresent(10)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Type of expansion module in this switch slot 2."
        ::= { switchInfoEntry 10 }

swRoleInSystem      OBJECT-TYPE
        SYNTAX      INTEGER {
              master(1),
              backupMaster(2),
              slave(3)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Indicates the switch is master(1), backupMaster(2)
             or slave(3) in this system."
        ::= { switchInfoEntry 11 }


switchOIDTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF SwitchOIDEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table of System Object Identifiers for switches
             in this system."
        ::= { switchInfo 3 }

switchOIDEntry OBJECT-TYPE
        SYNTAX      SwitchOIDEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the table, containing System Object
             Identifier for a single switch in this system."
        INDEX { switchOIDIndex }
        ::= { switchOIDTable 1 }

SwitchOIDEntry ::= SEQUENCE
{
    switchOIDIndex          INTEGER,
    switchOIDValue          OBJECT IDENTIFIER
}

switchOIDIndex OBJECT-TYPE
        SYNTAX      INTEGER( 1 .. 65535 )
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the switch within the system
             for which this entry contains information. This
             value can never be greater than switchNumber.

             Index value 1 always represents the Master in a
             stacked configuration and the only device in a
             standalone configuration.

             Subsequent indices are sequential with the lowest
             number representing the Slave nearest the Master
             and so on."
        ::= { switchOIDEntry 1 }

switchOIDValue OBJECT-TYPE
        SYNTAX      OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object contains the System Object Identifier
             that uniquely identifies the type of switch."
        ::= { switchOIDEntry 2 }


--
-- switchPortMgt
--

switchPortMgtTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF SwitchPortMgtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table of descriptive and status information about
             configuration of each switch ports (including
             expansion slot) in this system."
        ::= { switchPortMgt 1 }

switchPortMgtEntry  OBJECT-TYPE
        SYNTAX      SwitchPortMgtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the table, containing information about
             configuration in one switch port of the switch."
        INDEX { swUnitIndex, swPortMgtIndex }
        ::= { switchPortMgtTable 1 }

SwitchPortMgtEntry ::= SEQUENCE
{
        swPortMgtIndex              Integer32,
        swPortMgtPortType           INTEGER,
        swPortMgtSpeedDpxAdmin      INTEGER,
        swPortMgtSpeedDpxInUse      INTEGER,
        swPortMgtFlowCtrlAdmin      INTEGER,
        swPortMgtFlowCtrlInUse      INTEGER
}

swPortMgtIndex      OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the port within the switch
             for which this entry contains information."
        ::= { switchPortMgtEntry 1 }

swPortMgtPortType   OBJECT-TYPE
        SYNTAX      INTEGER {
              hundredBaseTX(1),
              hundredBaseFX(2),
              thousandBaseSX(3)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Indicates the port type is tenBaseT/hundredBaseTX(1),
             hundredBaseFX(2) or thousandBaseSX(3)."
        ::= { switchPortMgtEntry 2 }

swPortMgtSpeedDpxAdmin  OBJECT-TYPE
        SYNTAX      INTEGER {
              halfDuplex10(1),
              fullDuplex10(2),
              halfDuplex100(3),
              fullDuplex100(4),
              halfDuplex1000(5),
              fullDuplex1000(6),
              autoNegotiation(7)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Set the port speed and duplex mode as follows:
                halfDuplex10(1)    - 10Mbps and half duplex mode
                fullDuplex10(2)    - 10Mbps and full duplex mode
                halfDuplex100(3)   - 100Mbps and half duplex mode
                fullDuplex100(4)   - 100Mbps and full duplex mode
                halfDuplex1000(5)  - 1000Mbps and half duplex mode
                fullDuplex1000(6)  - 1000Mbps and full duplex mode
                autoNegotiation(7) - let the switch to negotiate with
                                     the other end of connection.
                hundredBaseTX port can be set as
                             halfDuplex10(1)
                             fullDuplex10(2)
                             halfDuplex100(3)
                             fullDuplex100(4)
                             autoNegotiation(7)

                hundredBaseFX port can be set as
                             halfDuplex100(3)
                             fullDuplex100(4)

                thousandBaseSX port can be set as
                             halfDuplex1000(5)
                             fullDuplex1000(6)
                             autoNegotiation(7)

             The actual operating speed and duplex of the port is
             given by swPortMgtSpeedDpxInUse."
        DEFVAL { autoNegotiation }
        ::= { switchPortMgtEntry 3 }

swPortMgtSpeedDpxInUse  OBJECT-TYPE
        SYNTAX      INTEGER {
              halfDuplex10(1),
              fullDuplex10(2),
              halfDuplex100(3),
              fullDuplex100(4),
              halfDuplex1000(5),
              fullDuplex1000(6)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The operating speed and duplex mode of the switched port."
        ::= { switchPortMgtEntry 4 }

swPortMgtFlowCtrlAdmin OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2),
              backPressure(3),
              dot3xFlowControl(4)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "(1) Flow control mechanism is enabled.

                 If the port type is hundredBaseTX or thousandBaseSX:
                     When the port is operating in halfDuplex mode,
                       the port uses backPressure flow control mechanism.
                     When the port is operating in fullDuplex mode,
                       the port uses IEEE 802.3x flow control mechanism.

                 If the port type is hundredBaseFX:
                     When the port is operating in halfDuplex mode, the
                         port uses backPressure flow control mechanism. When
                         the port is operating in fullDuplex mode, Flow
                         control mechanism will not function.

             (2) Flow control mechanism is disabled.

             (3) Flow control mechanism is backPressure.

                 When the port is in fullDuplex mode
                    this flow control mechanism will not function.

             (4) Flow control mechanism is IEEE 802.3x flow control.

                    When the port is in halfDuplex mode
                         this flow control mechanism will not function.

             hundredBaseTX and thousandBaseSX port can be set as:
                  enabled(1),
                  disabled(2),
                  backPressure(3),
                  dot3xFlowControl(4).

             hundredBaseFX port can be set as:
                  enabled(1),
                  disabled(2),
                  backPressure(3).
             The actual flow control mechanism is used given by
             swPortMgtFlowCtrlInUse."
        DEFVAL { enabled }
        ::= { switchPortMgtEntry 5 }

swPortMgtFlowCtrlInUse  OBJECT-TYPE
        SYNTAX      INTEGER {
              backPressure(1),
              dot3xFlowControl(2),
              none(3)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "(1) BackPressure flow control mechanism is used.
             (2) IEEE 802.3 flow control mechanism is used.
             (3) Flow control mechanism is disabled. "
        ::= { switchPortMgtEntry 6 }


--
-- systemSTAMgt
--

systemSTAStatus     OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Global spanning tree status.
               (1) Spanning tree protocol is enabled.
               (2) Spanning tree protocol is disabled. "
        DEFVAL  { enabled }
        ::= { systemSTAMgt 1 }

--
-- tftpDownloadMgt
--

tftpDownloadServerIP OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The IP address of a TFTP server from which a
             firmware image can be downloaded."
        DEFVAL { '00000000'H }
        ::= { tftpDownloadMgt 1 }

--tftpDownloadMainBoardFwFileName OBJECT-TYPE
--        SYNTAX     DisplayString(SIZE(0..80))
--        MAX-ACCESS read-write
--        STATUS      current
--        DESCRIPTION ""
--        DEFVAL { "es3526f.bin" }
--        ::= { tftpDownloadMgt 2 }

--tftpDownloadMainBoardFwSelected OBJECT-TYPE
--        SYNTAX     INTEGER {
--              selected(1),
--              notSelected(2)
--        }
--        MAX-ACCESS read-write
--        STATUS     current
--        DESCRIPTION
--            "Setting this object as selected. The system will download
--             main board firmware when the download action be trigged."
--        DEFVAL { notSelected }
--        ::= { tftpDownloadMgt 3 }

tftpDownloadAgentBoardFwFileName OBJECT-TYPE
        SYNTAX      DisplayString(SIZE(0..80))
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION ""
        DEFVAL { "es3526f.bin" }
        ::= { tftpDownloadMgt 2 }

tftpDownloadAgentBoardFwDownloadNode OBJECT-TYPE
        SYNTAX      INTEGER {
              permanent(1),
              temporary(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Indicates whether a newly upgraded firmware
             version should write to flash.  When this object
             is temporary(2), following a successful upgrade
             the system will switch to run the new firmware but
             will not upgrade the new firmware to flash.  That
             means after a power cycle, system will run the
             firmware residing the flash.
             When this object is permanent(1), following a
             successful firmware upgrade, the flash will be
             upgraded and the system will automatically switch
             to run the new firmware."
        DEFVAL { permanent }
        ::= { tftpDownloadMgt 3 }

--tftpDownloadAgentBoardFwSelected  OBJECT-TYPE
--        SYNTAX     INTEGER {
--              selected(1),
--              notSelected(2)
--        }
--        MAX-ACCESS read-write
--        STATUS      current
--        DESCRIPTION
--            "Setting this object as selected. The system will download
--             agent board firmware when the download action be trigged."
--        DEFVAL { notSelected }
--        ::= { tftpDownloadMgt 4 }

tftpDownloadStatus OBJECT-TYPE
        SYNTAX     INTEGER {
              active(1),
              notActive(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object to active(1) trigger the TFTP
             download action.  Setting this object to notActive(2)
             has no effect.  The system always returns the value
             notActive(2) when this object is read."
  ::= { tftpDownloadMgt 4 }

--
-- restartMgt
--

restartOptionPOST  OBJECT-TYPE
        SYNTAX     INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object as enabled. The system will do POST
             when it restart"
        DEFVAL { enabled }
        ::= { restartMgt 1 }

restartOptionReloadFactoryDefault   OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object as enabled. The system will do
             factory reset when it restart"
        DEFVAL { disabled }
        ::= { restartMgt 2 }

restartOptionKeepIpSetting   OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object as enabled. The system will keep IP
             setting when it do factory reset."
        DEFVAL { enabled }
        ::= { restartMgt 3 }

restartOptionKeepUserAuthentication   OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object as enabled. The system will keep
             user authentication setting when it do factory reset."
        DEFVAL { enabled }
        ::= { restartMgt 4 }

restartAction   OBJECT-TYPE
        SYNTAX      INTEGER {
              active(1),
              notActive(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object to active(1) trigger the system
             restart.  Setting this object to notActive(2) has
             no effect.  The system always returns the value
             notActive(2) when this object is read."
        ::= { restartMgt 5 }

--
-- portMirrorMgt
--

portMirrorStatus    OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Port mirroring function status.
                (1) mirroring function is enabled.
                (2) mirroring function is disabled."
        ::= { portMirrorMgt 1 }

portMirrorSnifferPort   OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Linear port number of sniffer port to which all
             frames to/from mirrored ports are sent. Frames
             are only mirrored if the portMirrorStatus object
             is set to enabled(1)."
        ::= { portMirrorMgt 2 }


portMirrorMirroredPort  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Linear port number of mirrored port. The traffic of
             mirrored port will be 'copied' to sniffer port."
        ::= { portMirrorMgt 3 }

--
-- igmpMgt
--

igmpStatus          OBJECT-TYPE
        SYNTAX      INTEGER {
              enabled(1),
              disabled(2)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Parameter to enable or disable IGMP snooping on the device.
             When enabled, the device will examine IGMP packets and set
             up filters for IGMP ports. The default is enabled."
        ::= { igmpMgt 1 }

igmpQueryCount      OBJECT-TYPE
        SYNTAX      INTEGER (2..16)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Maximum number of queries that have not been heard on the
             system before the system starts taking action to solicit
             reports(default is 5)."
        ::= { igmpMgt 2 }


igmpReportDelay     OBJECT-TYPE
        SYNTAX      INTEGER (3..10)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Timeout value(mins) between IGMP reports received on a port
             for an IP Multicast Address that can pass before the system
             sends an IGMP Query out the port and removes it from the
             list(default is 5 minutes)."
        ::= { igmpMgt 3 }

END