AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » IRM3-MIB

IRM3-MIB device MIB details by Enterasys Networks Inc

IRM3-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing IRM3-MIB.


Vendor: Enterasys Networks Inc
Mib: IRM3-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
IRM3-MIB DEFINITIONS ::= BEGIN

--  irm3-mib.txt
--  Revision: 1.04.01
--  Part Number:  2170568-01
--  Date: June 20, 1996

--  Cabletron Systems, Inc.
--  35 Industrial Way, P.O. Box 5005
--  Rochester, NH 03867-0505
--  (603) 332-9400
--  support@ctron.com

--  This module provides authoritative definitions for Cabletron's
--  repeater MIB for the IRM3.
--
--  This module will be extended, as required.
--

--  Cabletron Systems reserves the right to make changes in 
--  specification and other information contained in this document 
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental, 
--  indirect, special, or consequential damages whatsoever (including 
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the 
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.

--  Copyright August 94 Cabletron Systems

IMPORTS
    NetworkAddress, Counter
        FROM RFC1155-SMI
    repeaterRev1, repeaterRev2, subSysMMAC
        FROM IRM-OIDS
    DisplayString
        FROM RFC1213-MIB
    OBJECT-TYPE FROM RFC-1212;

--  This MIB module uses the extended OBJECT-TYPE macro as defined in RFC 1212

--  Textual convention

--  DisplayString       ::= OCTET STRING
--  This data type is used to model textual information taken from the NVT
--  ASCII character set.  By convention, objects with this syntax, unless
--  explicitly stated, are declared as having:
--
--  SIZE (0..255)

--  MAC addresses will be represented in a canonical form.



--  Formal definitions for RepeaterRev1

device          OBJECT IDENTIFIER ::= { repeaterRev1 1 }

board           OBJECT IDENTIFIER ::= { repeaterRev1 2 }

port            OBJECT IDENTIFIER ::= { repeaterRev1 3 }

sourceAddr      OBJECT IDENTIFIER ::= { repeaterRev1 7 }
     
redundancy      OBJECT IDENTIFIER ::= { repeaterRev1 8 }

alarm           OBJECT IDENTIFIER ::= { repeaterRev1 9 }


--  Device Object Definitions

--  This section defines the objects under the Device node.
--  Again, there is only one instance of a Device object in any device.


deviceMMACType  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                unknown(1),             --  none of the following
                mMAC8(2),
                mMAC5(3),
                mMAC3(4),
                mINIMMAC(5),
                mRXI(6),
                m3Shunt(7),
                m5Shunt(8),
                m8FNB(9),
                nonFNB(10),
                mMAC3Shunting(11),
                mMAC5Shunting(12),
                mMAC8Shunting(13),
                m8Shunting(14)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "Indicates the type of MMAC."
    ::= { device 2 }

deviceSlots     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "Number  of  available  device  slots  in  this  device, including the
         IRM slot."
    ::= { device 3 }

deviceOccupiedSlots     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain MIM boards.  This field  is bit encoded (eg.
         if a  bit is set then that board  is present).  For example, a value
         of 3 indicates that there are boards in  the  IRM slot and the first
         MIM slot."
    ::= { device 4 }

devicePortsOn   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of operating ports on the device."
    ::= { device 5 }

deviceTotalPorts        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The total number of repeater ports on the MMAC."
    ::= { device 6 }

deviceTotalPkts OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only    
    STATUS      mandatory
    DESCRIPTION
        "The number of packets detected on all ports of this device."
    ::= { device 7}

deviceTotalErrors       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of all of the errors listed including alignment, CRC, runts,
         giants, and out of window collisions."
    ::= { device 8 }

deviceTransmitColls     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of transmit collisions detected by this MMAC."
    ::= { device 9 }

deviceRecColls  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of receive collisions detected by this MMAC."
    ::= { device 10 }

deviceAlignErrs OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets with alignment errors detected."
    ::= { device 11 }

deviceCRCErrs   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets with bad CRC detected."
    ::= { device 12 }

deviceRunts     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number  of runt  frames detected  by  this  device."
    ::= { device 13 }

deviceOOWColls  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of out-of-window collisions detected by this device."
    ::= { device 14 }

deviceNoResources       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of No resource condtions detected by this device."
    ::= { device 15 }

deviceRecBytes  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of bytes detected on the network."
    ::= { device 16 }

deviceGiantFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets longer than 1518 bytes."
    ::= { device 17 }

deviceRestart   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this object is set to 1 the device is restarted."
    ::= { device 18 }

deviceResetCounters     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this object is set to 1, all of the devices counters are reset
         to 0."
    ::= { device 19 }

deviceRedundantCts      OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of redundant circuits available for use."
    ::= { device 20 }

deviceDiscover  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      deprecated      
    DESCRIPTION
        "When this  variable is set to 1 The following events occur:
                (1) The device sends a LINK-UP trap
                (2) The  device sends  a proprietary packet that will
                    cause all other Cabeltron devices on that local
                    network to send a LINK-UP trap."
    ::= { device 21 }

deviceTimeBase  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The  number of seconds used as the interval for performing all of
         the rate alarm checks. The minimum is 10 secs."
    ::= { device 24 }

deviceResetRedundancy   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Setting this object to a 1 will reset redundancy for the entire box."
    ::= { device 25 }

deviceSrcAddrAgingTime  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The number of minutes that a source address is not detected before it
         is removed from the source address table."
    ::= { device 26 }

deviceSrcAddrTraps      OBJECT-TYPE
    SYNTAX      INTEGER
                {
                trapsOff(1),
                trapsOn(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Controls sending of source address related traps."
    ::= { device 27 }

deviceSrcAddrLocked     OBJECT-TYPE
    SYNTAX      INTEGER
                {
                lockOff(1),
                lockOn(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this is set to 2, any source addresses that are detected on
         station ports that are not in the table will cause the port to
         be turned off."
    ::= { device 28 }

deviceEtherOccupiedSlots        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain Ethernet MIM boards.  This field
         is bit encoded (eg. if a bit is set then that board is present).
         For example, a value of 2 indicates that there is an Ethernet board
         in the first MIM slot."
    ::= { device 29 }

deviceTROccupiedSlots   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain managable Token Ring MIM boards.  This
         field is bit encoded (eg. if a bit is set then that board is
         present).  For example, a value of 2 indicates that there is a
         managable Token Ring board in the first MIM slot."
    ::= { device 30 }

deviceFDDIOccupiedSlots OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain FDDI MIM boards.  This field is bit encoded
         (eg. if a bit is set then that board is present).  For example, a
         value of 2 indicates that there is an FDDI board in the first MIM
         slot."
    ::= { device 31 }

deviceRestoreDefaults   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this object is set to 1 the factory defaults are restored.  This,
         however, does not affect the device's IP address."
    ::= { device 32 }

deviceActiveUsers       OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of active users seen by this device."
    ::= { device 33 }

deviceOSIFrames OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with OSI protocol seen by this device."
    ::= { device 34 }

deviceNovellFrames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with NOVELL protocol seen by this device."
    ::= { device 35 }

deviceBanyanFrames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with BANYAN protocol seen by this device."
    ::= { device 36 }

deviceDECNetFrames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with DECNET protocol seen by this device."
    ::= { device 37 }

deviceXNSFrames OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with XNS protocol seen by this device."
    ::= { device 38 }

deviceIPFrames  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with TCPIP protocol seen by this device."
    ::= { device 39 }

deviceCtronFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with Cabletron protocol seen by this device."
    ::= { device 40 }

deviceAppletalkFrames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with Appletalk protocol seen by this device."
    ::= { device 41 }

deviceOtherFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, that do not fall into
         any of the previously listed protocol catagories."
    ::= { device 42 }

device64To127Frames     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, with frame sizes between
         64 and 127 bytes."
    ::= { device 43 }

device128To255Frames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, with frame sizes between
     128 and 255 bytes."
         ::= { device 44 }

device256To511Frames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, with frame sizes between
     256 and 511 bytes."
         ::= { device 45 }

device512To1023Frames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, with frame sizes between
     512 and 1023 bytes."
         ::= { device 46 }

device1024To1518Frames  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames seen by this device, with frame sizes between
     1024 and 1518 bytes."
         ::= { device 47 }

deviceBroadPkts OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of broadcast packets detected on all ports of this device."
    ::= { device 48}

deviceMultPkts  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of multicast packets detected on all ports of this device."
    ::= { device 49}

deviceThdPartyOccupiedSlots     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain Third Party  MIM boards.  This field
         is bit encoded (eg. if a bit is set then that board is present).
         For example, a value of 2 indicates that there is a Third Party
        board in the first MIM slot." 
    ::= { device 51 }

deviceImimOccupiedSlots OBJECT-TYPE
    SYNTAX      INTEGER
        ACCESS  read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain Cabletron Intelligent MIM boards.  This field
         is bit encoded (eg. if a bit is set then that board is present).
         For example, a value of 2 indicates that there is an Intelligent board
         in the first MIM slot."
    ::= { device 52 }

deviceLinkTraps OBJECT-TYPE
    SYNTAX      INTEGER
                {
                trapsOff(1),
                trapsOn(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Controls sending of link related traps."
    ::= { device 54 }


ctIPDefaultFrameType  OBJECT-TYPE
        SYNTAX  INTEGER {
                ethernet(1),
                snap8022(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Defines the default frame type that will be used by the
                device.  A device will understand both frame types and will
                respond based upon the framing type that is learned for
                the given address.  This object defines the type of framing
                that will be used if no framing is known, for example ARP
                requests.

                Setting a value of 8022snap(2) will result in framing
                802.3 - 802.2 - IP packets being generated by default.

                Setting a value of ethernet(1) will result in framing 
                ethernet IP packets by default."
        DEFVAL { ethernet }
        ::= { device 56 }
deviceSrcAddrType  OBJECT-TYPE
        SYNTAX  INTEGER {
                ipHash(1),
                decHash(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        " Selects the hashing algorithm of source addresses, DEC or IP"
        DEFVAL{ ipHash }
        ::= { device 57 }
--          1.3.6.1.4.1.52.1.2.1.1.57

--  Start of Virtual Table
--  SourceAddr object definitions
--  The SourceAddr object section contains objects that can be accessed by
--  source address.  The table index for these objects is the
--  source address of interest.  Each octet within the source address forms
--  a separate sub-identifier.

sourceAddrBoard OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The board number of the port that the supplied source address has
         been found on."
    ::= { sourceAddr 1 }

sourceAddrPort  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The port number of the port that the supplied source address has
         been found on."
    ::= { sourceAddr 2 }

--  End of Virtual Table


--  Redundancy Object Definitions
--  This section defines the objects that are associated with cable level
--  redundancy.  The concepts for this are described in other documentation.
--  There are two types of instance identifiers for redundancy objects.


redundancyPollInterval  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The number of seconds between polls for redundancy."
    ::= { redundancy 1 }

redundancyTestTod       OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The time of day at which the redundant circuits should be tested."
    ::= { redundancy 2 }

redundancyPerformTest   OBJECT-TYPE
    SYNTAX      INTEGER
                {
                performTest(1)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Test the redundant circuit."
    ::= { redundancy 3 }

--  Start of Virtual Table
--  The index for this table is circuitNum, which is of type INTEGER.

redundancyCircuitName   OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The name of the indicated circuit."
    ::= { redundancy 4 }

redundancyRetryCount    OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The number of unanswered polls allowed for the indicated circuit
         before the current connection is declared bad."
    ::= { redundancy 5 }

redundancyNumBPs        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of board/port combinations associated with the indicated
         circuit."
    ::= { redundancy 6 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by circuitNum and circuitBPIndex

redundancyCircuitBoard  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The boards associated with the indicated circuit."
    ::= { redundancy 7 }

redundancyCircuitPort   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The ports associated with the indicated circuit."
    ::= { redundancy 8 }

redundancyCircuitTypes  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The type of each port associated with the indicated circuit."
    ::= { redundancy 9 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by circuitNum

redundancyCircuitNumAddr        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of addresses associated with the indicated circuit."
    ::= { redundancy 10 }

redundancyCircuitMACAddrAdd     OBJECT-TYPE
    SYNTAX      NetworkAddress  
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Adds this ethernet address to the polling list for the indicated
         circuit."
    ::= { redundancy 11 }

redundancyCircuitMACAddrDel     OBJECT-TYPE
    SYNTAX      NetworkAddress 
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Removes this ethernet address from the polling list for the
         indicated circuit."
    ::= { redundancy 12 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by circuitNum and circuitBPIndex

redundancyCircuitMACAddrDisp    OBJECT-TYPE
    SYNTAX      NetworkAddress 
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The ethernet addresses associated with the indicated circuit,
         accessed by index."
    ::= { redundancy 13 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by circuitNum

redundancyCircuitEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enables and disables the indicated circuit."
    ::= { redundancy 14 }

redundancyCircuitReset OBJECT-TYPE
    SYNTAX      INTEGER
                {
                reset(1)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Reset the indicated circuit.  Return all of the associated board
         and ports to NOT-USED, remove associated addresses from the polling
         list, reset the circuit name and retry count to default values."
    ::= { redundancy 15 }


--  ALARM Object definitions

--  This section defines the objects that can cause alarms to be generated.

--  For each section there are 3 sources of alarms:
--      Traffic levels,
--      collision rates (as they relate to traffic), and
--      error rates (also related to traffic).

--  All alarms are qualified by the Devicetimebase (ie. the rates are measured
--  for a particular length of time).

--  Formal definitions for the structure below ALARM are:


devAlrm                 OBJECT IDENTIFIER   ::= { alarm 1 }

bdAlrm                  OBJECT IDENTIFIER   ::= { alarm 2 }

portAlrm                OBJECT IDENTIFIER   ::= { alarm 3 }


--  DevAlrm object defintions
--  This section defines the objects that will control alarms associated with
--  the device.


--  Formal definitions below DevAlrm

devTraffic              OBJECT IDENTIFIER   ::= { devAlrm 1 }

devColls                OBJECT IDENTIFIER   ::= { devAlrm 2 }

devError                OBJECT IDENTIFIER   ::= { devAlrm 3 }

devBroad                OBJECT IDENTIFIER   ::= { devAlrm 4 }

--  DevTraffic Object Definitions
--  This section defines the DevTraffic objects.  These objects control the
--  device level traffic alarm generation.


devTrafficEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of device level traffic traps."
    ::= { devTraffic 1 }

devTrafficThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of packets within the Devicetimebase that will cause
         a traffic alarm."
    ::= { devTraffic 2 }


--  DevColls Object Defintions
--  This section defines the objects that control the device level collision
--  alarm.


devCollsEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of device level collision alarms."
    ::= { devColls 1 }

devCollsThreshold OBJECT-TYPE
    SYNTAX      INTEGER (1..15)
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the number of collisions per good packet
         measured by the device that will generate an alarm."
    ::= { devColls 2 }


--  DevErrorS Object Defintions
--  This section defines the objects that control the device level error alarm.


devErrorEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of device level error alarms."
    ::= { devError 1 }

devErrorThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the percentage of errors per good packet that
         will generate an alarm."
    ::= { devError 2 }

devErrorSource OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The type of error used for the error alarm.

         The integer is a bit encoded version of which errors to include
         in the error sum.  The bits are encoded as follows:

                CRCErrors       -  Bit 0 - Least Significant Bit
                runts           -  Bit 1
                OOWColls        -  Bit 2
                alignErrs       -  Bit 3
                NoResource      -  Bit 4
                Giants          -  Bit 5
        "
    ::= { devError 3 }



--  DevBroad Object Defintions
--  This section defines the objects that control the device level broadcast
--      alarm.

devBroadEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of device level broadcast traps."
    ::= { devBroad 1 }

devBroadThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of broadcast packets within the Devicetimebase
        that will cause a broadcast alarm."
    ::= { devBroad 2 }


--  BdAlrm object definitions
--  This section defines the objects that will control alarms associated with
--  the board.

--  Formal definitions below BdAlrm

bdTraffic       OBJECT IDENTIFIER   ::= { bdAlrm 1 }

bdColls         OBJECT IDENTIFIER   ::= { bdAlrm 2 }

bdError         OBJECT IDENTIFIER   ::= { bdAlrm 3 }

bdBroad         OBJECT IDENTIFIER   ::= { bdAlrm 4 }

--  BdTraffic Object Definitions
--  This section defines the BdTraffic objects.
--  These objects control the board level traffic alarm generation.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

bdTrafficEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of board level traffic traps for this board."
    ::= { bdTraffic 1 }

bdTrafficThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of packets within the Devicetimebase that will cause
         a traffic alarm."
    ::= { bdTraffic 2 }

bdTrafficBdDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable board
                enable (2)      --  Allow for disabling of board
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a board to be disabled on a traffic threshold alarm."
    ::= { bdTraffic 3 }

--  End of Virtual Table


--  BdColls Object Defintions
--  This section defines the objects that control the board level collision
--  alarm.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

bdCollsEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of board level collision alarms."
    ::= { bdColls 1 }

bdCollsThreshold OBJECT-TYPE
    SYNTAX      INTEGER (1..15)
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the number of collisions per good packet
         measured by the board that will generate an alarm."
    ::= { bdColls 2 }

bdCollsBdDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable board
                enable (2)      --  Allow for disabling of board
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a board to be disabled on a collision threshold alarm."
    ::= { bdColls 3 }

--  End of Virtual Table


--  BdErrors Object Defintions
--  This section defines the objects that control the board level error alarm.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

bdErrorEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of board level error alarms."
    ::= { bdError 1 }

bdErrorThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the percentage of errors per good packet
         that will generate an alarm."
    ::= { bdError 2 }

bdErrorSource OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The type of error used for the error alarm.

        The integer is a bit encoded version of which errors to include
        in the error sum.  The bits are encoded as follows:

        CRCErrors       -  Bit 0 Least Significant Bit
        runts           -  Bit 1
        OOWColls        -  Bit 2
        alignErrs       -  Bit 3
        NoResource      -  Bit 4
        Giants          -  Bit 5
        "
    ::= { bdError 3 }

bdErrorBdDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable board
                enable (2)      --  Allow for disabling of board
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a board to be disabled on an error threshold alarm."
    ::= { bdError 4 }

--  End of Virtual Table


--  BdBroad Object Definitions
--  This section defines the BdBroadcast objects.
--  These objects control the board level broadcast alarm generation.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

bdBroadEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory       
    DESCRIPTION
        "Enable the sending of board level broadcast traps for this board."
    ::= { bdBroad 1 }

bdBroadThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of broadcast packets within the Devicetimebase 
        that will cause a broadcast alarm."
    ::= { bdBroad 2 }

bdBroadDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable board
                enable (2)      --  Allow for disabling of board
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a board to be disabled on a broadcast threshold alarm."
    ::= { bdBroad 3 }


--  PortAlrm object definitions
--  This section defines the objects that will control alarms associated with
--  the port.

--  PortAlrm Instance Identifiers

--  There is set of port level alarms per board thus the instance identifiers
--  for PortAlrm objects is the board number.

--  Formal defintions below PortAlrm

portTraffic             OBJECT IDENTIFIER   ::= { portAlrm 1 }

portColls               OBJECT IDENTIFIER   ::= { portAlrm 2 }

portError               OBJECT IDENTIFIER   ::= { portAlrm 3 }

portBroad               OBJECT IDENTIFIER   ::= { portAlrm 4 }

--  PortTraffic Object Definitions
--  This section defines the PortTraffic objects.
--  These objects control the port level traffic alarm generation.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

portTrafficEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of port level traffic traps for this port."
    ::= { portTraffic 1 }

portTrafficThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of packets within the Devicetimebase that will cause
         a traffic alarm."
    ::= { portTraffic 2 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by boardNum and portNum, both of which are INTEGERs

portTrafficPortDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable port
                enable (2)      --  Allow for disabling of port
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a port to be disabled on a traffic threshold alarm."
    ::= { portTraffic 3 }

--  End of Virtual Table


--  PortColls Object Definitions
--  This section defines the objects that control the port level collision 
--  alarm.

--  Start of Virtual Table
--  This table is indexed by boardNum, which is an INTEGER

portCollsEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of port level collsion alarms."
    ::= { portColls 1 }

portCollsThreshold OBJECT-TYPE
    SYNTAX      INTEGER (1..15)
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the number of collisions per good packet
         measured by the port that will generate an alarm."
    ::= { portColls 2 }

-- End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by boardNum and portNum, both INTEGERs

portCollsPortDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable port
                enable (2)      --  Allow for disabling of port
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a port to be disabled on a collision threshold alarm."
    ::= { portColls 3 }

--  End of Virtual Table


--  PortErrors Object Defintions
--  This section defines the objects that control the port level error alarm.

--  Start of Virtual Table
--  This table is indexed by boardNum, an INTEGER

portErrorEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Enable the sending of port level error alarms."
    ::= { portError 1 }

portErrorThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object represents the percentage of errors per good packet
         that will generate an alarm."
    ::= { portError 2 }

portErrorSource OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The type of error used for the error alarm.

        The integer is a bit encoded version of which errors to include
        in the error sum.  The bits are encoded as follows:

        CRCErrors       -  Bit 0 - Least Significant Bit
        runts           -  Bit 1
        OOWColls        -  Bit 2
        alignErrs       -  Bit 3
        NoResource      -  Bit 4
        Giants          -  Bit 5
        "
    ::= { portError 3 }

--  End of Virtual Table

-- Start of Virtual Table
-- This table is indexed by boardNum and portNum, both INTEGERs

portErrorPortDisable    OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable port
                enable (2)      --  Allow for disabling of port
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a port to be disabled on an error threshold alarm."
    ::= { portError 4 }

-- End of Virtual Table


--  PortBroad Object Definitions
--  This section defines the PortBroadcast objects.
--  These objects control the port level broadcast alarm generation.

--  Start of Virtual Table
--  This table is indexed by boardNum, an INTEGER

portBroadEnable OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disable(1),
                enable(2)
                }
    ACCESS      read-write
    STATUS      mandatory       
    DESCRIPTION
        "Enable the sending of port level broadcast alarms."
    ::= { portBroad 1 }

portBroadThreshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The threshold of broadcast packets within the Devicetimebase that
        will cause a broadcast alarm."
    ::= { portBroad 2 }

-- End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by boardNum and portNum, both INTEGERs

portBroadDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                disable(1),     --  Do NOT disable port
                enable (2)      --  Allow for disabling of port
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "Permit a port to be disabled on a broadcast threshold alarm."
    ::= { portBroad 3 }

-- End of Virtual Table


--  RepeaterRev2 Formal declarations

deviceR2                OBJECT IDENTIFIER ::= { repeaterRev2 1}

networkR2               OBJECT IDENTIFIER ::= { repeaterRev2 2}

boardR2                 OBJECT IDENTIFIER ::= { repeaterRev2 3}

portR2                  OBJECT IDENTIFIER ::= { repeaterRev2 4}


--  Token Ring Device object definitions
--  This sections defines the objects associated with Token Ring on the
--      device.
--  The instance ID for these objects are all zero.


tokenRingD              OBJECT IDENTIFIER ::= { deviceR2 3 }

deviceTRPortsOn OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This gives the number of Token Ring ports enabled on this device."
    ::= { tokenRingD 1 }

deviceTRPorts   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This gives the total number of Token Ring ports on this device."
    ::= { tokenRingD 2 }

deviceTRRingPortsOn     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This gives the number of Token Ring ring ports that are enabled."
    ::= { tokenRingD 3 }

deviceTRRingPorts       OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This gives the total number of Token Ring ring ports on this device."
    ::= { tokenRingD 4 }

deviceTRLans    OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This gives the number of Token Rings formed on this device."
    ::= { tokenRingD 5 }

deviceTRBoards  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This returns the number of Token Ring boards on the device."
    ::= { tokenRingD 6 }

deviceTRBoardMap        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slots that contain Token Ring MIM boards.  This field is bit
         encoded (eg. if a bit is set then that board is present).  For
         example, a value of 2 indicates that there is a Token Ring board
         in the first MIM slot."
    ::= { tokenRingD 7 }



--  Board Object Definitions
--  This section will describe the management objects associated with a board.


--  Formal Definitions within Board

commonB         OBJECT IDENTIFIER ::= { boardR2 1}

ethernetB       OBJECT IDENTIFIER ::= { boardR2 2}

tokenRingB      OBJECT IDENTIFIER ::= { boardR2 3}

fDDIB           OBJECT IDENTIFIER ::= { boardR2 4}
 

--  Instance Identifiers for Board Objects

--  The Instance Identifiers for board objects is the number of the slot in
--  the MMAC cage.

--  Common Board Objects

--  Start of Virtual Table
--  This table is indexed by boardIndex

boardIndex      OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slot number of this board."
    ::= { commonB 1 }

boardName       OBJECT-TYPE
    SYNTAX      DisplayString
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The name of the board.  This field will only contain printable ASCII
         characters."
    ::= { commonB 2 }

boardType       OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The type of the MIM. (eg. FOT, TPT, etc).  See appendix A for
         encoding."
    ::= { commonB 3 }

boardTotalPorts OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only     
    STATUS      mandatory
    DESCRIPTION
        "Total number of ports supported on this board."
    ::= { commonB 4 }

boardStatus     OBJECT-TYPE
    SYNTAX      INTEGER
                {
                disabled(1),
                enabled(2)
                }
    ACCESS      read-write
    STATUS      deprecated 
    DESCRIPTION
        "The administrative status of this MIM."
    ::= { commonB 5 }
     
boardPortsOn    OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of operating ports on the board."
    ::= { commonB 6 }

boardOper       OBJECT-TYPE
    SYNTAX      INTEGER {
                operational(1),
                notOperational(2)
                }
    ACCESS      read-only
    STATUS      deprecated
    DESCRIPTION
        "Returns a value indicating whether any of the enabled ports on the
         board are not operational, thereby placing the board in a
         non-operational state."
    ::= { commonB 7 }

boardActiveUsers        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of active users seen on this board."
    ::= { commonB 8 }

--  End of Virtual Table



--  Ethernet Board Objects

--  Start of Virtual Table
--  This table is indexed by boardIndex, an INTEGER

boardTotalPkts  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The total number of packets this board has seen since the last
         reset."
    ::= { ethernetB 1 }

boardErrorPkts  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only    
    STATUS      mandatory
    DESCRIPTION
        "The number of packets that have experienced an error."
    ::= { ethernetB 2 }

boardTransColls OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of transmit collisions this board has detected."
    ::= { ethernetB 3 }

boardRecColls   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of Receive mode collisions this board has detected."
    ::= { ethernetB 4 }

boardAlignErrs  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of misaligned frames this board has detected."
    ::= { ethernetB 5 }

boardCRCErrs    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets with bad CRC detected."
    ::= { ethernetB 6 }

boardRunts      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of runt frames detected by this board."
    ::= { ethernetB 7 }

boardOOWColls   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of out-of-window collisions detected by this board."
    ::= { ethernetB 8 }

boardNoResources        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of times the no resources condition was detected for
         this board."
    ::= { ethernetB 9 }

boardRecBytes   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of bytes detected on this board."
    ::= { ethernetB 10 }

boardGiants     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets longer than 1518 bytes detected on this board."
    ::= { ethernetB 11 }

boardOSIFrames  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with OSI protocol seen by this board."
    ::= { ethernetB 12 }

boardNovellFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames with NOVELL protocol seen by this board."
    ::= { ethernetB 13 }

boardBanyanFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with BANYAN protocol seen by this board."
    ::= { ethernetB 14 }

boardDECNetFrames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with DECNET protocol seen by this board."
    ::= { ethernetB 15 }

boardXNSFrames  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with XNS protocol seen by this board."
    ::= { ethernetB 16 }

boardIPFrames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with TCPIP protocol seen by this board."
    ::= { ethernetB 17 }

boardCtronFrames        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with Cabletron protocol seen by this board."
    ::= { ethernetB 18 }

boardAppletalkFrames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with Appletalk protocol seen by this board."
    ::= { ethernetB 19 }

boardOtherFrames        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, that do not fall into
         any of the previously listed protocol catagories."
    ::= { ethernetB 20 }

board64To127Frames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, with frame sizes between
         64 and 127 bytes."
    ::= { ethernetB 21 }

board128To255Frames     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, with frame sizes between
     128 and 255 bytes."
    ::= { ethernetB 22 }

board256To511Frames     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, with frame sizes between
     256 and 511 bytes."
    ::= { ethernetB 23 }

board512To1023Frames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, with frame sizes between
     512 and 1023 bytes."
    ::= { ethernetB 24 }

board1024To1518Frames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this board, with frame sizes between
     1024 and 1518 bytes."
    ::= { ethernetB 25 }

boardBroadPkts  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of broadcast packets detected on all ports of this board."
    ::= { ethernetB 26 }

boardMultPkts   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of multicast packets detected on all ports of this board."
    ::= { ethernetB 27 }


boardSrcAddrLocked      OBJECT-TYPE
    SYNTAX      INTEGER
                {
                lockOff(1),
                lockOn(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this is set to 2, any source addresses that are detected on
         station port that are not in the table will cause the port to
         be turned off."
    ::= {  ethernetB 31 }

--  End of Virtual Table


--  Token Ring Board Objects

--  Start of Virtual Table
--  This table is indexed by boardIndex, an INTEGER

boardTotalRingPorts     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The total number of ring ports on this board."
    ::= { tokenRingB 1 }

boardTotalStationPorts  OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The total number of station ports on this board."
    ::=  { tokenRingB 2 }

boardModeStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                mgmtMode(1),
                autoMOde(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This describes the mode of this board.  autoMode 
    means the board is using the hardware defaults.  mgmtMode
    means the board is using setting by the user."
    ::= { tokenRingB 3 }

boardTotalRingPortsOn   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of enabled ring ports on this board."
    ::= { tokenRingB 4 }

boardTotalStationPortsOn        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of enabled station ports on this board."
    ::= { tokenRingB 5 }

boardSpeed      OBJECT-TYPE
    SYNTAX      INTEGER {
                fourMHz(4),
                sixteenMhz(16)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The speed of the board.  The board will expect to receive
    data at this speed."
    ::= { tokenRingB 6 }


ringSpeedFault  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                noFaultDetected(1),
                faultDetected(2)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "Data speed of station mismatches configuration speed of board.  Board
         is automatically bypassed."
    ::= { tokenRingB 7 }

boardSpeedFaultPort     OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This object indicates which ring speed detect circuit(s) caused the
         fault, if there was one.  The return code indicates the location on
         the board feeding the speed detect circuit(s).  Ring in means the
         circuit on the back-up path between the ring out port and the ring
         in port.  FNB means the circuit between the ring in port and the FNB.
         NotApplicable means that a ring Speed Fault has not occurred.
         Since more than one circuit can cause the fault, the return code is
         the sum of the following values:
                        1 - FNB
                        2 - RingIn
                        4 - RingOut
                        8 - NotApplicable
        "
    ::= { tokenRingB 8 }

boardFirstRingPort      OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This object defines which port on the board is the first ring port.
         All ring port numbers will be consecutive.  Using this in conjunction
         with BoardRingPorts, all ring port numbers can be determined."
    ::= { tokenRingB 9 }

boardBypassRingPortState        OBJECT-TYPE
    SYNTAX      INTEGER {
                off(1),
                on(2),
                illegal(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object sets and reports the state of the ring bypass relay on
         boards which contain a ring bypass relay.  The ring bypass relay will
         separate only the ring ports from the FNB.  The FNB only bypasses the
         station ports on these boards. The illegal value (3) will return an 
         error status if set."
    ::= { tokenRingB 10 }
 
--  End of Virtual Table


--  Port Object Definitions
--  This section will define the objects associated with ports.


--  Formal Definitions within Port

commonP         OBJECT IDENTIFIER ::= { portR2 1}

ethernetP       OBJECT IDENTIFIER ::= { portR2 2}

tokenRingP      OBJECT IDENTIFIER ::= { portR2 3}

fDDIP           OBJECT IDENTIFIER ::= { portR2 4}


--  Instance Identifiers for Port Objects
--  The instance identifiers for port objects are board# and port#.
--  The format of the port identifier is Board_num.Port_num or B.P.

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs

portIndex       OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The slot number of this port."
    ::= { commonP 1 }

portMediaType   OBJECT-TYPE
    SYNTAX      INTEGER
                {
                bnc(1),   -- Ethernet coaxial connector
                aui(2),   -- Ethernet AUI connector
                tp(3),    -- Ethernet Twisted Pair connector
                tenbt(4), -- Ethernet 10Base-T Twisted Pair connector
                fot(5),   -- Ethernet Fiber Optic connector
                laser(6), -- Ethernet Laser Fiber Optic connector
                stp(7),   -- Token Ring Shielded Twisted Pair connector
                utp(8),   -- Token Ring Unshielded Twisted Pair connector
                fo(9),    -- Token Ring Fiber Optic connector
                otherMedia(10) -- Media type not listed above
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The type of the port. (eg. FOT, TPT, etc)."
    ::= { commonP 2 }

portAdminState  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                off(1),
                on( 2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The administrative status of this port."
    ::= { commonP 3 }

portSourceAddr  OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "A source address that has been seen on this port."
    ::= { commonP 4 }

portOper        OBJECT-TYPE
    SYNTAX      INTEGER {
                notOperational(1),
                operational(2)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "Returns a value indicating whether this port is in an operational
         state."
    ::= { commonP 5 }

portActiveUsers OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of active users seen on this port."
    ::= { commonP 6 }

portName        OBJECT-TYPE
    SYNTAX      DisplayString
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The name of the port.  this field will only contain printable ASCII
        characters."
    ::= { commonP 7 }

--  End of Virtual Table


--  Ethernet Port Objects

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs

portTopologyType        OBJECT-TYPE
    SYNTAX      INTEGER {
                stations(1),
                trunk(2)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The topological type of the port."
    ::= { ethernetP 1 }

portLinkStatus  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                linkSignalInactive(1),
                linkSignalActive(2),
                linkSignalNotSupported(3)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The state of the link signal for this port."
    ::= { ethernetP 2 }

portStatus      OBJECT-TYPE
    SYNTAX      INTEGER
                {
                active(1),
                segmented(2)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The network state of this port."
    ::= { ethernetP 3 }

portTotalPkts   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The total number of packets this port has seen since the last reset."
    ::= { ethernetP 4 }

portErrorPkts   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only    
    STATUS      mandatory
    DESCRIPTION
        "The number  of packets  that have experienced an error."
    ::= { ethernetP 5 }

portXmitColls   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of Transmit mode collisions this port has detected."
    ::= { ethernetP 6 }

portRecColls    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of Receive mode collisions this port has detected."
    ::= { ethernetP 7 }

portAlignErrs   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of misaligned frames this port has detected."
    ::= { ethernetP 8 }

portCRCErrs     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of packets with bad CRC detected."
    ::= { ethernetP 9 }

portRunts       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of runt frames detected by this port."
    ::= { ethernetP 10 }

portOOWColls    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of out-of-window collisions detected by this port."
    ::= { ethernetP 11 }

portNoResorces  OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of  times the no resource condition is detected on this
         port."
    ::= { ethernetP 12 }

portRecBytes    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of bytes detected on the network."
    ::= { ethernetP 13 }

portGiants      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The number of frames longer than 1518 bytes detected on this port."
    ::= { ethernetP 14 }

portRedundCrt   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The redundant circuit with which this port is associated."
    ::= { ethernetP 15 }

portRedundType  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                notUsed(1),     --  indicates that the port is not used
                                --  in circuit
                primary(2),
                backup(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The type of port this port is in the redundant circuit.  The port
        must be associated with a redundant circuit first, using the object
        portRedundCrt."
    ::= { ethernetP 16 }

portRedundStatus        OBJECT-TYPE
    SYNTAX      INTEGER
                {
                notUsed(1),     --  indicates that the port is not used
                                --  in circuit
                active(2),
                inactive(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The current state of this port is in the redundant circuit.  The port
        must be associated with a redundant circuit first, using the object
        portRedundCrt."
    ::= { ethernetP 17 }

portForceTrunkType      OBJECT-TYPE
    SYNTAX      INTEGER
                {
                notForced(1),
                forced(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This variable forces a port to be a trunk port."
    ::= { ethernetP 18 }

portOSIFrames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with OSI protocol seen by this port."
    ::= { ethernetP 19 }

portNovellFrames        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with NOVELL protocol seen by this port."
    ::= { ethernetP 20 }

portBanyanFrames        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with BANYAN protocol seen by this port."
    ::= { ethernetP 21 }

portDECNetFrames        OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with DECNET protocol seen by this port."
    ::= { ethernetP 22 }

portXNSFrames   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with XNS protocol seen by this port."
    ::= { ethernetP 23 }

portIPFrames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with TCPIP protocol seen by this port."
    ::= { ethernetP 24 }

portCtronFrames OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with Cabletron protocol seen by this port."
    ::= { ethernetP 25 }

portAppletalkFrames     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames with Appletalk protocol seen by this port."
    ::= { ethernetP 26 }

portOtherFrames OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, that do not fall into
         any of the previously listed protocol catagories."
    ::= { ethernetP 27 }

port64To127Frames       OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, with frame sizes between
         64 and 127 bytes."
    ::= { ethernetP 28 }

port128To255Frames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, with frame sizes between
     128 and 255 bytes."
    ::= { ethernetP 29 }

port256To511Frames      OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, with frame sizes between
     256 and 511 bytes."
    ::= { ethernetP 30 }

port512To1023Frames     OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, with frame sizes between
     512 and 1023 bytes."
    ::= { ethernetP 31 }

port1024To1518Frames    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
        "The number of frames seen by this port, with frame sizes between
     1024 and 1518 bytes."
    ::= { ethernetP 32 }

portBroadPkts   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of broadcast packets detected on this port."
    ::= { ethernetP 33 }

portMultPkts    OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "The sum of multicast packets detected on this port."
    ::= { ethernetP 34 }

portSrcAddrLocked       OBJECT-TYPE
    SYNTAX      INTEGER
                {
                lockOff(1),
                lockOn(2)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "If this is set to 2, any source addresses that are detected on
         station ports that are not in the table will cause the port to
         be turned off."
    ::= { ethernetP 38 }

--  End of Virtual Table


--  Token Ring Port Objects
--  Token Ring Port Objects are further broken down into station objects and
--  Ring-In/Ring-Out objects.  The formal definitions are:


stationP        OBJECT IDENTIFIER ::= { tokenRingP 1 }

ringP           OBJECT IDENTIFIER ::= { tokenRingP 2 }

ringPort2       OBJECT IDENTIFIER ::= { tokenRingP 3 }

commonRP        OBJECT IDENTIFIER ::= { ringPort2 1 }

autowrapRP      OBJECT IDENTIFIER ::= { ringPort2 2 }

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs

stationPortLinkStatus   OBJECT-TYPE
    SYNTAX      INTEGER
                {
                linkSignalInactive(1),
                linkSignalActive(2)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "When station is supplying phantom current the Link Signal is active.
         When there is no phantom current the Link Signal is inactive."
    ::= { stationP 1 }

stationPortLinkStateTime        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The amount of in seconds which have  elapsed since the station port
         last changed state.  Note:  setting this to zero will clear the time."
    ::= { stationP 2 }

--  End of Virtual Table


--  This section will define the objects associated with Ring In and Ring
--  Out ports, e.g. trmim10R.

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs

ringPortLinkStatus      OBJECT-TYPE
    SYNTAX      INTEGER
                {
                off(1),         --  wrapped
                on(2)           --  active
                }
    ACCESS      read-only
    STATUS      obsolete
    DESCRIPTION
        "Reports the link state of a ring port."
    ::= { ringP 1 }

ringPortLinkStateTime   OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      obsolete
    DESCRIPTION
        "Reports the time (in seconds) since the ring port's link 
    state changed."
    ::= { ringP 2 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs

commonRPcapabilities    OBJECT-TYPE
    SYNTAX      INTEGER
                {
                nonAutowrap(1),
                autowrap(2),
                selectable(3)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This object returns a code indicating that the queried ring port
         is nonautowrap, autowrap or selectable."
    ::= { commonRP 1 }

--  End of Virtual Table

--  Start of Virtual Table
--  This table is indexed by boardIndex and portIndex, both INTEGERs    

autowrapRPFaultStatus   OBJECT-TYPE
    SYNTAX      INTEGER
                {   
                faultUndetectable(1),
                noFaultDetected(2),
                faultDetected(3)
                }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
        "This object reports the wire fault of an autowrappable ring port."
    ::= { autowrapRP 1 }

autowrapRPFaultStateTime        OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object reports the amount of time in time ticks since the ring
         port fault state last changed.  Writing zero to this object resets
         the time.  If a zero is read, it means either zero time ticks have
         passed or the ring port is nonautowrap."
    ::= { autowrapRP 2 }

autowrapRPSelectedType  OBJECT-TYPE
    SYNTAX      INTEGER
                {
                unselectable(1),
                stp(2),                 -- sheilded twisted pair
                fo(3)                   -- Fiber Optic
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object indicates the media type of the indicated ring port on
         some boards.  Some boards provide both STP and fiber optic ring ports.
         The unselectable value will return an error if set.  A set of STP or FO
         for a non-selectable ring port will not do anything, i.e. the status 
         of normal is returned."
    ::= { autowrapRP 3 }

autowrapRPPhantomCurrent        OBJECT-TYPE
    SYNTAX      INTEGER
                {
                noPhantomAvailable(1),
                activatePhantom(2),
                deactivatePhantom(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object tells the board to turn on phantom current for the ring
         port and look for wire faults.  NoPhantomAvailable will return an 
         error if set. A set of activatePhantom or deactivatePhantom for a 
         non-autowrap ring port will not do anything, i.e. the status of 
         normal is returned."
    ::= { autowrapRP 4 }

--  End of Virtual Table

--  Product specific Objects
--  For each of the individual repeaters/bridges there are several objects
--  that particular to that product.


fNB             OBJECT IDENTIFIER ::= { subSysMMAC 1 }


--  FNB Objects:

--  Start of Virtual Table
--  This table is indexed by boardIndex, an INTEGER

connectedLeft   OBJECT-TYPE
    SYNTAX      INTEGER {
                detached(1),
                attached(2),
                faulted(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The Connected Left board (board n + 1) has the following states:

                Detached == 1  (Management (only management) detached,
                               read/write).
                Attached == 2  (Management/AutoMode  attached, read/write).
                Faulted  == 3  (Management/AutoMode tried to attach but
                               failed READ ONLY).
        "
    ::= { fNB 1 }

connectedRight  OBJECT-TYPE
    SYNTAX      INTEGER {
                detached(1),
                attached(2),
                faulted(3)
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "The Connected Right board (board n - 1) has the following states:

                Detached == 1  (Management (only management) detached,
                               read/write).
                Attached == 2  (Management/AutoMode attached, read/write ).
                Faulted  == 3  (Management/AutoMode tried to attach but
                               failed READ ONLY).
        "
    ::= { fNB 2 }

boardBypassState        OBJECT-TYPE
    SYNTAX      INTEGER {
                off(1),         --  not bypassed
                on(2)           --  bypassed
                }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This object indicates that the board is in the bypassed state
    when it is ON.  Bypassed means the board is NOT attached to the 
    FNB."
    ::= { fNB 3 }



-- TrapTypes 
-- 
--      This section  will describe  the trap  types  that  the
-- repeater section  of the  IRM3 can  generate. These  are not
-- objects, but  Object identifers used to indicate the specfic
-- trap. They  are taken  from the  object space  and are  thus
-- documented here.
-- 
--      The   SNMP    protocol   provides   a   mechanism   for
-- asynchronusly notifying  management stations  of significant
-- changes in  the network.  This mechanism  is the  SNMP  trap
-- message. This  document will describe the general format for
-- all trap  messages that  Cabletron products will generate as
-- well as the specific traps that the will be generated by the
-- IRM3.
-- 
--  Trap Formats
-- 
--      The  SNMP  trap  messages  are  composed  of  two  user
-- definable areas: the specific trap type and the VarBindings
-- (eg. the interesting information). The specific trap type is
-- an INTEGER  that is used to determine the specific trap that
-- has occurred. The "interesting information" contains a group
-- of objects  identifiers (OID)  and their values that provide
-- information about the trap.
-- 
-- 
-- Trap Description
-- 
-- PortSegmenting 
-- 
-- Specfic Trap Type Code - 0x101
-- 
--      When a  port goes from operational to segmented, a trap
-- will be  generated. For  these purposes, the port state will
-- be sampled  every XXX seconds, thus it will be statistically
-- possible to miss oscillating circuits.
-- 
--      The interesting information will include:
--           - Board number
--           - Port number
-- 
-- Trap Description
-- 
--  PortUnsegementing 
-- Specfic Trap Type Code - 0x102
-- 
--      When it  is detected  that a  previously segmented port
-- has gone  operational, a  trap will  be generated.   This is
-- also sampled,  thus a  trap may  not be  generated for  each
-- transition.
-- 
--      The interesting information will include:
--           - Board number
--           - Port number
-- 
-- 
-- 
-- Trap Description
-- 
--  PortLinkUp 
-- 
-- Specfic Trap Type Code - 0x103
-- 
--      This trap  will be generated when it is determined that
-- MAU has  been attached to the MMAC. This is only appropriate
-- for MIMs that support the concept of a link state.
-- 
--      The interesting information will include:
--           - Board number
--           - Port number
-- 
-- Trap Description
-- 
--  PortLinkDown 
-- 
-- Specfic Trap Type Code - 0x104
-- 
--      This trap  will be generated when a previously attached
-- MAU  is  removed  or  powered  down.  Again,  this  is  only
-- appropriate for MIM's that support link state.
-- 
--      The interesting information will include:
--           - Board number
--           - Port number
-- 
-- Trap Description
--  NewSourceAddress 
-- Specfic Trap Type Code - 0x105
-- 
--      This trap  will be  generated when the MMAC detects the
-- existence of a new source address on one of it's ports.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Port number
--           - The new source address
-- 
-- Trap Description
--  SourceAddressTimeout 
-- 
-- Specfic Trap Type Code - 0x106
-- 
--      This trap  will indicate that the MMAC has not detected
-- a packet  generated by  this source address within a certain
-- timeout.
-- 
-- 
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Port number
--           - Source address that timed out.
-- 
-- Trap Description
-- 
--  BoardRemoval 
-- 
-- Specfic Trap Type Code - 0x107
-- 
--      This trap  will be generated when the MMAC detects that
-- MIM has been removed.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           
-- Trap Description
--  BoardInsertion 
-- 
-- Specfic Trap Type Code - 0x108
-- 
-- 
--      This trap  will be  generated when  the MMAC determines
-- that a new board has been inserted.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Board type
-- 
-- Trap Description
--  ActivePortInRedundantCircuitFailed 
-- 
-- Specfic Trap Type Code - 0x109
-- 
--      This trap  will be  generated when the active port in a
-- redundant circuit has failed polling. This will indicate the
-- activation of redundancy.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Port number
--           - Circuit number
-- 
-- Trap Description
--  RedundantPortActivated 
-- 
-- Specfic Trap Type Code - 0x10a
-- 
-- 
-- 
--      This trap  indicates that a new port has been activated
-- in a  redundant circuit.  This does  NOT indicate  that this
-- port is  usable, but  is being tested. If the port fails the
-- above (3.9) trap will be generated.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Port number
--           - Circuit number
-- 
-- Trap Description
--  RedundantPortTestFailed 
-- 
-- Specfic Trap Type Code - 0x10b
-- 
-- 
-- 
--      This trap will be generated when the MMAC executes it's
-- periodic redundancy diagnostics and finds on of the ports in
-- a redundant  circuit  has  failed.  This  message  will  not
-- indicate that  redundancy has  been activated, just that the
-- port has failed and should be fixed before it is needed.
-- 
--      The interesting information will include:
-- 
--           - Board number
--           - Port number
--           - Circuit number
-- 
-- Trap Description
--  deviceTrafficThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x10c
-- 
--      This trap  will be  generated when  the  traffic  (good
-- packets per  time interval)  has been  exceed for the entire
-- MMAC.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase value
-- 
-- Trap Description
--  deviceErrorThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x10d
-- 
--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets for a particular interval for the entire MMAC.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - selected error type
--           - timebase
-- 
-- Trap Description
--  deviceCollsionThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x10e
-- 
--      This trap  will be  generated when  collsions exceed  a
-- threshold percentage  of the  good packets  for a particular
-- interval for the entire MMAC.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase
-- 
-- Trap Description
--  BoardTrafficThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x10f
-- 
--      This trap  will be  generated when  the  traffic  (good
-- packets per  time interval) has been exceed for a particular
-- MIM.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase value
--           - board number
-- 
-- Trap Description
--  BoardErrorThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x110
-- 
--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets for a particular interval for a particular MIM.
-- This will most likely indicate a bad MIM.
-- 
--      The interesting information will include:
--           - threshold value
--           - selected error type
--           - timebase
--           - Board number
-- 
-- Trap Description
--  BoardCollisionThresholdExceeded 
-- 
-- 
-- 
-- Specfic Trap Type Code - 0x111
-- 
-- 
--      This trap  will be  generated when  collisions exceed a
-- threshold percentage  of the  good packets  for a particular
-- interval for a particular MIM.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase
--           - Board number
-- 
-- Trap Description
--  PortTrafficThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x112
-- 
-- 
--      This trap  will be  generated when  the  traffic  (good
-- packets per  time interval) has been exceed for a particular
-- port.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase value
--           - board number
--           - port number
-- 
-- Trap Description
--  PortErrorThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x113
-- 
-- 
-- 
--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets  for a  particular interval  for  a  particular
-- port.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - selected error type
--           - timebase
--           - board number
--           - port number
-- 
-- 
-- Trap Description
--  PortCollisionThresholdExceeded 
-- 
-- Specfic Trap Type Code - 0x114
-- 
--      This trap  will be  generated when  collisions exceed a
-- threshold percentage  of the  good packets  for a particular
-- interval for a particular port.
-- 
--      The interesting information will include:
-- 
--           - threshold value
--           - timebase
--           - board number
--           - port number
-- 
-- Trap Description
--  PortTypeChanged
-- 
-- Specfic Trap Type Code - 0x115
-- 
--      This trap indicates that a port has changed from a 
-- station port to a link port or vice versa.
-- 
--      The interesting information is:
-- 
--      - Board number
--      - Port Number
--      - New type value
-- 
-- Trap Description
--  LockSTATUSChanged
-- 
-- Specfic Trap Type Code - 0x116
-- 
--      This trap is generated when the status of the address lock 
-- changes.
-- 
--      The interesting information is:
-- 
--      - New lock status
-- 
-- 
-- Trap Description
--  PortSecurityViolation
-- 
-- Specfic Trap Type Code - 0x117
-- 
--      This trap is generated when a source address other than those
-- locked to a port is seen.
-- 
--      The interesting information is:
-- 
--      - Board number
--      - Port Number
--      - Violating Address
-- 
-- 
-- Trap Description
--  PortViolationReset
-- 
-- Specfic Trap Type Code - 0x118 
-- 
--      This trap is generated when management intervention has 
-- reset a port after a violation has occured.
-- 
--      The interesting information is:
--      
--      - Board Number
--      - Port Number
-- 
-- Trap Description
--  EnvTempWarm
-- 
-- Specfic Trap Type Code - 0x119
-- 
--      This trap is generated when the device detects that the temperature
-- within the device has reached a WARM condition.
-- 
-- 
--      The interesting information is:
-- 
--      - Board Number
-- 
-- 
-- Trap Description
--  EnvTempHot
-- 
-- Specfic Trap Type Code - 0x11A
-- 
--      This trap is generated when the device detects that the temperature
-- within the device has reached a HOT condition.

--      The interesting information is:
-- 
--      - Board Number
-- 
-- 
-- Trap Description
--  EnvTempNormal
-- 
-- Specfic Trap Type Code - 0x11C
-- 
--      This trap is generated when the device detects that the temperature
-- within the device has returned to a NORMAL state.
-- 
--      The interesting information is:
-- 
--      - Board Number
-- 
-- 
-- Trap Description
--  EnvVoltageLow
-- 
-- Specfic Trap Type Code - 0x11B
-- 
--      This trap is generated when a board detects that it's power supply
-- voltage is LOW.
-- 
-- 
--      The interesting information is:
-- 
--      - Power Supply Number
-- 

-- Trap Description
--  EnvVoltageNormal
-- 
-- Specfic Trap Type Code - 0x11D
-- 
--      This trap is generated when the device detects that the system voltage
--  has returned to a NORMAL state.
-- 
-- 
--      The interesting information is:
-- 
--      - None
-- 

-- Trap Description
--  EnvFanFailure
--
-- Specific Trap Type Code - 0x11E
--
-- This trap is generated when the device detects that one or more fans in
-- the chassis have failed.
--
--
-- The interesting information is:
--
-- - None
--

-- Trap Description
--  EnvFanNormal
--
-- Specific Trap Type Code - 0x11F
--
-- This trap is generated when the device detects that all fans in the chassis
-- are functional.
--
--
-- The interesting information is:
--
-- - None
--

-- Trap Description
--  DeviceBroadcastThresholdExceeded
--
-- Specific Trap Type Code - 0x120
--
--      This trap is generated when the broadcast packets (per time 
-- interval) have exceeded the threshold for the entire MMAC.
--
-- The Interesting Information is:
--      devBroadThreshold { devBroad 2 }
--      devTimeBase       { device 24  }


-- Trap Description
--  BoardBroadcastThresholdExceeded
--
-- Specific Trap Type Code - 0x121
--
--      This trap is generated when the broadcast packets (per time 
-- interval) have exceeded the threshold for the given board.
--
-- The Interesting Information is:
--      bdBroadThreshold { bdBroad 2 }
--      devTimeBase      { device 24  }
--      boardIndex       { commonB 1 }
--


-- Trap Description
--  PortBroadcastThresholdExceeded
--
-- Specific Trap Type Code - 0x122
--
--      This trap is generated when the broadcast packets (per time 
-- interval) have exceeded the threshold for the given port.
--
-- The Interesting Information is:
--      portBroadThreshold { portBroad 2 }
--      devTimeBase        { device 24  }
--      boardIndex         { commonB 1 }
--      portIndex          { commonP 1 }
--


-- Trap Description
--  BoardLockSTATUSChanged

-- Specific Trap Type Code - 0x134

--   This trap is generated when the status of the address lock 
-- changes for a certain board.

-- The Interesting Information is:

--      BoardIndex { rptrPortGrpMgmtEntry 1 }
--      BoardSrcAddrLockState { rptrPortGrpSrcAddrEntry 3  }


-- Trap Description
--  PortLockSTATUSChanged

-- Specific Trap Type Code - 0x135

--   This trap is generated when the status of the address lock 
-- changes for a certain port.

-- The Interesting Information is:

--      BoardIndex { rptrPortGrpMgmtEntry 1 }
--      PortIndex { rptrPortMgmtEntry 1 }
--      PortSrcAddrLockState { rptrPortSrcAddrEntry 6 }


-- Token Ring Traps
--
--   Trap Description
--
--      stationLinked-- 
--        
--      Specific Trap Type Code - 0x0201
--
--      This trap is generated in the event that a station port detects a
--  link.  The interesting information included with this trap is the
--  board index and port index of the station port which detects link.
--
--   Trap Description
--
--      stationUnlinked
--
--      Specific Trap Type Code - 0x0202
--
--      This trap is generated in the event that a station port detects a 
--  link has been removed.  The interesting information included with this
--  trap is the board index and port index of the station port which detects
--  that the link has been removed.

--   Trap Description
--    
--      ringSpeedFault
--
--      Specific Trap Type Code - 0x0203
--
--      This trap is generated when speed of the board differs from speed of
--   the data passing through the board.  The interesting information included
--   with this trap is the board index of the board which detects the ring 
--   speed fault.

--   Trap Description
--
--      ringSpeedFaultCleared
-- 
--      Specific Trap Type Code - 0x0204
--
--      This trap is generated when ring speed fault has been corrected.  The
--   interesting information included with this trap is the board index of the
--   board which detects the ring speed fault condition has been removed.

--   Trap Description
--
--      autoWrapWireFault
--
--      Specific Trap Type Code - 0x0205
--
--      This trap is generated when the Shielded Twisted Pair ring port has
--   detected that the phantom current asserted on it does not detect the 
--   correct voltage of the received phantom current.  The interesting 
--   information included with this trap is the board index and the port index
--   of the ring port which detects the autoWrapWireFault.

--   Trap Description
--
--      autoWrapWireFaultCleared
--
--      Specific Trap Type Code - 0x0206
--
--      This trap is generated when the autoWrapWireFault conditions have been
--   removed.  The interesting information included with this trap is the board
--   index and the port index of the ring port which detects that the 
--   autoWrapWireFault conditions have been removed.
--
--
--             Appendix A - Media type values
-- 
-- Board Type          Value
-- 
-- Management Modules
--      IRM-2                           0xB0
--      IRBM                            0xB1
--      IRM-3                           0xB2
--      TRMBM-R                         0xB4
--      TRMBM-S                         0xB5
--      EFDMIM                          0xB6
--      ETBMIM                          0xB7
--      TRBMIM                          0xB8
--      TRMM                            0xBB
--      ETWMIM                          0xBD
--      TRMMIM                          0xBE
--      MiniMMAC                        0x10010
--      MRXI                            0x30043 
--      MRXI-2                          0x30042
--      MRXI-28                         0x300A0
-- 

--      Mim Types
--      THNMIM                          0x10 or 0x50
--      MT8MIM                          0xA0
--      FOTMIM (6 ports)                0xE0
--      FOTMIM (12 ports)               0xC0
--      TPTMIM                          0xD0

--      TPMIM-T                         0x42
--      TPMIM-T1                        0x41
--      TPMIM-T3                        0x43

--      TPMIM-24                        0x60
--      TPMIM-22                        0x61
--      TPMIM-34                        0x62
--      TPMIM-32                        0x63

--      FOMIM-18                        0x90
--      FOMIM-12                        0x92
--      FOMIM-16                        0x93
--      FOMIM-28                        0x94
--      FOMIM-22                        0x96
--      FOMIM-26                        0x97
--      FOMIM-38                        0x98
--      FOMIM-32                        0x9A
--      FOMIM-36                        0x9B

--      TPRMIM-36                       0x70
--      TPRMIM-33                       0x71
--      CXRMIM                          0x72
--      FORMIM-22                       0x73


--      TRMIM-12                        0x30
--      TRMIM-10R                       0x31
--      TRMIM-10RA                      0x131  (will be displayed as TR-10R)
--      TRMIM-22                        0x32
--      TRMIM-20R                       0x33
--      TRMIM-20RA                      0x133  (will be displayed as TR-20R)

--      TRMIM-24A                       0x36
--      TRMIM-22A                       0x37

--      FTRMIM-28                       0x38
--      FTRMIM-22                       0x39
--      FTRMIM-26                       0x3B
--      TRMIM-34A                       0x3C
--      TRMIM-32A                       0x3D
--      TRMIM-44A                       0x3E
--      TRMIM-42A                       0x3F

--      TRRMIM-A                        0x3A
--      TRRMIM-2A                       0x13A
--      TRRMIM-4A                       0x23A


--      FDMMIM-00                       0x23
--      FDMMIM-04                       0x22
--      FDMMIM-16                       0x21
--      FDMMIM-26                       0x20
--      FDMMIM-00S                      0x27
--      FDMMIM-04S                      0x26
--      FDMMIM-16S                      0x25
--      FDMMIM-26S                      0x24
--      FDCMIM-04                       0x2B    
--      FDCMIM-08                       0x2A    
--      FDCMIM-16                       0x2F    
--      FDCMIM-12                       0x2D    
--      FDCMIM-26                       0x2C    
--      FDCMIM-22                       0x28    


--      Third party Mims

--      CISCO Ethernet to Ethernet Router Mim                   0x01
--      Xyplex 16 port terminal server. ETSMIM                  0x02
--      SGI CPU MIM                                             0x03
--      CAYMAN Appletalk to Ethernet Router. GATORMIM CS        0x04
--      NOVELL LANTERN ethernet SNMP Monitor. LANTERMIM         0x05
--      CISCO Ethernet to Ethernet Router Mim. CRM-L            0x06
--      CISCO Ethernet to WAN Router Mim. CRM-S                 0x07
--      Cayman 1 GATOR STAR GX.M                                0x08
--      Cayman 2                                                0x09
--      Cayman 3                                                0x0A
--      Cayman 4                                                0x0B


-- Multi-Port Interfaces Modules
--      MPIM-X                          0x20000
--      MPIM-A                          0x20001
--      MPIM-C                          0x20002
--      MPIM-T                          0x20003
--      MPIM-F2                         0x20004
--      MPIM-F1                         0x20005
--      MPIM-T1                         0x20006
--      MPIM-B                          0x20007 - BLANK
-- 
-- 
-- Single-Port Interface Modules
-- 

--      SPIM-C                          0x20002
--      SPIM-T                          0x20003
--      SPIM-F2                         0x20004
--      SPIM-F1                         0x20005
--      SPIM-T1                         0x20006
--      SPIM-B                          0x20007 - BLANK
-- 
--  

END