The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing A3Com-System-r8-MIB.
Vendor: | 3Com |
---|---|
Mib: | A3Com-System-r8-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- This MIB is for 3Com intermediate systems to provide general -- systems level information. -- The 3Com Enterprise Products Proprietary MIB Extensions -- Copyright 3Com Corporation, 1993. All rights reserved. A3Com-System-r8-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI DisplayString FROM RFC1213-MIB MacAddress FROM RFC1286-MIB TRAP-TYPE FROM RFC-1215 OBJECT-TYPE FROM RFC-1212; -- -- This MIB is for General 3Com Systems. -- a3Com OBJECT IDENTIFIER ::= { enterprises 43 } brouterMIB OBJECT IDENTIFIER ::= { a3Com 2 } a3ComSys OBJECT IDENTIFIER ::= { brouterMIB 13 } a3ComSysID OBJECT IDENTIFIER ::= { a3ComSys 1 } a3ComChip OBJECT IDENTIFIER ::= { a3ComSys 2 } a3ComMem OBJECT IDENTIFIER ::= { a3ComSys 3 } a3ComBrd OBJECT IDENTIFIER ::= { a3ComSys 4 } a3ComAudit OBJECT IDENTIFIER ::= { a3ComSys 5 } a3ComTime OBJECT IDENTIFIER ::= { a3ComSys 6 } a3ComAccCtl OBJECT IDENTIFIER ::= { a3ComSys 7 } a3ComSysMisc OBJECT IDENTIFIER ::= { a3ComSys 8 } a3ComFW OBJECT IDENTIFIER ::= { a3ComSys 9 } a3ComBoot OBJECT IDENTIFIER ::= { a3ComSys 10 } a3ComLastBoot OBJECT IDENTIFIER ::= { a3ComSys 11 } a3ComFileMgmt OBJECT IDENTIFIER ::= { a3ComSys 12 } a3ComFileList OBJECT IDENTIFIER ::= { a3ComFileMgmt 9 } a3ComFmCksum OBJECT IDENTIFIER ::= { a3ComFileMgmt 10 } a3ComFileInfo OBJECT IDENTIFIER ::= { a3ComFileMgmt 11 } a3ComRecovery OBJECT IDENTIFIER ::= { a3ComSys 13 } RowStatus ::= INTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) } --This data type, which has the same semantics as the rowStatus --textual convention used in SNMPv2, is used to add and --delete entries from a table. --The tables in this MIB allow a subset of the functionality --provided by the rowStatus textual convention. In particular --row creation is allowed using only the createAndGo method. --That is, when adding entries to this table, this object --must be set to createAndGo(4). The instance identifier --for this object will define the values of the columns --that make up the index. --In the same PDU, the appropriate remaining columns --of that row must be set as well. The agent --will immediately set the value of this object to --active(1) if the row is correct. If not, the agent --will refuse the SET request and return an --error code. --To modify an existing entry, it must be removed --and another entry with the desired changes added. --To remove an entry, set the value of this object --to destroy(6). -- -- The ID Group -- a3sysVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text string containing general system information, including the package identifier and the system's software release number." ::= { a3ComSysID 1 } a3sysPlatformDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text string describing the physical platform or chassis on which the system is running." ::= { a3ComSysID 2 } a3sysPlatformID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "An OID defining the system platform." ::= { a3ComSysID 3 } a3sysCallerID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A text string defined by the user. This string can be used by a system running PPP as a unique identification of itself to its peer when communicating over a PPP link. " ::= { a3ComSysID 4 } -- -- The Chip group -- a3sysChipTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysChipEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about the chips that are used in the CPU board of the system." REFERENCE "NetBuilderII Ref. Guide: System Service Parameters: CPUboardInfo" ::= { a3ComChip 1 } a3sysChipEntry OBJECT-TYPE SYNTAX A3sysChipEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table contains information about one of the chips installed in the CPU module." REFERENCE "NetBuilderII Ref. Guide: System Service Parameters: CPUboardInfo" INDEX { a3sysChipSlotIndex, a3sysChipIndex } ::= { a3sysChipTable 1 } A3sysChipEntry ::= SEQUENCE { a3sysChipSlotIndex INTEGER, a3sysChipIndex INTEGER, a3sysChipName DisplayString, a3sysChipDescr DisplayString } a3sysChipSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a specific slot (and hence, a specific board). All the Chips described with this index are located on a single board." ::= { a3sysChipEntry 1 } a3sysChipIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a specific chip on the board identified by a3sysChipSlotIndex." ::= { a3sysChipEntry 2 } a3sysChipName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This provides a readable name for the chip." ::= { a3sysChipEntry 3 } a3sysChipDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This provides general information about the chip, including its part number and revision number." ::= { a3sysChipEntry 4 } -- -- The Memory group -- a3sysMemTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysMemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about the system's memory configurations." ::= { a3ComMem 1 } a3sysMemEntry OBJECT-TYPE SYNTAX A3sysMemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table contains information about a specific memory component. The information includes the memory type, its starting address and its size." INDEX { a3sysMemSlotIndex, a3sysMemIndex} ::= { a3sysMemTable 1 } A3sysMemEntry ::= SEQUENCE { a3sysMemSlotIndex INTEGER, a3sysMemIndex INTEGER, a3sysMemType INTEGER, a3sysMemStartAdd INTEGER, a3sysMemSize INTEGER } a3sysMemSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the slot (and hence the board) that supports the memory elements identified by this entry in the table." ::= { a3sysMemEntry 1 } a3sysMemIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into this table. Each memory component is identified by a unique value of this object. This is specific to the board identified by a3sysMemSlotIndex." ::= { a3sysMemEntry 2 } a3sysMemType OBJECT-TYPE SYNTAX INTEGER { other (1), ram-instruction (2), ram-data (3), ram-shared (4), rom-fprom (5), rom-eeprom (6), ram-total (7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the type of the memory component." ::= { a3sysMemEntry 3 } a3sysMemStartAdd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The starting address of the memory component." ::= { a3sysMemEntry 4 } a3sysMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of the memory component, in bytes." ::= { a3sysMemEntry 5 } -- -- The Board group -- -- This group contains information about all the boards installed -- on the system. This includes IO boards and CPU boards. -- -- (The objects relating to boards may migrate to the Chassis MIB -- once it's defined.) -- a3sysSlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of slots (empty or not) in the system" ::= { a3ComBrd 1 } a3sysBrdTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysBrdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the IO boards in this system." ::= { a3ComBrd 2 } a3sysBrdEntry OBJECT-TYPE SYNTAX A3sysBrdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information for each IO board in the system." INDEX { a3sysSlotIndex } ::= { a3sysBrdTable 1 } A3sysBrdEntry ::= SEQUENCE { a3sysSlotIndex INTEGER, a3sysBrdDescr DisplayString, a3sysBrdPathCapacity INTEGER, a3sysBrdOID OBJECT IDENTIFIER, a3sysBrdReset INTEGER, a3sysBrdFwVers OBJECT IDENTIFIER } a3sysSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot number which this board occupies." ::= { a3sysBrdEntry 1 } a3sysBrdDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This contains general information about the Board, including the model type, the serial number, and manufacturing information." ::= { a3sysBrdEntry 2 } a3sysBrdPathCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of physical ports supported by this board." ::= { a3sysBrdEntry 3 } a3sysBrdOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The Object Identifier assigned to this Board." ::= { a3sysBrdEntry 4 } a3sysBrdReset OBJECT-TYPE SYNTAX INTEGER { other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to reset(2), the IO board in the slot specified by this instance identifier of this object is reset. If a GET request is sent for the value of this object, other(1) is returned." ::= { a3sysBrdEntry 5 } a3sysBrdFwVers OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object returns the version of the firmware that is running on this network interface board. A list of all the OIDs assigned to 3Com router firmware can be ftp'd from ftp.3com.com." ::= { a3sysBrdEntry 6 } -- -- Audit trail group -- a3sysAuditTrailType OBJECT-TYPE SYNTAX INTEGER { local (1), -- use local time universal (2) -- use universal or GMT } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to determine the format of the time/date stamp that is included with each audit trail message the system generates. This only applies if there is a Network Control Server for the IBM PC/AT (NCS/AT) or Remote Boot and Configuration Services (RBCS) server on the attached network. Audit trail messages are generated by various network events and are displayed on the NCS or RBCS console." ::= { a3ComAudit 1 } a3sysLogServerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "The address of the NCS or the RBCS that serves as the log server for the system. The log server receives all of the system's audit trail messages." ::= { a3ComAudit 2 } -- -- The Time group -- a3sysDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The current date and time as reflected by the system clock. The date is displayed via the User interface and Audit Trail Messages as yy/mm/dd hh:mm[:ss]. This same format must be used when setting the Date." ::= { a3ComTime 1 } a3sysDSTime OBJECT-TYPE SYNTAX INTEGER (-120..120) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the displacement, in minutes, from non-daylight savings time. The a3sysDSTime object, along with the a3sysTimeZone object, allows the system to support Universal time for network communications spanning different time zones." ::= { a3ComTime 2 } a3sysTimeZone OBJECT-TYPE SYNTAX INTEGER (-720..720) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of minutes displacement west of Greenwich the system's site is located. A negative number for this parameter indicates how many minutes displacement east of Greenwich the site is located. A positive number indicates the number of minutes west of Greenwich." ::= { a3ComTime 3 } -- -- The Access Control Group -- a3sysRemoteAccess OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines whether another device can access this system via REMOTE" ::= { a3ComAccCtl 1 } a3sysTelnetAccess OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines whether another device can access this system via TELNET" ::= { a3ComAccCtl 2 } a3sysConsoleAccess OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines whether another device can access this system via the Console" ::= { a3ComAccCtl 3 } a3sysSNMPAccess OBJECT-TYPE SYNTAX INTEGER { enabledTraps (1), enabledNoTraps (2), disabledTraps (3), disabledNoTraps (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines whether another device can access this system via SNMP. Note, once SNMP access is disabled, the NMS will no longer be able to access this system via SNMP. If this is set to enabledTraps(1), the system allows SNMP access and will send traps when appropriate. If this is set to enabledNoTraps(2), the system allows SNMP access, but no traps will be sent. If this is set to disabledTraps, the system does not allow SNMP access, but will send traps when appropriate. If this is set to disabledNoTraps(4), the system does not allow SNMP access and does not send any traps." ::= { a3ComAccCtl 4 } -- -- This table contains the SNMPv1 Community Strings -- a3sysSNMPCommTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysSNMPCommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains all the community strings known to the SNMP agent." ::= { a3ComAccCtl 5 } a3sysSNMPCommEntry OBJECT-TYPE SYNTAX A3sysSNMPCommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains information about a single community string. " INDEX { a3sysSNMPCommString } ::= { a3sysSNMPCommTable 1 } A3sysSNMPCommEntry ::= SEQUENCE { a3sysSNMPCommString DisplayString (SIZE(1..15)), a3sysSNMPCommAccess INTEGER, a3sysSNMPCommTrap INTEGER, a3sysSNMPCommStatus RowStatus } a3sysSNMPCommString OBJECT-TYPE SYNTAX DisplayString (SIZE(1..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a specific community string." ::= { a3sysSNMPCommEntry 1 } a3sysSNMPCommAccess OBJECT-TYPE SYNTAX INTEGER { readOnly (1), readWrite (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This identifies the level of access allowed for this community string." DEFVAL { readOnly } ::= { a3sysSNMPCommEntry 2 } a3sysSNMPCommTrap OBJECT-TYPE SYNTAX INTEGER { genericOnly (1), -- coldStart, warmStart, linkDown/Up authenOnly (2), -- authenticationFailure allTraps (3), noTraps (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies which traps get sent to the managers specified by this community string." DEFVAL { noTraps } ::= { a3sysSNMPCommEntry 3 } a3sysSNMPCommStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB." ::= { a3sysSNMPCommEntry 4 } -- -- This table contains the Managers that are allowed to use -- each of the community strings identified above. -- a3sysSNMPMgrTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysSNMPMgrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Managers that are allowed to use the community strings identified in a3sysSNMPCommTable. Each Manager is identified by its IP address." ::= { a3ComAccCtl 6 } a3sysSNMPMgrEntry OBJECT-TYPE SYNTAX A3sysSNMPMgrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry identifies a single Manager, community string pair." INDEX { a3sysSNMPMgrCommString, a3sysSNMPMgrAddress } ::= { a3sysSNMPMgrTable 1 } A3sysSNMPMgrEntry ::= SEQUENCE { a3sysSNMPMgrCommString DisplayString (SIZE(1..15)), a3sysSNMPMgrAddress IpAddress, a3sysSNMPMgrMask IpAddress, a3sysSNMPMgrStatus RowStatus } a3sysSNMPMgrCommString OBJECT-TYPE SYNTAX DisplayString (SIZE(1..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a specific community string." ::= { a3sysSNMPMgrEntry 1 } a3sysSNMPMgrAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a single Management station that is allowed to use the community string associated with this entry. The set of all entries with same value of a3sysSNMPMgrCommString identifies all the Managers that are allowed to use that community string." ::= { a3sysSNMPMgrEntry 2 } a3sysSNMPMgrMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object can be used to mask part of the IP address specified by a3sysSNMPMgrAddress. The use of this mask can then be used to identify a range of addresses that are allowed to use this community string." ::= { a3sysSNMPMgrEntry 3 } a3sysSNMPMgrStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB for specific instructions on how to do this." ::= { a3sysSNMPMgrEntry 4 } -- -- This table contains the IP addresses of -- stations that are allowed to access the NetBuilder -- via Telnet -- a3sysTelnetMgrTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysTelnetMgrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the IP addresses that are allowed to use Telnet to access to the NetBuilder in the TelnetManager table." ::= { a3ComAccCtl 7 } a3sysTelnetMgrEntry OBJECT-TYPE SYNTAX A3sysTelnetMgrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry identifies a single Manager, community string pair." INDEX { a3sysTelnetMgrAddress } ::= { a3sysTelnetMgrTable 1 } A3sysTelnetMgrEntry ::= SEQUENCE { a3sysTelnetMgrAddress IpAddress, a3sysTelnetMgrStatus RowStatus } a3sysTelnetMgrAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This identifies a single Management station that is allowed to use the Telnet to manage the NetBuilder. Maximally, six (6) IP addresses can be configured in each NB." ::= { a3sysTelnetMgrEntry 1 } a3sysTelnetMgrStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB for specific instructions on how to do this." ::= { a3sysTelnetMgrEntry 2 } a3sysPasswordTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysPasswordEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the system's passwords." ::= { a3ComAccCtl 8 } a3sysPasswordEntry OBJECT-TYPE SYNTAX A3sysPasswordEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry identifies a single system password." INDEX { a3sysUserName, a3sysOldPassword } ::= { a3sysPasswordTable 1 } A3sysPasswordEntry ::= SEQUENCE { a3sysPwStatus INTEGER, a3sysUserName DisplayString, a3sysUserLevel INTEGER, a3sysOldPassword DisplayString, a3sysNewPassword DisplayString } a3sysPwStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-write STATUS mandatory DESCRIPTION "User Status. `invalid' is used to indicate this user is no longer allowed to access this device, and the table entry may subsequently be re-used. Note that the Status of default Users cannot be set to invalid." ::= { a3sysPasswordEntry 1 } a3sysUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..10)) ACCESS read-only STATUS mandatory DESCRIPTION "An ASCII string for the User Name. Empty strings are not allowed. The index column for the User Table. There are two default users defined, 'root' and 'user'." ::= { a3sysPasswordEntry 2 } a3sysUserLevel OBJECT-TYPE SYNTAX INTEGER { monitor(1), secureMonitor(2), manager(3), specialist(4), security(5) } ACCESS read-write STATUS mandatory DESCRIPTION "User Access Level defining the scope of management allowed for this user. Note that the access level of default Users cannot be changed." ::= { a3sysPasswordEntry 3 } a3sysOldPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current password." ::= { a3sysPasswordEntry 4 } a3sysNewPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The new password." ::= { a3sysPasswordEntry 5 } a3sysSnmpPasswordCtl OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates whether this system's passwords can be changed via snmp." ::= { a3ComAccCtl 9 } -- -- The Misc System Group -- a3sysNetMapTime OBJECT-TYPE SYNTAX INTEGER (0..120) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds between broadcasts of the system's address on the attached network. This only applies to 3Com's NETMap protocol. If this object is set to 0, the broadcasting of the system's address is disabled." DEFVAL { 0 } ::= { a3ComSysMisc 1 } a3sysUIBinary OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } ACCESS read-write STATUS mandatory DESCRIPTION "If on, the system is allowed to negotiate for binary transmission when a Telnet connection is made." DEFVAL { off } ::= { a3ComSysMisc 2 } a3sysChangeTimestamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the value of sysUpTime when the most recent change was made to this system, either via the Console, TELNET, or through SNMP." ::= { a3ComSysMisc 3 } a3sysCpuUtil OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a measure of the current utilization of the CPU on this system." ::= { a3ComSysMisc 4 } a3sysCpuBrdMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The system's MAC address. For those devices whose CPU boards contain a MAC address, this object provides the value of that address (NB2's). For those devices whose CPU boards don't contain a MAC address (NB1's), this provides the MAC address of the first interface." ::= { a3ComSysMisc 5 } a3sysExpMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the MAC address to which the @m symbol is expanded when doing file copies." ::= { a3ComSysMisc 6 } a3sysVportTimestamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the value of sysUpTime when the last virtual port was added or deleted. This object should be used to determine if and when the set of virtual ports supported by this system has changed." ::= { a3ComSysMisc 7 } a3sysDefDrive OBJECT-TYPE SYNTAX INTEGER { driveA (1), driveB (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the current default drive for this system." ::= { a3ComSysMisc 8 } a3sysDefDriveType OBJECT-TYPE SYNTAX INTEGER { floppy (1), flash (2), unknown (3), noDrive (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the current default drive type for this system." ::= { a3ComSysMisc 9 } a3sysDriveStatus OBJECT-TYPE SYNTAX INTEGER { noDrives (1), driveA (2), driveB (3), driveAB (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies which disk drives are supported by this system. noDrives(1) means no disk drives are supported. driveA means only drive A is supported. driveB means only drive B is supported, while driveAB(4) means both drives A and B are supported." ::= { a3ComSysMisc 10 } a3sysBogusDhcpSvr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object has the IP address of the last seen bogus DHCP or BOOTP server." ::= { a3ComSysMisc 11 } a3sysNb2EepromVers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object returns the version number of the EEPROM on a NetBuilderII. Various features are dependent on having the correct version of EEPROM resident on the NetBuilderII." ::= { a3ComSysMisc 12 } a3sysX25Conns OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object returns the number of active X25 connections currently maintained by the NetBuilder." ::= { a3ComSysMisc 13 } -- -- -- this group controls Firmware related parameters -- a3sysFwSerBaudCons OBJECT-TYPE SYNTAX INTEGER { unknown (1), bps110 (2), bps300 (3), bps600 (4), bps1200 (5), bps2400 (6), bps4800 (7), bps9600 (8), bps19200 (9), bps38400 (10), bps57600 (11) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the baud rate for the console port, which is located on the CEC module's connector/LEDC panel." REFERENCE "NBII CEC Module Installation Guide: Serial Port Parameter." ::= { a3ComFW 1 } a3sysFwSerBaudAux OBJECT-TYPE SYNTAX INTEGER { unknown (1), bps110 (2), bps300 (3), bps600 (4), bps1200 (5), bps2400 (6), bps4800 (7), bps9600 (8), bps19200 (9) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the baud rate for the auxiliary port, which is located on the CEC module's connector/LEDC panel." REFERENCE "NBII CEC Module Installation Guide: Serial Port Parameter." ::= { a3ComFW 2 } a3sysFwSelfTest OBJECT-TYPE SYNTAX INTEGER { skip (1), testOnce (2), other (3), loop (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter determines how the system handles self tests when the system is powered on or reset. The system can be configured to skip its self tests, run self tests once, or run self tests continuously (loop)." REFERENCE "NBII CEC Module Installation Guide: Self Test Parameter." ::= { a3ComFW 3 } -- -- this group controls Booting related Firmware parameters -- a3sysReBoot OBJECT-TYPE SYNTAX INTEGER { other (1), stdReboot (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object can be used to reboot the system. If this object is set to stdReboot(2), the system's action is determined by the value of a3sysStartUpAction. If that object has the value monitor(1), the system will go into monitor mode. If that object has the value userListOnce(2) or userListForever(3), the system will attempt to reboot from the sources identified by the User Boot List. If this object is read, the value, other (1), will be returned." REFERENCE "NBII Ref. Guide, Commands: ReBoot." ::= { a3ComBoot 1 } a3sysTestBootTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Test Boot Time indicates the number of seconds after a test reboot the system will automatically reboot. Upon reboot, the system will start up a timer initialized to the value of this object. The object a3sysTestRecoveryTimer contains the real time value of this timer. The timer will automatically start counting down after the system comes up. If this timer expires, the system will automatically reboot using the Primary Boot Source. To cancel the timer, the object a3sysTestRecoveryTimer must be set to zero. This provides a recovery mechanism for a system under test that loses management connectivity." ::= { a3ComBoot 2 } a3sysStartUpAction OBJECT-TYPE SYNTAX INTEGER { monitor (1), userListOnce (2), userListForever (3), local (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter determines the boot source when the system is powered on or reset. If monitor (1) is chosen, the system enters monitor mode immediately. If userListOnce (2) is chosen, the system attempts to boot from primary and secondary sources defined by the User Boot List. (Specifics about the use of the secondary boot source are provided by a3sysBootSources.) This list may identify network boot sources or local floppy sources, or both. If userListForever (3) is chosen, the system will keep trying the sources listed in the User Boot List until one of them is successful. If local(4) is chosen, the system will boot from the local floppy. The name of the file used is identified by the value of a3sysUblFileName for the Primary Boot Source." REFERENCE "NBII CEC Module Installation Guide: Initial Boot Type Parameter." ::= { a3ComBoot 3 } a3sysTestRecoveryTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the real time value of the Test Recovery Timer. When the system is performing a 'test boot' (ie, a boot when a3sysBootSources equals testWithPrimaryBackup (3)), the system will start a countdown timer initialized to the value of a3sysBootTime. If this timer is allowed to count down to zero, the system will reboot, this time using the primary boot source instead of the test boot source. If the timer is disabled, however, before it counts down (the timer is disabled by setting the value of this object to zero), the system won't reboot and will continue to run the test boot source's software. This timer is part of a comprehensive software update strategy. See the relevant 3Com manuals for more details." ::= { a3ComBoot 4 } a3sysDirectedReBoots OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a counter that tracks the number of times the system has completed successfully a boot, no matter how the boot was initiated (power-on, front-panel-button reset, command line, or exception)." ::= { a3ComBoot 5 } a3sysExceptionReBoots OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This is a counter that tracks the number of times the system has crashed and a reboot sequence is begun by the exception handler. Note, some type of crashes are not able to update this counter due to various hardware lockups. Also note, this counter will be incremented when a user resets the system from the command line (RS). This will not be incremented, however, when the user reboots the system from the command line (RB)." ::= { a3ComBoot 6 } a3sysBootDump OBJECT-TYPE SYNTAX INTEGER { noDump (1), monitor (2), localDevice (3), userList (4), network (5) } ACCESS read-write STATUS mandatory DESCRIPTION "This determines whether or not a memory dump is performed if the system fails due to a software problem. If noDump (1) is selected, the system will not attempt to perform a memory dump. If monitor (2) is selected, the system goes directly into monitor mode and waits for further commands. If localDevice (3) is selected, the system dumps its memory to the local storage device. Since the memory dump will require several floppy disks, the system will prompt the user via the User Interface to change disks. If userList (4) is selected, the system will upload its memory to the source specified in the User Boot List. Only the NetBuilder Remote Office and NetBuilder II support the network(5) option. If this is set, the parameters in entry four (dump) of a3sysUserBootListTable identify the destination." REFERENCE "NBII CEC Module Installation Guide: Dump Destination Parameter." ::= { a3ComBoot 7 } a3sysBootSources OBJECT-TYPE SYNTAX INTEGER { primary (1), primaryAndSecondary (2), testWithPrimaryBackup (3), secondary (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is used to specify how the entries in this table are used. If this object is set to primary(1), the system will use only the primary boot source when rebooting. (note, this is the entry where a3sysUblSource = primary(1)). If this object is set to primaryAndSecondary(2), the system will attempt to boot first from the primary boot source, and, if that fails (after a3sysUblMaxRetries attemps), the system will try the secondary boot source. If this object has the value testWithPrimaryBackup(3), the system, when rebooting, will perform a test boot using the 'test' boot source. Note, the NetBuilder Remote Office and NetBuilder II use entry 3 in a3sysUserBootListTable as the 'test' boot source (a3sysUblSource = test(3)), while other 3Com routers (NetBuilder Remote, NetBuilder Remote Control, NetBuilder Local, and NetBuilder Remote Access) don't support all 4 rows in a3sysUserBootListTable, and simply use the secondary boot source (a3sysUblSource = secondary(2)) to identify the 'test' boot source. After booting from the 'test' boot source, if the Test Recovery Timer (a3sysTestRecoveryTimer) is allowed to count down to zero, the system will reboot using the primary boot source. (see the reference guide for details about test booting). When in this mode, to prevent the system from rebooting using the primary boot source, the Test Recovery Timer (a3sysTestRecoveryTimer) must be set to zero. Note, this object cannot be set to testWithPrimaryBackup(3) explicitly. Instead, by setting a3sysTestBootTimer to a non-zero value, the system will automatically go into 'Test Boot' mode and this object will be given the value testWithPrimaryBackup(3). If this object has the value secondary(4), the system will use only the secondary boot source when rebooting." ::= { a3ComBoot 8 } a3sysUserBootListTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysUserBootListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines a list of boot sources (and for the NetBuilder Remote Office -- memory dump destinations). There are two other parameters that dictate how the contents of this table are used. These parameters are represented by a3sysStartUpAction and a3sysBootSources. a3sysStartUpAction specifies what this system does when it first comes up. If a3sysStartUpAction is set to userListOnce (2), the system will make a single attempt to use the entries in this table to identify how it should boot. If a3sysStartUpAction is set to userListForever (3), the system will make repeated attempts at using the entries in this table. If a3sysStartUpAction indicates that the system is to use this table, the order in which the entries are used is dictated by a3sysBootSources. If a3sysBootSources has the value primary (1), the system will attempt to boot only from the source identified by entry 1 in this table. If a3sysBootSources has the value primaryAndSecondary(2), the system will attempt to boot first from the source identified by entry 1, and, if that source fails, the system will try the source identified by entry 2 (the secondary source). If a3sysBootSources has the value testWithPrimaryBackup(3), the system will perform a test boot using the test boot source. Note, for the NetBuilder Remote Office, this is the third entry (test) in this table. For the NetBuilder II and the NetBuilder I family( NetBuilder Local, NetBuilder Remote, NetBuilder RemoteAccess, and NetBuilder RemoteControl), the test boot source is identified by entry 2 (secondary) in this table. If the test boot source fails (see the Reference Guide for more details on test booting), the system will revert back to the source identified by entry 1 (primary) in this table. The NetBuilder Remote Office supports a fourth entry in this table, which identifies where over the network memory is to be dumped in the case of a system crash. Note, the destination device (a3sysUblDevice) must be set to network (3), in this case. Also note that many of the columns in this row will be irrelevant and won't affect where the memory gets dumped. Note, all entries in this table apply only to future boots. They don't necessarily provide information about previous boots." REFERENCE "NBII CEC Module Installation Guide: User Boot List Parameter." ::= { a3ComBoot 9 } a3sysUserBootListEntry OBJECT-TYPE SYNTAX A3sysUserBootListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table contains a single boot source." INDEX { a3sysUblSource } ::= { a3sysUserBootListTable 1 } A3sysUserBootListEntry ::= SEQUENCE { a3sysUblSource INTEGER, a3sysUblDevice INTEGER, a3sysUblFileName DisplayString, a3sysUblNetFile DisplayString, a3sysUblSlot INTEGER, a3sysUblInterface INTEGER, a3sysUblMaxRetries INTEGER, a3sysUblConfigFileDevice INTEGER, a3sysUblConfigFilePath DisplayString, a3sysUblConfigProt INTEGER, a3sysUblConfigUserName DisplayString (SIZE(0..20)), a3sysUblConfigPassword DisplayString (SIZE(0..20)), a3sysUblConfigAcct DisplayString (SIZE(0..30)), a3sysUblMacAddress INTEGER, a3sysUblCanonicalFlag INTEGER, a3sysUblRemoteProt INTEGER, a3sysUblBaudRate INTEGER, a3sysUblClockSource INTEGER, a3sysUblConnectorType INTEGER, a3sysUblWanAddress DisplayString (SIZE(0..80)), a3sysUblClientIpAddr IpAddress, a3sysUblServerIpAddr IpAddress, a3sysUblGwIpAddr IpAddress, a3sysUblConfigFileIpAddr IpAddress, a3sysUblIpMask IpAddress, a3sysUblAddressDiscovery INTEGER, a3sysUblPassword DisplayString } a3sysUblSource OBJECT-TYPE SYNTAX INTEGER { primary (1), secondary (2), test (3), dump (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the entry number in this table. Currently, the table is limited to two entries. The first entry is labelled primary(1), the next has the label secondary(2). The NetBuilder RemoteOffice and NetBuilder II (as of sw version 8.0) supports two additional entries. Entry three (test) identifies a separate boot block which is used when doing a test boot. Entry four (dump) identifies where memory is to be dumped. Note, only a subset of the columns in this entry are relevant. Specifically, a3sysUblDevice must have the value network(3) (ie, memory dumps are preformed only over the network by the NBRO)." REFERENCE "NBII CEC Module Installation Guide: User Boot List" ::= { a3sysUserBootListEntry 1 } a3sysUblDevice OBJECT-TYPE SYNTAX INTEGER { localMediaA (1), localMediaB (2), network (3), monitor (4), other (5), auto (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the source from which the system attempts to boot. If this object is set to localMediaA(1), the system will attempt to boot from drive A of the local storage media (A is the flash drive for those systems with both flash and floppy drives), using the filename identified by a3sysUblFileName. If this is set to localMediaB(2), the system will boot from drive B. If this object is set to network (3), the system will attempt to boot from a BOOTP/TFTP server attached to the network. The network interface that is used in the booting is identified by both a3sysUblSlot and a3sysUblInterface. The name of the boot file on the remote system is identified by a3sysUblFileName. monitor(4) is no longer supported. If this object has the value other(5), nothing has been specified." REFERENCE "NBII CEC Module Installation Guide: User Boot List: Boot Source Parameter." ::= { a3sysUserBootListEntry 2 } a3sysUblFileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the path and name of the boot file. For example, to specify the file boot.29k in the root directory, this object should have the value 'boot.29k'" REFERENCE "NBII CEC Module Installation Guide: User Boot List: Boot Filename Parameter." ::= { a3sysUserBootListEntry 3 } a3sysUblNetFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS deprecated DESCRIPTION "This object has been deprecated. (use a3sysUblFileName regardless of whether it's local or remote)." REFERENCE "NBII CEC Module Installation Guide: User Boot List: Network Boot String Parameter." ::= { a3sysUserBootListEntry 4 } a3sysUblSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the physical slot where the IO module from which the system will be booting is installed. This only applies when a3sysUblDevice is set to network(2)" REFERENCE "NBII CEC Module Installation Guide: User Boot List: Boot Source Parameter." ::= { a3sysUserBootListEntry 5 } a3sysUblInterface OBJECT-TYPE SYNTAX INTEGER { unknown(1), interfaceA (2), interfaceB (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the physical port on the IO module (installed in the slot identified by a3sysUblSlot) that the system will be booting from. This only applies when a3sysUblDevice is set to network(2). If there is only one connector in the module, this object should have the value: interfaceA(2)." REFERENCE "NBII CEC Module Installation Guide: User Boot List: Boot Source Parameter." DEFVAL { interfaceA } ::= { a3sysUserBootListEntry 6 } a3sysUblMaxRetries OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object determines the number of times the system will try to boot from the source identified by this table entry before going to the next entry." REFERENCE "NBII CEC Module Installation Guide: User Boot List: Maximum Retries Parameter." ::= { a3sysUserBootListEntry 7 } a3sysUblConfigFileDevice OBJECT-TYPE SYNTAX INTEGER { bootDevice (1), local (2), network (3), other (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the device used to access the configuration files needed by this system. If this object has the value bootDevice(1), the system will look for its configuration files on the same device as its boot files. This device is specified by a3sysUblDevice. If this object has the value network(3), the system will look for its configuration files on the device specified by a3sysUblConfigIpAddr. If this object has the value local(2), the system will look for its configuration files on the local storage media. If this object has the value other(4), nothing has been specified. In all the cases listed above, the path for the configuration files is specified by a3sysUblConfigFilePath." ::= { a3sysUserBootListEntry 8 } a3sysUblConfigFilePath OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the path to the configuration files needed by this system." ::= { a3sysUserBootListEntry 9 } a3sysUblConfigProt OBJECT-TYPE SYNTAX INTEGER { fap (1), ftp (2), other (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the protocol to use to get the configuration files if they are stored across the network. Note, this applies only if the value of a3sysUblConfigFileDevice is network(3) or bootDevice(1). If a3sysUblConfigFileDevice has the value bootDevice(1), then the corresponding instance of a3sysUblDevice must be network(2) for this object to have relevance. This object has been changed to read-only in 9.0. The only valid value for this object is ftp(2)." ::= { a3sysUserBootListEntry 10 } a3sysUblConfigUserName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the Username to be used by the file service protocol identified the corresponding instance of a3sysUblConfigProt." ::= { a3sysUserBootListEntry 11 } a3sysUblConfigPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the Password to be used by the file service protocol identified by the corresponding instance of a3sysUblConfigProt. Note, for reasons of security, the value of this object will be hidden. A string of 4 stars (*) will be returned in response to any GET or GETNEXT request." ::= { a3sysUserBootListEntry 12 } a3sysUblConfigAcct OBJECT-TYPE SYNTAX DisplayString (SIZE(0..30)) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the Account Name used by the file service protocol. Note, for reasons of security, the value of this object will be hidden. A string of 4 stars (*) will be returned in response to any GET or GETNEXT request." ::= { a3sysUserBootListEntry 13 } a3sysUblMacAddress OBJECT-TYPE SYNTAX INTEGER { cpu-module (1), io-module (2), other (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The MAC address to be used for booting over the network. This can be configured to use either the MAC address assigned to the CPU module or the MAC address assigned to the I/O module over which the boot is being performed." REFERENCE "NBII CEC Module Installation Guide: System IP Addresses: Boot MAC Address Parameter." ::= { a3sysUserBootListEntry 14 } a3sysUblCanonicalFlag OBJECT-TYPE SYNTAX INTEGER { other (1), canonical (2), nonCanonical (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This controls the format of addresses within ARP packets sent by this system." ::= { a3sysUserBootListEntry 15 } a3sysUblRemoteProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ppp (2), frameRelay (3), auto (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies which serial link protocol to use if a3sysUblSlot identifies a slot with a High Speed Serial board. If this is set to auto (4), the system will try all supported protocols until the serial line is active. If there is a different kind of board in that slot, the value of this object is ignored." ::= { a3sysUserBootListEntry 16 } a3sysUblBaudRate OBJECT-TYPE SYNTAX INTEGER { unknown (1), bps9600 (2), kbps19 (3), kbps38 (4), kbps56 (5), kbps64 (6), kbps128 (7), kbps256 (8), kbps448 (9), kbps1536 (10), kbps2048 (11), mbps4 (12), mbps16 (13) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the serial line or Token Ring baud rate. For all other types of ports, this object will be ignored." ::= { a3sysUserBootListEntry 17 } a3sysUblClockSource OBJECT-TYPE SYNTAX INTEGER { internal (1), external (2), unknown (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies whether to use an internal or external clock source. This applies only to High Speed Serial ports." ::= { a3sysUserBootListEntry 18 } a3sysUblConnectorType OBJECT-TYPE SYNTAX INTEGER { unknown (1), rs232 (2), v35 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the serial line connector type." ::= { a3sysUserBootListEntry 19 } a3sysUblWanAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies a string to initiate a WAN connection. The specified string required is interface and protocol specific. The maximum string length is 80 bytes. Note, this applies only to High Speed Serial ports." ::= { a3sysUserBootListEntry 20 } a3sysUblClientIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of this system used in packets when booting over the network." REFERENCE "NBII CEC Module Installation Guide: System IP Addresses: Client IP address Parameter." ::= { a3sysUserBootListEntry 21 } a3sysUblServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the Boot Server." REFERENCE "NBII CEC Module Installation Guide: System IP Addresses: Server IP Address Parameter." ::= { a3sysUserBootListEntry 22 } a3sysUblGwIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the gateway that will forward packets to the Boot Server." REFERENCE "NBII CEC Module Installation Guide: System IP Addresses: Gateway IP Address Parameter." ::= { a3sysUserBootListEntry 23 } a3sysUblConfigFileIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the configuration files Server, if needed." REFERENCE "NBII CEC Module Installation Guide: System IP Addresses: FAP Server IP Address Parameter." ::= { a3sysUserBootListEntry 24 } a3sysUblIpMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The mask to be applied to the addresses specified above." ::= { a3sysUserBootListEntry 25 } a3sysUblAddressDiscovery OBJECT-TYPE SYNTAX INTEGER { other (1), bootp (2), configAddr (3), bootpRarp (4), rarp (5), rarpBootp (6) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the address discovery protocol to use for booting from the network. If configAddr(3) is specified, then the configured addresses are used. If nothing has been specified, other(1) is returned." ::= { a3sysUserBootListEntry 26 } a3sysUblPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..5)) ACCESS read-write STATUS mandatory DESCRIPTION "This is needed when booting over a port that uses a protocol that requires a password, e.g, PPP." ::= { a3sysUserBootListEntry 27 } -- -- The next table controls the booting of the Intelligent IO -- Boards. As of 8.0, IIO boards must boot from either -- local storage or from the location where the config files -- are stored (which may be from local storage). -- a3sysIioBootTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysIioBootEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table specifies where each IIO card obtains its boot image." ::= { a3ComBoot 10 } a3sysIioBootEntry OBJECT-TYPE SYNTAX A3sysIioBootEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table corresponds to a specific slot in the NetBuilder chassis. If an IIO board is in that slot, that entry determines where that IIO board obtains its boot image." INDEX { a3sysIioBootSlot } ::= { a3sysIioBootTable 1 } A3sysIioBootEntry ::= SEQUENCE { a3sysIioBootSlot INTEGER, a3sysIioBootFileName DisplayString, a3sysIioBootState INTEGER, a3sysIioBootTime TimeTicks, a3sysIioBootImage OBJECT IDENTIFIER } a3sysIioBootSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the slot into which the IIO board corresponding to this entry is placed." ::= { a3sysIioBootEntry 1 } a3sysIioBootFileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the path and name of the IIO board's boot image. If the value of this object specifies a drive, the path is assumed to start from root. If the value of this object does not specify a drive number, this object specifies the path starting from the config file directory specified by a3sysUblConfigFilePath. In this case, the value of this object must not begin with a slash '/'." ::= { a3sysIioBootEntry 2 } a3sysIioBootState OBJECT-TYPE SYNTAX INTEGER { empty (1), -- card not available for use up (2), -- card is up and running booting (3), -- card is in the process of booting recovering (4), -- card is recovering from a failed boot dumping (5), -- while recovering, card is dumping image halted (6), -- card has halted after failed boot selfTestFail (7), -- self test failed error (8) -- card's in unrecoverable errored state } ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the current state of the IIO card installed in this slot. If there is no IIO card in the slot, this object will have the value empty(1). If the card is up and running, this object will have the value up(2). If the card is booting, this object will have the value booting(3). If the boot has failed, and the card is in the process of recovering from the failed boot, this object will have the value recovering(4). If in the process of recovering, the IIO dumps its image, this object will have the value dumping(5). Note that this is simply a sub-state within the more general recovering state. If after recovering, the IIO card goes into a halted state, this object will have the value halted(6). If the IIO card gets into an unrecoverable state, this object will have the value error(8)." ::= { a3sysIioBootEntry 3 } a3sysIioBootTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the IIO board last went into the UP state." ::= { a3sysIioBootEntry 4 } a3sysIioBootImage OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The OID assigned to this version of Iio Software." ::= { a3sysIioBootEntry 5 } -- -- The Last Boot Group. This group contains information about the -- most recent boot of the system -- a3sysLastBootSource OBJECT-TYPE SYNTAX INTEGER { primary (1), secondary (2), monitor (3), test (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the source from which the system last booted. The specifics of the boot source can be found from the corresponding User Boot List entry." REFERENCE "NBII CEC Module Installation Guide: User Boot List: Boot Source Parameter." ::= { a3ComLastBoot 1 } a3sysLastBootError OBJECT-TYPE SYNTAX INTEGER { none (1), -- there have been no known -- failures unknownLocalAddress (2), unknownServerAddress (3), noServerResponse (4), fileTransferFailed (5), imageNotFound (6), imageInvalid (7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the reason for the most recent boot failure." ::= { a3ComLastBoot 2 } a3sysLastBootDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The date and time as reflected by the system clock at the time the system last rebooted. The date has the format yy/mm/dd hh:mm[:ss]." ::= { a3ComLastBoot 3 } a3sysLbConfigFileIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the configuration file server used during the most recent boot. Note, even if the configuration files were obtained locally, an address may have been configured. This is the address used when performing all ftp PUT and GET operations." ::= { a3ComLastBoot 4 } a3sysLbGwIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the gateway that was used to forward packets to the boot server or configuration file server during the last boot." ::= { a3ComLastBoot 5 } a3sysLbIpMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP subnet mask configured during the last boot." ::= { a3ComLastBoot 6 } a3sysLbConfigDevice OBJECT-TYPE SYNTAX INTEGER { bootDevice (1), local (2), network (3), other (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The config file device used during the last boot." ::= { a3ComLastBoot 7 } a3sysLbConfigFilePath OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "The config file path used during the last boot." ::= { a3ComLastBoot 8 } a3sysLbConfigUserName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "If the config files were obtained from a file server during the last boot, this object contains the user name used during the ftp transfer of those files." ::= { a3ComLastBoot 9 } -- -- The File Management group -- a3sysFmOperation OBJECT-TYPE SYNTAX INTEGER { other (1), copy (2), do (3), delete (4), rename (5), directory (6), format (7), copySystem (8), checksum (9), abortCopy (10), makeDir (11), rmDir (12), getFileInfo (13), ftpGet (14), ftpPut (15), cleanFlash (16) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to initiate a file management operation. When set to copy(2), the system will get the file from the Source device (identified by a3sysFmSourceIpAddr and a3sysFmSourceFile) and copy it to the Target device (identified by a3sysFmTargetIpAddr and a3sysFmTargetFile). Note, both the Source and Target devices cannot be remote systems. At least one must be the local system. All information about the file and the server is taken from the values of the other objects in this group. To avoid unnecessary errors, the relevant objects in this group should be examined and their values validated before setting this object to copy(2). Currently, the do(3) enumeration is not supported. If this object is set to delete(4), the system will delete a single file on the local storage device. The file is identified by a3sysFmTargetFile. For software release 6.2, the rename(5) enumeration is not supported. This is supported, however, by release 7.0. If this object is directory(6), the system will list the file in the directory identified by a3sysFmTargetFile. The resulting list can be obtained by examining a3sysDfTable. For software release 6.2, enumerations 7 through 9 are not supported. Enumeration 7 and 9 are supported by release 7.0. If this object is set to abortCopy(10), the system will abort any file copy process in progress. If this object is set to makeDir(11), the system will create a directory off the root directory. The name of this directory is specified by a3sysFmTargetFile. If this object is set to rmDir(12), the system will remove the directory identified by a3sysFmTargetFile. If this object is set to getFileInfo(13), the system will retrieve information about the file identified by a3sysFmTargetFile and return that information via the a3ComFileInfo group. (ie, examine the contents of that group after this object is set to getFileInfo(13)). If this object is set to ftpGet(14), the system will retrieve the file identified by a3sysFmSourceFile. It will retrieve the file from the device from which the configuration files were originally obtained. That device can be identified by a3sysLbConfigFileIpAddr. Note, even if the config files were obtained locally, a valid IP address may have been configured. That is the device used for future ftp operations. If a path is not specified, the file will be taken from the configuration file directory. The config file directory cay be identified by a3sysLbConfigFilePath. If a relative path is specified, and the configuration files were originally obtained (ie, at last boot) from the network, the path is interpreted relative to the configuration file directory. If a relative path is specified and the configuration files were originally obtained locally, the path is interpreted relative to the login directory. Absolute paths are allowed. Once obtained, the file will be placed in the location identified by a3sysFmTargetFile. Note, this must be on one of the local storage devices. If this object is set to ftpPut(15), the system will place the file identified by a3sysFmSourceFile and place it on the device from which the config files were obtained originally. The path and filename of the placed file is identified by a3sysFmTargetFile. As with ftpGet(14), if a relative path is specified, and the configuration files were originally obtained from the network, the path is interpreted relative to the configuration file directory. If a relative path is specified and the configuration files were originally obtained locally, the path is interpreted relative to the login directory. Absolut paths are allowed. Note, the source file must be on one of the local storage devices. If this object is read, other(1) will be returned." ::= { a3ComFileMgmt 1 } a3sysFmSourceIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the IP address of the Source device from which files are obtained. If this is set to zero's, the local storage device is assumed." ::= { a3ComFileMgmt 2 } a3sysFmSourceFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the path and name of a source file. For example, if the action specified by a3sysFmOperation is copy(2) or rename(5), this identifies the path and name of the file to be copied or renamed. If there is no leading path string, the source file will be accessed from the root directory. For devices with multiple disk drives, the drive will be identified by appending a prefix to the path. For example, a:/path/name" ::= { a3ComFileMgmt 3 } a3sysFmTargetIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the IP address of the target device to which files are copied, renamed, etc." ::= { a3ComFileMgmt 4 } a3sysFmTargetFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the path and name of the target file on the target system. (The filename may contain the string '@M' which will be expanded to the system MAC address. Alternatively, the filename may contain the string '@m' which will be expanded to the last six characters of the system MAC address. This provides a mechanism for a remote system to generate system specific filenames automatically.) If there is no leading path string, the file will be accessed from the root directory. For devices with multiple disk drives, the drive will be identified by appending a prefix to the path. For example, a:/path/name. If the action specified by a3sysFmOperation is copy(2), this identifies where, on the target system (identified by a3sysFmTargetIpAddr) the file is to be placed and the name to give it. If the action specified by a3sysFmOperation is delete(4), this identifies the path and name of the local file which is to be deleted. If the action specified by a3sysFmOperation is directory(6), this identifies the full path of the directory that is to be listed." ::= { a3ComFileMgmt 5 } a3sysFmStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), inProgress (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This identifies the current status of the file management operation. This applies to the following operations: copy(2), and directory(6). If there is an operation in progress, this object will have the value inProgress(2). Otherwise inactive(1) will be returned." ::= { a3ComFileMgmt 6 } a3sysFmTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the value of sysUpTime when the most recent file management operation was initiated." ::= { a3ComFileMgmt 7 } a3sysFmError OBJECT-TYPE SYNTAX INTEGER { none (1), -- no operations since initialization successful (2), -- the most recent operation was -- successful inProgress (3), -- another operation was already in -- progress badSourceAddr (4), -- the Source IP Address is invalid badSourceFile (5), -- the Source file is invalid badTargetAddr (6), -- the Target IP Address is invalid badTargetFile (7), -- the Target file is invalid noResponse (8), -- no response from the server noFile (9), -- the file or dir. could not be found noSpace (10), -- no space on destination system noPermission (11), -- destination device is write protected writeError (12), -- error encountered when writing timeout (13), -- timeout during transfer badChecksum (14), -- invalid file checksum computed badOperation (15), -- invalid file operation aborted (16), -- operation aborted by user other (17), -- an error not listed here badDefaultDrv (18), -- the Default Drive is not Local badTargetPort (19) -- the Target Udp/Tcp port is unreachable } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the results of the most recent attempt at a file operation. If no file operations have been attempted since the system was initialized, this object will have the value none(1). If the last operation was successful, this object will have the value successful(2). If the last operation could not be initiated because there was another operation in progress, this object will have the value inProgress (3). If the source IP Address is invalid, this object will have the value badSourceAddr(4). If the source file name contains a syntax error, this object will have the value badSourceFile(5). If the target IP Address is invalid, this object will have the value badTargetAddr(6). If there was a syntax error in the identification of the target file (a3sysFmTargetFile), this object will have the value badTargetFile(7). If the remote server does not respond, this object will have the value noResponse(8). If either the source file or target file could not be found, this object will have the value noFile(9). If there is no space on the destination system this object will have the value noSpace(10). If the destination file location is write protected, this object will have the value noPermission(11). If there is an error encountered while writing the file to its destination, this object will have the value writeError(12). If the transfer took too much time and exceeded its limits, this object will have the value timeout(13). If the verify operation failed, this object will have the value badChecksum(14). If the operation requested is not supported by this platform or software version, this object will have the value badOperation(15). If the opereration was aborted by a user, this object will have the value aborted(16). If no drive is indicated in either the source or target files, and the default drive is not local (this will be the case when the system obtained its config files over the network the last time it booted), this object will have the value badDefaultDrv(18). This object will have the value other(17) if an error occured that is not listed here." ::= { a3ComFileMgmt 8 } -- -- Disk File List Group -- a3sysDfTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of sysUpTime when the list of files on the system disk was last updated. This list is updated by setting a3sysFmOperation to directory(6)." ::= { a3ComFileList 1 } a3sysDfPath OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the directory path under which the files listed in a3sysDfTable were obtained. Where necessary, this object also identifies the disk drive where the files are stored." ::= { a3ComFileList 2 } a3sysDfTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysDfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains a listing of all the files in a specific directory on one of the systems disks. The directory and disk are identified by a3sysDfPath. Each entry in this table contains information about a single file." ::= { a3ComFileList 3 } a3sysDfEntry OBJECT-TYPE SYNTAX A3sysDfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table describes a single disk file." INDEX { a3sysDfName } ::= { a3sysDfTable 1 } A3sysDfEntry ::= SEQUENCE { a3sysDfName DisplayString, a3sysDfDir INTEGER } a3sysDfName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This contains the name of a single file on the disk." ::= { a3sysDfEntry 1 } a3sysDfDir OBJECT-TYPE SYNTAX INTEGER { file (1), directory (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies whether the file identified by the corresponding instance of a3sysDfName is a regular file or a directory." ::= { a3sysDfEntry 2 } a3ComDfTotalSpace OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total size (in bytes) of the drive identified by a3sysDfPath" ::= { a3ComFileList 4 } a3ComDfAvailableSpace OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The available space (in bytes) of the drive identified by a3sysDfPath." ::= { a3ComFileList 5 } -- -- FM Cksum Group -- -- This group provides information related to the checksums associated with -- files kept by the system -- a3sysFmCksum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the results of a ccitt crc16 cyclic redundancy check performed on the file specified by a3sysTargetFile. The value of a3sysTargetFile at the time this crc was performed is provided by a3sysFmCksumFile." ::= { a3ComFmCksum 1 } a3sysFmCksumFile OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the file upon which the last ccitt crc16 cyclic redundancy check was performed. The results of this operation are specified by a3sysFmCksum." ::= { a3ComFmCksum 2 } a3sysFmCksumTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of sysUpTime when the last ccitt crc16 cyclic redundancy check was performed. The results of this operation are specified by a3sysFmCksum." ::= { a3ComFmCksum 3 } -- -- FM General Info Group -- -- This group provides general information related to a specific -- file kept by the system. In order to get infomation about -- a specific file, set a3sysFmTargetFile to the desired file, -- and set a3sysFmOperation to 13. After a3sysFmStatus returns -- to inactive, and assuming no errors have been encountered (check -- the value of a3sysFmError, the objects in this group will provide -- information about the desired file. -- a3sysFiName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the name of the file to which the rest of this group refers." ::= { a3ComFileInfo 1 } a3sysFiDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the date when the file (specified by a3sysFiName was last updated. The format of the date is yy/mm/dd hh:min:sec." ::= { a3ComFileInfo 2 } a3sysFiTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the value of sysUpTime when this group of objects was last updated. To update this group, set a3sysFmTargetFile to the desired file, and set a3sysFmOperation to getFileInfo(13)." ::= { a3ComFileInfo 3 } a3sysFmSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the size of the file (specified by a3sysFiName) in bytes." ::= { a3ComFileInfo 4 } -- -- This next section specifies the behavior of this system in the event -- of a crash. -- -- -- The first table in this group specifies how this system recovers -- if a specific IIO board or the CEC board crashes. -- a3sysIioRecoveryTable OBJECT-TYPE SYNTAX SEQUENCE OF A3sysIioRecoveryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table specifies the recovery procedure for each Intelligent IO board in the system. This also specifies the recovery procedure for the CEC card. Note, the eeprom version must be 5 or greater for this table to operate properly." ::= { a3ComRecovery 1 } a3sysIioRecoveryEntry OBJECT-TYPE SYNTAX A3sysIioRecoveryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table corresponds to a specific slot in the NetBuilder chassis. If an IIO board is in that slot, that entry determines the action taken by that IIO board in the event it crashes. There is also an entry in this table for the CEC board." INDEX { a3sysIioRecoverySlot } ::= { a3sysIioRecoveryTable 1 } A3sysIioRecoveryEntry ::= SEQUENCE { a3sysIioRecoverySlot INTEGER, a3sysIioRecoveryProcedure INTEGER, a3sysIioRecoverySelect INTEGER } a3sysIioRecoverySlot OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the slot into which the IIO (or CEC) board corresponding to this entry is placed." ::= { a3sysIioRecoveryEntry 1 } a3sysIioRecoveryProcedure OBJECT-TYPE SYNTAX INTEGER { halt (1), haltSystem (2), reboot (3), rebootSystem (4), dumpAndReboot (5), selectiveDumpAndReboot (6) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object determines the action taken if the IIO (or CEC) crashes. If the value of this object is selectiveDumpAndReboot (5), the value of a3sysIioRecoverySelect determines which IIO (or CEC) boards will dump and reboot in the event that this IIO board crashes." ::= { a3sysIioRecoveryEntry 2 } a3sysIioRecoverySelect OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the IIO or CEC boards that will dump and reboot in the event this IIO or CEC board crashes. This object is relevant only if the value of a3sysIioRecoveryProcedure is selectiveDumpAndReboot (6). The boards are specified by their slot. Each slot is represented by a single bit in the value of this object. If that bit is set (to 1), then that board will dump and reboot. Slot 0 is used to identify the CEC board, and corresponds to the least significant bit in this object. Slot 1 is used to identify the IIO board in that slot and corresponds to the next significant bit in this object. The identification of all other boards follows this convention." ::= { a3sysIioRecoveryEntry 3 } -- -- Trap Defines -- a3BogusDhcpSvr TRAP-TYPE ENTERPRISE a3Com VARIABLES { a3sysBogusDhcpSvr } DESCRIPTION "A a3BogusDhcpSvr trap signifies that an unauthorized DHCP or BOOTP server has been detected on the network." ::= 100 END