ALTIGA-GLOBAL-REG device MIB details by Altiga Networks Inc
ALTIGA-GLOBAL-REG file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ALTIGA-GLOBAL-REG.
Vendor: | Altiga Networks Inc |
---|---|
Mib: | ALTIGA-GLOBAL-REG [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- *------------------------------------------------------------------ -- * ALTIGA-GLOBAL-REG.my: Altiga Networks Central Registration MIB. -- * -- * Altiga Networks was acquired by Cisco Systems on March 29, 2000 -- * -- * Copyright (c) 2002 by Cisco Systems, Inc. -- * All rights reserved. -- * -- *------------------------------------------------------------------ ALTIGA-GLOBAL-REG DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, enterprises FROM SNMPv2-SMI; altigaGlobalRegModule MODULE-IDENTITY LAST-UPDATED "200207100000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cvpn3000@cisco.com" DESCRIPTION "The Altiga Networks central registration module. Acronyms The following acronyms are used in this document: ACE: Access Control Encryption BwMgmt: Bandwidth Management CTCP: Cisco Transmission Control Protocol DHCP: Dynamic Host Configuration Protocol DNS: Domain Name Service FTP: File Transfer Protocol FW: Firewall HTTP: HyperText Transfer Protocol ICMP: Internet Control Message Protocol IKE: Internet Key Exchange IP: Internet Protocol LBSSF: Load Balance Secure Session Failover L2TP: Layer-2 Tunneling Protocol MIB: Management Information Base NAT: Network Address Translation NTP: Network Time Protocol PPP: Point-to-Point Protocol PPTP: Point-to-Point Tunneling Protocol SEP: Scalable Encryption Processor SNMP: Simple Network Management Protocol SSH: Secure Shell Protocol SSL: Secure Sockets Layer UDP: User Datagram Protocol VPN: Virtual Private Network " REVISION "200207100000Z" DESCRIPTION "Updated with new header" ::= { alGlobalRegModule 1 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- MIB Objects -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Altiga's root altigaRoot OBJECT IDENTIFIER ::= { enterprises 3076 } --cisco OBJECT IDENTIFIER ::= { enterprises 9 } --ciscoMgmt OBJECT IDENTIFIER ::= { cisco 9 } --ciscoExperiment OBJECT IDENTIFIER ::= { cisco 10 } -- Altiga's registrations and modules altigaReg OBJECT IDENTIFIER ::= { altigaRoot 1 } altigaModules OBJECT IDENTIFIER ::= { altigaReg 1 } alGlobalRegModule OBJECT IDENTIFIER ::= { altigaModules 1 } alCapModule OBJECT IDENTIFIER ::= { altigaModules 2 } alMibModule OBJECT IDENTIFIER ::= { altigaModules 3 } alComplModule OBJECT IDENTIFIER ::= { altigaModules 4 } alVersionMibModule OBJECT IDENTIFIER ::= { altigaModules 6 } alAccessMibModule OBJECT IDENTIFIER ::= { altigaModules 7 } alEventMibModule OBJECT IDENTIFIER ::= { altigaModules 8 } alAuthMibModule OBJECT IDENTIFIER ::= { altigaModules 9 } alPptpMibModule OBJECT IDENTIFIER ::= { altigaModules 10 } alPppMibModule OBJECT IDENTIFIER ::= { altigaModules 11 } alHttpMibModule OBJECT IDENTIFIER ::= { altigaModules 12 } alIpMibModule OBJECT IDENTIFIER ::= { altigaModules 13 } alFilterMibModule OBJECT IDENTIFIER ::= { altigaModules 14 } alUserMibModule OBJECT IDENTIFIER ::= { altigaModules 15 } alTelnetMibModule OBJECT IDENTIFIER ::= { altigaModules 16 } alFtpMibModule OBJECT IDENTIFIER ::= { altigaModules 17 } alTftpMibModule OBJECT IDENTIFIER ::= { altigaModules 18 } alSnmpMibModule OBJECT IDENTIFIER ::= { altigaModules 19 } alIpSecMibModule OBJECT IDENTIFIER ::= { altigaModules 20 } alL2tpMibModule OBJECT IDENTIFIER ::= { altigaModules 21 } alSessionMibModule OBJECT IDENTIFIER ::= { altigaModules 22 } alDnsMibModule OBJECT IDENTIFIER ::= { altigaModules 23 } alAddressMibModule OBJECT IDENTIFIER ::= { altigaModules 24 } alDhcpMibModule OBJECT IDENTIFIER ::= { altigaModules 25 } alWatchdogMibModule OBJECT IDENTIFIER ::= { altigaModules 26 } alHardwareMibModule OBJECT IDENTIFIER ::= { altigaModules 27 } alNatMibModule OBJECT IDENTIFIER ::= { altigaModules 28 } alLan2LanMibModule OBJECT IDENTIFIER ::= { altigaModules 29 } alGeneralMibModule OBJECT IDENTIFIER ::= { altigaModules 30 } alSslMibModule OBJECT IDENTIFIER ::= { altigaModules 31 } alCertMibModule OBJECT IDENTIFIER ::= { altigaModules 32 } alNtpMibModule OBJECT IDENTIFIER ::= { altigaModules 33 } alNetworkListMibModule OBJECT IDENTIFIER ::= { altigaModules 34 } alSepMibModule OBJECT IDENTIFIER ::= { altigaModules 35 } alIkeMibModule OBJECT IDENTIFIER ::= { altigaModules 36 } alSyncMibModule OBJECT IDENTIFIER ::= { altigaModules 37 } alT1E1MibModule OBJECT IDENTIFIER ::= { altigaModules 38 } alMultiLinkMibModule OBJECT IDENTIFIER ::= { altigaModules 39 } alSshMibModule OBJECT IDENTIFIER ::= { altigaModules 40 } alLBSSFMibModule OBJECT IDENTIFIER ::= { altigaModules 41 } alDhcpServerMibModule OBJECT IDENTIFIER ::= { altigaModules 42 } alAutoUpdateMibModule OBJECT IDENTIFIER ::= { altigaModules 43 } alAdminAuthMibModule OBJECT IDENTIFIER ::= { altigaModules 44 } alPPPoEMibModule OBJECT IDENTIFIER ::= { altigaModules 45 } alXmlMibModule OBJECT IDENTIFIER ::= { altigaModules 46 } alCtcpMibModule OBJECT IDENTIFIER ::= { altigaModules 47 } alFwMibModule OBJECT IDENTIFIER ::= { altigaModules 48 } alGroupMatchMibModule OBJECT IDENTIFIER ::= { altigaModules 49 } alACEServerMibModule OBJECT IDENTIFIER ::= { altigaModules 50 } alNatTMibModule OBJECT IDENTIFIER ::= { altigaModules 51 } alBwMgmtMibModule OBJECT IDENTIFIER ::= { altigaModules 52 } alIpSecPreFragMibModule OBJECT IDENTIFIER ::= { altigaModules 53 } -- Altiga's company-wide objects and events altigaGeneric OBJECT IDENTIFIER ::= { altigaRoot 2 } -- See altiga.mi2 -- Altiga's product-specific objects and events altigaProducts OBJECT IDENTIFIER ::= { altigaRoot 3 } -- Altiga's Agent profiles altigaCaps OBJECT IDENTIFIER ::= { altigaRoot 4 } -- See altiga-cap.mi2 -- Altiga Requirement specifications altigaReqs OBJECT IDENTIFIER ::= { altigaRoot 5 } -- We will likely have nothing here -- Altiga Experiments altigaExpr OBJECT IDENTIFIER ::= { altigaRoot 6 } -- We will likely have nothing here -- Altiga Product Families altigaHw OBJECT IDENTIFIER ::= { altigaReg 2 } -- VPN Concentrator Product altigaVpnHw OBJECT IDENTIFIER ::= { altigaHw 1 } -- VPN Concentrator Components altigaVpnChassis OBJECT IDENTIFIER ::= { altigaVpnHw 1 } altigaVpnIntf OBJECT IDENTIFIER ::= { altigaVpnHw 2 } altigaVpnEncrypt OBJECT IDENTIFIER ::= { altigaVpnHw 3 } -- VPN Concentrator Chassis -- Cxx (C10/15/20/30/50/60/80) 30xx vpnConcentrator OBJECT IDENTIFIER ::= { altigaVpnChassis 1 } -- C5/3005 vpnRemote OBJECT IDENTIFIER ::= { altigaVpnChassis 2 } -- 3002 vpnClient OBJECT IDENTIFIER ::= { altigaVpnChassis 3 } -- VPN Concentrator Chassis Revisions --Concentrators (C10/15/20/30/50/60/80) 30xx vpnConcentratorRev1 OBJECT-IDENTITY STATUS current DESCRIPTION "The first revision of Altiga's VPN Concentrator hardware. 603e PPC processor. C10/15/20/30/50/60." ::= { vpnConcentrator 1 } vpnConcentratorRev2 OBJECT-IDENTITY STATUS current DESCRIPTION "The second revision of Altiga's VPN Concentrator hardware. 740 PPC processor. C10/15/20/30/50/60." ::= { vpnConcentrator 2 } --Remotes (a.k.a. Concentrators) 3005 vpnRemoteRev1 OBJECT-IDENTITY STATUS current DESCRIPTION "The first revision of Altiga's VPN Concentrator (Remote) hardware. 8240 PPC processor." ::= { vpnRemote 1 } --Clients (a.k.a. Hardware Client) 3002 vpnClientRev1 OBJECT-IDENTITY STATUS current DESCRIPTION "The first revision of Altiga's VPN Hardware Client hardware. 8260 PPC processor." ::= { vpnClient 1 } -- VPN Concentrator Interface Cards (VOX also) -- none -- VPN Concentrator Encryption Cards -- none END