ALTIGA-SYNC-STATS-MIB device MIB details by Altiga Networks Inc
ALTIGA-SYNC-STATS-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ALTIGA-SYNC-STATS-MIB.
Vendor: | Altiga Networks Inc |
---|---|
Mib: | ALTIGA-SYNC-STATS-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- *------------------------------------------------------------------ -- * ALTIGA-SYNC-STATS-MIB.my: Altiga Sync Statistics MIB. -- * -- * Altiga Networks was acquired by Cisco Systems on March 29, 2000 -- * -- * Copyright (c) 2002 by Cisco Systems, Inc. -- * All rights reserved. -- * -- *------------------------------------------------------------------ ALTIGA-SYNC-STATS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF alStatsSync, alSyncGroup FROM ALTIGA-MIB alSyncMibModule FROM ALTIGA-GLOBAL-REG InterfaceIndex FROM IF-MIB; altigaSyncStatsMibModule MODULE-IDENTITY LAST-UPDATED "200209051300Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cvpn3000@cisco.com" DESCRIPTION "The Altiga Sync Statistics MIB models counters and objects that are of management interest. Acronyms The following acronyms are used in this document: CRC: Cyclic Redundancy Check HDLC: High-level Data Link Control MIB: Management Information Base MTU: Maximum Transmission Unit " REVISION "200209051300Z" DESCRIPTION "Added module compliance." REVISION "200207100000Z" DESCRIPTION "Updated with new header" ::= { alSyncMibModule 2 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- MIB Objects -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ alStatsSyncGlobal OBJECT IDENTIFIER ::= { alStatsSync 1 } alSyncStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlSyncStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SYNC interface statistics MIB." ::= { alStatsSync 2 } alSyncStatsEntry OBJECT-TYPE SYNTAX AlSyncStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry the alSyncStatsTable." INDEX { alSyncStatsSlot, alSyncStatsConn, alSyncStatsChannel } ::= { alSyncStatsTable 1 } AlSyncStatsEntry ::= SEQUENCE { alSyncStatsRowStatus RowStatus, alSyncStatsSlot Integer32, alSyncStatsConn Integer32, alSyncStatsChannel Integer32, alSyncStatsIfIndex InterfaceIndex, alSyncStatsPortState INTEGER, alSyncStatsRxFrames Counter32, alSyncStatsRxOctets Counter32, alSyncStatsRxReplenFails Counter32, alSyncStatsRxClockErrors Counter32, alSyncStatsRxDpllErrors Counter32, alSyncStatsRxFrameTooLongErrors Counter32, alSyncStatsRxFrameOctetAlignErrors Counter32, alSyncStatsRxAbortErrors Counter32, alSyncStatsRxCrcErrors Counter32, alSyncStatsRxRcvrOverrunErrors Counter32, alSyncStatsTxFrames Counter32, alSyncStatsTxOctets Counter32, alSyncStatsTxRingFullDropsErrors Counter32, alSyncStatsTxClockErrors Counter32, alSyncStatsTxFrameTooLongErrors Counter32, alSyncStatsTxUnderrunErrors Counter32 } alSyncStatsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this row." ::= { alSyncStatsEntry 1 } alSyncStatsSlot OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical slot for this Sync port. Part of the index." ::= { alSyncStatsEntry 2 } alSyncStatsConn OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical connector for this Sync port. Part of the index." ::= { alSyncStatsEntry 3 } alSyncStatsChannel OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The virtual channel for this Sync port. Part of the index." ::= { alSyncStatsEntry 4 } alSyncStatsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The IfIndex of this SYNC slot/conn/channel. This is configured, but configuration is not available via SNMP." ::= { alSyncStatsEntry 5 } alSyncStatsPortState OBJECT-TYPE SYNTAX INTEGER { init(1), -- port is coming up running(2), -- port has finished initialization -- and is waiting to transition to -- data state up(3), -- ready to pass packets down(4) -- port is down, unable to pass -- packets } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the interface. The init(1) state indicates the port is in the state of trying to come up. It will transition to running(2) once initialization is complete. up(3) indicates the interface is capable of passing packets. down(4) indicates the interface is no longer capable of passing packets." ::= { alSyncStatsEntry 6 } alSyncStatsRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received on this HDLC interface." ::= { alSyncStatsEntry 7 } alSyncStatsRxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets received on this HDLC interface." ::= { alSyncStatsEntry 8 } alSyncStatsRxReplenFails OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times receive buffers could not be allocated on this HDLC interface." ::= { alSyncStatsEntry 9 } alSyncStatsRxClockErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of clock errors on this HDLC interface." ::= { alSyncStatsEntry 10 } alSyncStatsRxDpllErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DPLL errors received on this HDLC interface." ::= { alSyncStatsEntry 11 } alSyncStatsRxFrameTooLongErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received long frame errors received on this HDLC interface." ::= { alSyncStatsEntry 12 } alSyncStatsRxFrameOctetAlignErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received long frame errors received on this HDLC interface." ::= { alSyncStatsEntry 13 } alSyncStatsRxAbortErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received abort errors received on this HDLC interface." ::= { alSyncStatsEntry 14 } alSyncStatsRxCrcErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CRC errors received on this HDLC interface." ::= { alSyncStatsEntry 15 } alSyncStatsRxRcvrOverrunErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CRC errors received on this HDLC interface." ::= { alSyncStatsEntry 16 } alSyncStatsTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted frames on this HDLC interface." ::= { alSyncStatsEntry 17 } alSyncStatsTxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted frames on this HDLC interface." ::= { alSyncStatsEntry 18 } alSyncStatsTxRingFullDropsErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames dropped on this HDLC interface because the transmit ring was full." ::= { alSyncStatsEntry 19 } alSyncStatsTxClockErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmit clock errors on this HDLC interface." ::= { alSyncStatsEntry 20 } alSyncStatsTxFrameTooLongErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames dropped this HDLC interface because they were long than the interface's MTU." ::= { alSyncStatsEntry 21 } alSyncStatsTxUnderrunErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitter underruns on this HDLC interface." ::= { alSyncStatsEntry 22 } altigaSyncStatsMibConformance OBJECT IDENTIFIER ::= { altigaSyncStatsMibModule 1 } altigaSyncStatsMibCompliances OBJECT IDENTIFIER ::= { altigaSyncStatsMibConformance 1 } altigaSyncStatsMibCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for agents which implement the Altiga Sync Statistics MIB." MODULE MANDATORY-GROUPS { altigaSyncStatsGroup } ::= { altigaSyncStatsMibCompliances 1 } altigaSyncStatsGroup OBJECT-GROUP OBJECTS { alSyncStatsRowStatus, alSyncStatsSlot, alSyncStatsConn, alSyncStatsChannel, alSyncStatsIfIndex, alSyncStatsPortState, alSyncStatsRxFrames, alSyncStatsRxOctets, alSyncStatsRxReplenFails, alSyncStatsRxClockErrors, alSyncStatsRxDpllErrors, alSyncStatsRxFrameTooLongErrors, alSyncStatsRxFrameOctetAlignErrors, alSyncStatsRxAbortErrors, alSyncStatsRxCrcErrors, alSyncStatsRxRcvrOverrunErrors, alSyncStatsTxFrames, alSyncStatsTxOctets, alSyncStatsTxRingFullDropsErrors, alSyncStatsTxClockErrors, alSyncStatsTxFrameTooLongErrors, alSyncStatsTxUnderrunErrors } STATUS current DESCRIPTION "The objects for SYNC configuration." ::= { alSyncGroup 2 } END