ASANTE-HUB1012-MIB device MIB details by Asante Technology
ASANTE-HUB1012-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ASANTE-HUB1012-MIB.
Vendor: | Asante Technology |
---|---|
Mib: | ASANTE-HUB1012-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- Title: AsanteHub 1012 MIB -- Date: January 18, 1993 (Latest Revision) -- Version: 2.0 -- Information in this document is subject to change without notice -- and does not represent a commitment on the part of -- Asante Technologies, Inc. No part of this document, or any -- associated software, product design or design concept, -- may be copied, reproduced or stored, in whole or in part, in any -- form or by any means mechanical, electronic, optical, photocopying, -- recording or otherwise, including translation to another language -- or format, except for your own internal use, without the express -- written consent of Asante Technologies, Inc. -- The AsanteHub 1012 MIB is supplied "AS IS", and Asante Technologies, -- Inc. makes no warranty, either express of implied, as to the use, -- operation, condition, or performance of the AsanteHub 1012 MIB. -- Copyright 1992 by Asante Technologies, Inc. All rights reserved. ASANTE-HUB1012-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, private, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; asante OBJECT IDENTIFIER ::= { enterprises 298} DisplayString ::= OCTET STRING -- This data type is used to model textual information -- taken from the NVT ASCII character set. By -- convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) PhysAddress ::= OCTET STRING -- This data type is used to model media addresses. For -- many types of media, this will be in a binary -- representation. For example, an ethernet address -- would be represented as a string of 6 octets. -- Asante Enterprise Specific Objects -- products OBJECT IDENTIFIER ::= { asante 1 } productId OBJECT IDENTIFIER ::= { asante 2 } snmpAgent OBJECT IDENTIFIER ::= { products 1 } adaptCard OBJECT IDENTIFIER ::= { products 2 } concentrator OBJECT IDENTIFIER ::= { products 3 } agentSw OBJECT IDENTIFIER ::= { snmpAgent 1 } agentFw OBJECT IDENTIFIER ::= { snmpAgent 2 } agentHw OBJECT IDENTIFIER ::= { snmpAgent 3 } -- the agent network protocol stack capability map agentNetProtoStkCapMap OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "This octet string represents the current protocol stack configuration supported by the agent, encoded as a bit string. Each protocol stack is represented by a single bit. When the value of a bit = 1, it indicates that the protocol stack on the agent represented by that bit is supported; when zero, the protocol stack is not supported. The number of octets in the string is always integer multiple of the octet. The first protocol stack will encode in the least significant bit of the first octet. Current, only IP Stack(bit 0) and IPX Stack(bit 1) were defined, all other bits should be zero." ::= { snmpAgent 4 } agentNetProtocol OBJECT IDENTIFIER ::= { snmpAgent 5 } ipagentProtocol OBJECT IDENTIFIER ::= { agentNetProtocol 1 } -- ipagentTrapRcvrTable OBJECT IDENTIFIER ::= { agentNetProtocol 2 } concChassis OBJECT IDENTIFIER ::= { concentrator 1 } concConfiguration OBJECT IDENTIFIER ::= { concentrator 2 } concStatistics OBJECT IDENTIFIER ::= { concentrator 3 } concStateCtrl OBJECT IDENTIFIER ::= { concentrator 4 } concNodeMgt OBJECT IDENTIFIER ::= { concentrator 5 } concAlarmMgt OBJECT IDENTIFIER ::= { concentrator 6 } concBasicGrp OBJECT IDENTIFIER ::= { concChassis 1 } eSmartHubConfig OBJECT IDENTIFIER ::= { concConfiguration 1 } eStatistics OBJECT IDENTIFIER ::= { concStatistics 1 } eStateCtrl OBJECT IDENTIFIER ::= { concStateCtrl 1 } eGlobalStatistics OBJECT IDENTIFIER ::= { eStatistics 1 } -- eGrpStatisticsTable OBJECT IDENTIFIER ::= { eStatistics 3 } -- ePortStatisticsTable OBJECT IDENTIFIER ::= { eStatistics 4 } -- eTrafficMatrixTable OBJECT IDENTIFIER ::= { eStatistics 5 } -- eSpecific OBJECT IDENTIFIER ::= { eStatistics 6 } -- eSmartHubSpec OBJECT IDENTIFIER ::= { eSpecific 1 } -- eCollGraphBar OBJECT IDENTIFIER ::= { eSmartHubSpec 1 } -- eActGraphBar OBJECT IDENTIFIER ::= { eSmartHubSpec 2 } -- Object Identifier for Asante's Products -- adapterProductId OBJECT IDENTIFIER ::= { productId 1 } -- concProductId OBJECT IDENTIFIER ::= { productId 2 } -- hub1012 OBJECT IDENTIFIER ::= { concProductId 1 } -- the agent Sw group agentRunTimeImageMajorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The major software version number of the agent run time image." ::= { agentSw 1 } agentRunTimeImageMinorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minor software version number of the agent run time image." ::= { agentSw 2 } agentImageLoadMode OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown localBoot(2), -- Load image from local flash EEPROM netBoot(3) -- Load image remotely from network } ACCESS read-write STATUS mandatory DESCRIPTION "Tells hub whether the software image is to be loaded from the FLASH EPROM or from over the network." ::= { agentSw 3 } agentRemoteBootInfo OBJECT-TYPE SYNTAX INTEGER { other(1), -- use boot protocol eepromBootInfo(2) -- use EEPROM boot parameters } ACCESS read-only STATUS mandatory DESCRIPTION "The method for getting boot parameter information." ::= { agentSw 4 } agentRemoteBootProtocol OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown boot protocol bootp-tftp(2), -- use bootp-tftp protocol tftp-only(3) -- use tftp protocol } ACCESS read-write STATUS mandatory DESCRIPTION "The netboot protocol that used to load the agent software." ::= { agentSw 5 } agentRemoteBootFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "The boot file name that is sent to the boot file server by agent boot code during boot time." ::= { agentSw 6 } agentOutBandDialString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the initialization string used by the Network Management station to establish the out-of-band connection for modem only." ::= { agentSw 7 } agentOutBandBaudRate OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown baud rate b1200(2), -- 1200 baud rate b2400(3), -- 2400 baud rate b4800(4), -- 4800 baud rate b9600(5) -- 9600 baud rate } ACCESS read-write STATUS mandatory DESCRIPTION "The baud rate setting for the out-of-band port." ::= { agentSw 8 } agentReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown reset(2), -- system reset not-reset(3) -- normal operation } ACCESS read-write STATUS mandatory DESCRIPTION "The object to allow software to perform 'push_button' system reset." ::= { agentSw 9 } -- the agent Hw group agentHwReVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The hardware reversion number of the network management module." ::= { agentHw 1 } agentHwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The hardware model number of the network management module" ::= { agentHw 2 } -- the agent Fw group agentFwMajorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The major firmware version number of the agent prom code." ::= { agentFw 1 } agentFwMinorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minor firmware version number of the agent prom code." ::= { agentFw 2 } -- the ipagent protocol group ipagentIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ipagent's administrative IP address. The current operational IP address can be obtained from the ipAdEntAddr in the ipAddrTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM." ::= { ipagentProtocol 1 } ipagentIpNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ipagent's administrative IP subnet mask. The current operational IP subnet mask can be obtained from the ipAdEntMask in the ipAddrTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM." ::= { ipagentProtocol 2 } ipagentDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The ipagent's administrative default gateway IP address. The current operational IP default gateway IP address can be obtained from the ipRouteDest in the ipRouteTable. This parameter will take effect only after reset hub. This parameter will always be updated in the EEPROM." ::= { ipagentProtocol 3 } ipagentBootServerAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the boot server that was used for booting this ipagent. This parameter will always be updated in the EEPROM." ::= { ipagentProtocol 4 } ipagentUnAuthIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the last station that tried to access this ipagent with an invalid community string." ::= { ipagentProtocol 5 } ipagentUnAuthComm OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The community string of the last station that tried to access this ipagent with an invalid community string." ::= { ipagentProtocol 6 } -- the ipagent trap receive table group ipagentTrapRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF IpagentTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table consisting of the list of Network Management Stations that are to receive traps generated by this agent." ::= { agentNetProtocol 2 } ipagentTrapRcvrEntry OBJECT-TYPE SYNTAX IpagentTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Destination IP address and community string for a particular trap server. " INDEX { ipagentTrapRcvrIpAddr } ::= { ipagentTrapRcvrTable 1 } IpagentTrapRcvrEntry ::= SEQUENCE { ipagentTrapRcvrIpAddr IpAddress, ipagentTrapRcvrStatus INTEGER, ipagentTrapRcvrComm OCTET STRING } ipagentTrapRcvrIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address for trap server receiving trap. " ::= { ipagentTrapRcvrEntry 1 } ipagentTrapRcvrStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), invalid(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Validation of individual trap receiver. If value of this object is set to invalid(3), then that particular entry is deemed invalid, meaning that the address for that entry is no longer valid because the entry has been removed from the table." ::= { ipagentTrapRcvrEntry 2 } ipagentTrapRcvrComm OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string for traps sent to this trap receiver." ::= { ipagentTrapRcvrEntry 3 } -- the concChassis group concChassisType OBJECT-TYPE SYNTAX INTEGER { other(1), aH1012(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The concentrator's chassis type." ::= { concBasicGrp 1 } concChassisBkplType OBJECT-TYPE SYNTAX INTEGER { other(1), no-backplane(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The concentrator's chassis backplane type." ::= { concBasicGrp 2 } concChassisBkplRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The concentrator's chassis backplane revision number." ::= { concBasicGrp 3 } -- chassis power supply table group concChassisPsTable OBJECT-TYPE SYNTAX SEQUENCE OF ConcChassisPsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains concentrator's power supply information." ::= { concBasicGrp 4 } concChassisPsEntry OBJECT-TYPE SYNTAX ConcChassisPsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entry in the table containing the information about a single power supply." INDEX { concChassisPsIndex } ::= { concChassisPsTable 1 } ConcChassisPsEntry ::= SEQUENCE { concChassisPsIndex INTEGER, concChassisPsModuleType INTEGER, concChassisPsStatus INTEGER } concChassisPsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the power supply table for which this entry contains power supply type and status." ::= { concChassisPsEntry 1 } concChassisPsModuleType OBJECT-TYPE SYNTAX INTEGER { other(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the power supply module type." ::= { concChassisPsEntry 2 } concChassisPsStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown good(2), -- power supply in good cond. bad(3) -- power supply in failed cond. } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the power supply module status." ::= { concChassisPsEntry 3 } -- chassis fan concChassisFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown no-fan(2), -- no fan is found at this model good(3), -- fan in good cond. bad(4) -- fan in failed cond. } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the fan status." ::= { concBasicGrp 5 } -- chassis group capacity concChassisGroupCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of groups that can be contained within the concentrator. " ::= { concBasicGrp 6 } concChassisGroupMap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This octet string represents the current configuration of groups, encoded as a bit string, each group is represented by a single bit." ::= { concBasicGrp 7 } concChassisGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF ConcChassisGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the group/slot in this chassis." ::= { concBasicGrp 8 } concChassisGrpEntry OBJECT-TYPE SYNTAX ConcChassisGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information for each slot in this chassis." INDEX { concChassisGrpIndex } ::= { concChassisGrpTable 1 } ConcChassisGrpEntry ::= SEQUENCE { concChassisGrpIndex INTEGER, concChassisGrpNumberPort INTEGER, concChassisGrpType INTEGER, concChassisGrpDescr DisplayString, concChassisGrpHwRev INTEGER } concChassisGrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the chassis group table for which this entry contains group related information." ::= { concChassisGrpEntry 1 } concChassisGrpNumberPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of port is available for up/down link within this group." ::= { concChassisGrpEntry 2 } concChassisGrpType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value represents the function of this group." ::= { concChassisGrpEntry 3 } concChassisGrpDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of this group device." ::= { concChassisGrpEntry 4 } concChassisGrpHwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The hardware revision number of this particular group." ::= { concChassisGrpEntry 5 } -- ConcConfiguration Group eSmartHubId OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Hub MAC address (octet string) found from prom chip in hub." ::= { eSmartHubConfig 1 } eSmartHubAssignedId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Assigned hub ID for Out-of-Band." ::= { eSmartHubConfig 2 } eSmartHubTerSwitch OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown terminal(2), -- switch is on terminal mode pc-modem(3) -- switch is on pc/modem mode } ACCESS read-only STATUS mandatory DESCRIPTION "Status of position of PC/terminal switch located on rear panel of hub. Switches between serial and parallel communications for modem/PC or terminal connection to RS-232 Port. Up (off) for PC, down (on) for terminal. If position of switch is changed, there will be no change in this status until hub is reset." ::= { eSmartHubConfig 3 } -- Currently, this object does not allow user -- to set new value. eSmartHubHwLoadPatStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Which logic configuration pattern is loaded into the Programmable Logic Device PLD." ::= { eSmartHubConfig 4 } eSmartHubHwLoadPatCapacity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "What kind of function the PLD can perform." ::= { eSmartHubConfig 5 } eSmartHubNodeAgeTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How long to keep node entry in node summary table, measured in sec. The maximum is 11 hours." ::= { eSmartHubConfig 6 } eSmartHub3in1LnConStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- BNC is connected or no connection uTP(2), -- 10BASE-T port is connected aUI(3), -- AUI port is connected uTP-and-AUI(4) -- both 10-T and AUI ports are connected } ACCESS read-only STATUS mandatory DESCRIPTION "Status of 3In1 Uplink which is located on rear panel of hub. Describes the physical link type or types currently connected." ::= { eSmartHubConfig 7 } eSmartHub3in1StateCtrl OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown uTP(2), -- 10BASE-T port is selected bNC(3), -- BNC port is selected aUI(4), -- AUI port is selected auto(5) -- automatically switched } ACCESS read-write STATUS mandatory DESCRIPTION "Whether using Auto-sense or manually selected a particular media type for the uplink connection. If using Auto-sense it first tries AUI. If AUI is not present then 10T. If neither AUI nor 10T is present, then it defaults to BNC." ::= { eSmartHubConfig 8 } -- enet concStatictics Global group eGlobalHubReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter of good or readable frames for this hub. Frame is between 64 and 1518 bytes in length and has SFD and good FCS." ::= { eGlobalStatistics 1 } eGlobalHubMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter of number of multicast frames for this hub. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included." ::= { eGlobalStatistics 2 } eGlobalHubBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter of number of broadcast frames for his hub. All 1s in network destination address. Multicast packets are not included." ::= { eGlobalStatistics 3 } eGlobalHubFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of data frames longer than 1518 bytes, with a SFD and good FCS." ::= { eGlobalStatistics 4 } eGlobalHubRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of data frames with size less than 64 bytes, with no CRC or alignment errors. " ::= { eGlobalStatistics 5 } eGlobalHubAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of frames which are not integer multiples of 1 byte." ::= { eGlobalStatistics 6 } eGlobalHubFragmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error)." ::= { eGlobalStatistics 7 } eGlobalHubFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of frames that failed Cyclic Redundancy Check (CRC)." ::= { eGlobalStatistics 8 } eGlobalHubIFGErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of occurrences of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds." ::= { eGlobalStatistics 9 } eGlobalHubDataRateMismatch OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of errors where incoming data rate is not with in the tolerance level of 10MHZ + or - 0.01%." ::= { eGlobalStatistics 10 } eGlobalHubShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of data burst where data is less than 10 bytes in length, with no SFD." ::= { eGlobalStatistics 11 } eGlobalHubCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter of collision flags, for this hub." ::= { eGlobalStatistics 12 } eGlobalHubLateCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of collisions occurring after the 64 byte collision window." ::= { eGlobalStatistics 13 } eGlobalHubMJLPs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter of MAU jabber lockup protection where hub repeater chip goes into lockup state." ::= { eGlobalStatistics 14 } eGlobalHubAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of all ports including 3in1 port being partitioned from network in response to 31 or more continuous collisions." ::= { eGlobalStatistics 15 } eGlobalHubSFDMissing OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of a burst of data greater than or equal to 10 bytes in length with no SFD." ::= { eGlobalStatistics 16 } eGlobalHubBadFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Global counter, for this hub, of total errored frame including toolong, runts, misaligned, or bad FCS." ::= { eGlobalStatistics 17 } -- eGroupStatistics group eGrpStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF EnetGrpStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of statistical information for each group." ::= { eStatistics 3 } eGrpStatisticsEntry OBJECT-TYPE SYNTAX EnetGrpStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry for individual group in table." INDEX { eGrpStatIndex } ::= { eGrpStatisticsTable 1 } EnetGrpStatisticsEntry ::= SEQUENCE { eGrpStatIndex INTEGER, eGrpStatReadableFrames Counter, eGrpStatMcastFrames Counter, eGrpStatBcastFrames Counter, eGrpStatFrameTooLongs Counter, eGrpStatRunts Counter, eGrpStatAlignmentErrors Counter, eGrpStatFragmentErrors Counter, eGrpStatFCSErrors Counter, eGrpStatIFGErrors Counter, eGrpStatDataRateMismatch Counter, eGrpStatShortEvents Counter, eGrpStatCollisions Counter, eGrpStatLateCollisions Counter, eGrpStatMJLPs Counter, eGrpStatAutoPartitions Counter, eGrpStatSFDMissing Counter, eGrpStatBadFrames Counter } eGrpStatIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the group for which this entry contains group statistical information." ::= { eGrpStatisticsEntry 1 } eGrpStatReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of 'good' or readable frames. Frame is between 64 and 1518 bytes in length and has SFD and good FCS." ::= { eGrpStatisticsEntry 2 } eGrpStatMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included." ::= { eGrpStatisticsEntry 3 } eGrpStatBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of number of broadcast frames. All 1s in network destination address. Multicast packets are not included." ::= { eGrpStatisticsEntry 4 } eGrpStatFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter for data frames longer than 1518 bytes, with a SFD and good FCS. " ::= { eGrpStatisticsEntry 5 } eGrpStatRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter for data frames with size less than 64 bytes, with no CRC or alignment errors." ::= { eGrpStatisticsEntry 6 } eGrpStatAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of frames which are not integer multiples of 1 byte ." ::= { eGrpStatisticsEntry 7 } eGrpStatFragmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error)." ::= { eGrpStatisticsEntry 8 } eGrpStatFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter frames that failed Cyclic Redundancy Check (CRC)." ::= { eGrpStatisticsEntry 9 } eGrpStatIFGErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds." ::= { eGrpStatisticsEntry 10 } eGrpStatDataRateMismatch OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of errors where incoming data rate is not with in the tolerance level of 10 MHZ + or - 0.01%." ::= { eGrpStatisticsEntry 11 } eGrpStatShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of data burst where data is less than 10 bytes in length, with no SFD." ::= { eGrpStatisticsEntry 12 } eGrpStatCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of collision flags." ::= { eGrpStatisticsEntry 13 } eGrpStatLateCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of collisions occurring after the 64 byte collision window." ::= { eGrpStatisticsEntry 14 } eGrpStatMJLPs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of MAU jabber lockup protection where hub repeater chip goes into lockup state." ::= { eGrpStatisticsEntry 15 } eGrpStatAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of ports in group autopartitioned in response to 31 or more continuous collisions." ::= { eGrpStatisticsEntry 16 } eGrpStatSFDMissing OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of a burst of data greater than or equal to 10 bytes in length with no SFD." ::= { eGrpStatisticsEntry 17 } eGrpStatBadFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Group counter of total errored frames including toolong, runts, misaligned, or bad FCS." ::= { eGrpStatisticsEntry 18 } -- ePortStatistics group ePortStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF EnetPortStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table for port specific network statistics." ::= { eStatistics 4 } ePortStatisticsEntry OBJECT-TYPE SYNTAX EnetPortStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry for individual port in table." INDEX { ePortGrpIndex, ePortIndex } ::= { ePortStatisticsTable 1 } EnetPortStatisticsEntry ::= SEQUENCE { ePortGrpIndex INTEGER, ePortIndex INTEGER, ePortStatReadableFrames Counter, ePortStatMcastFrames Counter, ePortStatBcastFrames Counter, ePortStatFrameTooLongs Counter, ePortStatRunts Counter, ePortStatAlignmentErrors Counter, ePortStatFragmentErrors Counter, ePortStatFCSErrors Counter, ePortStatIFGErrors Counter, ePortStatDataRateMismatch Counter, ePortStatShortEvents Counter, ePortStatCollisions Counter, ePortStatLateCollisions Counter, ePortStatMJLPs Counter, ePortStatAutoPartitions Counter, ePortStatSFDMissing Counter, ePortStatBadFrames Counter } ePortGrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the group for which this entry contains port statistical information." ::= { ePortStatisticsEntry 1 } ePortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the port for which this entry contains port statistical information." ::= { ePortStatisticsEntry 2 } ePortStatReadableFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of good or readable frames. Frame is between 64 and 1518 bytes in length and has SFD and good FCS." ::= { ePortStatisticsEntry 3 } ePortStatMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included." ::= { ePortStatisticsEntry 4 } ePortStatBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of number of broadcast frames. All 1s in network destination address. Multicast packets are not included." ::= { ePortStatisticsEntry 5 } ePortStatFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter for data frames longer than 1518 bytes, with a SFD and good FCS." ::= { ePortStatisticsEntry 6 } ePortStatRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter for data frames with size less than 64 bytes, with no CRC or alignment errors." ::= { ePortStatisticsEntry 7 } ePortStatAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of frames which are not integer multiples of 1 byte." ::= { ePortStatisticsEntry 8 } ePortStatFragmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error)." ::= { ePortStatisticsEntry 9 } ePortStatFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of frames that failed Cyclic Redundancy Check (CRC)." ::= { ePortStatisticsEntry 10 } ePortStatIFGErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of Interframe Gap Errors where time period between data frames is less than 5.5 micro seconds." ::= { ePortStatisticsEntry 11 } ePortStatDataRateMismatch OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of errors where incoming data rate is not with in the tolerance level of 10 MHZ + or - 0.01%." ::= { ePortStatisticsEntry 12 } ePortStatShortEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of data burst where data is less than 10 bytes in length, with no SFD." ::= { ePortStatisticsEntry 13 } ePortStatCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of collision flags." ::= { ePortStatisticsEntry 14 } ePortStatLateCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of collisions occurring after the 64 byte collision window." ::= { ePortStatisticsEntry 15 } ePortStatMJLPs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of MAU jabber lockup protection where hub repeater chip goes into lockup state." ::= { ePortStatisticsEntry 16 } ePortStatAutoPartitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of number of times port was autopartitioned in response to 31 or more continuous collisions." ::= { ePortStatisticsEntry 17 } ePortStatSFDMissing OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of a burst of data greater than or equal to 10 bytes in length with no SFD." ::= { ePortStatisticsEntry 18 } ePortStatBadFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Port counter of total errored frames including toolong, runts, misaligned, or bad FCS." ::= { ePortStatisticsEntry 19 } -- Ethernet traffic matrix group eTrafficMatrixTable OBJECT-TYPE SYNTAX SEQUENCE OF EnetTrafficMatrixEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table to analyze the number of packets received through network traffic by the size of each packet." ::= { eStatistics 5 } eTrafficMatrixEntry OBJECT-TYPE SYNTAX EnetTrafficMatrixEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Individual entry in matrix of packet lengths table." INDEX { eTrafficMatrixLength } ::= { eTrafficMatrixTable 1 } EnetTrafficMatrixEntry ::= SEQUENCE { eTrafficMatrixLength INTEGER, eTrafficMatrixRange INTEGER, eTrafficMatrixFramesCount Counter } eTrafficMatrixLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Starting length for each range in table." ::= { eTrafficMatrixEntry 1 } eTrafficMatrixRange OBJECT-TYPE SYNTAX INTEGER { other(1), -- Unknown from-1-to-63-bytes(2), -- 1-63 bytes range from-64-to-127-bytes(3), -- 64-127 bytes range from-128-to-255-bytes(4), -- 128-255 bytes range from-256-to-511-bytes(5), -- 256-511 bytes range from-512-to-767-bytes(6), -- 512-767 bytes range from-768-to-1023-bytes(7), -- 768-1023 bytes range from-1024-to-1518-bytes(8), -- 1024-1518 bytes range from-512-to-1023-bytes(9), -- 512-1023 bytes range from-65-to-511-bytes(10), -- 65-511 bytes range exact-64-bytes(11), -- exact 64 bytes over-1518-bytes(12) -- over 1518 bytes } ACCESS read-only STATUS mandatory DESCRIPTION "Range of packet sizes to be scanned for in network traffic." ::= { eTrafficMatrixEntry 2 } eTrafficMatrixFramesCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Counter for number of frames received for particular range specified by the MatrixRange. " ::= { eTrafficMatrixEntry 3 } -- eSmartSpecific Group eSpecific OBJECT IDENTIFIER ::= { eStatistics 6 } eSmartHubSpec OBJECT IDENTIFIER ::= { eSpecific 1 } -- eColGraphBar OBJECT IDENTIFIER ::= { eSmartHubSpec 1 } -- eUtilGraphBar OBJECT IDENTIFIER ::= { eSmartHubSpec 2 } eColGraphBar OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Information on hardware LED collision graph bar." ::= { eSmartHubSpec 1 } eUtilGraphBar OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Information on hardware LED for utilization graph bar." ::= { eSmartHubSpec 2 } -- ePort packet rate table ePortRateTable OBJECT-TYPE SYNTAX SEQUENCE OF EnetPortRateEntry ACCESS not-accessible STATUS optional DESCRIPTION "Network statistics for individual ports measured in Rate/Second." ::= { eSmartHubSpec 6 } ePortRateEntry OBJECT-TYPE SYNTAX EnetPortRateEntry ACCESS not-accessible STATUS optional DESCRIPTION "Individual entry in port rate table." INDEX { ePortRateGrpIndex, ePortRatePortIndex } ::= { ePortRateTable 1 } EnetPortRateEntry ::= SEQUENCE { ePortRateGrpIndex INTEGER, ePortRatePortIndex INTEGER, ePortRateReadableFrames INTEGER, ePortRateMcastFrames INTEGER, ePortRateBcastFrames INTEGER, ePortRateFrameTooLongs INTEGER, ePortRateRunts INTEGER, ePortRateAlignmentErrors INTEGER, ePortRateFragmentErrors INTEGER, ePortRateFCSErrors INTEGER, ePortRateIFGErrors INTEGER, ePortRateDataRateMismatch INTEGER, ePortRateShortEvents INTEGER, ePortRateCollisions INTEGER, ePortRateLateCollisions INTEGER, ePortRateMJLPs INTEGER, ePortRateAutoPartitions INTEGER, ePortRateSFDMissing INTEGER, ePortRateBadFrames INTEGER } ePortRateGrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The value of this object identifies the group for which this entry contains port statistical information." ::= { ePortRateEntry 1 } ePortRatePortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This value identifies the port for which this entry contains port statistical information." ::= { ePortRateEntry 2 } ePortRateReadableFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of good or readable frames." ::= { ePortRateEntry 3 } ePortRateMcastFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of number of muliticast frames. 1st bit in highest ordered bytes of destination address is set to 1. Broadcast packets are not included." ::= { ePortRateEntry 4 } ePortRateBcastFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of number of broadcast frames. All 1s in network destination address. Multicast packets are not included." ::= { ePortRateEntry 5 } ePortRateFrameTooLongs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of data frames longer than 1518 bytes, with a SFD and good FCS." ::= { ePortRateEntry 6 } ePortRateRunts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of data frames with size less than 64 bytes, with no CRC or alignment errors." ::= { ePortRateEntry 7 } ePortRateAlignmentErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of frames which are not integer multiples of 1 byte." ::= { ePortRateEntry 8 } ePortRateFragmentErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of frames greater than 2 bytes and less than 64 bytes, with SFD and bad FCS (CRC error)." ::= { ePortRateEntry 9 } ePortRateFCSErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of frames that failed Cyclic Redundancy Check (CRC)." ::= { ePortRateEntry 10 } ePortRateIFGErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of interframe Gap Errors where time period between data frames is less than 5.5 micro seconds." ::= { ePortRateEntry 11 } ePortRateDataRateMismatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of errors where incoming data rate is not with in the tolerance level of 10 MHz + or - 0.01%." ::= { ePortRateEntry 12 } ePortRateShortEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of data burst where data is less than 10 bytes in length, with no SFD." ::= { ePortRateEntry 13 } ePortRateCollisions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of collision flags." ::= { ePortRateEntry 14 } ePortRateLateCollisions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of collisions occurring after the 64 byte collision window." ::= { ePortRateEntry 15 } ePortRateMJLPs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of MAU jabber lockup protection where hub repeater chip goes into lockup state." ::= { ePortRateEntry 16 } ePortRateAutoPartitions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of times port was autopartitioned in response to 31 or more continuous collisions." ::= { ePortRateEntry 17 } ePortRateSFDMissing OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of a burst of data greater than or equal to 10 bytes in length with no SFD." ::= { ePortRateEntry 18 } ePortRateBadFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Rate of occurrence of total errored frames including toolong, runts, misaligned, or bad FCS." ::= { ePortRateEntry 19 } -- eStateCtrl Group ePortStateCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF EPortStateCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table for port control parameters." ::= { eStateCtrl 1 } ePortStateCtrlEntry OBJECT-TYPE SYNTAX EPortStateCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Individual entry of port control in table." INDEX { ePortStateGrpIndex, ePortStatePortIndex } ::= { ePortStateCtrlTable 1 } EPortStateCtrlEntry ::= SEQUENCE { ePortStateGrpIndex INTEGER, ePortStatePortIndex INTEGER, ePortStateType INTEGER, ePortStateLinkStatus INTEGER, ePortStateLinkIntegTest INTEGER, ePortStateAutoPartStatus INTEGER, ePortStateJabberStatus INTEGER, ePortStateJabberState INTEGER, ePortStateAdminState INTEGER, ePortStateRDTState INTEGER, ePortStatePolarityStatus INTEGER, ePortStatePolarityState INTEGER } ePortStateGrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the group for which this entry contains port control information." ::= { ePortStateCtrlEntry 1 } ePortStatePortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value identifies the port for which this entry contains port control information." ::= { ePortStateCtrlEntry 2 } ePortStateType OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown bNC(2), -- BNC port aUI(3), -- aui port rJ45(4), -- 10 baset port foil(5), -- fiber optics three-in-one(6) -- three in one port } ACCESS read-only STATUS mandatory DESCRIPTION "Type of cabling physically connected to port." ::= { ePortStateCtrlEntry 3 } ePortStateLinkStatus OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown linkon(2), -- link on linkoff(3) -- link off } ACCESS read-only STATUS mandatory DESCRIPTION "Link status for particular port. On=physical link if link test enabled. Off=no physical link exists or link test is disabled." ::= { ePortStateCtrlEntry 4 } ePortStateLinkIntegTest OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown linkTestEnable(2), -- link int test enable linkTestDisable(3) -- link int test disable } ACCESS read-write STATUS mandatory DESCRIPTION "Set can enable or disabled link integrity test. Get will say if link integrity test is enabled (2) or disabled (3)." ::= { ePortStateCtrlEntry 5 } ePortStateAutoPartStatus OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown autopartitioned(2), notautopartitioned(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Whether port has been autopartitioned (2) or not autopartitioned (3)." ::= { ePortStateCtrlEntry 6 } ePortStateJabberStatus OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown on(2), -- port jabbering off(3) -- port not jabbering } ACCESS read-only STATUS mandatory DESCRIPTION "Jabber detection for port. If On(2), then jabber occurred on this port. Off(3), then no jabber occurred or jabber detection has been manually disabled." ::= { ePortStateCtrlEntry 7 } ePortStateJabberState OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown enabled(2), -- enabled disabled(3) -- disabled } ACCESS read-write STATUS mandatory DESCRIPTION "Set can enable or disable jabber detection test. Get will say if jabber detection test is enabled (2) or disabled (3)." ::= { ePortStateCtrlEntry 8 } ePortStateAdminState OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown enabled(2), -- enabled disabled(3) -- disabled } ACCESS read-write STATUS mandatory DESCRIPTION "Set will manually enable or disable any port. Get will say if port has been enabled (2) or disabled (3)." ::= { ePortStateCtrlEntry 9 } ePortStateRDTState OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown unreduce(2), -- normal operation reduce(3) -- reduced threshold } ACCESS read-write STATUS mandatory DESCRIPTION "Whether RecvThreshold has been enabled or disabled. Can use this to lower noise threshold (tolerance) so that longer twisted pair links can be used." ::= { ePortStateCtrlEntry 10 } ePortStatePolarityStatus OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown normal(2), reversed(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Polarity is correct (2) or not for this port." ::= { ePortStateCtrlEntry 11 } ePortStatePolarityState OBJECT-TYPE SYNTAX INTEGER { others(1), -- unknown enabled(2), -- enabled disabled(3) -- disabled } ACCESS read-write STATUS mandatory DESCRIPTION "Autopolarity correction enabled or disabled. Allows hub to make electrical corrections automatically if cable does not reverse polarity within wire pairs. If do not want this correction to take place, autocorrection can be disabled." ::= { ePortStateCtrlEntry 12 } -- Node Summary Group ( Node Traffic Matrix Table ) nodeSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF NodeSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Node summary of all traffic through hub." ::= { concNodeMgt 1 } nodeSummaryEntry OBJECT-TYPE SYNTAX NodeSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Individual entry in node summary table. " INDEX { nodeSummaryGrpIndex, nodeSummaryPortIndex, nodeSummarySrcMacAddr, nodeSummaryDestMacAddr } ::= { nodeSummaryTable 1 } NodeSummaryEntry ::= SEQUENCE { nodeSummaryGrpIndex INTEGER, nodeSummaryPortIndex INTEGER, nodeSummarySrcMacAddr PhysAddress, nodeSummaryDestMacAddr PhysAddress, nodeSummaryEtherType INTEGER, nodeSummaryIpAddrPair OCTET STRING } nodeSummaryGrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Group Id for identifying the group where node activity is detected." ::= { nodeSummaryEntry 1 } nodeSummaryPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port Id for identifying the port where node activity is detected." ::= { nodeSummaryEntry 2 } nodeSummarySrcMacAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The source MAC address of the node that is transmitting frames received by this port." ::= { nodeSummaryEntry 3 } nodeSummaryDestMacAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The destination MAC address of the node to which frames are being received by this port. " ::= { nodeSummaryEntry 4 } nodeSummaryEtherType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The 2 bytes after the source (src) address in packet." ::= { nodeSummaryEntry 5 } nodeSummaryIpAddrPair OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Destination and source IP address if packet is an Ethernet IP packet. It the packet is not an Ethernet IP packet, then the information may not be accurate." ::= { nodeSummaryEntry 6 } -- Node Security Table Level One nodeSecurity OBJECT IDENTIFIER ::= { concNodeMgt 2 } nodeSecuLev1Table OBJECT-TYPE SYNTAX SEQUENCE OF NodeSecuLev1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of nodes which have access to particular ports. Nodes are identified by MAC address." ::= { nodeSecurity 1 } nodeSecuLev1Entry OBJECT-TYPE SYNTAX NodeSecuLev1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Individual entry for node security table." INDEX { nodeSecuLev1GrpIndex, nodeSecuLev1PortIndex } ::= { nodeSecuLev1Table 1 } NodeSecuLev1Entry ::= SEQUENCE { nodeSecuLev1GrpIndex INTEGER, nodeSecuLev1PortIndex INTEGER, nodeSecuLev1Status INTEGER, nodeSecuLev1AllowedAddr PhysAddress, nodeSecuLev1Action INTEGER } nodeSecuLev1GrpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Group ID for port which verifying node access." ::= { nodeSecuLev1Entry 1 } nodeSecuLev1PortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specific port for which verifying node access." ::= { nodeSecuLev1Entry 2 } nodeSecuLev1Status OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), invalid(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Address is valid or invalid." ::= { nodeSecuLev1Entry 3 } nodeSecuLev1AllowedAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "MAC address of nodes allowed for particular port." ::= { nodeSecuLev1Entry 4 } nodeSecuLev1Action OBJECT-TYPE SYNTAX INTEGER { other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Set action for node intrusion violation." ::= { nodeSecuLev1Entry 5 } -- Concentrator Alarm thresholdAlarm OBJECT IDENTIFIER ::= { concAlarmMgt 1 } -- (Basic) Threshold table thresholdLev1Table OBJECT-TYPE SYNTAX SEQUENCE OF ThresholdLev1Entry ACCESS not-accessible STATUS optional DESCRIPTION "Threshold/trap table." ::= { thresholdAlarm 1 } thresholdLev1Entry OBJECT-TYPE SYNTAX ThresholdLev1Entry ACCESS not-accessible STATUS optional DESCRIPTION "Individual entry in threshold trap table." INDEX { thresholdLev1Index } ::= { thresholdLev1Table 1 } ThresholdLev1Entry ::= SEQUENCE { thresholdLev1Index INTEGER, thresholdLev1Status INTEGER, thresholdLev1Target INTEGER, thresholdLev1GroupIndex INTEGER, thresholdLev1PortIndex INTEGER, thresholdLev1Subject INTEGER, thresholdLev1SampleType INTEGER, thresholdLev1StartupAlarm INTEGER, thresholdLev1WaterMark INTEGER, thresholdLev1DetectedValue INTEGER, thresholdLev1RisingEvent INTEGER, thresholdLev1FallingEvent INTEGER, thresholdLev1Interval INTEGER, thresholdLev1OwnerString OCTET STRING } thresholdLev1Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "An index that uniquely identifies an entry in the alarm table." ::= { thresholdLev1Entry 1 } thresholdLev1Status OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), invalid(3) } ACCESS read-write STATUS optional DESCRIPTION "Status of entry in threshold/trap table." ::= { thresholdLev1Entry 2 } thresholdLev1Target OBJECT-TYPE SYNTAX INTEGER { other(1), hub(2), port(3) } ACCESS read-write STATUS optional DESCRIPTION "Set target for threshold definition. Either whole hub(2) or particular port (3)." ::= { thresholdLev1Entry 3 } thresholdLev1GroupIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Group ID for trap set. One note--if the target is selected as hub, the group index will be ignored." ::= { thresholdLev1Entry 4 } thresholdLev1PortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Port number for trap set. One note--if the target is selected as hub, the port index will be ignored." ::= { thresholdLev1Entry 5 } thresholdLev1Subject OBJECT-TYPE SYNTAX INTEGER { other(1), readable-frames(2), mcast-frames(3), bcast-frames(4), frame-too-longs(5), runts(6), alignment-errors(7), fragment-errors(8), fCS-errors(9), iFG-errors(10), data-rate-mismatch(11), short-events(12), collisions(13), late-collisions(14), auto-partitions(15), sfd-missing(16), bad-frames(17) } ACCESS read-write STATUS optional DESCRIPTION "Variable checking for in trap. These are the type of frames that a trap will be verified against." ::= { thresholdLev1Entry 6 } thresholdLev1SampleType OBJECT-TYPE SYNTAX INTEGER { other(1), event-per-second(2) } ACCESS read-write STATUS optional DESCRIPTION "The method of sampling the selected variable and calculating the value to be compared against the threshold." ::= { thresholdLev1Entry 7 } thresholdLev1StartupAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), rising(2), falling(3), rising-or-falling(4) } ACCESS read-write STATUS optional DESCRIPTION "When the trap is triggered in relation to value set. When goes above (2), below (3), or changes at all from (4)." ::= { thresholdLev1Entry 8 } thresholdLev1WaterMark OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "Counter of threshold." ::= { thresholdLev1Entry 9 } thresholdLev1DetectedValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The value of the statistic for the last sampling period." ::= { thresholdLev1Entry 10 } thresholdLev1RisingEvent OBJECT-TYPE SYNTAX INTEGER { other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6) } ACCESS read-write STATUS optional DESCRIPTION "How to respond to a triggered event for a rising event." ::= { thresholdLev1Entry 11 } thresholdLev1FallingEvent OBJECT-TYPE SYNTAX INTEGER { other(1), partition-port(2), send-trap(3), partition-port-and-send-trap(4), send-trap-and-request-page(5), partition-port-and-send-trap-and-request-page(6) } ACCESS read-write STATUS optional DESCRIPTION "How to respond to a triggered event for a falling event." ::= { thresholdLev1Entry 12 } thresholdLev1Interval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The interval in seconds over which the data is sampled." ::= { thresholdLev1Entry 13 } thresholdLev1OwnerString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-write STATUS optional DESCRIPTION "8-byte octet reserved for the owner who defined this entry." ::= { thresholdLev1Entry 14 } adapterProductId OBJECT IDENTIFIER ::= { productId 1 } concProductId OBJECT IDENTIFIER ::= { productId 2 } hub1012 OBJECT IDENTIFIER ::= { concProductId 1 } -- Traps for use by Asante products -- Traps are defined using the conventions in RFC1215. -- threshold trap thresholdLev1 TRAP-TYPE ENTERPRISE asante VARIABLES { thresholdLev1Target, thresholdLev1GroupIndex, thresholdLev1PortIndex, thresholdLev1Subject, thresholdLev1SampleType, thresholdLev1WaterMark, thresholdLev1DetectedValue, thresholdLev1OwnerString, thresholdLev1RisingEvent, thresholdLev1FallingEvent } DESCRIPTION "The SNMP trap that is generated when an alarm entry crosses its rising threshold or falling threshold, and generates an event that is configured for sending SNMP traps." ::= 1 -- node intrusion trap nodeSecuLevel1 TRAP-TYPE ENTERPRISE asante -- VARIABLES { -- nodeSecuLev1GrpIndex, -- nodeSecuLev1PortIndex, -- rptrAddrLastSourceAddress, -- nodeSecuLev1Action } DESCRIPTION "The SNMP trap that is generated when the MAC layer address of the incoming frame from a particular port does not match the pre-assigned address with that port, and generates an event that is configured for sending SNMP traps." ::= 2 END