SLED-MIB device MIB details by Cable Television Laboratories Inc
SLED-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing SLED-MIB.
Vendor: | Cable Television Laboratories Inc |
---|---|
Mib: | SLED-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
SLED-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, Integer32, OBJECT-TYPE FROM SNMPv2-SMI TruthValue, TimeStamp FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF clabProjDocsis FROM CLAB-DEF-MIB InterfaceIndex FROM IF-MIB ; sledMib MODULE-IDENTITY LAST-UPDATED "200312300000Z" -- December 30, 2003 ORGANIZATION "eDOCSIS Working Group" CONTACT-INFO "John Eng Postal: Cable Television Laboratories, Inc 400 Centennial Parkway Louisville, CO 80027 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com" DESCRIPTION "This MIB module provides the management objects necessary to configure and invoke the Software Loopback Application for eDOCSIS (SLED) functionality. " REVISION "200312300000Z" -- December 30, 2003 DESCRIPTION "Initial version of the ITU-T eDOCSIS SLED MIB module. Acknowledgement: Greg Nakanishi of Motorola, Inc. " ::= { clabProjDocsis 13 } -- Administrative assignments sledNotifications OBJECT IDENTIFIER ::= { sledMib 0} sledMibObjects OBJECT IDENTIFIER ::= { sledMib 1 } sledMibNotificationsObjects OBJECT IDENTIFIER ::= { sledMib 2 } sledMibConformance OBJECT IDENTIFIER ::= { sledMib 3 } -- Object Groups sledGlobal OBJECT IDENTIFIER ::= { sledMibObjects 1 } sledLoopback OBJECT IDENTIFIER ::= { sledMibObjects 2 } sledPktGen OBJECT IDENTIFIER ::= { sledMibObjects 3 } -- -- The following group describes the objects that apply to -- both loopback and packet generator SLED functionality -- sledGlobalEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the SLED functionality to be enabled/disabled. This object may only be updated prior to device registration. If the device has completed registration, any attempt to update the value of this object returns 'notWritable'. Prior to registration, if the value of this object is set to 'true', the SLED functionality is enabled and access to this MIB is allowed. Prior to registration, if the value of this object is set to 'false', the SLED functionality is disabled and any attempt to update other objects in this MIB returns 'noAccess'. " DEFVAL {false} ::= { sledGlobal 1 } -- -- The following group describes the loopback objects -- sledLoopbackInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the logical CPE interface (LCI) that the SLED loopback function is attached to. If the index does not correspond to a LCI supported by this device, 'wrongValue' is returned. Any attempt to set this object while sledLoopbackEnable is set to 'true' returns 'notWritable'." ::= { sledLoopback 1 } sledLoopbackEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'true' enables the loopback function. Setting this object to 'false' disables the loopback function. When enabled, all Ethernet packets received by the SLED from the LCI are processed as follows: 1. If the received Ethernet packet is greater than 1472 octets, the Ethernet packet is split into two fragments, the first consisting of the first 1472 octets of the Ethernet packet and the second containing the remaining octets, resulting in two payloads that are processed as described below. If the received Ethernet packet is less than or equal to 1472 octets, the entire packet will be processed as a single payload. 2. For each payload generated in step 1, the payload is appended to the contents of sledLoopbackPktHdr. 3. The mutable fields within sledLoopbackPktHdr MUST be recomputed. The mutable fields are IP Header Checksum, IP Total Length , UDP Checksum, and UDP Length. 4. If the Ethernet packet was fragmented in step 1, the appropriate IP header fields (Flags and Fragment Offset) are updated to indicate IP fragmentation These IP fragmentation header values will differ depending on if this is the first or second fragment being processed. 5. The Ethernet FCS is computed and appended. 6. The resulting Ethernet packet is transmitted to the LCI." DEFVAL {false} ::= { sledLoopback 2 } sledLoopbackPktHdr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(42)) MAX-ACCESS read-write STATUS current DESCRIPTION "A properly formatted Ethernet(DIX)+IP+UDP headers for use in SLED loopback processing as described in sledLoopbackEnable. The object value contains mutable fields that are recomputed: the IP Header Checksum, IP Total Length, UDP Length,and UDP Checksum. Any attempt to set this object while sledLoopbackEnable is set to 'true' returns 'notWritable'" ::= { sledLoopback 3 } -- -- The following group describes the packet generation objects -- sledPktGenInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the logical CPE interface (LCI) that the SLED packet generation function is attached to. If the index does not correspond to a LCI supported by the device, 'wrongValue' is returned. Any attempt to set this object while sledPktGenTrigger is set to 'start' returns 'notWritable'" ::= { sledPktGen 1 } sledPktGenPayload OBJECT-TYPE SYNTAX OCTET STRING (SIZE(64..1518)) MAX-ACCESS read-write STATUS current DESCRIPTION "The properly formatted Ethernet packet payload to be generated. Any attempt to set this object while sledPktGenTrigger is set to 'start' returns 'notWritable'" ::= { sledPktGen 2 } sledPktGenRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The packet rate (in packets per second) that the SLED is to transmit the packet specified in the sledPktGenPayload. Any attempt to set this object while sledPktGenTrigger is set to 'start' returns 'notWritable'" DEFVAL {10} ::= { sledPktGen 3 } sledPktGenNumPkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of packets to be generated at the rate specified by sledPktGenRate. Any attempt to set this object while sledPktGenTrigger has been set to 'start' will return 'notWritable'" DEFVAL {1} ::= { sledPktGen 4 } sledPktGenTrigger OBJECT-TYPE SYNTAX INTEGER { start(1), stop(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the packet generation. Setting this object to 'start' causes the packet generation to begin. Reading this object will return 'start' if a packet generation is in progress, otherwise it will return 'stop'. Setting this object to 'stop' while packet generation is in progress aborts the packet generation. Setting this object to 'start' while packet generation is in progress, 'wrongValue' is returned." DEFVAL {stop} ::= { sledPktGen 5 } sledPktGenLastTrigger OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Value of sysUptime when the packet generation was last triggered." ::= { sledPktGen 6 } -- Conformance information ******************************************* sledMibCompliances OBJECT IDENTIFIER ::= { sledMibConformance 1 } sledMibGroups OBJECT IDENTIFIER ::= { sledMibConformance 2 } -- Compliance statements sledMibCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SLED." MODULE -- unconditionally mandatory groups MANDATORY-GROUPS { sledMibBaseGroup } ::= { sledMibCompliances 1 } sledMibBaseGroup OBJECT-GROUP OBJECTS { sledGlobalEnable, sledLoopbackInterface, sledLoopbackEnable, sledLoopbackPktHdr, sledPktGenInterface, sledPktGenPayload, sledPktGenRate, sledPktGenNumPkts, sledPktGenTrigger, sledPktGenLastTrigger } STATUS current DESCRIPTION "Group of object in SLED MIB" ::= { sledMibGroups 1 } END