CAT2600-MIB device MIB details by Cisco
CAT2600-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CAT2600-MIB.
Vendor: | Cisco |
---|---|
Mib: | CAT2600-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CAT2600-MIB DEFINITIONS ::= BEGIN -- Catalyst 2600 TokenRing Switch MIB Release 2.0 -- Copyright 1995, 1996 by Cisco and others. All rights reserved. -- This SNMP Management Information Specification embodies -- Cisco intellectual property. Cisco retains all rights, title -- and ownership in the Specification including any revisions. -- It is Cisco's intent to encourage the widespread use of -- this specification in connection with the management of -- Cisco products. Cisco grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this specification in connection with the management -- of Cisco products. -- This Specification is supplied "AS IS", Cisco makes no warranty, -- either expressed or implied, as to the use, operation, condition, -- or performance of the Specification. IMPORTS TimeTicks, IpAddress, Counter, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; -- MAC address MacAddr ::= OCTET STRING (SIZE(6)) -- Bridge ID from RFC1493 for Domain version of STP support -- BridgeId ::= OCTET STRING (SIZE(8)) cisco OBJECT IDENTIFIER ::= { enterprises 9} catProd OBJECT IDENTIFIER ::= { cisco 1 } cat2600 OBJECT IDENTIFIER ::= { catProd 111 } --Entry for Catalyst TokenRing Switch cat2600Ts OBJECT IDENTIFIER ::= { cat2600 1 } cat2600TsObjectID OBJECT IDENTIFIER ::= { cat2600Ts 1 } -- Managed Objects cat2600TsObjects OBJECT IDENTIFIER ::= { cat2600Ts 2 } dtrMIBs OBJECT IDENTIFIER ::= { cat2600Ts 3 } dtrConcMIB OBJECT IDENTIFIER ::= { dtrMIBs 1 } dtrMacMIB OBJECT IDENTIFIER ::= { dtrMIBs 2 } -- Managed Groups in this module cat2600TsMain OBJECT IDENTIFIER ::= { cat2600TsObjects 1 } cat2600TsConfig OBJECT IDENTIFIER ::= { cat2600TsMain 1 } cat2600TsSys OBJECT IDENTIFIER ::= { cat2600TsMain 2 } cat2600TsPort OBJECT IDENTIFIER ::= { cat2600TsObjects 2 } cat2600TsDmns OBJECT IDENTIFIER ::= { cat2600TsObjects 3 } cat2600TsPipe OBJECT IDENTIFIER ::= { cat2600TsObjects 4 } cat2600TsFilter OBJECT IDENTIFIER ::= { cat2600TsObjects 5 } cat2600TsUFC OBJECT IDENTIFIER ::= { cat2600TsObjects 6 } -- ================================================================== -- System Object ID cat2600TsSysObjectID OBJECT IDENTIFIER ::= { cat2600TsObjectID 1 } -- ====================================================================== -- Configuration Group cat2600TsFwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version in the form major.minor. For port microcode (SOLO) version information see the mgmt.mib-2.interfaces.ifTable.ifEntry.ifDescr object." ::= { cat2600TsConfig 1 } cat2600TsHwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The hardware version in the form major.minor." ::= { cat2600TsConfig 2 } cat2600TsSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "System serial number." ::= { cat2600TsConfig 3 } cat2600TsInstallationDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-write STATUS mandatory DESCRIPTION "Firmware installation date. This date is initially set by the Network Management station. Each time the NV RAM is cleared through the console this date needs to be set by the management station. This should be in the format YYYY MM DD HH MM SS." ::= { cat2600TsConfig 4 } cat2600TsFwSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size in bytes of the binary firmware image." ::= { cat2600TsConfig 5 } cat2600TsFwCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Firmware binary image CRC value." ::= { cat2600TsConfig 6 } cat2600TsFwManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware manufacturer." ::= { cat2600TsConfig 7 } -- The IP address and network information below relates to the entire -- switch. Note that each Domain (CRF) also has an address independent -- of those below. cat2600TsIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the switch. Changes to this object take effect immediately." ::= { cat2600TsConfig 8 } cat2600TsNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP subnet mask of the switch. Changes to this object take effect immediately." ::= { cat2600TsConfig 9 } cat2600TsDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP default gateway used by the switch. Changes to this object take effect immediately." ::= { cat2600TsConfig 10 } cat2600TsTrapRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of managers to which to send traps. Entries in the table are saved across resets and power cycles." ::= { cat2600TsConfig 14 } cat2600TsTrapRcvrEntry OBJECT-TYPE SYNTAX Cat2600TsTrapRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the trap receiver table. The column cat2600TsTrapRcvrStatus is used to create and delete rows in the table. Creation requires a SET PDU with objects cat2600TsTrapRcvrStatus, cat2600TsTrapRcvrIpAddress, and cat2600TsTrapRcvrComm." INDEX { cat2600TsTrapRcvrIndex } ::= { cat2600TsTrapRcvrTable 1 } Cat2600TsTrapRcvrEntry ::= SEQUENCE { cat2600TsTrapRcvrIndex INTEGER, cat2600TsTrapRcvrStatus INTEGER, cat2600TsTrapRcvrIpAddress IpAddress, cat2600TsTrapRcvrComm DisplayString, cat2600TsTrapRcvrDmns OCTET STRING } cat2600TsTrapRcvrIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the row in the table." ::= { cat2600TsTrapRcvrEntry 1 } cat2600TsTrapRcvrStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following valid(2), -- a valid address invalid(3), -- an invalid address create(4) -- create row } ACCESS read-write STATUS mandatory DESCRIPTION "Setting the value of this object to invalid(3) deletes the row from the table. The value invalid(3) should never be returned on a GET. Setting this value to create(4) causes a new row to be created if the row does not already exist. To create a new row set cat2600TsTrapRcvrStatus to create(4) and cat2600TsTrapRcvrIndex to the next available index ( cat2600TsTrapRcvrNext ). After successful creation of the new row, you can then set the desired values for cat2600TsTrapRcvrIpAddress and cat2600TsTrapRcvrComm. The value returned on GETs should be valid(2) or other(1), which is used to indicate any other condition." ::= { cat2600TsTrapRcvrEntry 2 } cat2600TsTrapRcvrIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address for an SNMP manager that is to receive the trap." ::= { cat2600TsTrapRcvrEntry 3 } cat2600TsTrapRcvrComm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write -- ?? WRITE-ONLY ?? STATUS mandatory DESCRIPTION "Community string to use." ::= { cat2600TsTrapRcvrEntry 4 } cat2600TsTrapRcvrDmns OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-write STATUS mandatory DESCRIPTION "Domains on which traps to this target are sent. Each octet within the value of this object specifies a set of eight domains, with the first octet specifying domains 0 through 7, the second octet specifying domains 8 through 15, etc. Within each octet, the most significant bit represents the lowest numbered domain, and the least significant bit represents the highest numbered domain. Thus, each domain is represented by a single bit within the value of this object. If that bit has a value of '1' then that domain is included in the set of ports which will receive the trap; the domain is not included if its bit has a value of '0'." ::= { cat2600TsTrapRcvrEntry 5 } cat2600TsPingInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable specifies the interval in seconds of sending ICMP Echo Requests to the default gateway. No PING packets will be sent if the value is set to 0. The default interval is 10 minutes." DEFVAL { 600 } ::= { cat2600TsConfig 19 } cat2600TsTapPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Select the port to monitor traffic." ::= { cat2600TsConfig 20 } cat2600TsTapMonitoredPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Allows the selection of the port that will be monitored by the port selected by cat2600TsTapPort." ::= { cat2600TsConfig 21 } cat2600TsCrcThresholdHi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Threshold for the switch to change to store and forward mode. A change in mode also generates a trap." ::= { cat2600TsConfig 22 } cat2600TsCrcThresholdLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Threshold for the switch to change to store and forward mode. A change in mode also generates a trap." ::= { cat2600TsConfig 23 } cat2600TsPortSwitchModeChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the trap sent out when the switching mode changes from cut-through to store and forward." ::= { cat2600TsConfig 24 } cat2600TsTrendThreshold OBJECT-TYPE SYNTAX INTEGER -- ??(1..100)?? ACCESS read-write STATUS mandatory DESCRIPTION "Based on trend calculation of the Dynamic Cut State algorithm, when this value is exceeded the port changes from cut-through to store and forward mode. The default value for this object is 8 events. The valid range is 1-100." ::= { cat2600TsConfig 25 } cat2600TsSamplingPeriod OBJECT-TYPE SYNTAX INTEGER (1 ..120) ACCESS read-write STATUS mandatory DESCRIPTION "Sampling period in minutes for determining if the error rate of CRC errors has been exceeded. The default value for this object is 10 minutes. The valid range is 1-120." ::= { cat2600TsConfig 26 } cat2600TsNumberUFC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of UFCs installed in the switch. A value of zero (or an SNMP error of NOSUCH) indicates there are NO UFCs installed in this switch. This value indicates the number of entries in the cat2600TsUFCTable." ::= { cat2600TsConfig 27 } -- ==================================================================== -- System Module objects cat2600TsNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of physical ports on the switch. This value includes all base ports plus all ports on any UFC cards. It does not include internally defined Bridge Relay Function ports or the CPU 'interface'." ::= { cat2600TsSys 1 } cat2600TsNumStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Aggregate number of currently active stations (nodes) on all ports on the switch." ::= { cat2600TsSys 2 } cat2600TsMostStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations ever active on all ports at one time, since the last reset or power cycle. This includes the default MAC address entries from each port." ::= { cat2600TsSys 3 } cat2600TsMaxStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations which the switch can support simultaneously." ::= { cat2600TsSys 4 } cat2600TsReset OBJECT-TYPE SYNTAX INTEGER { running(1), -- switch is running hardReset(2), -- do hard reset of switch softReset(3) -- do soft reset of switch } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to reset the switch. Writing softReset(3) causes the switch to reset the hardware, run quick diagnostics, clear all counters, start switching, issue a warmstart trap, and then be able to respond to SNMP requests. Writing hardReset(2) causes the switch to run power up diagnostics and then execute a soft reset. Note: all address tables are cleared in both cases. The administrative parameters from nonvolatile memory are used to initialize the operational parameters. The value returned on GETs should be running(1)." ::= { cat2600TsSys 5 } cat2600TsNumResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of soft resets the switch has executed since the last hard reset or power cycle. Soft resets are defined as writing softReset(3) to cat2600TsReset, pressing the front panel reset button, executing a soft reset from the console, or resets induced by the switch firmware." ::= { cat2600TsSys 6 } cat2600TsAddrAgingTime OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Number of minutes of inactivity before an address entity is aged out. A value of zero means no aging. Note: if an address shows up on another port, the original port to address assignment is automatically deleted. The value is saved across resets and power cycles. The default value for this object is 5 minutes." ::= { cat2600TsSys 7 } cat2600TsSysTemperature OBJECT-TYPE SYNTAX INTEGER { normal (1), toohigh (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Temperature condition of the system. A change in this value generates a TRAP." ::= { cat2600TsSys 11 } cat2600TsInstalledMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total amount of CPU memory installed (in megabytes)." ::= { cat2600TsSys 12 } cat2600TsSysCurTime OBJECT-TYPE SYNTAX DisplayString (SIZE (1 .. 128)) ACCESS read-write STATUS mandatory DESCRIPTION "Current time at the switch. To set the time use the format yyyy mm dd hh mm ss. All fields are required." ::= { cat2600TsSys 13 } -- ======================================================================= -- Port level objects -- Catalyst 2600 TokenRing Switch Port table cat2600TsPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information about each port. The number of rows is given by cat2600TsNumPorts. (This value refers to PHYSICAL ports as opposed to internal logical CRF bridge ports.)" ::= { cat2600TsPort 1 } cat2600TsPortEntry OBJECT-TYPE SYNTAX Cat2600TsPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the port table. The number of rows is determined by the hardware and is specified by the value of cat2600TsNumPorts. Rows can not be created or deleted via SNMP requests." INDEX { cat2600TsPortIndex } ::= { cat2600TsPortTable 1 } Cat2600TsPortEntry ::= SEQUENCE { cat2600TsPortIndex INTEGER, cat2600TsPortRcvLocalFrames Counter, cat2600TsPortForwardedFrames Counter, cat2600TsPortMostStations Counter, cat2600TsPortMaxStations Counter, cat2600TsPortSWHandledFrames Counter, cat2600TsPortLocalStations Counter, cat2600TsPortRemoteStations Counter, cat2600TsPortUnknownStaFrames Counter, cat2600TsPortResetStats INTEGER, cat2600TsPortResetTimer TimeTicks, cat2600TsPortResetAddrs INTEGER, cat2600TsPortRcvBcasts Counter, cat2600TsPortSwitchedFrames Counter, cat2600TsPortLinkState INTEGER, cat2600TsPortHashOverflows Counter, cat2600TsPortAddrAgingTime INTEGER, cat2600TsPortSwitchMode INTEGER, cat2600TsPortFixedCfg INTEGER, cat2600TsPortMode INTEGER, cat2600TsPortDuplex INTEGER, cat2600TsPortCfgLoss INTEGER, cat2600TsPortCfgLossRC INTEGER, cat2600TsPortCRCCount Counter, cat2600TsPortHPChannelFrames Counter, cat2600TsPortLPChannelFrames Counter, cat2600TsPortHPThreshold INTEGER, cat2600TsPortCfgRingSpeed INTEGER, cat2600TsPortCfgRSA INTEGER, cat2600TsPortDomain INTEGER, cat2600TsPortCfgLossThreshold INTEGER, cat2600TsPortCfgLossSamplingPeriod INTEGER, cat2600TsPortBeaconStationAddress MacAddr, cat2600TsPortBeaconNAUN MacAddr, --cat2600TsPortBeaconRecoveryStatus INTEGER cat2600TsPortBeaconType INTEGER } cat2600TsPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value corresponding to each port entry. For TR interfaces, the TsPortIndex corresponds to the Port Number or POE Index." ::= { cat2600TsPortEntry 1 } cat2600TsPortRcvLocalFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received where the destination is on this port." ::= { cat2600TsPortEntry 2 } cat2600TsPortForwardedFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received on this port and forwarded to another port or the system module for processing." ::= { cat2600TsPortEntry 3 } cat2600TsPortMostStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Highest number of stations ever active at any time since the last reset of the switch as seen by this port. This includes the default MAC address entries for the port." ::= { cat2600TsPortEntry 4 } cat2600TsPortMaxStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of stations which the port can support simultaneously." ::= { cat2600TsPortEntry 5 } cat2600TsPortSWHandledFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Frames received on this port and delivered to the system module for processing." ::= { cat2600TsPortEntry 6 } cat2600TsPortLocalStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of stations on this port's address table which belong to the segment attached to this port." ::= { cat2600TsPortEntry 7 } cat2600TsPortRemoteStations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of stations on this port's address table which belong to segments attached to other ports." ::= { cat2600TsPortEntry 8 } cat2600TsPortUnknownStaFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of unicast frames received on this port and forwarded to the system module for processing because the source or destination station address is not in the port's forwarding table." ::= { cat2600TsPortEntry 9 } cat2600TsPortResetStats OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following running(2), -- port is functioning reset(3) -- reset port counters } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to reset(3) causes all traffic counters for this port to be set to zero. Also the value of cat2600TsPortResetTimer is set to zero." ::= { cat2600TsPortEntry 10 } cat2600TsPortResetTimer OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time (in 100th second ticks) since the port counters were reset." ::= { cat2600TsPortEntry 11 } cat2600TsPortResetAddrs OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following running(2), -- port is functioning reset(3) -- clear address table & reset port counters } -- (state returns to running (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to reset(3) clears all address table entries for this port as well as setting all port traffic counters to zero and setting cat2600TsPortResetTimer to zero." ::= { cat2600TsPortEntry 12 } cat2600TsPortRcvBcasts OBJECT-TYPE SYNTAX Counter -- ?? RFC1573 bcst frames ?? ACCESS read-only STATUS mandatory DESCRIPTION "Number of Broadcast Frames received on this port without errors." ::= { cat2600TsPortEntry 13 } cat2600TsPortSwitchedFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames switched on this port" ::= { cat2600TsPortEntry 14 } cat2600TsPortLinkState OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Link state of the port." ::= { cat2600TsPortEntry 15 } cat2600TsPortHashOverflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times a hash bucket was full when trying to add an entry to the port address table." ::= { cat2600TsPortEntry 16 } cat2600TsPortAddrAgingTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port level address aging time." ::= { cat2600TsPortEntry 17 } cat2600TsPortSwitchMode OBJECT-TYPE SYNTAX INTEGER { storeandforward (1), cutthru (2) , auto (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Operational frame switching mode for the port. When in auto mode the port uses the Direct Cut algorithm to place the port in either cut-thru or store-and- forward mode. This object is equivalent to cPortProtocolCharFrameControlOption in the dtrMac MIB. However, this object defines an additional state -auto- not defined in that standard." ::= { cat2600TsPortEntry 18 } cat2600TsPortFixedCfg OBJECT-TYPE SYNTAX INTEGER { auto-detect (1), fixed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Use fixed configuration or run auto detection to determine configuration. " ::= { cat2600TsPortEntry 19 } cat2600TsPortMode OBJECT-TYPE SYNTAX INTEGER { adapter (1), port (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When read, this object indicates the Port Mode obtained by the auto-detect function. It is a valid read object only when TsPortFixedCfg is set to auto-detect(1) and TsPortLinkState indicates up(1). Write to this object when defining the Port Mode for a fixed configuration (TsPortFixedCfg set to fixed(2)). This object is equivalent to the dtrMac MIB object cPortProtocolCharOperationOption." ::= { cat2600TsPortEntry 20 } cat2600TsPortDuplex OBJECT-TYPE SYNTAX INTEGER { half-duplex (1), full-duplex (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Version 1 MIB When read, this object indicates the Port Duplex state obtained by the auto-detect function. This object is a valid read object any time that TSPortLinkState indicates up(1) or when TsPortFixedCfg indicates fixed(2). Write to this object when defining the Port Duplex state for a fixed configuration (TsPortFixedCfg set to fixed(2)). Version 2 MIB This object is related to the dtrMac MIB objects cPortProtocolCharCurrentAccessProtocol and cPortProtocolCharAccessProtcolMask as defined in the following table: TsPortLinkState | TsPortFixedCfg | TsPortDuplex equivalent to: | | down | auto | CPortProtocolCharAccess | | ProtocolMask = X'0003' | | down | fixed | CPortProtocolCharAccess | | ProtocolMask = X'0001' or | | = X'0002' | | up | auto | cPortProtocolCharCurrent | | AccessProtocol | | up | fixed | cPortProtocolCharCurrent | | AccessProtocol." ::= { cat2600TsPortEntry 21 } cat2600TsPortCfgLoss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of events as described in TsPortCfgLossRC after the port has completed the join process and then lost communication." ::= { cat2600TsPortEntry 22 } cat2600TsPortCfgLossRC OBJECT-TYPE SYNTAX INTEGER { wire-fault(1), beacon-auto-removal (2), force-remove-macaddr (3), connection-lost (4), adapter-check (5), close-srb (6), fdx-protocol-failure (7) } ACCESS read-only STATUS mandatory DESCRIPTION "Reason code describing the cause of configuration loss." ::= { cat2600TsPortEntry 23 } cat2600TsPortCRCCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with CRC error. This object is equivalent to dot5StatsLineError and to the dtrMac MIB object txiStatsLineErrorCounter." ::= { cat2600TsPortEntry 24 } cat2600TsPortHPChannelFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent to the high priority channel of the particular Token-Ring port." ::= { cat2600TsPortEntry 25 } cat2600TsPortLPChannelFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent to the low priority channel of the particular Token-Ring port." ::= { cat2600TsPortEntry 26 } cat2600TsPortHPThreshold OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Priority level at which frames are sent to the High priority channel." DEFVAL { 4 } ::= { cat2600TsPortEntry 27 } cat2600TsPortCfgRingSpeed OBJECT-TYPE SYNTAX INTEGER { speed-16megabit (1), speed-4megabit (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When read this object indicates the Port Ring Speed obtained by the RSA function. Write to this object when defining the Port Ring Speed for a fixed configuration (TsPortCfgRSA set to fixed(2)). When TsPortCfgRSA indicates fixed(2), this object is equivalent to the dtrMac MIB object cPortProtocolCharMediumRateOption and to dot5RingSpeed. Note that the syntax of these objects is different. For cPortProtocolCharMediumRateOption 1 indicates 4 Mb/s, while for TsPortCfgRingSpeed 1 indicates 16Mb/s. This object is a valid read object any time that TSPortLinkState indicates up(1)or when TsPortCfgRSA indicates fixed(2)." ::= { cat2600TsPortEntry 28 } cat2600TsPortCfgRSA OBJECT-TYPE SYNTAX INTEGER { rsa (1), fixed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "User configured Ring Speed Adjust or fixed speed." ::= { cat2600TsPortEntry 29 } cat2600TsPortDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Domain that the port belongs to." ::= { cat2600TsPortEntry 30 } cat2600TsPortCfgLossThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of configuration loss events (described in TsPortCfgLossRC) during the sample period which, if exceeded, should cause the port to be disabled. If the port is disabled by this function the port must be manually re-enabled." ::= { cat2600TsPortEntry 31 } cat2600TsPortCfgLossSamplingPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The sampling period, in minutes, for which the port monitors to see if the configuration loss threshold has been exceeeded." ::= { cat2600TsPortEntry 32 } -- The information below is intended for the generation of SNMP -- TRAPS and should not be used to determine the health of the -- network or system cat2600TsPortBeaconStationAddress OBJECT-TYPE SYNTAX MacAddr ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC address of the Station last generating a beacon MAC frame. This information is present for the generation of a trap and should not be used to represent the health of the ring." ::= { cat2600TsPortEntry 33 } cat2600TsPortBeaconNAUN OBJECT-TYPE SYNTAX MacAddr ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC address of the NAUN station last generating a beacon MAC frame. This information is present for the generation of a trap and should not be used to represent the health of the ring." ::= { cat2600TsPortEntry 34 } cat2600TsPortBeaconType OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The type of Beacon which last occurred. Values are the same as for the Beacon Type subvector and are defined as follows: X'0001' Issued by a Dual Ring Station during reconfiguration X'0002' Signal Loss X'0003' Timer TCT expired during claim token; no claim token frames recieved X'0004' Timer TCT expired during claim token; claim token frames recieved X'0005' TXI Access Protocol; Heart Beat Protocol Failure " ::= { cat2600TsPortEntry 35 } -- cat2600TsPortBeaconRecoveryStatus OBJECT-TYPE -- SYNTAX INTEGER { -- noneLeft(1), -- beaconingStationLeft(2), -- naunStationLeft(3), -- bothStationsLeft(4), -- invalid(5) -- } -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "This object indicates which station in the beacon fault domain -- was removed as part of the automatic recovery process. -- (1) noneLeft -- (2) beaconingStationLeft -- (3) naunStationLeft -- (4) bothStationsLeft. -- (5) invalid. -- This information is present for the generation of a trap and -- should not be used to represent the health of the ring." -- ::= { cat2600TsPortEntry 36 } -- ======================================================================= -- TokenRing Switch Port station table cat2600TsPortStnTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsPortStnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port station table." ::= { cat2600TsPort 3 } cat2600TsPortStnEntry OBJECT-TYPE SYNTAX Cat2600TsPortStnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of rows in the port table. The number of rows is determined by the hardware and is specified by the value of cat2600TsNumPorts. Rows can not be created or deleted via SNMP requests." INDEX { cat2600TsPortStnPortNum, cat2600TsPortStnAddress } ::= { cat2600TsPortStnTable 1 } Cat2600TsPortStnEntry ::= SEQUENCE { cat2600TsPortStnPortNum INTEGER, cat2600TsPortStnAddress MacAddr, cat2600TsPortStnLocation INTEGER, cat2600TsPortStnSrcFrames Counter, cat2600TsPortStnSrcBytes Counter, cat2600TsPortStnDestnFrames Counter, cat2600TsPortStnDestnBytes Counter } cat2600TsPortStnPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number corresponding to this entry." ::= { cat2600TsPortStnEntry 1 } cat2600TsPortStnAddress OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "Station MAC address. Equivalent to ifPhysAddr for this port." ::= { cat2600TsPortStnEntry 2 } cat2600TsPortStnLocation OBJECT-TYPE SYNTAX INTEGER {local (1), remote (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Where the station is located." ::= { cat2600TsPortStnEntry 3 } cat2600TsPortStnSrcFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with this station as the source." ::= { cat2600TsPortStnEntry 4 } cat2600TsPortStnSrcBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Bytes with this station as the source." ::= { cat2600TsPortStnEntry 5 } cat2600TsPortStnDestnFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames with this station as the destination." ::= { cat2600TsPortStnEntry 6 } cat2600TsPortStnDestnBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes with this station as the destination." ::= { cat2600TsPortStnEntry 7 } -- ======================================================================== -- "optimized" port station table cat2600TsOptPortStaTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsOptPortStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved." ::= { cat2600TsPort 2 } cat2600TsOptPortStaEntry OBJECT-TYPE SYNTAX Cat2600TsOptPortStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of the rows in the optimized port station address table. Rows can not be created or deleted via SNMP requests." INDEX { cat2600TsPortIndex, cat2600TsOptPortStaPos } ::= { cat2600TsOptPortStaTable 1 } Cat2600TsOptPortStaEntry ::= SEQUENCE { cat2600TsOptPortStaPos INTEGER, cat2600TsOptPortStaVal OCTET STRING } cat2600TsOptPortStaPos OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Second index for items in the optimized port station address table." ::= { cat2600TsOptPortStaEntry 1 } cat2600TsOptPortStaVal OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "An OCTET STRING containing a multiple number of stations from a port station address table. Each entry is encoded in the following format: Station MAC address - 6 octets Location 1 - local 2 - remote - 1 octet Port of exit Mask - 4 octets Source Frame Count - 4 octets (integer in little endian) Destn Frame Count - 4 octets (integer in little endian) Source Byte Count - 4 octets (integer in little endian) Destn Byte Count - 4 octets (integer in little endian) The Port of exit mask is encoded in its raw form as stored in the switch. Octet 1 Bit position 7 6 5 4 3 2 1 0 Port Number 31 30 29 28 27 26 25 24 Octet 2 Bit position 7 6 5 4 3 2 1 0 Port Number 23 22 21 20 19 18 17 16 Octet 3 Bit position 7 6 5 4 3 2 1 0 Port Number 15 14 13 12 11 10 9 8 Octet 4 Bit position 7 6 5 4 3 2 1 0 Port Number 7 6 5 4 3 2 1 CPU " ::= { cat2600TsOptPortStaEntry 2 } -- ======================================================================= -- Domain configuration objects -- The term "Domain" used in the following section should be -- considered to be equivalent to the term "Concetrator Relay -- Function" (CRF) as defined in ISO/IEC 8802-5 Dedicated Token Ring -- Draft Standard 802.5r Annex K. -- The configuration information in the following section extends -- the information provided in the CRF configuration values of -- the dtrConc MIB. -- Domain table cat2600TsDmnTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsDmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Currently active domains on the switch." ::= { cat2600TsDmns 1 } cat2600TsDmnEntry OBJECT-TYPE SYNTAX Cat2600TsDmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the domain Table" INDEX { cat2600TsDmnIndex } ::= { cat2600TsDmnTable 1 } Cat2600TsDmnEntry ::= SEQUENCE { cat2600TsDmnIndex INTEGER, cat2600TsDmnPorts OCTET STRING, cat2600TsDmnIpState INTEGER, cat2600TsDmnIpAddress IpAddress, cat2600TsDmnIpSubnetMask IpAddress, cat2600TsDmnIpDefaultGateway IpAddress, cat2600TsDmnStp INTEGER, cat2600TsDmnName DisplayString, cat2600TsDmnIfIndex INTEGER, cat2600TsDmnBaseBridgeAddr MacAddr, cat2600TsDmnNumStations INTEGER, cat2600TsDmnMostStations INTEGER } cat2600TsDmnIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Domain number for each row." ::= { cat2600TsDmnEntry 1 } cat2600TsDmnPorts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports that belong to this Domain. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the TokenRing Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. Warning: You will not receive a set- complete message as a set to this object causes the ports to reset." ::= { cat2600TsDmnEntry 2 } cat2600TsDmnIpState OBJECT-TYPE SYNTAX INTEGER { disabled (1), auto-bootp(2), always-bootp (3) } ACCESS read-write STATUS mandatory DESCRIPTION "IP configuration method for this domain." ::= { cat2600TsDmnEntry 3 } cat2600TsDmnIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of this Domain. Changes to this object will take effect immediately." ::= { cat2600TsDmnEntry 4 } cat2600TsDmnIpSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The subnet mask for this domain. Changes to this object will take effect immediately." ::= { cat2600TsDmnEntry 5 } cat2600TsDmnIpDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the default gateway for this Domain. Changes to this object will take effect immediately." ::= { cat2600TsDmnEntry 6 } cat2600TsDmnStp OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn Spanning tree on or off. Changes to this object will take effect immediately. The Spanning Tree Objects themselves are in the dtrConc MIB." ::= { cat2600TsDmnEntry 7 } cat2600TsDmnName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) ACCESS read-write STATUS mandatory DESCRIPTION "User assigned name for each domain." ::= { cat2600TsDmnEntry 8 } cat2600TsDmnIfIndex OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex of the interface entry corresponding to each configured domain." ::= { cat2600TsDmnEntry 9 } cat2600TsDmnBaseBridgeAddr OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "Base MAC address of this domain. Internally equivalent to dtrCRFMacAddress and to ifPhysAddress of the 'Domain' port." ::= { cat2600TsDmnEntry 10 } cat2600TsDmnNumStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Aggregate number of currently active stations (nodes) on all ports in the domain." ::= { cat2600TsDmnEntry 11 } cat2600TsDmnMostStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest aggregate number of stations ever active on all ports at one time, since the last reset or power cycle." ::= { cat2600TsDmnEntry 12 } -- ====================================================================== -- Domains Station Table -- Information in the Domains Station Table corresponds to information -- in the dtrConc MIB Filtering Data Base. Stations learned in each -- Domain are placed into the 'Dynamic' filtering database while -- pre-defined station addresses are in the 'Static' filtering database. cat2600TsDmnStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsDmnStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Stations seen in each domain." ::= { cat2600TsDmns 5 } cat2600TsDmnStationEntry OBJECT-TYPE SYNTAX Cat2600TsDmnStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the domain specific station table. The object is equivalent to dtrFdbDynamicAddrTable or dtrFdbStaticAddrTable depending if the entry is learned or is a configured filter." INDEX { cat2600TsDmnIndex, cat2600TsDmnStationAddress } ::= { cat2600TsDmnStationTable 1 } Cat2600TsDmnStationEntry ::= SEQUENCE { cat2600TsDmnStationDmnIndex INTEGER, cat2600TsDmnStationAddress OCTET STRING, cat2600TsDmnStationPort INTEGER, cat2600TsDmnStationTraffic OCTET STRING } cat2600TsDmnStationDmnIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Integer reference to the domain number in the domain table." ::= { cat2600TsDmnStationEntry 1 } cat2600TsDmnStationAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The Station's MAC address." ::= { cat2600TsDmnStationEntry 2 } cat2600TsDmnStationPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The source port for the Station. The dtrConc MIB equivalents are dtrFdbDynamicAddrPortNumber and dtrFdbStaticAddrPortNumber." ::= { cat2600TsDmnStationEntry 3 } cat2600TsDmnStationTraffic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A bit string that identifies the ports that this station has generated traffic to or from. The bits correspond to ports, with bits and ports numbered from right to left so that bit 0 represents the CPU, bit 1 represents port 1, and so forth. For example, the returned string 01 4D can be expanded to: 00000001 01001101 binary representation of object string xxxxxxx8 7654321C ports corresponding to bits This indicates ports 8, 6, 3, 2 and the CPU. The size of this string is adjusted to include all ports with traffic." ::= { cat2600TsDmnStationEntry 4 } -- An "optimized" version of the domain station table cat2600TsOptDmnStaTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsOptDmnStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved." ::= { cat2600TsDmns 6 } cat2600TsOptDmnStaEntry OBJECT-TYPE SYNTAX Cat2600TsOptDmnStaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of the rows in the optimized domain station address table. Rows can not be created or deleted via SNMP requests." INDEX { cat2600TsDmnStationDmnIndex, cat2600TsOptDmnStaPos } ::= { cat2600TsOptDmnStaTable 1 } Cat2600TsOptDmnStaEntry ::= SEQUENCE { cat2600TsOptDmnStaPos INTEGER, cat2600TsOptDmnStaVal OCTET STRING } cat2600TsOptDmnStaPos OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Second index for items in the optimized port station address table." ::= { cat2600TsOptDmnStaEntry 1 } cat2600TsOptDmnStaVal OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "An OCTET STRING containing a multiple number of stations from the domain station address table. Each entry is encoded in the following format: Station MAC address - 6 octets Port of Entry - 1 octet Traffic Mask - 4 octets The traffic mask is encoded in its raw form as stored in the switch. Octet 1 Bit position 7 6 5 4 3 2 1 0 Port Number 31 30 29 28 27 26 25 24 Octet 2 Bit position 7 6 5 4 3 2 1 0 Port Number 23 22 21 20 19 18 17 16 Octet 3 Bit position 7 6 5 4 3 2 1 0 Port Number 15 14 13 12 11 10 9 8 Octet 4 Bit position 7 6 5 4 3 2 1 0 Port Number 7 6 5 4 3 2 1 CPU " ::= { cat2600TsOptDmnStaEntry 2 } -- =================================================================== -- TokenPipe Table. cat2600TsPipeTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsPipeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The TokenPipe table." ::= { cat2600TsPipe 1 } cat2600TsPipeEntry OBJECT-TYPE SYNTAX Cat2600TsPipeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the TokenPipe table." INDEX { cat2600TsPipeNumber } ::= { cat2600TsPipeTable 1 } Cat2600TsPipeEntry ::= SEQUENCE { cat2600TsPipeNumber INTEGER, cat2600TsPipePorts OCTET STRING } cat2600TsPipeNumber OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The TokenPipe number for this row." ::= { cat2600TsPipeEntry 1 } cat2600TsPipePorts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports in this switch which are active in this Pipe. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16 (if available), etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the NWays LAN Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { cat2600TsPipeEntry 2 } -- ======================================================================= -- Catalyst 2600 Filter table cat2600TsFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Filters set up in the switch." ::= { cat2600TsFilter 1 } cat2600TsFilterEntry OBJECT-TYPE SYNTAX Cat2600TsFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of each row in the filter table." INDEX { cat2600TsFilterStationAddress, cat2600TsFilterType } ::= { cat2600TsFilterTable 1 } Cat2600TsFilterEntry ::= SEQUENCE { cat2600TsFilterStationAddress MacAddr, cat2600TsFilterType INTEGER, cat2600TsFilterStatus INTEGER, cat2600TsFilterPorts OCTET STRING, cat2600TsFilterMask OCTET STRING } cat2600TsFilterStationAddress OBJECT-TYPE SYNTAX MacAddr ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address in a frame to which this entry's filtering information applies." ::= { cat2600TsFilterEntry 1 } cat2600TsFilterType OBJECT-TYPE SYNTAX INTEGER { source-filter (1), destination-filter (2) } ACCESS read-only STATUS mandatory DESCRIPTION "There are two types of filters (i) source filters which act on the source address portion of a packet and (ii) destination filters which act on the destination address portion of a packet." ::= { cat2600TsFilterEntry 2 } cat2600TsFilterStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the status of this entry. valid(1) - this entry is currently in use and will remain so after the next reset of the bridge. invalid(2) - writing this value to the object removes the corresponding entry." ::= { cat2600TsFilterEntry 3 } cat2600TsFilterPorts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports to which this filter is applied. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the TokenRing Switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. All frames with destination address equal to the station address corresponding to this entry and entering from any of the specified ports will be dropped. Setting this object with a MIB instance corresponding to the dotted decimal MAC address and a filter type, with the set value equal to the mask of ports you want to filter will create an entry in the table. Ex. MIB instance: 16.0.90.3.0.36.1 SNMP set value: 7F 00 00 00 This would create a filter entry with the following characteristics: MAC Address: 10 00 5A 03 00 24 (canonical format) Filter Type: source-filter Filter Ports: 2 3 4 5 6 7 8" ::= { cat2600TsFilterEntry 4 } cat2600TsFilterMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "The filter mask for this station. The semantics of the filter mask depend on the type of filter. For a source filter, the mask gives the ports that are allowed to receive frames from the filtered address. For a destination filter, the mask gives the ports that are forced to receive frames destined to the filtered address. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16 (if available), etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { cat2600TsFilterEntry 5 } -- ----------------------------------------------------------------- -- The Universal Feature Card Information -- ----------------------------------------------------------------- -- ----------------------------------------------------------------- -- The Universal Feature Card Table -- The UFC table entries occur only when UFC cards are installed -- in the switch ie when cat2600TsUFCNumber > 0. -- ----------------------------------------------------------------- cat2600TsUFCTable OBJECT-TYPE SYNTAX SEQUENCE OF Cat2600TsUFCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the installed UFC cards in the switch. The number of entries in the table is given by cat2600TsNumberofUFCs." ::= { cat2600TsUFC 1 } cat2600TsUFCEntry OBJECT-TYPE SYNTAX Cat2600TsUFCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The objects contained in the UFC table." INDEX { cat2600TsUFCSlotNum } ::= { cat2600TsUFCTable 1 } Cat2600TsUFCEntry ::= SEQUENCE { cat2600TsUFCSlotNum INTEGER, cat2600TsUFCNumPhysIfs INTEGER, cat2600TsUFCManufacturer DisplayString, cat2600TsUFCType OCTET STRING, cat2600TsUFCTypeDesc DisplayString, cat2600TsUFCHwVer DisplayString, cat2600TsUFCFwVer DisplayString, cat2600TsUFCStatus INTEGER, cat2600TsUFCReset INTEGER } cat2600TsUFCSlotNum OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the slot in which the UFC is installed." ::= { cat2600TsUFCEntry 1 } cat2600TsUFCNumPhysIfs OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of physical network interfaces on the UFC. This count does not include the interface _OF_ the card or any logical interfaces which be _ON_ the card." ::= { cat2600TsUFCEntry 2 } cat2600TsUFCManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware manufacturer." ::= { cat2600TsUFCEntry 3 } cat2600TsUFCType OBJECT-TYPE SYNTAX OCTET STRING(SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The code representing what type of UFC is present. UFC codes are assigned by Cisco." ::= { cat2600TsUFCEntry 4 } cat2600TsUFCTypeDesc OBJECT-TYPE SYNTAX DisplayString(SIZE(0..127)) ACCESS read-only STATUS mandatory DESCRIPTION "A text string describing what type of UFC is present." ::= { cat2600TsUFCEntry 5 } cat2600TsUFCHwVer OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The hardware version in the form major.minor." ::= { cat2600TsUFCEntry 6 } cat2600TsUFCFwVer OBJECT-TYPE SYNTAX DisplayString(SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware version in the form major.minor." ::= { cat2600TsUFCEntry 7 } cat2600TsUFCStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- UFC is operational down(2), -- UFC is down or reseting other(3) -- UFC is in an unknown state } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the UFC." ::= { cat2600TsUFCEntry 8 } cat2600TsUFCReset OBJECT-TYPE SYNTAX INTEGER { running(1), -- UFC is running hardReset(2), -- do hard reset of UFC softReset(3) -- do soft reset of UFC } ACCESS read-write STATUS mandatory DESCRIPTION "The object is used to reset a UFC. Writing a softReset(3) causes the switch to reset the hardware, run the minimum number of diagnostics, and clear all counters. Writing hardReset(2) causes the UFC to run power up diagnostics and then execute a softreset." ::= { cat2600TsUFCEntry 9 } END