CISCO-6200-MIB device MIB details by Cisco
CISCO-6200-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-6200-MIB.
Vendor: | Cisco |
---|---|
Mib: | CISCO-6200-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- **************************************************** -- CISCO-C6200-MIB.my: c6200 Platform Specific MIB -- -- February 1998, the dms team -- -- Copyright (c) 1998 by Cisco Systems, Inc. -- All rights reserved. -- -- **************************************************** -- Glossary of terms -- -- CAP: Carrierless Amplitude Phase Modulation -- DMT: Discrete Multitone Modulation -- DSLAM: Digital Subscriber Line ATM Multiplexor -- RADSL: Rate Adaptive Digital Subscriber Loop -- CISCO-6200-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, DisplayString, DateAndTime FROM SNMPv2-TC ciscoExperiment FROM CISCO-SMI; cisco6200MIB MODULE-IDENTITY LAST-UPDATED "9807280000Z" ORGANIZATION "Cisco System, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 West Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-c6200@cisco.com" DESCRIPTION "This MIB provides CISCO 6200 product information It is structured as following groups: system - not part of indices, defines system, slot and port level scalars." REVISION "9802260000Z" DESCRIPTION "The initial release of this MIB only supported CAP line cards." ::= { ciscoExperiment 26 } -- -- OBJECT IDENTIFIER assignment for various groups -- cisco6200MibObjects OBJECT IDENTIFIER ::= { cisco6200MIB 1 } c62System OBJECT IDENTIFIER ::= { cisco6200MibObjects 1 } c62Slot OBJECT IDENTIFIER ::= { cisco6200MibObjects 2 } c62OCInterface OBJECT IDENTIFIER ::= { cisco6200MibObjects 3 } c62LineInterface OBJECT IDENTIFIER ::= { cisco6200MibObjects 4 } c62Subscriber OBJECT IDENTIFIER ::= { cisco6200MibObjects 5 } -- -- Textual conventions -- C6200CardType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents card types contained in the C6200 product lines. oc3si - one port, single mode, intermediate reach OC3 - based interface card ctl - controller card cap8 - eight port CAP RADSL interface card cap16 - sixteen port CAP RADSL interface card oc3ss - one port, single mode, short reach OC3 based - interface card oc3mm - one port, multi mode OC3 based interface card stm1si - one port, single mode, intermediate reach STM1 based interface card stm1mm - one port, multi mode STM1 based interface card dmt8 - eight port DMT RADSL interface card none - marks slot as vacant" SYNTAX INTEGER { oc3si (1), ctl (2), cap8 (3), cap16 (4), oc3ss (5), oc3mm (6), stm1si (7), stm1mm (8), dmt8 (9), none (-1) } CommandValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This parameter controls execution of a command. The intended command can be triggered by setting its value to execute. Its value goes back to ready when intended command execution is complete." SYNTAX INTEGER { ready (1), execute (2) } AlarmLevel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents error status." SYNTAX INTEGER { none (1), minor (2), major (3), critical (4), unknown (5) } InterfaceStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents interface status." SYNTAX INTEGER { enabled (1), disabled (2) } TestStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents status of the test per subscriber line. Please refer to lineTestTable for details on how to start a test. Once test completes or aborted, status stays as pass, fail, or aborted respectively until user clears it by setting it to inactive or starts new test and that operation changes this to active." SYNTAX INTEGER { inactive (1), -- subscriber line is available for testing active (2), -- test is in progress on desired subscriber -- line pass (3), -- bit error rate is less than bit error limit fail (4), -- bit error rate is more than bit error limit aborted (5), -- user aborted the test waiting (6) -- waiting for the CPE to deliver the results of the -- test } TestType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents Types of tests support per line." SYNTAX INTEGER { none (0), -- No Test has been selected for this line lineQuality (1), -- CAP line quality test capHardware (2), -- CAP hardware test on the line card dmtLocalTest (3) -- DMT Local Test } -- -- C6200 System parameters -- -- -- System configuration allows user to change card type information. -- It is useful to create static system configuration which acts as -- inventory. This information is used by the system to monitor and -- and report any runtime configuration mismatch. -- systemType OBJECT-TYPE SYNTAX INTEGER { c62OC3 (1) -- system with OC3 based network interface } MAX-ACCESS read-only STATUS current DESCRIPTION "This type provides specific details about C6200 system type and what kind of network interface it uses." ::= { c62System 1 } systemAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "This reflects the alarm level of the C6200 system. It is the aggregation of the slot/port level alarms. Alarm levels supported at the system level are none, minor, major and critical. Unknown has no meaning." ::= { c62System 2 } systemAlarmLevelChngCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counter indicating a change in the system alarm level due to change either at the slot or port alarm level. This will be incremented by the system whenever any new alarm is raised or cleared at slot or port level. This is needed as rising or clearing of an alarm at port or slot level may not cause systemAlarmLevel to change. This counter, in such case helps manager application to recognize that alarm levels below system level has changed without causing change in the systemAlarmLevel. e.g. Say: System has two subscriber lines experiencing a minor alarm condition. systemAlarmLevel will be a minor alarm in such case. Now if one of the port level minor alarms clear, a port alarm level would become OK but the system and slot alarm levels may stay as a minor alarm." ::= { c62System 3 } systemReset OBJECT-TYPE SYNTAX CommandValue MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter allows user to reboot the system with system configuration from NVRAM (non-volatile memory). It can be used for following purposes: (1) Undo changes made to the system and not yet saved in the NVRAM. (2) Force the system to reboot from NVRAM configuration. This command disrupts service to all the subscribers associated with the system, so it should be use sparingly." ::= { c62System 4 } systemSaveCnfg OBJECT-TYPE SYNTAX CommandValue MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter allows user/operator to make system changes permanent. It causes system to write the system configuration on a non-volatile memory (NVRAM). There is no need to restart the system to make these changes effective." ::= { c62System 5 } systemProvChngCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counter indicating a card or subscriber provisioning change. This will be incremented by the system whenever any change is made. This is used to avoid unneccessary polling." ::= { c62System 6 } -- -- Environment Alarm Parameters -- -- -- Slot table defines the individual cards that make up the -- CISCO 6200 system. -- systemHClockAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "This reflects the alarm level of the H-bus backplane clock. H-bus clock error results in critical alarm at the at system level (systemAlarmLevel = critical)." ::= { c62System 7 } systemFanAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "This reflects the alarm level of the fans. Error for this parameter indicates failure of one or more fans. This error results in minor alarm at the system level (systemAlarmLevel = minor)." ::= { c62System 8 } systemTemperatureAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "This reflects the alarm level of the system temperature. When temperature exceeds system preconfigured system allowable limit this parameter indicates an error. This error results in minor alarm at the system level (systemAlarmLevel = minor)." ::= { c62System 9 } systemACO OBJECT-TYPE SYNTAX CommandValue MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter deactivates the audible alarm at the system. Audible alarm is generated by the system to announce detection of new alarm(s). Once deactivated, system may activate it again if it detects new additional alarm(s)." ::= { c62System 10 } slotTable OBJECT-TYPE SYNTAX SEQUENCE OF SlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table contains slot level information such as status, status change time, card type and software version. It is indexed using slot identifier. Empty entries are indicated using status empty and card type none. Operator can provision a new card in the system by setting slotCnfType parameter in this table. Changes to the slot configuration are temporary until user actually requests save operation through systemSaveCnfg. Only at that point system writes information in the NVRAM storage and information becomes permanent." ::= { c62Slot 1 } slotEntry OBJECT-TYPE SYNTAX SlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in the slot table" INDEX { slotID } ::= { slotTable 1 } SlotEntry ::= SEQUENCE { slotID INTEGER, slotType C6200CardType, slotStatus INTEGER, slotSwVersion Integer32, slotAlarmLevelChngCounter Counter32, slotCnfType C6200CardType, slotSubscriberChngCounter Counter32, slotAlarmLevel AlarmLevel } slotID OBJECT-TYPE SYNTAX INTEGER (1..14) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Slot Identifier for the selected slot." ::= { slotEntry 1 } slotType OBJECT-TYPE SYNTAX C6200CardType MAX-ACCESS read-only STATUS current DESCRIPTION "The current type of card in the physical cage, as reported by the system." ::= { slotEntry 2 } slotStatus OBJECT-TYPE SYNTAX INTEGER { empty (1), -- Slot is empty. notProvisioned (2), -- A card has been detected in the slot, -- but has not been provisioned. missing (3), -- Slot has been provisioned, but there is -- no card in the slot. mismatch (4), -- Slot has been provisioned, but the card -- in the slot is not the correct type. match (5) -- Slot has been provisioned and the card -- in the slot is the correct type. } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the slot." ::= { slotEntry 3 } slotSwVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The currently active firmware version number as a positive whole number, e.g. 100." ::= {slotEntry 4 } slotAlarmLevelChngCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counter indicating change in the port alarm level. This is needed as rising or clearing of an port level alarm may not cause slotAlarmLevel to change. This counter, in such case helps a manager application to recognize that the alarm levels below slot level have changed without change in the slotAlarmLevel (e.g. Say: a line card has two subscriber lines experiencing Minor alarm condition. The slot alarm level will be minor alarm in such case. Now if one of the port level minor alarms clear, the port alarm level would become OK but slot alarm level will stay as a minor alarm. Alarm level change includes rising or clearing of a new alarm at slot/port level)." ::= {slotEntry 5 } slotCnfType OBJECT-TYPE SYNTAX C6200CardType MAX-ACCESS read-write STATUS current DESCRIPTION "Card type, as provisioned by the operator used to compare against card type reported by the system for monitoring purposes. If slotType and slotCnfType do not match and slotCnfType is not set to none, slotStatus is set to mismatch. This condition only clears when operator corrects the configuration to make them match. The valid card type for each slot is as follows: slot 1: oc3si, oc3mm, stm1si and stm1mm slot 2: ctl slot 3 & 4: none slot 5 - 14: cap8 and dmt8" ::= { slotEntry 6 } slotSubscriberChngCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counter indicating change in the subscriber table. This will be incremented by the slot whenever any change is made at the port level. This is used to avoid unneccessary polling at the subscriber table level." ::= { slotEntry 7 } slotAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "This reflects the alarm level of the slot. It is the aggregation of the port level alarms. Alarm levels supported at the slot level are none, minor, major, critical and unknown." ::= { slotEntry 8 } -- -- Lets define portID which will be used to access OC3 port as well -- as subscriber line information -- portID OBJECT-TYPE SYNTAX Integer32(0..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Identifier on the targeted slot. PortID value depends on the slot type." ::= { c62Slot 2 } -- -- Optical Interface Fault Parameters -- oCInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF OCInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains SONET alarm information. It is indexed using slot and port identifier. Each object represents the alarm level of individual SONET alarm condition." ::= { c62OCInterface 1 } oCInterfaceEntry OBJECT-TYPE SYNTAX OCInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a SONET alarm condition. Following are the definition of SONET level alarms: EQF - Equipment Failure (Local) (causes slotStatus to be critical) Near End Alarms (causes slotStatus to be critical): LOS - Loss of Signal LOF - Loss of Frame LAIS - Line Alarm Indication Signal LOP - Loss of Pointer PAIS - Path Alarm Indication Signal SLM - Signal Label Mismatch Far End Alarms: (causes slotStatus to be critical) LRFI - Line Remote Failure Indication PRFI - Path Remote Failure Indication Miscellaneous. Alarms: LOST - Loss Of Synchronization (causes slotStatus to be major) LOCD - Loss 0f Cell Delineation. (causes slotStatus to be critical) Individual alarm description describes any interdependencies between alarm types. It also contains port status and interface mode." INDEX { slotID, portID } ::= { oCInterfaceTable 1 } OCInterfaceEntry ::= SEQUENCE { oCIAlarmLevel AlarmLevel, oCIEQF AlarmLevel, oCILOS AlarmLevel, oCILOF AlarmLevel, oCILAIS AlarmLevel, oCILOP AlarmLevel, oCIPAIS AlarmLevel, oCISLM AlarmLevel, oCILRFI AlarmLevel, oCIPRFI AlarmLevel, oCILOST AlarmLevel, oCILOCD AlarmLevel, oCILoopMode INTEGER } oCIAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "The current alarm level on the optical interface, may be none, major, critical or unknown. When the port is experiencing equipment failure or any of the near end alarm condition, the alarm level is marked critical. When the port is experiencing a far end alarm condition, the alarm level is marked major. When the port is in loopback mode, the alarm level is marked as unknown." ::= { oCInterfaceEntry 2 } oCIEQF OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Local equipment failure indication. Possible values are none or critical. When this attribute is critical, all other alarm conditions are unknown." ::= { oCInterfaceEntry 3 } -- -- Near End Alarms -- oCILOS OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of signal indication. Possible values are none or critical. When this attribute is critical, oCILOF, oCILOP, oCILAIS, oCIPAIS, oCISLM, oCILRFI, oCIPRFI and oCILOCD are unknown." ::= { oCInterfaceEntry 4 } oCILOF OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of frame indication. Possible values are none, critical or unknown. When this attribute is critical, oCILAIS, oCILOP, oCIPAIS, oCISLM, oCILRFI, oCIPRFI and oCILOCD are unknown." ::= { oCInterfaceEntry 5 } oCILAIS OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Line alarm indication signal. Possible values are none, critical or unknown. When this attribute is critical, oCILOP and oCISLM are unknown." ::= { oCInterfaceEntry 6 } oCILOP OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of pointer indication. Possible values are none, critical or unknown. When this attribute is critical, oCIPAIS, oCISLM and oCILOCD are unknown." ::= { oCInterfaceEntry 7 } oCIPAIS OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Path alarm indication signal. Possible values are none, critical or unknown. When this attribute is critical, oCISLM is unknown." ::= { oCInterfaceEntry 8 } oCISLM OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Signal label mismatch indication. Possible values are none, critical or unknown." ::= { oCInterfaceEntry 9 } -- -- Far End Alarms -- oCILRFI OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Line remote failure indication. Possible values are none, critical or unknown." ::= { oCInterfaceEntry 10 } oCIPRFI OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Path remote failure indication. Possible values are none, critical or unknown." ::= { oCInterfaceEntry 11 } -- -- Miscellaneous Alarms -- oCILOST OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of synchronization indication. Possible values are none, major or unknown." ::= { oCInterfaceEntry 12 } oCILOCD OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of cell delineation. Possible values are none, critical or unknown." ::= { oCInterfaceEntry 13 } oCILoopMode OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter puts the optical interface of C6200 system in facility (far end) loopback mode. It causes the node to loop all the traffic received on the optical interface back to the network. It does not generate any traffic or perform any kind of testing locally. This mode affects services to all the users connected through the node, so this facility must be used with care. User must set it back to disable mode once the testing completes. System will stay in loopback mode, if enabled, until the user disables the loop mode through NMS Manager or the system terminates - in which case loop mode is disabled automatically. It is only meaningful when the out of band management channel is used for management. It may not be useful when the in-band management channel is used for management traffic, as it causes breakdown in the management communications channel. The alarm level of the port is set to unknown while loopback mode is enabled." ::= { oCInterfaceEntry 14 } -- -- Optical Interface Performance Parameters -- oCPerfTable OBJECT-TYPE SYNTAX SEQUENCE OF OCPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains SONET Performance parameters." ::= { c62OCInterface 2 } oCPerfEntry OBJECT-TYPE SYNTAX OCPerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a SONET performance parameters for the targeted port." INDEX { slotID, portID } ::= { oCPerfTable 1 } OCPerfEntry ::= SEQUENCE { oCPTxCellCount Counter32, oCPRxCellCount Counter32, oCPHecErrCount Counter32 } oCPTxCellCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Count of number of non-idle ATM cells inserted into the transmit SONET payload since system start time. This is free running counter and rolls back to zero when the value exceeds 2^32." ::= { oCPerfEntry 1 } oCPRxCellCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Count of number of ATM cells received at SONET interface since system start time. Idle cells and cells with uncorrectable header errors are not included in the count. This is a free running counter which rolls back to zero when the value exceeds 2^32." ::= { oCPerfEntry 2 } oCPHecErrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of uncorrectable header errors since system start time. This is a free running counter which rolls back to zero when the value exceeds 2^32." ::= { oCPerfEntry 3 } -- -- Line Interface Parameters -- lineInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF LineInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The line table describes basic identification and runtime fault information on the individual subscriber line. A subscriber line consists of a port on the line card, Customer Premises Equipment (CPE) and a physical line connecting both. Fault monitoring is supported for both ends of the line. Subscriber line information consists of upstream (local port) information as well as downstream (Remote CPE) information. Downstream (ATU-C->ATU-R) information is reported by the individual port of the line card locally. Upstream (ATU-R->ATU-C) information is remote end (CPE) information which can be obtained via heartbeat messages generated by the CPE, other proprietary or standards based mechanisms. This information is proxied by the line card on the C6200 system. Entries in the table with non-assigned port have their mode disabled, so no service is available unless the port is configured and assigned to a subscriber." ::= { c62LineInterface 1 } lineInterfaceEntry OBJECT-TYPE SYNTAX LineInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry describes the fields being supported by the line table." INDEX { slotID, portID } ::= { lineInterfaceTable 1 } LineInterfaceEntry ::= SEQUENCE { lineAlarmLevel AlarmLevel, lineDwnSNRMargin Integer32, lineDwnLOCD AlarmLevel, lineDwnErrSecs Counter32, lineDwnLineRate Gauge32, lineUpSNRMargin Integer32, lineUpLOCD AlarmLevel, lineUpErrSecs Counter32, lineUpLineRate Gauge32, lineRateAlarm INTEGER, lineMode INTEGER, lineDMTDwnAttenuation Gauge32, lineDMTUpAttenuation Gauge32, lineDMTDwnLPR AlarmLevel, lineDMTUpLOS AlarmLevel, lineDMTUpLOF AlarmLevel, lineDMTLoopback INTEGER } lineAlarmLevel OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "The current alarm level of the port. Refer to TEXTUAL-CONVENTION section for details on AlarmLevel. Only following values for the AlarmLevel are possible for this attribute: none - Everything is fine minor - Local end or remote end is experiencing problems, e.g. (1) loss of Cell Delineation is observed on the downstream direction. (2) subscriberDwnLineRate and lineDwnLineRate do not match. (3) subscriberUpLineRate and lineUpLineRate do not match. (4) Both Up/down line rates do not match with the subscriber requested rates. (5) loss of signal is observed in the downstream direction for DMT cards and the object subscriberDMTLOSConfig is configured to alarm this condition. (6) loss of frame is observed in the downstream direction for DMT cards. unknown - Remote end is non-reachable. This could be either due to power down at the CPE or due to break in the connection between C6200 system and the CPE. This is exhibited by the lineDMTUpLOS alarm." ::= { lineInterfaceEntry 1 } -- -- ATU-C (Downstream) information -- lineDwnSNRMargin OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "In db, the difference between the current downstream signal to noise ratio and the SNR required for the selected line rate. as seen by the cpe. This object must be divided by 10 to obtain the real value for CAP only. Following are the possible values: Negative number - bad SNR margin for the desired line rate. 0 - adequate SNR (no margin) for the desired line rate. Positive number - Good SNR margin for the desired line rate. Higher number means better SNR margin and better line quality." ::= { lineInterfaceEntry 2 } lineDwnLOCD OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Downstream loss of cell delineation. It indicates that the cpe received cells on the line do not contain a valid header error check (HEC). This object is no longer supported." ::= { lineInterfaceEntry 3 } lineDwnErrSecs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream count of errored seconds received by the cpe. An error second is a second with line quality problems due to a HEC error in CAP cards or CRC, LOS or SEF events in DMT cards." ::= { lineInterfaceEntry 4 } lineDwnLineRate OBJECT-TYPE SYNTAX Gauge32 UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Current downstream line rate in kbps. It is adapted by the line card using rate adaptation logic." ::= { lineInterfaceEntry 5 } -- -- ATU-R (Upstream) information -- lineUpSNRMargin OBJECT-TYPE SYNTAX Integer32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "In db, the difference between the current upstream signal to noise ratio and the SNR required for the selected line rate as seen by the co. This object must be divided by 10 to obtain the real value for CAP only. Following are the possible values: Negative number - bad SNR margin for the desired line rate. 0 - adequate SNR (no margin) for the desired line rate. Positive number - Good SNR margin for the desired line rate. Higher number means better SNR margin and better line quality." ::= { lineInterfaceEntry 6 } lineUpLOCD OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream loss of cell delineation. It indicates that the co received cells on the line do not contain a valid header error check (HEC). This alarm will be marked unknown if lineDMTDwnLPR, lineDMTUpLOS or lineDMTUpLOF on a DMT card are minor." ::= { lineInterfaceEntry 7 } lineUpErrSecs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream count of errored seconds recieved by the co. An error second is a second with line quality problems due to a HEC error. or CRC, LOS or SEF events in DMT cards." ::= { lineInterfaceEntry 8 } lineUpLineRate OBJECT-TYPE SYNTAX Gauge32 UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Current upstream line rate in kbps. This is adapted by the line card using rate adaptation logic." ::= { lineInterfaceEntry 9 } lineRateAlarm OBJECT-TYPE SYNTAX INTEGER { ok (1), down (2), up (3), downAndUp (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is the comparison between actual (lineDwnLineRate/ lineUpLineRate) and the user requested line rates (subscriberDwnLineRate/subscriberUpLineRate). User requested rates are part of the subscriber section of the MIB. Following is the list of possible values: 1 - both the line rates match user requested rates. 2 - Downstream line rate does not match user requested rate. 3 - Upstream line rate does not match user requested rate. 4 - Both rates do not match user requested rates." ::= { lineInterfaceEntry 10 } lineMode OBJECT-TYPE SYNTAX INTEGER { testing (1), -- line is under test. training (2), -- line is trying to acquire user requested -- rate or in rate adaptation mode. active (3), -- line is active and in data transfer mode. down (4) -- subscriber line is administratively disabled. } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter shows current mode of the line. The possible modes are as shown above. Normally line stays in active mode, if everything is fine. If the line test fails, it goes into training mode and tries to acquire next possible lower rate. The line can also go into the training mode when the line card is unable to communicate to the remote end. It does not come out of the training mode until it is able to acquire a user requested rate or a lower rate, if that is unattainable. This mode is changed by the system to down, when the subscriber line is administratively disabled." ::= { lineInterfaceEntry 11 } lineDMTDwnAttenuation OBJECT-TYPE SYNTAX Gauge32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Measures downstream attenuation of the line reported by the CPE for the DMT card only. The units for this value are in decibels (dB). This object is instantiated for the CAP card." ::= { lineInterfaceEntry 12 } lineDMTUpAttenuation OBJECT-TYPE SYNTAX Gauge32 UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Measures upstream attenuation of the line reported by the CO for the DMT card only. The units for this value are in decibels (dB). This object is instantiated for the CAP card." ::= { lineInterfaceEntry 13 } lineDMTDwnLPR OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream loss of power indicator reported by the CPE for the DMT card only. Valid values are minor, unknown, or none. When this alarm is minor, lineUpLOS, lineUpLOF and lineUpLOCD are unknown. This object is instantiated for the CAP card." ::= { lineInterfaceEntry 14 } lineDMTUpLOS OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream loss of signal alarm indicator reported by the CO for the DMT card only. Valid values are minor or none. When this alarm is minor, lineDMTUpLOF and lineUpLOCD are unknown. This object is instantiated for the CAP card." ::= { lineInterfaceEntry 15 } lineDMTUpLOF OBJECT-TYPE SYNTAX AlarmLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream loss of frame alarm indicator reported by the CO for the DMT card only. Valid values are minor or none. When this alarm is minor, lineUpLOCD is unknown. This alarm value is unknown when lineDMTDwnLPR or lineDMTUpLOS is minor. This object is instantiated for the CAP card." ::= { lineInterfaceEntry 16 } lineDMTLoopback OBJECT-TYPE SYNTAX INTEGER { none (1), dslline (2), local (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DMT supported ATM layer loopback. dslline loops all ATM cells toward the CO modem back to the CPE. Local loops all ATM cells sent by the ATM trunk card toward the ATM trunk card. When this object is not set to none, lineMode will be set to testing. This object is instantiated for the CAP card." ::= { lineInterfaceEntry 17 } -- -- ATU-C (Line Interface) Performance Parameters -- linePerfTable OBJECT-TYPE SYNTAX SEQUENCE OF LinePerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains line performance parameters. It contains one entry per subscriber line. Only the ATU-C (local) performance parameters are reported in this table." ::= { c62LineInterface 2 } linePerfEntry OBJECT-TYPE SYNTAX LinePerfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a performance parameter for the targeted subscriber line." INDEX { slotID, portID } ::= { linePerfTable 1 } LinePerfEntry ::= SEQUENCE { lineTxCellCount Counter32, lineRxCellCount Counter32, lineHecErrCount Counter32, lineDMTDwnFECCount Counter32, lineDMTUpFECCount Counter32, lineDMTDwnCRCCount Counter32, lineDMTUpCRCCount Counter32, lineDMTDwnLOSCount Counter32, lineDMTUpLOSCount Counter32, lineDMTDwnSEFCount Counter32, lineDMTUpRDICount Counter32 } lineTxCellCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total cell count in the downstream direction (ATU-C->ATU-R) reported by the CPE. The counter value does not include cells with uncorrectable HEC errors. This is a free running counter which rolls back to zero when the value exceeds 2^32." ::= { linePerfEntry 1 } lineRxCellCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total cell count in the upstream direction (ATU-R->ATU-C) reported by the CO. The counter value does not include cells with uncorrectable HEC errors. This is a free running counter which rolls back to zero when the value exceeds 2^32." ::= { linePerfEntry 2 } lineHecErrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total HEC error count in the upstream (ATU-R->ATU-C) direction reported by the CO. This is a free running counter which rolls back to zero when the value exceeds 2^32." ::= { linePerfEntry 3 } lineDMTDwnFECCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream count of forward error correction (FEC) events reported by the CPE for the DMT card only." ::= { linePerfEntry 4 } lineDMTUpFECCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream count of forward error correction (FEC) events reported by the CO for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 5 } lineDMTDwnCRCCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream count of cyclical error correction (CRC) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 6 } lineDMTUpCRCCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream count of cyclical error correction (CRC) events reported by the CO for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 7 } lineDMTDwnLOSCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream count of loss of signal (LOS) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 8 } lineDMTUpLOSCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream count of loss of signal (LOS) events reported by the CO for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 9 } lineDMTDwnSEFCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Downstream count of severly errored frame (SEF) events reported by the CPE for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 10 } lineDMTUpRDICount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Upstream count of remote defect indication (RDI) events reported by the CO for the DMT card only. This object is instantiated for the CAP card." ::= { linePerfEntry 11 } -- -- Line Test Table -- lineTestTable OBJECT-TYPE SYNTAX SEQUENCE OF LineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Line test table contains the line test parameters per subscriber line. It controls access to the testing capabilities at the subscriber line level. This table contains an entry per subscriber line." ::= { c62LineInterface 3 } lineTestEntry OBJECT-TYPE SYNTAX LineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry describes the fields supported by the line test table." INDEX { slotID, portID } ::= { lineTestTable 1 } LineTestEntry ::= SEQUENCE { lineTestTrigger INTEGER, lineTestType TestType, lineTestTimeIntvl INTEGER, lineTestStatus TestStatus, lineTestDwnBitErrRate Integer32, lineTestUpBitErrRate Integer32, lineTestStartTime DateAndTime, lineTestCmplTime DateAndTime, lineTestBitErrRateLimit Integer32 } lineTestTrigger OBJECT-TYPE SYNTAX INTEGER { stop (1), start (2), clear (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Starts or stops (aborts) a test in progress. The agent will only start a new test, if no test is active on the targeted port. The user must set lineTestTimeIntvl to an appropriate value before starting test by setting this parameter to start. The System resets the value back to stop when the test completes. This parameter value affects lineTestStatus as following: value current lineTestStatus new lineTestStatus ----- ---------------------- ------------------ start inactive/pass/fail/ active aborted stop active aborted clear pass/fail/aborted inactive The rest of the combinations will result in error. Starting of the test may fail due to a line test already in progress on the selected subscriber line. Agent updates lineTestStartTime, when it accepts the line test. Agent updates lineTestCmplTime, when the test completes or when user aborts the test. Stopping a test resets lineTestUpBitErrRate and lineTestDwnBitErrRate. Clearing a test resets lineTestStartTime, lineTestCmplTime, lineTestUpBitErrRate, and lineTestDwnBitErrRate to zero. lineTestTimeIntvl and lineTestBitErrRateLimit get set back to their defaults. Finally, lineTestStatus is set to inactive. Line test information only resets when the user sets this parameter to clear, otherwise parameters from the previous run of the test are preserved until system is rebooted. All of the parameters are initialized on reboot." ::= { lineTestEntry 1 } lineTestType OBJECT-TYPE SYNTAX TestType MAX-ACCESS read-write STATUS current DESCRIPTION "The type of the test to be performed. If capHardware test is selected, time interval is determined by the system. Both the test types are destructive: affects the service on that line. The agent will only change lineTestType, if no test is active on the targeted port. For DMT cards, the DMTLocalTest is available. It is a destructive test that affects service on that line." ::= { lineTestEntry 2 } lineTestTimeIntvl OBJECT-TYPE SYNTAX INTEGER (0..60) UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval in minutes between 0 - 60 minutes. This parameter is only meaningful, if test type is the line quality test. Default value is 30 minutes. The agent will only change lineTestTimeIntvl, if no test is active on the targeted port." DEFVAL { 30 } ::= { lineTestEntry 3 } lineTestStatus OBJECT-TYPE SYNTAX TestStatus MAX-ACCESS read-only STATUS current DESCRIPTION "System changes values for this variable based on trigger value as well as based on system reported result. When test completes, system compares lineTestDwnBitErrRate and lineTestUpBitErrRate to lineTestBitErrRateLimit in order to determine whether the line test failed or passed. Agent sets this variable based on this comparison." ::= { lineTestEntry 4 } lineTestDwnBitErrRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is positive integer value representing a negative exponent of 10 for the error rate in the downstream direction. It is only meaningful when the line quality test is done on the affected subscriber line. It is compared against lineTestBitErrRateLimit to determine lineTestStatus value when the line quality test completes. This value is interpreted as following: < 10-7 - Bad line quality 10-7 - Acceptable line quality > 10-7 - Better line quality" ::= { lineTestEntry 5 } lineTestUpBitErrRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is positive integer value representing a negative exponent of 10 for the error rate in the upstream direction. It is only meaningful when the line quality test is done on the affected subscriber line. It is compared against lineTestBitErrRateLimit to determine lineTestStatus value when the line quality test completes. This value is interpreted as following: < 10-7 - Bad line quality 10-7 - Acceptable line quality > 10-7 - Better line quality" ::= { lineTestEntry 6 } lineTestStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Time stamp in displayable format. This is the time when the system starts the requested test." ::= { lineTestEntry 7 } lineTestCmplTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Time stamp in displayable format. This is the time when the system completes the requested test or when the user aborts the test." ::= { lineTestEntry 8 } lineTestBitErrRateLimit OBJECT-TYPE SYNTAX Integer32(3..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a positive integer representing a negative exponent of 10. It represents bit error rate limit allowed for the subscriber line quality test. The system compares the bit error rates reported at the end of line quality test to this limit to determine line quality. Allowable error rates are between 10-3 and 10-10. The agent will only change lineTestBitErrRateLimit, if no test is active on the targeted port." ::= { lineTestEntry 9 } -- -- Subscriber Provisioning Parameters -- subscriberTable OBJECT-TYPE SYNTAX SEQUENCE OF SubscriberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The subscriber table contains configuration information per subscriber line. Non-assigned entries are identified by NULL string for the subscriber name. It contains provisionable information such as subscriber name, line rate and subscriber line state.. The subscriber provisioning request may fail, if the targeted subscriber line is under test. Changes to the subscriber information are temporary until user actually requests save operation through systemSaveCnfg. Only at that point system writes information in the NVRAM storage and information becomes permanent." ::= { c62Subscriber 1 } subscriberEntry OBJECT-TYPE SYNTAX SubscriberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry describes the fields being supported by the subscriber table." INDEX { slotID, portID } ::= { subscriberTable 1 } SubscriberEntry ::= SEQUENCE { subscriberName DisplayString, subscriberUpLineRate Integer32, subscriberDwnLineRate Integer32, subscriberLineState InterfaceStatus, subscriberDMTLOSConfig InterfaceStatus } subscriberName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) MAX-ACCESS read-write STATUS current DESCRIPTION "The subscriber Id, free format string field. First character can not be a space. Set this field to NULL string to delete a subscriber entry from the database. The delete operation will also disable the affected subscriber line. The system resets all the subscriber information such as subscriberUpLineRate, subscriberDwnLineRate, and subscriberLineState to default values on the delete or for non assigned entries." DEFVAL { "DSL<slotID>/<portID>" } ::= { subscriberEntry 1 } subscriberUpLineRate OBJECT-TYPE SYNTAX Integer32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "Desired maximum line rate. Actual rate may be lower following training sequence to acquire that rate. Refer to system features document for valid range. When this value is set to -1, system automatically adapts to maximum available rate. Following are the possible rates in kbps the CAP card: 1088, 952, 816, 680, 544, 408, 272 and 91. For the DMT card, the rates range from 64 Kbps to 1024 Kbps in increments of 32 Kbps." ::= { subscriberEntry 2 } subscriberDwnLineRate OBJECT-TYPE SYNTAX Integer32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "Desired maximum line rate. Actual rate may be lower following training sequence to acquire that rate. Refer to system features document for valid range. When this value is set to -1, system automatically adapts to maximum possible rate. Following are the possible rates in kbps for the CAP card: 7168, 6272, 4480, 2688, 2560, 2240, 1920, 1600, 1280, 960 and 640. For the DMT card, the rates range from 64 Kbps to 8168 Kbps in increments of 32 Kbps." ::= { subscriberEntry 3 } subscriberLineState OBJECT-TYPE SYNTAX InterfaceStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter reflects current state of the subscriber line. It allows targeted subscriber line to be enabled or disabled. Disabling the line cuts off services to the affected subscriber. All the empty lines are disabled by the system. User deletion, by setting subscriberName to NULL, also results in disabling of the line." DEFVAL { disabled } ::= { subscriberEntry 4 } subscriberDMTLOSConfig OBJECT-TYPE SYNTAX InterfaceStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This value determines whether or not the LOS condition on the subscriber line generates a minor alarm. By default, this value is set to disabled which means that an alarm is not generated when LOS is detected on the subscriber line." DEFVAL { disabled } ::= { subscriberEntry 5 } -- Conformance ciscoC6200MIBConformance OBJECT IDENTIFIER ::= { cisco6200MIB 2 } ciscoC6200MIBCompliances OBJECT IDENTIFIER ::= { ciscoC6200MIBConformance 1 } ciscoC6200MIBGroups OBJECT IDENTIFIER ::= { ciscoC6200MIBConformance 2 } -- Compliance ciscoC6200MIBCompliance MODULE-COMPLIANCE STATUS obsolete -- superceded by ciscoC6200MIBCompliance2 DESCRIPTION "The compliance statement for entities which implement the Cisco C6200 MIB. This device-specific MIB will be implemented only by members of the C6200 product line." MODULE -- this module MANDATORY-GROUPS { ciscoC6200SystemGroup, ciscoC6200SlotGroup, ciscoC6200oCIGroup, ciscoC6200oCIPerfGroup, ciscoC6200lineGroup, ciscoC6200lineTestGroup, ciscoC6200linePerfGroup, ciscoC6200subscriberGroup } ::= { ciscoC6200MIBCompliances 1 } ciscoC6200MIBCompliance2 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Cisco C6200 MIB. This device-specific MIB will be implemented only by members of the C6200 product line. This compliance takes effect from IOS Release 11.3(1)DA3." MODULE -- this module MANDATORY-GROUPS { ciscoC6200SystemGroup2, ciscoC6200SlotGroup2, ciscoC6200oCIGroup2, ciscoC6200oCIPerfGroup2, ciscoC6200lineGroup2, ciscoC6200lineTestGroup2, ciscoC6200linePerfGroup2, ciscoC6200subscriberGroup2 } ::= { ciscoC6200MIBCompliances 2 } -- Units of Conformance ciscoC6200SystemGroup OBJECT-GROUP OBJECTS { systemType, systemAlarmLevel, systemAlarmLevelChngCounter, systemReset, systemSaveCnfg, systemProvChngCounter, systemHClockAlarmLevel, systemFanAlarmLevel, systemTemperatureAlarmLevel, systemACO } STATUS obsolete -- superceded by ciscoC6200SystemGroup2 DESCRIPTION "System-level information for a C6200 device." ::= { ciscoC6200MIBGroups 1 } ciscoC6200SlotGroup OBJECT-GROUP OBJECTS { slotType, slotStatus, slotSwVersion, slotAlarmLevelChngCounter, slotCnfType, slotSubscriberChngCounter, slotAlarmLevel } STATUS obsolete -- superceded by ciscoC6200SlotGroup2 DESCRIPTION "Slot-level information for a C6200 device." ::= { ciscoC6200MIBGroups 2 } ciscoC6200oCIGroup OBJECT-GROUP OBJECTS { oCIAlarmLevel, oCIEQF, oCILOS, oCILOF, oCILAIS, oCILOP, oCIPAIS, oCISLM, oCILRFI, oCIPRFI, oCILOST, oCILOCD, oCILoopMode } STATUS obsolete -- superceded by ciscoC6200oCIGroup2 DESCRIPTION "NTC information for a C6200 device." ::= { ciscoC6200MIBGroups 3 } ciscoC6200oCIPerfGroup OBJECT-GROUP OBJECTS { oCPTxCellCount, oCPRxCellCount, oCPHecErrCount } STATUS obsolete -- superceded by ciscoC6200oCIPerfGroup2 DESCRIPTION "NTC performance information for a C6200 device." ::= { ciscoC6200MIBGroups 4 } ciscoC6200lineGroup OBJECT-GROUP OBJECTS { lineAlarmLevel, lineDwnSNRMargin, lineDwnLOCD, lineDwnErrSecs, lineDwnLineRate, lineUpSNRMargin, lineUpLOCD, lineUpErrSecs, lineUpLineRate, lineRateAlarm, lineMode } STATUS obsolete -- superceded by ciscoC6200lineGroup2 DESCRIPTION "Line-level information for a C6200 device." ::= { ciscoC6200MIBGroups 5 } ciscoC6200linePerfGroup OBJECT-GROUP OBJECTS { lineTxCellCount, lineRxCellCount, lineHecErrCount } STATUS obsolete -- superceded by ciscoC6200linePerfGroup2 DESCRIPTION "Line-level performance information for a C6200 device." ::= { ciscoC6200MIBGroups 6 } ciscoC6200lineTestGroup OBJECT-GROUP OBJECTS { lineTestTrigger, lineTestType, lineTestTimeIntvl, lineTestStatus, lineTestDwnBitErrRate, lineTestUpBitErrRate, lineTestStartTime, lineTestCmplTime, lineTestBitErrRateLimit } STATUS obsolete -- superceded by ciscoC6200lineTestGroup2 DESCRIPTION "Line-level test information for a C6200 device." ::= { ciscoC6200MIBGroups 7 } ciscoC6200subscriberGroup OBJECT-GROUP OBJECTS { subscriberName, subscriberUpLineRate, subscriberDwnLineRate, subscriberLineState } STATUS obsolete -- superceded by ciscoC6200subscriberGroup2 DESCRIPTION "Subscriber-level information for a C6200 device." ::= { ciscoC6200MIBGroups 8 } ciscoC6200SystemGroup2 OBJECT-GROUP OBJECTS { systemType, systemAlarmLevel, systemAlarmLevelChngCounter, systemReset, systemSaveCnfg, systemProvChngCounter, systemHClockAlarmLevel, systemFanAlarmLevel, systemTemperatureAlarmLevel, systemACO } STATUS current DESCRIPTION "System-level information for a C6200 device." ::= { ciscoC6200MIBGroups 9 } ciscoC6200SlotGroup2 OBJECT-GROUP OBJECTS { slotType, slotStatus, slotSwVersion, slotAlarmLevelChngCounter, slotCnfType, slotSubscriberChngCounter, slotAlarmLevel } STATUS current DESCRIPTION "Slot-level information for a C6200 device." ::= { ciscoC6200MIBGroups 10 } ciscoC6200oCIGroup2 OBJECT-GROUP OBJECTS { oCIAlarmLevel, oCIEQF, oCILOS, oCILOF, oCILAIS, oCILOP, oCIPAIS, oCISLM, oCILRFI, oCIPRFI, oCILOST, oCILOCD, oCILoopMode } STATUS current DESCRIPTION "NTC information for a C6200 device." ::= { ciscoC6200MIBGroups 11 } ciscoC6200oCIPerfGroup2 OBJECT-GROUP OBJECTS { oCPTxCellCount, oCPRxCellCount, oCPHecErrCount } STATUS current DESCRIPTION "NTC performance information for a C6200 device." ::= { ciscoC6200MIBGroups 12 } ciscoC6200lineGroup2 OBJECT-GROUP OBJECTS { lineAlarmLevel, lineDwnSNRMargin, lineDwnErrSecs, lineDwnLineRate, lineUpSNRMargin, lineUpLOCD, lineUpErrSecs, lineUpLineRate, lineRateAlarm, lineMode, lineDMTDwnAttenuation, lineDMTUpAttenuation, lineDMTDwnLPR, lineDMTUpLOS, lineDMTUpLOF, lineDMTLoopback } STATUS current DESCRIPTION "Line-level information for a C6200 device." ::= { ciscoC6200MIBGroups 13 } ciscoC6200linePerfGroup2 OBJECT-GROUP OBJECTS { lineTxCellCount, lineRxCellCount, lineHecErrCount, lineDMTDwnFECCount, lineDMTUpFECCount, lineDMTDwnCRCCount, lineDMTUpCRCCount, lineDMTDwnLOSCount, lineDMTUpLOSCount, lineDMTDwnSEFCount, lineDMTUpRDICount } STATUS current DESCRIPTION "Line-level performance information for a C6200 device." ::= { ciscoC6200MIBGroups 14 } ciscoC6200lineTestGroup2 OBJECT-GROUP OBJECTS { lineTestTrigger, lineTestType, lineTestTimeIntvl, lineTestStatus, lineTestDwnBitErrRate, lineTestUpBitErrRate, lineTestStartTime, lineTestCmplTime, lineTestBitErrRateLimit } STATUS current DESCRIPTION "Line-level test information for a C6200 device." ::= { ciscoC6200MIBGroups 15 } ciscoC6200subscriberGroup2 OBJECT-GROUP OBJECTS { subscriberName, subscriberUpLineRate, subscriberDwnLineRate, subscriberLineState, subscriberDMTLOSConfig } STATUS current DESCRIPTION "Subscriber-level information for a C6200 device." ::= { ciscoC6200MIBGroups 16 } END