CISCO-ACCESS-ENVMON-MIB.mib object view, vendor Cisco
Introduction
Most network devices and programs ship with so-called MIB files to describe the parameters and meanings (i.e.: friendly names) which are available for monitoring via SNMP.
ActiveXperts Network Monitor 2024 can import vendor-specific MIB files, so it can be used to monitor specific OID's (Object Identifiers).
This way, you can monitor your devices, computers, etc. by selecting your relevant OID's by name.
ActiveXperts Network Monitor 2024 can import MIB file CISCO-ACCESS-ENVMON-MIB and use it to monitor vendor specific OID's.
CISCO-ACCESS-ENVMON-MIB file content
Object view of CISCO-ACCESS-ENVMON-MIB:
Scalar Object |
caemSupplyStatusEntry |
.1.3.6.1.4.1.9.9.61.1.1.1 |
Additional information about the failure component or location
in the power Supply beyond that provided by Cisco Environmental
Monitor MIB's ciscoEnvMonSupplyStatusEntry.
|
Tabular Object |
caemSupplyFailedComponent |
.1.3.6.1.4.1.9.9.61.1.1.1.1 |
The failure component of the power supply being instrumented.
none - No failure.
inputVoltage - Input power lost in one of the power supplies
dcOutputVoltage - DC output voltage lost in one of the power supplies
thermal - Power supply thermal failure.
multiple - Multiple failures.
fan - Fan failure
overvoltage - Over voltage.
|
Table |
caemSupplyStatusTable |
.1.3.6.1.4.1.9.9.61.1.1 |
The table contains the additional power supply information
that are not covered in the ciscoEnvMonSupplyStatusTable of
CISCO-ENVMON-MIB.
|
Trap |
caemTemperatureNotification |
.1.3.6.1.4.1.9.9.61.2.0.1 |
A caemTemperatureNotification is sent if the over temperature
condition is detected in the managed system.
This is a replacement for the ciscoEnvMonTemperatureNotification
trap because the information 'ciscoEnvMonTemperatureStatusValue'
required by the trap is not available in the managed system.
|
caemVoltageNotification |
.1.3.6.1.4.1.9.9.61.2.0.2 |
A caemVoltageNotification is sent if the over voltage
condition is detected and ciscoEnvMonVoltageState is not set
to 'notPresent' in the managed system.
This is a replacement for the ciscoEnvMonVoltageNotification
trap because the information 'ciscoEnvMonVoltageStatusValue'
required by the trap is not available in the managed system.
|
Object Identifier |
ciscoAccessEnvMonMIB |
.1.3.6.1.4.1.9.9.61 |
The MIB module to describe the additional status of
the Environmental Monitor on those Cisco Access devices
which support one.
|
caemObjects |
.1.3.6.1.4.1.9.9.61.1 |
caemMIBNotificationPrefix |
.1.3.6.1.4.1.9.9.61.2 |
caemMIBNotifications |
.1.3.6.1.4.1.9.9.61.2.0 |
caemConformance |
.1.3.6.1.4.1.9.9.61.3 |
caemCompliances |
.1.3.6.1.4.1.9.9.61.3.1 |
caemGroups |
.1.3.6.1.4.1.9.9.61.3.2 |
Group |
caemGroup |
.1.3.6.1.4.1.9.9.61.3.2.1 |
A collection of objects providing the additional Environmental
Monitor information beyond that provided by
Cisco Environmental Monitor MIB.
|