AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-ATM-IF-PHYS-MIB

CISCO-ATM-IF-PHYS-MIB device MIB details by Cisco

CISCO-ATM-IF-PHYS-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-ATM-IF-PHYS-MIB.


Vendor: Cisco
Mib: CISCO-ATM-IF-PHYS-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- Subset of SONET and DS3/E3 and DS1/E1 MIBs for Rhino project
--
-- December 1995, C. Yadavalli
--
-- Copyright (c) 1996-1997 by cisco Systems, Inc.
-- All rights reserved.
-- --------------------------------------------------------------------
--
CISCO-ATM-IF-PHYS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    Counter32,
    OBJECT-TYPE                      FROM SNMPv2-SMI
    ifIndex                          FROM RFC1213-MIB
    ciscoMgmt                        FROM CISCO-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP  FROM SNMPv2-CONF;


ciscoAtmIfPhysMIB MODULE-IDENTITY
    LAST-UPDATED    "9609190000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "       Cisco Systems
                    Customer Service

            Postal: 170 W Tasman Drive
                    San Jose, CA  95134
                    USA

               Tel: +1 800 553-NETS

            E-mail: cs-atm@cisco.com"
    DESCRIPTION
            "A minimal set of managed objects for tracking
            the status of DS3/E3/DS1/E1 and SONET interfaces."
    REVISION        "9609190000Z"
    DESCRIPTION
            "Added DS1/E1 stuff."
    REVISION        "9608080000Z"
    DESCRIPTION
            "Added network clock source configuration and
             other physical layer configuration."
    REVISION        "9512020000Z"
    DESCRIPTION
            "Initial version of this MIB module."
    ::= { ciscoMgmt 45 }

ciscoAtmIfPhysMIBObjects OBJECT IDENTIFIER ::= { ciscoAtmIfPhysMIB 1 }

ciscoAtmIfPhysTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF CiscoAtmIfPhysEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
            "A table containing basic status and statistics for
            the physical layer of ATM interfaces."
    ::= { ciscoAtmIfPhysMIBObjects 1 }

ciscoAtmIfPhysEntry OBJECT-TYPE
    SYNTAX     CiscoAtmIfPhysEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
            "Basic status and statistics for the physical layer of
            an ATM interface."
    INDEX { ifIndex }
    ::= { ciscoAtmIfPhysTable 1 }

CiscoAtmIfPhysEntry ::=
    SEQUENCE {
            ciscoAtmIfPhysStatus               INTEGER,
            ciscoAtmIfPhysSectionParityErrors  Counter32,
            ciscoAtmIfPhysLineParityErrors     Counter32,
            ciscoAtmIfPhysPathParityErrors     Counter32,
            ciscoAtmIfPhysLcvErrors            Counter32,
            ciscoAtmIfPhysCBitParityErrors     Counter32,
            ciscoAtmIfPhysPBitParityErrors     Counter32,
            ciscoAtmIfPhysPlcpBipViolations    Counter32,
            ciscoAtmIfPhysLineFebeErrors       Counter32,
            ciscoAtmIfPhysPathFebeErrors       Counter32,
            ciscoAtmIfPhysCellPayloadScrambling INTEGER,
            ciscoAtmIfPhysStsStreamScrambling  INTEGER,
            ciscoAtmIfPhysFramingMode          INTEGER,
            ciscoAtmIfPhysLoopbackConfig       INTEGER,
            ciscoAtmIfPhysLineBuildOut         INTEGER,
            ciscoAtmIfPhysTransmitClockSource  INTEGER,
            ciscoAtmIfPhysClockSourcePriority  INTEGER,
            ciscoAtmIfPhysClockSourceStatus    INTEGER,
            ciscoAtmIfPhysDS1BitErrors         Counter32,
            ciscoAtmIfPhysE1CrcErrors          Counter32,
            ciscoAtmIfPhysLineCode             INTEGER
    }

ciscoAtmIfPhysStatus OBJECT-TYPE
    SYNTAX        INTEGER {
                      normal(1),
                      los(2),
                      lof(3),
                      loc(4),
                      ais(5),
                      yellowLine(6),
                      yellowPath(7),
                      lop(8),
                      idle(9),
                      yellowAlarm(10),
                      plcpLOF(11),
                      plcpYellow(12),
                      maFERF(13),
                      pathAis(14),
                      ocd(15)
                  }
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The status of the physical interface.  The value of this
              object is only valid when the interface's ifAdminStatus
              has the value 'up'.  Note that some of the enumerated
              values are specific to a particular physical layer."
    ::= { ciscoAtmIfPhysEntry 1 }

ciscoAtmIfPhysSectionParityErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of B1 (BIP) errors on the physical interface.
              This object is only present for SONET interfaces."
    ::= { ciscoAtmIfPhysEntry 2 }

ciscoAtmIfPhysLineParityErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of B2 (BIP) errors on the physical interface.
              This object is only present for SONET interfaces."
    ::= { ciscoAtmIfPhysEntry 3 }

ciscoAtmIfPhysPathParityErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of B3 (BIP) errors on the physical interface.
              This object is only present for SONET interfaces."
    ::= { ciscoAtmIfPhysEntry 4 }

ciscoAtmIfPhysLcvErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of Line Code Violation errors on the physical
              interface. This object is only present for DS3/E3/DS1/E1
              interfaces."
    ::= { ciscoAtmIfPhysEntry 5 }

ciscoAtmIfPhysCBitParityErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of C-bit parity violations on the physical
              interface.  This object is only present for DS3
              interfaces."
    ::= { ciscoAtmIfPhysEntry 6 }

ciscoAtmIfPhysPBitParityErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of P-bit parity violations or E3 G.832 BIP-8
               errors on the physical
              interface.  This object is present only for DS3/E3
              interfaces."
    ::= { ciscoAtmIfPhysEntry 7 }

ciscoAtmIfPhysPlcpBipViolations OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of PLCP BIP violations on the physical
              interface.  This object is only present for DS3/E3/DS1/E1
              interfaces."
    ::= { ciscoAtmIfPhysEntry 8 }

ciscoAtmIfPhysLineFebeErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of Z2 (Line FEBE) errors on the physical interface.
              This object is only present for SONET interfaces."
    ::= { ciscoAtmIfPhysEntry 9 }

ciscoAtmIfPhysPathFebeErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of G1 (Path FEBE) errors on the physical interface.
              This object is only present for SONET interfaces."
    ::= { ciscoAtmIfPhysEntry 10 }

ciscoAtmIfPhysCellPayloadScrambling OBJECT-TYPE
    SYNTAX        INTEGER { off(1),
                            on(2) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The status of whether cell payload scrambling is
              enabled or disabled on the physical interface."
    ::= { ciscoAtmIfPhysEntry 11 }

ciscoAtmIfPhysStsStreamScrambling OBJECT-TYPE
    SYNTAX        INTEGER { off(1),
                            on(2) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The status of whether STS-stream scrambling is
              enabled or disabled on the physical interface."
    ::= { ciscoAtmIfPhysEntry 12 }

ciscoAtmIfPhysFramingMode OBJECT-TYPE
    SYNTAX        INTEGER { sonet(1),
                            sdh(2),
                            ds3m23adm(3),
                            ds3m23plcp(4),
                            ds3cbitadm(5),
                            ds3cbitplcp(6),
                            e3g832adm(7), 
                            e3g751adm(8), 
                            e3g751plcp(9),
                            ds1sfadm(10),
                            ds1esfadm(11),
                            ds1sfplcp(12),
                            ds1esfplcp(13),
                            e1adm(14),
                            e1plcp(15),
                            e1crcadm(16),
                            e1crcplcp(17)}
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The framing format present on the physical interface.

               'sonet' indicates sts-3c or sts-12c format and applies only
              to OC-3 and OC-12 type interfaces, respectively.

               'sdh' indicates stm1 or stm4 format and applies only to
              OC-3 and OC-12 type interfaces, respectively.
 
               'ds3m23adm' indicates M23 ADM mode and applies only to DS3
              type interfaces.

               'ds3m23plcp' indicates M23 PLCP mode and applies only to DS3
              type interfaces.

               'ds3cbitadm' indicates C-BIT ADM mode and applies only to DS3
              type interfaces.

               'ds3cbitplcp' indicates C-BIT PLCP mode and applies only to DS3
              type interfaces.

               'e3g832adm' indicates G.832 ADM mode and applies only to E3
              type interfaces.

               'e3g751adm' indicates G.751 ADM mode and applies only to E3
              type interfaces.

               'e3g751plcp' indicates G.751 PLCP mode and applies only to E3
              type interfaces.

               'ds1sfadm' indicates DS1 SF ADM mode and applies only to DS1
              type interfaces.

               'ds1esfadm' indicates DS1 ESF ADM mode and applies only to DS1
              type interfaces.

               'ds1sfplcp' indicates DS1 SF PLCP mode and applies only to DS1
              type interfaces.

               'ds1esfplcp' indicates DS1 ESF PLCP mode and applies only to DS1
              type interfaces.

               'e1adm' indicates E1 ADM mode and applies only to E1
              type interfaces.

               'e1plcp' indicates E1 PLCP mode and applies only to E1
              type interfaces.

               'e1crcadm' indicates E1 CRC-4 ADM mode and applies only to E1
              type interfaces.

               'e1crcplcp' indicates E1 CRC-4 PLCP mode and applies only to E1
              type interfaces."
    ::= { ciscoAtmIfPhysEntry 13 }

ciscoAtmIfPhysLoopbackConfig OBJECT-TYPE
    SYNTAX        INTEGER { noLoop(1),
                            diagnosticLoop(2),
                            lineLoop(3),
                            otherLoop(4) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The loopback configured on the physical interface:

               'noLoop' indicates no loopback is present.

               'diagnosticLoop' indicates transmit data stream is
              looped to the receive direction.

               'lineLoop' indicates receive data stream is
              looped to the transmit direction.

               'otherLoop' indicates loopbacks that are not defined here.  "
    ::= { ciscoAtmIfPhysEntry 14 }

ciscoAtmIfPhysLineBuildOut OBJECT-TYPE
    SYNTAX        INTEGER { e3AllCables(1),
                            ds3CablesUnder225(2),
                            ds3CablesOver225(3),
                            ds1Cables0To110(4),
                            ds1Cables110To220(5),
                            ds1Cables220To330(6),
                            ds1Cables330To440(7),
                            ds1Cables440To550(8),
                            ds1Cables550To660(9),
                            ds1CablesOver600(10),
                            e1AllCables(11) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The line buildout configured on the transmit signal:

               'e3AllCables' applies to all cables of E3 physical
              interfaces.

               'ds3CablesUnder225' applies to cables under 225 feet of
              DS3 physical interfaces.

               'ds3CablesOver225' applies to cables over 225 feet of
              DS3 physical interfaces.

               'ds1Cables0To110' applies to cables 0 to 110 feet of
              DS1 physical interfaces.

               'ds1Cables110To220' applies to cables 110 to 220 feet of
              DS1 physical interfaces.

               'ds1Cables220To330' applies to cables 220 to 330 feet of
              DS1 physical interfaces.

               'ds1Cables330To440' applies to cables 330 to 440 feet of
              DS1 physical interfaces.

               'ds1Cables440To550' applies to cables 440 to 550 feet of
              DS1 physical interfaces.

               'ds1Cables550To660' applies to cables 550 to 660 feet of
              DS1 physical interfaces.

               'ds1CablesOver600' applies to cables over 600 feet of
              DS1 physical interfaces.

               'e1AllCables' applies to all cables of
              E1 physical interfaces.  "
    ::= { ciscoAtmIfPhysEntry 15 }

ciscoAtmIfPhysTransmitClockSource OBJECT-TYPE
    SYNTAX        INTEGER { loopTiming(1),
                            freeRunning(2),
                            networkDerived(3) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The source of the tranmit clock:

               'loopTiming' indicates that the recovered receive
              clock is used as the transmit clock.

               'freeRunning' indicates that a local clock source is
              used.

               'networkDerived' indicates that recovered receive
              clock from another interface is used as the transmit
              clock source.  "
    ::= { ciscoAtmIfPhysEntry 16 }

ciscoAtmIfPhysClockSourcePriority OBJECT-TYPE
    SYNTAX        INTEGER { notConfigured(1),
                            priority1(2),
                            priority2(3),
                            priority3(4),
                            priority4(5) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The priority of this interface if configured as
              a network clock source.

               'notConfigured' indicates this is not configured as
              a network clock source.  "
    ::= { ciscoAtmIfPhysEntry 17 }

ciscoAtmIfPhysClockSourceStatus OBJECT-TYPE
    SYNTAX        INTEGER { notSelected(1),
                            selected(2) }
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The network clock source status of this interface:

               'notSelected' indicates this is not selected as the
              network clock source.

               'selected' indicates this is selected as the
              network clock source.  "
    ::= { ciscoAtmIfPhysEntry 18 }

ciscoAtmIfPhysDS1BitErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of bit errors (CRC-6 error in ESF mode and
               framing bit error in SF mode) on the physical
              interface.  This object is only present for DS1
              interfaces."
    ::= { ciscoAtmIfPhysEntry 19 }

ciscoAtmIfPhysE1CrcErrors OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
              "The number of CRC errors (in CRC-4 mode) on the physical
              interface.  This object is only present for E1
              interfaces."
    ::= { ciscoAtmIfPhysEntry 20 }

ciscoAtmIfPhysLineCode OBJECT-TYPE
    SYNTAX        INTEGER { ami(1),
                            b8zs(2),
                            hdb3(3) }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
              "The line coding present on the physical interface  This object
              is only present for DS1/E1 interfaces.

               'ami' indicates alternate mark inversion (AMI) line code
              on the DS1/E1 interface.

               'b8zs' indicates B8ZS line code on the physical interface and
              applies only to DS1 interfaces.
 
               'hdb3' indicates HDB3 line code on the physical interface and
              applies only to E1 interfaces. "

    ::= { ciscoAtmIfPhysEntry 21 }

-- conformance information

ciscoAtmIfPhysMIBConformance
               OBJECT IDENTIFIER ::= { ciscoAtmIfPhysMIB 3 }
ciscoAtmIfPhysMIBCompliances 
               OBJECT IDENTIFIER ::= { ciscoAtmIfPhysMIBConformance 1 }
ciscoAtmIfPhysMIBGroups
               OBJECT IDENTIFIER ::= { ciscoAtmIfPhysMIBConformance 2 }


-- compliance statements

ciscoAtmIfPhysMIBCompliance MODULE-COMPLIANCE
    STATUS  obsolete -- susperseded by ciscoAtmIfPhysMIBCompliance2
    DESCRIPTION
            "The compliance statement for entities which implement
            the Cisco ATM Interface Physical MIB."
    MODULE  -- this module
            MANDATORY-GROUPS { ciscoAtmIfPhysMIBCommonGroup }
    ::= { ciscoAtmIfPhysMIBCompliances 1 }


ciscoAtmIfPhysMIBCompliance2 MODULE-COMPLIANCE
    STATUS  obsolete -- susperseded by ciscoAtmIfPhysMIBCompliance3
    DESCRIPTION
            "The compliance statement for entities which implement
            the Cisco ATM Interface Physical MIB."
    MODULE  -- this module
            MANDATORY-GROUPS { ciscoAtmIfPhysMIBCommonGroup,
                               ciscoAtmIfPhysMIBCommonGroup2
                             }

           GROUP       ciscoAtmIfPhysMIBSonetGroup
           DESCRIPTION
               "This group is required for all SONET interfaces."

           GROUP       ciscoAtmIfPhysMIBSonetGroup2
           DESCRIPTION
               "This group is required for all SONET interfaces."

           GROUP       ciscoAtmIfPhysMIBDs3E3Group
           DESCRIPTION
               "This group is required for all DS3/E3 interfaces."

           GROUP       ciscoAtmIfPhysMIBDs3Group
           DESCRIPTION
               "This group is required for all DS3 interfaces."

    ::= { ciscoAtmIfPhysMIBCompliances 2 }

ciscoAtmIfPhysMIBCompliance3 MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for entities which implement
            the Cisco ATM Interface Physical MIB."
    MODULE  -- this module
            MANDATORY-GROUPS { ciscoAtmIfPhysMIBCommonGroup,
                               ciscoAtmIfPhysMIBCommonGroup2
                             }

           GROUP       ciscoAtmIfPhysMIBSonetGroup
           DESCRIPTION
               "This group is required for all SONET interfaces."

           GROUP       ciscoAtmIfPhysMIBSonetGroup2
           DESCRIPTION
               "This group is required for all SONET interfaces."

           GROUP       ciscoAtmIfPhysMIBDs3E3Group
           DESCRIPTION
               "This group is required for all DS3/E3 interfaces."

           GROUP       ciscoAtmIfPhysMIBDs3Group
           DESCRIPTION
               "This group is required for all DS3 interfaces."

           GROUP       ciscoAtmIfPhysMIBDs1E1Group
           DESCRIPTION
               "This group is required for all DS1/E1 interfaces."

           GROUP       ciscoAtmIfPhysMIBDs1Group
           DESCRIPTION
               "This group is required for all DS1 interfaces."

           GROUP       ciscoAtmIfPhysMIBE1Group
           DESCRIPTION
               "This group is required for all E1 interfaces."

    ::= { ciscoAtmIfPhysMIBCompliances 3 }

-- units of conformance

ciscoAtmIfPhysMIBCommonGroup OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysStatus }
    STATUS  current
    DESCRIPTION
            "A collection of objects common to all ATM physical
            layer interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 1 }

ciscoAtmIfPhysMIBSonetGroup OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysSectionParityErrors,
              ciscoAtmIfPhysLineParityErrors,
              ciscoAtmIfPhysPathParityErrors }
    STATUS  current
    DESCRIPTION
            "A collection of objects for ATM SONET interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 2 }

ciscoAtmIfPhysMIBDs3E3Group OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysLcvErrors,
              ciscoAtmIfPhysCBitParityErrors,
              ciscoAtmIfPhysPBitParityErrors,
              ciscoAtmIfPhysPlcpBipViolations }
    STATUS  current
    DESCRIPTION
            "A collection of objects for ATM DS3/E3 interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 3 }

ciscoAtmIfPhysMIBCommonGroup2 OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysCellPayloadScrambling,
              ciscoAtmIfPhysFramingMode,
              ciscoAtmIfPhysLoopbackConfig,
              ciscoAtmIfPhysTransmitClockSource,
              ciscoAtmIfPhysClockSourcePriority,
              ciscoAtmIfPhysClockSourceStatus }
    STATUS  current
    DESCRIPTION
            "Additional collection of objects common to all ATM physical
            layer interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 4 }

ciscoAtmIfPhysMIBSonetGroup2 OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysLineFebeErrors,
              ciscoAtmIfPhysPathFebeErrors,
              ciscoAtmIfPhysStsStreamScrambling }
    STATUS  current
    DESCRIPTION
            "Additional collection of objects for ATM SONET interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 5 }

ciscoAtmIfPhysMIBDs3Group OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysLineBuildOut }
    STATUS  current
    DESCRIPTION
            "Collection of objects for ATM DS3 interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 6 }

ciscoAtmIfPhysMIBDs1E1Group OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysLcvErrors,
              ciscoAtmIfPhysPlcpBipViolations,
              ciscoAtmIfPhysLineCode }
    STATUS  current
    DESCRIPTION
            "A collection of objects for ATM DS1/E1 interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 7 }

ciscoAtmIfPhysMIBDs1Group OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysDS1BitErrors }
    STATUS  current
    DESCRIPTION
            "A collection of objects for ATM DS1 interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 8 }

ciscoAtmIfPhysMIBE1Group OBJECT-GROUP
    OBJECTS { ciscoAtmIfPhysE1CrcErrors }
    STATUS  current
    DESCRIPTION
            "A collection of objects for ATM E1 interfaces."
    ::= { ciscoAtmIfPhysMIBGroups 9 }

END