AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-DOCS-EXT-MIB

CISCO-DOCS-EXT-MIB device MIB details by Cisco

CISCO-DOCS-EXT-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-DOCS-EXT-MIB.


Vendor: Cisco
Mib: CISCO-DOCS-EXT-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- *****************************************************************
-- CISCO-DOCS-EXT-MIB.my: Cisco Data Over Cable Service extension MIB file
--
-- October 1998, Minnie Lu
-- April   2001, Dhritiman Dasgupta
-- June    2001, Joline Chen
-- Oct     2001, Joline Chen
--
-- Copyright (c) 2001 by Cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************

CISCO-DOCS-EXT-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
        Integer32,
        Counter32,
        IpAddress,
        Gauge32
                FROM SNMPv2-SMI
        TruthValue,
        DisplayString,
        MacAddress,
        TimeStamp, 
        RowStatus,
        TimeInterval,
        TEXTUAL-CONVENTION
                FROM SNMPv2-TC
        OBJECT-GROUP,
        MODULE-COMPLIANCE,
        NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        ifIndex,
        InterfaceIndex
                FROM IF-MIB
        docsIfCmtsServiceEntry,
        docsIfCmtsCmStatusEntry, 
        docsIfCmtsCmStatusIndex, 
        docsIfCmtsMacEntry,
        docsIfCmtsCmStatusMacAddress,
        docsIfCmtsCmStatusIpAddress,
        docsIfCmtsCmStatusDownChannelIfIndex,
        docsIfCmtsCmStatusUpChannelIfIndex,
        docsIfUpstreamChannelEntry,
        TenthdBmV
                FROM DOCS-IF-MIB 
        ciscoMgmt
                FROM CISCO-SMI
        Unsigned32
                FROM CISCO-TC;

ciscoDocsExtMIB MODULE-IDENTITY
        LAST-UPDATED    "200110070000Z"
        ORGANIZATION    "Cisco Systems, Inc."
        CONTACT-INFO
            "        Cisco Systems
                     Customer Service

             Postal: Cisco Systems
                     170 West Tasman Drive
                     San Jose, CA 95134
                     U.S.A.
             Phone:  +1 800 553-NETS 
             E-mail: cs-ubr@cisco.com"

        DESCRIPTION
            "This is the MIB module for the Cisco specific extension 
             objects of Data Over Cable Service, Radio Frequency 
             interface.  There is a standard MIB for Data-Over-Cable 
             Service Interface Specifications (DOCSIS) and in Cisco,
             it is called DOCS-IF-MIB. Besides the objects in 
             DOCS-IF-MIB, this MIB module contains the extension 
             objects to manage the Cable Modem Termination Systems (CMTS).

             This MIB module includes objects for the scheduler 
             that supports Quality of Service (QoS) of MCNS/DOCSIS 
             compliant Radio Frequency (RF) interfaces in Cable Modem 
             Termination Systems (CMTS). And the purpose is to let 
             users configure attributes of the schedulers in 
             order to ensure the Quality of Service and fairness for 
             modem requests according to users' business needs. 
             Also this MIB shows various states of the schedulers 
             for users to monitor of the schedulers' current status. 
            
             This MIB module also includes connection status objects
             for cable modems and Customer Premise Equipment (CPE) 
             and the purpose is to let users easily get the connection 
             status and manage access group information about cable 
             modems and CPE.

             This MIB module also includes objects for upstream 
             configuration for automated spectrum management in 
             order to mitigate upstream impairment.

             This MIB module also includes objects to keep count of
             the total # of modems,# of registered and # of active 
             modems on the mac interface as well as each 
             upstream. "

        REVISION        "200110070000Z"
        DESCRIPTION
            "Added new objects cdxIfCmtsCmStatusOnlineTimesNum and
             cdxIfCmtsCmStatusLastResetTime to 
             cdxCmtsCmStatusExtTable. "

        REVISION        "200108060000Z"
        DESCRIPTION
            "DOCSIS 1.1 Changes:
             Added new objects cdxIfUpChannelAvgUtil, 
             cdxIfUpChannelAvgContSlots, 
             cdxIfUpChannelRangeSlots in 
             cdxIfUpstreamChannelExtTable. 

             NON-DOCSIS 1.1 Changes:
             Added following objects in cdxIfUpstreamChannelExtTable 
             for providing per upstream UGS statistics information:
             cdxIfUpChannelNumActiveUGS,
             cdxIfUpChannelMaxUGSLastOneHour, 
             cdxIfUpChannelMinUGSLastOneHour,
             cdxIfUpChannelAvgUGSLastOneHour, 
             cdxIfUpChannelMaxUGSLastFiveMins,
             cdxIfUpChannelMinUGSLastFiveMins, 
             cdxIfUpChannelAvgUGSLastFiveMins. "

        REVISION        "200104010000Z"
        DESCRIPTION
            "DOCSIS 1.1 Changes:
             1.  Added  cdxUpInfoElemStatsTable to display the per 
             Information Element (IE) statistics.
                
             2. Added the new queue types in cdxBWQueueNameCode to 
             support the new priority queues of the MAC-Scheduler.

             3. Added the new CM states in cdxCmtsCmStatusValue.

             Non-DOCSIS 1.1 changes:
             4. Added new status information for CM if the connection
             is noisy or if the maximum power has been reached.

             5. Changed the Description for cdxIfUpChannelWidth to
             cater for non-awacs card.

             6. Added new object cdxIfUpChannelInputPowerLevel for
             Upstream Input Power Level. "

        REVISION        "200007190000Z"
        DESCRIPTION
            "1.  Added  cdxCmtsCmTotal,cdxCmtsCmActive,
             cdxCmtsCmRegistered to the cdxCmtsMacExtTable to report 
             the number of active,registered,total cable 
             modems on a cable mac interface since boot.
             
             2.  Added cdxIfUpChannelCmTotal, cdxIfUpChannelCmActive,
             cdxIfUpChannelCmRegistered to the 
             cdxIfUpstreamChannelExtTable to report the number of 
             active,registered,total cable modems connected on an 
             upstream."

        REVISION        "200005170000Z"
        DESCRIPTION
            "1.  Added cdxCmCpeResetNow to reset CM or CPE.
             2.  Added cdxCmtsCmCurrCpeNumber to report the current
             number of CPE connecting to the CM."

        REVISION        "9912280000Z"
        DESCRIPTION
            " 1. Added new objects cdxSpecMgmtObjects. 
              2. Added new object cdxIfCmtsCmStatusDynSidCount. 
              3. Enhanced cdxQosIfRateLimitTable for a new rate limit 
                 algorithm.
              4. Added more status for cdxCmtsCmStatusValue. "

        REVISION        "9901210000Z"
        DESCRIPTION
            "Initial version of this MIB module."

        ::= { ciscoMgmt 116 }

CdxResettableCounter32 ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
        "This TC describes an object which counts events with the 
        following semantics: objects of this type will be set to
        zero(0) on creation or reset indirectly by other objects or
        certain event and will thereafter count appropriate events,
        wrapping back to zero(0) when the value 2^32 is reached.

        Provided that an application discovers the new object within
        the minimum time to wrap it can use the initial value as a
        delta since it last polled the table of which this object is
        part.

        Typically this TC is used in table where the statistical 
        information needs to be re-count after a reset. " 
        SYNTAX Gauge32 

ciscoDocsExtMIBObjects  OBJECT IDENTIFIER ::= { ciscoDocsExtMIB 1 }

cdxQosCtrlObjects OBJECT IDENTIFIER ::= { ciscoDocsExtMIBObjects 1 }
cdxQosQueueObjects OBJECT IDENTIFIER ::= { ciscoDocsExtMIBObjects 2 }
cdxCmtsCmCpeObjects OBJECT IDENTIFIER ::= { ciscoDocsExtMIBObjects 3 }
cdxSpecMgmtObjects OBJECT IDENTIFIER ::= { ciscoDocsExtMIBObjects 4 }
--
-- Scheduler QoS Control Group  
--
-- To ensure Quality of Service and fairness, the scheduler needs to 
-- control the traffic. This group includes attributes that user can 
-- configure how the scheduler controls the traffic and attributes 
-- showing the current status of the scheduler admission and rate 
-- control.     
--
-- For each Service ID, there is one Quality of Service profile 
-- associated with it. The QoS profile limits the request (upstream)/
-- packet (downstream) size for the Service ID and also defines the 
-- minimum guaranteed upstream bandwidth. Each modem's request 
-- associated with a Service ID needs to follow the Quality of 
-- Service profile constraints. 
--

--
-- Quality of Service control upstream table
--
-- Quality of Service control objects for the upstream interface
--
-- Because upstream's bandwidth(BW) is limited, the upstream scheduler 
-- needs to control the registration according to the upstream's
-- bandwidth(BW) capacity for new cable modem asking to be supported in 
-- this upstream.  This table contains the configurable objects that user 
-- can enable or disable the controlling process of the scheduler and
-- the state objects that shows the current status of the scheduler. 
--

cdxQosCtrlUpTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CdxQosCtrlUpEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "For each upstream interface, this table maintains a number 
             of objects related to Quality of Service scheduler which uses
             these attributes to control cable modem registration. "
        ::= { cdxQosCtrlObjects 1 }

cdxQosCtrlUpEntry OBJECT-TYPE
        SYNTAX      CdxQosCtrlUpEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A list of attributes for each upstream MAC scheduler 
             that supports Quality of Service.  Entries in this table
             exist for each ifEntry with ifType of docsCableUpstream(129). "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724), 
             section 6.4 and appendix C.
            
             docsIfQosProfileTable and docsIfCmtsServiceTable in 
             DOCS-IF-MIB.my. "
        INDEX { ifIndex }
        ::= { cdxQosCtrlUpTable 1 }

CdxQosCtrlUpEntry ::= SEQUENCE {
            cdxQosCtrlUpAdmissionCtrl        TruthValue,
            cdxQosCtrlUpMaxRsvdBWPercent     Integer32,
            cdxQosCtrlUpAdmissionRejects     Counter32,
            cdxQosCtrlUpReservedBW           Integer32,
            cdxQosCtrlUpMaxVirtualBW         Integer32
        }

cdxQosCtrlUpAdmissionCtrl OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "The admission control status for minimum guaranteed upstream 
           bandwidth scheduling service requests for this upstream.
           
           When this object is set to 'true', if there is a new modem 
           with minimum guaranteed upstream bandwidth scheduling service
           in its QoS class requesting to be supported in this upstream,
           the upstream scheduler will check the virtual reserved 
           bandwidth remaining capacity before giving admission to this 
           new modem. If there is not enough reserved upstream bandwidth
           to serve the modem's minimum guaranteed bandwidth, the 
           registration request will be rejected.  

           This object is set to 'false' to disable admission control.
           That is, there will be no checking for bandwidth capacity and
           the upstream interface scheduler just admits modem
           registration requests. 

           This object is not meant for Unsolicited Grant Service(UGS) 
           scheduling service as admission control is a requirement in 
           this case. "   
        ::= { cdxQosCtrlUpEntry 1 }

cdxQosCtrlUpMaxRsvdBWPercent OBJECT-TYPE
        SYNTAX      Integer32 (10..1000)
        UNITS       "percent"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
          "The percentage of upstream maximum reserved bandwidth to the 
           raw bandwidth if the admission control is enabled on this 
           upstream. 

           For example, if the upstream interface has raw bandwidth 
           1,600,000 bits/second and cdxQosCtrlUpMaxRsvdBWPercent is 200 
           percent, then this upstream scheduler will set the maximum of 
           virtual reserved bandwidth capacity to 3,200,000 bits/second 
           (1,600,000 * 2) to serve cable modems with minimum guaranteed 
           upstream bandwidth.  

           The default value is 100 percent (that is, maximum reserved 
           bandwidth is the raw bandwidth.) Whenever the admission control 
           is changed (on to off, off to on), this value will be reset to 
           the default value 100.  
    
           If the admission control is disabled, the value will be reset 
           to 100 (the default value). "  
        ::= { cdxQosCtrlUpEntry 2 }

cdxQosCtrlUpAdmissionRejects OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The count of cable modem registration requests rejected on 
             this upstream interface due to insufficient reserved 
             bandwidth for serving the cable modems with Unsolicited 
             Grant Service (UGS) scheduling service when UGS is 
             supported and for serving the cable modems with minimum 
             guaranteed bandwidth in its Quality of Service class when
             admission control is enabled on this upstream interface ."
        ::= { cdxQosCtrlUpEntry 3 }
 
cdxQosCtrlUpReservedBW OBJECT-TYPE
        SYNTAX      Integer32 (0..102400000)
        UNITS       "bits/second"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current total reserved bandwidth in bits per second of 
            this upstream interface.  It is the sum of all cable modems'
            minimum guaranteed bandwidth in bits per second currently 
            supported on this upstream. "  
        ::= { cdxQosCtrlUpEntry 4 }

cdxQosCtrlUpMaxVirtualBW OBJECT-TYPE
        SYNTAX      Integer32 (0..102400000)
        UNITS       "bits/second"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The maximum virtual bandwidth capacity of this upstream interface
             if the admission control is enabled. It is the raw bandwidth 
             in bits per second times the percentage. If the admission 
             control is disabled, then this object will contain the value 
             zero. "  
        ::= { cdxQosCtrlUpEntry 5 }

--
-- Rate Limiting table
--
-- After a cable modem is registered, upstream and downstream schedulers
-- will control the bandwidth request/packet size to ensure the Quality of 
-- Service and fairness by a rate limiting algorithm.  This table
-- contains attributes related to the rate limiting algorithms.
--

cdxQosIfRateLimitTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxQosIfRateLimitEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This table describes the attributes of rate limiting for 
            schedulers in cable upstream and downstream interfaces that 
            support Quality of Service.  The rate limiting process is 
            to ensure the Quality of Service and fairness. "
       ::= { cdxQosCtrlObjects 2 }

cdxQosIfRateLimitEntry OBJECT-TYPE
       SYNTAX      CdxQosIfRateLimitEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
            "List of the rate limiting attributes for cable upstream and 
             downstream interfaces schedulers that support Quality of 
             Service. Entries in this table exist for each ifEntry with 
             ifType of docsCableUpstream(129) and docsCableDownstream(128)."
       REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724),
             section 6.4 and appendix C.

             docsIfQosProfileTable and docsIfCmtsServiceTable in
             DOCS-IF-MIB.my. "
       INDEX { ifIndex }
       ::= { cdxQosIfRateLimitTable 1 } 

CdxQosIfRateLimitEntry ::= SEQUENCE {
           cdxQosIfRateLimitAlgm                INTEGER,
           cdxQosIfRateLimitExpWt               Integer32,
           cdxQosIfRateLimitShpMaxDelay         INTEGER,
           cdxQosIfRateLimitShpGranularity      INTEGER
       }

cdxQosIfRateLimitAlgm OBJECT-TYPE
       SYNTAX       INTEGER {
           noRateLimit(1),       -- rate limiting process is disabled
           oneSecBurst(2),       -- Bursty 1 second token bucket algorithm
           carLike(3),           -- Average token usage algorithm (CAR-like)
           wtExPacketDiscard(4), -- Weighted excess packet discard algorithm
           shaping(5)            -- token bucket algorithm with shaping
       }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "To ensure fairness, the CMTS will throttle the rate for bandwidth 
            request (upstream)/packet sent (downstream) at which CMTS issues 
            grants(upstream) or allow packet to be send(downstream) such that 
            the flow never gets more than its provisioned peak rate in bps. 

            There are two directions for every Service Id (Sid) traffic: 
            downstream and upstream. Each direction is called a service flow 
            here and assigned one token bucket with chosen algorithm. 

            The enumerations for the rate limiting algorithm are:
             noRateLimit(1): The rate limiting is disabled. No rate limiting.
             oneSecBurst(2): Bursty 1 second token bucket algorithm.
             carLike(3)    : Average token usage (CAR-like) algorithm 
             wtExPacketDiscard(4) : Weighted excess packet discard algorithm.
             shaping(5): token bucket algorithm with shaping

            Upstream supports the following: 
              No rate limiting (1), 
              Bursty 1 second token bucket algorithm(2), 
              Average token usage (CAR-like) algorithm(3),
              Token bucket algorithm with shaping(5).

            Downstream supports the following:
              No rate limiting (1), 
              Bursty 1 second token bucket algorithm(2),
              Average token usage (CAR-like) algorithm(3),
              Weighted excess packet discard algorithm(4), and
              Token bucket algorithm with shaping(5).

            Token bucket algorithm with shaping is the
            default algorithm for upstream if CMTS is in DOCSIS 1.0 mode
            or DOCSIS 1.1 mode.
            

            Bursty 1 second token bucket algorithm is the 
            default algorithm for downstream if the CMTS is in
            DOCSIS 1.0 mode. If it is in DOCSIS 1.1 mode the default
            algorithm for downstream is  Token bucket algorithm with
            shaping .

            Each algorithm is described as below:
              No rate limiting: 
                The rate limiting process is disabled and no checking 
                against the maximum bandwidth allowed. 

              Bursty 1 second token bucket rate limiting algorithm: 
                In this algorithm, at the start of every 1 second interval, 
                a service flow's token usage is reset to 0, and every time 
                the modem for that service flow sends a request (upstream) / 
                packet (downstream) the upstream/downstream bandwidth 
                token usage is incremented by the size of the 
                request/packet sent. As long as the service flow's bandwidth 
                token usage is less than the maximum bandwidth in bits 
                per second (peak rate limit) its QoS service class 
                allows, the request/packets will not be restricted. 
                Once the service flow has sent more than its peak rate in the 
                one second interval, it is prevented from sending more 
                data by rejecting request (upstream) or dropping 
                packets (downstream). This is expected to slow down
                the higher layer sources. The token usage counter gets 
                reset to 0 after the 1 second interval has elapsed. The 
                modem for that service flow is free to send more data up to the 
                peak rate limit in the new 1 second interval that follows.  

              Average token usage (Cisco CAR like) algorithm: 
                This algorithm maintains a continuous average of the 
                burst token usage of a service flow. There is no sudden 
                refilling of tokens every 1 second interval. Every time a 
                request/packet is to be handled, the scheduler tries to see 
                how much time has elapsed since last transmission, and 
                computes the number of tokens accumulated by this service flow 
                at its QoS class peak rate. If burst usage of the service flow 
                is less than tokens accumulated, the burst usage is reset to 0 
                and request/packet is forwarded. If the service flow has 
                accumulated fewer tokens than its burst usage, the burst usage 
                shows an outstanding balance usage after decrementing by the 
                tokens accumulated. In such cases, the request/packet is still 
                forwarded, provided the service flow's outstanding usage does 
                not exceed peak rate limit of its QoS class. If outstanding 
                burst usage exceeds the peak rate of the class, the service 
                flow is given some token credit up to a certain maximum credit 
                limit and the request/packet is forwarded. The request/packet 
                is dropped when outstanding usage exceeds peak rate and maximum 
                credit has been used up by this service flow. This algorithm 
                tracks long term average bandwidth usage of the service flow 
                and controls this average usage at the peak rate limit.

              Weighted excess packet discard algorithm:
                This rate limiting algorithm is only available as an option 
                for downstream rate limiting. The algorithm is to maintain an 
                weighted exponential moving average of the loss rate of a 
                service flow over time. The loss rate, expressed in packets, 
                represents the number of packets that can be sent from this 
                service flow in a one second interval before a packet will 
                be dropped. At every one second interval, the loss rate gets 
                updated using the ratio between the flow peak rate (in bps) 
                in its QoS profile and the service flow actual usage (in bps). 
                If the service flow begins to send more than its peak rate 
                continuously, the number of packets it can send in an one 
                second interval before experiencing a drop will slowly keep 
                reducing until cable modem for that service flow slows down 
                as indicated by actual usage less or equal to the peak rate. 

              Token bucket algorithm with shaping:
                 If there is no QoS class peak rate limit, forward the 
                 request/packet without delay. If there is a QoS peak rate 
                 limit, every time a request/packet is to be handled, the 
                 scheduler determines the number of bandwidth tokens that this 
                 service flow has accumulated over the elapsed time at its 
                 QoS class peak rate and increments the tokens counter of the 
                 service flow accordingly.  The scheduler limits the token 
                 count to the maximum transmit burst (token bucket depth).  
                 If token count is greater than the number of tokens required 
                 to handle current request/packet, decrement token count by 
                 size of request/packet and forwards the request/packet 
                 without delay.  If token count is less than the size of 
                 request/packet, compute the shaping delay time after 
                 which the deficit number of tokens would be available. If 
                 shaping delay time is less than the maximum shaping delay, 
                 decrement tokens count by size of request/packet and 
                 forward this request/packet with the shaping delay in the 
                 shaping delay queue. When the delay time expires, the 
                 request/packet is forwarded. If shaping delay time is 
                 greater than the maximum shaping delay that the subsequent 
                 shaper can handle, the request/packet is dropped. Users can
                 use cdxQosIfRateLimitShpMaxDelay to configure the the maximum 
                 shaping delay and cdxQosIfRateLimitShpGranularity to 
                 configure the shaping granularity.  "
       ::= { cdxQosIfRateLimitEntry 1 }

cdxQosIfRateLimitExpWt OBJECT-TYPE
       SYNTAX      Integer32 (1..4)
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "Weight for exponential moving average of loss rate for 
            weighted excess packet discard algorithm to maintain.
            The higher value of the weight makes the algorithm
            more sensitive to the recent bandwidth usage by the Sid. 
        
            The default value is 1 and whenever the rate limiting
            algorithm is changed to weighted excess packet discard 
            algorithm, this value will be reset to the default 1.

            If the rate limiting algorithm is not weighted excess 
            packet discard algorithm, the value will be always the 
            default value 1. "
       ::= { cdxQosIfRateLimitEntry 2 }

cdxQosIfRateLimitShpMaxDelay OBJECT-TYPE
       SYNTAX       INTEGER {
           na(1),   
           msec128(2),  
           msec256(3),  
           msec512(4),  
           msec1024(5)  
       }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The maximum shaping delay in milliseconds. That is, the maximum 
            amount time of buffering the CMTS will allow for any rate exceeded 
            flow.  If the max buffering delay is large, the grants/packets of 
            the flow will be buffered for a longer period of time even though 
            the flow is rate exceeded. This means fewer chances of drops for
            such rate exceeded flow. However, too large a max shaping delay 
            can result is quick drainage of packet buffers at the CMTS, since 
            several packets will be in the shaping (delay) queue waiting for 
            their proper transmission time. Another important point to be noted 
            is that delaying a flows packets (especially TCP flows) for 
            extended periods of time is useless, since the higher protocol 
            layers may assume a packet loss after a certain amount of time.
 
            The maximum shaping delay is only applied to rate limit algorithm: 
            Token bucket algorithm with shaping.  If the rate limit 
            algorithm is not Token bucket algorithm with shaping, the 
            value is always na(1) which is not applicable.

            If the token count is less than the size of request/packet, CMTS 
            computes the shaping delay time after which the deficit number of 
            tokens would be available. If the shaping delay time is greater 
            than the maximum shaping delay, the request/packet will be dropped.  

            The enumerations for maximum shaping delay are:
              na(1): maximum shaping delay is not applied to the current 
                     rate limit algorithm
             msec128(2): maximum shaping delay is 128 milliseconds  
             msec256(3): maximum shaping delay is 256 milliseconds 
             msec512(4): maximum shaping delay is 512 milliseconds 
            msec1024(5): maximum shaping delay is 1024 milliseconds 

            The downstream maximum shaping delay is configurable and the
            default value is msec128(2). Whenever the downstream rate 
            limit algorithm is changed to Token bucket algorithm with 
            shaping from other rate limit algorithm, the value will 
            be reset to the default value. 

            The upstream maximum shaping delay is not configurable and it 
            is read-only value.  "
       ::= { cdxQosIfRateLimitEntry 3 }

cdxQosIfRateLimitShpGranularity OBJECT-TYPE
       SYNTAX       INTEGER {
           na(1), 
           msec1(2),  
           msec2(3),  
           msec4(4),  
           msec8(5),  
           msec16(6)  
       }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
           "The width in milliseconds of each element in shaping 
            delay queue, that is, the shaping granularity.

            The shaping granularity is only applied to rate limit
            algorithm: Token bucket algorithm with shaping. It 
            controls how accurately the algorithm quantizes the shaping 
            delay for a rate exceeded flow. If granularity is large, several 
            shaping delay values will all be quantized to the same element 
            in the queue resulting in less accurate rate shaping for the flows 
            in bits/sec. On the other hand, choosing too small granularity 
            causes more memory to be used for the shaper block, and also 
            can cost a bit more in runtime overhead.
 
            If the rate limit algorithm is not Token bucket algorithm with 
            shaping, the value is always na(1) which is not applicable.

            The enumerations for shaping granularity are:
              na(1): shaping granularity is not applied to the current 
                     rate limit algorithm
               msec1(2): shaping granularity in 1 milliseconds 
               msec2(3): shaping granularity in 2 milliseconds 
               msec4(4): shaping granularity in 4 milliseconds 
               msec8(5): shaping granularity in 8 milliseconds 
              msec16(6): shaping granularity in 16 milliseconds  

            The downstream shaping granularity is configurable and the
            default value is msec4(4). Whenever the downstream rate limit 
            algorithm is changed to Token bucket algorithm with shaping 
            from other rate limit algorithm, the value will be reset to the 
            default value. 

            The upstream shaping granularity is not configurable and 
            it is read-only value.  "
       ::= { cdxQosIfRateLimitEntry 4 }




--
-- Cmts Service Extension Table
-- 
-- This table extends the information about a Service ID in
-- docsIfCmtsServiceTable. 
--
-- For each Service ID, there is one Quality of Service profile 
-- associated with it and the profile limits the request/packet size
-- for the Service ID. This table shows downstream traffic statistics
-- and the various counts that the Service ID exceeds the limit in its 
-- Quality of Service profile. 
--

cdxCmtsServiceExtTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmtsServiceExtEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The list contains the additional attributes of a single Service
            ID that provided by docsIfCmtsServiceEntry. "
       ::= { cdxQosCtrlObjects 3 }

cdxCmtsServiceExtEntry OBJECT-TYPE
        SYNTAX      CdxCmtsServiceExtEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
          "Additional objects for docsIfCmtsServiceTable entry including 
           downstream traffic statistics and excess counts against the 
           Quality of Service limits for each Service ID.
           From DOCSIS 1.1 onwards statistics are maintained for each 
           Service Flow(instead of the Service ID) in the DOCS-QOS-MIB 
           in docsQosServiceFlowStatsTable objects. The objects  
           cdxIfCmtsServiceOutOctets and cdxIfCmtsServiceOutPackets
           are applicable only if the Cable modem is running in 
           DOCSIS 1.0 mode. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724),
             section 6.4 and appendix C.

             docsIfQosProfileTable and docsIfCmtsServiceTable in
             DOCS-IF-MIB.my. "
        AUGMENTS { docsIfCmtsServiceEntry }
        ::= { cdxCmtsServiceExtTable 1 }

CdxCmtsServiceExtEntry ::= SEQUENCE {
            cdxIfCmtsServiceOutOctets       Counter32,
            cdxIfCmtsServiceOutPackets      Counter32,
            cdxQosMaxUpBWExcessRequests     Counter32,
            cdxQosMaxDownBWExcessPackets    Counter32
        }

cdxIfCmtsServiceOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The cumulative number of Packet Data octets sent for this 
             Service ID. " 
        ::= { cdxCmtsServiceExtEntry 1 }

cdxIfCmtsServiceOutPackets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The cumulative number of Packet data packets sent for this 
             Service ID. "
        ::= { cdxCmtsServiceExtEntry 2 }


cdxQosMaxUpBWExcessRequests OBJECT-TYPE
        SYNTAX      Counter32 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of upstream bandwidth requests which exceeds the
             maximum upstream bandwidth allowed for a service defined 
             in the Quality of Service profile associated with this Sid. 
             The request which exceeds the maximum upstream bandwidth 
             allowed will be rejected by the upstream's rate limiting 
             process using one of the rate limiting algorithm. 

             Note that the value of this counter cannot be directly used 
             to know the number of upstream packets that got dropped at 
             the cable modem.  A single upstream packet drop of a modem 
             can result in up to 16 increments in this counter, since the 
             modem keeps retrying and keeps getting bandwidth request 
             drops at CMTS if it has consumed its peak rate.  " 
        REFERENCE
            "docsIfQosProfMaxUpBandwidth object in DOCS-IF-MIB.my. "
        ::= { cdxCmtsServiceExtEntry 3 }

cdxQosMaxDownBWExcessPackets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of downstream bandwidth packets which exceeds the
             maximum downstream bandwidth allowed for a service defined
             in the Quality of Service profile associated with this Sid. 
             The packet which exceeds the maximum downstream bandwidth 
             allowed will be dropped by the downstream's rate limiting 
             process using one of the rate limiting algorithm. "
        REFERENCE
            "docsIfQosProfMaxDownBandwidth object in DOCS-IF-MIB.my. "
        ::= { cdxCmtsServiceExtEntry 4 }



-- Upstream Information Element Statistics Table
--
-- This table contains the CMTS upstream Mac scheduler statistics for 
-- each type of Information Element (IE).
--
-- The CMTS upstream channel is modeled as a stream of mini-slots.
-- The CMTS generates the allocation MAP to define transmission 
-- opportunities on the upstream channel. The MAP defines a variable 
-- number of Information Elements (IE) which defines the allowed usage
-- for a range of mini-slots.
--
-- The Information provided in this table could be dynamic depending on 
-- how the the mini-slots are used.

cdxUpInfoElemStatsTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CdxUpInfoElemStatsEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The table contains the attributes of a particular 
             Information Element type for each instance of the MAC 
             scheduler. It is indexed by upstream ifIndex. An Entry
             exists for each ifEntry with ifType of docsCableUpstream(129)
             Since each upstream has an instance of a MAC Scheduler so 
             this table has the per MAC scheduler slot information on a
             per Information Element basis. "
       ::= { cdxQosCtrlObjects 4 }
       
cdxUpInfoElemStatsEntry OBJECT-TYPE
        SYNTAX      CdxUpInfoElemStatsEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The list of statistics for a type of Information Element(IE)
              which defines the allowed usage for a range of upstream mini
              slots. One entry exists for each Information Element (IE) in
              a upstream which ifType is docsCableUpstream (12)."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I05-000714)
             section 7.1.2 "
        INDEX { ifIndex, cdxUpInfoElemStatsNameCode }
        ::= { cdxUpInfoElemStatsTable 1 }     
         
CdxUpInfoElemStatsEntry ::= SEQUENCE {
            cdxUpInfoElemStatsNameCode           INTEGER,
            cdxUpInfoElemStatsIEType             Integer32
        } 
        
cdxUpInfoElemStatsNameCode OBJECT-TYPE
        SYNTAX      INTEGER {
                    reqIE(1),
                    reqOrDataIE(2),
                    initMtnIE(3),
                    stnMtnIE(4),
                    shortGrantIE(5),
                    longGrantIE(6)
        }                   
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This entry describes the Information Element (IE) type.
             Enumerations are :
             reqIE(1)          : Request Information Element,
                                 The request Information Element provides
                                 an upstream interval in which a CM can
                                 request the CMTS for bandwidth on the 
                                 upstream channel.
             reqOrDataIE(2)    : Request/Data Information Element,
                                 The Request/data Information Element 
                                 provides an upstream interval in which 
                                 request may be made by the CM to the 
                                 CMTS for bandwidth or short data 
                                 packets may be transmitted on the
                                 upstream channel.
             initMtnIE(3)      : Initial Maintenance Information Element,
                                 The Initial Maintenance Information 
                                 Element provides an interval in which 
                                 new stations may join the network.
             stnMtnIE(4)       : Station Maintenance Information Element,
                                 The Station Maintenance Information 
                                 Element provides an interval in which 
                                 stations are expected to perform some 
                                 aspect of routine network maintenance , 
                                 such as ranging or power adjustment.
             shortGrantIE(5)   : Short Data Grant Information Element,
                                 Short data grant Information Element
                                 provides the CM an opportunity to 
                                 transmit one or more upstream PDU's.
                                 Short data grants are used with 
                                 intervals equal to or less than the 
                                 maximum burst size for the usage 
                                 specified in the Upstream Channel 
                                 Descriptor.
             longGrantIE(6)    : Long Data Grant Information Element,
                                 The long data grant Information Element
                                 also provides the CM an opportunity to
                                 transmit one or more upstream PDU's.
                                 All long data grant Information Elements
                                 must have a larger number of mini-slots
                                 than that defined for a short data grant
                                 Information Element profile defined in
                                 the Upstream Channel Descriptor. "
        ::= { cdxUpInfoElemStatsEntry  1 }
        
cdxUpInfoElemStatsIEType OBJECT-TYPE
        SYNTAX      Integer32 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current number of mini-slots used for the Information 
             Element type. The value is only a snapshot since the 
             current number of mini-slots of this IE type could be
             changing rapidly. "
        ::= {cdxUpInfoElemStatsEntry 2 }

                
-- Scheduler QoS Queue Group
--
-- To ensure Quality of Service and fairness, the scheduler
-- maintains a set of queues for different services and puts  
-- cable modems requests/packets for that Sid in different 
-- queue according to the Quality of Service profile of the 
-- Sid.  Each queue has a name and order within the queue set.  
-- The scheduler will serve the requests/packets in higher 
-- order queue before serving the requests/packets in lower
-- order queue. 
--

--
-- Scheduler bandwidth request queues table 
--
-- This table displays the attributes for these queues in a cable
-- interface scheduler that supports Quality of Service.
--

cdxBWQueueTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CdxBWQueueEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table describes the attributes of queues  
             in cable interfaces schedulers that support 
             Quality of Service."
        ::= { cdxQosQueueObjects 1 }

cdxBWQueueEntry OBJECT-TYPE
        SYNTAX      CdxBWQueueEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The list of queue attributes in cable upstream and downstream
             interfaces schedulers that supports Quality of Service. 
             Entries in this table exist for each ifEntry with ifType of 
             docsCableUpstream(129) and docsCableDownstream(128). "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724), 
             section 6.4 and appendix C. "
        INDEX { ifIndex,cdxBWQueueNameCode }
        ::= { cdxBWQueueTable 1 }

CdxBWQueueEntry ::= SEQUENCE {
            cdxBWQueueNameCode                 INTEGER,
            cdxBWQueueOrder                    Integer32,
            cdxBWQueueNumServedBeforeYield     Integer32,
            cdxBWQueueType                     INTEGER,
            cdxBWQueueMaxDepth                 Integer32,
            cdxBWQueueDepth                    Integer32,
            cdxBWQueueDiscards                 Counter32
        } 



cdxBWQueueNameCode OBJECT-TYPE 
        SYNTAX       INTEGER {
            cirQ(1),         -- Committed Information Rate Queue
            tbeQ(2),         -- TIERED BEST EFFORT queue
            p0BEGrantQ(3),   -- Priority 0 Best Effort Grant Queue
            p1BEGrantQ(4),   -- Priority 1 Best Effort Grant Queue
            p2BEGrantQ(5),   -- Priority 2 Best Effort Grant Queue
            p3BEGrantQ(6),   -- Priority 3 Best Effort Grant Queue
            p4BEGrantQ(7),   -- Priority 4 Best Effort Grant Queue
            p5BEGrantQ(8),   -- Priority 5 Best Effort Grant Queue
            p6BEGrantQ(9),   -- Priority 6 Best Effort Grant Queue
            p7BEGrantQ(10),  -- Priority 7 Best Effort Grant Queue
            rngPollQ(11)     -- Priority 9 ranging Poll Queue
        }
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The name code for the queue.
                    
             cirQ :CIR queue. The queue is for Committed Information Rate 
                   (CIR) type of service which serves Service IDs which
                   have minimum guaranteed rate in its QoS profile.
                   It is applicable if CMTS is running is either of 
                   DOCSIS 1.0 or 1.1 modes.For DOCSIS 1.1 it has 
                   priority 8.
                              
             tbeQ :TBE Queue.The queue is for TIERED BEST EFFORT type 
                   service which serves Service IDs which does not have 
                   minimum guaranteed rate in its QoS profile. It is 
                   only applicable if CMTS is running in DOCSIS 1.0
                   mode.

             p0BEGrantQ-p7BEGrantQ : BEST EFFORT Queue
                   The queues p0BEGrantQ to P7BEGrantQ are for TIERED 
                   BEST EFFORT type service which serves Service IDs 
                   which do not have minimum guaranteed rate specified
                   in the QoS parameters. P0 has lowest priority and P7
                   has highest.Best Effort type is purely handled with 
                   prioritization in FIFO's and hence demands more 
                   number of queues. These queues are applicable only if
                   CMTS is running under mode DOCSIS 1.1.
                                          
             rngPollQ : RngPoll queue.
                   The queue is for the ranging SID's.It has the highest
                   priority. This queue information is only provided if
                   CMTS is running under mode DOCSIS 1.1. "         
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification(SP-RFI-I06-001215) 
             section 6.4 and appendix C."
        ::= { cdxBWQueueEntry 1 }
        
cdxBWQueueOrder OBJECT-TYPE
        SYNTAX      Integer32 (0..10)
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "The relative order of this queue to the other queues within the 
             cable interface. The smaller number has higher order. That is,
             0 is the highest order and 10 is the lowest order.  The 
             scheduler will serve the requests in higher order queue up to 
             the number of requests defined in cdxBWQueueNumServedBeforeYield
             before serving requests in the next higher order queue.  

             If there are n queues on this interface, the queue order will 
             be 0 to n-1 and maximum number of requests defined as 
             cdxBWQueueNumServedBeforeYield in order 0 queue will be served 
             before the requests in order 1 queue to be served. "
        ::= { cdxBWQueueEntry 2 }

cdxBWQueueNumServedBeforeYield OBJECT-TYPE
        SYNTAX      Integer32 (0..64)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The maximum number of requests/packets the scheduler can 
            serve before yielding to another queue. The value 0 means all 
            requests must be served before yielding to another queue. The 
            range is 0-50 for DOCSIS 1.0 and for DOCSIS 1.1 it is 0-64. "
        ::= { cdxBWQueueEntry 3 }


cdxBWQueueType OBJECT-TYPE
        SYNTAX      INTEGER {
            unknown(1),
            other(2),
            fifo(3),
            priority(4)
        }
        MAX-ACCESS read-only
        STATUS      current
        DESCRIPTION
            "The queuing type which decides the position of a request/packet
             within the queue.
               unknown : queue type unknown. 
               other   : not fifo, and not priority.
               fifo    : first in first out.
               priority: each bandwidth request has a priority and the 
                         position of the request within the queue depends 
                         on its priority.
               For DOCSIS1.1 all the priority queues are fifo queues. "
        ::= { cdxBWQueueEntry 4 }


cdxBWQueueMaxDepth OBJECT-TYPE
        SYNTAX      Integer32 (0..64) 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The maximum number of requests/packets which the queue can 
             support.The range is 0-50 for DOCSIS1.0 and for
             DOCSIS1.1 it is 0-64. "
        ::= { cdxBWQueueEntry 5 }


cdxBWQueueDepth OBJECT-TYPE
        SYNTAX      Integer32 (0..64) 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current number of requests/packets in the queue.
             The range is 0-50 for DOCSIS1.0 and for
             DOCSIS1.1 it is 0-64. "
        ::= { cdxBWQueueEntry 6 }


cdxBWQueueDiscards OBJECT-TYPE
        SYNTAX      Counter32 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of requests/packets discarded because of queue
             overflow (queue depth > queue maximum depth). " 
        ::= { cdxBWQueueEntry 7 }


--
-- CMTS Cable Modem (CM) Customer Premises Equipments (CPE) Group
--
-- This group contains tables in CMTS for information about  
-- Cable Modems (CM) and Customer Premises Equipments (CPE) 
-- that connects to Cable Modems.
--

--
-- Cable modem (CM) or Customer Premises Equipments (CPE) Table
--
-- For the information of CM or CPE maintained in CMTS. 
--

cdxCmCpeTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmCpeEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This table contains information about cable modems (CM) or 
            Customer Premises Equipments (CPE). "
       ::= { cdxCmtsCmCpeObjects 1 }

cdxCmCpeEntry OBJECT-TYPE
        SYNTAX      CdxCmCpeEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
           "The list contains information for a cable modem (CM) or a
            Customer Premises Equipment (CPE). An entry exist for 
            each cable modem supported by CMTS and each Customer Premises 
            Equipment connected to a cable modem supported by CMTS. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724.)
             docsIfCmtsCmStatusTable, docsIfCmtsServiceTable in 
             DOCS-IF-MIB.my. "
        INDEX { cdxCmCpeMacAddress }
        ::= { cdxCmCpeTable 1 }

CdxCmCpeEntry ::= SEQUENCE {
            cdxCmCpeMacAddress           MacAddress,
            cdxCmCpeType                 INTEGER,
            cdxCmCpeIpAddress            IpAddress,
            cdxCmCpeIfIndex              InterfaceIndex,
            cdxCmCpeCmtsServiceId        Integer32, 
            cdxCmCpeCmStatusIndex        Integer32,
            cdxCmCpeAccessGroup          DisplayString,
            cdxCmCpeResetNow             TruthValue
        }

cdxCmCpeMacAddress OBJECT-TYPE
        SYNTAX      MacAddress
        MAX-ACCESS  not-accessible 
        STATUS      current
        DESCRIPTION
            "The Mac address to identify a cable modem or a Customer 
             Premises Equipment. "
        ::= { cdxCmCpeEntry 1 }

cdxCmCpeType OBJECT-TYPE
        SYNTAX      INTEGER {
            cm(1),  
            cpe(2) 
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Indicate this entry is for cable modem or Customer Premises 
             Equipment.  The enumerations are: 
              cm(1): cable modem
              cpe(2): Customer Premises Equipment " 
        ::= { cdxCmCpeEntry 2 }


cdxCmCpeIpAddress  OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Ip address of the cable modem or Customer Premises Equipment. " 
        ::= { cdxCmCpeEntry 3 }


cdxCmCpeIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndex 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The CMTS cable MAC interface index (ifType of 
             docsCableMaclayer(127)) that cable modem or Customer Premises 
             Equipment connects to.  

             Use cdxCmCpeIfIndex and cdxCmCpeCmtsServiceId to indentify an 
             entry in docsIfCmtsServiceTable.  " 
        ::= { cdxCmCpeEntry 4 }

cdxCmCpeCmtsServiceId  OBJECT-TYPE
        SYNTAX      Integer32(1..16383) 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The cable modem's primary Service ID if the type is cm. 
             The primary Service ID for the CM which the CPE connects if the 
             type is cpe.

             Use cdxCmCpeIfIndex and cdxCmCpeCmtsServiceId to identify an 
             entry in docsIfCmtsServiceTable.  " 
        ::= { cdxCmCpeEntry 5 }


cdxCmCpeCmStatusIndex OBJECT-TYPE 
        SYNTAX      Integer32(1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Pointer to an entry in docsIfCmtsCmStatusTable identifying 
             status of the CM (which the CPE connects to.) "
        ::= { cdxCmCpeEntry 6 }

cdxCmCpeAccessGroup OBJECT-TYPE    
        SYNTAX      DisplayString 
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "ASCII text to identify the Access Group for a CM or CPE. 
             Access Group is to filter the upstream traffic for that
             CM or CPE.  "
        ::= { cdxCmCpeEntry 7 }

cdxCmCpeResetNow OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Setting this object to true(1) causes the device to 
             reset.  Reading this object always returns false(2).
 
             For cdxCmCpeType value cm(1),  CMTS removes the 
             CM from the Station Maintenance List and would cause 
             the CM to reset its interface.
 
             For cdxCmCpeType value cpe(2), CMTS removes the 
             CPE's MAC address from the internal address table.  
             It then rediscovers and associates the CPE with the 
             correct CM during the next DHCP lease cycle.  By resetting 
             the CPE, the user can replace an existing CPE or change 
             its network interface card (NIC).
            "
        ::= { cdxCmCpeEntry 8 }

--
-- CMTS CM status extension table
--
-- This table extends the CM status information in docsIfCmtsCmStatusTable
--

cdxCmtsCmStatusExtTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmtsCmStatusExtEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "The list contains the additional CM status information. "
       ::= { cdxCmtsCmCpeObjects 2 }

cdxCmtsCmStatusExtEntry OBJECT-TYPE
        SYNTAX      CdxCmtsCmStatusExtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Additional objects for docsIfCmtsCmStatusTable entry. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724.)
             docsIfCmtsCmStatusTable in DOCS-IF-MIB.my. "
        AUGMENTS { docsIfCmtsCmStatusEntry }
        ::= { cdxCmtsCmStatusExtTable 1 }

CdxCmtsCmStatusExtEntry ::= SEQUENCE {
            cdxCmtsCmStatusValue             INTEGER,
            cdxIfCmtsCmStatusOnlineTimes     Counter32,
            cdxIfCmtsCmStatusPercentOnline   Integer32,
            cdxIfCmtsCmStatusMinOnlineTime   TimeInterval,
            cdxIfCmtsCmStatusAvgOnlineTime   TimeInterval,
            cdxIfCmtsCmStatusMaxOnlineTime   TimeInterval,
            cdxIfCmtsCmStatusMinOfflineTime  TimeInterval,
            cdxIfCmtsCmStatusAvgOfflineTime  TimeInterval,
            cdxIfCmtsCmStatusMaxOfflineTime  TimeInterval,
            cdxIfCmtsCmStatusDynSidCount     Integer32,
            cdxIfCmtsCmStatusAddlInfo        BITS,
            cdxIfCmtsCmStatusOnlineTimesNum  CdxResettableCounter32,
            cdxIfCmtsCmStatusLastResetTime   TimeStamp         
        }

cdxCmtsCmStatusValue OBJECT-TYPE
        SYNTAX       INTEGER {
            offline(1),         
            others(2),          
            initRangingRcvd(3), 
            initDhcpReqRcvd(4), 
            onlineNetAccessDisabled(5), 
            onlineKekAssigned(6),  
            onlineTekAssigned(7), 
            rejectBadMic(8),      
            rejectBadCos(9),    
            kekRejected(10),    
            tekRejected(11),     
            online(12),
            initTftpPacketRcvd(13),
            initTodRequestRcvd(14),
            reset(15),          
            rangingInProgress(16),
            rangingCompleted(17), 
            dhcpGotIpAddr(18),
            rejStaleConfig(19),
            rejIpSpoof(20),
            rejClassFail(21), 
            rejRegNack(22), 
            bpiKekExpired(23),
            bpiTekExpired(24),     
            shutdown(25)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current Cable Modem connectivity state. The object extends 
             states in docsIfCmtsCmStatusValue in more details. 

             The enumerations are:
             offline(1)                : modem considered offline.
             others(2)                 : states is in 
                                         docsIfCmtsCmStatusValue.
             initRangingRcvd(3)        : modem sent initial ranging.
             initDhcpReqRcvd(4)        : dhcp request received.
             onlineNetAccessDisabled(5): modem registered, but network    
                                         access for the CM is disabled.
             onlineKekAssigned(6)      : modem registered, BPI enabled
                                         and KEK assigned.
             onlineTekAssigned(7)      : modem registered, BPI enabled
                                         and TEK assigned.
             rejectBadMic(8)           : modem did attempt to register but
                                         registration was refused due to
                                         bad mic.
             rejectBadCos(9)           : modem did attempt to register but
                                         registration was refused due to
                                         bad COS.
             kekRejected(10)           : KEK modem key assignment rejected.
             tekRejected(11)           : TEK modem key assignment rejected.
             online(12)                : modem registered, enabled for data.
             initTftpPacketRcvd(13)    : tftp packet received and option
                                         file tranfer started. 
             initTodRquestRcvd(14)     : Time of the Day (TOD) request 
                                         received.
             reset(15)                 : modem is resetting.
             rangingInProgress(16)     : initial ranging is in progress.
             rangingCompleted(17)      : initial ranging is completed.
             dhcpGotIpAddr(18)         : modem has got an IP address 
                                         from the DHCP server.
             rejStaleConfig(19)        : modem did attempt to register
                                         but registration was refused
                                         due to stale Config.
             rejIpSpoof(20)            : modem did attempt to register but
                                         registration was refused due to IP
                                         Spoof.
             rejClassFail(21)          : modem did attempt to register but
                                         registration was refused due to 
                                         Class failure.
             rejRegNack(22)            : modem did attempt to register but
                                         no acknowledgement was recieved.
             bpiKekExpired(23)         : KEK modem key assignment expired.
             bpiTekExpired(24)         : TEK modem key assignment expired.
             shutdown(25)              : modem is in shutdown state.

            
            
            FOR DOCSIS 1.0
            --------------
             The ranging, rangingAborted, rangingComplete, and ipComplete 
             states in docsIfCmtsCmStatusValue is others in this object
             since this object is extension of docsIfCmtsCmStatusValue. 

             The registrationComplete state in docsIfCmtsCmStatusValue 
             could be online, onlineNetAccessDisabled, onlineKekAssigned, or 
             onlineTekAssigned in this object.  

             The accessDenied state in docsIfCmtsCmStatusValue could be 
             rejectBadMic, rejectBadCos in this object for the possible
             reasons of cable modem registration abort.
             
             The states 15 to 25 are not applicable.
             
            FOR DOCSIS 1.1
            -------------- 
                         
             The registrationComplete state in docsIfCmtsCmStatusValue 
             could be online, onlineNetAccessDisabled, 
             onlineBpiKekAssigned,or onlineBpiTekAssigned in this 
             object.  

             The accessDenied state in docsIfCmtsCmStatusValue could be 
             rejMicFail, rejStaleConfig, rejIpSpoof, rejClassFail, 
             rejRegNack in this object for the possible reasons of cable
             modem registration abort.

             The CMTS only reports states it is able to detect.States
             Online(2) and  rejectBadCos(9) are not applicable. "
             
             
        ::= { cdxCmtsCmStatusExtEntry 1 }

cdxIfCmtsCmStatusOnlineTimes OBJECT-TYPE
        SYNTAX      Counter32 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of times that the modem changes the connectivity 
             state from 'offline' to 'online' over the time period from 
             the modem's first ranging message received by CMTS until 
             now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 2 }

cdxIfCmtsCmStatusPercentOnline OBJECT-TYPE
        SYNTAX      Integer32 (0..10000)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The percentage of time that the modem stays 'online' over 
             the time period from the modem's first ranging message 
             received by CMTS until now. 

             The value for this object is 100 times bigger than the real 
             percentage value. For example, 32.15% will be value 3215.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 3 }

cdxIfCmtsCmStatusMinOnlineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The minimum period of time the modem stayed 'online' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 4 }


cdxIfCmtsCmStatusAvgOnlineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average period of time the modem stayed 'online' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 5 }

cdxIfCmtsCmStatusMaxOnlineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The maximum period of time the modem stayed 'online' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 6 }

cdxIfCmtsCmStatusMinOfflineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The minimum period of time modem stayed 'offline' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 7 }


cdxIfCmtsCmStatusAvgOfflineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average period of time the modem stayed 'offline' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 8 }

cdxIfCmtsCmStatusMaxOfflineTime OBJECT-TYPE
        SYNTAX      TimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The maximum period of time the modem stayed 'offline' over
             the time period from the modem's first ranging message 
             received by CMTS until now.

             The modem is considered as 'online' when the value for 
             cdxCmtsCmStatusValue is any of the values: online(5), 
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and 
             onlineTekAssigned(8), and the modem is considered as 
             'offline' for other values for cdxCmtsCmStatusValue.  "
        REFERENCE
            "cdxCmtsCmStatusValue object."
        ::= { cdxCmtsCmStatusExtEntry 9 }

cdxIfCmtsCmStatusDynSidCount OBJECT-TYPE
        SYNTAX      Integer32(0..16383)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of active dynamic SIDs on this modem.
             Prior to getting the assigned the Service Flow IDs(SFID)
             the CM must must complete a number of protocol 
             transactions. The CMTS assigns a temporary Service ID
             (SID) to complete these steps." 
        ::= { cdxCmtsCmStatusExtEntry 10 }

cdxIfCmtsCmStatusAddlInfo OBJECT-TYPE
        SYNTAX      BITS {
                          noisyPlant(0),
                          modemPowerMaxOut(1)
                    }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates additional attributes regarding
             the CM.
             1. noisyPlant indicates that the CM connection is noisy.
             2. modemPowerMaxOut indicates that the modem has reached
             its maximum power level.

             A bit of of this object is set to 1 if the condition
             indicated by the bit is satisfied.

             Note that BITS are encoded most significant bit
             first. "
        ::= { cdxCmtsCmStatusExtEntry 11 }

cdxIfCmtsCmStatusOnlineTimesNum OBJECT-TYPE
        SYNTAX      CdxResettableCounter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of times that the modem changes the connectivity
             state from 'offline' to 'online' over the time period from
             the modem's first ranging message received by CMTS until now.

             The modem is considered as 'online' when the value for
             cdxCmtsCmStatusValue is any of the values: online(5),
             onlineNetAccessDisabled(6), onlineKekAssigned(7), and
             onlineTekAssigned(8), and the modem is considered as 'offline'
             for other values for cdxCmtsCmStatusValue.

             The value of this object is reset to 0 if the value in
             cdxIfCmtsCmStatusLastResetTime is changed. "
        ::= { cdxCmtsCmStatusExtEntry 12 }

cdxIfCmtsCmStatusLastResetTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The last cable modem connectivity statistics reset time. If
             the value of  this object is '0', then the cable modem
             connectivity statistics had not been reset."
        ::= { cdxCmtsCmStatusExtEntry 13 }

--
-- CMTS MAC extension Table
--
-- This table extends the attributes for CMTS MAC interface.
--
-- This table includes attributes of the cable modem notification 
-- enabling/disabling and the interval of cable modem notification sent 
-- by the CMTS for a cable modem that the Mac interface supports.
--
       
cdxCmtsMacExtTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmtsMacExtEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This table contains the additions attributes of a CMTS MAC
            interface that provided by docsIfCmtsMacTable. "  
       ::= { cdxCmtsCmCpeObjects 3 }

cdxCmtsMacExtEntry OBJECT-TYPE
        SYNTAX      CdxCmtsMacExtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Additional objects for docsIfCmtsMacTable entry including
             the cable modem notification enable/disable and the interval 
             of cable modem notification sent by the CMTS for a cable modem
             that the Mac interface supports. An entry in this table exists 
             for each ifEntry with an ifType of docsCableMaclayer(127).
             Additional objects added to determine the number of 
             active/registered/total cable modems on this cable mac 
             interface since boot. "
        REFERENCE
            "docsIfCmtsMacTable in DOCS-IF-MIB.my. "
        AUGMENTS { docsIfCmtsMacEntry }
        ::= { cdxCmtsMacExtTable 1 }

CdxCmtsMacExtEntry ::= SEQUENCE {
            cdxCmtsCmOnOffTrapEnable       TruthValue,
            cdxCmtsCmOnOffTrapInterval     Integer32,
            cdxCmtsCmDefaultMaxCpes        Integer32,
            cdxCmtsCmTotal                 Integer32,
            cdxCmtsCmActive                Integer32,
            cdxCmtsCmRegistered            Integer32
        }

cdxCmtsCmOnOffTrapEnable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "An indication of whether the cdxCmtsCmOnOffNotification 
             is enabled. The default value is false(2). "
        ::= { cdxCmtsMacExtEntry 1 }
        
cdxCmtsCmOnOffTrapInterval OBJECT-TYPE
        SYNTAX      Integer32 (0..86400)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The interval for cdxCmtsCmOnOffNotification sent by CMTS for
             one online/offline state change if cdxCmtsCmOnOffTrapEnable 
             is true. 

             If there are more than one state changes to online/offline 
             for a cable modem during this interval, only one 
             cdxCmtsCmOnOffNotification is sent by CMTS for the first 
             state change to online and one cdxCmtsCmOnOffNotification 
             for the first state changing to offline if 
             cdxCmtsCmOnOffTrapEnable is true.

             This is to avoid too many notifications sent for a cable 
             modem online/offline state changes during a short period
             of time. 

             If the value is 0, then cdxCmtsCmOnOffNotification will be 
             sent for every state changes to online/offline for a cable 
             modem if cdxCmtsCmOnOffTrapEnable is true.  

             If cdxCmtsCmOnOffTrapEnable value changes from true to false 
             or from false to true, this value will remain no change as 
             before. 

             The default value is 600 seconds. "
        ::= { cdxCmtsMacExtEntry 2 }

cdxCmtsCmDefaultMaxCpes OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The default maximum number of permitted CPEs per modem 
             in this cable interface. A modem can override this 
             value by setting the object cdxCmtsCmMaxCpeNumber
             in the cdxCmtsCmTable.  

             The value 0 means no maximum limit.

             Setting the value will not affect the already connected
             CPEs to the modems in this cable interface. "
        ::= { cdxCmtsMacExtEntry 3 }

cdxCmtsCmTotal OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total count of cable modems on this cable mac interface
             since boot."
        ::= { cdxCmtsMacExtEntry 4 }
           
cdxCmtsCmActive OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The count of cable modems that are active. Active cable 
             modems are recognized by the cdxCmtsCmStatusValue 
             other than offline(1). " 
        ::= { cdxCmtsMacExtEntry 5 }

cdxCmtsCmRegistered OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The count of cable modems that are registered and online 
             on this cable mac interface. Registered cable modems are 
             those with one of the following values. 
             registrationComplete(6) of docsIfCmtsCmStatusValue OR 
             either of online(12), kekRejected(10), 
             onlineKekAssigned(6),tekRejected(11), onlineTekAssigned(7)
             of cdxCmtsCmStatusValue"
        ::= { cdxCmtsMacExtEntry 6 }

--
-- CMTS Cable Modem channel override operation table and the related
-- objects 
--
-- A CMTS operator may perform downstream/upstream load balancing
-- or failure recovery using cdxCmtsCmChOverTable.  An entry 
-- in this table is an operation from CMTS to generates downstream 
-- frequency and upstream channel override fields in the RNG-RSP message 
-- sent to a cable modem.  A RNG-RSP message is sent to a cable modem 
-- during initial maintenance opportunity. 
--
-- This operation causes the uBR to place an entry for the cable 
-- modem specified into the override request queue.  The link is 
-- then broken by deleting the modem from its polling list.  When 
-- the modem attempts initial ranging, the override request 
-- causes downstream frequency and upstream channel override 
-- fields to be inserted into the RNG-RSP message.  
--

cdxCmtsCmChOverTimeExpiration OBJECT-TYPE
        SYNTAX      Integer32 (1..86400)
        UNITS       "minutes"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The time period to expire a CMTS channel override operation. 
             Within the time period, if the CMTS cannot send out a 
             RNG-RSP message with channel override fields to a cable 
             modem specified in the operation, the CMTS will abort 
             the operation. The possible reason is that the cable 
             modem does not repeat the initial ranging. 

             The change to this object will not affect the already active 
             operations in this cdxCmtsCmChOverTable.   
              
             Once the operation completes, the management station should
             retrieve the values of the cdxCmtsCmChOverState 
             object of interest, and should then delete the entry
             from cdxCmtsCmChOverTable.  In order to prevent old 
             entries from clogging the table, entries will be aged out, 
             but an entry will never be deleted within 15 minutes of 
             completing. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724),
             6.3.2.5.3 Overriding Channels. "
      ::= { cdxCmtsCmCpeObjects 4 }
 

cdxCmtsCmChOverTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmtsCmChOverEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A table of CMTS operation entries to instruct cable modems
            to move to a new downstream and/or upstream channel. 

            An entry in this table is an operation that has been 
            initiated from CMTS to generates downstream frequency and/or 
            upstream channel override fields in the RNG-RSP message sent 
            to a cable modem.  A RNG-RSP message is sent to a cable 
            modem during initial maintenance opportunity. 

            This operation causes the uBR to place an entry for the cable 
            modem specified into the override request queue.  The link is 
            then broken by deleting the modem from its polling list.  When 
            the modem attempts initial ranging, the override request 
            causes downstream frequency and upstream channel override 
            fields to be inserted into the RNG-RSP message.  "
      ::= { cdxCmtsCmCpeObjects 5 }

cdxCmtsCmChOverEntry OBJECT-TYPE
        SYNTAX      CdxCmtsCmChOverEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A CMTS operation entry to instruct a cable modem to move to
             a new downstream and/or upstream channel.
 
             A CMTS operator can use this to initiate an operation
             in CMTS to instruct a cable modem to move to a new
             downstream, or upstream channel or both. 
             
             Each entry consists of the mac address of the cable modem
             to be moved, a new downstream frequency, a new upstream channel 
             id etc..  More than one entries could have for a cable modem,
             so there is a time stamp for each entry to show the time
             when this operation is initiated. 

             A management station wishing to create an entry should
             first generate a pseudo-random serial number to be used
             as the index to this sparse table.  The station should
             then create the associated instance of the row status
             object. It must also, either in the same or in successive
             PDUs, create the associated instance of the command and
             parameter objects. It should also modify the default values
             for any of the parameter objects if the defaults are not
             appropriate.

             Once the appropriate instances of all the command
             objects have been created, either by an explicit SNMP
             set request or by default, the row status should be set
             to active to initiate the operation. Note that this entire
             procedure may be initiated via a single set request which
             specifies a row status  of createAndGo as well as specifies
             valid values for the non-defaulted parameter objects.

             Once an operation has been activated, it cannot be stopped.
             That is, it will run until either the CMTS has generated 
             downstream frequency and/or upstream channel override fields 
             in the RNG-RSP message sent to a cable modem or time out. 
             In either case, the operation is completed.

             Once the operation is completed, the real result of the 
             operation to the cable modem cannot be known from this table.
             The result of the cable modem's downstream frequency and the 
             upstream channel id can be checked from other MIB tables.  
             For example, docsIfCmtsServiceTable from DOCS-IF-MIB can be 
             used to check whether the cable modem's downstream frequency
             and upstream channel id are changed.  Please note that even
             the CMTS has generated downstream frequency and/or upstream 
             channel override fields in the RNG-RSP message sent to a 
             cable modems, if the cable modem cannot lock the instructed 
             downstream frequency or no upstream channel id could be used, 
             it may reconnect back to the original downstream frequency
             and upstream channel id. 
            
             Once the operation completes, the management station should
             retrieve the values of the cdxCmtsCmChOverState 
             objects of interest, and should then delete the entry.  
             In order to prevent old entries from clogging the table, 
             entries will be aged out, but an entry will never be deleted 
             within 15 minutes of completing. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724),
             6.3.2.5.3 Overriding Channels. "
        INDEX { cdxCmtsCmChOverSerialNumber }
        ::= { cdxCmtsCmChOverTable 1 }

CdxCmtsCmChOverEntry ::= SEQUENCE {
            -- index
            cdxCmtsCmChOverSerialNumber     Integer32,
            -- operation items
            cdxCmtsCmChOverMacAddress       MacAddress,  
            cdxCmtsCmChOverDownFrequency    Integer32,  
            cdxCmtsCmChOverUpChannelId      Integer32, 
            cdxCmtsCmChOverTrapOnCompletion TruthValue,
            -- status items
            cdxCmtsCmChOverOpInitiatedTime  TimeStamp,
            cdxCmtsCmChOverState            INTEGER,
            cdxCmtsCmChOverRowStatus        RowStatus
        } 

cdxCmtsCmChOverSerialNumber OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
            "Object which specifies a unique entry in the
             table. A management station wishing to initiate a
             channel override operation should use a pseudo-random 
             value for this object when creating or modifying an 
             instance of a cdxCmtsCmChOverEntry.  "
        ::= { cdxCmtsCmChOverEntry 1 }

cdxCmtsCmChOverMacAddress OBJECT-TYPE
        SYNTAX     MacAddress
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "The mac address of the cable modem that the CMTS instructs to
             move to a new downstream and/or upstream channel.  

             This column must be set to a valid Mac address currently in
             the CMTS in order for this entry's row status to be set to
             active successfully." 
        ::= { cdxCmtsCmChOverEntry 2 }
        
cdxCmtsCmChOverDownFrequency  OBJECT-TYPE
        SYNTAX     Integer32 (0..1000000000)
        UNITS      "hertz"
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "The new downstream frequency which the cable modem is 
             instructed to move to.  The value 0 is to ask the CMTS not to
             override the downstream frequency. "  
        DEFVAL { 0 }
        ::= { cdxCmtsCmChOverEntry 3 }

cdxCmtsCmChOverUpChannelId  OBJECT-TYPE
        SYNTAX     Integer32 (-1..255)
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "The new channel Id which the cable modem is instructed to 
             move to.  The value -1 is to ask the CMTS not to override
             the upstream channel Id. "
        DEFVAL { -1 }
        ::= { cdxCmtsCmChOverEntry 4 }

cdxCmtsCmChOverTrapOnCompletion OBJECT-TYPE
        SYNTAX     TruthValue
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "Specifies whether or not a cdxCmtsCmChOverNotification 
             should be issued on completion of the operation.  If such a 
             notification is desired, it is the responsibility of the 
             management entity to ensure that the SNMP administrative model 
             is configured in such a way as to allow the notification to be 
             delivered. "
        DEFVAL { false }
        ::= { cdxCmtsCmChOverEntry 5 }

cdxCmtsCmChOverOpInitiatedTime OBJECT-TYPE
        SYNTAX     TimeStamp
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
            "The value of sysUpTime at which the operation was initiated.  
             Since it is possible to have more than one entry in this 
             table for a cable modem, this object can help to distinguish 
             the entries for the same cable modem. " 
        ::= { cdxCmtsCmChOverEntry 6 }

cdxCmtsCmChOverState  OBJECT-TYPE
        SYNTAX     INTEGER {
            messageSent(1),
            commandNotActive(2),
            noOpNeeded(3),
            modemNotFound(4),
            waitToSendMessage(5),    
            timeOut(6)   
        }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
            "The status of the specified channel override operation.
             The enumerations are:
               messageSent(1): the CMTS has sent a RNG-RSP message 
                           with channel override to the cable modem. 
               commandNotActive(2): the command is not in active mode
                                    due to this entry's row status is not
                                    in active yet.
               noOpNeed(3): The downstream frequency and the upstream 
                            channel Id in this entry are the same as 
                            original ones when this entry's row status
                            is set to active, so CMTS does not need to 
                            do any operation.  
               modemNotFound(4): The modem is not found in the CMTS
                                 at the time when the command becomes
                                 active.
               waitToSendMessage(5): specified the operation is active
                                     and CMTS is waiting to send
                                     a RNG-RSP message with channel 
                                     override to the cable modem.
               timeOut(6): specified the operation is timed out.
                           That is, the CMTS cannot send a RNG-RSP message 
                           with channel override to the cable modem within 
                           the time specified in the object of 
                           cdxCmtsCmChOverTimeExpiration. 
                           The possible reason is that the cable modem
                           does not repeat the initial ranging. 

                The possible state change diagram is as below: 
                [commandNotActive ->] waitToSendMessage -> 
                    messageSent or timeOut. 
                [commandNotActive ->] noOpNeeded or modemNotFound. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724),
             6.3.2.5.3 Overriding Channels. "
        ::= { cdxCmtsCmChOverEntry 7 }

cdxCmtsCmChOverRowStatus OBJECT-TYPE
        SYNTAX     RowStatus
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "The status of this table entry.  

             This value for cdxCmtsCmChOverMacAddress must be valid Mac 
             address currently in the CMTS in order for the row 
             status to be set to active successfully. 
                
             Once the row status becomes active and state becomes 
             waitToSendMessage, the entry cannot not be changed except 
             to delete the entry by setting the row status to destroy(6) 
             and since the operation cannot be stopped, the destroy(6) 
             will just cause the SNMP agent to hide the entry from 
             application and the SNMP agent will delete the entry 
             right after the operation is completed. "
        ::= { cdxCmtsCmChOverEntry 8 }

--
-- CMTS Cable modem (CM) Table
--
-- This table contains attributes or configurable parameters 
-- for cable modems from a CMTS.   
--
-- A CMTS operator can use this table to report a cable modem's  
-- attributes or configure a cable modem by a cable modem's 
-- MAC address.
--

cdxCmtsCmTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF CdxCmtsCmEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This table contains attributes or configurable parameters 
            for cable modems from a CMTS. " 
       ::= { cdxCmtsCmCpeObjects 6 }

cdxCmtsCmEntry OBJECT-TYPE
        SYNTAX      CdxCmtsCmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
           "The list contains a cable modem's attributes or 
            configurable parameters from a CMTS. "
        INDEX { docsIfCmtsCmStatusIndex }
        ::= { cdxCmtsCmTable 1 } 

CdxCmtsCmEntry ::= SEQUENCE {
            cdxCmtsCmMaxCpeNumber     Integer32,
            cdxCmtsCmCurrCpeNumber    Integer32
        }

cdxCmtsCmMaxCpeNumber OBJECT-TYPE
        SYNTAX      Integer32 (-1..255)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum number of permitted CPEs connecting to the
             modem. 

             The value -1 means to use the default value of maximum 
             hosts per modem in the CMTS cable interface which the modem 
             connects to and the value is defined in 
             cdxCmtsCmDefaultMaxCpes in the cdxCmtsMacExtTable. 

             The value 0 means no maximum limit.

             Setting the value will not affect the already connected
             CPEs to the modem. "
        ::= { cdxCmtsCmEntry 1 }

cdxCmtsCmCurrCpeNumber OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current number of CPEs connecting to the modem.

             The value 0 means no hosts connecting to the modem."
 
        ::= { cdxCmtsCmEntry 2 }

--
-- CMTS Upstream Group
--
-- Upstream impairment mitigation techniques are crucial to enhancing 
-- the communications reliability of two-way HFC cable plants. The
-- hardware and software based capabilities built in to the CMTS assist
-- in automatic noise mitigation.
-- 
-- This group contains tables in CMTS for configuring the upstream
-- channel attributes for automated Spectrum Management.
--
-- In addition the group also has the count of cable modems on this 
-- upstream. Separate counts are used to represent the number of active,
-- registered and total number cable modems on this upstream .

--
-- CMTS Upstream Channel Table 
--
-- This table contains the additional upstream channel attributes .
-- The additional configurable objects for automated Spectrum Management
-- are the modulation profile and channel width needed for the frequency 
-- hop algorithm used for noise mitigation. 
--
-- Another upstream channel attribute is the number of cable modems.
-- There are three objects to represent each of the following counts:
-- Total: # of modems that were seen on this upstream since boot 
-- Active: # of modems that are active(not online or reset).
-- Registered: # of modems that are registered and online.
--
-- The upstream input power attribute is also reported in the table.

cdxIfUpstreamChannelExtTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CdxIfUpstreamChannelExtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table contains upstream channel attributes for  
             automated Spectrum management, in addition to the ones
             provided by docsIfUpstreamChannelEntry.
             It also contains upstream channel attributes to count 
             the number of active,registered and total number of cable 
             modems on this upstream. "
        ::= { cdxSpecMgmtObjects 1 }

cdxIfUpstreamChannelExtEntry OBJECT-TYPE
        SYNTAX      CdxIfUpstreamChannelExtEntry 
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Additional objects for docsIfUpstreamChannelEntry,including 
             the secondary upstream channel modulation profile,the 
             lower bound for the channel width and the number of active,
             registered and total number of cable modems on this 
             upstream channel. "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications (DOCSIS)
             Radio Frequency Interface Specification (SP-RFI-I04-980724.)
             docsIfUpstreamChannelTable in DOCS-IF-MIB.my. "
        AUGMENTS { docsIfUpstreamChannelEntry }
        ::= { cdxIfUpstreamChannelExtTable 1 }

CdxIfUpstreamChannelExtEntry ::= SEQUENCE {
            cdxIfUpChannelWidth                  Integer32,
            cdxIfUpChannelModulationProfile      Unsigned32,
            cdxIfUpChannelCmTotal                Integer32,
            cdxIfUpChannelCmActive               Integer32,
            cdxIfUpChannelCmRegistered           Integer32,
            cdxIfUpChannelInputPowerLevel        TenthdBmV,
            cdxIfUpChannelAvgUtil                Integer32,
            cdxIfUpChannelAvgContSlots           Integer32,
            cdxIfUpChannelRangeSlots             Integer32,
            cdxIfUpChannelNumActiveUGS           Unsigned32,
            cdxIfUpChannelMaxUGSLastOneHour      Unsigned32,
            cdxIfUpChannelMinUGSLastOneHour      Unsigned32,
            cdxIfUpChannelAvgUGSLastOneHour      Unsigned32,
            cdxIfUpChannelMaxUGSLastFiveMins     Unsigned32,
            cdxIfUpChannelMinUGSLastFiveMins     Unsigned32,
            cdxIfUpChannelAvgUGSLastFiveMins     Unsigned32
        }

cdxIfUpChannelWidth OBJECT-TYPE
        SYNTAX      Integer32(0..16000000)
        UNITS       "hertz"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The lower bound for the bandwidth of this upstream channel. 
             The bandwidth specified by docsIfUpChannelWidth is used as
             the upper bound of the upstream channel. The two objects,
             docsIfUpChannelWidth and cdxIfUpChannelWidth, in 
             conjunction, define the upstream channel width range to be
             used for the automated spectrum management.

             This object returns 0 if the channel width is undefined 
             or unknown.

             For those upstreams in the linecards which do not have the
             automated spectrum management feature, this channel width
             is undefined and always has value 0. " 
        ::= { cdxIfUpstreamChannelExtEntry 1 }

cdxIfUpChannelModulationProfile OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The secondary modulation profile for the upstream channel.
             This should be a QPSK modulation profile if the primary profile 
             is QAM-16. The CMTS will switch from primary profile (QAM16) to 
             secondary profile (QPSK) depending on the noise level of a 
             particular spectrum band.

             This is an entry identical to the docsIfModIndex in the 
             docsIfCmtsModulationTable that describes this channel.
             This channel is further instantiated there by a grouping
             of interval usage codes which together fully describe the
             channel modulation. This object returns 0 if the
             docsIfCmtsModulationTable does not exist or is empty. "
        ::= { cdxIfUpstreamChannelExtEntry 2 }

cdxIfUpChannelCmTotal OBJECT-TYPE
        SYNTAX      Integer32 (0..8191)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total count of cable modems on this upstream channel
             since boot."
        ::= { cdxIfUpstreamChannelExtEntry 3 }

cdxIfUpChannelCmActive OBJECT-TYPE
        SYNTAX      Integer32 (0..8191)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The count of cable modems that are active.Active cable 
             modems are recognized by the cdxCmtsCmStatusValue other  
             than offline(1). " 
        ::= { cdxIfUpstreamChannelExtEntry 4 }

cdxIfUpChannelCmRegistered OBJECT-TYPE
        SYNTAX      Integer32 (0..8191)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The count of cable modems that are registered and online
             on this upstream. Registered cable modems are those
             with one of the following values:
             registrationComplete(6) of docsIfCmtsCmStatusValue OR
             online(12), kekRejected(10), onlineKekAssigned(6),
             tekRejected(11),onlineTekAssigned(7) of 
             cdxCmtsCmStatusValue."
        ::= { cdxIfUpstreamChannelExtEntry 5 }

cdxIfUpChannelInputPowerLevel OBJECT-TYPE
        SYNTAX      TenthdBmV (-100..250)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The Upstream Input power level at the CMTS interface.
             This is the expected power level and is different from the
             actual power received. If not configured the default value
             is 0 dBmV and is also the optimum setting power level for
             the upstream. For FPGA line cards, the valid range
             is <-10 to 10> dBmV and for ASIC Line cards, it is 
             <-10  to 25> dBmV. " 
        ::= { cdxIfUpstreamChannelExtEntry 6 }

cdxIfUpChannelAvgUtil OBJECT-TYPE
        SYNTAX      Integer32 (0..100)
        UNITS       "percent"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average percentage of upstream channel utilization. 
             This item indicates the running average of percent
             channel utilization in CMTS upstream Mac scheduler. "
        ::= { cdxIfUpstreamChannelExtEntry 7 }

cdxIfUpChannelAvgContSlots OBJECT-TYPE
        SYNTAX      Integer32 (0..100)
        UNITS       "percent"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average percentage of contention mini-slots. This
             item indicates the running average of percent
             contention mini-slots in CMTS upstream Mac scheduler. "
        ::= { cdxIfUpstreamChannelExtEntry 8 }

cdxIfUpChannelRangeSlots OBJECT-TYPE
        SYNTAX      Integer32 (0..100)
        UNITS       "percent"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average percentage of initial ranging mini-slots. 
             This item indicates the running average of percent
             initial ranging mini-slots in CMTS upstream Mac
             scheduler. "
        ::= { cdxIfUpstreamChannelExtEntry 9 }

cdxIfUpChannelNumActiveUGS OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the number of active 
             Unsolicited Grant Service (UGS) on a given upstream.
             This would be used for the user to evaluate traffic 
             load at any given time of the day.

             The Unsolicited Grant Service (UGS) is designed to 
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 10 }

cdxIfUpChannelMaxUGSLastOneHour OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the maximum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 11 }

cdxIfUpChannelMinUGSLastOneHour OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the minimum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 12 }

cdxIfUpChannelAvgUGSLastOneHour OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the average number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 13 }

cdxIfUpChannelMaxUGSLastFiveMins OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the maximum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 14 }

cdxIfUpChannelMinUGSLastFiveMins OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the minimum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 15 }

cdxIfUpChannelAvgUGSLastFiveMins OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object indicates the average number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day.

             The Unsolicited Grant Service (UGS) is designed to
             support real-time service flows that generate fixed
             size data packets on a periodic basis. "
        ::= { cdxIfUpstreamChannelExtEntry 16 }
        
--
-- The Cisco DOCS Extension MIB Notifications 
--

ciscoDocsExtNotificationsPrefix   OBJECT IDENTIFIER
                          ::= { ciscoDocsExtMIB 2 }
ciscoDocsExtNotifications         OBJECT IDENTIFIER
                          ::= { ciscoDocsExtNotificationsPrefix 0 }


cdxCmtsCmOnOffNotification NOTIFICATION-TYPE
       OBJECTS    { docsIfCmtsCmStatusMacAddress,
                    docsIfCmtsCmStatusIpAddress,
                    docsIfCmtsCmStatusDownChannelIfIndex,
                    docsIfCmtsCmStatusUpChannelIfIndex,
                    cdxCmCpeCmtsServiceId,
                    cdxCmtsCmStatusValue 
                  }
       STATUS  current
       DESCRIPTION
           "This notification indicates that the cable modem coming online
            and going offline. A notification will be sent from CMTS for 
            a cable modem status changing to online or offline
            within the interval specified in cdxCmtsCmOnOffTrapInterval. "
       ::= { ciscoDocsExtNotifications 1 }


cdxCmtsCmChOverNotification NOTIFICATION-TYPE
       OBJECTS    { cdxCmtsCmChOverMacAddress,
                    cdxCmtsCmChOverDownFrequency,
                    cdxCmtsCmChOverUpChannelId,
                    cdxCmtsCmChOverOpInitiatedTime,
                    cdxCmtsCmChOverState
                  }
       STATUS  current
       DESCRIPTION
           "This notification is sent at the completion of a CMTS 
            channel override operation if 
            cdxCmtsCmChOverTrapOnCompletion is true in the
            original entry.

            Once a channel override operation has been activated, it 
            cannot be stopped.  That is, it will run until either the 
            CMTS has generated downstream frequency and/or upstream 
            channel override fields in the RNG-RSP message sent to a 
            cable modem or 
            cdxCmtsCmChOverTimeExpiration time expired.
            In either case, the operation is completed. State in the 
            cdxCmtsCmChOverState object will tell in which 
            condition the operation is completed. "
       ::= { ciscoDocsExtNotifications 2 }




--
-- The Cisco DOCS Extension MIB Conformance Statements 
--

--
-- Conformance statement
--

ciscoDocsExtConformance  OBJECT IDENTIFIER 
    ::= { ciscoDocsExtMIB 3 }
cdxDocsExtCompliances               OBJECT IDENTIFIER 
    ::= { ciscoDocsExtConformance 1 }
cdxDocsExtGroups                    OBJECT IDENTIFIER 
    ::= { ciscoDocsExtConformance 2 }


-- compliance statements

cdxDocsExtCompliance MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev1 
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroup, 
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 1 }


cdxDocsExtComplianceRev1 MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev2 
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev1,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev1,
                        cdxSpecMgmtGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 2 }

cdxDocsExtComplianceRev2 MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev3 
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS 
             features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev1,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev2,
                        cdxSpecMgmtGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 3 }

cdxDocsExtComplianceRev3 MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev4
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS
             features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev1,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev3,
                        cdxSpecMgmtGroupRev1
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 4 }
        
cdxDocsExtComplianceRev4 MODULE-COMPLIANCE
        STATUS    obsolete 
--                superseded by current cdxDocsExtComplianceRev5
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS
             features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev2,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev4,
                        cdxSpecMgmtGroupRev1
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 5 }

cdxDocsExtComplianceRev5 MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev6
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS
             features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev2,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev4,
                        cdxSpecMgmtGroupRev2,
                        cdxNotifGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 6 }

cdxDocsExtComplianceRev6 MODULE-COMPLIANCE
        STATUS    obsolete -- superseded by cdxDocsExtComplianceRev7
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS
             features."
        MODULE  -- this module
        	MANDATORY-GROUPS {
        	        cdxQosCtrlGroupRev2,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev4,
                        cdxSpecMgmtGroupRev3,
                        cdxNotifGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 7 }

cdxDocsExtComplianceRev7 MODULE-COMPLIANCE
        STATUS    current
        DESCRIPTION
            "The compliance statement for devices that implement MCNS
             compliant Radio Frequency Interfaces and DOCSIS
             features."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        cdxQosCtrlGroupRev2,
                        cdxQosQueueGroup,
                        cdxCmtsCmCpeGroupRev5,
                        cdxSpecMgmtGroupRev3,
                        cdxNotifGroup
                }

        OBJECT     cdxCmtsCmChOverTimeExpiration
        MIN-ACCESS read-only
        DESCRIPTION
                   "Write access is not required."
        ::= { cdxDocsExtCompliances 8 }

-- MIB groupings

cdxQosCtrlGroup OBJECT-GROUP
        OBJECTS {
        cdxQosCtrlUpAdmissionCtrl,
        cdxQosCtrlUpMaxRsvdBWPercent,
        cdxQosCtrlUpAdmissionRejects,
        cdxQosCtrlUpReservedBW,
        cdxQosCtrlUpMaxVirtualBW,
        cdxQosIfRateLimitAlgm,
        cdxQosIfRateLimitExpWt,
        cdxIfCmtsServiceOutOctets,
        cdxIfCmtsServiceOutPackets,
        cdxQosMaxUpBWExcessRequests,
        cdxQosMaxDownBWExcessPackets
        }
        STATUS    obsolete -- superseded by cdxQosCtrlGroupRev1 
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) cable interfaces for states of the scheduler supporting 
             Data-Over-Cable Service Interface Specifications (DOCSIS)
             1.0 Quality of Service (QoS). "
        ::= { cdxDocsExtGroups 1 }


cdxQosQueueGroup OBJECT-GROUP
        OBJECTS {
        cdxBWQueueOrder,
        cdxBWQueueNumServedBeforeYield,
        cdxBWQueueType,
        cdxBWQueueMaxDepth,
        cdxBWQueueDepth,
        cdxBWQueueDiscards
        }
        STATUS    current
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) cable interfaces for the queuing states of the scheduler 
             supporting Data-Over-Cable Service Interface Specifications 
             (DOCSIS) Quality of Service (QoS). Each upstream scheduler 
             maintains a queue set, but the downstream schedulers does not 
             in DOCSIS QoS. So only each upstream has an entry for 
             DOCSIS QoS support."
        ::= { cdxDocsExtGroups 2 }

cdxCmtsCmCpeGroup OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIpAddress,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber
        }
        STATUS    obsolete -- superseded by cdxCmtsCmCpeGroupRev1 
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) for managing and monitoring cable modems or Customer 
             Premises Equipments. "
        ::= { cdxDocsExtGroups 3 }

cdxQosCtrlGroupRev1 OBJECT-GROUP
        OBJECTS {
        cdxQosCtrlUpAdmissionCtrl,
        cdxQosCtrlUpMaxRsvdBWPercent,
        cdxQosCtrlUpAdmissionRejects,
        cdxQosCtrlUpReservedBW,
        cdxQosCtrlUpMaxVirtualBW,
        cdxQosIfRateLimitAlgm,
        cdxQosIfRateLimitExpWt,
        cdxQosIfRateLimitShpGranularity,
        cdxQosIfRateLimitShpMaxDelay,
        cdxIfCmtsServiceOutOctets,
        cdxIfCmtsServiceOutPackets,
        cdxQosMaxUpBWExcessRequests,
        cdxQosMaxDownBWExcessPackets
        }
        STATUS    obsolete -- superseded by cdxQosCtrlGroupRev2
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) cable interfaces for states of the scheduler supporting 
             Data-Over-Cable Service Interface Specifications (DOCSIS)
             Quality of Service (QoS). "
        ::= { cdxDocsExtGroups 4 }

        
cdxCmtsCmCpeGroupRev1 OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIpAddress,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxIfCmtsCmStatusDynSidCount,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber
        }
        STATUS    obsolete -- superseded by cdxCmtsCmCpeGroupRev2 
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) for managing and monitoring cable modems or Customer 
             Premises Equipments. "
        ::= { cdxDocsExtGroups 5 }

cdxSpecMgmtGroup OBJECT-GROUP
        OBJECTS {
        cdxIfUpChannelWidth,
        cdxIfUpChannelModulationProfile
        }
        STATUS    obsolete --  superseded by cdxSpecMgmtGroupRev1
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination Systems 
             (CMTS) cable interfaces for automated upstream spectrum 
             management. "
        ::= { cdxDocsExtGroups 6 }


cdxCmtsCmCpeGroupRev2 OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIpAddress,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmCpeResetNow, 
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxIfCmtsCmStatusDynSidCount,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber,
        cdxCmtsCmCurrCpeNumber
        }
        STATUS    obsolete -- superseded by cdxCmtsCmCpeGroupRev3 
        DESCRIPTION
            "Group of objects implemented in Cable Modem 
             Termination Systems (CMTS) for managing and monitoring 
             cable modems or Customer Premises Equipments. "
        ::= { cdxDocsExtGroups 7 }


cdxSpecMgmtGroupRev1 OBJECT-GROUP
        OBJECTS {
        cdxIfUpChannelWidth,
        cdxIfUpChannelModulationProfile,
        cdxIfUpChannelCmTotal,
        cdxIfUpChannelCmActive,
        cdxIfUpChannelCmRegistered
        }
        STATUS    obsolete -- superseeded by cdxSpecMgmtGroupRev2 
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination 
             Systems (CMTS) cable interfaces for automated upstream 
             spectrum management. "
        ::= { cdxDocsExtGroups 8 }

                                                                        
cdxCmtsCmCpeGroupRev3 OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIpAddress,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmCpeResetNow, 
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxIfCmtsCmStatusDynSidCount,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmTotal,
        cdxCmtsCmActive,
        cdxCmtsCmRegistered,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber,
        cdxCmtsCmCurrCpeNumber
        }
        STATUS    obsolete -- superseded by  cdxCmtsCmCpeGroupRev4
        DESCRIPTION
            "Group of objects implemented in Cable Modem 
             Termination Systems (CMTS) for managing and monitoring 
             cable modems or Customer Premises Equipments. "
        ::= { cdxDocsExtGroups 9 }
        
cdxQosCtrlGroupRev2 OBJECT-GROUP
        OBJECTS {
        cdxQosCtrlUpAdmissionCtrl,
        cdxQosCtrlUpMaxRsvdBWPercent,
        cdxQosCtrlUpAdmissionRejects,
        cdxQosCtrlUpReservedBW,
        cdxQosCtrlUpMaxVirtualBW,
        cdxQosIfRateLimitAlgm,
        cdxQosIfRateLimitExpWt,
        cdxQosIfRateLimitShpGranularity,
        cdxQosIfRateLimitShpMaxDelay,
        cdxIfCmtsServiceOutOctets,
        cdxIfCmtsServiceOutPackets,
        cdxQosMaxUpBWExcessRequests,
        cdxQosMaxDownBWExcessPackets,
        cdxUpInfoElemStatsIEType             
        }
        STATUS    current
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination 
            Systems (CMTS) cable interfaces for states of the scheduler
            supporting Data-Over-Cable Service Interface Specifications
            (DOCSIS) Quality of Service (QoS).Statistics about the IE 
            types in the Upstream channel. "
        ::= { cdxDocsExtGroups 10 }
        
cdxCmtsCmCpeGroupRev4 OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIpAddress,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmCpeResetNow, 
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxIfCmtsCmStatusDynSidCount,
        cdxIfCmtsCmStatusAddlInfo,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmTotal,
        cdxCmtsCmActive,
        cdxCmtsCmRegistered,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber,
        cdxCmtsCmCurrCpeNumber
        }
        STATUS    obsolete -- superseded by cdxCmtsCmCpeGroupRev5 
        DESCRIPTION
            "Group of objects implemented in Cable Modem 
             Termination Systems (CMTS) for managing and monitoring 
             cable modems or Customer Premises Equipments. "
        ::= { cdxDocsExtGroups 11 }

cdxSpecMgmtGroupRev2 OBJECT-GROUP
        OBJECTS {
        cdxIfUpChannelWidth,
        cdxIfUpChannelModulationProfile,
        cdxIfUpChannelCmTotal,
        cdxIfUpChannelCmActive,
        cdxIfUpChannelCmRegistered,
        cdxIfUpChannelInputPowerLevel
        }
        STATUS    obsolete -- superseded by cdxSpecMgmtGroupRev3
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination
             Systems (CMTS) for upstream interfaces. "
        ::= { cdxDocsExtGroups 12 }


cdxNotifGroup    NOTIFICATION-GROUP
        NOTIFICATIONS {
        cdxCmtsCmOnOffNotification,
        cdxCmtsCmChOverNotification
        } 
                       
        STATUS  current
        DESCRIPTION
            "A group of notifications implemented in Cable Modem 
             Termination Systems (CMTS) for managing and monitoring
             cable modems or Customer Premises Equipments. "
        ::= { cdxDocsExtGroups 13 }

cdxSpecMgmtGroupRev3 OBJECT-GROUP
        OBJECTS {
        cdxIfUpChannelWidth,
        cdxIfUpChannelModulationProfile,
        cdxIfUpChannelCmTotal,
        cdxIfUpChannelCmActive,
        cdxIfUpChannelCmRegistered,
        cdxIfUpChannelInputPowerLevel,
        cdxIfUpChannelAvgUtil,
        cdxIfUpChannelAvgContSlots,
        cdxIfUpChannelRangeSlots,
        cdxIfUpChannelNumActiveUGS,
        cdxIfUpChannelMaxUGSLastOneHour,
        cdxIfUpChannelMinUGSLastOneHour,
        cdxIfUpChannelAvgUGSLastOneHour,
        cdxIfUpChannelMaxUGSLastFiveMins,
        cdxIfUpChannelMinUGSLastFiveMins,
        cdxIfUpChannelAvgUGSLastFiveMins
        }
        STATUS    current
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination
             Systems (CMTS) for upstream interfaces. "
        ::= { cdxDocsExtGroups 14 }

cdxCmtsCmCpeGroupRev5 OBJECT-GROUP
        OBJECTS {
        cdxCmCpeType,
        cdxCmCpeIfIndex,
        cdxCmCpeCmtsServiceId,
        cdxCmCpeCmStatusIndex,
        cdxCmCpeAccessGroup,
        cdxCmCpeResetNow,
        cdxCmtsCmStatusValue,
        cdxIfCmtsCmStatusOnlineTimes,
        cdxIfCmtsCmStatusPercentOnline,
        cdxIfCmtsCmStatusMinOnlineTime,
        cdxIfCmtsCmStatusAvgOnlineTime,
        cdxIfCmtsCmStatusMaxOnlineTime,
        cdxIfCmtsCmStatusMinOfflineTime,
        cdxIfCmtsCmStatusAvgOfflineTime,
        cdxIfCmtsCmStatusMaxOfflineTime,
        cdxIfCmtsCmStatusDynSidCount,
        cdxIfCmtsCmStatusAddlInfo,
        cdxCmtsCmOnOffTrapEnable,
        cdxCmtsCmOnOffTrapInterval,
        cdxCmtsCmDefaultMaxCpes,
        cdxCmtsCmTotal,
        cdxCmtsCmActive,
        cdxCmtsCmRegistered,
        cdxCmtsCmChOverTimeExpiration,
        cdxCmtsCmChOverMacAddress,
        cdxCmtsCmChOverDownFrequency,
        cdxCmtsCmChOverUpChannelId,
        cdxCmtsCmChOverTrapOnCompletion,
        cdxCmtsCmChOverOpInitiatedTime,
        cdxCmtsCmChOverState,
        cdxCmtsCmChOverRowStatus,
        cdxCmtsCmMaxCpeNumber,
        cdxCmtsCmCurrCpeNumber,
        cdxIfCmtsCmStatusOnlineTimesNum,
        cdxIfCmtsCmStatusLastResetTime
        }
        STATUS    current
        DESCRIPTION
            "Group of objects implemented in Cable Modem
             Termination Systems (CMTS) for managing and monitoring
             cable modems or Customer Premises Equipments. "
        ::= { cdxDocsExtGroups 15 }


END