CISCO-ENTITY-PFE-MIB device MIB details by Cisco
CISCO-ENTITY-PFE-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-ENTITY-PFE-MIB.
Vendor: | Cisco |
---|---|
Mib: | CISCO-ENTITY-PFE-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- ****************************************************************** -- CISCO-ENTITY-PFE-MIB -- -- This module is used for maintaining the performance history for -- Packet Forwarding Engine(PFE) processors. -- -- Aug 2002, Jaime Colom -- -- Copyright (c) 2002 by Cisco Systems, Inc. -- All rights reserved. -- ****************************************************************** -- CISCO-ENTITY-PFE-MIB DEFINITIONS ::= BEGIN IMPORTS Unsigned32, Gauge32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, DisplayString, TimeStamp FROM SNMPv2-TC entPhysicalIndex, PhysicalIndex FROM ENTITY-MIB ciscoMgmt FROM CISCO-SMI; ciscoEntityPfeMib MODULE-IDENTITY LAST-UPDATED "200211271600Z" ORGANIZATION "Cisco System, Inc." CONTACT-INFO "Postal: Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com" DESCRIPTION "The Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performance. An agent uses this MIB to monitor the performance history on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737) entPhysicalTable. This monitoring is via measurement periods of actual, 1-minute, 5-minutes and 15-minutes. For the 1-minute and 5-minute measurement periods, perfor- mance statistics are calculated and displayed based on pre- vious 1 minute and 5 minute respectively. For the 15-minute period, the performance statistics are accumulated in fifteen minute intervals. At any one time, an agent maintains one current (incomplete) interval and up to 96 completed intervals (24 hours worth). Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance statistic. There is no requirement for an agent to ensure fixed rela- tionship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours." REVISION "200211271600Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 265 } CurrentUtilization ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represent the actual utilization performance measurement." SYNTAX Gauge32 (0..100) CurrentEfficiency ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represents the actual efficiency performance measurement." SYNTAX Gauge32 (0..100) IntervalUtilization ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represents the utilization perfor- mance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchObject error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalUtilization(1) and IntervalUtilization(n) the most and least recent intervals respectively, the following proce- dure is used to update the intervals at end of a 15 minute interval: - discard the value of IntervalUtilization(n) - the value of IntervalUtilization(i) becomes that of IntervalUtilization(i-1) for n >= i > 1 - the value of IntervalUtilization(1) becomes that of current 15-minute %utilization." SYNTAX Gauge32 (0..100) IntervalEfficiency ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represents the efficiency performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchObject error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalEfficiency(1) and IntervalEfficiency(n) the most and least recent intervals respectively, the following procedure is used to update the intervals at end of a 15 minute inter- val: - discard the value of IntervalEfficiency(n) - the value of IntervalEfficiency(i) becomes that of IntervalEfficiency(i-1) for n >= i > 1 - the value of IntervalEfficiency(1) becomes that of currente 15-minute %efficiency." SYNTAX Gauge32 (0..100) TotalUtilization ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represents the total running utili- zation performance measurements." SYNTAX Gauge32 (0..100) TotalEfficiency ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value that represents the total running Effi- ciency performance measurements." SYNTAX Gauge32 (0..100) Percentage ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A percentage value." SYNTAX Unsigned32 (0..100) EventType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of action to execute when an event occurs. 'none' Neither log an entry in the cePfeHistTable, nor sent out an SNMP notification. 'log' Create a cePfeHistTable entry, but do not sent out an SNMP notification. 'notify' Sent out an SNMP notification, but do not create a log entry in the cePfeHistTable. 'logAndNotify' Both create a log entry in the cePfeHistTable and sent out an SNMP notification." SYNTAX INTEGER { none(1), log(2), notify(3), logAndNotify(4) } HistEventType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of event that has occurred. 'thldUtilizationEvent' This event is generated if the cePfePerfCurrentUtilization, at the time of sampling, becomes greater than or equal to the cePfePerfThldUtilization. 'thldEfficiencyEvent' This event is generated if the cePfePerfCurrentEfficiency, at the time of sampling, becomes less than or equal to the cePfePerfThldEfficiency. 'thld1MinUtilizationEvent' This event is generated if the cePfePerfCurrent1MinUtilization, at the time of sampling, becomes greater than or equal to the cePfePerfThld1MinUtilization. 'thld1MinEfficiencyEvent' This event is generated if the cePfePerfCurrent1MinEfficiency, at the time of sampling, becomes less than or equal to the cePfePerfThld1MinEfficiency. 'thld5MinUtilizationEvent' This event is generated if the cePfePerfCurrent5MinUtilization, at the time of sampling, becomes greater than or equal to the cePfePerfThld5MinUtilization. 'thld5MinEfficiencyEvent' This event is generated if the cePfePerfCurrent5MinEfficiency, at the time of sampling, becomes less than or equal to the cePfePerfThld5MinEfficiency. 'restartEvent' This event is generated every time the processor gets restarted." SYNTAX INTEGER { thldUtilizationEvent(1), thldEfficiencyEvent(2), thld1MinUtilizationEvent(3), thld1MinEfficiencyEvent(4), thld5MinUtilizationEvent(5), thld5MinEfficiencyEvent(6), restartEvent(7) } cePfeMIBNotifications OBJECT IDENTIFIER ::= { ciscoEntityPfeMib 0 } cePfeMIBObjects OBJECT IDENTIFIER ::= { ciscoEntityPfeMib 1 } cePfeMIBConformance OBJECT IDENTIFIER ::= { ciscoEntityPfeMib 2 } -- MIB Object Definitions cePfePerformance OBJECT IDENTIFIER ::= { cePfeMIBObjects 1 } cePfeHistory OBJECT IDENTIFIER ::= { cePfeMIBObjects 2 } cePfePerfConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CePfePerfConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains configuration information on a PFE pipeline." ::= { cePfePerformance 1 } cePfePerfConfigEntry OBJECT-TYPE SYNTAX CePfePerfConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry will exist for each entry in the entPhysicalTable that correspond to an active PFE pipeline." INDEX { entPhysicalIndex } ::= { cePfePerfConfigTable 1 } CePfePerfConfigEntry ::= SEQUENCE { cePfePerfConfigTimeElapsed Unsigned32, cePfePerfConfigValidIntervals Unsigned32, cePfePerfConfigThldUtilization Percentage, cePfePerfConfigThldEfficiency Percentage, cePfePerfConfigThld1MinUtilization Percentage, cePfePerfConfigThld1MinEfficiency Percentage, cePfePerfConfigThld5MinUtilization Percentage, cePfePerfConfigThld5MinEfficiency Percentage } cePfePerfConfigTimeElapsed OBJECT-TYPE SYNTAX Unsigned32 (0..899) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { cePfePerfConfigEntry 1 } cePfePerfConfigValidIntervals OBJECT-TYPE SYNTAX Unsigned32 (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of completed 15 min intervals for which valid PFE performance data has been collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of completed 15 minute intervals since the PFE pipeline has been online." ::= { cePfePerfConfigEntry 2 } cePfePerfConfigThldUtilization OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtilization object becomes greater than or equal to this threshold value, an event of type 'thldUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentUtilization object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 3 } cePfePerfConfigThldEfficiency OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficiency object becomes less than or equal to this threshold value, an event of type 'thldEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrentEfficiency object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 4 } cePfePerfConfigThld1MinUtilization OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thld1MinUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent1MinUtilization object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 5 } cePfePerfConfigThld1MinEfficiency OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrent1MinEfficiency object. If during the last 1 minute measurement period the cePfePerfCurrent1MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld1MinEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent1MinEfficiency object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 6 } cePfePerfConfigThld5MinUtilization OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrent5MinUtilization object. If during the last 5 minute measurement period the cePfePerfCurrent5MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thld5MinUtilizationEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent5MinUtilization object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 7 } cePfePerfConfigThld5MinEfficiency OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the threshold value for the cePfePerfCurrent5MinEfficiency object. If during the last 5 minute measurement period the cePfePerfCurrent5MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld5MinEfficiencyEvent' will be genera- ted. Value of zero indicates that no comparison is being made between the cePfePerfCurrent5MinEfficiency object value and the threshold value, therefore no event action will be gene- rated." DEFVAL { 0 } ::= { cePfePerfConfigEntry 8 } cePfePerfCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF CePfePerfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains PFE current running performance, which are collected at various measurement periods." ::= { cePfePerformance 2 } cePfePerfCurrentEntry OBJECT-TYPE SYNTAX CePfePerfCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing performance information applicable to a particular PFE pipeline." AUGMENTS { cePfePerfConfigEntry } ::= { cePfePerfCurrentTable 1 } CePfePerfCurrentEntry ::= SEQUENCE { cePfePerfCurrentUtilization CurrentUtilization, cePfePerfCurrentEfficiency CurrentEfficiency, cePfePerfCurrent1MinUtilization CurrentUtilization, cePfePerfCurrent1MinEfficiency CurrentEfficiency, cePfePerfCurrent5MinUtilization CurrentUtilization, cePfePerfCurrent5MinEfficiency CurrentEfficiency } cePfePerfCurrentUtilization OBJECT-TYPE SYNTAX CurrentUtilization MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the actual PFE percentage utilization. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline." ::= { cePfePerfCurrentEntry 1 } cePfePerfCurrentEfficiency OBJECT-TYPE SYNTAX CurrentEfficiency MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the actual PFE percentage efficiency. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero." ::= { cePfePerfCurrentEntry 2 } cePfePerfCurrent1MinUtilization OBJECT-TYPE SYNTAX CurrentUtilization MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the PFE percentage utilization over the previous 1 minute period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline." ::= { cePfePerfCurrentEntry 3 } cePfePerfCurrent1MinEfficiency OBJECT-TYPE SYNTAX CurrentEfficiency MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the PFE percentage efficiency over the previous 1 minute period. It is determined by the totalnumber of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero." ::= { cePfePerfCurrentEntry 4 } cePfePerfCurrent5MinUtilization OBJECT-TYPE SYNTAX CurrentUtilization MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the PFE percentage utilization over the previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline." ::= { cePfePerfCurrentEntry 5 } cePfePerfCurrent5MinEfficiency OBJECT-TYPE SYNTAX CurrentEfficiency MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the PFE percentage efficiency over the previous 5 minutes period. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero." ::= { cePfePerfCurrentEntry 6 } cePfePerfIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF CePfePerfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation." ::= { cePfePerformance 3 } cePfePerfIntervalEntry OBJECT-TYPE SYNTAX CePfePerfIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing performance information applicable to a particular PFE pipeline at a specific interval." INDEX { entPhysicalIndex, cePfePerfIntervalNumber } ::= { cePfePerfIntervalTable 1 } CePfePerfIntervalEntry ::= SEQUENCE { cePfePerfIntervalNumber Unsigned32, cePfePerfIntervalUtilization IntervalUtilization, cePfePerfIntervalEfficiency IntervalEfficiency } cePfePerfIntervalNumber OBJECT-TYPE SYNTAX Unsigned32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An interval number between 1 and 96, where 1 is the most recently completed 15 min interval and 96 is the 15 min interval completed 23 hours and 45 minutes prior to interval 1." ::= { cePfePerfIntervalEntry 1 } cePfePerfIntervalUtilization OBJECT-TYPE SYNTAX IntervalUtilization MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of processor utilization by the PFE pipeline during this completed 15 min interval." ::= { cePfePerfIntervalEntry 2 } cePfePerfIntervalEfficiency OBJECT-TYPE SYNTAX IntervalEfficiency MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of processor efficiency by the PFE pipeline during this completed 15 min interval. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero." ::= { cePfePerfIntervalEntry 3 } cePfePerfTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CePfePerfTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarted less than 24 hours ago, i.e., when there are less than 96 intervals in the cePfePerfIntervalTable, it will contain the running utiliza- tion and efficiency up to the last collected 15 minute inter- val." ::= { cePfePerformance 4 } cePfePerfTotalEntry OBJECT-TYPE SYNTAX CePfePerfTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing performance information applicable to a particular PFE pipeline at the end of each interval in the cePfePerfIntervalTable." INDEX { entPhysicalIndex } ::= { cePfePerfTotalTable 1 } CePfePerfTotalEntry ::= SEQUENCE { cePfePerfTotalUtilization TotalUtilization, cePfePerfTotalEfficiency TotalEfficiency } cePfePerfTotalUtilization OBJECT-TYPE SYNTAX TotalUtilization MAX-ACCESS read-only STATUS current DESCRIPTION "The running utilization by the PFE pipeline for the prece- ding 24 hrs." ::= { cePfePerfTotalEntry 1 } cePfePerfTotalEfficiency OBJECT-TYPE SYNTAX TotalEfficiency MAX-ACCESS read-only STATUS current DESCRIPTION "The running efficiency by the PFE pipeline for the preceding 24 hrs. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero." ::= { cePfePerfTotalEntry 2 } cePfeHistNotifiesEnable OBJECT-TYPE SYNTAX EventType MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates what type of action should be taken by the agent when a event is generated." DEFVAL { none } ::= { cePfeHistory 1} cePfeHistTableSize OBJECT-TYPE SYNTAX Unsigned32 (0..500) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the number of entries that the cePfeHistTable can contain. When a event is generated, and the capacity of the cePfeHistTable has reached the value specified by this object, then the agent deletes the oldest entity in order to accommodate the new entry. A value of '0' prevents any history from being retained." DEFVAL { 0 } ::= { cePfeHistory 2} cePfeHistTableLastIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the value of the cePfeHistIndex object corresponding to the last entry added to the table by the agent. It will return zero if there are no entries in the table. If the management client uses the notifications defined by this module, then it can poll this object to determine whether it has missed a notification sent by the agent." DEFVAL { 0 } ::= { cePfeHistory 3} cePfeHistTable OBJECT-TYPE SYNTAX SEQUENCE OF CePfeHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a history of events generated by the agent." ::= { cePfeHistory 4 } cePfeHistEntry OBJECT-TYPE SYNTAX CePfeHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry will exist for each event that has occured while cePfeHistNotifiesEnable object is set to 'log(2)' or 'logAndNotify(4)'." INDEX { cePfeHistIndex } ::= { cePfeHistTable 1 } CePfeHistEntry ::= SEQUENCE { cePfeHistIndex Unsigned32, cePfeHistEntPhysIndex PhysicalIndex, cePfeHistType HistEventType, cePfeHistThld Percentage, cePfeHistValue Percentage, cePfeHistRestartReason DisplayString, cePfeHistTimeStamp TimeStamp } cePfeHistIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An integer value uniquely identifying the entry in the table. The value of this object starts at '1' and monotonically increases for each event condition transition monitored by the agent. If the value of this object is '4294967295', the agent will reset the index to '1' upon monitoring the next event condition transition." ::= { cePfeHistEntry 1 } cePfeHistEntPhysIndex OBJECT-TYPE SYNTAX PhysicalIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value in this object is equal to the value of the entPhysicalIndex, from the Physical Entity Table (RFC 2037), that is associated with the PFE pipeline that has caused this event." ::= { cePfeHistEntry 2 } cePfeHistType OBJECT-TYPE SYNTAX HistEventType MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the type of event that has occurred." ::= { cePfeHistEntry 3 } cePfeHistThld OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-only STATUS current DESCRIPTION "The configured value of the specific threshold." ::= { cePfeHistEntry 4 } cePfeHistValue OBJECT-TYPE SYNTAX Percentage MAX-ACCESS read-only STATUS current DESCRIPTION "The actual value of the specific performance objects, at the time of the sample, which is related to the threshold event." ::= { cePfeHistEntry 5 } cePfeHistRestartReason OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for which the PFE pipeline has restarted." ::= { cePfeHistEntry 6 } cePfeHistTimeStamp OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the value of the sysUpTime object at the time the event was generated." ::= { cePfeHistEntry 7 } -- Notification Information Definitions cePfeHistThldEvent NOTIFICATION-TYPE OBJECTS { cePfeHistEntPhysIndex, cePfeHistType, cePfeHistThld, cePfeHistValue } STATUS current DESCRIPTION "This notification is generated when a threshold event has occurred and the cePfeHistNotifiesEnable is set to 'notify (3)' or 'logAndNotify(4)'. After generating this notification, another such notifica- tion will not be sent out until the sample value has fallen below the threshold value." ::= { cePfeMIBNotifications 1 } cePfeHistRestartEvent NOTIFICATION-TYPE OBJECTS { cePfeHistEntPhysIndex, cePfeHistRestartReason } STATUS current DESCRIPTION "This notification is generated when a restart event has occurred and the cePfeHistNotifiesEnable is set to 'notifyp (3)' or 'logAndNotify(4)'." ::= { cePfeMIBNotifications 2 } -- Conformance Information Definition cePfeMIBCompliances OBJECT IDENTIFIER ::= { cePfeMIBConformance 1 } cePfeMIBGroups OBJECT IDENTIFIER ::= { cePfeMIBConformance 2 } cePfeMIBPerformanceCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "An Entity-MIB implementation can implement this module to provide PFE pipeline performance history." MODULE -- this module MANDATORY-GROUPS { cePfeMIBPerformanceGroup, cePfeMIBCurrentGroup, cePfeMIBHistGroup, cePfeMIBHistEventGroup } GROUP cePfeMIBIntervalGroup DESCRIPTION "This group is optional." GROUP cePfeMIBTotalGroup DESCRIPTION "This group is optional." ::= { cePfeMIBCompliances 1 } cePfeMIBPerformanceGroup OBJECT-GROUP OBJECTS { cePfeHistTableSize, cePfeHistTableLastIndex, cePfeHistNotifiesEnable, cePfePerfConfigTimeElapsed, cePfePerfConfigValidIntervals, cePfePerfConfigThldUtilization, cePfePerfConfigThldEfficiency, cePfePerfConfigThld1MinUtilization, cePfePerfConfigThld1MinEfficiency, cePfePerfConfigThld5MinUtilization, cePfePerfConfigThld5MinEfficiency } STATUS current DESCRIPTION "The collection of objects which are used to manage the per- formance history of the PFE pipeline." ::= { cePfeMIBGroups 1 } cePfeMIBCurrentGroup OBJECT-GROUP OBJECTS { cePfePerfCurrentUtilization, cePfePerfCurrentEfficiency, cePfePerfCurrent1MinUtilization, cePfePerfCurrent1MinEfficiency, cePfePerfCurrent5MinUtilization, cePfePerfCurrent5MinEfficiency } STATUS current DESCRIPTION "The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation." ::= { cePfeMIBGroups 2 } cePfeMIBIntervalGroup OBJECT-GROUP OBJECTS { cePfePerfIntervalUtilization, cePfePerfIntervalEfficiency } STATUS current DESCRIPTION "The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation." ::= { cePfeMIBGroups 3 } cePfeMIBTotalGroup OBJECT-GROUP OBJECTS { cePfePerfTotalUtilization, cePfePerfTotalEfficiency } STATUS current DESCRIPTION "The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance." ::= { cePfeMIBGroups 4 } cePfeMIBHistGroup OBJECT-GROUP OBJECTS { cePfeHistEntPhysIndex, cePfeHistType, cePfeHistThld, cePfeHistValue, cePfeHistRestartReason, cePfeHistTimeStamp } STATUS current DESCRIPTION "The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance." ::= { cePfeMIBGroups 5 } cePfeMIBHistEventGroup NOTIFICATION-GROUP NOTIFICATIONS { cePfeHistThldEvent, cePfeHistRestartEvent } STATUS current DESCRIPTION "The collection of objects which are used to generate a threshold event for the PFE pipeline performance." ::= { cePfeMIBGroups 6 } END