cePfePerfConfigEntry |
.1.3.6.1.4.1.9.9.265.1.1.1.1 |
An entry will exist for each entry in the entPhysicalTable
that correspond to an active PFE pipeline.
|
cePfePerfCurrentEntry |
.1.3.6.1.4.1.9.9.265.1.1.2.1 |
An entry containing performance information applicable to
a particular PFE pipeline.
|
cePfePerfIntervalEntry |
.1.3.6.1.4.1.9.9.265.1.1.3.1 |
An entry containing performance information applicable to
a particular PFE pipeline at a specific interval.
|
cePfePerfTotalEntry |
.1.3.6.1.4.1.9.9.265.1.1.4.1 |
An entry containing performance information applicable to
a particular PFE pipeline at the end of each interval in the
cePfePerfIntervalTable.
|
cePfeHistNotifiesEnable |
.1.3.6.1.4.1.9.9.265.1.2.1 |
This object indicates what type of action should be taken by
the agent when a event is generated.
|
cePfeHistTableSize |
.1.3.6.1.4.1.9.9.265.1.2.2 |
This object specifies the number of entries that the
cePfeHistTable can contain. When a event is generated, and
the capacity of the cePfeHistTable has reached the value
specified by this object, then the agent deletes the oldest
entity in order to accommodate the new entry. A value of '0'
prevents any history from being retained.
|
cePfeHistTableLastIndex |
.1.3.6.1.4.1.9.9.265.1.2.3 |
This object specifies the value of the cePfeHistIndex object
corresponding to the last entry added to the table by the
agent. It will return zero if there are no entries in the
table.
If the management client uses the notifications defined by
this module, then it can poll this object to determine
whether it has missed a notification sent by the agent.
|
cePfeHistEntry |
.1.3.6.1.4.1.9.9.265.1.2.4.1 |
An entry will exist for each event that has occured while
cePfeHistNotifiesEnable object is set to 'log(2)' or
'logAndNotify(4)'.
|
cePfePerfConfigTimeElapsed |
.1.3.6.1.4.1.9.9.265.1.1.1.1.1 |
The number of seconds that have elapsed since the beginning
of the current 15 min interval. If for some reason, such as
an adjustment in the system's time-of-day clock, the current
interval exceeds the maximum value, the agent will return the
maximum value.
|
cePfePerfConfigValidIntervals |
.1.3.6.1.4.1.9.9.265.1.1.1.1.2 |
The number of completed 15 min intervals for which valid
PFE performance data has been collected. The value
will be 96 unless the interface was brought online within the
last 24 hours, in which case the value will be the number of
completed 15 minute intervals since the PFE pipeline has
been online.
|
cePfePerfConfigThldUtilization |
.1.3.6.1.4.1.9.9.265.1.1.1.1.3 |
This object contains the threshold value for the
cePfePerfCurrentUtilization object. If during the last 5
second measurement period the cePfePerfCurrentUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thldUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrentUtilization object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfConfigThldEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.1.1.4 |
This object contains the threshold value for the
cePfePerfCurrentEffciency object. If during the last 5
second measurement period the cePfePerfCurrentEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thldEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrentEfficiency object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfConfigThld1MinUtilization |
.1.3.6.1.4.1.9.9.265.1.1.1.1.5 |
This object contains the threshold value for the
cePfePerfCurrent1MinUtilization object. If during the last 1
minute measurement period the cePfePerfCurrent1MinUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thld1MinUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent1MinUtilization object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfConfigThld1MinEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.1.1.6 |
This object contains the threshold value for the
cePfePerfCurrent1MinEfficiency object. If during the last 1
minute measurement period the cePfePerfCurrent1MinEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thld1MinEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent1MinEfficiency object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfConfigThld5MinUtilization |
.1.3.6.1.4.1.9.9.265.1.1.1.1.7 |
This object contains the threshold value for the
cePfePerfCurrent5MinUtilization object. If during the last 5
minute measurement period the cePfePerfCurrent5MinUtilization
object becomes greater than or equal to this threshold value,
an event of type 'thld5MinUtilizationEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent5MinUtilization object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfConfigThld5MinEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.1.1.8 |
This object contains the threshold value for the
cePfePerfCurrent5MinEfficiency object. If during the last 5
minute measurement period the cePfePerfCurrent5MinEfficiency
object becomes less than or equal to this threshold value,
an event of type 'thld5MinEfficiencyEvent' will be genera-
ted.
Value of zero indicates that no comparison is being made
between the cePfePerfCurrent5MinEfficiency object value and
the threshold value, therefore no event action will be gene-
rated.
|
cePfePerfCurrentUtilization |
.1.3.6.1.4.1.9.9.265.1.1.2.1.1 |
This object provides the actual PFE percentage utilization.
It is determined by the number of new work contexts + feedback
contexts divided by total number of contexts that can be
supported by the PFE pipeline.
|
cePfePerfCurrentEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.2.1.2 |
This object provides the actual PFE percentage efficiency.
It is determined by the total number of contexts per second
divided by maximum theoretical contexts per second supported
by the PFE pipeline. Under normal conditions, this number will
be 100 and when efficiency starts degrading, it will start
going down until it reaches zero.
|
cePfePerfCurrent1MinUtilization |
.1.3.6.1.4.1.9.9.265.1.1.2.1.3 |
This object provides the PFE percentage utilization over the
previous 1 minute period. It is determined by the number of new
work contexts + feedback contexts divided by total number of
contexts that can be supported by the PFE pipeline.
|
cePfePerfCurrent1MinEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.2.1.4 |
This object provides the PFE percentage efficiency over the
previous 1 minute period. It is determined by the totalnumber
of contexts per second divided by maximum theoretical contexts
per second supported by the PFE pipeline. Under normal
conditions, this number will be 100 and when efficiency starts
degrading, it will start going down until it reaches zero.
|
cePfePerfCurrent5MinUtilization |
.1.3.6.1.4.1.9.9.265.1.1.2.1.5 |
This object provides the PFE percentage utilization over the
previous 5 minutes period. It is determined by the number of
new work contexts + feedback contexts divided by total number
of contexts that can be supported by the PFE pipeline.
|
cePfePerfCurrent5MinEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.2.1.6 |
This object provides the PFE percentage efficiency over the
previous 5 minutes period. It is determined by the total number
of contexts per second divided by maximum theoretical contexts
per second supported by the PFE pipeline. Under normal
conditions, this number will be 100 and when efficiency starts
degrading, it will start going down until it reaches zero.
|
cePfePerfIntervalNumber |
.1.3.6.1.4.1.9.9.265.1.1.3.1.1 |
An interval number between 1 and 96, where 1 is the most
recently completed 15 min interval and 96 is the 15 min
interval completed 23 hours and 45 minutes prior to interval
1.
|
cePfePerfIntervalUtilization |
.1.3.6.1.4.1.9.9.265.1.1.3.1.2 |
The percentage of processor utilization by the PFE pipeline
during this completed 15 min interval.
|
cePfePerfIntervalEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.3.1.3 |
The percentage of processor efficiency by the PFE pipeline
during this completed 15 min interval. Under normal conditions,
this number will be 100 and when efficiency starts degrading,
it will start going down until it reaches zero.
|
cePfePerfTotalUtilization |
.1.3.6.1.4.1.9.9.265.1.1.4.1.1 |
The running utilization by the PFE pipeline for the prece-
ding 24 hrs.
|
cePfePerfTotalEfficiency |
.1.3.6.1.4.1.9.9.265.1.1.4.1.2 |
The running efficiency by the PFE pipeline for the preceding
24 hrs. Under normal conditions, this number will be 100 and
when efficiency starts degrading, it will start going down
until it reaches zero.
|
cePfeHistIndex |
.1.3.6.1.4.1.9.9.265.1.2.4.1.1 |
An integer value uniquely identifying the entry in the table.
The value of this object starts at '1' and monotonically
increases for each event condition transition monitored by the
agent. If the value of this object is '4294967295', the agent
will reset the index to '1' upon monitoring the next event
condition transition.
|
cePfeHistEntPhysIndex |
.1.3.6.1.4.1.9.9.265.1.2.4.1.2 |
The value in this object is equal to the value of the
entPhysicalIndex, from the Physical Entity Table (RFC 2037),
that is associated with the PFE pipeline that has caused
this event.
|
cePfeHistType |
.1.3.6.1.4.1.9.9.265.1.2.4.1.3 |
This object describes the type of event that has occurred.
|
cePfeHistThld |
.1.3.6.1.4.1.9.9.265.1.2.4.1.4 |
The configured value of the specific threshold.
|
cePfeHistValue |
.1.3.6.1.4.1.9.9.265.1.2.4.1.5 |
The actual value of the specific performance objects, at the
time of the sample, which is related to the threshold event.
|
cePfeHistRestartReason |
.1.3.6.1.4.1.9.9.265.1.2.4.1.6 |
The reason for which the PFE pipeline has restarted.
|
cePfeHistTimeStamp |
.1.3.6.1.4.1.9.9.265.1.2.4.1.7 |
This object specifies the value of the sysUpTime object at
the time the event was generated.
|