AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-ENVMON-MIB

CISCO-ENVMON-MIB device MIB details by Cisco

CISCO-ENVMON-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-ENVMON-MIB.


Vendor: Cisco
Mib: CISCO-ENVMON-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- *****************************************************************
-- CISCO-ENVMON-MIB.my:  CISCO Environmental Monitor MIB file
--
-- November 1994 Sandra C. Durham/Jeffrey T. Johnson
--
-- Copyright (c) 1994-2001, 2002 by cisco Systems, Inc.
-- All rights reserved.
-- 
-- *****************************************************************
--
CISCO-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
        Gauge32,
        Integer32
                FROM SNMPv2-SMI
        TEXTUAL-CONVENTION,
        DisplayString,
        TruthValue
                FROM SNMPv2-TC
        MODULE-COMPLIANCE,
        OBJECT-GROUP,
        NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        ciscoMgmt
                FROM CISCO-SMI;


ciscoEnvMonMIB MODULE-IDENTITY
        LAST-UPDATED    "200311250000Z"
        ORGANIZATION    "Cisco Systems, Inc."
        CONTACT-INFO
                "       Cisco Systems
                        Customer Service

                Postal: 170 W Tasman Drive
                        San Jose, CA  95134
                        USA

                   Tel: +1 800 553-NETS

                E-mail: cs-snmp@cisco.com"
        DESCRIPTION
                "The MIB module to describe the status of the Environmental
                Monitor on those devices which support one."
        REVISION        "200311250000Z"
        DESCRIPTION
                "Added ciscoEnvMonMIBMiscNotifGroup."
        REVISION        "200210150000Z"
        DESCRIPTION
                "Added c7600(12) as values for ciscoEnvMonPresent"
        REVISION        "200207170000Z"
        DESCRIPTION
                "Added optional groups ciscoEnvMonEnableStatChangeGroup
                 and ciscoEnvMonStatChangeNotifGroup."
        REVISION        "200202040000Z"
        DESCRIPTION
                "Added osr7600(11) as values 
                for ciscoEnvMonPresent"        
        REVISION        "200108300000Z"
        DESCRIPTION
                "Added c10000(10) as values for ciscoEnvMonPresent"
        REVISION        "200108160000Z"
        DESCRIPTION
                "Added cat4000(9) as values for ciscoEnvMonPresent"
        REVISION        "200105070000Z"
        DESCRIPTION
                "Added cat6000(7),ubr7200(8) 
                as values for ciscoEnvMonPresent"
        REVISION        "200001310000Z"
        DESCRIPTION
                "Add notFunctioning to CiscoEnvMonState.
                "
        REVISION        "9810220000Z"
        DESCRIPTION
                "Renamed enumerated value internalRPS(5) as 
                 internalRedundant(5) and added description for
                 ciscoEnvMonSupplySource enumerated values.
                "
        REVISION        "9808050000Z"
        DESCRIPTION
                "Add enumerated value internalRPS(5) to 
                ciscoEnvMonSupplySource.
                "
        REVISION        "9611120000Z"
        DESCRIPTION
                "Add monitoring support for c3600 series router"
        REVISION        "9508150000Z"
        DESCRIPTION
                "Specify a correct (non-negative) range for several
                index objects."
        REVISION        "9503130000Z"
        DESCRIPTION
                "Miscellaneous changes including monitoring support
                for c7000 series redundant power supplies."

        ::= { ciscoMgmt 13 }


CiscoEnvMonState ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Represents the state of a device being monitored.
                 Valid values are:

                 normal(1):         the environment is good, such as low
                                    temperature.

                 warning(2):        the environment is bad, such as temperature
                                    above normal operation range but not too
                                    high.

                 critical(3):       the environment is very bad, such as
                                    temperature much higher than normal
                                    operation limit.

                 shutdown(4):       the environment is the worst, the system
                                    should be shutdown immediately.

                 notPresent(5):     the environmental monitor is not present,
                                    such as temperature sensors do not exist.

                 notFunctioning(6): the environmental monitor does not 
                                    function properly, such as a temperature
                                    sensor generates a abnormal data like
                                    1000 C.
                "
        SYNTAX  INTEGER {
                        normal(1),
                        warning(2),
                        critical(3),
                        shutdown(4),
                        notPresent(5),
                        notFunctioning(6)
                }

CiscoSignedGauge  ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Represents the current value of an entity, as a signed 
                 integer."
        SYNTAX  Integer32 

ciscoEnvMonObjects OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 1 }

ciscoEnvMonPresent OBJECT-TYPE
        SYNTAX     INTEGER {
                        oldAgs (1),
                        ags    (2),
                        c7000  (3),
                        ci     (4),
                        cAccessMon (6),
                        cat6000 (7),
                        ubr7200 (8),
                        cat4000 (9),
                        c10000 (10),
                        osr7600(11),
                        c7600  (12)
                   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The type of environmental monitor located in the chassis.
                An oldAgs environmental monitor card is identical to an ags
                environmental card except that it is not capable of supplying
                data, and hence no instance of the remaining objects in this
                MIB will be returned in response to an SNMP query.  Note that
                only a firmware upgrade is required to convert an oldAgs into
                an ags card."
        ::= { ciscoEnvMonObjects 1 }


ciscoEnvMonVoltageStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF CiscoEnvMonVoltageStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of voltage status maintained by the environmental
                monitor."
        ::= { ciscoEnvMonObjects 2 }

ciscoEnvMonVoltageStatusEntry OBJECT-TYPE
        SYNTAX     CiscoEnvMonVoltageStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the voltage status table, representing the status
                of the associated testpoint maintained by the environmental
                monitor."
        INDEX      { ciscoEnvMonVoltageStatusIndex }
        ::= { ciscoEnvMonVoltageStatusTable 1 }

CiscoEnvMonVoltageStatusEntry ::=
        SEQUENCE {
                ciscoEnvMonVoltageStatusIndex   Integer32 (0..2147483647),
                ciscoEnvMonVoltageStatusDescr   DisplayString,
                ciscoEnvMonVoltageStatusValue   CiscoSignedGauge,
                ciscoEnvMonVoltageThresholdLow  Integer32,
                ciscoEnvMonVoltageThresholdHigh Integer32,
                ciscoEnvMonVoltageLastShutdown  Integer32,
                ciscoEnvMonVoltageState         CiscoEnvMonState
        }

ciscoEnvMonVoltageStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (0..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the testpoint being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ciscoEnvMonVoltageStatusEntry 1 }

ciscoEnvMonVoltageStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the testpoint being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { ciscoEnvMonVoltageStatusEntry 2 }

ciscoEnvMonVoltageStatusValue OBJECT-TYPE
        SYNTAX     CiscoSignedGauge
        UNITS      "millivolts"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current measurement of the testpoint being instrumented."
        ::= { ciscoEnvMonVoltageStatusEntry 3 }

ciscoEnvMonVoltageThresholdLow OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "millivolts"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The lowest value that the associated instance of the object
                ciscoEnvMonVoltageStatusValue may obtain before an emergency
                shutdown of the managed device is initiated."
        ::= { ciscoEnvMonVoltageStatusEntry 4 }

ciscoEnvMonVoltageThresholdHigh OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "millivolts"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The highest value that the associated instance of the object
                ciscoEnvMonVoltageStatusValue may obtain before an emergency
                shutdown of the managed device is initiated."
        ::= { ciscoEnvMonVoltageStatusEntry 5 }

ciscoEnvMonVoltageLastShutdown OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "millivolts"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The value of the associated instance of the object
                ciscoEnvMonVoltageStatusValue at the time an emergency
                shutdown of the managed device was last initiated.  This
                value is stored in non-volatile RAM and hence is able to
                survive the shutdown."
        ::= { ciscoEnvMonVoltageStatusEntry 6 }

ciscoEnvMonVoltageState OBJECT-TYPE
        SYNTAX     CiscoEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the testpoint being instrumented."
        ::= { ciscoEnvMonVoltageStatusEntry 7 }



ciscoEnvMonTemperatureStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF CiscoEnvMonTemperatureStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of ambient temperature status maintained by the
                environmental monitor."
        ::= { ciscoEnvMonObjects 3 }

ciscoEnvMonTemperatureStatusEntry OBJECT-TYPE
        SYNTAX     CiscoEnvMonTemperatureStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the ambient temperature status table, representing
                the status of the associated testpoint maintained by the
                environmental monitor."
        INDEX      { ciscoEnvMonTemperatureStatusIndex }
        ::= { ciscoEnvMonTemperatureStatusTable 1 }

CiscoEnvMonTemperatureStatusEntry ::=
        SEQUENCE {
                ciscoEnvMonTemperatureStatusIndex       Integer32 (0..2147483647),
                ciscoEnvMonTemperatureStatusDescr       DisplayString,
                ciscoEnvMonTemperatureStatusValue       Gauge32,
                ciscoEnvMonTemperatureThreshold         Integer32,
                ciscoEnvMonTemperatureLastShutdown      Integer32,
                ciscoEnvMonTemperatureState             CiscoEnvMonState
        }


ciscoEnvMonTemperatureStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (0..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the testpoint being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ciscoEnvMonTemperatureStatusEntry 1 }

ciscoEnvMonTemperatureStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the testpoint being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { ciscoEnvMonTemperatureStatusEntry 2 }

ciscoEnvMonTemperatureStatusValue OBJECT-TYPE
        SYNTAX     Gauge32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current measurement of the testpoint being instrumented."
        ::= { ciscoEnvMonTemperatureStatusEntry 3 }

ciscoEnvMonTemperatureThreshold OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The highest value that the associated instance of the
                object ciscoEnvMonTemperatureStatusValue may obtain
                before an emergency shutdown of the managed device is
                initiated."
        ::= { ciscoEnvMonTemperatureStatusEntry 4 }

ciscoEnvMonTemperatureLastShutdown OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The value of the associated instance of the object
                ciscoEnvMonTemperatureStatusValue at the time an emergency
                shutdown of the managed device was last initiated.  This
                value is stored in non-volatile RAM and hence is able to
                survive the shutdown."
        ::= { ciscoEnvMonTemperatureStatusEntry 5 }

ciscoEnvMonTemperatureState OBJECT-TYPE
        SYNTAX     CiscoEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the testpoint being instrumented."
        ::= { ciscoEnvMonTemperatureStatusEntry 6 }



ciscoEnvMonFanStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF CiscoEnvMonFanStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of fan status maintained by the environmental
                monitor."
        ::= { ciscoEnvMonObjects 4 }

ciscoEnvMonFanStatusEntry OBJECT-TYPE
        SYNTAX     CiscoEnvMonFanStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the fan status table, representing the status of
                the associated fan maintained by the environmental monitor."
        INDEX   { ciscoEnvMonFanStatusIndex }
        ::= { ciscoEnvMonFanStatusTable 1 }

CiscoEnvMonFanStatusEntry ::=
        SEQUENCE {
                ciscoEnvMonFanStatusIndex       Integer32 (0..2147483647),
                ciscoEnvMonFanStatusDescr       DisplayString,
                ciscoEnvMonFanState             CiscoEnvMonState
        }

ciscoEnvMonFanStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (0..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the fan being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ciscoEnvMonFanStatusEntry 1 }

ciscoEnvMonFanStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the fan being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { ciscoEnvMonFanStatusEntry 2 }

ciscoEnvMonFanState OBJECT-TYPE
        SYNTAX     CiscoEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the fan being instrumented."
        ::= { ciscoEnvMonFanStatusEntry 3 }



ciscoEnvMonSupplyStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF CiscoEnvMonSupplyStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of power supply status maintained by the
                environmental monitor card."
        ::= { ciscoEnvMonObjects 5 }

ciscoEnvMonSupplyStatusEntry OBJECT-TYPE
        SYNTAX     CiscoEnvMonSupplyStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the power supply status table, representing the
                status of the associated power supply maintained by the
                environmental monitor card."
        INDEX   { ciscoEnvMonSupplyStatusIndex }
        ::= { ciscoEnvMonSupplyStatusTable 1  }

CiscoEnvMonSupplyStatusEntry ::=
        SEQUENCE {
                ciscoEnvMonSupplyStatusIndex    Integer32 (0..2147483647),
                ciscoEnvMonSupplyStatusDescr    DisplayString,
                ciscoEnvMonSupplyState          CiscoEnvMonState,
                ciscoEnvMonSupplySource         INTEGER
        }

ciscoEnvMonSupplyStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (0..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the power supply being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { ciscoEnvMonSupplyStatusEntry 1 }

ciscoEnvMonSupplyStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the power supply being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { ciscoEnvMonSupplyStatusEntry 2 }

ciscoEnvMonSupplyState OBJECT-TYPE
        SYNTAX     CiscoEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the power supply being instrumented."
        ::= { ciscoEnvMonSupplyStatusEntry 3 }

ciscoEnvMonSupplySource OBJECT-TYPE
        SYNTAX INTEGER {
                        unknown(1),
                        ac(2),
                        dc(3),
                        externalPowerSupply(4),
                        internalRedundant(5)
                }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The power supply source.
                 unknown - Power supply source unknown
                 ac      - AC power supply
                 dc      - DC power supply
                 externalPowerSupply - External power supply
                 internalRedundant - Internal redundant power supply 
                "
        ::= { ciscoEnvMonSupplyStatusEntry 4 }

ciscoEnvMonAlarmContacts OBJECT-TYPE
        SYNTAX BITS {
                        minorVisual(0),
                        majorVisual(1),
                        criticalVisual(2),
                        minorAudible(3),
                        majorAudible(4),
                        criticalAudible(5),
                        input(6)
                }

        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
                "Each bit is set to reflect the respective
                 alarm being set.  The bit will be cleared
                 when the respective alarm is cleared."
        ::= { ciscoEnvMonObjects 6 }

ciscoEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 2 }

ciscoEnvMonEnableShutdownNotification OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ciscoEnvMonShutdownNotification.  A false 
                value will prevent shutdown notifications 
                from being generated by this system."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 1 }

ciscoEnvMonEnableVoltageNotification OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      deprecated
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ciscoEnvMonVoltageNotification. A false 
                value will prevent voltage notifications from being 
                generated by this system. This object is deprecated
                in favour of ciscoEnvMonEnableStatChangeNotif."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 2 }

ciscoEnvMonEnableTemperatureNotification OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      deprecated
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ciscoEnvMonTemperatureNotification.
                A false value prevents temperature notifications 
                from being sent by  this entity. This object is 
                deprecated in favour of 
                ciscoEnvMonEnableStatChangeNotif."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 3 }

ciscoEnvMonEnableFanNotification OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      deprecated
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ciscoEnvMonFanNotification.
                A false value prevents fan notifications 
                from being sent by  this entity. This object is 
                deprecated in favour of 
                ciscoEnvMonEnableStatChangeNotif."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 4 }

ciscoEnvMonEnableRedundantSupplyNotification OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      deprecated
        DESCRIPTION
               "This variable  indicates  whether  the  system
                produces the ciscoEnvMonRedundantSupplyNotification. 
                A false value prevents redundant supply notifications
                from being generated by this system. This object is
                deprecated in favour of 
                ciscoEnvMonEnableStatChangeNotif."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 5 }

ciscoEnvMonEnableStatChangeNotif OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
               "This variable indicates whether the system
                produces the ciscoEnvMonVoltStatusChangeNotif,
                ciscoEnvMonTempStatusChangeNotif, 
                ciscoEnvMonFanStatusChangeNotif and  
                ciscoEnvMonSuppStatusChangeNotif. A false value will 
                prevent these notifications from being generated by 
                this system."
        DEFVAL { false }
        ::= { ciscoEnvMonMIBNotificationEnables 6 }

-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
-- that are backward compatible with SNMPv1 Traps.
ciscoEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 3 }
ciscoEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ciscoEnvMonMIBNotificationPrefix 0 }

ciscoEnvMonShutdownNotification NOTIFICATION-TYPE
        -- no OBJECTS
        STATUS  current
        DESCRIPTION
                "A ciscoEnvMonShutdownNotification is sent if the environmental
                monitor detects a testpoint reaching a critical state
                and is about to initiate a shutdown.  This notification 
                contains no objects so that it may be encoded and sent in the
                shortest amount of time possible.  Even so, management
                applications should not rely on receiving such a notification
                as it may not be sent before the shutdown completes."
        ::= { ciscoEnvMonMIBNotifications 1 }


ciscoEnvMonVoltageNotification NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonVoltageStatusDescr,
                ciscoEnvMonVoltageStatusValue,
                ciscoEnvMonVoltageState
                }
        STATUS  deprecated
        DESCRIPTION
                "A ciscoEnvMonVoltageNotification is sent if the voltage 
                measured at a given testpoint is outside the normal range 
                for the testpoint (i.e. is at the warning, critical, or
                shutdown stage).  Since such a notification is usually 
                generated before the shutdown state is reached, it can 
                convey more data and has a better chance of being sent 
                than does the ciscoEnvMonShutdownNotification.
                This notification is deprecated in favour of
                ciscoEnvMonVoltStatusChangeNotif."
        ::= { ciscoEnvMonMIBNotifications 2 }


ciscoEnvMonTemperatureNotification NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonTemperatureStatusDescr,
                ciscoEnvMonTemperatureStatusValue,
                ciscoEnvMonTemperatureState
                }
        STATUS  deprecated
        DESCRIPTION
                "A ciscoEnvMonTemperatureNotification is sent if the 
                temperature measured at a given testpoint is outside 
                the normal range for the testpoint (i.e. is at the warning, 
                critical, or shutdown stage).  Since such a Notification 
                is usually generated before the shutdown state is reached,
                it can convey more data and has a better chance of being
                sent than does the ciscoEnvMonShutdownNotification.
                This notification is deprecated in favour of 
                ciscoEnvMonTempStatusChangeNotif."
        ::= { ciscoEnvMonMIBNotifications 3 }



ciscoEnvMonFanNotification NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonFanStatusDescr,
                ciscoEnvMonFanState
                }
        STATUS  deprecated
        DESCRIPTION
                "A ciscoEnvMonFanNotification is sent if any one of
                the fans in the fan array (where extant) fails. 
                Since such a notification is usually generated before 
                the shutdown state is reached, it can convey more 
                data and has a better chance of being sent
                than does the ciscoEnvMonShutdownNotification.
                This notification is deprecated in favour of
                ciscoEnvMonFanStatusChangeNotif."
        ::= { ciscoEnvMonMIBNotifications 4 }

ciscoEnvMonRedundantSupplyNotification NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonSupplyStatusDescr,
                ciscoEnvMonSupplyState
                }
        STATUS  deprecated
        DESCRIPTION
                "A ciscoEnvMonRedundantSupplyNotification is sent if
                the redundant power supply (where extant) fails. 
                Since such a notification is usually generated before 
                the shutdown state is reached, it can convey more 
                data and has a better chance of being sent
                than does the ciscoEnvMonShutdownNotification.
                This notification is deprecated in favour of 
                ciscoEnvMonSuppStatusChangeNotif."
        ::= { ciscoEnvMonMIBNotifications 5 }

ciscoEnvMonVoltStatusChangeNotif NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonVoltageStatusDescr,
                ciscoEnvMonVoltageStatusValue,
                ciscoEnvMonVoltageState
                }
        STATUS  current
        DESCRIPTION
                "A ciscoEnvMonVoltStatusChangeNotif is sent if there is 
                 change in the state of a device being monitored
                 by ciscoEnvMonVoltageState."
        ::= { ciscoEnvMonMIBNotifications 6 }

ciscoEnvMonTempStatusChangeNotif NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonTemperatureStatusDescr,
                ciscoEnvMonTemperatureStatusValue,
                ciscoEnvMonTemperatureState
                }
        STATUS  current
        DESCRIPTION
                "A ciscoEnvMonTempStatusChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ciscoEnvMonTemperatureState."
        ::= { ciscoEnvMonMIBNotifications 7 }

ciscoEnvMonFanStatusChangeNotif NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonFanStatusDescr,
                ciscoEnvMonFanState
                }
        STATUS  current
        DESCRIPTION
                "A ciscoEnvMonFanStatusChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ciscoEnvMonFanState."
        ::= { ciscoEnvMonMIBNotifications 8 }

ciscoEnvMonSuppStatusChangeNotif NOTIFICATION-TYPE
        OBJECTS {
                ciscoEnvMonSupplyStatusDescr,
                ciscoEnvMonSupplyState
                }
        STATUS  current
        DESCRIPTION
                "A ciscoEnvMonSupplyStatChangeNotif is sent if there 
                 is change in the state of a device being monitored
                 by ciscoEnvMonSupplyState."
        ::= { ciscoEnvMonMIBNotifications 9 }

-- conformance information

ciscoEnvMonMIBConformance OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 4 }
ciscoEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 1 }
ciscoEnvMonMIBGroups      OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 2 }


-- compliance statements

ciscoEnvMonMIBCompliance MODULE-COMPLIANCE
        STATUS  deprecated
        DESCRIPTION
                "The compliance statement for entities which implement
                the Cisco Environmental Monitor MIB. This is
                deprecated and new compliance
                ciscoEnvMonMIBComplianceRev1 is added."
        MODULE  -- this module
                MANDATORY-GROUPS { ciscoEnvMonMIBGroup }
        ::= { ciscoEnvMonMIBCompliances 1 }

ciscoEnvMonMIBComplianceRev1 MODULE-COMPLIANCE
        STATUS  current
        DESCRIPTION
                "The compliance statement for entities which implement
                the Cisco Environmental Monitor MIB."
        MODULE  -- this module
                MANDATORY-GROUPS { ciscoEnvMonMIBGroupRev,
                                   ciscoEnvMonMIBNotifGroup }

        GROUP   ciscoEnvMonEnableStatChangeGroup
        DESCRIPTION
                "The ciscoEnvMonEnableStatChangeGroup is optional. 
                 This group is applicable for implementations which
                 need status change notifications for environmental
                 monitoring."

        GROUP   ciscoEnvMonStatChangeNotifGroup
        DESCRIPTION
                "The ciscoEnvMonStatChangeNotifGroup is optional. 
                 This group is applicable for implementations which
                 need status change notifications for environmental
                 monitoring."

        ::= { ciscoEnvMonMIBCompliances 2 }

-- units of conformance

ciscoEnvMonMIBGroup OBJECT-GROUP
        OBJECTS {
                ciscoEnvMonPresent,

                ciscoEnvMonVoltageStatusDescr,
                ciscoEnvMonVoltageStatusValue,
                ciscoEnvMonVoltageThresholdLow,
                ciscoEnvMonVoltageThresholdHigh,
                ciscoEnvMonVoltageLastShutdown,
                ciscoEnvMonVoltageState,

                ciscoEnvMonTemperatureStatusDescr,
                ciscoEnvMonTemperatureStatusValue,
                ciscoEnvMonTemperatureThreshold,
                ciscoEnvMonTemperatureLastShutdown,
                ciscoEnvMonTemperatureState,

                ciscoEnvMonFanStatusDescr,
                ciscoEnvMonFanState,

                ciscoEnvMonSupplyStatusDescr,
                ciscoEnvMonSupplyState,
                ciscoEnvMonSupplySource,

                ciscoEnvMonAlarmContacts,

                ciscoEnvMonEnableShutdownNotification,
                ciscoEnvMonEnableVoltageNotification,
                ciscoEnvMonEnableTemperatureNotification,
                ciscoEnvMonEnableFanNotification,
                ciscoEnvMonEnableRedundantSupplyNotification

        }
        STATUS  deprecated
        DESCRIPTION
                "A collection of objects providing environmental 
                monitoring capability to a cisco chassis. This group 
                is deprecated in favour of ciscoEnvMonMIBGroupRev."
        ::= { ciscoEnvMonMIBGroups 1 }

ciscoEnvMonMIBGroupRev OBJECT-GROUP
        OBJECTS {
                ciscoEnvMonPresent,

                ciscoEnvMonVoltageStatusDescr,
                ciscoEnvMonVoltageStatusValue,
                ciscoEnvMonVoltageThresholdLow,
                ciscoEnvMonVoltageThresholdHigh,
                ciscoEnvMonVoltageLastShutdown,
                ciscoEnvMonVoltageState,

                ciscoEnvMonTemperatureStatusDescr,
                ciscoEnvMonTemperatureStatusValue,
                ciscoEnvMonTemperatureThreshold,
                ciscoEnvMonTemperatureLastShutdown,
                ciscoEnvMonTemperatureState,

                ciscoEnvMonFanStatusDescr,
                ciscoEnvMonFanState,

                ciscoEnvMonSupplyStatusDescr,
                ciscoEnvMonSupplyState,
                ciscoEnvMonSupplySource,

                ciscoEnvMonAlarmContacts,

                ciscoEnvMonEnableShutdownNotification

        }
        STATUS  current
        DESCRIPTION
                "A collection of objects providing environmental 
                 monitoring capability to a cisco chassis."
        ::= { ciscoEnvMonMIBGroups 2 }

ciscoEnvMonEnableStatChangeGroup OBJECT-GROUP
        OBJECTS {
                ciscoEnvMonEnableStatChangeNotif
        }
        STATUS  current
        DESCRIPTION
                "A collection of objects providing enabling/disabling
                 of the status change notifications for environmental 
                 monitoring."
        ::= { ciscoEnvMonMIBGroups 3 }

ciscoEnvMonMIBNotifGroup NOTIFICATION-GROUP
        NOTIFICATIONS  {
                ciscoEnvMonShutdownNotification
        }
        STATUS current
        DESCRIPTION
                "A notification group providing shutdown notification
                 for environmental monitoring. "
        ::= { ciscoEnvMonMIBGroups 4 }

ciscoEnvMonStatChangeNotifGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
                 ciscoEnvMonVoltStatusChangeNotif,
                 ciscoEnvMonTempStatusChangeNotif,
                 ciscoEnvMonFanStatusChangeNotif,
                 ciscoEnvMonSuppStatusChangeNotif
        }
        STATUS   current
        DESCRIPTION
                 "A collection of notifications providing the status 
                  change for environmental monitoring."
        ::= { ciscoEnvMonMIBGroups 5 }

ciscoEnvMonMIBMiscNotifGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
                 ciscoEnvMonVoltageNotification,
                 ciscoEnvMonTemperatureNotification,
                 ciscoEnvMonFanNotification,
                 ciscoEnvMonRedundantSupplyNotification
        }
        STATUS   deprecated
        DESCRIPTION
                 "A collection of various notifications for the 
                 enviromental monitoring mib module. The notifications
                 the group and the group are both in deprecated state.
                 The notifications in the group were deprecated in 
                 favour of notifications in
                 ciscoEnvMonStatChangeNotifGroup."
        ::= { ciscoEnvMonMIBGroups 6 }

END