AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-FCPING-MIB

CISCO-FCPING-MIB device MIB details by Cisco

CISCO-FCPING-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-FCPING-MIB.


Vendor: Cisco
Mib: CISCO-FCPING-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- *********************************************************************
-- CISCO-FCPING-MIB.my: Fibre Channel Ping Mib
--
-- September 2002, H K Vivek
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
-- 
-- *********************************************************************

CISCO-FCPING-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,OBJECT-TYPE,
        NOTIFICATION-TYPE,
        Gauge32,Unsigned32, Integer32      FROM    SNMPv2-SMI
        MODULE-COMPLIANCE, OBJECT-GROUP,
        NOTIFICATION-GROUP                 FROM    SNMPv2-CONF
        RowStatus, TruthValue,
        TEXTUAL-CONVENTION                 FROM    SNMPv2-TC
        ciscoMgmt                          FROM    CISCO-SMI
        VsanIndex, FcAddress,                          
        FcAddressType                      FROM    CISCO-ST-TC;
          

ciscoFcPingMIB  MODULE-IDENTITY
        LAST-UPDATED "200210070000Z"
        ORGANIZATION "Cisco Systems Inc."
        CONTACT-INFO 
                "     Cisco Systems
                      Customer Service
                Postal: 170 W Tasman Drive
                      San Jose, CA  95134
                      USA
                Tel: +1 800 553 -NETS
                E-mail: cs-san@cisco.com"
        DESCRIPTION
                "The MIB module for the management of the
                 Fibre Channel Ping functionality."
        REVISION "200210070000Z"
        DESCRIPTION
                "Initial version of this MIB module."
        ::= { ciscoMgmt 295 }

ciscoFcPingMIBObjects OBJECT IDENTIFIER ::= { ciscoFcPingMIB 1 }
fcPingMIBConformance  OBJECT IDENTIFIER ::= { ciscoFcPingMIB 2 }
fcPingConfiguration   OBJECT IDENTIFIER 
                      ::= { ciscoFcPingMIBObjects 1 }
fcPingStats           OBJECT IDENTIFIER 
                      ::= { ciscoFcPingMIBObjects 2 }
fcPingNotification    OBJECT IDENTIFIER 
                      ::= { ciscoFcPingMIBObjects 3 }
fcPingNotifications   OBJECT IDENTIFIER ::= { fcPingNotification 0 }

-- Textual conventions

FcStartOper ::= TEXTUAL-CONVENTION
        STATUS     current
        DESCRIPTION
                "Enable/disable an operation.
                 enable(1) - enable the operation.
                 disable(2) - disable the operation."
        SYNTAX  INTEGER {
                   enable(1),
                   disable(2)
                }

-- Ping Requests Table

fcPingTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF FcPingEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "A table of ping request entries.
                 This table contains a set of ping requests
                 which need to be executed at the agent."
        ::= { fcPingConfiguration 1 }


fcPingEntry OBJECT-TYPE
        SYNTAX     FcPingEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "A ping request entry.

                 A management station wishing to create an entry
                 should generate a pseudo-random number to be 
                 used as an index into this table and create an 
                 instance of the fcPingRowStatus object. After that, 
                 the management station should set the corresponding 
                 instance of fcPingAddress object with the address of 
                 the destination that should be pinged and 
                 fcPingVsanIndex with the desired VSAN number.

                 Once the appropriate instance of all the configuration
                 objects have been created, either by an explicit SNMP
                 set request or by default, the row status should be 
                 set to active to initiate the ping sequence. Note that
                 this entire procedure may be initiated via a single
                 set request which specifies a row status of 
                 createAndGo as well as specifies valid values for the 
                 non-defaulted configuration objects. 

                 Once the ping sequence has been initiated it can
                 be stopped by setting the corresponding instance
                 of fcPingRowStatus to 'destroy'.

                 The results of the ping operation are made available
                 in the fcPingStats table. For a ping entry uniquely
                 identified by fcPingIndex, an entry will be created 
                 in the fcPingStats table automatically by the agent. 

                 Once the ping sequence completes, the management 
                 station should retrieve the statistics of interest 
                 from the fcPingStats table and delete the entry from 
                 the fcPingTable. The corresponding entry in the
                 fcPingStats table shall be deleted automatically by 
                 the agent.

                 In order to prevent old entries from clogging the 
                 table, entries will be aged out, but an entry will 
                 never be deleted within fcPingAgeInterval 
                 milliseconds of completing.

                 If the management station wishes to repeat the ping
                 sequence to a particular destination, then it will
                 need to set the corresponding instance of 
                 fcPingAdminStatus to 'enable' again."
        INDEX { fcPingIndex }
        ::= { fcPingTable 1 }

FcPingEntry ::= SEQUENCE {
        fcPingIndex               Integer32,
        fcPingVsanIndex           VsanIndex,
        fcPingAddressType         FcAddressType,
        fcPingAddress             FcAddress,
        fcPingPacketCount         Unsigned32,
        fcPingPayloadSize         Unsigned32,
        fcPingPacketTimeout       Unsigned32,
        fcPingDelay               Unsigned32,
        fcPingAgeInterval         Unsigned32,
        fcPingUsrPriority         INTEGER,
        fcPingAdminStatus         FcStartOper,
        fcPingOperStatus          INTEGER,
        fcPingTrapOnCompletion    TruthValue,
        fcPingRowStatus           RowStatus
}

fcPingIndex OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "The index of a ping entry. This object uniquely
                 identifies a ping request entry on a VSAN."
        ::= { fcPingEntry 1 }

fcPingVsanIndex OBJECT-TYPE
        SYNTAX      VsanIndex
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "This object identifies the VSAN to which this ping
                 request belongs. This object cannot be modified
                 if the corresponding instance of fcPingOperStatus
                 object has a value of 'inProgress'."
        DEFVAL { 1 }
        ::= { fcPingEntry 2 }

fcPingAddressType OBJECT-TYPE
        SYNTAX      FcAddressType
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The format of the corresponding instance of
                 fcPingAddress object."
        DEFVAL { wwn }
        ::= { fcPingEntry 3 }

fcPingAddress OBJECT-TYPE
        SYNTAX      FcAddress
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The address of the device to be pinged.

                 If the value of the corresponding instance of
                 fcPingAddressType object is 'wwn', then this
                 object will contain an 8 octet long WWN.

                 If the value of the corresponding instance of
                 fcPingAddressType object is 'fcid', then this
                 object will contain a 3 octet long FCID.

                 This object MUST be set to a valid value before
                 or concurrently with setting the corresponding
                 instance of fcPingRowStatus to 'active'."
        ::= { fcPingEntry 4 }

fcPingPacketCount OBJECT-TYPE
        SYNTAX      Unsigned32 (1..2147483647)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The number of ping packets to be sent to the
                 target in this sequence. This object cannot
                 be modified if the corresponding instance
                 of fcPingOperStatus object has a value of
                 'inProgress'."
        DEFVAL { 5 }
        ::= { fcPingEntry 5 }

fcPingPayloadSize OBJECT-TYPE
        SYNTAX      Unsigned32 (0..1884)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "This object specifies the size of the ping packet
                 payload to be sent to the target in this sequence.
                 This object cannot be modified if the
                 corresponding instance of fcPingOperStatus object
                 has a value of 'inProgress'."
        DEFVAL { 0 }
        ::= { fcPingEntry 6 }

fcPingPacketTimeout OBJECT-TYPE
        SYNTAX      Unsigned32 (1..10)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The amount of time to wait for a response to a 
                 transmitted packet before declaring the packet
                 'dropped'. This object cannot be modified if
                 the corresponding instance of fcPingOperStatus
                 object has a value of 'inProgress'."
        DEFVAL { 2 }
        ::= { fcPingEntry 7 }

fcPingDelay OBJECT-TYPE
        SYNTAX      Unsigned32 (0..3600000)
        UNITS       "milliseconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The minimum amount of time to wait before sending 
                 the next packet in a sequence, after receiving a 
                 response or declaring a timeout for a previously
                 transmitted packet. This object cannot be
                 modified if the corresponding instance of
                 fcPingOperStatus object has a value of
                 'inProgress'."
        DEFVAL { 0 }
        ::= { fcPingEntry 8 }

fcPingAgeInterval OBJECT-TYPE
        SYNTAX      Unsigned32 (500000..900000)
        UNITS       "milliseconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The amount of time to wait after the ping sequence
                 completes before the ping entry is aged out.
                 This object cannot be modified if the
                 corresponding instance of fcPingOperStatus object
                 has a value of 'inProgress'."
        DEFVAL { 500000 }
        ::= { fcPingEntry 9 }

fcPingUsrPriority OBJECT-TYPE
        SYNTAX      INTEGER {
                       high(1), -- user priority is high
                       low(2) -- user priority is low
                    }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "This object determines the queuing priority
                 and drop probability this sequence of ping
                 packets experience in the switches through
                 which they pass through.

                 If the value of this object is set to 'high',
                 then the corresponding sequence of packets
                 will experience high queueing priority and
                 low drop probability in the switches through
                 which they pass through.

                 If the value of this object is set to 'low',
                 then the corresponding sequence of packets
                 will experience low queueing priority and
                 higher drop probability in the switches 
                 through which they pass through.
                
                 This object cannot be modified if the
                 corresponding instance of fcPingOperStatus
                 object has a value of 'inProgress'."
        DEFVAL { low }
        ::= { fcPingEntry 10 }

fcPingAdminStatus OBJECT-TYPE
        SYNTAX      FcStartOper
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "This object specifies the desired state that a 
                 fcPingEntry should be in:

                 enable(1)  -  Attempt to activate the ping as 
                               defined by this entry.

                 disable(2) -  Deactivate the ping as defined by
                               this entry.

                 The actual operational state of this test is 
                 indicated by the corresponding instance of 
                 fcPingOperStatus.

                 When the ping sequence corresponding to this entry
                 is executing, this object cannot be modified. If this
                 object is read at such a time, a value of 'enable' 
                 will be returned. When the ping sequence completes, 
                 the value of this object will be made 'disable' 
                 automatically by the agent."
        DEFVAL { disable }
        ::= { fcPingEntry 11 }

fcPingOperStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                       inProgress(1), -- ping is in progress
                       complete(2), -- ping is complete
                       disabled(3), -- ping is disabled
                       failure(4) -- ping failure
                    }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "This object indicates the operational status
                 of this fcPingEntry.

                 inProgress(1)  -  Indicates that the ping sequence
                                   as defined by this instance of
                                   fcPingEntry is currently running.

                 complete(2)    -  Indicates that the ping sequence
                                   as defined by this instance of
                                   fcPingEntry is currently 
                                   complete.

                 disabled(3)    -  Indicates that the ping sequence
                                   as defined by this instance of
                                   fcPingEntry is currently disabled.
 
                 failure(4)     -  Indicates that the ping sequence
                                   as defined by this instance of
                                   fcPingEntry has currently failed 
                                   due to resource limitations.

                 Initially the value of this object will be
                 'inProgress' when the ping sequence is being
                 executed. Once the ping sequence is completed,
                 the value of this object will transition to
                 'complete'.

                 If the value of the corresponding instance of
                 fcPingAdminStatus is 'disable', then this object
                 will have a value of 'disabled'."
        ::= { fcPingEntry 12 }

fcPingTrapOnCompletion OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "This specifies if fcPingCompletionNotify notification
                 should be generated or not when the corresponding
                 ping sequence completes.

                 If this object is set to 'true', then the 
                 notification is generated.

                 If this object is set to 'false', then the 
                 notification is not generated.

                 This object cannot be modified if the
                 corresponding instance of fcPingOperStatus
                 object has a value of 'inProgress'."
        DEFVAL { false }
        ::= { fcPingEntry 13 }


fcPingRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The status of this conceptual row.

                 When a ping sequence is being executed, if this
                 object is set to 'destroy', then the
                 corresponding ping sequence will be stopped."
        ::= { fcPingEntry 14 }


-- Ping Statistics

fcPingStatsTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF FcPingStatsEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "A table of ping statistics.
                 The statistics corresponding to the entries
                 in the fcPingTable. When an entry is deleted
                 in the fcPingTable, the corresponding entry
                 in this table is deleted automatically by
                 the agent."
        ::= { fcPingStats 1 }

fcPingStatsEntry OBJECT-TYPE
        SYNTAX      FcPingStatsEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "A ping statistics entry.

                 An entry shall be created automatically in this
                 table whenever a ping request is activated in the
                 fcPingTable by setting the fcPingRowStatus to
                 'active'. This entry shall have the same indices
                 as the entry that got activated in the fcPingTable.

                 An entry in this table shall be deleted by the
                 agent automatically either when the corresponding
                 entry in the fcPingTable is deleted by the
                 management station or is aged out by the agent.

                 This table shall be empty if there is no 'active'
                 entry in the fcPingTable."
        INDEX { fcPingIndex }
        ::= { fcPingStatsTable 1 }

FcPingStatsEntry ::= SEQUENCE {
        fcPingTxPackets       Gauge32,
        fcPingRxPackets       Gauge32,
        fcPingMinRtt          Integer32,
        fcPingAvgRtt          Integer32,
        fcPingMaxRtt          Integer32,
        fcPingNumTimeouts     Gauge32
}

fcPingTxPackets OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The number of ping packets sent to the target in 
                 this sequence."
        ::= { fcPingStatsEntry 1 }

fcPingRxPackets OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The number of ping packets received from the target
                 in this sequence."
        ::= { fcPingStatsEntry 2 }

fcPingMinRtt OBJECT-TYPE
        SYNTAX      Integer32 (0..10000000)
        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The minimum round trip time of all the packets that
                 have been sent in this sequence."
        ::= { fcPingStatsEntry 3 }

fcPingAvgRtt OBJECT-TYPE
        SYNTAX      Integer32 (0..10000000)
        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The average round trip time of all the packets that
                 have been sent in this sequence."
        ::= { fcPingStatsEntry 4 }

fcPingMaxRtt OBJECT-TYPE
        SYNTAX      Integer32 (0..10000000)
        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The maximum round trip time of all the packets that
                 have been sent in this sequence."
        ::= { fcPingStatsEntry 5 }

fcPingNumTimeouts OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "The number of timeouts encountered in this sequence."
        ::= { fcPingStatsEntry 6 }


        
-- Notifications

fcPingCompletionNotify NOTIFICATION-TYPE
        OBJECTS  {fcPingAddress, fcPingTxPackets, fcPingRxPackets}
        STATUS   current
        DESCRIPTION
                "This notification is generated whenever a sequence
                 of pings is complete and the corresponding instance
                 of fcPingTrapOnCompletion object has been set to 
                 'true'."
        ::= { fcPingNotifications 1 }



		

-- Conformance

fcPingMIBCompliances OBJECT IDENTIFIER ::= { fcPingMIBConformance 1 }
fcPingMIBGroups      OBJECT IDENTIFIER ::= { fcPingMIBConformance 2 }

fcPingMIBCompliance MODULE-COMPLIANCE
        STATUS  current
        DESCRIPTION
                "The compliance statement for entities which
                 implement the Fibre Channel Ping module."
        MODULE MANDATORY-GROUPS {fcPingConfigGroup,
                                 fcPingStatsGroup,
                                 fcPingNotifyGroup}

        OBJECT     fcPingRowStatus             
        SYNTAX     INTEGER {             
                     active(1),
                     createAndGo(4),
                     destroy(6)}
        MIN-ACCESS read-create
        DESCRIPTION 
                "Only three values 'createAndGo', 'destroy' and 
                'active' out of the six enumerated values need to be
                supported."
        ::= { fcPingMIBCompliances 1 }


-- Units of conformance

fcPingConfigGroup OBJECT-GROUP
        OBJECTS {fcPingVsanIndex,
                 fcPingAddressType,
                 fcPingAddress,
                 fcPingPacketCount,
                 fcPingPayloadSize,
                 fcPingPacketTimeout,
                 fcPingDelay,
                 fcPingAgeInterval,
                 fcPingUsrPriority,
                 fcPingAdminStatus,
                 fcPingOperStatus,
                 fcPingTrapOnCompletion,
                 fcPingRowStatus}
        STATUS  current
        DESCRIPTION
                "A collection of objects for configuring 
                 Fibre Channel Ping."
        ::= { fcPingMIBGroups 1 }


fcPingStatsGroup OBJECT-GROUP
        OBJECTS {fcPingTxPackets,
                 fcPingRxPackets,
                 fcPingMinRtt,
                 fcPingAvgRtt,
                 fcPingMaxRtt,
                 fcPingNumTimeouts}
        STATUS  current
        DESCRIPTION
                "A collection of objects for displaying 
                 Fibre Channel Ping statistics."
        ::= { fcPingMIBGroups 2 }


fcPingNotifyGroup NOTIFICATION-GROUP
        NOTIFICATIONS {fcPingCompletionNotify}
        STATUS  current
        DESCRIPTION
                "A collection of notification(s) for monitoring
                 Fibre Channel Ping completion."
        ::= { fcPingMIBGroups 3 }


END