AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-OPTICAL-MONITORING-MIB

CISCO-OPTICAL-MONITORING-MIB device MIB details by Cisco

CISCO-OPTICAL-MONITORING-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-OPTICAL-MONITORING-MIB.


Vendor: Cisco
Mib: CISCO-OPTICAL-MONITORING-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
--

-- CISCO-OPTICAL-MONITORING-MIB.my : used for monitoring physical

-- parameters of optical interfaces.

-- Nov 2001, Arif Shouqi 

-- Copyright (c) 1999-2001 by Cisco Systems, Inc.

-- All rights reserved.

--



-- Caution.  This MIB is temporary and experimental.  In the future it

-- will be removed from products, perhaps with short notice, in favor

-- of more standard or generic MIBs.  Application developers should not

-- depend on long-term access to this MIB.



CISCO-OPTICAL-MONITORING-MIB DEFINITIONS ::= BEGIN



      IMPORTS

         MODULE-IDENTITY, OBJECT-TYPE, Integer32  

                                       FROM SNMPv2-SMI

         TruthValue                    FROM SNMPv2-TC

         MODULE-COMPLIANCE, OBJECT-GROUP 

                                       FROM SNMPv2-CONF

         ciscoExperiment               FROM CISCO-SMI

         ifIndex                       FROM IF-MIB;



ciscoOpticalMonitoringMIB MODULE-IDENTITY

       LAST-UPDATED   "200112041130Z"

       ORGANIZATION   "Cisco Systems, Inc."

       CONTACT-INFO   "Cisco Systems

                                   Customer Service



                                   Postal: 170 W Tasman Drive

                                   San Jose, CA 95134



                                   Tel: +1 800 553-NETS



                                   E-mail: gsr-netman@cisco.com" 

       DESCRIPTION

            "This MIB module is used to monitor optical parameters

            of a network element.This MIB deals with the operating

            parameters of the optical layer. The optical layer is a

            term that defines all the devices/systems that deal with

            the conversion of data in it's electrical form to optical

            form, transmission of the optical data, reception, and 

            finally re-conversion to electrical signals."

       REVISION     "200112041130Z"

       DESCRIPTION

            "Initial version of the MIB."

 ::= { ciscoExperiment  83 }



ciscoOpticalMonMIBObjects  OBJECT IDENTIFIER ::= 

                                { ciscoOpticalMonitoringMIB 1 }



comParameters  OBJECT IDENTIFIER ::= { ciscoOpticalMonMIBObjects 1 }



-- comParameters



comParametersTable  OBJECT-TYPE

     SYNTAX      SEQUENCE OF ComParametersEntry

     MAX-ACCESS  not-accessible

     STATUS      current

     DESCRIPTION

          "This table lists the instrumented parameters of all

          interfaces on the network element whose optical

          parameters are to be monitored."

     REFERENCE

          "ITU recommendations G.783, G.784, G.953"

     ::= { comParameters 1 }



comParametersEntry  OBJECT-TYPE

     SYNTAX      ComParametersEntry

     MAX-ACCESS  not-accessible

     STATUS      current

     DESCRIPTION

          "Only the ifIndices of optical interfaces

          whose parameters need to be monitored will

          be used to index this table."

     INDEX       { ifIndex }

     ::= { comParametersTable 1 }



ComParametersEntry ::=

     SEQUENCE  {

         comTxBiasCurrent         Integer32,

         comTxPowerSupported      TruthValue,

         comTxPower               Integer32,

         comTxLaserTempSupported  TruthValue, 

         comTxLaserTemp           Integer32,

         comRxPowerACDC           Integer32,

         comRxPowerACSupported    TruthValue,

         comRxPowerAC             Integer32

     }



comTxBiasCurrent  OBJECT-TYPE

      SYNTAX  Integer32  ( 0..100000 )

      UNITS  "milliamps"

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "This  holds the value of the laser diode forward

            bias current for the interface being instrumented,

            and is an indication of the Tx optical power."

     ::= { comParametersEntry 1 }



comTxPowerSupported  OBJECT-TYPE

      SYNTAX  TruthValue

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "Boolean to indicate if the interface being instrumented

            supports comTxPower. comTxPowerSupported is set to true

            if the interface supports the comTxPower object, and set

            to false otherwise."

     ::= { comParametersEntry 2 }



comTxPower  OBJECT-TYPE

      SYNTAX  Integer32  ( 0..2147483647 )

      UNITS  "microWatts"

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "This object holds the value of the transmitter optical

            power for the interface being instrumented. The optical

            is proportional to the laser diode current. This object

            makes sense only if comTxPowerSupported is true. All 

            values must be converted to microWatts."

     ::= { comParametersEntry 3 }



comTxLaserTempSupported  OBJECT-TYPE

      SYNTAX  TruthValue

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "Boolean to indicate if the interface being instrumented

            supports comTxLaserTemp. comTxLaserTempSupported is set 

            to true if the interface supports the comTxLaserTemp 

            object, and set to false otherwise."

     ::= { comParametersEntry 4 }



comTxLaserTemp  OBJECT-TYPE

      SYNTAX  Integer32 ( -253..200 )

      UNITS  " Degree Centigrade"

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "This object holds the value of the transmitter laser 

            diode temperature for the interface being instrumented.

            This object indicates the health of the transmitter."

    ::= { comParametersEntry 5 }



comRxPowerACDC  OBJECT-TYPE

      SYNTAX  Integer32 ( 0..2147483647 )

      UNITS "microWatts"

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "This object holds the value of the total power

            (AC + DC) at the optical  Rx of the interface.

            All values must be converted to microWatts."

    ::= { comParametersEntry 6 }



comRxPowerACSupported  OBJECT-TYPE

      SYNTAX  TruthValue

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "Boolean to indicate if comRxPowerAC is supported by 

            the interface being instrumented. comRxPowerACSupported

            is set to true if the interface supports the comRxPowerAC 

            object,and set to false otherwise."

    ::= { comParametersEntry 7 }



comRxPowerAC  OBJECT-TYPE

      SYNTAX  Integer32 ( 0..2147483647 )

      UNITS "microWatts"

      MAX-ACCESS  read-only

      STATUS  current

      DESCRIPTION

           "This object holds the value of the AC power at

            the optical Receiver of the interface. Not all

            interfaces support this object.This object makes

            sense only if comRxPowerACSupported is true. All

            values must be converted to microWatts."

    ::= { comParametersEntry 8 }



-- Notifications



ciscoOpticalMonMIBNotifPrefix OBJECT IDENTIFIER ::=

                                   { ciscoOpticalMonitoringMIB 2 }



ciscoOpticalMonMIBNotifications OBJECT IDENTIFIER ::=

                                   { ciscoOpticalMonMIBNotifPrefix 0 }



-- Conformance



ciscoOpticalMonMIBConformance  OBJECT IDENTIFIER ::= 

                                   { ciscoOpticalMonitoringMIB 3 }

ciscoOpticalMonMIBCompliances OBJECT IDENTIFIER ::=

                                   { ciscoOpticalMonMIBConformance 1 }

ciscoOpticalMonMIBGroups      OBJECT IDENTIFIER ::= 

                                   { ciscoOpticalMonMIBConformance 2 }



ciscoOpticalMonMIBCompliance MODULE-COMPLIANCE

    STATUS current

    DESCRIPTION

         "The compliance statement for entities which implement

          the Cisco Optical Monitoring MIB."

    MODULE -- this module

    MANDATORY-GROUPS { ciscoOpticalMonMIBParamGroup }

 ::= { ciscoOpticalMonMIBCompliances 1 }



-- Units of Conformance



ciscoOpticalMonMIBParamGroup OBJECT-GROUP

 OBJECTS {

    comTxBiasCurrent,

    comTxPowerSupported,

    comTxPower,

    comTxLaserTempSupported,

    comTxLaserTemp,

    comRxPowerACDC,

    comRxPowerACSupported,

    comRxPowerAC    

    }

 STATUS current

 DESCRIPTION

      "Parameters of the optical interfaces."

 ::= { ciscoOpticalMonMIBGroups 1 }



END