AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Cisco » CISCO-SDSL-LINE-MIB

CISCO-SDSL-LINE-MIB device MIB details by Cisco

CISCO-SDSL-LINE-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-SDSL-LINE-MIB.


Vendor: Cisco
Mib: CISCO-SDSL-LINE-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- *****************************************************************
-- Description of managed objects for SDSL line interfaces.
--
-- 03/10/2000 Andy Spooner
--            Patrick Gili
--
-- Copyright (c) 1999, 2000, 2001 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************

CISCO-SDSL-LINE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Counter32,
    Gauge32,
    Integer32,
    MODULE-IDENTITY,
    OBJECT-TYPE                         FROM SNMPv2-SMI
    TruthValue,
    VariablePointer,
    TEXTUAL-CONVENTION                  FROM SNMPv2-TC
    MODULE-COMPLIANCE,
    OBJECT-GROUP                        FROM SNMPv2-CONF
    ciscoMgmt                           FROM CISCO-SMI
    AdslLineProfileName,
    adslLineConfProfileName,
    adslLineAlarmConfProfileName        FROM ADSL-LINE-MIB
    ifIndex                             FROM IF-MIB
    SnmpAdminString                     FROM SNMP-FRAMEWORK-MIB
    PerfCurrentCount,
    PerfIntervalCount                   FROM PerfHist-TC-MIB;


ciscoSdslLineMIB MODULE-IDENTITY
    LAST-UPDATED   "200108201000Z"
    ORGANIZATION   "Cisco Systems, Inc."
    CONTACT-INFO   "Cisco Systems
                    Customer Service

                    Postal: 170 W Tasman Drive
                    San Jose, CA 95134

                    Tel: +1 800 553-NETS

                    E-mail: cs-dslam@cisco.com"
    DESCRIPTION
        "This MIB module describes all variations of the symmetric
        DSL line interfaces.  The structure of this module resembles
        and maintains consistency with the ADSL-LINE-MIB,
        ADSL-DMT-LINE-MIB, CISCO-ADSL-DMT-LINE-MIB, and
        CISCO-ADSL-CAP-LINE-MIB. Observe that the tables in this
        module do not necessarily extend the tables defined by the
        these mibs. Currently, only those tables that contain
        configuration information extend the profile tables defined
        by the above modules.  This allows the management
        client to define DSL configuration profiles that apply across
        all DSL modems, independent of the technology being utilized by
        the modem.

        *** DEFINITIONS ***

        ATTENUATION
          Attenuation is a decrease in the strength of a signal
          over the length of a cable.

        CODING VIOLATION
            A coding violation occurs when the incoming signal exhibits
            a CRC anomaly.

        DOWNSTREAM
            The flow of data in the direction from the ATU-C to ATU-R.

        ERRORED SECOND
            A second with one or more coding violations or one or more
            incoming defects (e.g., LOS or LOSQ).

        LINE RATE
            The total data rate supported by a line.  Observe that the
            payload rate is equal the line rate for the earliest
            implementations of SDSL.  However, the payload rate maybe
            less than the line rate for future implementations.

        LOSS OF SYNC DEFECT
            A Loss of Sync Defect is defined as 3 consecutive received
            frames which contain one or more errors in the framing
            bits. A Loss of Sync Defect shall be cleared when at least
            2 consecutive received frames contain no errors in the
            framing bits.

        LOSS OF SYNC FAILURE
             A LOSW Failure is defined as at least 2 consecutive
             seconds of LOSW Defect.  The LOSW Failure should be
             cleared when the LOSW defect is absent for 20 seconds or
             less. (i.e. clear within 20 seconds ).

        MARGIN (also referred to as 'SNR margin')
            The difference between the SNR of the received signal and
            the SNR required to provide a BER of 10E-7.

        SEVERELY ERRORED SECOND
            A one second interval during which or more LOSW or CV defects
            are declared.

        UNAVAILABLE SECOND
            A Unavailable Second is defined as a one second interval
            during which LOSW Failure ( at least 2 seconds of LOSW
            Defect ).

        UPSTREAM
            The flow of data in the direction from the ATU-R to ATU-C.

        *** ABBREVIATIONS, ACRONYMS, AND SYMBOLS ***

        ADSL - Asymmetric Digital Subscriber Line.

        ATM - Asynchronous Transfer Mode.

        BER - Bit Error Ratio.

        CV - Coding Violation.

        DSL - Digital Subscriber Line.

        ES - Errored Second.

        LOS - Loss Of Sync.

        LOSQ - Loss Of Signal Quality.

        LOSW - Loss of Sync Word Failure

        PSD - Power Spectral Density.

        SES - Severely Errored Second.

        SNR - Signal-to-Noise Ratio.

        STM - Synchronous Transfer Mode.

        STU-C - SDSL Transceiver Unit, Central Office end.

        STU-R - ADSL Transceiver Unit, Remote terminal end.

        UAS - UnAvailable Second."

    REVISION    "200108201000Z"
    DESCRIPTION
        "The object cSdslStucCurrGain and cSdslSturCurrGain are
        deprecated to remove the range. The new objects added are
        cSdslStucCurrGainRev and cSdslSturCurrGainRev."
    REVISION    "200104091013Z" -- April 9, 2001 10:13 AM
    DESCRIPTION
        "Added cSdslSturAnnex for G.shdsl CPE device. Also updated
         description for cSdslStucAnnex. "
    REVISION        "200101301600Z"
    DESCRIPTION
        "Added cSdslLineEquipmentType, cSdslLineAutoRateEnable.
        cSdslShdslLineMaxRate, cSdslStucPsdMaskType, cSdslStucAnnex,
        and cSdslStucThresholdSnrMgn. Changed default for
        cSdslLineMaxRate. Updated description for SNR and output
        pwr profile settings."

    ::= { ciscoMgmt 155 }

-- Textual Conventions

SdslPerfTimeElapsed ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "The number of seconds that have elapsed since the beginning of
        the current measurement period.  If, for some reason, such as an
        adjustment in the system's time-of-day clock, the current
        interval exceeds the maximum value, the agent will return the
        maximum value."
    SYNTAX Gauge32

SdslPerfCurrDayCount ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "A counter associated with interval performance measurements in
        a current 1-day (24 hour) measurement interval.

        The value of this counter starts at zero at the beginning of an
        interval and increases when associated events occur, until the
        end of the 1-day interval.  At that time, the agent stores the
        value of the counter in the previous 1-day history interval,
        if available, and resets the value of the counter to zero.

        In the case where the agent has no valid data available for this
        interval, the corresponding object instance is not available.
        In this case, the agent will respond with the appropriate error
        indicating that the instance does not exist; that is,
        'noSuchName' in response to a SNMPv1 get request, and
        'noSuchInstance' in response to a SNMPv2 get request."
    SYNTAX Gauge32

SdslPerfPrevDayCount ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "A counter associated with interval performance measurements
        during the most previous 1-day (24 hour) measurement interval.
        The value of this counter is equal to the current day counter
        at the end of its most recent interval.

        In the case where the agent has no valid data available for this
        interval, the corresponding object instance is not available.
        In this case, the agent will respond with the appropriate error
        indicating that the instance does not exist; that is,
        'noSuchName' in response to a SNMPv1 get request, and
        'noSuchInstance' in response to a SNMPv2 get request."
    SYNTAX Gauge32

SdslStuxDefect ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
        "This object specifies any possible defects currently being
        exhibited by the STU-x.  The value of this object is a bitmap
        of possible defects.  The following list summarizes the
        meaning of each bit in the bitmap

        0   lossOfSignal            The STU-x is not receiving signal.

        1   lossOfSignalQuality     The upstream SNR margin has fallen
                                    below the SNR margin required to
                                    maintain a minimum BER of 10^-7.

        2   noPeerStuPresent        The STU-x can not initialize due
                                    to the absence of a peer STU-x.

        3   lossOfSyncFailure       The STU-x has suffered from at
                                    least 2 consecutive seconds of
                                    LOSW defect."
    SYNTAX      BITS {
        lossOfSignal(0),
        lossOfSignalQuality(1),
        noPeerStuPresent(2),
        lossOfSyncFailure(3)
    }

-- MIB Objects Definitions

ciscoSdslLineMIBObjects OBJECT IDENTIFIER ::= { ciscoSdslLineMIB 1 }

-- SDSL Line Table

cSdslLineTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslLineEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains the enterprise-specific common attributes
        describing both ends of SDSL lines supported by the system."
    ::= { ciscoSdslLineMIBObjects 1 }

cSdslLineEntry OBJECT-TYPE
    SYNTAX      CSdslLineEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A set of enterprise-specific common attributes describing both
        ends of an SDSL line supported by the system.  There exists an
        entry for each ifEntry with an ifType of sdsl(96)."
    INDEX       { ifIndex }
    ::= { cSdslLineTable 1 }

CSdslLineEntry ::= SEQUENCE {
    cSdslLineCoding             INTEGER,
    cSdslLineFraming            INTEGER,
    cSdslLineSpecific           VariablePointer,
    cSdslLineConfProfile        AdslLineProfileName,
    cSdslLineAlarmConfProfile   AdslLineProfileName
}

cSdslLineCoding OBJECT-TYPE
    SYNTAX      INTEGER {
        other(1),   --
        base2b1q(2),-- Baseband, 2B1Q encoding.  SDSL ports may use 2b1q
                    --    line coding.
        tcPam(3),   -- Trellis Coded Pulse Amplitude Modulated.
                    --    G.shdsl ports use tcPam line coding.
        optis(4),   -- Overlapped Pulse Amplitude Modulated
                    --    Transmission with Interlocked Spectra.  HDSL2
                    --    ports use optis line coding.
        cap(5)      -- Carrierless Amplitude/Phase Modulation.  SDSL
                    --    may use cap line coding.
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies encoding of signal used by this line.  Other types
        may be added in the future."
    REFERENCE
        "ITU Draft G.Shdsl, Single-Pair High Speed Digital Subscriber
         Line(SHDSL) Transceivers,

        T1E1.4, Draft for HDSL2 Standard, Default Letter Ballot,

        ITU-T G991.1, High-Bit-Rate Digital Subscriber Transceivers(HDSL)"
    ::= { cSdslLineEntry 1 }

cSdslLineFraming OBJECT-TYPE
    SYNTAX      INTEGER {
        none(1),            -- no frame format
        other(2),           --
        hdsl(3),            -- HDSL frame format for SDSL interaces
        gShdsl(4),          -- G.SHDSL frame format for G.SHDSL
        hdsl2(5),           -- HDSL2 frame format for HDSL2 interfaces
        ds1(6)              -- DS1 frame format for HDSL2 interfaces
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the current Transmission Convergence
        framing structure being used by the interface."
    REFERENCE
        "ITU Draft G.Shdsl, Single-Pair High Speed Digital Subscriber
        Line(SHDSL) Transceivers,

        T1E1.4, Draft for HDSL2 Standard, Default Letter Ballot,

       ITU-T G991.1, High-Bit-Rate Digital Subscriber Transceivers(HDSL)"

    ::= { cSdslLineEntry 2}


cSdslLineSpecific OBJECT-TYPE
    SYNTAX      VariablePointer
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
         "This object specifies an object identifier of an instance of
         an object in the MIB.  The implementation determines the
         application of this object.   For example, an implementation
         may use this object to provide a reference to the port-class
         physical entity (see the ENTITY-MIB for further details)
         corresponding to the SDSL line."
    ::= { cSdslLineEntry  3 }


cSdslLineConfProfile OBJECT-TYPE
    SYNTAX      AdslLineProfileName
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the row in the adslLineConfProfileTable
        (see the ADSL-LINE-MIB for further details), which applies for
        this SDSL line interface.

        In the case the implementation utilizes 'dynamic mode' (see
        the ADSL-LINE-MIB for further details), then the value of this
        object defaults to the name of a configuration profile
        designated by the implementation as the default configuration
        profile.

        In the case the implementation utilizes 'static mode', then the
        the value of this object is read-only."
    ::= { cSdslLineEntry 4 }

cSdslLineAlarmConfProfile OBJECT-TYPE
    SYNTAX      AdslLineProfileName
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object specifies the row in the
        adslLineAlarmConfProfileTable (see the ADSL-LINE-MIB for further
        details), which applies for this SDSL line interface.

        In the case the implementation utilizes 'dynamic mode' (see
        the ADSL-LINE-MIB for further details), then the value of this
        object defaults to the name of an alarm configuration profile
        designated by the implementation as the default alarm
        configuration profile.

        In the case the implementation utilizes 'static mode', then the
        the value of this object is read-only."
    ::= { cSdslLineEntry 5 }

-- SDSL STU-C Physical-Layer Parameters Table

cSdslStucPhysTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslStucPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains enterprise-specific physical layer
        parameters for STU-C class devices supported by the system."
    ::= { ciscoSdslLineMIBObjects 2 }

cSdslStucPhysEntry OBJECT-TYPE
    SYNTAX      CSdslStucPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A set of enterprise-specific physical-layer parameters for an
        STU-C class device supported by the system.  There exists an
        entry for each ifEntry with an ifType of sdsl(96)."
    INDEX       { ifIndex }
    ::= { cSdslStucPhysTable 1 }

CSdslStucPhysEntry ::= SEQUENCE {
    cSdslStucInvSerialNumber    SnmpAdminString,
    cSdslStucInvVendorId        SnmpAdminString,
    cSdslStucInvVersionNumber   SnmpAdminString,
    cSdslStucState              INTEGER,
    cSdslStucDefect             SdslStuxDefect,
    cSdslStucCurrRate           Integer32,
    cSdslStucCurrSnrMgn         Gauge32,
    cSdslStucCurrGain           Integer32, --deprecated
    cSdslStucCurrOutputPwr      Gauge32,
    cSdslStucCurrAtn            Gauge32,
    cSdslStucCurrGainRev        Integer32
}

cSdslStucInvSerialNumber OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor specific string that
        identifies the vendor STU-C."
    ::= { cSdslStucPhysEntry 1 }

cSdslStucInvVendorId OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor identifier assigned according
        to T1.220"
    REFERENCE
        "ANSI T1.220-1991 Coded Representation of the North American
        Telecommunication Industry Manufacturers, Suppliers,
        and Related Service Companies"
    ::= { cSdslStucPhysEntry 2 }

cSdslStucInvVersionNumber OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor specific version number of
        the STU-C."
    ::= { cSdslStucPhysEntry 3 }

cSdslStucState OBJECT-TYPE
    SYNTAX      INTEGER {
        other(1),           --
        idle(2),            -- Administratively down.
        training(3),        -- Transceiver training in progress.
        steadyState(4),     -- Nominal mode of operation.
        testing(5),         -- Transceiver in loopback or running BERT.
        downloading(6),     -- STU-C code download in progress.
        downloadFailed(7)   -- STU-C code download failed.
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the state of the STU-C transceiver."
    ::= { cSdslStucPhysEntry 4 }

cSdslStucDefect OBJECT-TYPE
    SYNTAX      SdslStuxDefect
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies any possible defects currently being
        exhibited by the STU-C.

        This object has the intention of supplementing ifOperStatus."
    ::= { cSdslStucPhysEntry 5 }

cSdslStucCurrRate OBJECT-TYPE
    SYNTAX      Integer32 (0..2320000)
    UNITS       "bps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the rate the STU-C transceiver was
        able to obtain following training."
    ::= { cSdslStucPhysEntry 6 }

cSdslStucCurrSnrMgn OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the SNR margin as seen by this STU-C with
        respect to its received signal."
    ::= { cSdslStucPhysEntry 7 }

cSdslStucCurrGain OBJECT-TYPE
    SYNTAX      Integer32 (-200..200)
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "This object specifies gain applied to this STU-C's receiver.
        This object is deprecated by cSdslStucCurrGainRev which has
        no specified range."
    ::= { cSdslStucPhysEntry 8 }

cSdslStucCurrOutputPwr OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "tenth dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the measured total output power
        transmitted by this STU-C.  This is the measurement that was
        reported during the last activation sequence."
    ::= { cSdslStucPhysEntry 9 }

cSdslStucCurrAtn OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "tenth dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Measured difference in the total power transmitted by
         the peer STU-R and the total power received by this STU-C."
    ::= { cSdslStucPhysEntry 10 }

cSdslStucCurrGainRev OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies gain applied to this STU-C's receiver.
        This object deprecates cSdslStucCurrGainRev and has
        no specified range."
    ::= { cSdslStucPhysEntry 11 }

-- SDSL STU-R Physical-Layer Parameters Table

cSdslSturPhysTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslSturPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains enterprise-specific physical layer
        parameters for STU-R class devices supported by the system.

--      Note to implementor:
--      If the implementation does not support remote management
--      of STU-R class devices, then the agent must respond with
--      the appropriate error indicating that the instance does not
--      exist; that is, 'noSuchName' in response to a SNMPv1 get
--      request, 'noSuchInstance' in response to a SNMPv2 get
--      request or a null string for string types."

    ::= { ciscoSdslLineMIBObjects 3 }

cSdslSturPhysEntry OBJECT-TYPE
    SYNTAX      CSdslSturPhysEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A set of enterprise-specific physical-layer parameters for an
        STU-R class device supported by the system.  There exists an
        entry for each ifEntry with an ifType of sdsl(96)."
    INDEX       { ifIndex }
    ::= { cSdslSturPhysTable 1 }

CSdslSturPhysEntry ::= SEQUENCE {
    cSdslSturInvSerialNumber    SnmpAdminString,
    cSdslSturInvVendorId        SnmpAdminString,
    cSdslSturInvVersionNumber   SnmpAdminString,
    cSdslSturState              INTEGER,
    cSdslSturDefect             SdslStuxDefect,
    cSdslSturCurrRate           Integer32,
    cSdslSturCurrSnrMgn         Gauge32,
    cSdslSturCurrGain           Integer32, --deprecated
    cSdslSturCurrOutputPwr      Gauge32,
    cSdslSturCurrAtn            Gauge32,
    cSdslSturCurrGainRev        Integer32
}

cSdslSturInvSerialNumber OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor specific string that
        identifies the vendor STU-R."
    ::= { cSdslSturPhysEntry 1 }

cSdslSturInvVendorId OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor identifier assigned according
        to T1.220"
    REFERENCE
        "ANSI T1.220-1991 Coded Representation of the North American
        Telecommunication Industry Manufacturers, Suppliers,
        and Related Service Companies"
    ::= { cSdslSturPhysEntry 2 }

cSdslSturInvVersionNumber OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..16))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the vendor specific version number of
        the STU-R."
    ::= { cSdslSturPhysEntry 3 }

cSdslSturState OBJECT-TYPE
    SYNTAX      INTEGER {
        other(1),           --
        training(2),        -- Transceiver training in progress.
        steadyState(3)      -- Nominal mode of operation.
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the state of the STU-R transceiver."
    ::= { cSdslSturPhysEntry 4 }

cSdslSturDefect OBJECT-TYPE
    SYNTAX      SdslStuxDefect
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies any possible defects currently being
        exhibited by the STU-R.

        This object has the intention of supplementing ifOperStatus."
    ::= { cSdslSturPhysEntry 5 }

cSdslSturCurrRate OBJECT-TYPE
    SYNTAX      Integer32(0..2320000)
    UNITS       "bps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the rate the STU-R transceiver was
        able to obtain following training."
    ::= { cSdslSturPhysEntry 6 }

cSdslSturCurrSnrMgn OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the SNR margin as seen by this STU-R with
        respect to its received signal."
    ::= { cSdslSturPhysEntry 7 }

cSdslSturCurrGain OBJECT-TYPE
    SYNTAX      Integer32(-200..200)
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "This object specifies gain applied to this STU-R's receiver.
        This object is deprecated by cSdslSturCurrGainRev which has
        no specified range."
    ::= { cSdslSturPhysEntry 8 }

cSdslSturCurrOutputPwr OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the measured total output power
        transmitted by this STU-R.  This is the measurement that was
        reported during the last activation sequence."
    ::= { cSdslSturPhysEntry 9 }

cSdslSturCurrAtn OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "tenth dBm"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Measured difference in the total power transmitted by
         the peer STU-C and the total power received by this STU-R"
    ::= { cSdslSturPhysEntry 10 }

cSdslSturCurrGainRev OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "tenth dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies gain applied to this STU-R's receiver.
        This object deprecates by cSdslSturCurrGain and has
        no specified range."
    ::= { cSdslSturPhysEntry 11 }

-- SDSL STU-C Performance Data Table

cSdslStucPerfDataTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslStucPerfDataEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains physical-layer statistics for STU-C class
        devices supported by the system."
    ::= { ciscoSdslLineMIBObjects 6 }

cSdslStucPerfDataEntry OBJECT-TYPE
    SYNTAX      CSdslStucPerfDataEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A set of physical-layer statistics for an STU-C class device
        supported by the system.  There exists an entry for each ifEntry
        with an ifType of sdsl(96)."
    REFERENCE
        "ITU Draft G.Shdsl, Single-Pair High Speed Digital Subscriber
         Line(SHDSL) Transceivers,

        T1E1.4, Draft for HDSL2 Standard, Default Letter Ballot,

        ITU-T G991.1, High-Bit-Rate Digital Subscriber Transceivers(HDSL),

        Tesink, K., Textual Conventions for MIB Modules Using
        Performance History Based on 15 Minute Intervals, RFC 2493,
        January 1999."
    INDEX       { ifIndex }


    ::= { cSdslStucPerfDataTable 1 }

CSdslStucPerfDataEntry ::= SEQUENCE {
    cSdslStucPerfLOSs                   Counter32,
    cSdslStucPerfLOSQs                  Counter32,
    cSdslStucPerfCVs                    Counter32,
    cSdslStucPerfESs                    Counter32,
    cSdslStucPerfSESs                   Counter32,
    cSdslStucPerfUASs                   Counter32,
    cSdslStucPerfInits                  Counter32,
    cSdslStucUnavailRsrcs                    Counter32,
    cSdslStucPerfValidIntervals         Integer32,
    cSdslStucPerfInvalidIntervals       Integer32,
    cSdslStucPerfCurr15MinTimeElapse    SdslPerfTimeElapsed,
    cSdslStucPerfCurr15MinLOSs          PerfCurrentCount,
    cSdslStucPerfCurr15MinLOSQs         PerfCurrentCount,
    cSdslStucPerfCurr15MinCVs           PerfCurrentCount,
    cSdslStucPerfCurr15MinESs           PerfCurrentCount,
    cSdslStucPerfCurr15MinSESs          PerfCurrentCount,
    cSdslStucPerfCurr15MinUASs          PerfCurrentCount,
    cSdslStucPerfCurr15MinInits         PerfCurrentCount,
    cSdslStucPerfCurr15MinUnavlRsrcs    PerfCurrentCount,
    cSdslStucPerfCurr1DayTimeElapsed    SdslPerfTimeElapsed,
    cSdslStucPerfCurr1DayLOSs           SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayLOSQs          SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayCVs            SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayESs            SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DaySESs           SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayUASs           SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayInits          SdslPerfCurrDayCount,
    cSdslStucPerfCurr1DayUnavlRsrcs     SdslPerfCurrDayCount,
    cSdslStucPerfPrev1DayMoniSecs       Integer32,
    cSdslStucPerfPrev1DayLOSs           SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayLOSQs          SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayCVs            SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayESs            SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DaySESs           SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayUASs           SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayInits          SdslPerfPrevDayCount,
    cSdslStucPerfPrev1DayUnavlRsrcs     SdslPerfPrevDayCount
}

cSdslStucPerfLOSs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of LOS failures experienced
        by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 1 }

cSdslStucPerfLOSQs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of LOSQ failures experienced
        by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 2 }

cSdslStucPerfCVs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 3 }

cSdslStucPerfESs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 4 }

cSdslStucPerfSESs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored
        seconds experienced by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 5 }

cSdslStucPerfUASs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-C since agent reset."
    ::= { cSdslStucPerfDataEntry 6 }

cSdslStucPerfInits OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of line initializations
        attempted by the STU-C since agent reset.  This value includes
        both successful and failed attempts."
    ::= { cSdslStucPerfDataEntry 7 }

cSdslStucUnavailRsrcs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of packets discarded on the
        STU-C due to unavailable resources, such as lack of buffer
        space."
    ::= { cSdslStucPerfDataEntry 8}

cSdslStucPerfValidIntervals OBJECT-TYPE
    SYNTAX      Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of previous near end intervals for
        which valid data was collected.  The value will be
        96 unless the interface was brought online within
        the last 24 hours, in which case the value will be
        the number of complete 15 minute near end
        intervals since the interface has been online."
    ::= { cSdslStucPerfDataEntry 9}

cSdslStucPerfInvalidIntervals OBJECT-TYPE
    SYNTAX      Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of near-end performance data 15-minute intervals in
        the range from 0 to cSdslStucPerfValidIntervals for which no
        data is available. This object will typically be zero except in
        cases where the data for some intervals are not available (e.g.,
        in proxy situations)."
    ::= { cSdslStucPerfDataEntry 10 }

cSdslStucPerfCurr15MinTimeElapse OBJECT-TYPE
    SYNTAX      SdslPerfTimeElapsed (0..899)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of seconds that have elapsed since the beginning of
        the current measurement period.  If, for some reason, such as an
        adjustment in the system's time-of-day clock, the current
        interval exceeds the maximum value, the agent will return
        the maximum value."
    ::= { cSdslStucPerfDataEntry 11 }

cSdslStucPerfCurr15MinLOSs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        15-minute interval when the STU-C experienced LOS."
    ::= { cSdslStucPerfDataEntry 12 }

cSdslStucPerfCurr15MinLOSQs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        15-minute interval when the STU-C experienced LOSQ."
    ::= { cSdslStucPerfDataEntry 13 }

cSdslStucPerfCurr15MinCVs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-C in the current 15-minute interval."
    ::= { cSdslStucPerfDataEntry 14 }

cSdslStucPerfCurr15MinESs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-C in the current 15-minute interval."
    ::= { cSdslStucPerfDataEntry 15 }

cSdslStucPerfCurr15MinSESs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-C in the current 15-minute interval."
    ::= { cSdslStucPerfDataEntry 16 }

cSdslStucPerfCurr15MinUASs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-C in the current 15-minute interval."
    ::= { cSdslStucPerfDataEntry 17 }

cSdslStucPerfCurr15MinInits OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of line initializations
        attempted by the STU-C in the current 15-minute interval."
    ::= { cSdslStucPerfDataEntry 18 }

cSdslStucPerfCurr15MinUnavlRsrcs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of packets discarded on the
        STU-C due to unavailable resources, such as lack of buffer
        space, in the current 15 minute interval."
    ::= { cSdslStucPerfDataEntry 19 }

cSdslStucPerfCurr1DayTimeElapsed OBJECT-TYPE
    SYNTAX      SdslPerfTimeElapsed (0..86399)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of seconds that have elapsed since the beginning of
        the current measurement period.  If, for some reason, such as an
        adjustment in the system's time-of-day clock, the current
        interval exceeds the maximum value, the agent will return
        the maximum value."
    ::= { cSdslStucPerfDataEntry 20 }

cSdslStucPerfCurr1DayLOSs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds experienced by the
        STU-C in the current 1-day interval when there was LOS."
    ::= { cSdslStucPerfDataEntry 21 }

cSdslStucPerfCurr1DayLOSQs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds experienced by the
        STU-C in the current 1-day interval when there was LOSQ."
    ::= { cSdslStucPerfDataEntry 22 }

cSdslStucPerfCurr1DayCVs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-C in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 23}

cSdslStucPerfCurr1DayESs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-C in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 24 }

cSdslStucPerfCurr1DaySESs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-C in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 25 }

cSdslStucPerfCurr1DayUASs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-C in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 26 }

cSdslStucPerfCurr1DayInits OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of line initializations
        attempted by the STU-C in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 27 }

cSdslStucPerfCurr1DayUnavlRsrcs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of packets discarded on the
        STU-C due to unavailable resources, such as lack of buffer
        space, in the current 1-day interval."
    ::= { cSdslStucPerfDataEntry 28 }

cSdslStucPerfPrev1DayMoniSecs OBJECT-TYPE
    SYNTAX      Integer32 (0..86400)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The amount of time in the previous 1-day interval over which
        the performance monitoring information is actually counted.
        This value will be the same as the interval duration except
        in a situation where performance monitoring data could not be
        collected for any reason."
    ::= { cSdslStucPerfDataEntry 29 }

cSdslStucPerfPrev1DayLOSs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        1-day interval when the STU-C experienced LOS."
    ::= { cSdslStucPerfDataEntry 30 }

cSdslStucPerfPrev1DayLOSQs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the previous
        1-day interval when the STU-C experienced LOSQ."
    ::= { cSdslStucPerfDataEntry 31 }

cSdslStucPerfPrev1DayCVs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-C in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 32 }

cSdslStucPerfPrev1DayESs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-C in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 33 }

cSdslStucPerfPrev1DaySESs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-C in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 34 }

cSdslStucPerfPrev1DayUASs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-C in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 35 }

cSdslStucPerfPrev1DayInits OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of line initializations
        attempted by the STU-C in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 36 }

cSdslStucPerfPrev1DayUnavlRsrcs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of packets discarded on the
        STU-C due to unavailable resources, such as lack of buffer
        space, in the previous 1-day interval."
    ::= { cSdslStucPerfDataEntry 37 }

-- SDSL STU-R Performance Data Table

cSdslSturPerfDataTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslSturPerfDataEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains physical-layer statistics for STU-R class
        devices supported by the system.

--      Note to implementor:
--      If the implementation does not support remote management
--      of STU-R class devices, then the agent must respond with
--      the appropriate error indicating that the instance does not
--      exist; that is, 'noSuchName' in response to a SNMPv1 get
--      request, and 'noSuchInstance' in response to a SNMPv2 get
--      request."

    ::= { ciscoSdslLineMIBObjects 7 }

cSdslSturPerfDataEntry OBJECT-TYPE
    SYNTAX      CSdslSturPerfDataEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A set of physical-layer statistics for an STU-R class device
        supported by the system.  There exists an entry for each ifEntry
        with an ifType of sdsl(96)."
    REFERENCE

        "ITU Draft G.Shdsl, Single-Pair High Speed Digital Subscriber
         Line(SHDSL) Transceivers,

        T1E1.4, Draft for HDSL2 Standard, Default Letter Ballot,

        ITU-T G991.1, High-Bit-Rate Digital Subscriber Transceivers(HDSL)"


    INDEX       { ifIndex }
    ::= { cSdslSturPerfDataTable 1 }

CSdslSturPerfDataEntry ::= SEQUENCE {
    cSdslSturPerfLOSs                   Counter32,
    cSdslSturPerfLOSQs                  Counter32,
    cSdslSturPerfCVs                    Counter32,
    cSdslSturPerfESs                    Counter32,
    cSdslSturPerfSESs                   Counter32,
    cSdslSturPerfUASs                   Counter32,
    cSdslSturPerfValidIntervals         Integer32,
    cSdslSturPerfInvalidIntervals       Integer32,
    cSdslSturPerfCurr15MinTimeElapse    SdslPerfTimeElapsed,
    cSdslSturPerfCurr15MinLOSs          PerfCurrentCount,
    cSdslSturPerfCurr15MinLOSQs         PerfCurrentCount,
    cSdslSturPerfCurr15MinCVs           PerfCurrentCount,
    cSdslSturPerfCurr15MinESs           PerfCurrentCount,
    cSdslSturPerfCurr15MinSESs          PerfCurrentCount,
    cSdslSturPerfCurr15MinUASs          PerfCurrentCount,
    cSdslSturPerfCurr1DayTimeElapsed    SdslPerfTimeElapsed,
    cSdslSturPerfCurr1DayLOSs           SdslPerfCurrDayCount,
    cSdslSturPerfCurr1DayLOSQs          SdslPerfCurrDayCount,
    cSdslSturPerfCurr1DayCVs            SdslPerfCurrDayCount,
    cSdslSturPerfCurr1DayESs            SdslPerfCurrDayCount,
    cSdslSturPerfCurr1DaySESs           SdslPerfCurrDayCount,
    cSdslSturPerfCurr1DayUASs           SdslPerfCurrDayCount,
    cSdslSturPerfPrev1DayMoniSecs       Integer32,
    cSdslSturPerfPrev1DayLOSs           SdslPerfPrevDayCount,
    cSdslSturPerfPrev1DayLOSQs          SdslPerfPrevDayCount,
    cSdslSturPerfPrev1DayCVs            SdslPerfPrevDayCount,
    cSdslSturPerfPrev1DayESs            SdslPerfPrevDayCount,
    cSdslSturPerfPrev1DaySESs           SdslPerfPrevDayCount,
    cSdslSturPerfPrev1DayUASs           SdslPerfPrevDayCount
}

cSdslSturPerfLOSs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of LOS failures experienced
        by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 1 }

cSdslSturPerfLOSQs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of LOSQ failures experienced
        by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 2 }

cSdslSturPerfCVs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 3 }

cSdslSturPerfESs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 4 }

cSdslSturPerfSESs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored
        seconds experienced by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 5 }

cSdslSturPerfUASs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-R since agent reset."
    ::= { cSdslSturPerfDataEntry 6 }

cSdslSturPerfValidIntervals OBJECT-TYPE
    SYNTAX      Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of previous far end intervals for
        which valid data was collected.  The value will be
        96 unless the interface was brought online within
        the last 24 hours, in which case the value will be
        the number of complete 15 minute far end
        intervals since the interface has been online."
    ::= { cSdslSturPerfDataEntry 7 }

cSdslSturPerfInvalidIntervals OBJECT-TYPE
    SYNTAX      Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of far-end performance data 15-minute intervals in
        the range from 0 to cSdslSturPerfValidIntervals for which no
        data is available. This object will typically be zero except in
        cases where the data for some intervals are not available (e.g.,
        in proxy situations)."
    ::= { cSdslSturPerfDataEntry 8 }

cSdslSturPerfCurr15MinTimeElapse OBJECT-TYPE
    SYNTAX      SdslPerfTimeElapsed (0..899)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of seconds that have elapsed since the beginning of
        the current measurement period.  If, for some reason, such as an
        adjustment in the system's time-of-day clock, the current
        interval exceeds the maximum value, the agent will return
        the maximum value."
    ::= { cSdslSturPerfDataEntry 9 }

cSdslSturPerfCurr15MinLOSs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        15-minute interval when the STU-R experienced LOS."
    ::= { cSdslSturPerfDataEntry 10 }

cSdslSturPerfCurr15MinLOSQs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        15-minute interval when the STU-R experienced LOSQ."
    ::= { cSdslSturPerfDataEntry 11 }

cSdslSturPerfCurr15MinCVs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-R in the current 15-minute interval."
    ::= { cSdslSturPerfDataEntry 12 }

cSdslSturPerfCurr15MinESs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-R in the current 15-minute interval."
    ::= { cSdslSturPerfDataEntry 13 }

cSdslSturPerfCurr15MinSESs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-R in the current 15-minute interval."
    ::= { cSdslSturPerfDataEntry 14 }

cSdslSturPerfCurr15MinUASs OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-R in the current 15-minute interval."
    ::= { cSdslSturPerfDataEntry 15 }

cSdslSturPerfCurr1DayTimeElapsed OBJECT-TYPE
    SYNTAX      SdslPerfTimeElapsed (0..86399)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of seconds that have elapsed since the beginning of
        the current measurement period.  If, for some reason, such as an
        adjustment in the system's time-of-day clock, the current
        interval exceeds the maximum value, the agent will return
        the maximum value."
    ::= { cSdslSturPerfDataEntry 16 }

cSdslSturPerfCurr1DayLOSs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds experienced by the
        STU-R in the current 1-day interval when there was LOS."
    ::= { cSdslSturPerfDataEntry 17 }

cSdslSturPerfCurr1DayLOSQs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds experienced by the
        STU-R in the current 1-day interval when there was LOSQ."
    ::= { cSdslSturPerfDataEntry 18 }

cSdslSturPerfCurr1DayCVs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-R in the current 1-day interval."
    ::= { cSdslSturPerfDataEntry 19 }

cSdslSturPerfCurr1DayESs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-R in the current 1-day interval."
    ::= { cSdslSturPerfDataEntry 20 }

cSdslSturPerfCurr1DaySESs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-R in the current 1-day interval."
    ::= { cSdslSturPerfDataEntry 21 }

cSdslSturPerfCurr1DayUASs OBJECT-TYPE
    SYNTAX      SdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-R in the current 1-day interval."
    ::= { cSdslSturPerfDataEntry 22 }

cSdslSturPerfPrev1DayMoniSecs OBJECT-TYPE
    SYNTAX      Integer32 (0..86400)
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The amount of time in the previous 1-day interval over which
        the performance monitoring information is actually counted.
        This value will be the same as the interval duration except
        in a situation where performance monitoring data could not be
        collected for any reason."
    ::= { cSdslSturPerfDataEntry 23 }

cSdslSturPerfPrev1DayLOSs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the current
        1-day interval when the STU-R experienced LOS."
    ::= { cSdslSturPerfDataEntry 24 }

cSdslSturPerfPrev1DayLOSQs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the previous
        1-day interval when the STU-R experienced LOSQ."
    ::= { cSdslSturPerfDataEntry 25 }

cSdslSturPerfPrev1DayCVs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-R in the previous 1-day interval."
    ::= { cSdslSturPerfDataEntry 26 }

cSdslSturPerfPrev1DayESs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-R in the previous 1-day interval."
    ::= { cSdslSturPerfDataEntry 27 }

cSdslSturPerfPrev1DaySESs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-R in the previous 1-day interval."
    ::= { cSdslSturPerfDataEntry 28 }

cSdslSturPerfPrev1DayUASs OBJECT-TYPE
    SYNTAX      SdslPerfPrevDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-R in the previous 1-day interval."
    ::= { cSdslSturPerfDataEntry 29 }

-- SDSL STU-C Performance Data Interval Table

cSdslStucIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslStucIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains physical-layer statistics intervals for
        STU-C class devices supported by the system.  The interval
        tables are modeled after RFC 2493, Textual Conventions for
        MIB Modules Using Performance History Based on 15 Minute
        Intervals, RFC 2493"

    REFERENCE

        "Tesink, K., Textual Conventions for MIB Modules Using
        Performance History Based on 15 Minute Intervals, RFC 2493,
        January 1999."

    ::= { ciscoSdslLineMIBObjects 8 }

cSdslStucIntervalEntry OBJECT-TYPE
    SYNTAX      CSdslStucIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A 15-miute interval of physical-layer statistics for a STU-C
        class device supported by the system.  There exists up to 96
        entries for each ifEntry with an ifType of sdsl(96)."
    INDEX       { ifIndex, cSdslStucIntervalNumber }
    ::= { cSdslStucIntervalTable 1 }

CSdslStucIntervalEntry ::= SEQUENCE {
    cSdslStucIntervalNumber     Integer32,
    cSdslStucIntervalValidData  TruthValue,
    cSdslStucIntervalLOSs       PerfIntervalCount,
    cSdslStucIntervalLOSQs      PerfIntervalCount,
    cSdslStucIntervalCVs        PerfIntervalCount,
    cSdslStucIntervalESs        PerfIntervalCount,
    cSdslStucIntervalSESs       PerfIntervalCount,
    cSdslStucIntervalUASs       PerfIntervalCount,
    cSdslStucIntervalInits      PerfIntervalCount,
    cSdslStucIntervalUnavlRsrcs PerfIntervalCount
}

cSdslStucIntervalNumber OBJECT-TYPE
    SYNTAX      Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The interval in which the statistics were collected, where the
        value of 1 represents the most recent interval, and the value of
        96 represents the interval collected 24 hours ago.  Intervals
        2..96 are optional."
    ::= { cSdslStucIntervalEntry 1 }

cSdslStucIntervalValidData OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies whether the data for this interval
        is valid."
    ::= { cSdslStucIntervalEntry 2 }

cSdslStucIntervalLOSs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the interval
        when the STU-C experienced LOS."
    ::= { cSdslStucIntervalEntry 3 }

cSdslStucIntervalLOSQs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the interval
        when the STU-C experienced LOSQ."
    ::= { cSdslStucIntervalEntry 4 }

cSdslStucIntervalCVs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-C in the interval."
    ::= { cSdslStucIntervalEntry 5 }

cSdslStucIntervalESs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-C in the interval."
    ::= { cSdslStucIntervalEntry 6 }

cSdslStucIntervalSESs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-C in the interval."
    ::= { cSdslStucIntervalEntry 7 }

cSdslStucIntervalUASs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-C in the interval."
    ::= { cSdslStucIntervalEntry 8 }

cSdslStucIntervalInits OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of line initializations
        attempted by the STU-C in the interval."
    ::= { cSdslStucIntervalEntry 9 }

cSdslStucIntervalUnavlRsrcs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of packets discarded on the
        STU-C due to unavailable resources, such as lack of buffer
        space in the interval."
    ::= { cSdslStucIntervalEntry 10 }

-- SDSL STU-R Perforamnce Data Interval Table

cSdslSturIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslSturIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains physical-layer statistics intervals for
        STU-R class devices supported by the system.  The interval
        tables are modeled after RFC 2493, Textual Conventions for
        MIB Modules Using Performance History Based on 15 Minute
        Intervals, RFC 2493"

--      Note to implementor:
--      If the implementation does not support remote management
--      of STU-R class devices, then the agent must respond with
--      the appropriate error indicating that the instance does not
--      exist; that is, 'noSuchName' in response to a SNMPv1 get
--      request, and 'noSuchInstance' in response to a SNMPv2 get
--      request.

    REFERENCE

        "Tesink, K., Textual Conventions for MIB Modules Using
        Performance History Based on 15 Minute Intervals, RFC 2493,
        January 1999."

    ::= { ciscoSdslLineMIBObjects 9 }

cSdslSturIntervalEntry OBJECT-TYPE
    SYNTAX      CSdslSturIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A 15-miute interval of physical-layer statistics for a STU-R
        class device supported by the system.  There exists up to 96
        entries for each ifEntry with an ifType of sdsl(96)."
    INDEX       { ifIndex, cSdslSturIntervalNumber }
    ::= { cSdslSturIntervalTable 1 }

CSdslSturIntervalEntry ::= SEQUENCE {
    cSdslSturIntervalNumber     Integer32,
    cSdslSturIntervalLOSs       PerfIntervalCount,
    cSdslSturIntervalLOSQs      PerfIntervalCount,
    cSdslSturIntervalCVs        PerfIntervalCount,
    cSdslSturIntervalESs        PerfIntervalCount,
    cSdslSturIntervalSESs       PerfIntervalCount,
    cSdslSturIntervalUASs       PerfIntervalCount,
    cSdslSturIntervalValidData  TruthValue
}

cSdslSturIntervalNumber OBJECT-TYPE
    SYNTAX      Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The interval in which the statistics were collected, where the
        value of 1 represents the most recent interval, and the value of
        96 represents the interval collected 24 hours ago.  Intervals
        2..96 are optional."
    ::= { cSdslSturIntervalEntry 1 }

cSdslSturIntervalValidData OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies whether the data for this interval
        is valid."
    ::= { cSdslSturIntervalEntry 2 }

cSdslSturIntervalLOSs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the interval
        when the STU-R experienced LOS."
    ::= { cSdslSturIntervalEntry 3 }

cSdslSturIntervalLOSQs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of seconds in the interval
        when the STU-R experienced LOSQ."
    ::= { cSdslSturIntervalEntry 4 }

cSdslSturIntervalCVs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of coding violations
        experienced by the STU-R in the interval."
    ::= { cSdslSturIntervalEntry 5 }

cSdslSturIntervalESs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of errored seconds
        experienced by the STU-R in the interval."
    ::= { cSdslSturIntervalEntry 6 }

cSdslSturIntervalSESs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of severely errored seconds
        experienced by the STU-R in the interval."
    ::= { cSdslSturIntervalEntry 7 }

cSdslSturIntervalUASs OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object specifies the number of unavailable seconds
        experienced by the STU-R in the interval."
    ::= { cSdslSturIntervalEntry 8 }

-- SDSL Line Configuration Profile Table

cSdslLineConfProfileTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslLineConfProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table extends the adslLineConfProfileTable and contains
        enterprise-specific SDSL line configuration information."
    ::= { ciscoSdslLineMIBObjects 14 }

cSdslLineConfProfileEntry OBJECT-TYPE
    SYNTAX      CSdslLineConfProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A configuration profile containing enterprise-specific SDSL
        line configuration information."
    INDEX       { IMPLIED adslLineConfProfileName }
    ::= { cSdslLineConfProfileTable 1 }

CSdslLineConfProfileEntry ::= SEQUENCE {
     cSdslLineMaxRate      Integer32,
     cSdslLineFramingMode  INTEGER,
     cSdslStucTargetSnrMgn Integer32,
     cSdslStucMaxSnrMgn    Integer32,
     cSdslStucMinSnrMgn    Integer32,
     cSdslStucOutputPwr    Integer32,
     cSdslShdslLineMaxRate INTEGER,
     cSdslStucPsdMaskType  INTEGER,
     cSdslStucAnnex        INTEGER,
     cSdslLineEquipmentType INTEGER,
     cSdslLineAutoRateEnable TruthValue,
     cSdslStucThresholdSnrMgn Integer32,
     cSdslSturAnnex        INTEGER
}

cSdslLineMaxRate OBJECT-TYPE
    SYNTAX      Integer32 (144000 |
                           272000 |
                           400000 |
                           528000 |
                           784000 |
                          1040000 |
                          1168000 |
                          1552000 |
                          2064000 |
                          2320000 )
    UNITS       "bps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the desired line rate which the STU-C
        will attempt to train at."
    DEFVAL      { 784000 }
    ::= { cSdslLineConfProfileEntry 1 }

cSdslLineFramingMode OBJECT-TYPE
    SYNTAX      INTEGER {
        none(1),            -- no frame format
        other(2),           --
        hdsl(3),            -- HDSL frame format for SDSL interaces
        gShdsl(4),          -- G.SHDSL frame format for G.SHDSL
        hdsl2(5),           -- HDSL2 frame format for HDSL2 interfaces
        ds1(6)              -- DS1 frame format for HDSL2 interfaces
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the desired Transmission Convergence
        framing structure being used by the interface."
    ::= { cSdslLineConfProfileEntry 2 }


cSdslStucTargetSnrMgn OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dB"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the target SNR margin.  This is the
        desired noise margin the STU-C must achieve with a BER of
        10-7 or better to successfully complete training. The value
        for this object must be in multiples of 10. The specified
        value will be rounded down to the nearest valid tenth dB
        level if the value is not in multiples of 10."
    DEFVAL      { 0 }
    ::= { cSdslLineConfProfileEntry 3 }

cSdslStucMaxSnrMgn OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dB"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the maximum acceptable SNR margin.
        If the noise margin exceeds this level, then the STU-C should
        attempt to reduce its power output to optimize its operation.
        The value for this object must be in multiples of 10. The
        specified value will be rounded down to the nearest valid
        tenth dB level if the value is not in multiples of 10."
    DEFVAL      { 90 }
    ::= { cSdslLineConfProfileEntry 4 }

cSdslStucMinSnrMgn OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dB"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the minimum acceptable SNR margin.
        If the noise margin falls below this level, the STU-C will
        retrain. The value for this object must be in multiples of 10.
        The specified value will be rounded down to the nearest valid
        tenth dB level if the value is not in multiples of 10."
    DEFVAL      { 0 }
    ::= { cSdslLineConfProfileEntry 5 }

cSdslStucOutputPwr OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dBm"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the transmit power level used by
        the STU-C. The value for this object must be in multiples
        of 10. The specified value will be rounded down to the
        nearest valid tenth dB level if the value is not in
        multiples of 10."
    DEFVAL      { 130 }
    ::= { cSdslLineConfProfileEntry 6 }

cSdslShdslLineMaxRate OBJECT-TYPE
    SYNTAX      INTEGER { r2376000(2376000),
                          r2312000(2312000),
                          r2056000(2056000),
                          r1552000(1552000),
                          r1544000(1544000),
                          r1160000(1160000),
                          r1032000(1032000),
                           r784000(784000),
                           r776000(776000),
                           r520000(520000),
                           r392000(392000),
                           r264000(264000),
                           r200000(200000),
                           r136000(136000),
                            r72000(72000) }
    UNITS       "bps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the desired line rate at which the
        G.shdsl STU-C will attempt to train."
    REFERENCE
        "ITU Draft G.Shdsl, Single-Pair High Speed Digital Subscriber
         Line(SHDSL) Transceivers"
    DEFVAL      { r776000 }
    ::= { cSdslLineConfProfileEntry 7 }

cSdslStucPsdMaskType OBJECT-TYPE
    SYNTAX      INTEGER {
        symmetric(1),
        asymmetric(2)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the PSD mask type for the transceiver.
        For all values of the cSdslShdslLineMaxRate, the symmetric PSD
        masktype is selectable. Asymmetric mask is only selectable for
        the following rates: 776000, 784000, 1552000, 2056000, 2312000."
    DEFVAL      { symmetric }
    ::= { cSdslLineConfProfileEntry 8 }

cSdslStucAnnex OBJECT-TYPE
    SYNTAX      INTEGER {
        annexA(1),
        annexB(2)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the operating conditions for the port
         of G.shdsl CO equipment . Annex A is optimized for conditions
        typically encountered within the North American network,whereas
        Annex B is optimized for conditions typically encountered
        within the European network."
    DEFVAL      { annexA }
    ::= { cSdslLineConfProfileEntry 9 }

cSdslLineEquipmentType     OBJECT-TYPE
    SYNTAX      INTEGER {
        stuR(1),
        stuC(2)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the type of the STU device ,either
        STU-C or STU-R"
    DEFVAL      { stuR }
    ::= { cSdslLineConfProfileEntry 10 }

cSdslLineAutoRateEnable OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies whether the device uses the rate
        adaptive training mode."
    DEFVAL      { false }
    ::= { cSdslLineConfProfileEntry 11 }

cSdslStucThresholdSnrMgn OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dB"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the SNR margin threshold.  An
        appropriate alarm should be generated when the difference
        between the actual SNR and the SNR required to maintain BER
        of 10E-7 is less than this value. The value for this object
        must be in multiples of 10. The specified value will be
        rounded down to the nearest valid tenth dB level if the
        value is not in multiples of 10.

        If the agent implements the CISCO-ENTITY-ALARM-MIB, the alarm
        generated should be through the mechanism defined by the
        CISCO-ENTITY-ALARM-MIB. Furthermore, the default severity
        of this alarm should be 'minor'."
    DEFVAL      { 30 }
    ::= { cSdslLineConfProfileEntry 12 }

cSdslSturAnnex OBJECT-TYPE
    SYNTAX      INTEGER {
        annexA(1),
        annexB(2)
    }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the operating conditions for the port
        of G.shdsl CPE equipment. Annex A is optimized for conditions
        typically encountered within the North American network,whereas
        Annex B is optimized for conditions typically encountered
        within the European network."
    DEFVAL      { annexA }
    ::= { cSdslLineConfProfileEntry 13 }

-- Alarm Configuration Profile Table

cSdslLineAlarmConfProfileTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CSdslLineAlarmConfProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table extends the adslLineAlarmConfProfileTable and
        contains enterprise-specific SDSL line configuration information
        pertaining to alarms."
    ::= { ciscoSdslLineMIBObjects 15 }

cSdslLineAlarmConfProfileEntry OBJECT-TYPE
    SYNTAX      CSdslLineAlarmConfProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A configuration profile containing enterprise-specific SDSL
        line configuration information pertaining to alarms"
    INDEX       { IMPLIED adslLineAlarmConfProfileName }
    ::= { cSdslLineAlarmConfProfileTable 1 }

CSdslLineAlarmConfProfileEntry ::= SEQUENCE {
    cSdslStucThreshMinRate   Integer32,
    cSdslStucThreshMinSnrMgn Integer32
}

cSdslStucThreshMinRate OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "bps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the line rate threshold.  When the
        agent observes the line rate fall below this value, an
        appropriate alarm should be generated.

        The default value for this object should be the value of
        the cSdslLineMaxRate object.

        If the agent implements the CISCO-ENTITY-ALARM-MIB, the
        alarm generated should be through the mechanism defined by
        the CISCO-ENTITY-ALARM-MIB.  Furthermore, the default
        severity of this alarm should be 'minor'."
    ::= { cSdslLineAlarmConfProfileEntry 1 }

cSdslStucThreshMinSnrMgn OBJECT-TYPE
    SYNTAX      Integer32 (0..310)
    UNITS       "tenth dB"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the SNR margin threshold.  When the
        agent observes the received SNR margin fall below this value,
        an appropriate alarm should be generated.

        If the agent implements the CISCO-ENTITY-ALARM-MIB, the alarm
        generated should be through the mechanism defined by the
        CISCO-ENTITY-ALARM-MIB.  Furthermore, the default severity
        of this alarm should be 'minor'."
    DEFVAL      { 30 }
    ::= { cSdslLineAlarmConfProfileEntry 2 }

-- MIB Notification Definitions

ciscoSdslLineMIBNotificationsPrefix OBJECT IDENTIFIER ::=
    { ciscoSdslLineMIB 2 }

ciscoSdslLineMIBNotifications       OBJECT IDENTIFIER ::=
    { ciscoSdslLineMIBNotificationsPrefix 0 }

-- MIB Conformance Statements

ciscoSdslLineMIBConformance OBJECT IDENTIFIER ::=
    { ciscoSdslLineMIB 3 }

ciscoSdslLineMIBCompliances OBJECT IDENTIFIER ::=
    { ciscoSdslLineMIBConformance 1 }

ciscoSdslLineMIBGroups      OBJECT IDENTIFIER ::=
    { ciscoSdslLineMIBConformance 2 }

-- Compliance

ciscoSdslLineMIBStucCompliance MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
        "The compliance statement for entities that implement the
        CISCO-SDSL-LINE-MIB.  Implementation of this MIB is mandatory
        for any platform that supports one or more SDSL line
        interfaces. This specification is replaced by
        ciscoSdslLineMIBStucComplianceRev1"

    MODULE -- this module
        MANDATORY-GROUPS {
            cSdslStucBasicGroup,
            cSdslStucPMCounterGroup
        }

        GROUP       cSdslStucRateAdaptiveGroup
        DESCRIPTION
            "The implementation of this group is optional.  However,
            this statement recommends the implementation of this group
            if the STU-C supports rate adaptation."

        GROUP       cSdslSturGroup
        DESCRIPTION
            "The implementation of this group is optional.  However,
            this statement recommends the implementation of this group
            if the STU-C and STU-R support a remote management
            capability."

        GROUP       cSdslStucPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslStucPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPMCounterGroup
        DESCRIPTION
            "The implementation of this group is optional. However,
            this statement recommends the implementation of this group
            if the STU-C and STU-R support a remote management
            capability."

        GROUP       cSdslSturPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslStucAlarmConfProfileGroup
        DESCRIPTION
            "The implementation of this group is optional.  If the agent
            implements the CISCO-ENTITY-ALARM-MIB, then this statement
            strongly discourages the implementation of this group.
            Rather the agent should define alarm types for physical
            entities of the cevPortSdsl2b1q vendor type corresponding
            to the conditions described by cSdslStucThreshMinRate
            and cSdslStucThreshMinSnrMgn."

        OBJECT      cSdslLineConfProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-only access is applicable only when implementing
            static profiles."

        OBJECT      cSdslLineAlarmConfProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-only access is applicable only when implementing
            static profiles."

        OBJECT      cSdslStucThreshMinRate
        MIN-ACCESS  read-write
        DESCRIPTION
            "Read-write access is application when implementing static
            profiles."

        OBJECT      cSdslStucThreshMinSnrMgn
        MIN-ACCESS  read-write
        DESCRIPTION
            "Read-write access is application when implementing static
            profiles."

    ::= { ciscoSdslLineMIBCompliances 1 }

ciscoSdslLineMIBSturCompliance MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
        "The compliance statement for entities that implement the
        CISCO-SDSL-LINE-MIB and manage SDSL STU-R class devices.
        Implementation of this MIB is mandatory for any platform
        that supports one or more SDSL line interfaces. This
        specification is replaced by
        ciscoSdslLineMIBSturComplianceRev1."

    MODULE -- this module
        MANDATORY-GROUPS {
            cSdslSturBasicGroup,
            cSdslSturPMCounterGroup
        }

        GROUP       cSdslSturPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

    ::= { ciscoSdslLineMIBCompliances 2 }

ciscoSdslLineMIBStucComplianceRev1 MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
        "The compliance statement for entities that implement the
        CISCO-SDSL-LINE-MIB.  Implementation of this MIB is mandatory
        for any platform that supports one or more SDSL line
        interfaces."

    MODULE -- this module
        MANDATORY-GROUPS {
            cSdslStucBasicGroupRev1,
            cSdslStucPMCounterGroup
        }

        GROUP       cSdslStucRateAdaptiveGroup
        DESCRIPTION
            "The implementation of this group is optional.  However,
            this statement recommends the implementation of this group
            if the STU-C supports rate adaptation."

        GROUP       cSdslSturGroup
        DESCRIPTION
            "The implementation of this group is optional.  However,
            this statement recommends the implementation of this group
            if the STU-C and STU-R support a remote management
            capability."

        GROUP       cSdslStucPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslStucPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPMCounterGroup
        DESCRIPTION
            "The implementation of this group is optional. However,
            this statement recommends the implementation of this group
            if the STU-C and STU-R support a remote management
            capability."

        GROUP       cSdslSturPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslStucAlarmConfProfileGroup
        DESCRIPTION
            "The implementation of this group is optional.  If the agent
            implements the CISCO-ENTITY-ALARM-MIB, then this statement
            strongly discourages the implementation of this group.
            Rather the agent should define alarm types for physical
            entities of the cevPortSdsl2b1q vendor type corresponding
            to the conditions described by cSdslStucThreshMinRate
            and cSdslStucThreshMinSnrMgn."

        OBJECT      cSdslLineConfProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-only access is applicable only when implementing
            static profiles."

        OBJECT      cSdslLineAlarmConfProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-only access is applicable only when implementing
            static profiles."

        OBJECT      cSdslStucThreshMinRate
        MIN-ACCESS  read-write
        DESCRIPTION
            "Read-write access is application when implementing static
            profiles."

        OBJECT      cSdslStucThreshMinSnrMgn
        MIN-ACCESS  read-write
        DESCRIPTION
            "Read-write access is application when implementing static
            profiles."

    ::= { ciscoSdslLineMIBCompliances 3 }

ciscoSdslLineMIBSturComplianceRev1 MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
        "The compliance statement for entities that implement the
        CISCO-SDSL-LINE-MIB and manage SDSL STU-R class devices.
        Implementation of this MIB is mandatory for any platform
        that supports one or more SDSL line interfaces."

    MODULE -- this module
        MANDATORY-GROUPS {
            cSdslSturBasicGroupRev1,
            cSdslSturPMCounterGroup
        }

        GROUP       cSdslSturPM15MinIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

        GROUP       cSdslSturPM1DayIntervalGroup
        DESCRIPTION
            "The implementation of this group is optional."

    ::= { ciscoSdslLineMIBCompliances 4 }

-- Units of Conformance

cSdslStucBasicGroup OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslLineSpecific,
        cSdslLineConfProfile,
        cSdslLineAlarmConfProfile,
        cSdslStucInvSerialNumber,
        cSdslStucInvVendorId,
        cSdslStucInvVersionNumber,
        cSdslStucState,
        cSdslStucDefect,
        cSdslStucCurrRate,
        cSdslStucCurrSnrMgn,
        cSdslStucCurrGain,
        cSdslStucCurrOutputPwr,
        cSdslStucCurrAtn,
        cSdslLineMaxRate,
        cSdslLineFramingMode,
        cSdslStucTargetSnrMgn,
        cSdslStucOutputPwr
    }
    STATUS deprecated
    DESCRIPTION
        "A collection of managed objects defining the basic operation
        of an STU-C (i.e., no rate adaptation). This specification
        is replaced by cSdslStucBasicGroupRev1."
    ::= { ciscoSdslLineMIBGroups 1 }

cSdslSturBasicGroup OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslLineSpecific,
        cSdslSturInvSerialNumber,
        cSdslSturInvVendorId,
        cSdslSturInvVersionNumber,
        cSdslSturState,
        cSdslSturDefect,
        cSdslSturCurrRate,
        cSdslSturCurrSnrMgn,
        cSdslSturCurrGain,
        cSdslSturCurrOutputPwr,
        cSdslSturCurrAtn
    }
    STATUS deprecated
    DESCRIPTION
        "A collection of managed objects defining the basic operation
 of an STU-R.This specification is replaced by cSdslSturBasicGroupRev1"
    ::= { ciscoSdslLineMIBGroups 2 }

cSdslSturGroup OBJECT-GROUP
    OBJECTS {
        cSdslSturInvSerialNumber,
        cSdslSturInvVendorId,
        cSdslSturInvVersionNumber,
        cSdslSturState,
        cSdslSturDefect,
        cSdslSturCurrRate,
        cSdslSturCurrSnrMgn,
        cSdslSturCurrGain,
        cSdslSturCurrOutputPwr
    }
    STATUS deprecated
    DESCRIPTION
        "A collection of managed objects defining the capability to
        remotely manage a STU-R. This is replaced by cSdslSturGroupRev1."
    ::= { ciscoSdslLineMIBGroups 3 }

cSdslStucPMCounterGroup OBJECT-GROUP
    OBJECTS {
        cSdslStucPerfLOSs,
        cSdslStucPerfLOSQs,
        cSdslStucPerfCVs,
        cSdslStucPerfESs,
        cSdslStucPerfSESs,
        cSdslStucPerfUASs,
        cSdslStucPerfInits,
        cSdslStucUnavailRsrcs
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining basic near-end
        performance monitoring capability."
    ::= { ciscoSdslLineMIBGroups 4 }

cSdslStucPM15MinIntervalGroup OBJECT-GROUP
    OBJECTS {
        cSdslStucPerfValidIntervals,
        cSdslStucPerfInvalidIntervals,
        cSdslStucPerfCurr15MinTimeElapse,
        cSdslStucPerfCurr15MinLOSs,
        cSdslStucPerfCurr15MinLOSQs,
        cSdslStucPerfCurr15MinCVs,
        cSdslStucPerfCurr15MinESs,
        cSdslStucPerfCurr15MinSESs,
        cSdslStucPerfCurr15MinUASs,
        cSdslStucPerfCurr15MinInits,
        cSdslStucPerfCurr15MinUnavlRsrcs,
        cSdslStucIntervalValidData,
        cSdslStucIntervalLOSs,
        cSdslStucIntervalLOSQs,
        cSdslStucIntervalCVs,
        cSdslStucIntervalESs,
        cSdslStucIntervalSESs,
        cSdslStucIntervalUASs,
        cSdslStucIntervalInits,
        cSdslStucIntervalUnavlRsrcs
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining near-end performance
        data collection capability using 15-minute intervals."
    ::= { ciscoSdslLineMIBGroups 5 }

cSdslStucPM1DayIntervalGroup OBJECT-GROUP
    OBJECTS {
        cSdslStucPerfCurr1DayTimeElapsed,
        cSdslStucPerfCurr1DayLOSs,
        cSdslStucPerfCurr1DayLOSQs,
        cSdslStucPerfCurr1DayCVs,
        cSdslStucPerfCurr1DayESs,
        cSdslStucPerfCurr1DaySESs,
        cSdslStucPerfCurr1DayUASs,
        cSdslStucPerfCurr1DayInits,
        cSdslStucPerfCurr1DayUnavlRsrcs,
        cSdslStucPerfPrev1DayMoniSecs,
        cSdslStucPerfPrev1DayLOSs,
        cSdslStucPerfPrev1DayLOSQs,
        cSdslStucPerfPrev1DayCVs,
        cSdslStucPerfPrev1DayESs,
        cSdslStucPerfPrev1DaySESs,
        cSdslStucPerfPrev1DayUASs,
        cSdslStucPerfPrev1DayInits,
        cSdslStucPerfPrev1DayUnavlRsrcs
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining near-end performance
        data collection capability using 1-day intervals."
    ::= { ciscoSdslLineMIBGroups 6 }

cSdslSturPMCounterGroup OBJECT-GROUP
    OBJECTS {
        cSdslSturPerfLOSs,
        cSdslSturPerfLOSQs,
        cSdslSturPerfCVs,
        cSdslSturPerfESs,
        cSdslSturPerfSESs,
        cSdslSturPerfUASs
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining basic far-end
        performance monitoring capability."
    ::= { ciscoSdslLineMIBGroups 7 }

cSdslSturPM15MinIntervalGroup OBJECT-GROUP
    OBJECTS {
        cSdslSturPerfValidIntervals,
        cSdslSturPerfInvalidIntervals,
        cSdslSturPerfCurr15MinTimeElapse,
        cSdslSturPerfCurr15MinLOSs,
        cSdslSturPerfCurr15MinLOSQs,
        cSdslSturPerfCurr15MinCVs,
        cSdslSturPerfCurr15MinESs,
        cSdslSturPerfCurr15MinSESs,
        cSdslSturPerfCurr15MinUASs,
        cSdslSturIntervalLOSs,
        cSdslSturIntervalLOSQs,
        cSdslSturIntervalCVs,
        cSdslSturIntervalESs,
        cSdslSturIntervalSESs,
        cSdslSturIntervalUASs,
        cSdslSturIntervalValidData
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining far-end performance
        data collection capability using 15-minute intervals."
    ::= { ciscoSdslLineMIBGroups 8 }

cSdslSturPM1DayIntervalGroup OBJECT-GROUP
    OBJECTS {
        cSdslSturPerfCurr1DayTimeElapsed,
        cSdslSturPerfCurr1DayLOSs,
        cSdslSturPerfCurr1DayLOSQs,
        cSdslSturPerfCurr1DayCVs,
        cSdslSturPerfCurr1DayESs,
        cSdslSturPerfCurr1DaySESs,
        cSdslSturPerfCurr1DayUASs,
        cSdslSturPerfPrev1DayMoniSecs,
        cSdslSturPerfPrev1DayLOSs,
        cSdslSturPerfPrev1DayLOSQs,
        cSdslSturPerfPrev1DayCVs,
        cSdslSturPerfPrev1DayESs,
        cSdslSturPerfPrev1DaySESs,
        cSdslSturPerfPrev1DayUASs
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining far-end performance
        data collection capability using 1-day intervals."
    ::= { ciscoSdslLineMIBGroups 9 }

cSdslStucRateAdaptiveGroup OBJECT-GROUP
    OBJECTS {
        cSdslStucCurrRate,
        cSdslStucMaxSnrMgn,
        cSdslStucMinSnrMgn,
        cSdslStucThreshMinRate
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining rate adaptive
        operation of an STU-C."
    ::= { ciscoSdslLineMIBGroups 10 }

cSdslStucAlarmConfProfileGroup OBJECT-GROUP
    OBJECTS {
        cSdslStucThreshMinRate,
        cSdslStucThreshMinSnrMgn
    }
    STATUS current
    DESCRIPTION
        "A collection of traps generated by the agent to signal
        threshold alarms."
    ::= { ciscoSdslLineMIBGroups 11 }

cSdslStucBasicGroupRev1 OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslLineSpecific,
        cSdslLineConfProfile,
        cSdslLineAlarmConfProfile,
        cSdslStucInvSerialNumber,
        cSdslStucInvVendorId,
        cSdslStucInvVersionNumber,
        cSdslStucState,
        cSdslStucDefect,
        cSdslStucCurrRate,
        cSdslStucCurrSnrMgn,
        cSdslStucCurrGain,
        cSdslStucCurrOutputPwr,
        cSdslStucCurrAtn,
        cSdslLineMaxRate,
        cSdslLineFramingMode,
        cSdslStucTargetSnrMgn,
        cSdslStucMaxSnrMgn,
        cSdslStucMinSnrMgn,
        cSdslStucOutputPwr,
        cSdslShdslLineMaxRate,
        cSdslStucPsdMaskType,
        cSdslStucAnnex,
        cSdslLineEquipmentType,
        cSdslLineAutoRateEnable,
        cSdslStucThresholdSnrMgn
    }
    STATUS deprecated
    DESCRIPTION
        "A collection of managed objects defining the basic operation
        of an STU-C. This specification is replaced by
        cSdslStucBasicGroupRev2."
    ::= { ciscoSdslLineMIBGroups 12 }

cSdslSturBasicGroupRev1 OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslSturInvSerialNumber,
        cSdslSturInvVendorId,
        cSdslSturInvVersionNumber,
        cSdslSturState,
        cSdslSturDefect,
        cSdslSturCurrRate,
        cSdslSturCurrSnrMgn,
        cSdslSturCurrGain,
        cSdslSturCurrOutputPwr,
        cSdslSturCurrAtn,
        cSdslShdslLineMaxRate,
        cSdslLineEquipmentType,
        cSdslLineAutoRateEnable,
        cSdslSturAnnex
    }
    STATUS deprecated
    DESCRIPTION
        "A collection of managed objects defining the basic operation
        of an STU-R. This specification is replaced by
        cSdslSturBasicGroupRev2"
    ::= { ciscoSdslLineMIBGroups 13 }

cSdslStucBasicGroupRev2 OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslLineSpecific,
        cSdslLineConfProfile,
        cSdslLineAlarmConfProfile,
        cSdslStucInvSerialNumber,
        cSdslStucInvVendorId,
        cSdslStucInvVersionNumber,
        cSdslStucState,
        cSdslStucDefect,
        cSdslStucCurrRate,
        cSdslStucCurrSnrMgn,
        cSdslStucCurrGainRev,
        cSdslStucCurrOutputPwr,
        cSdslStucCurrAtn,
        cSdslLineMaxRate,
        cSdslLineFramingMode,
        cSdslStucTargetSnrMgn,
        cSdslStucMaxSnrMgn,
        cSdslStucMinSnrMgn,
        cSdslStucOutputPwr,
        cSdslShdslLineMaxRate,
        cSdslStucPsdMaskType,
        cSdslStucAnnex,
        cSdslLineEquipmentType,
        cSdslLineAutoRateEnable,
        cSdslStucThresholdSnrMgn
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining the basic operation
        of an STU-C."
    ::= { ciscoSdslLineMIBGroups 14 }

cSdslSturBasicGroupRev2 OBJECT-GROUP
    OBJECTS {
        cSdslLineCoding,
        cSdslLineFraming,
        cSdslSturInvSerialNumber,
        cSdslSturInvVendorId,
        cSdslSturInvVersionNumber,
        cSdslSturState,
        cSdslSturDefect,
        cSdslSturCurrRate,
        cSdslSturCurrSnrMgn,
        cSdslSturCurrGainRev,
        cSdslSturCurrOutputPwr,
        cSdslSturCurrAtn,
        cSdslShdslLineMaxRate,
        cSdslLineEquipmentType,
        cSdslLineAutoRateEnable,
        cSdslSturAnnex
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining the basic operation
        of an STU-R."
    ::= { ciscoSdslLineMIBGroups 15 }

cSdslSturGroupRev1 OBJECT-GROUP
    OBJECTS {
        cSdslSturInvSerialNumber,
        cSdslSturInvVendorId,
        cSdslSturInvVersionNumber,
        cSdslSturState,
        cSdslSturDefect,
        cSdslSturCurrRate,
        cSdslSturCurrSnrMgn,
        cSdslSturCurrGainRev,
        cSdslSturCurrOutputPwr
    }
    STATUS current
    DESCRIPTION
        "A collection of managed objects defining the capability to
        remotely manage a STU-R."
    ::= { ciscoSdslLineMIBGroups 16 }

END