CISCO-SNA-LLC-MIB device MIB details by Cisco
CISCO-SNA-LLC-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-SNA-LLC-MIB.
Vendor: | Cisco |
---|---|
Mib: | CISCO-SNA-LLC-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- ***************************************************************** -- CISCO-SNA-LLC-MIB - SNA Logical Link Control MIB. -- -- April 1995, Mike Otto -- -- Copyright (c) 1995-1996 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** -- CISCO-SNA-LLC-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter32, Integer32, TimeTicks, Gauge32 FROM SNMPv2-SMI DisplayString, RowStatus, TimeStamp, MacAddress FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM RFC1213-MIB ciscoExperiment FROM CISCO-SMI; ciscoSnaLlcMIB MODULE-IDENTITY LAST-UPDATED "9505100000Z" ORGANIZATION "cisco IBM engineering Working Group" CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com" DESCRIPTION "This is the MIB module for objects used to manage LLC devices." REVISION "9505100000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoExperiment 8 } -- -- The following data link controls are modeled in this MIB module: -- -- 1. LLC -- ciscoSnaLlcMIBObjects OBJECT IDENTIFIER ::= { ciscoSnaLlcMIB 1 } -- -- THE LLC GROUP -- ============= -- -- The following resources are modeled in the LLC group of this MIB: -- -- 1. Ports -- 2. Service Access Points (SAP) -- 3. Connection Components (CC) llcPortGroup OBJECT IDENTIFIER ::= { ciscoSnaLlcMIBObjects 1 } llcSapGroup OBJECT IDENTIFIER ::= { ciscoSnaLlcMIBObjects 2 } llcCcGroup OBJECT IDENTIFIER ::= { ciscoSnaLlcMIBObjects 3 } -- -- THE LLC PORT GROUP -- ================== -- -- The following classes of information are modeled for each LLC port: -- -- 1. ADMINISTRATIVE ( read/write) -- 2. OPERATIONAL ( read-only) -- 3. STATISTICS ( read-only) -- Information not found in this group is found in tables described in -- the following RFCs: -- -- 1. RFC1213 - MIB-II -- -- TABLE INDEX -- ==================== ==================== -- a. ifTable ifIndex -- -- ************************************************************* -- * * -- * THE LLC PORT ADMINISTRATIVE TABLE * -- * * -- ************************************************************* llcPortAdminTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcPortAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects that can be changed to manage an LLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation." ::= { llcPortGroup 1 } llcPortAdminEntry OBJECT-TYPE SYNTAX LlcPortAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of configured values for an LLC port." INDEX { ifIndex, llcPortVirtualIndex } ::= { llcPortAdminTable 1 } LlcPortAdminEntry ::= SEQUENCE { llcPortVirtualIndex Integer32, llcPortAdminName DisplayString, llcPortAdminMaxSaps Gauge32, llcPortAdminMaxCcs Gauge32, llcPortAdminMaxPDUOctets Integer32, llcPortAdminMaxUnackedIPDUsSend INTEGER, llcPortAdminMaxUnackedIPDUsRcv INTEGER, llcPortAdminMaxRetransmits Integer32, llcPortAdminAckTimer TimeTicks, llcPortAdminPbitTimer TimeTicks, llcPortAdminRejTimer TimeTicks, llcPortAdminBusyTimer TimeTicks, llcPortAdminInactTimer TimeTicks, llcPortAdminDelayAckCount Integer32, llcPortAdminDelayAckTimer TimeTicks, llcPortAdminNw Integer32 } llcPortVirtualIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value represents a virtual LLC port. It is assigned by the agent. This value is set to 0 by the agent for interfaces identified by the ifIndex value that do not support virtual interfaces." ::= { llcPortAdminEntry 1 } llcPortAdminName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "An octet string that defines the virtual port to which this interface is assigned. Its value shall be unique within the administered system. It must contain only ASCII printable characters. A write operation shall not take effect until the port is cycled inactive." ::= { llcPortAdminEntry 2 } llcPortAdminMaxSaps OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the maximum number of SAPs that can be defined for this port." ::= { llcPortAdminEntry 3 } llcPortAdminMaxCcs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the maximum number of connection components that can be administratively defined for this port." ::= { llcPortAdminEntry 4 } llcPortAdminMaxPDUOctets OBJECT-TYPE SYNTAX Integer32 UNITS "octets" MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum I PDU size, in octets, that LLCs on this port may send to their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsSend object or by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.3 Maximum Number of Octets in an I PDU, N1." ::= { llcPortAdminEntry 5 } llcPortAdminMaxUnackedIPDUsSend OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this port may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsSend object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.4 Maximum Number of Outstanding I PDUs, k." DEFVAL { 2 } ::= { llcPortAdminEntry 6 } llcPortAdminMaxUnackedIPDUsRcv OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsRcv object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.4 Maximum Number of Outstanding I PDUs, k." DEFVAL { 2 } ::= { llcPortAdminEntry 7 } llcPortAdminMaxRetransmits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the maximum number of times which LLCs on this port shall retry a PDU following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxretransmits object or by a non-zero value in the llcCcAdminMaxRetransmits object." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.2 Maximum Number of Transmissions, N2." DEFVAL { 2 } ::= { llcPortAdminEntry 8 } llcPortAdminAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the unacknowledged frames to be retransmitted (up to N2 times). For Implementations that only use a single 'T1' Value (ref. IBM Token-Ring Network technical reference Chapter 11). This object will be used to control/read the value. This port default value may be overridden by a non-zero value in the llcSapAdminAckTimer object or by a non-zero value in the llcCcAdminAckTimer object." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.1.1 Acknowledgment Timer" DEFVAL { 300 } ::= { llcPortAdminEntry 9 } llcPortAdminPbitTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the command with the poll bit to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminPbitTimer object or by a non-zero value in the llcCcAdminPbitTimer object." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.1.2 P-Bit Timer" DEFVAL { 300 } ::= { llcPortAdminEntry 10 } llcPortAdminRejTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminRejTimer object or by a non-zero value in the llcCcAdminRejTimer object." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.1.3 Reject Timer" DEFVAL { 300 } ::= { llcPortAdminEntry 11 } llcPortAdminBusyTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminBusyTimer object or by a non-zero value in the llcCcAdminBusyTimer object." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.8.1.4 Busy-State Timer" DEFVAL { 30000 } ::= { llcPortAdminEntry 12 } llcPortAdminInactTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture [6] Reference as the Ti parameter and is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. The value for llcPortAdminInactTimer must be much greater than the value for llcPortAdminDelayAckTimer. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminInactTimer object or by a non-zero value in the llcCcAdminInactTimer object. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Inactivity Timer (Ti)" DEFVAL { 3000 } ::= { llcPortAdminEntry 13 } llcPortAdminDelayAckCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this port shall receive during the interval defined by llcCcOperDelayTimertime without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the N3 parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminDelayAckCount object or by a non-zero value in the llcCcAdminDelayCount object. A value of one indicates that acknowledgments will be sent immediately and that the value of llcPortAdminDelayAckTimer shall be ignored." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Number of I-Format LPDUs Received before Sending Acknowledgment (N3)" DEFVAL { 1 } ::= { llcPortAdminEntry 14 } llcPortAdminDelayAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Receiver Acknowledgment Timer (T2)" DEFVAL { 100 } ::= { llcPortAdminEntry 15 } llcPortAdminNw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminNw object." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Number of Acknowledgments Needed to Increment Ww (Nw)" DEFVAL { 4 } ::= { llcPortAdminEntry 16 } -- ************************************************************* -- * * -- * THE LLC PORT OPERATIONAL TABLE * -- * * -- ************************************************************* llcPortOperTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains current LLC port parameters. Many of these objects have corresponding objects in the llcPortAdminTable." ::= { llcPortGroup 2 } llcPortOperEntry OBJECT-TYPE SYNTAX LlcPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Currently set parameters for a specific LLC port." INDEX { ifIndex, llcPortVirtualIndex } ::= { llcPortOperTable 1 } LlcPortOperEntry ::= SEQUENCE { llcPortOperMacAddress MacAddress, llcPortOperNumSaps Gauge32, llcPortOperHiWaterNumSaps Gauge32, llcPortOperSimRim INTEGER, llcPortOperLastModifyTime TimeStamp } llcPortOperMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the MAC Address for this local port." ::= { llcPortOperEntry 1 } llcPortOperNumSaps OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the number of SAPs on this port that are currently enabled. In other words, this object is a count of the number of instances of llcSapOperEntry that have a llcSapOperStatus value of 'active(2)'." ::= { llcPortOperEntry 2 } llcPortOperHiWaterNumSaps OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the highest number of SAPs active on this Port simultaneously. In other words, this object is a count of the number of instances of llcSapOperEntry on this Port." ::= { llcPortOperEntry 3 } llcPortOperSimRim OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects support for transmission and receipt of SIM and RIM control frames for this port. SIM and RIM are not defined in the ANSI/IEEE 802.2 specification [5] nor in the IBM Token Ring Architecture Reference [6]. These control frames are used for the remote program load of IBM communications processors." DEFVAL { no } ::= { llcPortOperEntry 4 } llcPortOperLastModifyTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero." ::= { llcPortOperEntry 5 } -- ************************************************************* -- * * -- * THE LLC PORT STATISTICS TABLE * -- * * -- ************************************************************* llcPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table contains statistics for a specific LLC port." ::= { llcPortGroup 3 } llcPortStatsEntry OBJECT-TYPE SYNTAX LlcPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of statistics for an LLC port." INDEX { ifIndex, llcPortVirtualIndex } ::= { llcPortStatsTable 1 } LlcPortStatsEntry ::= SEQUENCE { llcPortStatsPDUsIn Counter32, llcPortStatsPDUsOut Counter32, llcPortStatsOctetsIn Counter32, llcPortStatsOctetsOut Counter32, llcPortStatsTESTCommandsIn Counter32, llcPortStatsTESTResponsesOut Counter32, llcPortStatsLocalBusies Counter32, llcPortStatsUnknownSaps Counter32 } llcPortStatsPDUsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of PDUs that have been received on this port. This object is initialized to zero when the port is created." ::= { llcPortStatsEntry 1 } llcPortStatsPDUsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of PDUs that have been transmitted on this port. This object is initialized to zero when the port is created." ::= { llcPortStatsEntry 2 } llcPortStatsOctetsIn OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets received on this port. This object is initialized to zero when the port is created." ::= { llcPortStatsEntry 3 } llcPortStatsOctetsOut OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets transmitted on this port. This object is initialized to zero when the port is created." ::= { llcPortStatsEntry 4 } llcPortStatsTESTCommandsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of TEST commands received on this port." ::= { llcPortStatsEntry 5 } llcPortStatsTESTResponsesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of TEST responses transmitted on this port in response to TEST commands received." ::= { llcPortStatsEntry 6 } llcPortStatsLocalBusies OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that the local connection components on this port have entered a busy state (RNR). This object is initialized to zero when the port is created." ::= { llcPortStatsEntry 7 } llcPortStatsUnknownSaps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that a connection attempt, from a remote LLC station, for an unknown SAP was detected on this port." ::= { llcPortStatsEntry 8 } --;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; -- -- THE LLC SAP GROUP -- ================= -- -- The following classes of information are modeled for each local SAP: -- -- 1. ADMINISTRATIVE ( read-write) -- 2. OPERATIONAL ( read-only) -- 3. STATISTICS ( read-only) -- ************************************************************* -- * * -- * THE LLC SAP ADMINISTRATIVE TABLE * -- * * -- ************************************************************* llcSapAdminTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcSapAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects that can be changed to manage a local SAP. Changing one of these parameters may take effect in the operating CC immediately or may wait until the interface is restarted depending on the details of the implementation." ::= { llcSapGroup 1 } llcSapAdminEntry OBJECT-TYPE SYNTAX LlcSapAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of configured values for a local SAP." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber } ::= { llcSapAdminTable 1 } LlcSapAdminEntry ::= SEQUENCE { llcSapNumber INTEGER, llcSapAdminMaxPDUOctets Integer32, llcSapAdminMaxUnackedIPDUsSend INTEGER, llcSapAdminMaxUnackedIPDUsRcv INTEGER, llcSapAdminMaxRetransmits Integer32, llcSapAdminAckTimer TimeTicks, llcSapAdminPbitTimer TimeTicks, llcSapAdminRejTimer TimeTicks, llcSapAdminBusyTimer TimeTicks, llcSapAdminInactTimer TimeTicks, llcSapAdminDelayAckCount Integer32, llcSapAdminDelayAckTimer TimeTicks, llcSapAdminNw Integer32 } llcSapNumber OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The address of this local SAP." ::= { llcSapAdminEntry 1 } llcSapAdminMaxPDUOctets OBJECT-TYPE SYNTAX Integer32 UNITS "octets" MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP may send to their remote connection component partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header." DEFVAL { 0 } ::= { llcSapAdminEntry 2 } llcSapAdminMaxUnackedIPDUsSend OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this SAP may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component." DEFVAL { 0 } ::= { llcSapAdminEntry 3 } llcSapAdminMaxUnackedIPDUsRcv OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame." DEFVAL { 0 } ::= { llcSapAdminEntry 4 } llcSapAdminMaxRetransmits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the maximum number of times that LLCs on this SAP shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxRetransmits, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxRetransmits." DEFVAL { 0 } ::= { llcSapAdminEntry 5 } llcSapAdminAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminAckTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminAckTimer." DEFVAL { 0 } ::= { llcSapAdminEntry 6 } llcSapAdminPbitTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminPbitTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminPbitTimer." DEFVAL { 0 } ::= { llcSapAdminEntry 7 } llcSapAdminRejTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminRejTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminRejTimer." DEFVAL { 0 } ::= { llcSapAdminEntry 8 } llcSapAdminBusyTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. A zero value for this object indicates that the port default, llcPortAdminBusyTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminBusyTimer." DEFVAL { 0 } ::= { llcSapAdminEntry 9 } llcSapAdminInactTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. A zero value for this object indicates that the port default, llcPortAdminInactTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminInactTimer. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used." DEFVAL { 0 } ::= { llcSapAdminEntry 10 } llcSapAdminDelayAckCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this SAP shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A zero value for this object indicates that the port default, llcPortAdminDelayAck, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminDelayAckCount. A value of one indicates that acknowledgments will be sent immediately and that the value of llcSapAdminDelayAckTimer shall be ignored." DEFVAL { 0 } ::= { llcSapAdminEntry 11 } llcSapAdminDelayAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the time interval during which the LLCs on this SAP shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Receiver Acknowledgment Timer (T2)" DEFVAL { 0 } ::= { llcSapAdminEntry 12 } llcSapAdminNw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This SAP default value may be overridden by a non-zero Cc default value in the llcCcAdminNw object." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Number of Acknowledgments Needed to Increment Ww (Nw)" ::= { llcSapAdminEntry 13 } -- ************************************************************* -- * * -- * THE LLC SAP OPERATIONAL TABLE * -- * * -- ************************************************************* llcSapOperTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcSapOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects that reflect the current operational parameters of a local SAP." ::= { llcSapGroup 2 } llcSapOperEntry OBJECT-TYPE SYNTAX LlcSapOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of configured values for a local SAP." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber } ::= { llcSapOperTable 1 } LlcSapOperEntry ::= SEQUENCE { llcSapOperStatus INTEGER, llcSapOperNumCcs Integer32, llcSapOperHiWaterNumCcs Gauge32, llcSapOperLlc2Support INTEGER } llcSapOperStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes the actual state of this local SAP." ::= { llcSapOperEntry 1 } llcSapOperNumCcs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the number of connection components on this SAP that are currently in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)'." ::= { llcSapOperEntry 2 } llcSapOperHiWaterNumCcs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the highest number of connection components on this SAP simultaneously in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)' concurrently on this SAP." ::= { llcSapOperEntry 3 } llcSapOperLlc2Support OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes whether or not the LLC implementation supports LLC2 connection components." ::= { llcSapOperEntry 4 } -- ************************************************************* -- * * -- * THE LLC SAP STATISTICS TABLE * -- * * -- ************************************************************* llcSapStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcSapStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects that reflect the current operational parameters of a local SAP." ::= { llcSapGroup 3 } llcSapStatsEntry OBJECT-TYPE SYNTAX LlcSapStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of configured values for a local SAP." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber } ::= { llcSapStatsTable 1 } LlcSapStatsEntry ::= SEQUENCE { llcSapStatsLocalBusies Counter32, llcSapStatsRemoteBusies Counter32, llcSapStatsIFramesIn Counter32, llcSapStatsIFramesOut Counter32, llcSapStatsIOctetsIn Counter32, llcSapStatsIOctetsOut Counter32, llcSapStatsSFramesIn Counter32, llcSapStatsSFramesOut Counter32, llcSapStatsRetransmitsOut Counter32, llcSapStatsREJsIn Counter32, llcSapStatsREJsOut Counter32, llcSapStatsWwCount Counter32, llcSapStatsTESTCommandsIn Counter32, llcSapStatsTESTCommandsOut Counter32, llcSapStatsTESTResponsesIn Counter32, llcSapStatsTESTResponsesOut Counter32, llcSapStatsXIDCommandsIn Counter32, llcSapStatsXIDCommandsOut Counter32, llcSapStatsXIDResponsesIn Counter32, llcSapStatsXIDResponsesOut Counter32, llcSapStatsUIFramesIn Counter32, llcSapStatsUIFramesOut Counter32, llcSapStatsUIOctetsIn Counter32, llcSapStatsUIOctetsOut Counter32, llcSapStatsConnectOk Counter32, llcSapStatsConnectFail Counter32, llcSapStatsDisconnect Counter32, llcSapStatsDisconnectFRMRSend Counter32, llcSapStatsDisconnectFRMRRcv Counter32, llcSapStatsDisconnectTimer Counter32, llcSapStatsDMsInABM Counter32, llcSapStatsSABMEsInABM Counter32 } llcSapStatsLocalBusies OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that the local connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 1 } llcSapStatsRemoteBusies OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that the adjacent (i.e. remote) connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 2 } llcSapStatsIFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 3 } llcSapStatsIFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 4 } llcSapStatsIOctetsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 5 } llcSapStatsIOctetsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 6 } llcSapStatsSFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of S-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer." ::= { llcSapStatsEntry 7 } llcSapStatsSFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of S-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer." ::= { llcSapStatsEntry 8 } llcSapStatsRetransmitsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames retransmitted by all local connection components on this SAP. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 9 } llcSapStatsREJsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total REJ frames received from all adjacent LLC connection components on this SAP since it was created." ::= { llcSapStatsEntry 10 } llcSapStatsREJsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total REJ frames transmitted to an adjacent LLC connection components on this SAP since it was created." ::= { llcSapStatsEntry 11 } llcSapStatsWwCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times, since this SAP was created, that the dynamic window algorithm has been invoked to reduce the value of Ww on any of the connection components of this SAP. This object is initialized to zero when the SAP is created. This function is not described in the IEEE 802.2 specification [5], but is widely implemented." ::= { llcSapStatsEntry 12 } llcSapStatsTESTCommandsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of TEST commands this SAP has received and is a measure of the number of stations in the network trying to connect up. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 13 } llcSapStatsTESTCommandsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of TEST commands this SAP has sent and is a measure of the number of other stations we are trying to connect to. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 14 } llcSapStatsTESTResponsesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of TEST responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 15 } llcSapStatsTESTResponsesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of TEST responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 16 } llcSapStatsXIDCommandsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of XID commands this SAP has received and is a measure of the number of stations in the network trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 17 } llcSapStatsXIDCommandsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of XID commands this SAP has sent and is a measure of the number of other stations this SAP is trying to connect to. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 18 } llcSapStatsXIDResponsesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of XID responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 19 } llcSapStatsXIDResponsesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the number of XID responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 20 } llcSapStatsUIFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of unnumbered information (UI) frames received on a local SAP." ::= { llcSapStatsEntry 21 } llcSapStatsUIFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of unnumbered information (UI) frames sent on a local SAP." ::= { llcSapStatsEntry 22 } llcSapStatsUIOctetsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 23 } llcSapStatsUIOctetsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created." ::= { llcSapStatsEntry 24 } llcSapStatsConnectOk OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of successful connections that have been established on this SAP since the SAP was created. A successful connection is indicated by a successful SABME/UA exchange." ::= { llcSapStatsEntry 25 } llcSapStatsConnectFail OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of unsuccessful connections that have been attempted on this SAP since the SAP was created. An unsuccessful connection attempt is indicated by a SABME/DM exchange or a SABME/timeout." ::= { llcSapStatsEntry 26 } llcSapStatsDisconnect OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of normal disconnections that have been performed on this SAP since the SAP was created. A normal disconnection is indicated by a successful DISC/UA exchange or merely a DISC sent or received." ::= { llcSapStatsEntry 27 } llcSapStatsDisconnectFRMRSend OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of abnormal disconnections (resulting from a FRMR being sent) that have been performed on this SAP since the SAP was created." ::= { llcSapStatsEntry 28 } llcSapStatsDisconnectFRMRRcv OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of abnormal disconnections (resulting from a FRMR being received) that have been performed on this SAP since the SAP was created." ::= { llcSapStatsEntry 29 } llcSapStatsDisconnectTimer OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of abnormal disconnections (resulting from a timer expiration) that have been performed on this SAP since the SAP was created." ::= { llcSapStatsEntry 30 } llcSapStatsDMsInABM OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of Disconnect Mode responses that have been received for CCs in ABM mode on this SAP since the SAP was created." ::= { llcSapStatsEntry 31 } llcSapStatsSABMEsInABM OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of SABMEs that have been received for CCs in already in ABM mode on this SAP since the SAP was created." ::= { llcSapStatsEntry 32 } -- -- THE LLC CONNECTION COMPONENT GROUP -- ================================== -- -- The following classes of information are modeled for each LLC connection -- component: -- -- 1. ADMINISTRATIVE ( read-write) -- 2. OPERATIONAL ( read-only) -- 3. STATISTICS ( read-only) -- ************************************************************* -- * * -- * THE LLC CONNECTION COMPONENT ADMINISTRATIVE TABLE * -- * * -- ************************************************************* llcCcAdminTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcCcAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects that can be changed to manage an LLC connection component. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in llcCcAdminTable can be created either by an agent or a management station. The management station can create an entry in llcCcAdminTable by setting the appropriate value in llcCcAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the llcCcOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started." ::= { llcCcGroup 1 } llcCcAdminEntry OBJECT-TYPE SYNTAX LlcCcAdminEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of configured values for an LLC connection component." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber, llcCcRMac, llcCcRSap } ::= { llcCcAdminTable 1 } LlcCcAdminEntry ::= SEQUENCE { llcCcRMac MacAddress, llcCcRSap INTEGER, llcCcAdminBounce INTEGER, llcCcAdminMaxPDUOctets Integer32, llcCcAdminMaxUnackedIPDUsSend INTEGER, llcCcAdminMaxUnackedIPDUsRcv INTEGER, llcCcAdminMaxRetransmits Integer32, llcCcAdminAckTimer TimeTicks, llcCcAdminPbitTimer TimeTicks, llcCcAdminRejTimer TimeTicks, llcCcAdminBusyTimer TimeTicks, llcCcAdminInactTimer TimeTicks, llcCcAdminDelayAckCount Integer32, llcCcAdminDelayAckTimer TimeTicks, llcCcAdminNw Integer32, llcCcAdminRowStatus RowStatus } llcCcRMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value is the remote MAC address for this Connection Component. This value is provided by the SNMP agent." ::= { llcCcAdminEntry 1 } llcCcRSap OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This value is the address of the remote SAP for this Connection Component. This value is provided by the SNMP agent." ::= { llcCcAdminEntry 2 } llcCcAdminBounce OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object controls the resetting of the connection component. Setting this value to yes(2) results in the connection component being reset, llcCcOperState transitioning to a value of aDm(1), and the value of llcCcAdminBounce being set back to no(1)." DEFVAL { no } ::= { llcCcAdminEntry 3 } llcCcAdminMaxPDUOctets OBJECT-TYPE SYNTAX Integer32 UNITS "octets" MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header." DEFVAL { 0 } ::= { llcCcAdminEntry 4 } llcCcAdminMaxUnackedIPDUsSend OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component." DEFVAL { 0 } ::= { llcCcAdminEntry 5 } llcCcAdminMaxUnackedIPDUsRcv OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame." DEFVAL { 0 } ::= { llcCcAdminEntry 6 } llcCcAdminMaxRetransmits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxRetransmits, shall be used." DEFVAL { 0 } ::= { llcCcAdminEntry 7 } llcCcAdminAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminAckTimer, shall be used." DEFVAL { 0 } ::= { llcCcAdminEntry 8 } llcCcAdminPbitTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminPbitTimer, shall be used." DEFVAL { 0 } ::= { llcCcAdminEntry 9 } llcCcAdminRejTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminRejTimer, shall be used." DEFVAL { 0 } ::= { llcCcAdminEntry 10 } llcCcAdminBusyTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminBusyTimer, shall be used." DEFVAL { 0 } ::= { llcCcAdminEntry 11 } llcCcAdminInactTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminInactTimer, shall be used. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used." DEFVAL { 0 } ::= { llcCcAdminEntry 12 } llcCcAdminDelayAckCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminDelayAck, shall be used. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcAdminDelayAckTimer shall be ignored." DEFVAL { 0 } ::= { llcCcAdminEntry 13 } llcCcAdminDelayAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object contains an administrative value which will be applied the next time this connection is established. This object is associated with the llcCcAdminDelayAckCount object and is only defined if that object has a value greater than one." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Receiver Acknowledgment Timer (T2)" DEFVAL { 0 } ::= { llcCcAdminEntry 14 } llcCcAdminNw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Number of Acknowledgments Needed to Increment Ww (Nw)" ::= { llcCcAdminEntry 15 } llcCcAdminRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used by a management station to create or delete the row entry in llcCcAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the llcCcOperTable with llcCcOperState equal to 'aDM (1)'." ::= { llcCcAdminEntry 16 } -- ************************************************************* -- * * -- * THE LLC CONNECTION COMPONENT OPERATIONAL TABLE * -- * * -- ************************************************************* llcCcOperTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcCcOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains current LLC link parameters. Many of these objects have corresponding objects in the llcCcAdminTable." ::= { llcCcGroup 2 } llcCcOperEntry OBJECT-TYPE SYNTAX LlcCcOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of status and control values for an LLC connection component." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber, llcCcRMac, llcCcRSap } ::= { llcCcOperTable 1 } LlcCcOperEntry ::= SEQUENCE { llcCcOperState INTEGER, llcCcOperMaxIPDUOctetsSend Integer32, llcCcOperMaxIPDUOctetsRcv Integer32, llcCcOperMaxUnackedIPDUsSend INTEGER, llcCcOperMaxUnackedIPDUsRcv INTEGER, llcCcOperMaxRetransmits Integer32, llcCcOperAckTimer TimeTicks, llcCcOperPbitTimer TimeTicks, llcCcOperRejTimer TimeTicks, llcCcOperBusyTimer TimeTicks, llcCcOperInactTimer TimeTicks, llcCcOperDelayAckCount Integer32, llcCcOperDelayAckTimer TimeTicks, llcCcOperNw Integer32, llcCcOperWw INTEGER, llcCcOperCreateTime TimeStamp, llcCcOperLastModifyTime TimeStamp, llcCcOperLastFailTime TimeStamp, llcCcOperLastFailCause INTEGER, llcCcOperLastFailFRMRInfo OCTET STRING, llcCcOperLastWwCause INTEGER } llcCcOperState OBJECT-TYPE SYNTAX INTEGER { aDM(1), setup(2), normal(3), busy(4), reject(5), await(6), awaitBusy(7), awaitReject(8), dConn(9), reset(10), error(11), conn(12), resetCheck(13), resetWait(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the operational state of the LLC connection. If the connection component is disabled, llcCcOperState will transition to aDM(1). If the connection component is enabled, llcCcOperState will transition to normal(3)." REFERENCE "ISO 8802-2 : 1989, ANSI/IEEE 802.2 - 1989 Section 7.9.2.1. Connection Component State Descriptions" ::= { llcCcOperEntry 1 } llcCcOperMaxIPDUOctetsSend OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect that in this object. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header." ::= { llcCcOperEntry 2 } llcCcOperMaxIPDUOctetsRcv OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the maximum I PDU size, in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5] The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header." ::= { llcCcOperEntry 3 } llcCcOperMaxUnackedIPDUsSend OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect that in this object." ::= { llcCcOperEntry 4 } llcCcOperMaxUnackedIPDUsRcv OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]." ::= { llcCcOperEntry 5 } llcCcOperMaxRetransmits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]." ::= { llcCcOperEntry 6 } llcCcOperAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times)." ::= { llcCcOperEntry 7 } llcCcOperPbitTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times)." ::= { llcCcOperEntry 8 } llcCcOperRejTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times)." ::= { llcCcOperEntry 9 } llcCcOperBusyTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive." ::= { llcCcOperEntry 10 } llcCcOperInactTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used." ::= { llcCcOperEntry 11 } llcCcOperDelayAckCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcOperDelayAckTimer should be ignored." ::= { llcCcOperEntry 12 } llcCcOperDelayAckTimer OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcCcOperDelayAckCount object and only has meaning if that object has a value greater than one." ::= { llcCcOperEntry 13 } llcCcOperNw OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5], but is widely implemented." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations Number of Acknowledgments Needed to Increment Ww (Nw)" ::= { llcCcOperEntry 14 } llcCcOperWw OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of sequentially numbered IPDUs that the connection component may have outstanding (unacknowledged) at any given time. Ww is initialized to the value of llcCcOperMaxUnackedIPDUsSend when the link is established. When the dynamic window algorithm is invoked, Ww varies from 1 up to llcCcOperMaxUnackedIPDUsSend. Each time the llcCcOperWw value is decreased, the reason is recorded in llcCcOperLastWwCause, and llcCcStatWwCount is incremented by 1. This function is not described in the IEEE 802.2 specification [5], but is widely implemented." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 8: LLC Frames Working Window Size, Ww" ::= { llcCcOperEntry 15 } llcCcOperCreateTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the value of sysUpTime when this connection was created." ::= { llcCcOperEntry 16 } llcCcOperLastModifyTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the value of sysUpTime the last time this connection component was modified. If the connection has not been modified, then this value shall be zero." ::= { llcCcOperEntry 17 } llcCcOperLastFailTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes the value of sysUpTime when this LLC connection component last failed. If the connection component has not failed, then this value shall be zero." ::= { llcCcOperEntry 18 } llcCcOperLastFailCause OBJECT-TYPE SYNTAX INTEGER { undefined(1), rxFRMR(2), txFRMR(3), discReceived(4), discSent(5), retriesExpired(6), forcedShutdown(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This enumerated object reflects the cause of the last failure of this LLC connection component. If the connection component has not failed, then this object will have a value of undefined(1)." DEFVAL { undefined } ::= { llcCcOperEntry 19 } llcCcOperLastFailFRMRInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the information field of the FRMR frame if the last failure for this LLC connection component was as a result of an invalid frame. Otherwise, this field has no meaning." ::= { llcCcOperEntry 20 } llcCcOperLastWwCause OBJECT-TYPE SYNTAX INTEGER { neverInvoked(1), lostData(2), macLayerCongestion(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the reason that the llcCcOperWw was reduced the last time this occurred." REFERENCE "IBM Token-Ring Network Architecture Ref. SC30-3374 Chapter 11: Operation of Link Stations The Dynamic Window Algorithm." ::= { llcCcOperEntry 21 } -- ************************************************************* -- * * -- * THE LLC CONNECTION COMPONENT STATISTICS TABLE * -- * * -- ************************************************************* llcCcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF LlcCcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table contains statistics for a specific LLC connection component." ::= { llcCcGroup 3 } llcCcStatsEntry OBJECT-TYPE SYNTAX LlcCcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of statistics for an LLC connection component." INDEX { ifIndex, llcPortVirtualIndex, llcSapNumber, llcCcRMac, llcCcRSap } ::= { llcCcStatsTable 1 } LlcCcStatsEntry ::= SEQUENCE { llcCcStatsLocalBusies Counter32, llcCcStatsRemoteBusies Counter32, llcCcStatsIFramesIn Counter32, llcCcStatsIFramesOut Counter32, llcCcStatsIOctetsIn Counter32, llcCcStatsIOctetsOut Counter32, llcCcStatsSFramesIn Counter32, llcCcStatsSFramesOut Counter32, llcCcStatsRetransmitsOut Counter32, llcCcStatsREJsIn Counter32, llcCcStatsREJsOut Counter32, llcCcStatsWwCount Counter32 } llcCcStatsLocalBusies OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that the local connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 1 } llcCcStatsRemoteBusies OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times that the adjacent (i.e. remote) connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 2 } llcCcStatsIFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames that have been received by the connection component. This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 3 } llcCcStatsIFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 4 } llcCcStatsIOctetsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets received from the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 5 } llcCcStatsIOctetsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total octets transmitted to the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 6 } llcCcStatsSFramesIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of S-Frames that have been received by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer." ::= { llcCcStatsEntry 7 } llcCcStatsSFramesOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of S-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer." ::= { llcCcStatsEntry 8 } llcCcStatsRetransmitsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of I-Frames retransmitted the local connection component. This object is initialized to zero when the connection component is created." ::= { llcCcStatsEntry 9 } llcCcStatsREJsIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total REJ frames received from an adjacent LLC connection component since connection component startup." ::= { llcCcStatsEntry 10 } llcCcStatsREJsOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total REJ frames transmitted to an adjacent LLC connection component since connection component startup." ::= { llcCcStatsEntry 11 } llcCcStatsWwCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object reflects the total number of times, since connection component startup, that the dynamic window algorithm has been invoked to reduce the value of Ww. At connection component startupm this object must be initialized to zero. This function is not described in the IEEE 802.2 specification [5], but is widely implemented." ::= { llcCcStatsEntry 12 } -- ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; -- -- Notifications -- snaLlcMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoSnaLlcMIB 2 } snaLlcMIBNotifications OBJECT IDENTIFIER ::= { snaLlcMIBNotificationPrefix 0 } llcCcStatusChange NOTIFICATION-TYPE OBJECTS { llcCcOperState, llcCcOperLastFailTime, llcCcOperLastFailCause, llcCcOperLastFailFRMRInfo } STATUS current DESCRIPTION "This trap indicates that the state of an LLC connection component has transitioned to normal(3) or aDM(1)." ::= { snaLlcMIBNotifications 1 } -- ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; -- -- Conformance Information -- snaLlcMIBConformance OBJECT IDENTIFIER ::= { ciscoSnaLlcMIB 3 } snaLlcMIBCompliances OBJECT IDENTIFIER ::= { snaLlcMIBConformance 1 } snaLlcMIBGroups OBJECT IDENTIFIER ::= { snaLlcMIBConformance 2 } -- -- Compliance Statements -- llcCoreCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The core compliance statement for all LLC nodes." MODULE MANDATORY-GROUPS { llcCorePortGroup, llcCoreSapGroup, llcCoreCcGroup } OBJECT llcPortAdminName MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminMaxSaps MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminMaxCcs MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminMaxPDUOctets MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminMaxUnackedIPDUsSend MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminMaxRetransmits MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminAckTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminPbitTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminRejTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminBusyTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminInactTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminDelayAckCount MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminDelayAckTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcPortAdminNw MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminMaxPDUOctets MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminMaxUnackedIPDUsSend MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminMaxRetransmits MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminAckTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminPbitTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminRejTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminBusyTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminInactTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminDelayAckCount MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminDelayAckTimer MIN-ACCESS read-only DESCRIPTION "Write access not required" OBJECT llcSapAdminNw MIN-ACCESS read-only DESCRIPTION "Write access not required" ::= { snaLlcMIBCompliances 1 } -- -- Core Conformance Groups for All Connection Components -- llcCorePortGroup OBJECT-GROUP OBJECTS { llcPortAdminName, llcPortAdminMaxSaps, llcPortAdminMaxCcs, llcPortAdminMaxPDUOctets, llcPortAdminMaxUnackedIPDUsSend, llcPortAdminMaxUnackedIPDUsRcv, llcPortAdminMaxRetransmits, llcPortAdminAckTimer, llcPortAdminPbitTimer, llcPortAdminRejTimer, llcPortAdminBusyTimer, llcPortAdminInactTimer, llcPortAdminDelayAckCount, llcPortAdminDelayAckTimer, llcPortAdminNw, llcPortOperMacAddress, llcPortOperNumSaps, llcPortOperHiWaterNumSaps, llcPortOperSimRim, llcPortOperLastModifyTime, llcPortStatsPDUsIn, llcPortStatsPDUsOut, llcPortStatsOctetsIn, llcPortStatsOctetsOut, llcPortStatsTESTCommandsIn, llcPortStatsTESTResponsesOut, llcPortStatsLocalBusies, llcPortStatsUnknownSaps } STATUS current DESCRIPTION "The llcCorePortGroup defines objects which are common to the LLC Port of all compliant connections." ::= { snaLlcMIBGroups 1 } llcCoreSapGroup OBJECT-GROUP OBJECTS { llcSapAdminMaxPDUOctets, llcSapAdminMaxUnackedIPDUsSend, llcSapAdminMaxUnackedIPDUsRcv, llcSapAdminMaxRetransmits, llcSapAdminAckTimer, llcSapAdminPbitTimer, llcSapAdminRejTimer, llcSapAdminBusyTimer, llcSapAdminInactTimer, llcSapAdminDelayAckCount, llcSapAdminDelayAckTimer, llcSapAdminNw, llcSapOperStatus, llcSapOperNumCcs, llcSapOperHiWaterNumCcs, llcSapOperLlc2Support, llcSapStatsLocalBusies, llcSapStatsRemoteBusies, llcSapStatsIFramesIn, llcSapStatsIFramesOut, llcSapStatsIOctetsIn, llcSapStatsIOctetsOut, llcSapStatsSFramesIn, llcSapStatsSFramesOut, llcSapStatsRetransmitsOut, llcSapStatsREJsIn, llcSapStatsREJsOut, llcSapStatsWwCount, llcSapStatsTESTCommandsIn, llcSapStatsTESTCommandsOut, llcSapStatsTESTResponsesIn, llcSapStatsTESTResponsesOut, llcSapStatsXIDCommandsIn, llcSapStatsXIDCommandsOut, llcSapStatsXIDResponsesIn, llcSapStatsXIDResponsesOut, llcSapStatsUIFramesIn, llcSapStatsUIFramesOut, llcSapStatsUIOctetsIn, llcSapStatsUIOctetsOut, llcSapStatsConnectOk, llcSapStatsConnectFail, llcSapStatsDisconnect, llcSapStatsDisconnectFRMRSend, llcSapStatsDisconnectFRMRRcv, llcSapStatsDisconnectTimer, llcSapStatsDMsInABM, llcSapStatsSABMEsInABM } STATUS current DESCRIPTION "The llcCoreSapGroup defines objects which are common to the LLC SAP of all compliant connections." ::= { snaLlcMIBGroups 2 } llcCoreCcGroup OBJECT-GROUP OBJECTS { llcCcAdminBounce, llcCcAdminMaxPDUOctets, llcCcAdminMaxUnackedIPDUsSend, llcCcAdminMaxUnackedIPDUsRcv, llcCcAdminMaxRetransmits, llcCcAdminAckTimer, llcCcAdminPbitTimer, llcCcAdminRejTimer, llcCcAdminBusyTimer, llcCcAdminInactTimer, llcCcAdminDelayAckCount, llcCcAdminDelayAckTimer, llcCcAdminNw, llcCcAdminRowStatus, llcCcOperState, llcCcOperMaxIPDUOctetsSend, llcCcOperMaxIPDUOctetsRcv, llcCcOperMaxUnackedIPDUsSend, llcCcOperMaxUnackedIPDUsRcv, llcCcOperMaxRetransmits, llcCcOperAckTimer, llcCcOperPbitTimer, llcCcOperRejTimer, llcCcOperBusyTimer, llcCcOperInactTimer, llcCcOperDelayAckCount, llcCcOperDelayAckTimer, llcCcOperNw, llcCcOperWw, llcCcOperCreateTime, llcCcOperLastModifyTime, llcCcOperLastFailTime, llcCcOperLastFailCause, llcCcOperLastFailFRMRInfo, llcCcOperLastWwCause, llcCcStatsLocalBusies, llcCcStatsRemoteBusies, llcCcStatsIFramesIn, llcCcStatsIFramesOut, llcCcStatsIOctetsIn, llcCcStatsIOctetsOut, llcCcStatsSFramesIn, llcCcStatsSFramesOut, llcCcStatsRetransmitsOut, llcCcStatsREJsIn, llcCcStatsREJsOut, llcCcStatsWwCount } STATUS current DESCRIPTION "The llcCoreCcGroup defines objects which are common to the LLC CC of all compliant connections." ::= { snaLlcMIBGroups 3 } END