CISCO-WAN-MODULE-MIB device MIB details by Cisco
CISCO-WAN-MODULE-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-WAN-MODULE-MIB.
Vendor: | Cisco |
---|---|
Mib: | CISCO-WAN-MODULE-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- ***************************************************************** -- ciscoWanModule MIB -- -- The MIB supported in WAN Module -- -- May 1999, Shilpa Kale -- July 2001, Rajesh Kumar -- Sept 2002, Subra Hegde -- -- Copyright (c) 1999, 2001, 2002 by Cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-WAN-MODULE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC ciscoMgmt FROM CISCO-SMI; ciscoWanModuleMIB MODULE-IDENTITY LAST-UPDATED "200209110000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB to configure Connection Specific parameters and statistics related information in a Service Module. The Service Module(SM) is defined as any Module which provides services such as ATM, Frame Relay or Voice in a Wide Area Network(WAN) switch." REVISION "200209110000Z" DESCRIPTION "Imported Unsigned32 from SNMPv2-SMI instead of CISCO-TC. Added cwmUploadCounter in cwmConfigTable." REVISION "200107200000Z" DESCRIPTION " 1. Added cwmSCTFileVerCfg and cwmSCTFileVerOpr to CwmConfigEntry. " REVISION "9910220000Z" DESCRIPTION "Initial version of the mib module." ::= { ciscoMgmt 145 } cwmMIBObjects OBJECT IDENTIFIER ::= { ciscoWanModuleMIB 1} cwmConfig OBJECT IDENTIFIER ::= { cwmMIBObjects 1} cwmStatsConfig OBJECT IDENTIFIER ::= { cwmMIBObjects 2 } StatisticsLevel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Used to configure level statistics on service module. Statistic level on a module dictates the type and amount of statistics that is collected. There is a predefined set of statistics associated with each level and are enabled when a level is set. Also, setting statistics level to N will enable counters associated with levels N-1 through 1 as well. The valid values are notApplicable(0)- Statistics level is not applicable. levelOne(1) - Enables level one counters. levelTwo(2) - Enables level two and level one counters. levelThree(3) - Enables level one, level two and level three counters." SYNTAX INTEGER{ notApplicable(0), levelOne(1), levelTwo(2), levelThree(3) } -- Module configuration Table cwmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CwmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects required for configuring module specific parameters. These parameters may be related to the hardware specific parameters which can affect the ATM Connection characteristics." ::= { cwmConfig 1} cwmConfigEntry OBJECT-TYPE SYNTAX CwmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information for each module." INDEX { cwmIndex } ::= { cwmConfigTable 1 } CwmConfigEntry ::= SEQUENCE { cwmIndex Unsigned32, cwmIngressSCTFileId Unsigned32, cwmIngressSCTFileName DisplayString, cwmAutoLineDiagEnable INTEGER, cwmSCTFileVerCfg Unsigned32, cwmSCTFileVerOpr Unsigned32, cwmUploadCounter Unsigned32 } cwmIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object's value generally corresponds to the slot number where the module resides. However, system wide uniqueness is the only true requirement." ::= {cwmConfigEntry 1 } cwmIngressSCTFileId OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The file ID of the Service Class Template(SCT) file. The SCT holds the connection specific parameters for this module in the ingress direction(From Network to the Switch). Terminologies used: SCT : Service Class Template The Service Class Template ( or Service Template or SCT ) provides a means for inferring extended parameters, which are generally platform-specific, from the set of standard ATM protocol parameters passed in VSI(Virtual Switch Interface) connection setup primitives. A set of Service Templates are available in a non-volatile storage and is downloaded onto each Service Module on power up. In general, SCTs contain two classes of data. One class consists of parameters necessary to establish a Virtual Connection (i.e. Per-VC) and includes entries such as UPC(Usage Parameter Control) actions, various bandwidth-related items, per-VC thresholds, and some hardware-specific items.The second class of data items includes those necessary to configure the associated Class-of-Service Buffers that provide the QoS support." ::= {cwmConfigEntry 2 } cwmIngressSCTFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the SCT filename. Write access is not required. The filename has cwmIngressSCTFileId value as the suffix. For example, the value SCT.INGR.13 for this object indicates 13 is the value of cwmIngressSCTFileId." ::= { cwmConfigEntry 3 } cwmAutoLineDiagEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables automatic diagnostic feature of physical lines on module. In case of a line alarm, enabling this feature temporarily suspends traffic in both direction and starts local loop-back testing. Disabling this feature will not effect the traffic in one direction while another direction is in alarm." DEFVAL { disable } ::= { cwmConfigEntry 4 } cwmSCTFileVerCfg OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Configured version of the Service Class Template(SCT) file. This version applies to both the card SCT and the port SCT files in a service module. The port SCT files are specified while provisioning a port using the caviFileId field in the CISCO-WAN-VIRTUAL-IF-MIB.my MIB. The card SCT file is specifed in this MIB using the cwmIngressSCTFileName object. The configured version of the SCT does not take effect until the service module is rebooted. However, graceful invocation of a new SCT version can be achieved by using redundant service modules. The configured SCT version is first applied on a standby service module by rebooting it. When the standby reboots, it comes up with the configured SCT version. Thereafter a switchover can be performed, making the standby SM take over as active." ::= {cwmConfigEntry 5 } cwmSCTFileVerOpr OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The operational version of the Service Class Template(SCT) file. This is sct version currently in use. The operational version could be different from the configured version (cwmSCTFileVerCfg), until the service module is rebooted." ::= {cwmConfigEntry 6 } cwmUploadCounter OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is used by the management station to determine if any changes(other than ATM/FR connections) have been done on configuration of a card. The use of this object is implementation specific. This requires the NMS application saving the previous value of this object and compare it later for finding any changes in the card. The upload counter is incremented in, for instance: - any physical interface characteristics are modified. - any logical interface is added/deleted/modified. - any IMA Group/MFR bundle is added/deleted/modified. - any resource is added/deleted/modified on an interface. - any configuration changes are done(not specified above) which are not related to ATM/FR Connections (SPVCs for example)." ::= {cwmConfigEntry 7 } -- Statistics Configuration Table cwmStatConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CwmStatConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table has objects required for configuring module statistic collection related parameters. The statistics related to interfaces and ATM Connections are stored in a file. The statistics file can be uploaded by NMS applications using file transfer protocols such as tftp or ftp. While current interval of data is being collected in memory, previous interval of data is uploaded by NMS. Each interval's data will overwrite the previous interval's data in the statistic file after the interval is over." ::= { cwmStatsConfig 1 } cwmStatConfigEntry OBJECT-TYPE SYNTAX CwmStatConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing statistics configuration information for the module." INDEX { cwmIndex } ::= { cwmStatConfigTable 1 } CwmStatConfigEntry ::= SEQUENCE { cwmStatBucketInterval INTEGER, cwmStatCollectionInterval INTEGER, cwmStatCollectionStatus INTEGER, cwmStatCurrentLevel StatisticsLevel, cwmStatLevelConfigured StatisticsLevel, cwmStatMaximumConnections Unsigned32 } cwmStatBucketInterval OBJECT-TYPE SYNTAX INTEGER { five(5), ten(10), fifteen(15), twenty(20), thirty(30), sixty(60) } UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the bucket interval in minutes used in collecting statistics. This specifies the interval over which the module accumulates a sample. This value also defines the amount of time available to NMS application to upload the statistic file in order to not miss one interval worth of data." DEFVAL { fifteen } ::= {cwmStatConfigEntry 1 } cwmStatCollectionInterval OBJECT-TYPE SYNTAX INTEGER { default(0), one(1), five(5) } UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "The collection interval of statistics. Within a sampling interval, as defined by cwmStatBucketInterval, statistics counters are updated every collection interval. Default value of collection interval is same as bucket interval. In case of bucket interval being 5 minutes, default(0) and five(5) values for this object has the same effect." DEFVAL { default } ::= {cwmStatConfigEntry 2 } cwmStatCollectionStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables statistics collection on the module." DEFVAL { enable } ::= {cwmStatConfigEntry 3 } cwmStatCurrentLevel OBJECT-TYPE SYNTAX StatisticsLevel MAX-ACCESS read-only STATUS current DESCRIPTION "The current statistics level of the module. A change in the card statistic level can take place only after a module reset. This object shows the current module statistic level. While cwmStatLevelConfigured object is used to configure module statistic level. The value set in cwmStatLevelConfigured object will take effect after next module reset." ::= {cwmStatConfigEntry 4 } cwmStatLevelConfigured OBJECT-TYPE SYNTAX StatisticsLevel MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to configure the statistics level for the module. The statistics level value set in this object will take effect only on reset of the module. This object can be set only if cwmStatCollectionStatus is set to enable(1). This object cannot be set to notApplicable(0)." DEFVAL { levelOne } ::= {cwmStatConfigEntry 5 } cwmStatMaximumConnections OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of connections for which the statistics are being collected." ::= { cwmStatConfigEntry 6 } -- Notifications ciscoWanModuleMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoWanModuleMIB 2 } ciscoWanModuleMIBNotifications OBJECT IDENTIFIER ::= { ciscoWanModuleMIBNotificationPrefix 0 } -- conformance information ciscoWanModuleMIBConformance OBJECT IDENTIFIER ::= { ciscoWanModuleMIB 3 } ciscoWanModuleMIBCompliances OBJECT IDENTIFIER ::= {ciscoWanModuleMIBConformance 1} ciscoWanModuleMIBGroups OBJECT IDENTIFIER ::= {ciscoWanModuleMIBConformance 2} ciscoWanModuleMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The Compliance statement for cwmConfigGroup group." MODULE -- this module MANDATORY-GROUPS { cwmConfigGroup } OBJECT cwmIngressSCTFileName MIN-ACCESS read-only DESCRIPTION "Write access is not required if the cwmIngressSCTFileId is specified." GROUP cwmStatConfigGroup DESCRIPTION "Implementation of this group is not mandatory for the modules which does not support statistics collection." OBJECT cwmStatCollectionInterval MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute." OBJECT cwmStatCurrentLevel MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This attribute is not required if the cwmStatLevelConfigured object is not supported." OBJECT cwmStatLevelConfigured MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This object is not required if the module does not support the statistics based on statistics level setting." ::= { ciscoWanModuleMIBCompliances 1 } ciscoWanModuleMIBComplianceRev1 MODULE-COMPLIANCE STATUS deprecated -- replaced by -- ciscoWanModuleMIBComplianceRev2 DESCRIPTION "The Compliance statement for cwmConfigGroup group, with addition of SCT file versioning " MODULE -- this module MANDATORY-GROUPS { cwmConfigGroup, cwmConfigGroup2 } OBJECT cwmIngressSCTFileName MIN-ACCESS read-only DESCRIPTION "Write access is not required if the cwmIngressSCTFileId is specified." GROUP cwmStatConfigGroup DESCRIPTION "Implementation of this group is not mandatory for the modules which does not support statistics collection." OBJECT cwmStatCollectionInterval MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute." OBJECT cwmStatCurrentLevel MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This attribute is not required if the cwmStatLevelConfigured object is not supported." OBJECT cwmStatLevelConfigured MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This object is not required if the module does not support the statistics based on statistics level setting." ::= { ciscoWanModuleMIBCompliances 2 } ciscoWanModuleMIBComplianceRev2 MODULE-COMPLIANCE STATUS current DESCRIPTION "The Compliance statement for cwmConfigGroup group, with addition of SCT file versioning " MODULE -- this module MANDATORY-GROUPS { cwmConfigGroup, cwmConfigGroup2 } GROUP cwmUploadGroup DESCRIPTION "The implementation of this group is mandatory where the changes to card configuration can be tracked." OBJECT cwmIngressSCTFileName MIN-ACCESS read-only DESCRIPTION "Write access is not required if the cwmIngressSCTFileId is specified." GROUP cwmStatConfigGroup DESCRIPTION "Implementation of this group is not mandatory for the modules which does not support statistics collection." OBJECT cwmStatCollectionInterval MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute." OBJECT cwmStatCurrentLevel MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This attribute is not required if the cwmStatLevelConfigured object is not supported." OBJECT cwmStatLevelConfigured MIN-ACCESS not-accessible DESCRIPTION "This is an optional attribute. This object is not required if the module does not support the statistics based on statistics level setting." ::= { ciscoWanModuleMIBCompliances 3 } -- units of conformance cwmConfigGroup OBJECT-GROUP OBJECTS { cwmIngressSCTFileId , cwmIngressSCTFileName, cwmAutoLineDiagEnable } STATUS current DESCRIPTION "Group containing Module Specific Parameters." ::= { ciscoWanModuleMIBGroups 1} cwmStatConfigGroup OBJECT-GROUP OBJECTS { cwmStatBucketInterval, cwmStatCurrentLevel, cwmStatLevelConfigured, cwmStatCollectionStatus, cwmStatCollectionInterval, cwmStatMaximumConnections } STATUS current DESCRIPTION "Group containing statistics configuration." ::= { ciscoWanModuleMIBGroups 2} cwmConfigGroup2 OBJECT-GROUP OBJECTS { cwmSCTFileVerCfg, cwmSCTFileVerOpr } STATUS current DESCRIPTION "Group containing additional Module Specific Parameters." ::= { ciscoWanModuleMIBGroups 3} cwmUploadGroup OBJECT-GROUP OBJECTS { cwmUploadCounter } STATUS current DESCRIPTION "Group containing objects related to configuration changes in a card." ::= { ciscoWanModuleMIBGroups 4} END