CPQSINFO-MIB device MIB details by Compaq
CPQSINFO-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CPQSINFO-MIB.
Vendor: | Compaq |
---|---|
Mib: | CPQSINFO-MIB [download] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- **************************************************************************** -- -- Compaq System Information -- Management Information Base for SNMP Network Management -- -- -- Copyright 1997,1998 Compaq Computer Corporation. -- All Rights Reserved. -- -- The information in this document is subject to change without notice. -- -- COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL -- OR EDITORIAL ERRORS OR OMISSIONS CONATINED HEREIN; NOR FOR INCIDENTAL -- OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, -- OR USE OF THIS MATERIAL. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- **************************************************************************** CPQSINFO-MIB DEFINITIONS ::= BEGIN IMPORTS compaq FROM CPQHOST-MIB enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 sysName FROM RFC1213-MIB cpqHoTrapFlags FROM CPQHOST-MIB TRAP-TYPE FROM RFC-1215; -- compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqSystemInfo OBJECT IDENTIFIER ::= { compaq 2 } cpqSiMibRev OBJECT IDENTIFIER ::= { cpqSystemInfo 1 } cpqSiComponent OBJECT IDENTIFIER ::= { cpqSystemInfo 2 } cpqSiInterface OBJECT IDENTIFIER ::= { cpqSiComponent 1 } cpqSiAsset OBJECT IDENTIFIER ::= { cpqSiComponent 2 } cpqSiSecurity OBJECT IDENTIFIER ::= { cpqSiComponent 3 } cpqSiSystemBoard OBJECT IDENTIFIER ::= { cpqSiComponent 4 } cpqSiBoardRev OBJECT IDENTIFIER ::= { cpqSiComponent 5 } cpqSiRackServer OBJECT IDENTIFIER ::= { cpqSiComponent 6 } cpqSiVideo OBJECT IDENTIFIER ::= { cpqSiComponent 7 } cpqSiMonitor OBJECT IDENTIFIER ::= { cpqSiComponent 8 } cpqSiHotPlugSlot OBJECT IDENTIFIER ::= { cpqSiComponent 9 } cpqSiSystemBattery OBJECT IDENTIFIER ::= { cpqSiComponent 10 } cpqSiDockingStation OBJECT IDENTIFIER ::= { cpqSiComponent 11 } cpqSiOsCommon OBJECT IDENTIFIER ::= { cpqSiInterface 4 } -- **************************************************************************** -- Compaq System Information MIB Revision -- ====================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiMibRev Group (1.3.6.1.4.1.232.2.1) -- -- Implementation of the MibRev group is mandatory for all Insight Agents -- supporting the Compaq System Information MIB. -- -- An Insight Agent conforming to this document will return a -- cpqSiMibRevMajor of one (1) and a cpqSiMibRevMinor of fourteen (14). -- -- -- **************************************************************************** cpqSiMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqSiMibRev 1 } cpqSiMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqSiMibRev 2 } cpqSiMibCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), -- default degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition. This object represents the overall status of the Compaq server information represented by this MIB." ::= { cpqSiMibRev 3 } -- **************************************************************************** -- Compaq System Information Common -- ================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1) -- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4) -- -- -- Implementation of the cpqSiOsCommon group is mandatory for all -- Insight Agents that support the System Information MIB. -- -- **************************************************************************** cpqSiOsCommonPollFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance." ::= { cpqSiOsCommon 1 } -- **************************************************************************** -- Compaq System Information Common Module Table -- ============================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1) -- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4) -- cpqSiOsCommonModuleTable (1.3.6.1.4.1.232.2.2.1.4.2) -- -- **************************************************************************** cpqSiOsCommonModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiOsCommonModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of software modules that provide an interface to the device this MIB describes." ::= { cpqSiOsCommon 2 } cpqSiOsCommonModuleEntry OBJECT-TYPE SYNTAX CpqSiOsCommonModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a software module that provides an interface to the device this MIB describes." INDEX { cpqSiOsCommonModuleIndex } ::= { cpqSiOsCommonModuleTable 1 } CpqSiOsCommonModuleEntry ::= SEQUENCE { cpqSiOsCommonModuleIndex INTEGER, cpqSiOsCommonModuleName DisplayString, cpqSiOsCommonModuleVersion DisplayString, cpqSiOsCommonModuleDate OCTET STRING, cpqSiOsCommonModulePurpose DisplayString } cpqSiOsCommonModuleIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for this module description." ::= { cpqSiOsCommonModuleEntry 1 } cpqSiOsCommonModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The module name." ::= { cpqSiOsCommonModuleEntry 2 } cpqSiOsCommonModuleVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) ACCESS read-only STATUS mandatory DESCRIPTION "The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version." ::= { cpqSiOsCommonModuleEntry 3 } cpqSiOsCommonModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first." ::= { cpqSiOsCommonModuleEntry 4 } cpqSiOsCommonModulePurpose OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The purpose of the module described in this entry." ::= { cpqSiOsCommonModuleEntry 5 } -- **************************************************************************** -- Compaq System Information Asset Group -- ===================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiAsset Group (1.3.6.1.4.1.232.2.2.2) -- -- The cpqSiAsset group contains the serial numbers of any Compaq hardware -- that supports asset management. -- -- Implementation of the cpqSiAsset group is mandatory for all Insight -- Agents that support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiSysSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of the system unit. The string will be empty if the system does not report the serial number function." ::= { cpqSiAsset 1 } cpqSiFormFactor OBJECT-TYPE SYNTAX INTEGER { unknown(1), portable(2), laptop(3), desktop(4), tower(5), mini-tower(6), rack-mount(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The form factor of the system. Setting this variable to unknown will fail." ::= { cpqSiAsset 2 } cpqSiAssetTag OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The customer changeable identifier that is set to the system serial number at the time of manufacture. The string will be empty if the system does not report this function." ::= { cpqSiAsset 3 } cpqSiOwnershipTag OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) ACCESS read-only STATUS mandatory DESCRIPTION "This is a customer changeable identifier that will be displayed by ROM at POST. This is an 80 byte standard ASCII character string and is Administrator Password protected. An example could be: Property of Compaq Computer Corporation The string should be NULL terminated. This item will be empty if the system does not report this function." ::= { cpqSiAsset 4 } cpqSiSysServiceNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The service number of the system unit. The string will be empty if the system does not report the system service number." ::= { cpqSiAsset 5 } -- **************************************************************************** -- Compaq System Information Security Group -- ======================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSecurity Group (1.3.6.1.4.1.232.2.2.3) -- -- The Security group describes how the security features on your Compaq -- computer are currently configured. -- -- Implementation of the security group is mandatory for all agents that -- support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiPowerOnPassword OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the power on password feature." ::= { cpqSiSecurity 1 } cpqSiNetServerMode OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the network server mode feature." ::= { cpqSiSecurity 2 } cpqSiQuickLockPassword OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the quicklock password feature." ::= { cpqSiSecurity 3 } cpqSiQuickBlank OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the quick blank screen feature." ::= { cpqSiSecurity 4 } cpqSiDisketteBootControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the diskette boot control feature." ::= { cpqSiSecurity 5 } cpqSiSerialPortAControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the primary serial port interface embedded in the Compaq system board." ::= { cpqSiSecurity 6 } cpqSiSerialPortBControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the secondary serial port interface embedded in the Compaq system board." ::= { cpqSiSecurity 7 } cpqSiParallelPortControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the parallel port interface embedded in the Compaq system board." ::= { cpqSiSecurity 8 } cpqSiFloppyDiskControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the floppy diskette interface embedded in the Compaq system board." ::= { cpqSiSecurity 9 } cpqSiFixedDiskControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the fixed disk interface embedded in the Compaq system board." ::= { cpqSiSecurity 10 } cpqSiHoodRemovedTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Last detection of hood removed by Compaq Smart Hood Sensor." ::= { cpqSiSecurity 11 } cpqSiHoodSensorConfiguration OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), notifyUser(3), adminPasswordProtected(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the current configuration of the Compaq Smart Cover sensor. The following values are currently defined: other(1) Smart Cover sensor is not supported on this system or cannot be determined by the Insight Agent. You may need to upgrade your software. disabled(2) Smart Cover sensor will not detect a hood removal and cpqSiHoodRemovedTime will not be updated. notifyUser(3) Smart Cover sensor will detect a hood removal and will display a message at POST for the user. adminPasswordProtected(4) Smart Cover sensor will detect a hood removal and will display a message at POST for the user to enter the Admin Password. The system will not boot until proper password is entered." ::= { cpqSiSecurity 12 } cpqSiSmartCoverLockStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unlocked(2), locked(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the current status of the Compaq Smart Cover Lock. The following values are currently defined: other(1) Smart Cover Lock is not supported on this system or cannot be determined by the Insight Agent. You may need to upgrade your software. unlocked(2) Smart Cover Lock is not locked. The status will be set to unlocked due to one of the following: 1. The system hood is removed, or 2. There is no administrator password set, or 3. The administrator manually sets status to unlock. locked(3) Smart Cover Lock is locked. The administrator password is required to unlock the hood." ::= { cpqSiSecurity 13 } cpqSiUSBPortControl OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the access control for the Universal Serial Bus interface(s) embedded in the Compaq system board." ::= { cpqSiSecurity 14 } -- **************************************************************************** -- Compaq System Information System Board Group -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4) -- -- The cpqSiSystemBoard group describe features of your Compaq computer -- system board. -- -- Implementation of the cpqSiSystemBoard group is mandatory for all agents -- that support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiProductId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The machine product ID. This value indicates the Compaq product type of the system board in this system. The value 127 will be given if the machine ID cannot be determined." ::= { cpqSiSystemBoard 1 } cpqSiProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The machine product name. The name of the Compaq machine used in this system." ::= { cpqSiSystemBoard 2 } cpqSiAuxiliaryInput OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the auxiliary input (pointing) device." ::= { cpqSiSystemBoard 4 } -- **************************************************************************** -- Compaq System Information Memory Module Table -- ============================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4) -- cpqSiMemModuleTable (1.3.6.1.4.1.232.2.2.4.5) -- cpqSiMemModuleEntry (1.3.6.1.4.1.232.2.2.4.5.1) -- -- **************************************************************************** cpqSiMemModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiMemModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of memory module descriptions." ::= { cpqSiSystemBoard 5 } cpqSiMemModuleEntry OBJECT-TYPE SYNTAX CpqSiMemModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A memory module description." INDEX { cpqSiMemBoardIndex , cpqSiMemModuleIndex } ::= { cpqSiMemModuleTable 1 } CpqSiMemModuleEntry ::= SEQUENCE { cpqSiMemBoardIndex INTEGER, cpqSiMemModuleIndex INTEGER, cpqSiMemModuleSize INTEGER, cpqSiMemModuleType INTEGER, cpqSiMemModuleSpeed INTEGER, cpqSiMemModuleTechnology INTEGER, cpqSiMemModuleManufacturer DisplayString, cpqSiMemModulePartNo DisplayString, cpqSiMemModuleDate OCTET STRING, cpqSiMemModuleSerialNo DisplayString, cpqSiMemModuleECCStatus INTEGER } cpqSiMemBoardIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the memory board is installed." ::= { cpqSiMemModuleEntry 1 } cpqSiMemModuleIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module number." ::= { cpqSiMemModuleEntry 2 } cpqSiMemModuleSize OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Module memory size in kilobytes. A kilobyte of memory is defined as 1024 bytes." ::= { cpqSiMemModuleEntry 3 } cpqSiMemModuleType OBJECT-TYPE SYNTAX INTEGER { other(1), board(2), cpqSingleWidthModule(3), cpqDoubleWidthModule(4), simm(5), pcmcia(6), compaq-specific(7), dimm(8), smallOutlineDimm(9), rimm(10), srimm(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanently mounted (not modular) on a system board or memory expansion board." ::= { cpqSiMemModuleEntry 4 } cpqSiMemModuleSpeed OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Module memory speed in nanoseconds. The value zero (0) will be given if the module speed cannot be determined." ::= { cpqSiMemModuleEntry 5 } cpqSiMemModuleTechnology OBJECT-TYPE SYNTAX INTEGER { other(1), fastPageMode(2), edoPageMode(3), burstEdoPageMode(4), synchronous(5), rdram(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Technology type of memory module installed. The value other(1) will be given if the technology is not known." ::= { cpqSiMemModuleEntry 6 } cpqSiMemModuleManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module's manufacturer name. This field will be a null (size 0) string if the manufacturer name is not available." ::= { cpqSiMemModuleEntry 7 } cpqSiMemModulePartNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available." ::= { cpqSiMemModuleEntry 8 } cpqSiMemModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the date of manufacture is not available. The hour, minute, and second field will always be set to 0." ::= { cpqSiMemModuleEntry 9 } cpqSiMemModuleSerialNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The memory module's serial number. This field will be a null (size 0) string if the serial number is not available." ::= { cpqSiMemModuleEntry 10 } cpqSiMemModuleECCStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), degradedModuleIndexUnknown(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not supported on this memory module. ok(2): The correctable error count is below threshold. degraded(3): The correctable error count has exceeded threshold. degradedModuleIndexUnknown(4): The correctable error count has exceeded threshold. The module index not available." ::= { cpqSiMemModuleEntry 11 } -- **************************************************************************** -- Compaq System Information System Board Group -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4) -- -- -- **************************************************************************** cpqSiSystemId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Compaq System ID. This value indicates the Compaq system ID of the system board in this system. This ID replaces the product ID used in older machines (cpqSiProductId). A value of 7Eh for the cpqSiProductId indicates that the cpqSiSystemId should be used to identify the Compaq system. A value of zero (0) indicates that the system ID function is not supported on this machine. In this case, the cpqSiProductId should be used to identify the system." ::= { cpqSiSystemBoard 6 } cpqSiSystemCpuId OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Compaq System ID : CPU Component. This value indicates the CPU type of the system board in this system. A value of zero (0) indicates that the CPU type cannot be determined." ::= { cpqSiSystemBoard 7 } cpqSiFlashRomSupport OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), supported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates if this system supports flash upgradable system ROM." ::= { cpqSiSystemBoard 8 } cpqSiQuickTestRomDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the date of the current quick test ROM image. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if quick test ROM is not present. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first." ::= { cpqSiSystemBoard 9 } cpqSiReboot OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), available(2), defaultOnlyAvailable(3), rebootToCpqUtils(2693), rebootToDefault(8115), autoShutdown(9037) } ACCESS read-write STATUS deprecated DESCRIPTION "This object may contain the following values: notAvailable(1) the system does not support the reboot functionality. Setting this object to notAvailable(1) has no effect. available(2) the system supports the both reboot to functionalities. Setting this object to available(2) has no effect. defaultOnlyAvailable(3) the system supports the only the default reboot functionality. Setting this object to available(3) has no effect. rebootToCpqUtils(2693) the system will reboot to the Compaq Utilities if the reboot functionality is available. If possible, the agent will attempt to gracefully shutdown the operating system before performing the reboot. If this functionality is unavailable on this system then all sets will have no effect. rebootToDefault(8115) the system will reboot and allow the default boot process to occur if the reboot functionality is available. If possible, the agent will attempt to gracefully shutdown the operating system before performing the reboot. If this functionality is unavailable on this system then all sets will have no effect. autoShutdown(9037) If possible, the agent will attempt to gracefully shutdown the operating system. The agent will not preform a reboot. " ::= { cpqSiSystemBoard 10 } -- **************************************************************************** -- Compaq System Information Processor Microcode Patch Table -- ========================================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4) -- cpqSiProcMicroPatchTable (1.3.6.1.4.1.232.2.2.4.11) -- cpqSiProcMicroPatchEntry (1.3.6.1.4.1.232.2.2.4.11.1) -- -- **************************************************************************** cpqSiProcMicroPatchTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiProcMicroPatchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table lists the set of processor microcode patches that the system ROM contains. During post, the ROM will apply the appropriate patches to the CPU microcode. Scan this table to ensure that a patch is being applied to a processor." ::= { cpqSiSystemBoard 11 } cpqSiProcMicroPatchEntry OBJECT-TYPE SYNTAX CpqSiProcMicroPatchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry describing one microcode patch contained in the system ROM." INDEX { cpqSiProcMicroPatchIndex } ::= { cpqSiProcMicroPatchTable 1 } CpqSiProcMicroPatchEntry ::= SEQUENCE { cpqSiProcMicroPatchIndex INTEGER, cpqSiProcMicroPatchId INTEGER, cpqSiProcMicroPatchDate OCTET STRING, cpqSiProcMicroPatchFamily OCTET STRING } cpqSiProcMicroPatchIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index into the microcode patch table." ::= { cpqSiProcMicroPatchEntry 1 } cpqSiProcMicroPatchId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ID of this particular CPU microcode patch." ::= { cpqSiProcMicroPatchEntry 2 } cpqSiProcMicroPatchDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the date of this CPU microcode patch. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) NOTE: Year is stored in packed BCD. The most significant part is in the second octet. For example: 1995 would be stored as 0x95 0x19. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first." ::= { cpqSiProcMicroPatchEntry 3 } cpqSiProcMicroPatchFamily OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) ACCESS read-only STATUS mandatory DESCRIPTION "The valid family/model/step of the processor that this CPU microcode patch applies to. field octets contents range ===== ====== ======= ===== 1 1 CPU Step 0..255 2 2 CPU Model 0..255 3 3 CPU Family 0..255 " ::= { cpqSiProcMicroPatchEntry 4 } -- **************************************************************************** -- Compaq System Information System Board Group -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4) -- -- -- **************************************************************************** cpqSiPowerMgmtStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of power management." ::= { cpqSiSystemBoard 12 } cpqSiRebootFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Reboot Flags. This is a collection of flags used to indicate the re-boot options available. This integer is a bitmap, with each bit indicating the availability of an option. If the bit is set to 1, the option is available; otherwise it is not. Multiple options are allowed. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. Status This is a collection of flags. Each bit has the following meaning when it is on (1): Bit 31: Execute Set Bit 30-4: RESERVED Bit 3: Boot to OS Bit 2: Boot to Utils Bit 1: Warm Boot Bit 0: Cold Boot " ::= { cpqSiSystemBoard 13 } cpqSiMemErrorIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Placeholder for memory module number for ECC traps. Represents the number of the memory module for which an ECC status change has occured. Set to 65535 if module number not available." ::= { cpqSiSystemBoard 14 } cpqSiMemECCCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current condition of the correctable memory errors for the entire memory. The following status values are supported: other(1) : ECC is not supported. ok(2) : The correctable error count is below threshold. degraded(3) : The correctable error count has exceeded threshold." ::= { cpqSiSystemBoard 15 } cpqSiMemConfigChangeData OBJECT-TYPE SYNTAX DisplayString (SIZE (0..383)) ACCESS read-only STATUS mandatory DESCRIPTION "Text string for the memory configuration change trap." ::= { cpqSiSystemBoard 16 } -- **************************************************************************** -- Compaq System Information Board Revision Group -- ============================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5) -- -- The cpqSiBoardRev group describes the board revision information. -- -- Implementation of the cpqSiBoardRev group is mandatory for all -- agents that support the Compaq System Information MIB in a system that -- supports the board revision feature. -- -- **************************************************************************** cpqSiCurRevDate OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The current board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the current configuration. This value will contain 'N/A' if this system does not support this feature." ::= { cpqSiBoardRev 1 } cpqSiPrevRevDate OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The previous board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the previous configuration. This value will contain 'N/A' if this system does not support this feature." ::= { cpqSiBoardRev 2 } -- **************************************************************************** -- Compaq System Information Board Revision Table -- ============================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5) -- cpqSiBoardRevTable (1.3.6.1.4.1.232.2.2.5.3) -- -- **************************************************************************** cpqSiBoardRevTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiBoardRevEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of board revision descriptions." ::= { cpqSiBoardRev 3 } cpqSiBoardRevEntry OBJECT-TYPE SYNTAX CpqSiBoardRevEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A board revision description." INDEX { cpqSiBoardRevSlotIndex, cpqSiBoardRevIndex } ::= { cpqSiBoardRevTable 1 } CpqSiBoardRevEntry ::= SEQUENCE { cpqSiBoardRevSlotIndex INTEGER, cpqSiBoardRevIndex INTEGER, cpqSiBoardRevId DisplayString, cpqSiBoardRevCur DisplayString, cpqSiBoardRevPrev DisplayString } cpqSiBoardRevSlotIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The slot in which the board described in this entry resides. Zero (0) indicates the system board." ::= { cpqSiBoardRevEntry 1 } cpqSiBoardRevIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A number that uniquely specifies which board in a specific slot is described in this entry. Zero (0) indicates the main board in this slot. Any other number indicates a daughter board or a component of the main board." ::= { cpqSiBoardRevEntry 2 } cpqSiBoardRevId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "A description of the board type. The defined types are: Type ============== System Board Processor n (n = the processor number) Memory n (n = the memory board number) Slot n (n = the slot the board occupies) Other types may be defined at a later date." ::= { cpqSiBoardRevEntry 3 } cpqSiBoardRevCur OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The current revision for the board described in this entry. This value will be N/A if there is no current revision information." ::= { cpqSiBoardRevEntry 4 } cpqSiBoardRevPrev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The revision for the board described in this entry prior to the current configuration. This value will be N/A if there is no previous revision information." ::= { cpqSiBoardRevEntry 5 } -- **************************************************************************** -- Compaq System Information Ups Shutdown Group -- ============================================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiRackServer Group (1.3.6.1.4.1.232.2.2.6) -- -- The cpqSiRackServer group describes this system's role in a rack -- family. -- -- Implementation of the cpqSiRackServer group is mandatory for all -- agents that support the Compaq System Information MIB in a system that -- supports Rack Server features. -- -- **************************************************************************** cpqSiRackServerShutdownRole OBJECT-TYPE SYNTAX INTEGER { other(1), master(2), slave(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This entry describes this system's role in a rack-mounted uninterruptable power supply family. The master both communicates with the UPS and derives its power from the UPS. The slave derives its power from the UPS, but does not communicate with it." ::= { cpqSiRackServer 1 } cpqSiRackServerMasterName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) ACCESS read-write STATUS mandatory DESCRIPTION "This entry describes the name of the master server in a rack-mounted uninterruptable power supply family. A slave system would communicate with this server to derive UPS status." ::= { cpqSiRackServer 2 } -- **************************************************************************** -- Compaq System Information Video Group -- ===================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiVideo Group (1.3.6.1.4.1.232.2.2.7) -- -- The Video group describes the Compaq manageable video displays that is -- attached to the system. -- -- Implementation of the video group is mandatory for all agents that -- support the Compaq System Information MIB when a Compaq manageable -- video display is in the system. -- -- **************************************************************************** cpqSiVideoEdidRaw OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) ACCESS read-only STATUS deprecated DESCRIPTION "The raw value returned from the video EDID function." ::= { cpqSiVideo 1 } cpqSiVideoDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS deprecated DESCRIPTION "The manufacturer and model description of the video display." ::= { cpqSiVideo 2 } cpqSiVideoSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS deprecated DESCRIPTION "The serial number of the video display." ::= { cpqSiVideo 3 } cpqSiVideoManufactureDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS deprecated DESCRIPTION "The date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date. The date information that is given resolves to a year and week, so the hour, minute, and second field will be set to 0, the month and day fields will give the monday of the week of manufacture." ::= { cpqSiVideo 4 } cpqSiVideoHeight OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "The maximum image height of the video display in centimeters" ::= { cpqSiVideo 5 } cpqSiVideoWidth OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS deprecated DESCRIPTION "The maximum image width of the video display in centimeters" ::= { cpqSiVideo 6 } cpqSiVideoMaxHorPixel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "The number of horizontal pixels in the highest resolution video mode supported." ::= { cpqSiVideo 7 } cpqSiVideoMaxVertPixel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "The number of vertical pixels in the highest resolution video mode supported." ::= { cpqSiVideo 8 } cpqSiVideoMaxRefreshRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS deprecated DESCRIPTION "The video refresh rate in Hz of the highest resolution video mode supported." ::= { cpqSiVideo 9 } -- **************************************************************************** -- Compaq System Information Monitor Group -- ======================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8) -- -- The Monitor group describes all Compaq manageable video displays -- that are attached to the system. -- -- Implementation of the monitor group is mandatory for all agents that -- support the Compaq System Information MIB when a Compaq manageable -- video display is in the system. -- -- **************************************************************************** cpqSiMonitorOverallCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the system's monitor(s). The following conditions are supported: other(1) The monitor does not support fault reporting or condition is unknown. ok(2) The monitor is operating OK. degraded(3) The monitor has detected a fault. The monitor is still useable but action should be taken to return the monitor to ok. failed(4) The monitor has detected a fault. The monitor will not be useable. Action should be taken to replace the monitor." ::= { cpqSiMonitor 1 } -- **************************************************************************** -- Compaq System Information Monitor Group -- ======================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8) -- cpqSiMonitorTable (1.3.6.1.4.1.232.2.2.8.2) -- cpqSiMonitorEntry (1.3.6.1.4.1.232.2.2.8.2.1) -- -- The Monitor Table describes all Compaq manageable video displays -- that are attached to the system. -- -- **************************************************************************** cpqSiMonitorTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiMonitorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of all video monitor descriptions connected to this system." ::= { cpqSiMonitor 2 } cpqSiMonitorEntry OBJECT-TYPE SYNTAX CpqSiMonitorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A video monitor description." INDEX { cpqSiMonitorIndex } ::= { cpqSiMonitorTable 1 } CpqSiMonitorEntry ::= SEQUENCE { cpqSiMonitorIndex INTEGER, cpqSiMonitorEdidRaw OCTET STRING, cpqSiMonitorDesc DisplayString, cpqSiMonitorSerialNumber DisplayString, cpqSiMonitorManufactureDate OCTET STRING, cpqSiMonitorHeight INTEGER, cpqSiMonitorWidth INTEGER, cpqSiMonitorMaxHorPixel INTEGER, cpqSiMonitorMaxVertPixel INTEGER, cpqSiMonitorMaxRefreshRate INTEGER, cpqSiMonitorManufacturer DisplayString, cpqSiMonitorThermalCondition INTEGER, cpqSiMonitorOperationalCondition INTEGER, cpqSiMonitorStatus INTEGER } cpqSiMonitorIndex OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for each video display connected to the system." ::= { cpqSiMonitorEntry 1 } cpqSiMonitorEdidRaw OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) ACCESS read-only STATUS mandatory DESCRIPTION "The raw value returned from the video EDID function." ::= { cpqSiMonitorEntry 2 } cpqSiMonitorDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturer and model description of the video display." ::= { cpqSiMonitorEntry 3 } cpqSiMonitorSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of the video display." ::= { cpqSiMonitorEntry 4 } cpqSiMonitorManufactureDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date. The date information that is given resolves to a year and week, so the hour, minute, and second field will be set to 0, the month and day fields will give the monday of the week of manufacture." ::= { cpqSiMonitorEntry 5 } cpqSiMonitorHeight OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum image height of the video display in centimeters" ::= { cpqSiMonitorEntry 6} cpqSiMonitorWidth OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum image width of the video display in centimeters" ::= { cpqSiMonitorEntry 7 } cpqSiMonitorMaxHorPixel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of horizontal pixels in the highest resolution video mode supported." ::= { cpqSiMonitorEntry 8 } cpqSiMonitorMaxVertPixel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of vertical pixels in the highest resolution video mode supported." ::= { cpqSiMonitorEntry 9 } cpqSiMonitorMaxRefreshRate OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The video refresh rate in Hz of the highest resolution video mode supported." ::= { cpqSiMonitorEntry 10 } cpqSiMonitorManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturer of the video display." ::= { cpqSiMonitorEntry 11 } cpqSiMonitorThermalCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the condition of the monitor’s internal temperature. This value will be one of the following: other(1) Monitor thermal fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. ok(2) The internal temperature is within normal limits. degraded(3) The internal temperature is outside normal operating range." ::= { cpqSiMonitorEntry 12 } cpqSiMonitorOperationalCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the condition of the monitor's operational features. This condition value will be one of the following: other(1) Monitor operational fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. ok(2) The monitor is operating within normal limits. degraded(3) The monitor is not functioning within normal operating limits. At least one of the opertional features has become degraded. failed(4) The monitor is not functioning within normal operating limits. At least one of the operational features has failed causing the monitor to not be usable. The monitor should be replaced." ::= { cpqSiMonitorEntry 13 } cpqSiMonitorStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), ok(3), thermalDegraded(4), operationalFailure(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the status of the monitor's fault reporting features. This status value will be one of the following: other(1) Monitor fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. unknown(2) The monitor status is unknown because the monitor is either in power saving mode or it has been turned off. ok(3) The monitor is operating within normal limits. thermalDegraded(4) The monitor's internal temperature is not functioning within normal operating limits. operationalFailure(5) The monitor is not functioning within normal operating limits. At least one of the operational features has failed. The monitor should be replaced." ::= { cpqSiMonitorEntry 14 } -- **************************************************************************** -- System Information Hot Plug Slot Group -- ====================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9) -- -- The cpqSiHotPlugSlot group describes the System Information Hot Plug -- slot information. -- -- Implementation of the cpqSiHotPlugSlot group is mandatory for all -- agents that support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiHotPlugSlotSupported OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), supported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies if this system supports the Hot Pluggable Slot feature." ::= { cpqSiHotPlugSlot 1 } cpqSiHotPlugSlotCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of the Hot Plug Slot feature. The Hot Plug condition is set as follows: other(1) When Hot Plug Slots are not supported or condition is unknown. ok(2) If there are no hot plug slots with a condition of degraded or failed. degraded(3) If there are degraded slot entries but none failed. failed(4) If there are failed slot entries." ::= { cpqSiHotPlugSlot 2 } cpqSiHotPlugSlotChangeCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value will be incremented each time a hot plug event occurs resulting in a change in the hot plug slot table." ::= { cpqSiHotPlugSlot 3 } -- **************************************************************************** -- System Information Hot Plug Slot Table -- ====================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9) -- cpqSiHotPlugSlotTable (1.3.6.1.4.1.232.2.2.9.4) -- -- The cpqSiHotPlugSlot group describes the Compaq manageable Hot Plug -- Slots in the system. This table will be missing is the system does -- not support hot plug slots. -- -- **************************************************************************** cpqSiHotPlugSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiHotPlugSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Hot Plug Slot information entries." ::= { cpqSiHotPlugSlot 4 } cpqSiHotPlugSlotEntry OBJECT-TYPE SYNTAX CpqSiHotPlugSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a Hot Plug Slot." INDEX { cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex } ::= { cpqSiHotPlugSlotTable 1 } CpqSiHotPlugSlotEntry ::= SEQUENCE { cpqSiHotPlugSlotChassis INTEGER, cpqSiHotPlugSlotIndex INTEGER, cpqSiHotPlugSlotBoardPresent INTEGER, cpqSiHotPlugSlotPowerState INTEGER, cpqSiHotPlugSlotBoardCondition INTEGER, cpqSiHotPlugSlotErrorStatus INTEGER } cpqSiHotPlugSlotChassis OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The Chassis where this hot plug slot resides." ::= { cpqSiHotPlugSlotEntry 1 } cpqSiHotPlugSlotIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The slot within the chassis for this hot plug slot." ::= { cpqSiHotPlugSlotEntry 2 } cpqSiHotPlugSlotBoardPresent OBJECT-TYPE SYNTAX INTEGER { other(1), present(2), absent(3), presentButSuspended(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates whether a board is present(2) in or absent(3) from the slot. A value of other(1) indicates the information could not be obtained." ::= { cpqSiHotPlugSlotEntry 3 } cpqSiHotPlugSlotPowerState OBJECT-TYPE SYNTAX INTEGER { other(1), powerOn(2), powerOff(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value is set to powerOn(2) when power is being supplied to the slot and powerOff(3) when power is not being supplied. A value of other(1) indicates the information could not be obtained." ::= { cpqSiHotPlugSlotEntry 4 } cpqSiHotPlugSlotBoardCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the condition of the hot plug slot. The hot plug condition is set as follows: other(1) When the condition could not be determined. ok(2) The slot is powered up and operating normally. degraded(3) If the board in the slot is not fully functioning. failed(4) If the slot is failed for any reason. See the status code for more information on the failure." ::= { cpqSiHotPlugSlotEntry 5 } cpqSiHotPlugSlotErrorStatus OBJECT-TYPE SYNTAX INTEGER { noError(1), generalError(2), wrongRevision(3), wrongBoard(4), cannotConfig(5), powerFault(6), unexpectedPowerLoss(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the status of the hot plug slot. The hot plug status is set as follows: noError(1) The slot is operating normally. generalError(2) A general error occurred. wrongRevision(3) The revision of the replacement board was different from the original board. wrongBoard(4) The model of the replacement board was different from the original board. cannotConfig(5) The board could not be configured. powerFault(6) A power fault occurred for the slot. unexpectedPowerLoss(7) Power was unexpectedly lost from the slot." ::= { cpqSiHotPlugSlotEntry 6 } -- **************************************************************************** -- System Information System Battery Group -- ======================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10) -- -- The cpqSiSystemBattery group describes information about the system -- (protable) batteries that are used to power your system. These -- are the rechargeable batteries. -- -- -- Implementation of the cpqSiBattery group is mandatory for all -- agents that support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiSystemBatteryOverallCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall condition of all of the system batteries. The following conditions are supported: other(1) The system does not use system batteries or the battery condition is unknown. ok(2) All System Batteries are operating OK. degraded(3) One or more of the System Batteries has degraded. The degraded battery will continue to function but should be replaced. failed(4) One of more of the System Batteries has failed. The failed battery is no longer usable. Action should be taken to replace the battery." ::= { cpqSiSystemBattery 1 } -- **************************************************************************** -- System Information System Battery Group -- ======================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10) -- cpqSiSystemBatteryTable (1.3.6.1.4.1.232.2.2.10.2) -- cpqSiSystemBatteryEntry (1.3.6.1.4.1.232.2.2.10.2.1) -- -- The System Battery Table describes asset, physical, and status -- information about the portable batteries powering your system. -- -- **************************************************************************** cpqSiSysBatteryTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSiSysBatteryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of System Batteries." ::= { cpqSiSystemBattery 2 } cpqSiSysBatteryEntry OBJECT-TYPE SYNTAX CpqSiSysBatteryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A system battery description." INDEX { cpqSiSysBatteryIndex } ::= { cpqSiSysBatteryTable 1 } CpqSiSysBatteryEntry ::= SEQUENCE { cpqSiSysBatteryIndex INTEGER, cpqSiSysBatteryModel DisplayString, cpqSiSysBatterySerialNum DisplayString, cpqSiSysBatteryAssetTag DisplayString, cpqSiSysBatteryManufacturer DisplayString, cpqSiSysBatteryDate OCTET STRING, cpqSiSysBatterySmartVersion DisplayString, cpqSiSysBatteryCondition INTEGER, cpqSiSysBatteryStatus INTEGER, cpqSiSysBatteryChemistry INTEGER, cpqSiSysBatteryRemainingCap INTEGER, cpqSiSysBatteryFirmwareRevision INTEGER, cpqSiSysBatteryHardwareRevision INTEGER, cpqSiSysBatteryFullCap INTEGER, cpqSiSysBatteryDesignCap INTEGER } cpqSiSysBatteryIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for this battery entry." ::= { cpqSiSysBatteryEntry 1 } cpqSiSysBatteryModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The model name for this battery." ::= { cpqSiSysBatteryEntry 2 } cpqSiSysBatterySerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number for this battery." ::= { cpqSiSysBatteryEntry 3 } cpqSiSysBatteryAssetTag OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the customer changeable battery identifier that is set to this system battery's serial number at the time of manufacture. The string will be empty if the battery does support this function." ::= { cpqSiSysBatteryEntry 4 } cpqSiSysBatteryManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The battery's manufacturer's name. The string will be empty if the battery does support this function." ::= { cpqSiSysBatteryEntry 5 } cpqSiSysBatteryDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-only STATUS mandatory DESCRIPTION "The battery's manufacture date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first. The string will be empty if the battery does support this function." ::= { cpqSiSysBatteryEntry 6 } cpqSiSysBatterySmartVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The Smart Battery Data Specification version number supported by this battery. The string will be empty if the system battery does support this function." ::= { cpqSiSysBatteryEntry 7 } cpqSiSysBatteryCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current condition of this system battery. The following status values are supported: other(1) The battery does not support condition monitoring or the Insight Agent cannot determine condition. ok(2) The battery is operating normally. No user action is required. degraded(3) The battery is degraded. The battery is still usable but should be replaced. failed(4) The battery has failed. The battery is no longer usable and should be replaced soon." ::= { cpqSiSysBatteryEntry 8 } cpqSiSysBatteryStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), capacityDegraded(3), chargeFault(4), batteryFailure(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This provides the current status of the battery. The following status values are supported: other(1): This battery does not support status reporting. ok(2): The battery is operating ok. User Action: No action required. capacityDegraded(3): Significant battery degradation has occurred. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery. chargeFault(4): One or more batteries are not functioning properly. User Action: Make sure all batteries are operating in the recommended temperature range. Check for foreign objects in the battery slots. Remove and reinsert all batteries to resume normal battery operation. Contact your System Administrator or Compaq Authorized Reseller if you are still experiencing problems. batteryFailure(5): The battery has failed and must be replaced. User Action: Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery. Recycle your old battery. For proper disposal information, refer to the documentation that came with your computer." ::= { cpqSiSysBatteryEntry 9 } cpqSiSysBatteryChemistry OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), lead-Acid(3), nickel-Cadmium(4), nickel-Metal-Hydride(5), lithium-Ion(6), zinc-Air(7), lithium-Polymer(8) } ACCESS read-only STATUS mandatory DESCRIPTION "The chemistry of the battery." ::= { cpqSiSysBatteryEntry 10 } cpqSiSysBatteryRemainingCap OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This is a percentage of the battery's remaining capacity from its design capacity. If this attribute is not supported, 65535 is returned." ::= { cpqSiSysBatteryEntry 11 } cpqSiSysBatteryFirmwareRevision OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is the revision level of the firmware on the battery. If this attribute is not supported, 255 is returned." ::= { cpqSiSysBatteryEntry 12 } cpqSiSysBatteryHardwareRevision OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is the revision level of the hardware on the battery. If this attribute is not supported, 255 is returned." ::= { cpqSiSysBatteryEntry 13 } cpqSiSysBatteryFullCap OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This is the mWatt-Hours of the battery's Full capacity on the current charge. If this attribute is not supported, 65535 is returned." ::= { cpqSiSysBatteryEntry 14 } cpqSiSysBatteryDesignCap OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This is the mWatt-Hours of the battery's design capacity as specified by the manufacturer. If this attribute is not supported, 65535 is returned." ::= { cpqSiSysBatteryEntry 15 } -- **************************************************************************** -- System Information Docking Station Group -- ======================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSystemInfo Group (1.3.6.1.4.1.232.2) -- cpqSiComponent Group (1.3.6.1.4.1.232.2.2) -- cpqSiDockingStation Group (1.3.6.1.4.1.232.2.2.11) -- -- The cpqsiDockingStation group describes the asset information -- about portable docking stations. -- -- -- Implementation of the cpqSiDockingStation group is mandatory for all -- agents that support the Compaq System Information MIB. -- -- **************************************************************************** cpqSiDockingStationStatus OBJECT-TYPE SYNTAX INTEGER { notSupported(1), docked(2), undocked(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the connection of the computer system to a docking station. The following connection states are supported: notSupported(1) This system does not interface to a docking station. docked(2) This system is connected to a docking station. undocked(3) This system is not connect to a docking station." ::= { cpqSiDockingStation 1} cpqSiDockingStationSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of the docking station. The string will be empty if the docking station does not support a serial or the system does not interface to a docking station." ::= { cpqSiDockingStation 2 } cpqSiDockingStationModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The model name of the docking station. The string will be empty if the docking station does not report the model name or the system does not interface to a docking station." ::= { cpqSiDockingStation 3 } cpqSiDockingStationAssetTag OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This is a customer changeable identifier that is set to the docking station serial number at the time of manufacture. The string will be empty if the docking station does not report an asset tag or the system does not interface to a docking station." ::= { cpqSiDockingStation 4} -- **************************************************************************** -- System Info MIB Trap Definitions -- ================================ -- -- The SNMP trap messages must not be bigger than 484 octets (bytes). -- -- Trap support in an SNMP agent implementation is optional. An SNMP -- agent implementation may support all, some, or none of the traps. -- If traps are supported, The user should be provided with the option of -- disabling traps. -- ************************************************************************** cpqSiHoodRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "System hood is removed. The hood status has been set to removed. The system's hood is not in a properly installed state. This situation may result in improper cooling of the system due to air flow changes caused by the missing hood. User Action: Replace the cover (hood), ensure the system's cover is properly installed. Verify the system is in working order." --#TYPE "System hood is removed" --#SUMMARY "Hood is removed from unit." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2001 cpqSiMonitorConditionOK TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } DESCRIPTION "Fault reporting features have returned to within their normal operating range for the monitor indicated by cpqSiMonitorIndex. The monitor's condition has been set to OK. User Action: None." --#TYPE "Monitor Condition OK" --#SUMMARY "The monitor's condition has been set to OK." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 2002 cpqSiMonitorConditionDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } DESCRIPTION "A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued." --#TYPE "Monitor Condition Degraded" --#SUMMARY "The monitor's condition has been set to degraded." --#ARGUMENTS {} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2003 cpqSiMonitorConditionFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex } DESCRIPTION "A fault reporting feature has exceeded normal limits in the monitor indicated by the cpqSiMonitorIndex. The monitor's condition has been set to failed due to an operational feature exceeding normal operating limits. The monitor will not be useable and should be replaced. User Action: Make a note of the monitor model number and serial number. Replace the monitor. Refer to the appropriate Maintenance and Service Guide for detailed information on a component replacement." --#TYPE "Monitor Condition Failed" --#SUMMARY "The monitor's condition has been set to failed." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL ::= 2004 cpqSiCorrMemErrStatusDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex } DESCRIPTION "Correctable memory error count has exceeded the threshold for the memory module indicated by the 'cpqSiMemErrorIndex' variable. The appropriate cpqSiMemModuleECCStatus has been set to degraded. User Action: For Desktops, the System Administrator should run the F10 Diagnostics on this system and select RAM LONG TEST. If it is determined that a module needs replacing, schedule maintenance for the system and replace the failed memory module. Refer to the appropriate Maintenance and Service Guide for detailed information on a component replacement." --#TYPE "Excessive Correctable Memory Errors" --#SUMMARY "The Memory Module %d ECC status has been set to degraded." --#ARGUMENTS {3} --#SEVERITY MINOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2005 cpqSiCorrMemErrStatusOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex } DESCRIPTION "Correctable memory error count is now below the threshold for the memory module indicated by the 'cpqSiMemErrorIndex' variable. The appropriate cpqSiMemModuleECCStatus has been set to ok. User Action: None." --#TYPE "Correctable Memory Errors Count OK" --#SUMMARY "The Memory Module %d ECC status has been set to OK." --#ARGUMENTS {3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 2006 cpqSiMemConfigChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemConfigChangeData } DESCRIPTION "A memory configuration change has occured. CpqSiMemConfigChangeData will indicate which memory modules slots have changed. User Action: You may want to verify a valid reason for a memory configuration to have occurred. If system issuing the alert is a Desktop running NT, the memory configuration change information is also logged in the NT System Log." --#TYPE "Memory modules have changed" --#SUMMARY "The system's memory configuration has changed." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 2007 cpqSiHotPlugSlotBoardRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex } DESCRIPTION "Hot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified chassis and slot. User Action: None." --#TYPE "Hot Plug Slot Board Removed" --#SUMMARY "Hot Plug Slot Board Removed from Chassis %d, Slot %d." --#ARGUMENTS {2, 3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 2008 cpqSiHotPlugSlotBoardInserted TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex } DESCRIPTION "Hot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified chassis and slot. User Action: None." --#TYPE "Hot Plug Slot Board Inserted" --#SUMMARY "Hot Plug Slot Board Inserted into Chassis %d, Slot %d." --#ARGUMENTS {2, 3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 2009 cpqSiHotPlugSlotPowerUpFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex, cpqSiHotPlugSlotErrorStatus } DESCRIPTION "Hot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power-up in the specified chassis and slot. User Action: Insure the board and all cables are installed correctly and the board type and revision are the same as the replaced board." --#TYPE "Hot Plug Slot Board Failed" --#SUMMARY "Hot Plug Slot Board Failed in Chassis %d, Slot %d, Error %d." --#ARGUMENTS {2, 3, 4} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE FAILED ::= 2010 cpqSiSysBatteryFailure TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex, cpqSiSysBatterySerialNum } DESCRIPTION "The battery indicated by cpqSiSysBatteryIndex has failed and must be replaced. User Action: Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery. Recycle your old battery. For proper disposal information, refer to the documentation that came with your computer." --#TYPE "Battery Failure" --#SUMMARY "Battery %d has failed." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2011 cpqSiSysBatteryChargingDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex, cpqSiSysBatterySerialNum } DESCRIPTION "Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery." --#TYPE "Battery Charging Degradation" --#SUMMARY "Battery %d has degraded charging capacity." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2012 cpqSiSysBatteryCalibrationError TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex, cpqSiSysBatterySerialNum } DESCRIPTION "Calibration is needed with battery indicated by cpqSiSysBatteryIndex. The battery can not correctly indicate capacity. User Action: Run Compaq Power Conservation Utility. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery." --#TYPE "Battery Calibration Error" --#SUMMARY "Battery %d has calibration error." --#ARGUMENTS {2} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 2013 END