AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CT-PIC-MIB

CT-PIC-MIB device MIB details by Enterasys Networks Inc

CT-PIC-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CT-PIC-MIB.


Vendor: Enterasys Networks Inc
Mib: CT-PIC-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CT-PIC-MIB DEFINITIONS ::= BEGIN
        --  ct-pic-mib
        --  Revision: 1.02.05
        --  Part Number: 2170997
        --  Date:  March 16, 2000

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for part
        --  of the naming tree below:
        --
        --              cabletron { enterprises 52 }
        --
        --  This module will be extended, as additional sub-sections
        --  of this naming tree are defined.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright March 2000 Cabletron Systems

-- PICs come in multiple types.  In general they define information which is
-- maintained by manufacturing and is updated whenever the  module is updated.
-- The other use for PICs is to hold other interesting information such as
-- MAC addresses etc.  In order to support this dual function this MIB
-- consists of 2 different tables.  The first ctPicTable calls out the
-- information that is defined by manufacturing which defines the particular
-- module the PIC resides on.  The second table ctPicTagTable defines the
-- other entries that may or maynot be  defined for the given module.  The
-- second table functions based on TAG id to define the location of the object
-- within the PIC and a TAG type field that defines the type of information
-- found in that field.

        IMPORTS
                Gauge           FROM RFC1155-SMI
                OBJECT-TYPE     FROM RFC-1212
                DisplayString   FROM RFC1213-MIB
                ctPIC           FROM CTRON-MIB-NAMES;

-- DisplayString ::= OCTET STRING

-- ctPIC MODULE-IDENTITY
--    LAST-UPDATED "000316184621Z"
--    ORGANIZATION "Cabletron Systems, Inc"
--    CONTACT-INFO
--    "Cabletron Systems, Inc.
--     35 Industrial Way, P.O. Box 5005
--     Rochester, NH 03867-0505
--     (603) 332-9400
--     support@cabletron.com
--     http://www.ctron.com"
--
--    DESCRIPTION
--            "This mib module defines a portion of the SNMP enterprise
--             MIBs under Cabletron enterprise OID pertaining to
--             the Product Information Chip (PIC)."
--
--    REVISION    "000316184621Z"
--    DESCRIPTION "Added enumerations newbridge(5) and enTeraSys(6) to the
--                 ctPicOEMVendorId leaf.  Added a commented out MODULE-IDENTITY 
--                 block to allow for better tracking of revisions."
--         ::= { ctSystem 9 }


pic     OBJECT IDENTIFIER ::= { ctPIC 1 }

ctPicNumberEntries      OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines the number of PIC modules defined by this MIB."
        ::= { pic 1 }

ctPicTable              OBJECT-TYPE
        SYNTAX  SEQUENCE OF CtPicEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A table that describes the contents of all PIC modules
                accessible by this module."
        ::= { pic 2 }

ctPicEntry              OBJECT-TYPE
        SYNTAX  CtPicEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Description of a specific instance of a PIC module."
        INDEX   { ctPicSlot, ctPicIndex }
        ::= { ctPicTable 1 }

CtPicEntry              ::= SEQUENCE {
        ctPicSlot
                INTEGER,
        ctPicIndex
                INTEGER,
        ctPicLocation
                OBJECT IDENTIFIER,
        ctPicStatus
                INTEGER,
        ctPicVersion
                DisplayString,
        ctPicModuleType
                OBJECT IDENTIFIER,
        ctPicMfgPN
                DisplayString,
        ctPicMfgSN
                DisplayString,
        ctPicMfgPartNumb
                DisplayString,
        ctPicMfgSerialNumb
                DisplayString,
        ctPicMfgReworkLocation
                DisplayString,
        ctPicMfgMfgLocation
                DisplayString,
        ctPicMfgDateCode
                DisplayString,
        ctPicMfgRevisionCode
                DisplayString,
        ctPicTLPN
                DisplayString,
        ctPicTLSN
                DisplayString,
        ctPicTLPartNumb
                DisplayString,
        ctPicTLSerialNumb
                DisplayString,
        ctPicTLReworkLocation
                DisplayString,
        ctPicTLMfgLocation
                DisplayString,
        ctPicTLDateCode
                DisplayString,
        ctPicTLRevisionCode
                DisplayString,
        ctPicPcbRevision
                DisplayString,
        ctPicMacAddr
                OCTET STRING,
        ctPicNumbRsvdAddrs
                INTEGER,
        ctPicBoardRevision
                DisplayString,
        ctPicModuleTypeString
                DisplayString,
        ctPicDCDCconverterType
                DisplayString,
        ctPicDCDCconvInputPower
                DisplayString,
        ctPicSMB1promVersion
                DisplayString,
        ctPicAtmMacAddr
                OCTET STRING,
        ctPicOEMVendorId
                INTEGER,
        ctPicOEMVendorName
                DisplayString,
        ctPicMfg97SN
                DisplayString,
        ctPicMfg97DateCode
                DisplayString,
        ctPicMfg97RevisionCode
                DisplayString,
        ctPicTL97SN
                DisplayString,
        ctPicTL97DateCode
                DisplayString,
        ctPicTL97RevisionCode
                DisplayString,
        ctPicOEMTLSN
                DisplayString
        }

ctPicSlot  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specific slot which the module that realizes this PIC
                resides.  If the PIC is associated with the chassis
                and not a specific module then this value will be 0."
        ::= { ctPicEntry 1 }

ctPicIndex              OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Uniquely identifies the instance of a PIC in a particular
                 slot."
        ::= { ctPicEntry 2 }

ctPicLocation           OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines location of the PIC chip.  This takes on any of
                the encoding values defined below for backplane, module,
                daughter board, brim."
        ::= { ctPicEntry 3 }

ctPicStatus             OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),
                        present(2),
                        notPresent(3),
                        checkSum(4),
                        error(5),
                        limited(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Provides the status of the specific PIC chip.  the values
                are defined as follows:
                        other(1) - firmware can not determine status
                        present(2) - PIC seems to be functional
                        notPresent(3) - PIC not found but expected
                        checkSum(4) - A check sum error occured
                        error(5) - An undefined error condition exists.
                        limited(6) - A limited PIC implementation only
                                type code information is present."
        ::= { ctPicEntry 4 }

ctPicVersion            OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Reflects the version of the PIC implementation that this
                PIC conforms to.  This has the format x.yy . If non-existent,
                this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 5 }

ctPicModuleType OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines the standard module type value as defined in
                ctron-oids."
        ::= { ctPicEntry 6 }

ctPicMfgPN      OBJECT-TYPE
        SYNTAX  DisplayString   (SIZE(9))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the manufacturing level part number of the module
                associated with this PIC.  This information is encoded as
                follows:
                        7 Characters    Part Number
                        2 Characters    Rework Location.
                If any field of this object is non-existent, it will be set
                to all blanks(ascii 32)."
        ::= { ctPicEntry 7 }

ctPicMfgSN      OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the manufacturing level serial number of the module
                associated with this PIC.  This information is encoded as
                follows:
                        3 bytes - Date code (year/week)
                        4 bytes - Serial number
                        2 bytes - Manufacture location
                        3 bytes - Board level revision
                If any field of this object is non-existent, it will be 
                set to all blanks(ascii 32)."
        ::= { ctPicEntry 8 }

ctPicMfgPartNumb        OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(7))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object presents the part number portion of the
                ctPicMfgPN object.  This object contains the same information
                however in a more human readable format.  If non-existent,
                this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 9 }

ctPicMfgSerialNumb      OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(4))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object presents the serial number portion of the
                ctPicMfgSN object.  This object contains the same information
                however in a more human readable format.  If non-existent,
                this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 10 }

ctPicMfgReworkLocation  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 2 character code that defines the location this
                module was last reworked. This object contains the same
                information as presented in ctPicMfgPN object however
                in a more human readable format.  If non-existent, this
                object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 11 }

ctPicMfgMfgLocation  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The two character code that defines the location
                this module was manufactured at. This object contains the same
                information as presented in ctPicMfgSN object however
                in a more human readable format.  If non-existent, this object 
                will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 12 }

ctPicMfgDateCode OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 3 byte date code field when this module was last
                reworked.  This is in year/week format. This object
                contains the same information as presented in ctPicMfgSN
                object however in a more human readable format.  If 
                non-existent, this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 13 }

ctPicMfgRevisionCode  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 3 character board level revision code field of this
                module.  This object contains the same information as
                presented in ctPicMfgSN object however in a more human
                readable format.  If non-existent, this object will be set
                to all blanks (ascii 32)."
        ::= { ctPicEntry 14 }

ctPicTLPN               OBJECT-TYPE
        SYNTAX  DisplayString   (SIZE(9))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the top level part number of the module associated
                with this PIC.  This information is encoded as follows:
                        7 Characters    Part Number
                        2 Characters    Rework Location.
                If any field of this object is non-existent, it will be set
                to all blanks(ascii 32)."
        ::= { ctPicEntry 15 }

ctPicTLSN       OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the top level serial number of the module
                associated with this PIC.  This information is encoded
                as follows:
                        3 bytes - Date code (year/week)
                        4 bytes - Serial number
                        2 bytes - Manufacture location
                        3 bytes - Top level revision
                If any field of this object is non-existent, it will be 
                set to all blanks(ascii 32)."
        ::= { ctPicEntry 16 }

ctPicTLPartNumb OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(7))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object presents the part number portion of the
                ctPicTLPN object.  This object contains the same information
                however in a more human readable format.  If non-existent,
                this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 17 }

ctPicTLSerialNumb       OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(4))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object presents the serial number portion of the
                ctPicTLSN object.  This object contains the same information
                however in a more human readable format.  If non-existent,
                this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 18 }

ctPicTLReworkLocation  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 2 character code that defines the location this
                module was last reworked. This object contains the same
                information as presented in ctPicTLPN object however
                in a more human readable format.  If non-existent, this
                object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 19 }

ctPicTLMfgLocation  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The two character code that defines the location
                this module was manufactured at. This object contains the same
                information as presented in ctPicTLSN object however
                in a more human readable format.  If non-existent, this object 
                will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 20 }

ctPicTLDateCode OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 3 byte date code field when this module was last
                reworked.  This is in year/week format. This object
                contains the same information as presented in ctPicTLSN
                object however in a more human readable format.  If 
                non-existent, this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 21 }

ctPicTLRevisionCode  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 3 character top level revision code field of this module.
                This object contains the same information as presented in
                ctPicTLSN object however in a more human readable format.
                If non-existent, this object will be set to all blanks
                (ascii 32)."
        ::= { ctPicEntry 22 }

ctPicPcbRevision        OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(8))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines the Cabletron revision of the art work for this
                module. If non-existent, this object will be set to all
                blanks(ascii 32)."
        ::= { ctPicEntry 23 }

ctPicMacAddr    OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE(0..6))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The base MAC address(ethernet format)assigned to the module.
                If this field is not used then it should have a value of a
                zero length string. If non-existent, this object will be set
                to all blanks(ascii 32)."
        ::= { ctPicEntry 24 }

ctPicNumbRsvdAddrs  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of reserved MAC addresses starting at the
                address as defined in ctPicMacAddr.  If no MAC addresses
                are reserved this object should have a value of 0."
        ::= { ctPicEntry 25 }

ctPicBoardRevision      OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines the Cabletron board level revision level code for
                this module.  If non-existent, this object will be set to
                blanks (ascii 32)."
        ::= { ctPicEntry 26 }

ctPicModuleTypeString   OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(16))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the module associated with this PIC in a 
                human readable format.  If non-existent, this object 
                will be set to blanks (ascii 32)."
        ::= { ctPicEntry 27 }

ctPicDCDCconverterType  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the voltage of the installed DCDC Converter 
                input and output lines.  
                If the Module does not contain a DCDC Converter
                this object will be set to blanks (ascii 32)."
        ::= { ctPicEntry 28 }

ctPicDCDCconvInputPower OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(3))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the maximum allowed input power 
                for the DCDC input line.
                If the Module does not contain a DCDC Converter
                this object will be set to blanks (ascii 32)."
        ::= { ctPicEntry 29 }

ctPicSMB1promVersion    OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(8))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the current version of the SMB1 prom. 
                If the Module does not contain an SMB1 prom
                this object will be set to blanks (ascii 32)."
        ::= { ctPicEntry 30 }

ctPicAtmMacAddr       OBJECT-TYPE
      SYNTAX  OCTET STRING (SIZE(0..20))
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
              "The Atm MAC address(atm format)assigned to the chassis.
              If this field is not used then it should have a value of a
              zero length string. If non-existent, this object will be set
              to all blanks(ascii 32)."
      ::= { ctPicEntry 31 }

ctPicOEMVendorId  OBJECT-TYPE
        SYNTAX  INTEGER {
          cabletron(1),
          nEC(2),
          dEC(3),
          cPQ(4),
          newbridge(5),
          enTeraSys(6)
          }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Represents the OEM vendor for a product.
                If the Module does not program this value
                this object will be set to blanks (ascii 32)."
        ::= { ctPicEntry 32 }

ctPicOEMVendorName      OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(40))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ASCII name of the OEM vendor for the product.
                If the Module does not program this value
                this object will be set to blanks (ascii 32)."
        ::= { ctPicEntry 33 }


ctPicMfg97SN    OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the manufacturing level serial number of the module
                associated with this PIC.  This information is encoded as
                follows:
                        4 bytes - Date code (year/week)
                        4 bytes - Serial number
                        2 bytes - Manufacture location
                        2 bytes - Board level revision
                If any field of this object is non-existent, it will be 
                set to all blanks(ascii 32)."
        ::= { ctPicEntry 34 }

ctPicMfg97DateCode OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(4))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 4 byte date code field when this module was last
                reworked.  This is in year/week format. This object
                contains the same information as presented in ctPicMfg97SN
                object however in a more human readable format.  If 
                non-existent, this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 35 }

ctPicMfg97RevisionCode  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 2 character board level revision code field of this
                module.  This object contains the same information as
                presented in ctPicMfg97SN object however in a more human
                readable format.  If non-existent, this object will be set
                to all blanks (ascii 32)."
        ::= { ctPicEntry 36 }

ctPicTL97SN     OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Describes the top level serial number of the module
                associated with this PIC.  This information is encoded
                as follows:
                        4 bytes - Date code (year/week)
                        4 bytes - Serial number
                        2 bytes - Manufacture location
                        2 bytes - Top level revision
                If any field of this object is non-existent, it will be 
                set to all blanks(ascii 32)."
        ::= { ctPicEntry 37 }

ctPicTL97DateCode OBJECT-TYPE 
        SYNTAX  DisplayString (SIZE(4))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 4 byte date code field when this module was last
                reworked.  This is in year/week format. This object
                contains the same information as presented in ctPicTL97SN
                object however in a more human readable format.  If 
                non-existent, this object will be set to all blanks(ascii 32)."
        ::= { ctPicEntry 38 }

ctPicTL97RevisionCode  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(2))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The 2 character top level revision code field of this module.
                This object contains the same information as presented in
                ctPicTL97SN object however in a more human readable format.
                If non-existent, this object will be set to all blanks
                (ascii 32)."
        ::= { ctPicEntry 39 }

ctPicOEMTLSN OBJECT-TYPE
        SYNTAX DisplayString (SIZE(20))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "Describes the top level serial number of the module as specified
                by the OEM for this device.  If non-existent, this object will be
                set to all blanks (ascii 32)."
        ::= { ctPicEntry 40 }


ctPicECOTable   OBJECT-TYPE
        SYNTAX  SEQUENCE OF CtPicECOEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Each module that contains a PIC may have several
                ECOs performed on it.  The ctPicECOTable reflects
                a history of the last 5 ECOs that have been performed
                on this module."
        ::= { pic 3 }

ctPicECOEntry   OBJECT-TYPE
        SYNTAX  CtPicECOEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Describes a particular PIC ECO entry."
        INDEX { ctPicECOSlot, ctPicECOIndex, ctPicECOID }
        ::= { ctPicECOTable 1 }

CtPicECOEntry   ::= SEQUENCE {
        ctPicECOSlot
                INTEGER,
        ctPicECOIndex
                INTEGER,
        ctPicECOID
                INTEGER,
        ctPicECONumber
                DisplayString
        }

ctPicECOSlot  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specific slot which the module that realizes this PIC
                resides.  If the PIC is associated with the chassis
                and not a specific module then this value will be 0.
                This refers to the same slot as identified by ctPicSlot
                in ctPicTable."
        ::= { ctPicECOEntry 1 }

ctPicECOIndex  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The specific PIC instance that this ECO entry pertains to.
                This refers to the same instance as identified by ctPicIndex
                in ctPicTable."
        ::= { ctPicECOEntry 2 }

ctPicECOID  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Uniquely defines the ECO entry that is being described
                by this conceptual row."
        ::= { ctPicECOEntry 3 }

ctPicECONumber  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(12))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines Cabletron's ECO number that describes the revision of
                the hardware.  This object is organized as follows:
                        6 Characters    ECO Number
                        2 Characters    Rework Location
                        4 Characters    Date Code"
        ::= { ctPicECOEntry 4 }


ctPicDiagTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF CtPicDiagEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Each module that contains a PIC may have several
                Diags performed on it.  The ctPicDiagTable reflects
                a history of the last 8 Diags that have been performed
                on this module.

                Important:  This table only contains entries diagnostic
                entries that are defined.  Therefore it is possible for
                this table to be empty 'does not respond to a GET or
                GET-NEXT' if there are no diagnostic errors present."
        ::= { pic 5 }

ctPicDiagEntry  OBJECT-TYPE
        SYNTAX  CtPicDiagEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Describes a particular PIC Diag entry."
        INDEX { ctPicDiagSlot, ctPicDiagIndex, ctPicDiagID }
        ::= { ctPicDiagTable 1 }

CtPicDiagEntry  ::= SEQUENCE {
        ctPicDiagSlot
                INTEGER,
        ctPicDiagIndex
                INTEGER,
        ctPicDiagID
                INTEGER,
        ctPicDiagResults
                DisplayString
        }

ctPicDiagSlot  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specific slot which the module that realizes this PIC
                resides.  If the PIC is associated with the chassis
                and not a specific module then this value will be 0.
                This refers to the same slot as identified by ctPicSlot
                in ctPicTable."
        ::= { ctPicDiagEntry 1 }

ctPicDiagIndex  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The specific PIC instance that this Diag entry pertains to.
                This refers to the same instance as identified by ctPicIndex
                in ctPicTable."
        ::= { ctPicDiagEntry 2 }

ctPicDiagID  OBJECT-TYPE
        SYNTAX  INTEGER (1..8)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Uniquely defines the Diag entry that is being described
                by this conceptual row."
        ::= { ctPicDiagEntry 3 }

ctPicDiagResults        OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(64))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Defines Cabletron's Diag results code."
        ::= { ctPicDiagEntry 4 }

-- The following is the control group for the PIC.
-- Currently only one object is defined for this group.

ctPicControlTable       OBJECT-TYPE
        SYNTAX  SEQUENCE OF CtPicControlEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A table allowing management control of PIC 
                 functionality. "
        ::= { pic 8 }

ctPicControlEntry       OBJECT-TYPE
        SYNTAX  CtPicControlEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Describes a particular PIC Control Table entry."
        INDEX { ctPicSlot, ctPicIndex }
        ::= { ctPicControlTable 1 }

CtPicControlEntry               ::= SEQUENCE {
        ctPicRefresh
                INTEGER
        }
 
ctPicRefresh   OBJECT-TYPE
        SYNTAX  INTEGER   {
                          reFresh(1)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Setting this value causes the PIC Driver to clear
                 cached memory and to reread the PIC chip.  This
                 functionality removes the need for manufacturing 
                 to power cycle a board to ensure proper PIC 
                 programming.  Reading this object always returns
                 a zero (0)."
        ::= { ctPicControlEntry 1 }


ctPicLocationID OBJECT IDENTIFIER ::= { pic 4 }
ctPicLocationModule OBJECT IDENTIFIER ::= { ctPicLocationID 1 }
ctPicBrim       OBJECT IDENTIFIER ::= { ctPicLocationID 2 }
ctPicChassis    OBJECT IDENTIFIER ::= { ctPicLocationID 3 }
ctPicDaughter   OBJECT IDENTIFIER ::= { ctPicLocationID 4 }
ctPicBackPlane  OBJECT IDENTIFIER ::= { ctPicLocationID 5 }

END