AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTRON-APPN-MIB

CTRON-APPN-MIB device MIB details by Enterasys Networks Inc

CTRON-APPN-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-APPN-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-APPN-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTRON-APPN-MIB  DEFINITIONS ::= BEGIN

--  ctron-appn-mib.txt
--  Revision: 1.00.03
--  Part Number: 2171066
--  Date: June 20, 1996

--  Cabletron Systems, Inc.
--  35 Industrial Way, P.O. Box 5005
--  Rochester, NH 03867-0505
--  (603) 332-9400
--  support@ctron.com

--  This module provides authoritative definitions for Cabletron's
--  enterprise specific APPN Routing Services MIB.
--
--
--  This module will be extended as required.
--
--  Cabletron Systems reserves the right to make changes in
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.


--  Copyright August 95 Cabletron Systems


IMPORTS
      OBJECT-TYPE
                FROM RFC-1212   
      nwRtrProtoSuites
                FROM ROUTER-OIDS
      DisplayString
                FROM RFC1213-MIB
      Counter, TimeTicks
                FROM RFC1155-SMI;

--  The APPN Router Group.

nwAppnRouter             OBJECT IDENTIFIER ::= { nwRtrProtoSuites 5 }

nwAppnMibs               OBJECT IDENTIFIER ::= { nwAppnRouter 1 }
nwAppnComponents         OBJECT IDENTIFIER ::= { nwAppnRouter 2 }

--  APPN Router Component Groups

nwAppnSystem             OBJECT IDENTIFIER ::= { nwAppnComponents 1 }
nwAppnForwarding         OBJECT IDENTIFIER ::= { nwAppnComponents 2 }
nwAppnTopology           OBJECT IDENTIFIER ::= { nwAppnComponents 4 }
nwAppnFib                OBJECT IDENTIFIER ::= { nwAppnComponents 5 }
nwAppnEndSystems         OBJECT IDENTIFIER ::= { nwAppnComponents 6 }
nwAppnAccessControl      OBJECT IDENTIFIER ::= { nwAppnComponents 7 }
nwAppnFilters            OBJECT IDENTIFIER ::= { nwAppnComponents 8 }
nwAppnRedirector         OBJECT IDENTIFIER ::= { nwAppnComponents 9 }
nwAppnEvent              OBJECT IDENTIFIER ::= { nwAppnComponents 10 }
nwAppnWorkGroup          OBJECT IDENTIFIER ::= { nwAppnComponents 11 }


--  APPN Router System Groups

nwAppnSysConfig          OBJECT IDENTIFIER ::= { nwAppnSystem 1 }
nwAppnSysAdministration  OBJECT IDENTIFIER ::= { nwAppnSystem 2 }

--  APPN Router System Configuration Groups

nwAppnSysCfgLocalNode    OBJECT IDENTIFIER ::= { nwAppnSysConfig 2 }
nwAppnSysCfgTables       OBJECT IDENTIFIER ::= { nwAppnSysConfig 3 }

--  APPN Router Forwarding Groups

nwAppnFwdSystem          OBJECT IDENTIFIER ::= { nwAppnForwarding 1 }
nwAppnFwdInterfaces      OBJECT IDENTIFIER ::= { nwAppnForwarding 2 }
nwAppnFwdLinks           OBJECT IDENTIFIER ::= { nwAppnForwarding 3 }

nwAppnFwdCounters        OBJECT IDENTIFIER ::= { nwAppnFwdSystem 1 }
nwAppnFwdIfConfig        OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 1 }
nwAppnIfCn               OBJECT IDENTIFIER ::= { nwAppnFwdIfConfig 3 }
nwAppnFwdIfCounters      OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 2 }
nwAppnFwdLsConfig        OBJECT IDENTIFIER ::= { nwAppnFwdLinks 1 }
nwAppnFwdLsCounters      OBJECT IDENTIFIER ::= { nwAppnFwdLinks 2 }


--  APPN Router Routing Groups

nwAppnDistanceVector     OBJECT IDENTIFIER ::= { nwAppnTopology 1 }
nwAppnLinkState          OBJECT IDENTIFIER ::= { nwAppnTopology 2 }

nwAppnIsr                OBJECT IDENTIFIER ::= { nwAppnLinkState 1 }

nwAppnIsrSystem          OBJECT IDENTIFIER ::= { nwAppnIsr 1 }
nwAppnIsrInterfaces      OBJECT IDENTIFIER ::= { nwAppnIsr 2 }
nwAppnIsrDatabase        OBJECT IDENTIFIER ::= { nwAppnIsr 3 }
nwAppnIsrFilters         OBJECT IDENTIFIER ::= { nwAppnIsr 4 }

nwAppnIsrConfig          OBJECT IDENTIFIER ::= { nwAppnIsrSystem 1 }
nwAppnIsrCounters        OBJECT IDENTIFIER ::= { nwAppnIsrSystem 2 }

nwAppnIsrIfConfig        OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 1 }
nwAppnIsrIfCounters      OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 2 }

--  APPN Router Host End Systems Groups  ( NOT USED )

nwAppnHostsSystem        OBJECT IDENTIFIER ::= { nwAppnEndSystems 1 }
nwAppnHostsInterfaces    OBJECT IDENTIFIER ::= { nwAppnEndSystems 2 }


--  APPN Router Event Log Group

nwAppnEventLogConfig           OBJECT IDENTIFIER ::= { nwAppnEvent 1 }
nwAppnEventLogFilterTable      OBJECT IDENTIFIER ::= { nwAppnEvent 2 }
nwAppnEventLogTable            OBJECT IDENTIFIER ::= { nwAppnEvent 3 }




--  APPN MIB Group
--  This group contains information about the revision level of this
--  MIB within the device.  It allows verification of the released
--  version without having to read other objects.

nwAppnMibRevText OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the current revision level of the Cabletron APPN 
                Router MIB in textual format." 
        ::= { nwAppnMibs 1 }


--  APPN Routing Services System Group
--  This group contains the objects related to APPN Routing Services at a
--  global system-wide level.

--  APPN Routing Services System Configuration Group
--  This group contains the objects that pertain to the setup and
--  configuration of APPN Routing Services at a global,
--  system-wide level.  

nwAppnSysRouterId   OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (3..17))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies the APPN Fully-Qualified Control Point name that is used
                to uniquely identify APPN Routing Services in an APPN network. The
                name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network
                identifier and CCCCCCCC is the Control Point name. Valid characters
                to make up these two strings are uppercase letters A through Z,
                numerics 0 through 9, and the special characters $, @, and #. The
                first character of the string must NOT be numeric. Each string must
                be a maximum length of 8 characters with no embedded spaces and the
                strings are joined by a dot. nwAppnSysRouterId cannot be modified
                while APPN routing services is in any operational state other than
                DISABLED as reflected in nwAppnSysOperStatus. Otherwise, the
                request will be rejected."
        ::= { nwAppnSysConfig 1 }



--  APPN Routing Services System Group
--  This group contains the objects related to initializing APPN Routing Services
--  at a global, system-wide level.
--  All parameters (except for Stop Type) cannot be modified unless the
--  operational state is disabled. Otherwise, the request will be rejected.

nwAppnSysNodeType   OBJECT-TYPE
        SYNTAX  INTEGER {
                        networknode(1)
                        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
               "Indicates the node type supported by APPN Routing Services which
                is always of type Network Node. "
        DEFVAL { networknode }
        ::= { nwAppnSysCfgLocalNode 1 }

nwAppnSysCpAlias   OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies the Control Point alias name used by APPN Routing
                Services. "
        ::= { nwAppnSysCfgLocalNode 2 }

nwAppnSysModeCosMap   OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies whether mode to COS mapping is supported by
                APPN Routing Services."
        DEFVAL { yes }
        ::= { nwAppnSysCfgLocalNode 3 }

nwAppnSysMdsSupport   OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies whether Management Services supports Multiple
                Domain Support and Management Services capabilities. "
        DEFVAL { yes }
        ::= { nwAppnSysCfgLocalNode 4 }

nwAppnSysMaxLocates   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum Number of locate requests that APPN Routing
                Services can concurrently process. Note: if nwAppnSysMaxLocates is
                set to a value too small, it will be internally increased to a
                higher value after APPN Routing Services has been successfully
                enabled. A subsequent GET operation on nwAppnSysMaxLocates will
                reflect this new value."
        DEFVAL { 10 }
        ::= { nwAppnSysCfgLocalNode 6 }

nwAppnSysDirCacheSize   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies number of located resources maintained in the Directory
                Cache.  Note: if nwAppnSysDirCacheSize is set to a value too small,
                it will be internally increased to a higher value after APPN routing
                services has been successfully enabled. A subsequent GET
                operation on nwAppnSysDirCacheSize will reflect this new value. "
        DEFVAL { 255 }
        ::= { nwAppnSysCfgLocalNode 7 }

nwAppnSysMaxDirEntries   OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum number of directory entries.  If zero is selected,
                the number of entries is unlimited. "
        DEFVAL { 0 }
        ::= { nwAppnSysCfgLocalNode 8}

nwAppnSysLocateTimeout   OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies time in seconds before a network search will timeout. Zero
                indicates that the search has no timeout."
        DEFVAL { 0 }
        ::= { nwAppnSysCfgLocalNode 9 }

nwAppnSysRegCds   OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies whether the local or domain resources can be registered
                with the Central Directory Server."
        DEFVAL { yes }
        ::= { nwAppnSysCfgLocalNode 10 }

nwAppnSysMdsSendQSize   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies size of the MDS send alert Queue."
        DEFVAL { 100 }
        ::= { nwAppnSysCfgLocalNode 11 }

nwAppnSysCosSize   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum number of COS definitions maintained in the COS
                database weights cache. It determines the size of the COS Database
                weights cache.  Note: if nwAppnSysCosSize is set to a value too
                small, it will be internally increased to a higher value after
                APPN Routing Services has been successfully enabled. A subsequent
                GET operation on nwAppnSysCosSize will reflect this new value. "
        DEFVAL { 16 }
        ::= { nwAppnSysCfgLocalNode 12 }

nwAppnSysTreeSize   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies the number of routes maintained in the Topology Database
                routing tree cache. Note: if nwAppnSysTreeSize is set to a value
                too small, it will be internally increased to a higher value after
                APPN Routing Services has been successfully enabled. A subsequent
                GET operation on nwAppnSysTreeSize will reflect this new value. "
        DEFVAL { 40 }
        ::= { nwAppnSysCfgLocalNode 13 }

nwAppnSysTreeUseLimit   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Maximum number of times a cached tree will be used to compute a
                route before the tree is discarded and recomputed.  This
                allows the APPN Routing Services to balance sessions among
                equal weight routes. A low value provides better load balancing
                at the expense of increased activation latency. "
        DEFVAL { 40 }
        ::= { nwAppnSysCfgLocalNode 14 }

nwAppnSysMaxTdmNodes   OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum number of nodes that can be stored in the Topology
                Database. Zero means unlimited. "
        DEFVAL { 0 }
        ::= { nwAppnSysCfgLocalNode 15 }

nwAppnSysMaxTdmTGs   OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum number of transmission groups that can be stored in
                Topology Database. Zero means unlimited. "
        DEFVAL { 0 }
        ::= { nwAppnSysCfgLocalNode 16 }

nwAppnSysMaxIsrSessions   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum number of intermediate routing sessions permitted
                by APPN Routing Services at one time. This must be a non-negative
                number."
        DEFVAL { 1000 }
        ::= { nwAppnSysCfgLocalNode 18 }

nwAppnSysIsrUpperThresh   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "The thresholds control the congestion status of APPN routing
                services.  If the number of ISR sessions exceeds the upper
                threshold, congestion status changes from uncongested to congested.
                When this occurs, the status will not become uncongested until the
                the number of ISR sessions fall below the lower threshold. The
                lower threshold should be less than the upper threshold to prevent
                thrashing. The upper threshold should be lower than
                nwAppnSysMaxIsrSessions.  This must be a non-negative number."
        DEFVAL { 900 }
        ::= { nwAppnSysCfgLocalNode 19 }

nwAppnSysIsrLowerThresh   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifes the number of ISR sessions at which congestion status will
                revert to uncongested. This must be a non-negative number.
                nwAppnSysIsrLowerThresh must be less than nwAppnSysIsrUpperThresh
                to prevent thrashing. "
        DEFVAL { 800 }
        ::= { nwAppnSysCfgLocalNode 20 }

nwAppnSysIsrMaxRuSize   OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies maximum RU size supported for intermediate sessions.
                Note: the number provided will be rounded up to the 
                next valid RU size if necessary after APPN Routing Services has
                been successfully enabled. A subsequent GET operation on
                nwAppnSysMaxLocates will reflect this new value."
        DEFVAL { 1024 }
        ::= { nwAppnSysCfgLocalNode 21 }

nwAppnSysIsrRcvPaceWind   OBJECT-TYPE
        SYNTAX  INTEGER (1..63)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies suggested receive pacing window size for intermediate
                sessions. This value may be used as a fixed window size for 
                fixed pacing, or as a tuning value for adaptive pacing. "
        DEFVAL { 8 }
        ::= { nwAppnSysCfgLocalNode 22 }

nwAppnSysRtAddResist   OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies a desirability factor for APPN Routing Services to
                perform intermediate session routing.  255 is least desirable
                and 0 is more desirable. "
        DEFVAL { 0 }
        ::= { nwAppnSysCfgLocalNode 23 }

nwAppnSysStopType   OBJECT-TYPE
        SYNTAX  INTEGER {
                  abort(1),      --  Shutdown APPN Routing Services immediately 
                  immediate(2),  --  deactivate links then abort(1)
                  quiesce(3),    --  advertize quiesce, deactivate endpoint
                                 --  sessions, then immediate(2)
                  quiesceIsr(4)  --  allow all isr sessions to end then
                                 --  quiesce(3)
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "Specifies the type of APPN Routing Services shutdown.
                Once specified, select disable from nwAppnSysAdminStatus. The
                shutdown choices are as follows:

                abort(1)       All APPN Routing Services components are immediately
                               stopped and resources released. To become active again,
                               the APPN Routing Services must be enabled.
                immediate(2)   APPN Routing Services immediately deactivates all links
                               then performs abort(1) processing.
                quiesce(3)     APPN Routing Services indicates to other APPN network
                               nodes that it is quiesced. Session limits
                               are reset on all modes, UNBINDs are issued
                               on all endpoint sessions (CP-CP sessions last),
                               and then immediate(2) processing is performed.
                quiesceIsr(4)  Allows all intermediate sessions to end,
                               then performs the quiesce(3) processing."
        DEFVAL { quiesceIsr }
        ::= { nwAppnSysCfgLocalNode 24 }

nwAppnSysBlockNum       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(3))
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This represents the 3 hexadecimal digit block number which 
                precedes the 5 digit id number in the 8 digit node id used in
                XIDs and Alerts. The block number identifies the product type.
                Both the block number and id number combined, uniquely identify
                this instance of APPN Routing Services within the installation
                network."
--      DEFVAL { 'e08'H }
        ::= { nwAppnSysCfgLocalNode 25 }

nwAppnSysIdNum          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(5))
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This represents the 5 hexadecimal digit id number which follows
                the 3 digit block number in the 8 digit node id used in XIDs and
                Alerts. The id number uniquely identifies this instance of APPN
                Routing Services within a product type indicated by the block number.
                Both the block number and id number combined, uniquely identify
                this instance of APPN Routing Services within the installation
                network."
--      DEFVAL { '00000'H }
        ::= { nwAppnSysCfgLocalNode 26 }


--  APPN Router System Group - Local APPN Routing Service Parameters
--  This group contains tables related to configuring:
--
--      LU Definition Table


--  
--  LU Table
--  


nwAppnSysLuTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwAppnSysLuEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains entries for LUs that are owned by adjacent
                 LEN nodes. Defining or deleting an entry is equivalent to defining
                 or deleting an entry in the directory database. To add an entry,
                 set nwAppnSysLuControl to other. To delete an entry, set
                 nwAppnSysLuControl to delete."
                ::= { nwAppnSysCfgTables 1 }

nwAppnSysLuEntry OBJECT-TYPE
        SYNTAX  NwAppnSysLuEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Each entry defines an LU entry in the directory database. The
                fully qualified CP name and the name of the LU are the indexes into
                this table."
        INDEX   { nwAppnSysCpName, nwAppnSysLuName }
        ::= { nwAppnSysLuTable 1 }

NwAppnSysLuEntry ::= SEQUENCE {
        nwAppnSysCpName         DisplayString,
        nwAppnSysLuName         DisplayString,
        nwAppnSysLuControl      INTEGER
                                   }

nwAppnSysCpName OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (3..17))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the fully qualified name of the Control Point 
                containing the LU being defined. The format of this name
                is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and
                CCCCCCCC is the LU or Control Point name. Valid characters to make
                up these two strings are uppercase letters A through Z, numerics 0
                through 9 and the special charcters $, @, and #.  The first character
                of the name must NOT be numeric. Each string must be a maximum length
                of 8 characters with no embedded spaces and the strings are joined by
                a dot.  This CP name must appear as an Adjacent CP in a link station
                definition where the adjacent CP type is EN and CP-CP session support
                is NO."
        ::= { nwAppnSysLuEntry 1 }

nwAppnSysLuName OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the name of the LU being registered. The name format is
                LLLLLLLL where LLLLLLLL are the characters: uppercase letters
                A through Z, numerics 0 through 9, and the special characters
                $, @, and #. The first character of the name must NOT be numeric.
                The string must be a maximum length of 8 characters with no
                embedded spaces. Note that the nework identifier of the LU is 
                taken from the fully qualified control point name of the adjacent
                LEN node (nwAppnSysCpName) which owns the LU. "
        ::= { nwAppnSysLuEntry 2 }

nwAppnSysLuControl  OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),
                        delete(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Set this object to delete to remove an entry."
        ::= { nwAppnSysLuEntry 3 }



--  APPN System Administration Group
--  This group contains the objects that pertain to the administration of
--  APPN Routing Services at a global, system-wide level.

nwAppnSysAdminStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                  other(1),             --  none of the following
                  disable(2),           --  shut down APPN Routing Services 
                  enabled(3)            --  start up APPN Routing Services
                        
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Sets the system-wide administrative state of APPN Routing Services.
                If enable(3) is selected, APPN Routing Services is activated.

                There are two cases: the very first activation, and activations
                subsequent to the successful first activation. Before activating
                APPN Routing Services the very first time, nwAppnSysRouterId in
                the System Configuration branch and all objects under
                nwAppnSysCfgLocalNode must be assigned a value. If not explicitly
                assigned, default values will be used for objects under
                nwAppnSysCfgLocalNode. After this first activation has completed
                successfully, all objects under nwAppnSysCfgLocalNode will be
                saved in non-volatile RAM and restored for the next node activation
                at power up time. After this subsequent power up, enable(3) may be
                selected without setting nwAppnSysRouterId or any objects under
                under nwAppnSysCfgLocalNode. Those values defined prior to the
                last power up or reset will be used.

                If disable(2) is selected, APPN Routing Services will become
                inactive in the manner specifed by nwAppnSysStopType. To
                modify objects under nwAppnSysCfgLocalNode, nwAppnSysAdminStatus
                must be disabled. "

        ::= { nwAppnSysAdministration 1 }

nwAppnSysOperStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  inactive
                        enabled(3),           --  active
                        pendingDisable(4),    --  deactivate in progress
                        pendingEnable(5)      --  activate in progress
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the current operating system-wide status of APPN 
                Routing Services.  "
        ::= { nwAppnSysAdministration 2 }

nwAppnSysAdminReset      OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Resets APPN Routing Services system-wide. Reset (2) forces a
                restart of APPN Routing Services without a graceful shutdown on
                any active router ports, without affecting any other routing
                services."
        ::= { nwAppnSysAdministration 3 }

nwAppnSysOperationalTime  OBJECT-TYPE
        SYNTAX  TimeTicks 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the elapsed time, in hundredths of a second, that
                nwAppnOperStatus has been in its current state."
        ::= { nwAppnSysAdministration 4 }

nwAppnSysVersion  OBJECT-TYPE
        SYNTAX  DisplayString 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the current revision level of APPN routing 
                 services in textual format."
        ::= { nwAppnSysAdministration 5 }


--  APPN Forwarding Group
--  This group contains the managed objects used to setup and configure
--  APPN Routing Services for aggregate, system-wide, port Message Unit
--  (MU) and byte counters.


nwAppnFwdCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the administrative state of the aggregate, system-wide,
                port Message Unit (MU) and byte counters. Enabled (3) causes
                these counters to become active.  Disabled (2) causes these
                counters to become inactive."
        ::= { nwAppnFwdCounters 1 }

nwAppnFwdCtrReset        OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Resets the aggregate, system-wide port Message Unit (MU)
                and byte counters. Reset (2) resets the aggregate counters to 0.
                nwAppnFwdCtrOperationalTime is also reset to 0."
        ::= { nwAppnFwdCounters 2 }

nwAppnFwdCtrOperationalTime       OBJECT-TYPE
        SYNTAX          TimeTicks
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the elapsed time, in hundredths of a second,
                that nwAppnFwdCtrAdminStatus has been in the current state."
        ::= { nwAppnFwdCounters 3 }

nwAppnFwdCtrInMus       OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have
                been received system-wide (for all ports) during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 4 }

nwAppnFwdCtrOutMus      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have
                been transmitted system-wide (for all ports) during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 5 }

nwAppnFwdCtrFwdMus      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have
                been forwarded system-wide (for all ports) during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 6 }

nwAppnFwdCtrFilteredMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 7 }

nwAppnFwdCtrDiscardMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 8 }

nwAppnFwdCtrAddrErrMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs)
                that have been received system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime, that contain an address error(s)
                in the SNA header."
        ::= { nwAppnFwdCounters 9 }

nwAppnFwdCtrLenErrMus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been received system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime, that contain a length error."
        ::= { nwAppnFwdCounters 10 }

nwAppnFwdCtrHdrErrMus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been received system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime, that contain an SNA header error
                other than an address or length error."
        ::= { nwAppnFwdCounters 11 }

nwAppnFwdCtrInBytes     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates number of bytes in Message Units (MUs) that have
                been received system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 12 }

nwAppnFwdCtrOutBytes    OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs) that
                have been forwarded system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 13 }

nwAppnFwdCtrFwdBytes    OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs) that
                have been forwarded system-wide (for all ports), during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 14 }

nwAppnFwdCtrFilteredBytes        OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 15 }

nwAppnFwdCtrDiscardBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 16 }

nwAppnFwdCtrHostInMus   OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been delivered system-wide (for all ports), to local half
                sessions during nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 17 }

nwAppnFwdCtrHostOutMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been successfully sent from local half sessions system-wide
                (for all ports), to Path Control during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 18 }

nwAppnFwdCtrHostDiscardMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 19 }


nwAppnFwdCtrHostInBytes  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs)
                that have been delivered system-wide (for all ports), to
                local half sessions during nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 20 }

nwAppnFwdCtrHostOutBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs)
                that have been successfully sent from local half sessions
                system-wide (for all ports), to Path Control during
                nwAppnFwdCtrOperationalTime."
        ::= { nwAppnFwdCounters 21 }

nwAppnFwdCtrHostDiscardBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdCounters 22 }


--  APPN Forwarding Port Table
--  This table contains the managed objects used to setup and configure
--  each port used by APPN Routing Services.
--
--
nwAppnFwdIfTable        OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwAppnFwdIfEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "This table contains an entry for each router port which can
                be used by APPN Routing Services. This table is indexed by
                nwAppnFwdIfIndex, which indicates the value of MIB 2 ifindex
                which identifes the router port for which an entry exists.
                These port configuration entries will be provided automatically
                based on physical port configuration. Such entries cannot be
                deleted - only modified."
        ::= { nwAppnFwdIfConfig 1 }

nwAppnFwdIfEntry    OBJECT-TYPE
        SYNTAX          NwAppnFwdIfEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "Each entry specifies the APPN Routing Services port
                configuration for the router port for which the entry exists."
        INDEX   { nwAppnFwdIfIndex }
        ::= { nwAppnFwdIfTable 1 }

NwAppnFwdIfEntry ::=
        SEQUENCE {
                nwAppnFwdIfIndex                INTEGER,
                nwAppnFwdIfAdminStatus          INTEGER,
                nwAppnFwdIfOperStatus           INTEGER,
                nwAppnFwdIfOperationalTime      TimeTicks,
                nwAppnFwdIfControl              INTEGER,
                nwAppnFwdIfMtu                  INTEGER,
                nwAppnFwdIfForwarding           INTEGER,
                nwAppnFwdIfFrameType            INTEGER,
                nwAppnFwdIfAclIdentifier        INTEGER,
                nwAppnFwdIfAclStatus            INTEGER,
                nwAppnFwdIfCacheControl         INTEGER,
                nwAppnFwdIfCacheEntries         Counter,
                nwAppnFwdIfCacheHits            Counter,
                nwAppnFwdIfCacheMisses          Counter
        }

nwAppnFwdIfIndex        OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the value of MIB2 ifindex, which identifies the
                router port for which the entry exists. "
        ::= { nwAppnFwdIfEntry 1 }

nwAppnFwdIfAdminStatus      OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disable(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the administrative state of an APPN Routing Services 
                port for which the entry exists. enabled(3) causes the
                APPN Routing Services port to become active. disable(2)
                causes it to become inactive. There are various choices
                for the method by which the port can be disabled, which are
                enumerated by nwAppnExtIfStopType. "
    ::= { nwAppnFwdIfEntry 2 }

nwAppnFwdIfOperStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  inactive
                        enabled(3),           --  active
                        pendingDisable(4),    --  deactivate in progress
                        pendingEnable(5)      --  activate in progress
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
               "Indicates the current operating condition of the APPN Routing
                Services port for which the entry exists."
        ::= { nwAppnFwdIfEntry 3 }

nwAppnFwdIfOperationalTime   OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the elapsed time, in hundredths of a second, that
                nwAppnFwdIfOperStatus has been in the current state."
        ::= { nwAppnFwdIfEntry 4 }

nwAppnFwdIfControl  OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 5 }

nwAppnFwdIfMtu      OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 6 }

nwAppnFwdIfForwarding       OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 7 }

nwAppnFwdIfFrameType        OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            ethernet(2),
                            i8022(4),
                            sync(8)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
               "Specifies the framing type for the APPN Routing Services port
                for which the entry exists. "
        ::= { nwAppnFwdIfEntry 8 }

nwAppnFwdIfAclIdentifier    OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 9 }

nwAppnFwdIfAclStatus        OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 10 }

nwAppnFwdIfCacheControl     OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                disable(2),
                                enable(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 11 }

nwAppnFwdIfCacheEntries     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 12 }

nwAppnFwdIfCacheHits        OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 13 }

nwAppnFwdIfCacheMisses      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs. Setting this object has no effect."
        ::= { nwAppnFwdIfEntry 14 }


--  The APPN Routing Services Port Extension Table
--  This table contains additional objects used to setup and configure
--  APPN Routing Services on a per port basis.

nwAppnExtensionTable    OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwAppnExtEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains additional APPN definitions for each
                physical port. Entries cannot be added to or deleted from this
                table. With the exception of nwAppnExtIfStopType, objects in
                this table may only be modified when nwAppnFwdIfAdminStatus
                is disabled.  Note: if APPN Routing Services is not active, no
                entries will exist for this table. "
        ::= { nwAppnFwdIfConfig 2 }

nwAppnExtEntry    OBJECT-TYPE
        SYNTAX  NwAppnExtEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Each entry specifies additional APPN configuration parameters
                for the port for which this entry exists."
        INDEX   { nwAppnExtIfIndex }
        ::= { nwAppnExtensionTable 1 }

NwAppnExtEntry ::=
        SEQUENCE {
                nwAppnExtIfIndex                INTEGER,
                nwAppnExtIfPortName             DisplayString,
                nwAppnExtIfPortType             INTEGER,
                nwAppnExtIfDlcType              INTEGER,
                nwAppnExtIfMaxRBtuSize          INTEGER,
                nwAppnExtIfTotLsActLim          INTEGER,
                nwAppnExtIfInbLsActLim          INTEGER,
                nwAppnExtIfOutbLsActLim         INTEGER,
                nwAppnExtIfLocalLsRole          INTEGER,
                nwAppnExtIfActXidXchgLimit      INTEGER,
                nwAppnExtIfNonActXidXchgLimit   INTEGER,
                nwAppnExtIfLsXmitRcvCap         INTEGER,
                nwAppnExtIfMaxIfrmRcvd          INTEGER,
                nwAppnExtIfDfltTargetPacing     INTEGER,
                nwAppnExtIfDfltMaxSBtuSize      INTEGER,
                nwAppnExtIfDfltEffectCap        INTEGER,
                nwAppnExtIfDfltConnectCost      INTEGER,
                nwAppnExtIfDfltByteCost         INTEGER,
                nwAppnExtIfDfltSecurity         INTEGER,
                nwAppnExtIfDfltPropDelay        INTEGER,
                nwAppnExtIfDfltUsrDef1          INTEGER,
                nwAppnExtIfDfltUsrDef2          INTEGER,
                nwAppnExtIfDfltUsrDef3          INTEGER,
                nwAppnExtIfStopType             INTEGER,
                nwAppnExtIfCpCpSupp             INTEGER,
                nwAppnExtIfLimitedRsrc          INTEGER,
                nwAppnExtIfAddress              OCTET STRING,
                nwAppnExtIfSsap                 OCTET STRING
        }

nwAppnExtIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the primary index into the APPN port extension table.
                This number corresponds to the index into the nwAppnFwdIfTable. "
        ::= { nwAppnExtEntry 1 }

nwAppnExtIfPortName  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..8))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the user friendly name for this port. "
        ::= { nwAppnExtEntry 2 }

nwAppnExtIfPortType  OBJECT-TYPE
        SYNTAX  INTEGER {
                        nonswitched(1),
                        switched(2),
                        satf(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the type of line used by the port.  The value
                 corresponds to one of the following:  nonswitched(1),
                 switched(2), or satf(3). "
        ::= { nwAppnExtEntry 4 }

nwAppnExtIfDlcType  OBJECT-TYPE
        SYNTAX  INTEGER {
                        llc2(1),
                        sdlc(2),
                        x25(3)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the type of DLC using the port. "
        ::= { nwAppnExtEntry 5 }

nwAppnExtIfMaxRBtuSize  OBJECT-TYPE
        SYNTAX  INTEGER (99..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the maximum Message Unit (MU) size that can be received. "
        DEFVAL { 2048 }
        ::= { nwAppnExtEntry 6 }

nwAppnExtIfTotLsActLim  OBJECT-TYPE
        SYNTAX  INTEGER (1..256)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of links that can be active on this
                port. If nwAppnExtIfPortType = nonswitched(1) and
                nwAppnExtIfLocalLsRole = negotiable(1), or secondary(3), then
                this value must be set to 1. "
        DEFVAL { 16 }
        ::= { nwAppnExtEntry 7 }

nwAppnExtIfInbLsActLim  OBJECT-TYPE
        SYNTAX  INTEGER (0..256)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of inbound links that can be active on
                this port.  If nwAppnExtIfPortType = nonswitched(1) and
                nwAppnExtIfLocalLsRole = negotiable(1) or primary(2), then this
                value must be set to 0. "
        DEFVAL { 8 }
        ::= { nwAppnExtEntry 8 }

nwAppnExtIfOutbLsActLim  OBJECT-TYPE
        SYNTAX  INTEGER (0..256)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of outbound links that can be active on
                this port.  If nwAppnExtIfPortType = nonswitched(1) and
                nwAppnExtIfLocalLsRole = negotiable(1), then this value must be
                set to 0.  If nwAppnExtIfLocalLsRole = primary(2), then this value
                must be set the same as nwAppnExtIfTotLsActLim. "
        DEFVAL { 8 }
        ::= { nwAppnExtEntry 9 }

nwAppnExtIfLocalLsRole  OBJECT-TYPE
        SYNTAX  INTEGER  {  negotiable(1),
                            primary(2),
                            secondary(3)  }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the link station role - primary, secondary, or
                negotiable.  For nwAppnExtIfPortType = satf(3), the link station
                role must be negotiable(1). "
        DEFVAL { negotiable }
        ::= { nwAppnExtEntry 10 }

nwAppnExtIfActXidXchgLimit  OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of activation XIDs that may be
                exchanged. "
        DEFVAL { 9 }
        ::= { nwAppnExtEntry 11 }

nwAppnExtIfNonActXidXchgLimit  OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of non-activation XIDs that may be
                exchanged. "
        DEFVAL { 5 }
        ::= { nwAppnExtEntry 12 }

nwAppnExtIfLsXmitRcvCap  OBJECT-TYPE
        SYNTAX  INTEGER  { twowaysimultaneous(1), 
                           twowayalternating(2)  }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the link station's transmit/receive capability. "
        DEFVAL { twowaysimultaneous }
        ::= { nwAppnExtEntry 13 }

nwAppnExtIfMaxIfrmRcvd  OBJECT-TYPE
        SYNTAX  INTEGER (1..127)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the maximum number of I-frames received before an
                acknowledgment is sent to the sender. "
        DEFVAL { 4 }
        ::= { nwAppnExtEntry 14 }

nwAppnExtIfDfltTargetPacing  OBJECT-TYPE
        SYNTAX  INTEGER (1..32767) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the pacing window size for BINDs on this transmission
                group. "
        DEFVAL { 7 }
        ::= { nwAppnExtEntry 15 }

nwAppnExtIfDfltMaxSBtuSize  OBJECT-TYPE
        SYNTAX  INTEGER (99..65535) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the maximum Message Unit (MU) size which can be sent. "
        DEFVAL { 2048 }
        ::= { nwAppnExtEntry 16 }

nwAppnExtIfDfltEffectCap  OBJECT-TYPE
        SYNTAX  INTEGER  (0..603979776)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the default maximum kilo bits per second rate
                (line speed) for all links on this port. "
        ::= { nwAppnExtEntry 17 }

nwAppnExtIfDfltConnectCost  OBJECT-TYPE
        SYNTAX  INTEGER (0..255) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the default cost per connect time for all link
                stations on this port.  0 is the lowest cost and 255 is the
                largest cost. "
        ::= { nwAppnExtEntry 18 }

nwAppnExtIfDfltByteCost  OBJECT-TYPE
        SYNTAX  INTEGER (0..255) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the default Cost per Byte for link stations. 0 is
                the lowest cost and 255 is the largest cost. "
        ::= { nwAppnExtEntry 19 }

nwAppnExtIfDfltSecurity  OBJECT-TYPE
        SYNTAX  INTEGER {       nonsecure(1),           --X'01'
                                publicSwitchNw(32),     --X'20'
                                undergroundCable(64),   --X'40'
                                secureConduit(96),      --X'60'
                                guardedConduit(128),    --X'80'
                                encrypted(160),         --X'A0'
                                guardedRadiation(192)   --X'C0'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specify one of the following security selections:

                        non-secure        - specifies no security.
                        public switched   - data flows over a public switched 
                                            network.
                        underground cable - data transmitted over a secure
                                            underground cable.
                        secure conduit    - line is secure conduit that is not
                                            guarded.
                        guarded conduit   - conduit that is protected against
                                            physical tapping.
                        encrypted         - encryption over the line.
                        guarded radiation - line is proected against physical
                                            and radiation tapping. "

        ::= { nwAppnExtEntry 20 }

nwAppnExtIfDfltPropDelay  OBJECT-TYPE
        SYNTAX  INTEGER {       
                                minimum(0),                     --X'00'
                                negligible(384),                --X'4C'
                                terrestrial(9216),              --X'71'
                                packetswitched(147456),         --X'91'
                                long(294912),                   --X'99'
                                maximum(2013265920)             --X'FF'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the propagation delay which represents the relative
                time it takes for a signal to travel the length of the link in
                microseconds, with some of the more common default values
                enumerated. The default times in parentheses are in microseconds.
                These default values fall into the following ranges:

                        minimum                 - no propagation delay
                        negligible, lan         - less than 480 microseconds
                        terrestrial, telephone  - between 480 and 49,512
                                                  microseconds
                        packetswitched          - between 49,512 and 245,760
                                                  microseconds
                        long, satellite         - more than 245760 microseconds.
                        maximum                 - the maximum propagation delay. "
        ::= { nwAppnExtEntry 21 }

nwAppnExtIfDfltUsrDef1  OBJECT-TYPE
        SYNTAX  INTEGER (0..255) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 1. "
        DEFVAL { 128 }
        ::= { nwAppnExtEntry 22 }

nwAppnExtIfDfltUsrDef2  OBJECT-TYPE
        SYNTAX  INTEGER (0..255) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 2. "
        DEFVAL { 128 }
        ::= { nwAppnExtEntry 23 }

nwAppnExtIfDfltUsrDef3  OBJECT-TYPE
        SYNTAX  INTEGER (0..255) 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 3. "
        DEFVAL { 128 }
        ::= { nwAppnExtEntry 24 }

nwAppnExtIfStopType OBJECT-TYPE
        SYNTAX  INTEGER { 
                  immediate(1), 
                  orderly(2) 
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the type of shutdown for APPN Routing Services
                on the port. Once set, nwAppnFwdIfAdminStatus may
                be set to disable. The disable choices are as follows:

                   immediate(1) causes the link stations belonging to the
                                physical port to be disabled immediately
                                without flushing pending messages and 
                                without initiating an orderly disconnect sequence.
                   orderly(2)   causes pending messages in link stations to be
                                flushed, followed by an orderly disconnect
                                sequence.  The link station is then disabled. "
        DEFVAL { orderly }
        ::= { nwAppnExtEntry 25 }

nwAppnExtIfCpCpSupp  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether CP-CP sessions are permitted on dynamic 
                 links generated on this port. "
        DEFVAL { yes }
        ::= { nwAppnExtEntry 26 }

nwAppnExtIfLimitedRsrc  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether dynamic links generated on this port
                are a limited resource. A limited resource link will
                be deactivated when there are no sessions using the link."
        DEFVAL { no }
        ::= { nwAppnExtEntry 27 }

nwAppnExtIfAddress  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (1..32))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the physical address of this port depending on the
                media type. For token ring or ethernet ports, the information is
                the 6 byte MAC address which starts in byte 1 and ends in byte 6.
                For token ring ports the MAC address must be specified in non-
                canonical format. For ethernet ports the MAC address must be 
                specified in canonical format.  For frame relay ports, there is
                no associated address, i.e., it will be a zero length octet string."
        ::= { nwAppnExtEntry 28 }

nwAppnExtIfSsap  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (1))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For token ring or ethernet ports specifies the Source SAP Address
                of this port. "
        DEFVAL { '04'h }
        ::= { nwAppnExtEntry 29 }


--
--  Connection Network Tables
--

nwAppnIfCnPortTable     OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwAppnIfCnPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains definitions for the Connection
                 Network port table which defines which local ports can
                 access a connection network. To add a row to the table,
                 nwAppnIfCnPtFqName and nwAppnIfCnPtName are required entries.
                 To delete a row, set the control field to delete.
                 Adding the first row for a connection network implicitly
                 creates the connection network and deleting the last
                 remaining row for a connection network implicitly removes
                 the connection network."
        ::= { nwAppnIfCn 1 }

nwAppnIfCnPortEntry    OBJECT-TYPE
        SYNTAX  NwAppnIfCnPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Specifies the APPN Connection Network port definitions."
        INDEX   { nwAppnIfCnPtFqName, nwAppnIfCnPtName }
        ::= { nwAppnIfCnPortTable 1 }

NwAppnIfCnPortEntry ::=
        SEQUENCE {
                nwAppnIfCnPtFqName             DisplayString,
                nwAppnIfCnPtName               DisplayString,
                nwAppnIfCnPtControl            INTEGER
        }

nwAppnIfCnPtFqName  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (3..17))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the fully-qualified Name of the Virtual Routing Node.
                The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the
                network identifier and CCCCCCCC is the Control Point name. Valid
                characters to make up these two strings are uppercase letters
                A through Z, numerics 0 through 9, and the special characters
                $, @, and #.  The first character of the name must NOT be
                numeric. Each string must be a maximum length of 8 characters
                with no embedded spaces and the strings are joined by a dot. "
        ::= { nwAppnIfCnPortEntry 1 }

nwAppnIfCnPtName     OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies one of the ports which can access this Connection
                Network."
        ::= { nwAppnIfCnPortEntry 2 }

nwAppnIfCnPtControl  OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),
                        delete(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Set this object to delete to delete this port from this
                Connection Network."
        ::= { nwAppnIfCnPortEntry 3 }


nwAppnIfCnTgCharTable     OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwAppnIfCnTgCharEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains the APPN definitions for a Connection
                Network's transmission group characteristics. Rows may be
                neither added nor deleted, only modified. Rows are
                added/deleted implicitly through CnPortTable."
        ::= { nwAppnIfCn 2 }


nwAppnIfCnTgCharEntry    OBJECT-TYPE
        SYNTAX  NwAppnIfCnTgCharEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Specifies the APPN transmission group characteristics for
                the Connection Network."
        INDEX   { nwAppnIfCnTgFqName }
        ::= { nwAppnIfCnTgCharTable 1 }

NwAppnIfCnTgCharEntry ::=
        SEQUENCE {
                nwAppnIfCnTgFqName                DisplayString,
                nwAppnIfCnTgEffectCap             INTEGER,
                nwAppnIfCnTgConnectCost           INTEGER,
                nwAppnIfCnTgByteCost              INTEGER,
                nwAppnIfCnTgSecurity              INTEGER,
                nwAppnIfCnTgPropDelay             INTEGER,
                nwAppnIfCnTgUsrDef1               INTEGER,
                nwAppnIfCnTgUsrDef2               INTEGER,
                nwAppnIfCnTgUsrDef3               INTEGER
        }

nwAppnIfCnTgFqName  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (3..17))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the fully-qualified Name of the Virtual Routing Node.
                The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the
                network identifier and CCCCCCCC is the Control Point name. Valid
                characters to make up these two strings are uppercase letters
                A through Z, numerics 0 through 9, and the special characters
                #, $, and @. The first character of the name must NOT be
                numeric. Each string must be a maximum length of 8 characters
                with no embedded spaces and the strings are joined by a dot. "
        ::= { nwAppnIfCnTgCharEntry 1 }

nwAppnIfCnTgEffectCap  OBJECT-TYPE
        SYNTAX  INTEGER (0..603979776)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the maximum kilo bits per second rate (link speed) for
                the connection network. "
        ::= { nwAppnIfCnTgCharEntry 2 }

nwAppnIfCnTgConnectCost  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the cost per connect time for the Connection Network.
                0 is the lowest cost and 255 is the largest cost."
        ::= { nwAppnIfCnTgCharEntry 3 }

nwAppnIfCnTgByteCost  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the cost per byte for the Connection Network.
                0 is the lowest cost and 255 is the largest cost."
        ::= { nwAppnIfCnTgCharEntry 4 }

nwAppnIfCnTgSecurity  OBJECT-TYPE
        SYNTAX  INTEGER {       nonsecure(1),           --X'01'
                                publicSwitchNw(32),   --X'20'
                                undergroundCable(64),  --X'40'
                                secureConduit(96),     --X'60'
                                guardedConduit(128),   --X'80'
                                encrypted(160),         --X'A0'
                                guardedRadiation(192)  --X'C0'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For the Connection Network, specify one of the following
                 security selections:
                        non-secure - specifies no security.
                        public switched - data flows over a public switched
                                network.
                        underground cable - data transmitted over a secure
                                underground cable.
                        secure conduit - line is secure conduit that is not
                                guarded.
                        guarded conduit - conduit that is protected against
                                physical tapping.
                        encrypted - encryption over the line.
                        guarded radiation - line is proected against physical
                                and radiation tapping. "
        ::= { nwAppnIfCnTgCharEntry 5 }

nwAppnIfCnTgPropDelay OBJECT-TYPE
        SYNTAX  INTEGER {       
                                minimum(0),                     --X'00'
                                negligible(384),                --X'4C'
                                terrestrial(9216),              --X'71'
                                packetswitched(147456),         --X'91'
                                long(294912),                   --X'99'
                                maximum(2013265920)             --X'FF'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the propagation delay which represents the time it
                takes for a signal to travel the length of the link in
                microseconds, with some of the more common default values
                enumerated.  The default times in parentheses are in microseconds.
                These default values fall into the following ranges:

                        minimum                 - no propagation delay
                        negligible, lan         - less than 480 microseconds
                        terrestrial, telephone  - between 480 and 49,512
                                                  microseconds
                        packetswitched          - between 49,512 and 245,760
                                                  microseconds
                        long, satellite         - more than 245760 microseconds.
                        maximum                 - the maximum propagation delay. "
        ::= { nwAppnIfCnTgCharEntry 6 }

nwAppnIfCnTgUsrDef1  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 1. "
        DEFVAL { 128 }
        ::= { nwAppnIfCnTgCharEntry 7 }

nwAppnIfCnTgUsrDef2  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 2. "
        DEFVAL { 128 }
        ::= { nwAppnIfCnTgCharEntry 8 }

nwAppnIfCnTgUsrDef3  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 3. "
        DEFVAL { 128 }
        ::= { nwAppnIfCnTgCharEntry 9 }


--  APPN Forwarding Ports Counter Table
--  This table contains the objects that specify the Message Unit (MU) and byte
--  counters for each port used by APPN Routing Services.
--
--
nwAppnFwdIfCtrTable         OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwAppnFwdIfCtrEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "This table contains the Message Unit (MU) and byte counters for
                each port configured and enabled for APPN Routing Services. "
        ::= { nwAppnFwdIfCounters 1 }

nwAppnFwdIfCtrEntry         OBJECT-TYPE
        SYNTAX          NwAppnFwdIfCtrEntry
         ACCESS         not-accessible
        STATUS          mandatory
        DESCRIPTION
                "Each entry indicates Message Units (MU) and byte counts on
                the router port for which this entry exists."
        INDEX           { nwAppnFwdIfCtrIfIndex }
        ::= { nwAppnFwdIfCtrTable 1 }

NwAppnFwdIfCtrEntry ::=
        SEQUENCE {
                nwAppnFwdIfCtrIfIndex               INTEGER,
                nwAppnFwdIfCtrAdminStatus           INTEGER,
                nwAppnFwdIfCtrReset                 INTEGER,
                nwAppnFwdIfCtrOperationalTime       TimeTicks,
                nwAppnFwdIfCtrInMus                 Counter,
                nwAppnFwdIfCtrOutMus                Counter,
                nwAppnFwdIfCtrFwdMus                Counter,
                nwAppnFwdIfCtrFilteredMus           Counter,
                nwAppnFwdIfCtrDiscardMus            Counter,
                nwAppnFwdIfCtrAddrErrMus            Counter,
                nwAppnFwdIfCtrLenErrMus             Counter,
                nwAppnFwdIfCtrHdrErrMus             Counter,
                nwAppnFwdIfCtrInBytes               Counter,
                nwAppnFwdIfCtrOutBytes              Counter,
                nwAppnFwdIfCtrFwdBytes              Counter,
                nwAppnFwdIfCtrFilteredBytes         Counter,
                nwAppnFwdIfCtrDiscardBytes          Counter,
                nwAppnFwdIfCtrHostInMus             Counter,
                nwAppnFwdIfCtrHostOutMus            Counter,
                nwAppnFwdIfCtrHostDiscardMus        Counter,
                nwAppnFwdIfCtrHostInBytes           Counter,
                nwAppnFwdIfCtrHostOutBytes          Counter,
                nwAppnFwdIfCtrHostDiscardBytes      Counter
        }

nwAppnFwdIfCtrIfIndex       OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the value of MIB 2 ifindex, which identifies the
                 router port for which the entry exists. This is the primary
                index into the APPN per-port counter table. "
        ::= { nwAppnFwdIfCtrEntry 1 }

nwAppnFwdIfCtrAdminStatus   OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the administrative state of the per-port Message Unit
                (MU) and byte counters on the router port for which the entry
                exists.  enabled(3) causes these counters to become active.
                disabled(2) causes these counters to become inactive."
        ::= { nwAppnFwdIfCtrEntry 2 }

nwAppnFwdIfCtrReset         OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Resets the per-port Message Unit (MU) and byte counters on the
                router port for which this entry exists. reset (2) resets the
                counters to 0.  nwAppnFwdIfCtrOperationalTime is also reset to 0."
        ::= { nwAppnFwdIfCtrEntry 3 }

nwAppnFwdIfCtrOperationalTime        OBJECT-TYPE
        SYNTAX          TimeTicks
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the amount of time in hundreths of a second that the
                per-port Message Unit (MU) and byte counters have been active on
                the APPN routing services port for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 4 }

nwAppnFwdIfCtrInMus        OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have been 
                received, during nwAppnFwdIfCtrOperationaltime on the router port
                for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 5 }

nwAppnFwdIfCtrOutMus       OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have been
                transmitted, during nwAppnFwdIfCtrOperationalTime, on the router
                port for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 6 }

nwAppnFwdIfCtrFwdMus       OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MU)s that have
                been forwarded during nwAppnFwdIfCtrOperationalTime on the router
                port for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 7 }

nwAppnFwdIfCtrFilteredMus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 8 }

nwAppnFwdIfCtrDiscardMus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 9 }

nwAppnFwdIfCtrAddrErrMus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that contain
                an address error in the SNA header that have been received
                during nwAppnFwdIfCtrOperationalTime on the router port for which
                this entry exists."
        ::= { nwAppnFwdIfCtrEntry 10 }

nwAppnFwdIfCtrLenErrMus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that contain
                a length error that have been received during
                nwAppnFwdIfCtrOperationalTime on the router port for which
                this entry exists."
        ::= { nwAppnFwdIfCtrEntry 11 }

nwAppnFwdIfCtrHdrErrMus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that contain
                a header error other than an address or length error that have
                been received during nwAppnFwdIfCtrOperationalTime on the router
                port for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 12 }

nwAppnFwdIfCtrInBytes      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
               "Indicates the total number of bytes in the Message Units (MU)s
                that have been received, during nwAppnFwdIfCtrOperationalTime,
                on the router port for which the entry exists."
        ::= { nwAppnFwdIfCtrEntry 13 }

nwAppnFwdIfCtrOutBytes     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in the Message Units (MU)s
                that have been transmitted, during nwAppnFwdIfCtrOperationalTime,
                on the router port for which the entry exists."
        ::= { nwAppnFwdIfCtrEntry 14 }

nwAppnFwdIfCtrFwdBytes     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MU)s that
                have been forwarded during nwAppnFwdIfCtrOperationalTime on the
                router port for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 15 }

nwAppnFwdIfCtrFilteredBytes        OBJECT-TYPE
        SYNTAX                  Counter
        ACCESS                  read-only
        STATUS                  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 16 }

nwAppnFwdIfCtrDiscardBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 17 }

nwAppnFwdIfCtrHostInMus   OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been delivered to local half sessions during
                nwAppnFwdIfCtrOperationalTime on the router port for which this
                entry exists."
        ::= { nwAppnFwdIfCtrEntry 18 }

nwAppnFwdIfCtrHostOutMus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of Message Units (MUs) that have
                been successfully sent from local half sessions to Path Control
                during nwAppnFwdIfCtrOperationalTime on the router port for
                which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 19 }

nwAppnFwdIfCtrHostDiscardMus      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 20 }

nwAppnFwdIfCtrHostInBytes  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs)
                that have been delivered to local half sessions during
                nwAppnFwdIfCtrOperationalTime on the router port for which this
                entry exists."
        ::= { nwAppnFwdIfCtrEntry 21 }

nwAppnFwdIfCtrHostOutBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Indicates the total number of bytes in Message Units (MUs) that
                have been successfully sent from local half sessions to Path
                Control during nwAppnFwdIfCtrOperationalTime on the router port
                for which this entry exists."
        ::= { nwAppnFwdIfCtrEntry 22 }

nwAppnFwdIfCtrHostDiscardBytes     OBJECT-TYPE
        SYNTAX                  Counter
        ACCESS                  read-only
        STATUS                  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdIfCtrEntry 23 }



--  APPN Forwarding Adjacent Link Station Table
--  This table contains the managed objects used to set up and configure
--  links to adjacent link stations. Only those links that are configured by the
--  user can be modified. Links which are active cannot be modified.
--  If an attempt is made to modify an active link, the operational status
--  will indicate busy-failed.

nwAppnFwdLsTable     OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwAppnFwdLsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains the configuration and management 
                information for links to adjacent link stations. This table is
                indexed by nwAppnFwdLsName.  Operations which apply are add,
                delete, modify, enable, and disable.  To add a row to the
                table, the required fields in the row must be provided.
                The required fields are nwAppnFwdLsPortName and 
                nwAppnFwdLsDestAddr.  All other fields which are not provided
                will be defaulted.  To enable a link select enable(3) from
                nwAppnFwdLsAdminStatus. To delete a row, set nwAppnFwdLsControl
                to delete(3).  To disable a link set nwAppnFwdLsStopType and
                then select disable(2) in nwAppnFwdLsAdminStatus.
                If nwAppnFwdLsStopType is not selected, the link is disabled in
                an orderly fashion. "
        ::= { nwAppnFwdLsConfig 1 }

nwAppnFwdLsEntry    OBJECT-TYPE
        SYNTAX  NwAppnFwdLsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Specifies the configuration for a link to an adjacent link
                station for which the entry exists."
        INDEX   { nwAppnFwdLsName }
        ::= { nwAppnFwdLsTable 1 }

NwAppnFwdLsEntry ::=
        SEQUENCE {
                nwAppnFwdLsName                 DisplayString,
                nwAppnFwdLsAdminStatus          INTEGER,
                nwAppnFwdLsOperStatus           INTEGER,
                nwAppnFwdLsOperationalTime      TimeTicks,
                nwAppnFwdLsControl              INTEGER,
                nwAppnFwdLsPortName             DisplayString,
                nwAppnFwdLsAdjCpName            DisplayString,
                nwAppnFwdLsAdjCpType            INTEGER,
                nwAppnFwdLsAutoActSupport       INTEGER,
                nwAppnFwdLsLimitedRsrc          INTEGER,
                nwAppnFwdLsSscpSession          INTEGER,
                nwAppnFwdLsPuName               DisplayString,
                nwAppnFwdLsBackLvlLenEN         INTEGER,
                nwAppnFwdLsCpCpSessSupp         INTEGER,
                nwAppnFwdLsEffectCap            INTEGER,
                nwAppnFwdLsConnectCost          INTEGER,
                nwAppnFwdLsByteCost             INTEGER,
                nwAppnFwdLsSecurity             INTEGER,
                nwAppnFwdLsPropDelay            INTEGER,
                nwAppnFwdLsUsrDef1              INTEGER,
                nwAppnFwdLsUsrDef2              INTEGER,
                nwAppnFwdLsUsrDef3              INTEGER,
                nwAppnFwdLsTrgtPacingCount      INTEGER,
                nwAppnFwdLsMaxSendBtu           INTEGER,
                nwAppnFwdLsNumActiveSession     INTEGER,
                nwAppnFwdLsdynamicLs            INTEGER,
                nwAppnFwdLsStopType             INTEGER,
                nwAppnFwdLsPortNbr              INTEGER,
                nwAppnFwdLsDestAddr             OCTET STRING,
                nwAppnFwdLsDsap                 OCTET STRING,
                nwAppnFwdLsBlockNum             DisplayString,
                nwAppnFwdLsIdNum                DisplayString
        }

nwAppnFwdLsName    OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the primary index to the adjacent link station table
                (nwAppnFwdLsTable). "
        ::= { nwAppnFwdLsEntry 1 }

nwAppnFwdLsAdminStatus      OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disable(2),
                            enable(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the administrative state of a link to an adjacent
                link station. enabled(3) causes the link to become established.
                disable(2) causes the link to terminate. There are various
                severities of disabling a link which are selected via the leaf
                node nwAppnFwdLsStopType described further within this branch. "
    ::= { nwAppnFwdLsEntry 2 }

nwAppnFwdLsOperStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  inactive
                        enabled(3),           --  active
                        pendingDisable(4),    --  deactivate in progress
                        pendingEnable(5)      --  activate in progress
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the current operating status of the link for which this
                entry exists."
        ::= { nwAppnFwdLsEntry 3 }

nwAppnFwdLsOperationalTime   OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
               "Specifies the elapsed time, in hundredths of a second, that
                nwAppnFwdLsAdminStatus has been either enabled or DISABLED.
                If the operational state is pending-disable,
                nwAppnFwdLsOperationalTime indicates the amount of time since
                the state was enabled.  If the operational state is pending-enable,
                nwAppnFwdLsOperationalTime indicates the amount of time since the
                state was DISABLED."
        ::= { nwAppnFwdLsEntry 4 }

nwAppnFwdLsControl  OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),
                        delete(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Set this object to delete in order to delete the entry."
        ::= { nwAppnFwdLsEntry 5 }

nwAppnFwdLsPortName    OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This link station port name corresponds to the port name
                index into the the nwAppnExtensionTable which describes the
                router port on which the adjacent link station is defined."
        ::= { nwAppnFwdLsEntry 6 }

nwAppnFwdLsAdjCpName  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (3..17))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the fully-qualified, 17 byte long, adjacent Control
                Point name. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN
                is the network identifier and CCCCCCCC is the Control Point name.
                Valid characters to make up these two strings are uppercase
                letters A through Z, numerics 0 through 9, and the special
                characters $, # and @.  The first character of the name must NOT
                be numeric. Each string must be a maximum length of 8 characters
                with no embedded spaces and the strings are joined by a dot. "
        ::= { nwAppnFwdLsEntry 7 }

nwAppnFwdLsAdjCpType  OBJECT-TYPE
        SYNTAX  INTEGER { endnode(1), networknode(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the adjacent node type. The following values are
                valid: endnode(1), networknode(2). endnode(1) includes both
                End Node and LEN node types."
        DEFVAL { endnode }
        ::= { nwAppnFwdLsEntry 8 }

nwAppnFwdLsAutoActSupport  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether the link is automatically enabled when
                a session is activated over the link. It is an error to set
                this to yes(1) when nwAppnFwdLsCpCpSessSupp is set to yes(1). "
        DEFVAL { no }
        ::= { nwAppnFwdLsEntry 10 }

nwAppnFwdLsLimitedRsrc  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether this link is to be deactivated when
                there are no sessions using the link. If
                nwAppnFwdLsCpCpSessSupp is yes, however, the link will
                not be deactivated if CP-CP sessions are terminated.
                Note also that a link over a non-switched port cannot
                be configured as a limited resource."
        DEFVAL { no }
        ::= { nwAppnFwdLsEntry 11 }

nwAppnFwdLsSscpSession OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Requests a host system to initiate sessions between its SSCP and
                dependent LUs within APPN Routing Services. If set to yes,
                then nwAppnFwdLsPuName is required. Note: once this parameter
                is set along with other link station parameters associated with
                a link station definition, it cannot be modified. In order to
                change it, the link station definition itself must be deleted and
                then redefined with the new parameter."
        DEFVAL { no }
        ::= { nwAppnFwdLsEntry 12 }

nwAppnFwdLsPuName OBJECT-TYPE
SYNTAX  DisplayString (SIZE (1..8))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the name of the local PU if nwAppnFwdLsSscpSession is
                set to yes.  Valid characters are uppercase A through Z and
                numerics 0 through 9.  The name must start with an alphabetic
                character. Note: once this parameter is set along with other 
                link station parameters associated with a link station definition,
                it cannot be modified. In order to change it, the link station
                definition itself must be deleted and then redefined with the new
                parameter."
        ::= { nwAppnFwdLsEntry 13 }

nwAppnFwdLsBackLvlLenEN  OBJECT-TYPE
        SYNTAX  INTEGER { no(1), xid3(2), xid0(3), noxid(4) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether or not the adjacent node is a back level
                LEN Node. If so, specify the type of back level LEN node as
                follows:

                xid3(2) -       supports XID-3 protocols, but does not include 
                                Network Name control vector in the XID.

                xid0(3) -       Supports XID-0 protocols. Not valid if
                                nwAppnExtIfLocalLsRole is negotiable(1).

                noxid(4) -      Does not support XID protocols. Valid only if
                                nwAppnExtIfPortType is nonswitched(1) and not
                                valid if nwAppnExtIfLocalLsRole is negotiable(1).
                                
                If not no(1), then nwAppnFwdLsAdjCpName and nwAppnFwdLsIdNum
                must be specified. "
        DEFVAL { no }
        ::= { nwAppnFwdLsEntry 14 }

nwAppnFwdLsCpCpSessSupp  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether this link supports CP to CP sessions."
        DEFVAL { yes }
        ::= { nwAppnFwdLsEntry 16 }

nwAppnFwdLsEffectCap    OBJECT-TYPE
        SYNTAX  INTEGER (0..603979776)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies th maximum kilo bits per second rate (link speed)
                for the link. "
        ::= { nwAppnFwdLsEntry 17 }

nwAppnFwdLsConnectCost  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the cost per connect time for the link. Zero is the
                lowest cost and 255 is the largest cost."
        ::= { nwAppnFwdLsEntry 18 }

nwAppnFwdLsByteCost     OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the cost per Byte for the link. Zero is the lowest
                cost and 255 is the largest cost."
        ::= { nwAppnFwdLsEntry 19 }

nwAppnFwdLsSecurity     OBJECT-TYPE
        SYNTAX  INTEGER {       nonsecure(1),           --X'01'
                                publicSwitchNw(32),   --X'20'
                                undergroundCable(64),  --X'40'
                                secureConduit(96),     --X'60'
                                guardedConduit(128),   --X'80'
                                encrypted(160),         --X'A0'
                                guardedRadiation(192)  --X'C0'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Security selections available for the link are as follows:

                        non-secure        - specifies no security.
                        public switched   - data flows over a public switched
                                            network.
                        underground cable - data transmitted over a secure
                                            underground cable.
                        secure conduit    - line is secure conduit that is not
                                            guarded.
                        guarded conduit   - conduit that is protected against
                                            physical tapping.
                        encrypted         - encryption over the line.
                        guarded radiation - line is proected against physical
                                            and radiation tapping. "
        ::= { nwAppnFwdLsEntry 20 }

nwAppnFwdLsPropDelay    OBJECT-TYPE
        SYNTAX  INTEGER {       
                                minimum(0),                     --X'00'
                                negligible(384),                --X'4C'
                                terrestrial(9216),              --X'71'
                                packetswitched(147456),         --X'91'
                                long(294912),                   --X'99'
                                maximum(2013265920)             --X'FF'
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the propagation delay which represents the relative
                time it takes for a signal to travel the length of the link in
                microseconds, with some of the more common default values
                enumerated.  The default times in parentheses are in microseconds.
                These default values fall into the following ranges:

                        minimum                 - no propagation delay
                        negligible, lan         - less than 480 microseconds
                        terrestrial, telephone  - between 480 and 49,512
                                                  microseconds
                        packetswitched          - between 49,512 and 245,760
                                                  microseconds
                        long, satellite         - more than 245760 microseconds.
                        maximum                 - the maximum propagation delay. "
        ::= { nwAppnFwdLsEntry 21 }

nwAppnFwdLsUsrDef1  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 1. "
        DEFVAL { 128 }
        ::= { nwAppnFwdLsEntry 22 }

nwAppnFwdLsUsrDef2  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 2. "
        DEFVAL { 128 }
        ::= { nwAppnFwdLsEntry 23 }

nwAppnFwdLsUsrDef3  OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies user defined parameter 3. "
        DEFVAL { 128 }
        ::= { nwAppnFwdLsEntry 24 }

nwAppnFwdLsTrgtPacingCount  OBJECT-TYPE
        SYNTAX  INTEGER (0..32767)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Species the desired pacing window size for BINDs on this
                transmission group. The number is a value between 0 and 32767
                and is significant only when fixed bind pacing is being used."
        DEFVAL { 7 }
        ::= { nwAppnFwdLsEntry 25 }

nwAppnFwdLsMaxSendBtu  OBJECT-TYPE
        SYNTAX  INTEGER (99..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies maximum Message Unit (MU) size that can be sent."
        DEFVAL { 2048 }
        ::= { nwAppnFwdLsEntry 26 }

nwAppnFwdLsNumActiveSession  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies total number of active sessions on this link.
                This includes both end point sessions and intermediate sessions."
        ::= { nwAppnFwdLsEntry 27 }

nwAppnFwdLsdynamicLs  OBJECT-TYPE
        SYNTAX  INTEGER { yes(1), no(2) }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies whether this link station was dynamically
                allocated (yes(1)) or whether the link station was defined by
                the user (no(2))."
        ::= { nwAppnFwdLsEntry 28 }

nwAppnFwdLsStopType  OBJECT-TYPE
        SYNTAX  INTEGER { 
                        immediate(1), 
                        orderly(2) 
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the type of shutdown for a link. Once selected,
                set disable in nwAppnFwdIfAdminStatus. The shutdown choices are
                as follows:

                 immediate(1) causes the link station to disconnect
                              immediately without flushing remaining Message Unit (MU)s.
                 orderly(2)   causes the link station to disconnect
                              after successfully flushing remaining Message Unit (MU)s. "
        DEFVAL { orderly }
        ::= { nwAppnFwdLsEntry 29 }

nwAppnFwdLsPortNbr    OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This link station port number corresponds to the index into
                the nwAppnFwdIfTable and the nwAppnExtensionTable, which 
                together describe the port used by APPN Routing Services."
        ::= { nwAppnFwdLsEntry 30 }

nwAppnFwdLsDestAddr  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (1..32))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the destination address of the adjacent link station
                depending on the media type. For token ring or ethernet ports,
                the information is the 6 byte Destination MAC Address which
                starts in byte 1 and ends in byte 6. For token ring ports, 
                the MAC address must be specified in non-canonical format.
                For ethernet ports the MAC address must be specified in
                canonical format. For frame relay, the  address is a non-null
                terminated string which is the ascii representation of the DLCI."
        ::= { nwAppnFwdLsEntry 31 }

nwAppnFwdLsDsap  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (1))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For a token ring or ethernet network, specifies the destination
                SAP address associated with the adjacent link station.  "
        DEFVAL { '04'h }
        ::= { nwAppnFwdLsEntry 32 }

nwAppnFwdLsBlockNum       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(3))
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This represents the 3 hexadecimal digit block number which 
                precedes the 5 digit id number in the 8 digit node id of the
                adjacent node. The node id is used in XIDs and Alerts. The
                block number identifies the product type. Both the block number
                and id number combined, uniquely identify the adjacent node
                within the installation network."
        ::= { nwAppnFwdLsEntry 33 }

nwAppnFwdLsIdNum    OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(5))
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "This represents the 5 hexadecimal digit id number which follows
                the 3 digit block number in the 8 digit node id of the adjacent
                node. The node id is used in XIDs and Alerts. The id number
                uniquely identifies the adjacent node within a product type
                indicated by its block number. Both the block number and id number
                combined, uniquely identify the adjacent node within the 
                installation network."
        ::= { nwAppnFwdLsEntry 34 }



--  APPN Forwarding Link Station Counter Table

--  APPN Forwarding link station Counter Table
--  This table contains the objects that specify Basic Link Unit (BLU) and
--  byte counters for each configured adjacent link station.
--
nwAppnFwdLsCtrTable         OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwAppnFwdLsCtrEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "This table contains the Basic Link Unit (BLU) and byte
                counters for each configured adjacent link station."
        ::= { nwAppnFwdLsCounters 1 }

nwAppnFwdLsCtrEntry         OBJECT-TYPE
        SYNTAX          NwAppnFwdLsCtrEntry
         ACCESS         not-accessible
        STATUS          mandatory
        DESCRIPTION
                "Each entry indicates the Basic Link Unit (BLU) and byte
                count for the configured adjacent link station for which the
                entry exists. "

        INDEX           { nwAppnFwdLsCtrLsName }
        ::= { nwAppnFwdLsCtrTable 1 }

NwAppnFwdLsCtrEntry ::=
        SEQUENCE {
                nwAppnFwdLsCtrLsName                DisplayString,
                nwAppnFwdLsCtrAdminStatus           INTEGER,
                nwAppnFwdLsCtrReset                 INTEGER,
                nwAppnFwdLsCtrOperationalTime       TimeTicks,
                nwAppnFwdLsCtrInBlus                Counter,
                nwAppnFwdLsCtrOutBlus               Counter,
                nwAppnFwdLsCtrFwdBlus               Counter,
                nwAppnFwdLsCtrFilteredBlus          Counter,
                nwAppnFwdLsCtrDiscardBlus           Counter,
                nwAppnFwdLsCtrAddrErrBlus           Counter,
                nwAppnFwdLsCtrLenErrBlus            Counter,
                nwAppnFwdLsCtrHdrErrBlus            Counter,
                nwAppnFwdLsCtrInBytes               Counter,
                nwAppnFwdLsCtrOutBytes              Counter,
                nwAppnFwdLsCtrFwdBytes              Counter,
                nwAppnFwdLsCtrFilteredBytes         Counter,
                nwAppnFwdLsCtrDiscardBytes          Counter,
                nwAppnFwdLsCtrHostInBlus            Counter,
                nwAppnFwdLsCtrHostOutBlus           Counter,
                nwAppnFwdLsCtrHostDiscardBlus       Counter,
                nwAppnFwdLsCtrHostInBytes           Counter,
                nwAppnFwdLsCtrHostOutBytes          Counter,
                nwAppnFwdLsCtrHostDiscardBytes      Counter
        }

nwAppnFwdLsCtrLsName       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the primary index into the link station 
                counter table. This index is the link station name. "
        ::= { nwAppnFwdLsCtrEntry 1 }

nwAppnFwdLsCtrAdminStatus   OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the administrative state of the Basic Link Unit (BLU)
                and byte counters on the link for which this entry exists.
                enabled(3) causes these counters to reset and become active.
                disabled(2) causes these counters to become inactive. "
        ::= { nwAppnFwdLsCtrEntry 2 }

nwAppnFwdLsCtrReset         OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Resets the Basic Link Unit (BLU) and byte counters on the link
                for which this entry exists. reset(2) resets the counters to 0.
                nwAppnFwdLsCtrOperationalTime is also reset to 0."
        ::= { nwAppnFwdLsCtrEntry 3 }

nwAppnFwdLsCtrOperationalTime        OBJECT-TYPE
        SYNTAX          TimeTicks
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the amount of time in hundreths of a second that the
                Basic Link Unit (BLU) and byte counters have been active on the
                link for which this entry exists."
        ::= { nwAppnFwdLsCtrEntry 4 }

nwAppnFwdLsCtrInBlus        OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the total number of Basic Link Unit (BLU)s that have
                been received, during nwAppnFwdLsCtrOperationaltime, on the link
                for which this entry exists. This includes both information
                (I-frame) and XID BLUs."
        ::= { nwAppnFwdLsCtrEntry 5 }

nwAppnFwdLsCtrOutBlus       OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the total number of Basic Link Unit (BLU)s that have
                been transmitted, during nwAppnFwdLsCtrOperationalTime, on the
                link for which this entry exists. This includes both information
                (I-frame) and XID BLUs."
        ::= { nwAppnFwdLsCtrEntry 6 }

nwAppnFwdLsCtrFwdBlus       OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 7 }

nwAppnFwdLsCtrFilteredBlus OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 8 }

nwAppnFwdLsCtrDiscardBlus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 9 }

nwAppnFwdLsCtrAddrErrBlus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 10 }

nwAppnFwdLsCtrLenErrBlus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of received Basic Link Unit (BLU)s
                during nwAppnFwdLsCtrOperationalTime which have invalid DLC
                headers on the link for which this entry exists." 
        ::= { nwAppnFwdLsCtrEntry 11 }

nwAppnFwdLsCtrHdrErrBlus        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the total number of received Basic Link Unit (BLU)s
                during nwAppnFwdLsCtrOperationalTime which have length errors
                on the link for which this entry exists." 
        ::= { nwAppnFwdLsCtrEntry 12 }

nwAppnFwdLsCtrInBytes      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the total number of bytes that have been received,
                during nwAppnFwdLsCtrOperationalTime, on the link for which
                the entry exists.  This includes bytes contained in 
                information (I-frames) and XID BLUs."
        ::= { nwAppnFwdLsCtrEntry 13 }

nwAppnFwdLsCtrOutBytes     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the total number of bytes that have been transmitted,
                during nwAppnFwdLsCtrOperationalTime, on the link for which the
                entry exists.  This includes bytes contained in information
                (I-frames) and XID BLUs."
        ::= { nwAppnFwdLsCtrEntry 14 }

nwAppnFwdLsCtrFwdBytes     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 15 }

nwAppnFwdLsCtrFilteredBytes        OBJECT-TYPE
        SYNTAX                  Counter
        ACCESS                  read-only
        STATUS                  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 16 }

nwAppnFwdLsCtrDiscardBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 17 }

nwAppnFwdLsCtrHostInBlus   OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 18 }

nwAppnFwdLsCtrHostOutBlus  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 19 }

nwAppnFwdLsCtrHostDiscardBlus      OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 20 }

nwAppnFwdLsCtrHostInBytes  OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 21 }

nwAppnFwdLsCtrHostOutBytes OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 22 }

nwAppnFwdLsCtrHostDiscardBytes     OBJECT-TYPE
        SYNTAX                  Counter
        ACCESS                  read-only
        STATUS                  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnFwdLsCtrEntry 23 }

--  Link State-Based Protocols
--  This group contains the managed objects for Link State protocols for
--  APPN Routing Services.

--  APPN ISR System Group
--  This group contains the managed objects for global, system-wide
--  APPN Intermediate Session Routing (ISR) LinkState based routing protocol.

--  APPN ISR System Configuration Parameters
--  This group contains the objects that pertain to the setup and
--  configuration of the APPN ISR LinkState based routing protocol.



-- Link State-Based Protocols
-- This group contains the objects that apply to the Link State based routing
-- protocols supported by APPN Routing Services.

-- APPN ISR System Group
-- This group contains the objects that pertain to the APPN Intermediate Session
-- Routing (ISR) LinkState-based routing protocol at a system-wide, global level.

-- APPN ISR System Configuration Parameters
-- This group contains the objects that pertain to the setup and configuration
-- of the APPN ISR Link State based routing protocol at a system-wide, global level.


nwAppnIsrAdminStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                  other(1),             --  none of the following
                  disable(2),           --  disable
                  enable(3)             --  enable
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Intermediate Session Routing cannot be turned on and
                 off.  Any modifications to this leaf will have no
                 affect. "
        ::= { nwAppnIsrConfig 1 }

nwAppnIsrOperStatus     OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  inactive
                        enabled(3),           --  active
                        pendingDisable(4),    --  deactivate in progress
                        pendingEnable(5)      --  activate in progress
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the current operating condition of the ISR routing
                protocol, system-wide."
        ::= { nwAppnIsrConfig 2 }

nwAppnIsrAdminReset      OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1)              -- none of the following
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This object does not apply to this protocol. It is a common
                object, inherited from the MIB framework used to provide a
                common management interface to all the Cabletron Routing Services
                protocol-specific MIBs."
        ::= { nwAppnIsrConfig 3 }

nwAppnIsrOperationalTime  OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the elapsed time, in hundredths of a second, that
                nwAppnOperStatus has been in its current state."
        ::= { nwAppnIsrConfig 4 }

nwAppnIsrVersion  OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the current revision level of the ISR firmware in
                textual format. This is the same version number as that of APPN
                Routing Services firmware, nwAppnSysVersion. "
        ::= { nwAppnIsrConfig 5 }


--  APPN Event Group
nwAppnEventAdminStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                                enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Set the administrative state of APPN Routing Services event
                logging. enabled(3) causes the event log to become active.
                disabled(2) causes the event log to become inactive."
        ::= { nwAppnEventLogConfig 1 }

nwAppnEventMaxEntries     OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Sets the maximum number of entries allowed in the event log
                table.  When the number of entries reaches the value of
                nwAppnEventMaxEntries the first (oldest) entry is deleted
                to allow a new entry to be added."
        ::= { nwAppnEventLogConfig 2 }

nwAppnEventTraceAll OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                                enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "enabled(3) allows logging of all event types on all ports.
                disabled(2) causes the filter table to specify which events to
                log."
        ::= { nwAppnEventLogConfig 3 }


-- Event Log Filter Table
-- The Event Log Filter Table contains the managed objects used to setup
-- and configure event log filters for APPN Routing Services events.


nwAppnEventFilterTable            OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwAppnEventFilterEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "This table contains descriptions of how to filter log entries."
        ::= { nwAppnEventLogFilterTable 1 }

nwAppnEventFilterEntry            OBJECT-TYPE
        SYNTAX          NwAppnEventFilterEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "Each entry specifies the filter for log entries.  The
                instance nwAppnEventProtocol refers to the instance used
                in the nwRtgProtocolTable and nwComponentTable specified
                by the ctrouter-mib.txt. "
        INDEX   { nwAppnEventFltrProtocol, nwAppnEventFltrIfNum }
        ::= { nwAppnEventFilterTable 1 }

NwAppnEventFilterEntry ::=
        SEQUENCE {
                nwAppnEventFltrProtocol   INTEGER,
                nwAppnEventFltrIfNum      INTEGER,
                nwAppnEventFltrControl    INTEGER,
                nwAppnEventFltrType       INTEGER,
                nwAppnEventFltrSeverity   INTEGER,
                nwAppnEventFltrAction     INTEGER
        }

nwAppnEventFltrProtocol   OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Selects the protocol to log events from."
        ::= { nwAppnEventFilterEntry 1 }

nwAppnEventFltrIfNum      OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the APPN Routing Services port on which to log events. "
        ::= { nwAppnEventFilterEntry 2 }

nwAppnEventFltrControl    OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                delete(2),
                                add(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
                "Setting this field to delete will allow entries to be
                removed from the table.  This is done by adding new entries
                with instance fields that match the entry to be removed from
                the table.  The new entry being added must have this control
                field set to delete in order for the matching entry already
                in the table to be deleted.  Setting this field to add will
                add the entry to the table."
        ::= { nwAppnEventFilterEntry 3 }

nwAppnEventFltrType        OBJECT-TYPE
        SYNTAX      INTEGER {
                            misc(1),
                            timer(2),
                            rcv(4),
                            xmit(8),
                            event(16),
                            error(32)
            }
        ACCESS      read-write
        STATUS      mandatory
        DESCRIPTION
                "This bit field mask filter will allow only events of
                certain types to be logged.  By default all types will be
                logged.  Clearing event types from this field will cause
                those types not to be logged.  Adding event types to this
                field will enable those types to be logged. "
    ::= { nwAppnEventFilterEntry 4 }

nwAppnEventFltrSeverity   OBJECT-TYPE
        SYNTAX      INTEGER {
                             highest(1),
                             highmed(2),
                             highlow(3)
            }
        ACCESS      read-write
        STATUS      mandatory
        DESCRIPTION
                "This filter controls the amount of logging by ignoring events
                of lower priority than that specified by the filter value.
                Specifying highest(1) causes all events except those of highest
                severity to be ignored. Specifying highmed(2) causes lowest
                severity events to be ignored.  Specifying highlow(3) causes
                all events to be logged.  highmed(2) is the default setting."
    ::= { nwAppnEventFilterEntry 5 }

nwAppnEventFltrAction OBJECT-TYPE
    SYNTAX      INTEGER {
                        log(1),
                        trap(2),
                        logTrap(3)
            }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
                "This field specifies how the events are to be logged.
                Specifying log(1) stores the events in the event log
                table (defined below).  Specifying trap(2) sends events
                out through the trap mechanism. Specifying logTrap(3)
                does both. "
    ::= { nwAppnEventFilterEntry 6 }

--  Event Log Table
--  The Event Log Table contains the logged events.

nwAppnEventTable          OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwAppnEventEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "This table contains all events that have been logged."
        ::= { nwAppnEventLogTable 1 }

nwAppnEventEntry          OBJECT-TYPE
        SYNTAX          NwAppnEventEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
                "Each entry specifies events that have been logged."
        INDEX           { nwAppnEventNumber }
        ::= { nwAppnEventTable 1 }

NwAppnEventEntry ::=
        SEQUENCE {
                nwAppnEventNumber         INTEGER,
                nwAppnEventTime           TimeTicks,
                nwAppnEventType           INTEGER,
                nwAppnEventSeverity       INTEGER,
                nwAppnEventProtocol       INTEGER,
                nwAppnEventIfNum          INTEGER,
                nwAppnEventTextString     OCTET STRING
        }

nwAppnEventNumber         OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This ordinal number uniquely identifies events."
        ::= { nwAppnEventEntry 1 }

nwAppnEventTime           OBJECT-TYPE
        SYNTAX          TimeTicks
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "This number specifies when the event was logged."
        ::= { nwAppnEventEntry 2 }

nwAppnEventType           OBJECT-TYPE
        SYNTAX          INTEGER {
                                misc(1),
                                timer(2),
                                rcv(4),
                                xmit(8),
                                event(16),
                                diags(32),
                                error(64)
                        }
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies type of event logged."
        ::= { nwAppnEventEntry 3 }

nwAppnEventSeverity               OBJECT-TYPE
        SYNTAX          INTEGER {
                                highest(1),
                                highmed(2),
                                highlow(3)
                        }
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the severity of the event logged."
        ::= { nwAppnEventEntry 4 }

nwAppnEventProtocol               OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the protocol where the event occured."
        ::= { nwAppnEventEntry 5 }

nwAppnEventIfNum          OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the APPN Routing Services port the event occurred on."
        ::= { nwAppnEventEntry 6 }

nwAppnEventTextString     OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
                "Specifies the actual text string to be logged."
        ::= { nwAppnEventEntry 7 }

END