CTRON-CSMACD-MIB device MIB details by Enterasys Networks Inc
CTRON-CSMACD-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-CSMACD-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-CSMACD-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-CSMACD-MIB DEFINITIONS ::= BEGIN -- ctron-csmacd-mib.txt -- Revision: 1.06.00 -- Part Number: 2170554-01 -- Date: August 11, 1995 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise-specific CSMACD MIB. -- -- This module will be extended, as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright October 95 Cabletron Systems -- The contents of this MIB is obsolete. Existing products -- still utilize it but all future products will implement -- other MIBs that contain much of this information. IMPORTS Counter FROM RFC1155-SMI ctCSMACD FROM CTRON-MIB-NAMES OBJECT-TYPE FROM RFC-1212; -- The fnbCSMACD group -- Implementation of this group is mandatory for CSMA/CD -- subsystems on devices that incorporate the FNB. ctFnbCSMACD OBJECT IDENTIFIER ::= { ctCSMACD 1 } ctFnbPortConnect OBJECT IDENTIFIER ::= { ctCSMACD 2 } ctFnbCSMACDTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFnbCSMACDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of entries that provide connection status of CSMA/CD subsystems, for the FNB." ::= { ctFnbCSMACD 1 } ctFnbCSMACDEntry OBJECT-TYPE SYNTAX CtFnbCSMACDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ctFnbCSMACDTable containing objects that provide FNB connection status for a CSMA/CD subsystem." INDEX { ctFnbCSMACDIndex } ::= { ctFnbCSMACDTable 1 } CtFnbCSMACDEntry ::= SEQUENCE { ctFnbCSMACDIndex INTEGER, ctFnbConnect INTEGER, ctFnbPortChanges Counter } ctFnbCSMACDIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An unique value for each CSMACD subsystem. Its value ranges between 1 and chassisSlots. The value for each interface must remain constant, at least, from one re-initialization of the entity's network management system to the next re-initialization." ::= { ctFnbCSMACDEntry 1 } ctFnbConnect OBJECT-TYPE SYNTAX INTEGER { connectB(1), connectC(2), disconnect(3), connectA(4), subnetB(5), subnetC(6), multiChannel(7), frontpanel(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Denotes the connection status of the CSMA/CD board to the inter-RIC bus. The values of 1, 2, and 4 define connection status of connect for the subsystem, values 5 and 6 define connection status of subnet connect for the subsystem, value 8 is defined as a front panel connection on the module, and a value of 3 defines disconnect status." ::= { ctFnbCSMACDEntry 2 } ctFnbPortChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Denotes the number of times any port on the given MIM has changed it's connection to the inter-RIC bus." ::= { ctFnbCSMACDEntry 3 } ctFnbPortConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFnbPortConnectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to control port association on ethernet devices. Only those boards that support port switching will be listed in this table." ::= { ctFnbPortConnect 1 } ctFnbPortConnectEntry OBJECT-TYPE SYNTAX CtFnbPortConnectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a specific port connection entry." INDEX { ctFnbPortConnectBoardIndex, ctFnbPortConnectPortIndex } ::= { ctFnbPortConnectTable 1 } CtFnbPortConnectEntry ::= SEQUENCE { ctFnbPortConnectBoardIndex INTEGER, ctFnbPortConnectPortIndex INTEGER, ctFnbPortConnectPortAssignment INTEGER, ctFnbPortCompID INTEGER } ctFnbPortConnectBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An instance of a board for which this port assignment relationship exists." ::= { ctFnbPortConnectEntry 1 } ctFnbPortConnectPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An instance of a port for which this assignment relationship exists." ::= { ctFnbPortConnectEntry 2 } ctFnbPortConnectPortAssignment OBJECT-TYPE SYNTAX INTEGER { connectA(1), connectB(2), connectC(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The specific channel that the port is assigned." ::= { ctFnbPortConnectEntry 3 } ctFnbPortCompID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the component ID as defined in the chassis MIB that this port is associated with. These components will be repeater components." ::= { ctFnbPortConnectEntry 4 } ctFnbPortConnectionChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Maintains the number of times any port within the mangement domain of this MIM changes it's port assignment." ::= { ctFnbPortConnect 2 } END