ActiveXperts Network Monitor 2019##AdminFavorites

CTRON-ENVIRONMENT-MIB by vendor Enterasys Networks Inc

CTRON-ENVIRONMENT-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CTRON-ENVIRONMENT-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-ENVIRONMENT-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
CTRON-ENVIRONMENT-MIB DEFINITIONS ::= BEGIN

        --  ctron-env-mib.txt Environmental MIB
        --  Revision: 1.01.01
        --  Part Number:  2170995
        --  Date: August 16, 1996

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific ct-env MIB.
        --
        --  This module will be extended, as needed.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems

        IMPORTS
                ctenv   
                        FROM CTRON-MIB-NAMES
                OBJECT-TYPE
                        FROM RFC-1212;



        --===============    group definitions     ===================

        chEnv           OBJECT IDENTIFIER  ::= { ctenv 1 }
        boardEnv        OBJECT IDENTIFIER  ::= { ctenv 2 }
        psEnv           OBJECT IDENTIFIER  ::= { ctenv 3 }
        bbuEnv          OBJECT IDENTIFIER  ::= { ctenv 4 }
        
        --    chEnv group          ====================

        --  Chassis Environment Group
        --  Implementation of the Chassis Environment group is optional.
        --  It needs to be supported when an EM is present and operational
        --  in the chassis.
        --  This group covers information on the Temperature & Humidity.
        --  This group also cover the temperature control in the form of
        --  fan speed control.

        chEnvAmbientTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The ambient temperature of the room in which the chassis 
                 is located. If this sensor is broken or not supported, then
                 this object will be set to zero. The value of this object
                 is the actual temperature in degrees Fahrenheit * 10."
            ::= { chEnv 1 }

        chEnvAmbientStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the ambient temperature
                 reading."
            ::= { chEnv 2 }

        chEnvHumidity  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value of the air flowing thru the chassis.
                 The value of this object is the actual humidity * 10."
            ::= { chEnv 3 }

        chEnvHumidityStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        dry(2),
                        normal(3),
                        moist(4),
                        inoperative(5)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the ambient humidity
                 reading."
            ::= { chEnv 4 }

        chEnvAmbientHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the ambient temperature
                 is deemed to be hot."
            ::= { chEnv 5 }

        chEnvAmbientWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the ambient temperature
                 is deemed to be warm, if it is below or equal the hot 
                 value."
            ::= { chEnv 6 }

        chEnvAmbientCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the ambient temperature
                 is deemed to be cool, if it is above or equal the cold
                 value."
            ::= { chEnv 7 }

        chEnvAmbientCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the ambient temperature
                 is deemed to be cold."
            ::= { chEnv 8 }

        chEnvHumidityMoist  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value above which the chassis humidity
                 is deemed to be moist."
            ::= { chEnv 9 }

        chEnvHumidityDry  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The humidity value below which the chassis humidity
                 is deemed to be a static risk."
            ::= { chEnv 10 }

        chEnvNumFans  OBJECT-TYPE
            SYNTAX  INTEGER (0..64)
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Number of fans in a chassis."
            ::= { chEnv 11 }

        chEnvFanTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChEnvFanEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of fans installed in this chassis."
            ::= { chEnv 12 }

        chEnvFanEntry  OBJECT-TYPE
            SYNTAX  ChEnvFanEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { chEnvFanID }
            ::= { chEnvFanTable 1 }

        ChEnvFanEntry  ::=
            SEQUENCE {
                chEnvFanID
                    INTEGER,
                chEnvFanStatus
                    INTEGER,
                chEnvFanAdmin
                    INTEGER,
                chEnvFanSpeed
                    INTEGER
            }

        chEnvFanID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "A unique value, in the range between 1 and and the 
                 value of chEnvNumFans."
            ::= { chEnvFanEntry 1 }

        chEnvFanStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        testing(3),
                        slow(4),                -- Not running a correct speed
                        inoperative(5),
                        off(6)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the chassis fan."
            ::= { chEnvFanEntry 2 }

        chEnvFanAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        autoMode(1),
                        fullSpeed(2),
                        testingMode(3)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object is used to select the operational mode of the 
                 fan. If the value is set to 1 (auto) then fan speed is 
                 based on temperature. If the value is set to 3 (testing) 
                 then value will return to it's previous value prior to 
                 being set at 3."
            DEFVAL { autoMode }
            ::= { chEnvFanEntry 3 }

        chEnvFanSpeed  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The fan speed expressed as a percentage of the maximum 
                 fan speed."
            ::= { chEnvFanEntry 4 }

        --==============    BoardEnv group          ===================

        --  Board Environment Group
        --  This group covers information on the Temperature.
        --  This group also cover the temperature control in the form of
        --  module shutdwon control.

        boardEnvSlotTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF BoardEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of networking modules installed in this chassis."
            ::= { boardEnv 1 }

        boardEnvSlotEntry  OBJECT-TYPE
            SYNTAX  BoardEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { boardEnvSlotID }
            ::= { boardEnvSlotTable 1 }

        BoardEnvSlotEntry  ::=
            SEQUENCE {
                boardEnvSlotID
                    INTEGER,
                boardEnvTemp
                    INTEGER,
                boardEnvTempStatus
                    INTEGER,
                boardEnvTempRelStatus
                    INTEGER,
                boardEnvShutdownAdmin
                    INTEGER,
                boardEnvTempHot
                    INTEGER,
                boardEnvTempWarm
                    INTEGER,
                boardEnvTempCool
                    INTEGER,
                boardEnvTempCold
                    INTEGER,
                boardEnvTempRelHot
                    INTEGER,
                boardEnvTempRelWarm
                    INTEGER,
                boardEnvTempMaxFanRelHot
                    INTEGER,
                boardEnvTempMaxFanRelWarm
                    INTEGER
            }

        boardEnvSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The slot number of a chassis slot in which this board is
                 installed.  This object is similiar to chSlotID in the
                 Chassis MIB."
            ::= { boardEnvSlotEntry 1 }

        boardEnvTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature of the networking board. If this sensor is 
                 broken or not supported, then this object will be set to 
                 zero. The temperature is in degrees Fahrenheit * 10."
            ::= { boardEnvSlotEntry 2 }

        boardEnvTempStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the board temperature
                 reading."
            ::= { boardEnvSlotEntry 3 }

        boardEnvTempRelStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        warm(3),
                        hot(4),
                        inoperative(5)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the board temperature
                 reading relative to the ambient temperature."
            ::= { boardEnvSlotEntry 4 }

        boardEnvShutdownAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        enabled(1),
                        disabled(2)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object enables or disables the auto shutdown due
                 to a temperature condition."
            DEFVAL { disabled }
            ::= { boardEnvSlotEntry 5 }

        boardEnvTempHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the board temperature
                 is deemed to be hot."
            ::= { boardEnvSlotEntry 6 }

        boardEnvTempWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the board temperature
                 is deemed to be warm, if it is below or equal the hot 
                 value."
            ::= { boardEnvSlotEntry 7 }

        boardEnvTempCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the board temperature
                 is deemed to be cool, if it is above or equal the cold
                 value."
            ::= { boardEnvSlotEntry 8 }

        boardEnvTempCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the board temperature
                 is deemed to be cold."
            ::= { boardEnvSlotEntry 9 }

        boardEnvTempRelHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board
                 temperature is deemed to be hot relative to ambient."
            ::= { boardEnvSlotEntry 10 }

        boardEnvTempRelWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board 
                 temperature is deemed to be warm relative to ambient, if
                 it is below the relative hot value of boardEnvTempRelHot."
            ::= { boardEnvSlotEntry 11 }

        boardEnvTempMaxFanRelHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board
                 temperature is deemed to be hot relative to ambient, with
                 all fans in the chassis running at there maximum speed."
            ::= { boardEnvSlotEntry 12 }

        boardEnvTempMaxFanRelWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above ambient at which the board 
                 temperature is deemed to be warm relative to ambient, if
                 it is below the relative hot value of boardEnvTempMaxFanRelHot,
                 with all fans in the chassis running at there maximum speed."
            ::= { boardEnvSlotEntry 13 }

        --===============    psEnv group          ====================

        --  Power Supply Environment Group
        --  This group covers information on the Temperature .
        --  This group also cover the temperature control in the form of
        --  power supply fan control.

        psEnvSlotTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF PsEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of networking modules installed in this chassis."
            ::= { psEnv 1 }

        psEnvSlotEntry  OBJECT-TYPE
            SYNTAX  PsEnvSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { psEnvSlotID }
            ::= { psEnvSlotTable 1 }

        PsEnvSlotEntry  ::=
            SEQUENCE {
                psEnvSlotID
                    INTEGER,
                psEnvTemp
                    INTEGER,
                psEnvTempStatus
                    INTEGER,
                psEnvTempHot
                    INTEGER,
                psEnvTempWarm
                    INTEGER,
                psEnvTempCool
                    INTEGER,
                psEnvTempCold
                    INTEGER,
                psEnvFanStatus
                    INTEGER,
                psEnvFanAdmin
                    INTEGER,
                psEnvFanSpeed
                    INTEGER
            }

        psEnvSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The slot number of a chassis slot in which this power supply
                 is installed.  An unique value, in the range between 1 and 
                 and the value of chNumSlots.  This object is similiar to
                 chSlotID in the Chassis MIB."
            ::= { psEnvSlotEntry 1 }

        psEnvTemp  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature of the power supply. If this sensor is 
                 broken or not supported, then this object will be set to 
                 zero. The temperature is in degrees Fahrenheit * 10."
            ::= { psEnvSlotEntry 2 }

        psEnvTempStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        cold(2),
                        cool(3),
                        normal(4),
                        warm(5),
                        hot(6),
                        inoperative(7)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the power supply
                 temperature reading."
            ::= { psEnvSlotEntry 3 }

        psEnvTempHot  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the power supply
                 temperature is deemed to be hot."
            ::= { psEnvSlotEntry 4 }

        psEnvTempWarm  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value above which the power supply 
                 temperature is deemed to be warm, if it is below or
                 equal the hot value."
            ::= { psEnvSlotEntry 5 }

        psEnvTempCool  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the power supply 
                 temperature is deemed to be cool, if it is above or 
                 equal the cold value."
            ::= { psEnvSlotEntry 6 }

        psEnvTempCold  OBJECT-TYPE
            SYNTAX  INTEGER 
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The temperature value below which the power supply
                 temperature is deemed to be cold."
            ::= { psEnvSlotEntry 7 }

        psEnvFanStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        normal(2),
                        testing(3),
                        slow(4),                -- not running a set speed
                        inoperative(5),
                        off(6)
                }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "This object reflects the status of the chassis fan."
            ::= { psEnvSlotEntry 8 }

        psEnvFanAdmin  OBJECT-TYPE
            SYNTAX  INTEGER {
                        autoMode(1),
                        fullSpeed(2),
                        testingMode(3)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This object is used to select the operational mode of the 
                 fan. If the value is set to 1 (auto) then fan speed is 
                 based on temperature. If the value is set to 3 (testing) 
                 then value will return to it's previous value prior to 
                 being set at 3."
            DEFVAL { autoMode }
            ::= { psEnvSlotEntry 9 }

        psEnvFanSpeed  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The fan speed expressed as a percentage of the maximum 
                 fan speed."
            ::= { psEnvSlotEntry 10 }