CTRON-FDDI-FNB-MIB device MIB details by Enterasys Networks Inc
CTRON-FDDI-FNB-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-FDDI-FNB-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-FDDI-FNB-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-FDDI-FNB-MIB DEFINITIONS ::= BEGIN -- CTRON-FDDI-FNB-mib.txt The FDDI FNB backplane control MIB -- Revision: 1.01.00 -- Date: September 13, 1995 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise-specific connection MIB. -- -- This module will be extended, as needed. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright August 95 Cabletron Systems IMPORTS Counter FROM RFC1155-SMI ctFDDIFnb FROM CTRON-MIB-NAMES DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- DisplayString ::= OCTET STRING -- This MIB module uses the extended OBJECT-TYPE macro as defined -- RFC 1212 --====== group definitions =========== ctFDDIResource OBJECT IDENTIFIER ::= { ctFDDIFnb 1 } ctFDDINonMux OBJECT IDENTIFIER ::= { ctFDDIFnb 2 } ctFDDIMux OBJECT IDENTIFIER ::= { ctFDDIFnb 3 } ctFDDISerialConfig OBJECT IDENTIFIER ::= { ctFDDIFnb 4 } --===== ctFDDIResource group ======== ctFDDIResourceTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIResourceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table specifies the physical resources associated with the FNB and general FNB operation for a particular module in a particular slot." ::= { ctFDDIResource 1 } ctFDDIResourceEntry OBJECT-TYPE SYNTAX CtFDDIResourceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Defines a specific physical resource entry" INDEX { ctFDDIResourceSlotID, ctFDDIResourceID } ::= { ctFDDIResourceTable 1 } CtFDDIResourceEntry ::= SEQUENCE { ctFDDIResourceSlotID INTEGER, ctFDDIResourceID INTEGER, ctFDDIResourceType OBJECT IDENTIFIER, ctFDDIResourceNumbInstance INTEGER } ctFDDIResourceSlotID OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "A specific instance of a slot as defined by chSlotID as defined in the chassis MIB." ::= { ctFDDIResourceEntry 1 } ctFDDIResourceID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB." ::= { ctFDDIResourceEntry 2 } ctFDDIResourceType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the type of resource. This is the same value as chResourceType in the chassis MIB." ::= { ctFDDIResourceEntry 3 } ctFDDIResourceNumbInstance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of a resource from the top to the bottom, then the numbering will start from the left side and proceed top-to-bottom in each column. For instance, the first FNB ring will be instance 1 (top in the chassis) while the second FNB ring is instance 2 (below FNB 1 in the backplane)." ::= { ctFDDIResourceEntry 4 } -- The ctFDDINonMuxGroup -- This group pertains to all devices that provide FDDI conectivity -- which are not multiplexed. ctFDDINonMuxCapTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDINonMuxCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis." ::= { ctFDDINonMux 1 } ctFDDINonMuxCapEntry OBJECT-TYPE SYNTAX CtFDDINonMuxCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a particular capability/configuration entry." INDEX { ctFDDINMSlot, ctFDDINMConfigID } ::= { ctFDDINonMuxCapTable 1 } CtFDDINonMuxCapEntry ::= SEQUENCE { ctFDDINMSlot INTEGER, ctFDDINMConfigID INTEGER, ctFDDINMConfig DisplayString, ctFDDINMConfigDesc DisplayString } ctFDDINMSlot OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "The slot within the chassis for which this configuration information is defined." ::= { ctFDDINonMuxCapEntry 1 } ctFDDINMConfigID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The instance of a particular configuration." ::= { ctFDDINonMuxCapEntry 2 } ctFDDINMConfig OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string, using a specified format for interpretation. The connection specifications are in groups of four where each group defines a specific connection configuration. The terms of a connection group is defined as follows: 1st - The resource ID as defined by ctFDDIResourceID. 2nd - A specific instance of the physical resource. This will be a value between 1 and ctFDDIResourceNumbInstance for the particular resource ID in the first term. If a resource ID has more than one specific resource instance, but the whole resource can be connected, then this term will have the value '0' to signify all instances of the resource. 3rd - The connection ID for this specific physical resource. This value is the same as ctFDDINMConnectionID, and through the ctFDDINonMuxConnectionTable maps to a specific instance of SMT and MAC. For example if the value of this object is '1.1.2.2.1.1', then it states that resource 1, instance 1 is connected to connection ID 2 and resource 2, instance 1 is connected to connection ID 1 and is inserted into its FDDI ring. If a valid configuration is no connections then this object will have a value of '0.0.0'" ::= { ctFDDINonMuxCapEntry 3 } ctFDDINMConfigDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDINMConfig object." ::= { ctFDDINonMuxCapEntry 4 } ctFDDINonMuxCapEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDINonMuxCapEnableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes the currently enabled configuration for each module." ::= { ctFDDINonMux 2 } ctFDDINonMuxCapEnableEntry OBJECT-TYPE SYNTAX CtFDDINonMuxCapEnableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a specific configuration enable entry." INDEX { ctFDDINMEnableSlot } ::= { ctFDDINonMuxCapEnableTable 1 } CtFDDINonMuxCapEnableEntry ::= SEQUENCE { ctFDDINMEnableSlot INTEGER, ctFDDINMCapEnable INTEGER } ctFDDINMEnableSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific slot for which this configuration enable pertains." ::= { ctFDDINonMuxCapEnableEntry 1 } ctFDDINMCapEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object. This object, when read, will return the value of ctFDDINMConfigID for the presently enabled configuration." ::= { ctFDDINonMuxCapEnableEntry 2 } ctFDDINonMuxConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDINonMuxConnectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC instance in the 1512 FDDI MIB." ::= { ctFDDINonMux 3 } ctFDDINonMuxConnectionEntry OBJECT-TYPE SYNTAX CtFDDINonMuxConnectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Defines a specific configuration connection entry." INDEX { ctFDDINMConnectionSlot, ctFDDINMConnectionID } ::= { ctFDDINonMuxConnectionTable 1 } CtFDDINonMuxConnectionEntry ::= SEQUENCE { ctFDDINMConnectionSlot INTEGER, ctFDDINMConnectionID INTEGER, ctFDDINMSMT INTEGER, ctFDDINMMAC INTEGER, ctFDDINMBytes INTEGER, ctFDDINMFrames INTEGER } ctFDDINMConnectionSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific slot for which this connection entry is defined." ::= { ctFDDINonMuxConnectionEntry 1 } ctFDDINMConnectionID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Describes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCapEnable." ::= { ctFDDINonMuxConnectionEntry 2 } ctFDDINMSMT OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific instance of SMT for which this entry pertains." REFERENCE "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex" ::= { ctFDDINonMuxConnectionEntry 3 } ctFDDINMMAC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific MAC that this connection entry pertains." REFERENCE "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex" ::= { ctFDDINonMuxConnectionEntry 4 } ctFDDINMBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bandwidth utilization in bytes per second." ::= { ctFDDINonMuxConnectionEntry 5 } ctFDDINMFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bandwidth utilization in frames per second." ::= { ctFDDINonMuxConnectionEntry 6 } ctFDDINonMuxInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDINonMuxInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describs the number of interfaces defined by each non multiplexing FDDI FNB module." ::= { ctFDDINonMux 4 } ctFDDINonMuxInterfaceEntry OBJECT-TYPE SYNTAX CtFDDINonMuxInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specfic non multiplexing module interface definition." INDEX { ctFDDINMInterSlot } ::= { ctFDDINonMuxInterfaceTable 1 } CtFDDINonMuxInterfaceEntry ::= SEQUENCE { ctFDDINMInterSlot INTEGER, ctFDDINMNumbInterfaces INTEGER } ctFDDINMInterSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific slot for which this inteface entry is defined." ::= { ctFDDINonMuxInterfaceEntry 1 } ctFDDINMNumbInterfaces OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of interfaces defined on this particular module." ::= { ctFDDINonMuxInterfaceEntry 2 } -- the ctFDDIMuxGroup -- This groups controls those devices that perform a FDDI multiplexing -- operation ctFDDIMuxCapTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIMuxCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes all possible configuration/capabilities defined for a FDDI multiplexing module." ::= { ctFDDIMux 1 } ctFDDIMuxCapEntry OBJECT-TYPE SYNTAX CtFDDIMuxCapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a specfic FDDI multiplexor capability/configuration entry." INDEX { ctFDDIMuxSlot, ctFDDIMuxConfig } ::= { ctFDDIMuxCapTable 1 } CtFDDIMuxCapEntry ::= SEQUENCE { ctFDDIMuxSlot INTEGER, ctFDDIMuxConfigID INTEGER, ctFDDIMuxConfig DisplayString, ctFDDIMuxConfigDesc DisplayString } ctFDDIMuxSlot OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "Defines the slot within the chassis for which this multiplexed capability/configuration entry pertains." ::= { ctFDDIMuxCapEntry 1 } ctFDDIMuxConfigID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The instance of a particular configuration." ::= { ctFDDIMuxCapEntry 2 } ctFDDIMuxConfig OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string, using a specified format for interpretation. The specific connections are in groups of four where each group defines a specific connection configuration. The terms of the connection group are defined as follows: 1st - Resource ID. The value is the same as ctFDDIResourceID for a specific resource entry. 2nd - Instance of the resource. This has a value in the range of 1 to ctFDDIResourceNumbInstance. 3rd - Path of the resource as input to the multiplexor. Paths are specified as 1 for the primary ring and 2 for the secondary. 4th - This is the multiplexor output channel that this resource comes out of the multiplexor. This value is the same as a value of ctFDDIMuxOutID. 5th - Ring Connectivity. This sub-identifier describes if the given mux-in resource (sub-identifiers 1-3) is inserted into the backplane FNB ring. Valid values are 0 for no 1 for yes. So for example a value of 1.1.1.1.0.2.2.2.2.1 is resource 1, instance 1 (primary) is on mux-out 1 and it's not inserted; resource 2, instance 2 (secondary) is on mux-out 2 and is inserted into the backplane. If a valid configuration is no connections then this object will have a value of '0.0.0.0.0'" ::= { ctFDDIMuxCapEntry 3 } ctFDDIMuxConfigDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDIMuxConfig object." ::= { ctFDDIMuxCapEntry 4 } ctFDDIMuxCapEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIMuxCapEnableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes the currently enabled configuration for each module." ::= { ctFDDIMux 2 } ctFDDIMuxCapEnableEntry OBJECT-TYPE SYNTAX CtFDDIMuxCapEnableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a specific configuration enable entry." INDEX { ctFDDIMuxEnableSlot } ::= { ctFDDIMuxCapEnableTable 1 } CtFDDIMuxCapEnableEntry ::= SEQUENCE { ctFDDIMuxEnableSlot INTEGER, ctFDDIMuxCapEnable INTEGER, ctFDDIMuxMasterPortAssignmentChange Counter } ctFDDIMuxEnableSlot OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "A specific slot for which this configuration enable pertains." ::= { ctFDDIMuxCapEnableEntry 1 } ctFDDIMuxCapEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request of the value of this object will return the value of ctFDDIMuxConfigID for the presently enabled configuration." ::= { ctFDDIMuxCapEnableEntry 2 } ctFDDIMuxMasterPortAssignmentChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Depicts the number of changes to the master port to multiplexor output mapping." ::= { ctFDDIMuxCapEnableEntry 3 } ctFDDIMuxOutTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIMuxOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI MIB." ::= { ctFDDIMux 3 } ctFDDIMuxOutEntry OBJECT-TYPE SYNTAX CtFDDIMuxOutEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a particular multiplexor output." INDEX { ctFDDIMuxOutSlot, ctFDDIMuxOutID } ::= { ctFDDIMuxOutTable 1 } CtFDDIMuxOutEntry ::= SEQUENCE { ctFDDIMuxOutSlot INTEGER, ctFDDIMuxOutID INTEGER, ctFDDIMuxOutMACIndex INTEGER, ctFDDIMuxOutSMTIndex INTEGER, ctFDDIMuxBytes INTEGER, ctFDDIMuxFrames INTEGER } ctFDDIMuxOutSlot OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The given slot for which this multiplexor output information pertains." ::= { ctFDDIMuxOutEntry 1 } ctFDDIMuxOutID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig." ::= { ctFDDIMuxOutEntry 2 } ctFDDIMuxOutMACIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has the value of 0, the given mux-out does not have a MAC." REFERENCE "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex" ::= { ctFDDIMuxOutEntry 3 } ctFDDIMuxOutSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the instance of SMT as defined within the FDDI MIB." REFERENCE "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex" ::= { ctFDDIMuxOutEntry 4 } ctFDDIMuxBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bandwidth utilization in bytes per second." ::= { ctFDDIMuxOutEntry 5 } ctFDDIMuxFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The bandwidth utilization in frames per second." ::= { ctFDDIMuxOutEntry 6 } ctFDDIMuxMasterPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIMuxMasterPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of entries that define master ports as they are defined for the given multiplexed FDDI connection." ::= { ctFDDIMux 4 } ctFDDIMuxMasterPortEntry OBJECT-TYPE SYNTAX CtFDDIMuxMasterPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific FDDI-FNB multiplexed master port definition." INDEX { ctFDDIMuxMasterPortSlotID, ctFDDIMuxMasterPortID } ::= { ctFDDIMuxMasterPortTable 1 } CtFDDIMuxMasterPortEntry ::= SEQUENCE { ctFDDIMuxMasterPortSlotID INTEGER, ctFDDIMuxMasterPortID INTEGER, ctFDDIMuxMasterPortAssignment INTEGER, ctFDDIMuxMasterPortIndex INTEGER } ctFDDIMuxMasterPortSlotID OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "A specific instance of a slot as defined by chSlotID." ::= { ctFDDIMuxMasterPortEntry 1 } ctFDDIMuxMasterPortID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for this specific master port." ::= { ctFDDIMuxMasterPortEntry 2 } ctFDDIMuxMasterPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Provides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment." ::= { ctFDDIMuxMasterPortEntry 3 } ctFDDIMuxMasterPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Defines a specific port within the FDDI MIBs fddimibPORTTable." REFERENCE "The IETF RFC FDDI-SMT73-MIB, fddimibPORTIndex" ::= { ctFDDIMuxMasterPortEntry 4 } -- The ctFDDISerialControl group -- This group describes the control over the FDDI serial controlled -- modules. ctFDDINumbModules OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found within the ctFDDISerialConfigTable." ::= { ctFDDISerialConfig 1 } ctFDDISerialConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDISerialConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes the adminstrative control over each of the FNB serial control modules." ::= { ctFDDISerialConfig 2 } ctFDDISerialConfigEntry OBJECT-TYPE SYNTAX CtFDDISerialConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes the controls over a single FNB serial control entry." INDEX { ctFDDISerialSlotID } ::= { ctFDDISerialConfigTable 1 } CtFDDISerialConfigEntry ::= SEQUENCE { ctFDDISerialSlotID INTEGER, ctFDDISerialAdminStatus INTEGER, ctFDDISerialOperStatus INTEGER } ctFDDISerialSlotID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB." ::= { ctFDDISerialConfigEntry 1 } ctFDDISerialAdminStatus OBJECT-TYPE SYNTAX INTEGER { insertFNB1(1), insertFNB2(2), insertFNB1FNB2(3), bypass(4), hwControlFNB1(5), hwControlFNB2(6), hwControl(7) -- Use hardware control } ACCESS read-write STATUS mandatory DESCRIPTION "Describes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and bypass FNB-2. insertFNB2(2) - The serial contolled module should be inserted into FNB-2 and bypass FNB-1. insertFNB1FNB2(3) - Insert the serial controlled module on both FNBs. bypass(4) - Bypass the connection to both FNBs. hwControlFNB1(5) - Use hardware settings for FNB-1. hwControlFNB2(6) - Use hardware settings for FNB-2. hwControl(7) - Use the hardware settings for both FNBs." ::= { ctFDDISerialConfigEntry 2 } ctFDDISerialOperStatus OBJECT-TYPE SYNTAX INTEGER { insertFNB1(1), insertFNB2(2), insertFNB1FNB2(3), bypass(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Describes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from FNB-2. insertFNB2(2) - The serial controlled module is bypassed from FNB-1 and inserted into FNB-2. insertFNB1FNB2(3) - The serial controlled module is inserted into both FNB-1 and FNB-2. bypass(4) - The serial controlled module is bypassed from both FNB-1 and FNB-2." ::= { ctFDDISerialConfigEntry 3 } ctFDDIModuleFPIMTable OBJECT-TYPE SYNTAX SEQUENCE OF CtFDDIModuleFPIMEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs." ::= { ctFDDISerialConfig 3 } ctFDDIModuleFPIMEntry OBJECT-TYPE SYNTAX CtFDDIModuleFPIMEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a single FDDI FPIM on a module." INDEX { ctFddiFPIMSlotID, ctFddiFPIM } ::= { ctFDDIModuleFPIMTable 1 } CtFDDIModuleFPIMEntry ::= SEQUENCE { ctFddiFPIMSlotID INTEGER, ctFddiFPIM INTEGER, ctFddiFPIMStatus INTEGER, ctFddiFPIMType OBJECT IDENTIFIER } ctFddiFPIMSlotID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB." ::= { ctFDDIModuleFPIMEntry 1 } ctFddiFPIM OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of ports from the top to the bottom, then the numbering will start from the left side and proceed top-to-bottom in each column." ::= { ctFDDIModuleFPIMEntry 2 } ctFddiFPIMStatus OBJECT-TYPE SYNTAX INTEGER { link(1), noLink(2), notSupported(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Describes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of notSupported(3) means that link status is not supported by this port and is unknown." ::= { ctFDDIModuleFPIMEntry 4 } ctFddiFPIMType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Describes the type of FPIM as found in ctron-oids." ::= { ctFDDIModuleFPIMEntry 5 } END