AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTRON-IPX-ROUTER-MIB

CTRON-IPX-ROUTER-MIB device MIB details by Enterasys Networks Inc

CTRON-IPX-ROUTER-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-IPX-ROUTER-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-IPX-ROUTER-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTRON-IPX-ROUTER-MIB  DEFINITIONS ::= BEGIN

--  ctron-ipx-router-mib.txt
--  Revision: 1.01.03
--  Part Number: 2170987
--  Date: August 11, 1995

--  Cabletron Systems, Inc.
--  35 Industrial Way, P.O. Box 5005
--  Rochester, NH 03867-0505
--  (603) 332-9400
--  support@ctron.com

--  This module provides authoritative definitions for Cabletron's
--  enterprise specific IPX Routing Services MIB.
--
--
--  This module will be extended as required.
--
--  Cabletron Systems reserves the right to make changes in
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.


--  Copyright August 95 Cabletron Systems


IMPORTS
      OBJECT-TYPE
                FROM RFC-1212
      DisplayString, PhysAddress
                FROM RFC1213-MIB
      MacAddress
                FROM BRIDGE-MIB
      nwRtrProtoSuites
                FROM ROUTER-OIDS
      Counter, TimeTicks, Gauge
                FROM RFC1155-SMI;


--  The IPX Router Group.

nwIpxRouter             OBJECT IDENTIFIER ::= { nwRtrProtoSuites 2 }

nwIpxMibs               OBJECT IDENTIFIER ::= { nwIpxRouter 1 }
nwIpxComponents         OBJECT IDENTIFIER ::= { nwIpxRouter 2 }

--  IPX Router Component Groups

nwIpxSystem             OBJECT IDENTIFIER ::= { nwIpxComponents 1 }
nwIpxForwarding         OBJECT IDENTIFIER ::= { nwIpxComponents 2 }
nwIpxTopology           OBJECT IDENTIFIER ::= { nwIpxComponents 4 }
nwIpxFib                OBJECT IDENTIFIER ::= { nwIpxComponents 5 }
nwIpxEndSystems         OBJECT IDENTIFIER ::= { nwIpxComponents 6 }
nwIpxAccessControl      OBJECT IDENTIFIER ::= { nwIpxComponents 7 }
nwIpxFilters            OBJECT IDENTIFIER ::= { nwIpxComponents 8 }
nwIpxRedirector         OBJECT IDENTIFIER ::= { nwIpxComponents 9 }
nwIpxEvent              OBJECT IDENTIFIER ::= { nwIpxComponents 10 }
nwIpxWorkGroup          OBJECT IDENTIFIER ::= { nwIpxComponents 11 }


--  IPX Router System Groups

nwIpxSysConfig          OBJECT IDENTIFIER ::= { nwIpxSystem 1 }
nwIpxSysAdministration  OBJECT IDENTIFIER ::= { nwIpxSystem 2 }

--  IPX Router Forwarding Groups

nwIpxFwdSystem          OBJECT IDENTIFIER ::= { nwIpxForwarding 1 }
nwIpxFwdInterfaces      OBJECT IDENTIFIER ::= { nwIpxForwarding 2 }

nwIpxFwdCounters        OBJECT IDENTIFIER ::= { nwIpxFwdSystem 1 }
nwIpxFwdIfConfig        OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 1 }
nwIpxFwdIfCounters      OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 2 }


--  IPX Router Routing Groups

nwIpxDistanceVector     OBJECT IDENTIFIER ::= { nwIpxTopology 1 }
nwIpxLinkState          OBJECT IDENTIFIER ::= { nwIpxTopology 2 }

nwIpxRip                OBJECT IDENTIFIER ::= { nwIpxDistanceVector 1 }
nwIpxSap                OBJECT IDENTIFIER ::= { nwIpxDistanceVector 2 }

nwIpxRipSystem          OBJECT IDENTIFIER ::= { nwIpxRip 1 }
nwIpxRipInterfaces      OBJECT IDENTIFIER ::= { nwIpxRip 2 }
nwIpxRipDatabase        OBJECT IDENTIFIER ::= { nwIpxRip 3 }
nwIpxRipFilters         OBJECT IDENTIFIER ::= { nwIpxRip 4 }

nwIpxRipConfig          OBJECT IDENTIFIER ::= { nwIpxRipSystem 1 }
nwIpxRipCounters        OBJECT IDENTIFIER ::= { nwIpxRipSystem 2 }

nwIpxRipIfConfig        OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 1 }
nwIpxRipIfCounters      OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 2 }

nwIpxSapSystem          OBJECT IDENTIFIER ::= { nwIpxSap 1 }
nwIpxSapInterfaces      OBJECT IDENTIFIER ::= { nwIpxSap 2 }
nwIpxSapServerTable     OBJECT IDENTIFIER ::= { nwIpxSap 3 }
nwIpxSapFilters         OBJECT IDENTIFIER ::= { nwIpxSap 4 }

nwIpxSapConfig          OBJECT IDENTIFIER ::= { nwIpxSapSystem 1 }
nwIpxSapCounters        OBJECT IDENTIFIER ::= { nwIpxSapSystem 2 }

nwIpxSapIfConfig        OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 1 }
nwIpxSapIfCounters      OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 2 }

nwIpxNlsp               OBJECT IDENTIFIER ::= { nwIpxLinkState 1 }

--  IPX Router Host End Systems Groups

nwIpxHostsSystem        OBJECT IDENTIFIER ::= { nwIpxEndSystems 1 }
nwIpxHostsInterfaces    OBJECT IDENTIFIER ::= { nwIpxEndSystems 2 }
nwIpxHostsToMedia        OBJECT IDENTIFIER ::= { nwIpxEndSystems 3 }

--  IPX Router Access Control Group

--  IPX Router Redirector Group

nwIpxNetBIOS        OBJECT IDENTIFIER ::= { nwIpxRedirector 1 }
nwIpxBroadcast        OBJECT IDENTIFIER ::= { nwIpxRedirector 2 }
nwIpxEcho            OBJECT IDENTIFIER ::= { nwIpxRedirector 3 }

nwIpxNetBIOSSystem    OBJECT IDENTIFIER ::= { nwIpxNetBIOS 1 }
nwIpxNetBIOSInterface    OBJECT IDENTIFIER ::= { nwIpxNetBIOS 2 }

nwIpxNetBIOSConfig    OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 1 }
nwIpxNetBIOSCounters      OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 2 }

nwIpxNetBIOSIfConfig    OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 1}
nwIpxNetBIOSIfCounters  OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 2}

nwIpxBroadcastSystem    OBJECT IDENTIFIER ::= { nwIpxBroadcast 1 }
nwIpxBroadcastInterface OBJECT IDENTIFIER ::= { nwIpxBroadcast 2 }

nwIpxBroadcastConfig    OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 1 }
nwIpxBroadcastCounters    OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 2 }

nwIpxBroadcastIfConfig        OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 1 }
nwIpxBroadcastIfCounters    OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 2 }

nwIpxEchoSystem        OBJECT IDENTIFIER ::= { nwIpxEcho 1 }
nwIpxEchoInterface    OBJECT IDENTIFIER ::= { nwIpxEcho 2 }

nwIpxEchoConfig        OBJECT IDENTIFIER ::= { nwIpxEchoSystem 1 }
nwIpxEchoCounters    OBJECT IDENTIFIER ::= { nwIpxEchoSystem 2 }

nwIpxEchoIfConfig    OBJECT IDENTIFIER ::= { nwIpxEchoInterface 1 }
nwIpxEchoIfCounters    OBJECT IDENTIFIER ::= { nwIpxEchoInterface 2 }

--  IPX Router Event Log Group

nwIpxEventLogConfig           OBJECT IDENTIFIER ::= { nwIpxEvent 1 }
nwIpxEventLogFilterTable      OBJECT IDENTIFIER ::= { nwIpxEvent 2 }
nwIpxEventLogTable            OBJECT IDENTIFIER ::= { nwIpxEvent 3 }


--  IPX Router Work-Group Group

IpxAddress ::= OCTET STRING
-- MacAddress ::= OCTET STRING (SIZE (6))


--  IPX MIB Group
--  This group contains information about the revision level of this
--  MIB within the device.  It allows verification of the released
--  version without having to read other objects.

nwIpxMibRevText OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current revision level of the IPX MIB in textual 
        format."
    ::= { nwIpxMibs 1 }


--  IPX Router System Group
--  This group contains the objects related to the IPX Router at a
--  global device-wide level.

--  IPX System Configuration Group
--  This group contains the objects that pertain to the setup and
--  configuration of the IPX routing services at a global,
--  device-wide level.

nwIpxSysRouterId   OBJECT-TYPE
    SYNTAX  IpxAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The IPX Address used to uniquely identify the host (device) running
        IPX Routing Services. The value of nwIpxSysRouterId is equal to the
        highest IPX address assigned in the IPX Address Table."
    ::= { nwIpxSysConfig 1 }

--  IPX System Administration Group
--  This group contains the objects that pertain to the administration of
--  IPX routing services at a global, device-wide level.

nwIpxSysAdminStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  shutdown the router
                        enabled(3)            --  startup the router
        }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Sets the administrative state of IPX Routing Services system-wide.
        Enabled (3) causes IPX Routing Services to become active on all router
        ports configured and enabled for IPX Routing Services. Disabled (2)
        causes IPX routing services to become inactive system-wide."
    DEFVAL { disabled }    
    ::= { nwIpxSysAdministration 1 }

nwIpxSysOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
        }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the operating condition of IPX Routing Services system-wide.
        The value of nwIpxSysOperStatus indicates any problem with your IPX
        Routing Services configuration. A value of 6 indicates that regardless
        of the value of nwIpxSysAdminStatus, IPX Routing Services is not
        operating because of an invalid configuration."
    ::= { nwIpxSysAdministration 2 }

nwIpxSysAdminReset      OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Resets IPX Routing Services system-wide. Reset (2) forces a restart
        of IPX Routing Services without a graceful shutdown on any active
        router ports and without affecting any other routing services."
    DEFVAL { other }     
    ::= { nwIpxSysAdministration 3 }

nwIpxSysOperationalTimel  OBJECT-TYPE
    SYNTAX  TimeTicks 
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxSysOperStatus has been in its current administrative state."
    ::= { nwIpxSysAdministration 4 }

nwIpxSysVersion  OBJECT-TYPE
    SYNTAX  DisplayString 
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current revision level of the IPX Routing Services
        firmware in textual format."
    ::= { nwIpxSysAdministration 5 }


--  IPX Forwarding Group
--  This group contains the managed objects used to setup and configure
--  the IPX router port  for packet forwarding as well as the aggregate
--  and per-interface IPX packet forwarding counters.

--  IPX System-wide Packet Forwarding Counters
--  This group contains the aggregate (device-wide) IPX packet forwarding
--  counters. The byte counters include bytes for the network layer on
--  up, framing is not included.
nwIpxFwdCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregate (system-wide) IPX
        packet and byte counters. Enabled (3) causes these counters to become
        active. Disabled (2) causes these counters to become inactive."
    DEFVAL { enabled }     
    ::= { nwIpxFwdCounters 1 }

nwIpxFwdCtrReset        OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate (system-wide) IPX packet and byte counters.
        Reset (2) resets the IPX aggregate counters to 0.
        nwIpxFwdCtrOperationalTime is also reset to 0."
    DEFVAL { other }      
    ::= { nwIpxFwdCounters 2 }

nwIpxFwdCtrOperationalTime       OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxFwdCtrAdminStatus has been in the current state."
    ::= { nwIpxFwdCounters 3 }

nwIpxFwdCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been received,
        system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 4 }

nwIpxFwdCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been transmitted,
        system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 5 }

nwIpxFwdCtrFwdPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been forwarded,
        system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 6 }

nwIpxFwdCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been
        administratively filtered, system-wide, during
        nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 7 }

nwIpxFwdCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded,
        system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 8 }

nwIpxFwdCtrAddrErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded,
        system-wide, during nwIpxFwdCtrOperationalTime, because of addressing
        errors in the IPX header."
    ::= { nwIpxFwdCounters 9 }

nwIpxFwdCtrLenErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded,
        system-wide, during nwIpxFwdCtrOperationalTime, because an invalid
        packet length is contained in the IPX header."
    ::= { nwIpxFwdCounters 10 }

nwIpxFwdCtrHdrErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded,
        system-wide, during nwIpxFwdCtrOperationalTime, because of an invalid
        IPX header."
    ::= { nwIpxFwdCounters 11 }

nwIpxFwdCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been received, system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 12 }

nwIpxFwdCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been transmitted, system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 13 }

nwIpxFwdCtrFwdBytes     OBJECT-TYPE
    SYNTAX          Counter
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been forwarded, system-wide, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 14 }
nwIpxFwdCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been administratively filtered, system-wide, during
        nwIpxFwd-CtrOperationalTime."
     ::= { nwIpxFwdCounters 15 }

nwIpxFwdCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been discarded, system-wide during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 16 }

nwIpxFwdCtrHostInPkts   OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been successfully
        delivered to the local host, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 17 }

nwIpxFwdCtrHostOutPkts OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been transmitted
        by the local host, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 18 }

nwIpxFwdCtrHostDiscardPkts OBJECT-TYPE
    SYNTAX   Counter
    ACCESS   read-only
    STATUS   mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded
        by the local host, during nwIpxFwdCtrOperationalTime, due to a lack of
        host resources."
    ::= { nwIpxFwdCounters 19 }

nwIpxFwdCtrHostInBytes  OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been received by the local host, during nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 20 }

nwIpxFwdCtrHostOutBytes OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been transmitted by the local host, during 
        nwIpxFwdCtrOperationalTime."
    ::= { nwIpxFwdCounters 21 }

nwIpxFwdCtrHostDiscardBytes OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been discarded by the local host, during nwIpxFwdCtrOperationalTime 
        due to a lack of host resources."
    ::= { nwIpxFwdCounters 22 }


--  IPX Forwarding Interface Table
--  This table contains the managed objects used to set-up and configure
--  each router port.
nwIpxFwdIfTable     OBJECT-TYPE
    SYNTAX  SEQUENCE OF NwIpxFwdIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "This table contains an entry for each router port. This table is
        indexed by nwIpxFwdIfIndex, which indicates the value of MIB2 
        ifIndex, which identifies the router port for which the entry exists."
    ::= { nwIpxFwdIfConfig 1 }

nwIpxFwdIfEntry    OBJECT-TYPE
    SYNTAX  NwIpxFwdIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Each entry specifies the IPX Routing Services configuration for the
        router port for which the entry exists."
    INDEX   { nwIpxFwdIfIndex }
    ::= { nwIpxFwdIfTable 1 }

NwIpxFwdIfEntry ::=
        SEQUENCE {
                nwIpxFwdIfIndex                INTEGER,
                nwIpxFwdIfAdminStatus          INTEGER,
                nwIpxFwdIfOperStatus           INTEGER,
                nwIpxFwdIfOperationalTime   TimeTicks,
                nwIpxFwdIfControl              INTEGER,
                nwIpxFwdIfMtu                  INTEGER,
                nwIpxFwdIfForwarding           INTEGER,
                nwIpxFwdIfFrameType            INTEGER,
                nwIpxFwdIfAclIdentifier        INTEGER,
                nwIpxFwdIfAclStatus            INTEGER,
                nwIpxFwdIfCacheControl         INTEGER,
                nwIpxFwdIfCacheEntries        Counter,
                nwIpxFwdIfCacheHits            Counter,
                nwIpxFwdIfCacheMisses          Counter
                 }

nwIpxFwdIfIndex    OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router 
        port for which the entry exists."
    ::= { nwIpxFwdIfEntry 1 }

nwIpxFwdIfAdminStatus      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of IPX Routing Services on the router
        port for which the entry exists. Enabled (3) causes IPX Routing
        Services to become active. Disabled (2) causes it to become inactive."
    DEFVAL { enabled }   
    ::= { nwIpxFwdIfEntry 2 }

nwIpxFwdIfOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
        }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of IPX Routing Services on
        the router port for which the entry exists. The value of
        nwIpxFwdIfOperStatus indicates any problem with the configuration of 
        IPX Routing Services on the router port. A value of 6 indicates that
        regardless of the state of nwIpxFwdIfAdminStatus IPX Routing Services
        is not operating because of an invalid port-level configuration."
    ::= { nwIpxFwdIfEntry 3 }

nwIpxFwdIfOperationalTime   OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxFwdIfOperStatus has been in its current state."
    ::= { nwIpxFwdIfEntry 4 }

nwIpxFwdIfControl  OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),
                        add(2),
                        delete(3)
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
         "This object does not apply to this protocol. It is a common object
        inherited from the MIB framework used to provide a common management
        interface to all the Cabletron Routing Services protocol-specific MIBs.
        Setting this object has no effect."
    DEFVAL { delete }       
    ::= { nwIpxFwdIfEntry 5 }

nwIpxFwdIfMtu      OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the Maximum Transmission Unit (MTU) for IPX packets on the
        router port for which the entry exists. This includes the IPX header
        and data but does not include framing."
    DEFVAL { 1500 }
    ::= { nwIpxFwdIfEntry 6 }

nwIpxFwdIfForwarding       OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls forwarding of IPX packets on the router port for which the
        entry exists. Enabled (3) causes IPX packets to be forwarded. Disabled
        (2) prevents IPX packets from being forwarded."
    DEFVAL { disabled }
    ::= { nwIpxFwdIfEntry 7 }

nwIpxFwdIfFrameType        OBJECT-TYPE
    SYNTAX         INTEGER    {             --  valid media types
                        other(1),           --  experimental
                        ethernet(2),        --  ethernet
                        snap(3),            --  enet,fddi,and token ring
                        i8022(4),           --  enet, token ring, and fddi
                        novell(6),          --  ethernet and fddi
                        nativewan(8),       --  wan media types
                        encapenet(9),       --  wan media types
                        encapenet8022(10),  --  wan media types
                        encapenetsnap(11),  --  wan media types
                        encapenetnovell(12), -- wan media types
                        encaptr8022(13),    --  wan media types
                        encaptrsnap(14),    --  wan media types
                        encapfddi8022(15),  --  wan media types
                        encapfddisnap(16),  --  wan media types
                        canonical(17)       --  special, tbd
                        }
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the framing type for IPX packets forwarded on the router
        port for which the entry exists.  Some frame types are valid for
        specific media types.  The comments reflect those valid media types."
    DEFVAL { i8022 }
    ::= { nwIpxFwdIfEntry 8 }

nwIpxFwdIfAclIdentifier    OBJECT-TYPE
    SYNTAX         INTEGER    
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the Access Control ID of the Access Control List in effect
        for IPX packets being routed on the router port for which the entry
        exists. A value of 0 indicates that no Access Control List is in
        effect."
    DEFVAL { 0 }
    ::= { nwIpxFwdIfEntry 9 }

nwIpxFwdIfAclStatus        OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of any Access Control List configured for IPX
        traffic on the router port for which the entry exists. Enabled (3)
        applies the Access Control List indicated by the value of
        nwIpxFwdIfAclIdentifier to all IPX traffic being routed to the port.
        Disabled (2) prevents the Access Control List from being applied."
    DEFVAL { disabled }
    ::= { nwIpxFwdIfEntry 10 }

nwIpxFwdIfCacheControl     OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                                disable(2),
                                enable(3)
                        }
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
         "Controls IPX Address caching on the router port for which the entry
        exists. When IPX Address caching is enabled, IPX Addresses used for
        address validation, filtering, and forwarding are stored in the cache.
        This cache is checked first before doing a full route table lookup,
        which speeds up the switching process. Enabled (3) turns on IPX
        Address caching. Disabled (2) turns it off."
    DEFVAL { enable }
    ::= { nwIpxFwdIfEntry 11 }

nwIpxFwdIfCacheEntries     OBJECT-TYPE
        SYNTAX          Counter
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the number of entries in the IPX Address cache on the router port for which the entry exists."
    ::= { nwIpxFwdIfEntry 12 }

nwIpxFwdIfCacheHits        OBJECT-TYPE
    SYNTAX          Counter
    ACCESS          read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the number of times entries in the IPX Adddress cache have
        been used to provide the IPX Address required to validate, filter, or
        forward an IPX packet on the router port."
    ::= { nwIpxFwdIfEntry 13 }
       
nwIpxFwdIfCacheMisses      OBJECT-TYPE
    SYNTAX          Counter
    ACCESS          read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the number of times the IPX Address required to validate,
        filter, or forward an IPX packet on the router port was not found in 
        the IPX Address cache." 
    ::= { nwIpxFwdIfEntry 14 }


--  The IPX Interface Address Table
--  This table contains the managed object used to setup and configure
--  IPX addresses on a per router port basis.
nwIpxAddressTable    OBJECT-TYPE
    SYNTAX  SEQUENCE OF NwIpxAddrEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "This table contains an entry for each Novell network address assigned
        to each router port."
    ::= { nwIpxFwdIfConfig 2 }

nwIpxAddrEntry    OBJECT-TYPE
    SYNTAX  NwIpxAddrEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Each entry specifies the Novell network addressing information for 
        the logical Novll network for which the entry exists."
    INDEX   { nwIpxAddrIfIndex, nwIpxAddrIfAddress }
    ::= { nwIpxAddressTable 1 }

NwIpxAddrEntry ::=
        SEQUENCE {
                nwIpxAddrIfIndex        INTEGER,
                nwIpxAddrIfAddress      IpxAddress,
                nwIpxAddrIfControl      INTEGER,
                nwIpxAddrIfAddrType     INTEGER
                 }

nwIpxAddrIfIndex    OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router 
        port for which the entry exists."
    ::= { nwIpxAddrEntry 1 }

nwIpxAddrIfAddress  OBJECT-TYPE
    SYNTAX  IpxAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "This is the Novell network number assigned to the logical Novell
        network for which the entry exists. The IpxAddress consists of a 
        network number of 4 octets."
    ::= { nwIpxAddrEntry 2 }

nwIpxAddrIfControl  OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),
                        add(2),
                        delete(3)
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Set this object to add or delete this entry from the table."
    DEFVAL { add }
    ::= { nwIpxAddrEntry 3 }

nwIpxAddrIfAddrType  OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),
                        primary(2),
                        secondary(3)
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies whether the Novell network number, nwIpxAddrIfAddress, is 
        the primary or secondary address for the router port."
    DEFVAL { primary }
    ::= { nwIpxAddrEntry 4 }


--  IPX Forwarding Interfaces Counter Table
--  This table contains the objects that specify the packet and byte counters
--  for each configured IPX router port.
nwIpxFwdIfCtrTable         OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxFwdIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains an entry for each router port configured and
        enabled for IPX Routing Services."
    ::= { nwIpxFwdIfCounters 1 }

nwIpxFwdIfCtrEntry         OBJECT-TYPE
    SYNTAX          NwIpxFwdIfCtrEntry
    ACCESS         not-accessible
    STATUS        mandatory
    DESCRIPTION
        "Each entry indicates the current packet and byte count of IPX packets
        on the port for which the entry exists."
    INDEX           { nwIpxFwdIfCtrIfIndex }
    ::= { nwIpxFwdIfCtrTable 1 }

NwIpxFwdIfCtrEntry ::=
        SEQUENCE {
                nwIpxFwdIfCtrIfIndex               INTEGER,
                nwIpxFwdIfCtrAdminStatus           INTEGER,
                nwIpxFwdIfCtrReset                 INTEGER,
                nwIpxFwdIfCtrOperationalTime       TimeTicks,
                nwIpxFwdIfCtrInPkts                Counter,
                nwIpxFwdIfCtrOutPkts               Counter,
                nwIpxFwdIfCtrFwdPkts               Counter,
                nwIpxFwdIfCtrFilteredPkts          Counter,
                nwIpxFwdIfCtrDiscardPkts           Counter,
                nwIpxFwdIfCtrAddrErrPkts           Counter,
                nwIpxFwdIfCtrLenErrPkts            Counter,
                nwIpxFwdIfCtrHdrErrPkts            Counter,
                nwIpxFwdIfCtrInBytes               Counter,
                nwIpxFwdIfCtrOutBytes              Counter,
                nwIpxFwdIfCtrFwdBytes               Counter,
                nwIpxFwdIfCtrFilteredBytes         Counter,
                nwIpxFwdIfCtrDiscardBytes          Counter,
                nwIpxFwdIfCtrHostInPkts            Counter,
                nwIpxFwdIfCtrHostOutPkts           Counter,
                nwIpxFwdIfCtrHostDiscardPkts       Counter,
                nwIpxFwdIfCtrHostInBytes           Counter,
                nwIpxFwdIfCtrHostOutBytes          Counter,
                nwIpxFwdIfCtrHostDiscardBytes      Counter
                 }

nwIpxFwdIfCtrIfIndex       OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 1 }

nwIpxFwdIfCtrAdminStatus   OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the per-port IPX packet and byte
        counters on the router port for which the entry exists. Enabled (3)
        causes these counters to become active. Disabled (2) causes these
        counters to become inactive."
    DEFVAL { enabled }
    ::= { nwIpxFwdIfCtrEntry 2 }

nwIpxFwdIfCtrReset         OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
         "Resets the per-port IPX packet and byte counters on the router port
        for which this entry exists. Reset (2) resets the counters to 0.
        nwIpxFwdIfCtrOperationalTime is also reset to 0."
    DEFVAL { other }
    ::= { nwIpxFwdIfCtrEntry 3 }

nwIpxFwdIfCtrOperationalTime        OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxFwdIfCtrAdminStatus has been in the current state."
    ::= { nwIpxFwdIfCtrEntry 4 }

nwIpxFwdIfCtrInPkts        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been received,
        during nwIpxFwdIfCtrOperationaltime, on the router port for which the
        entry exists."
    ::= { nwIpxFwdIfCtrEntry 5 }

nwIpxFwdIfCtrOutPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been transmitted,
        during nwIpxFwdIfCtrOperationalTime, on the router port for which the
        entry exists."
    ::= { nwIpxFwdIfCtrEntry 6 }

nwIpxFwdIfCtrFwdPkts       OBJECT-TYPE
    SYNTAX          Counter
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been forwarded,
        during nwIpxFwdIfCtrOperationalTime, on the router port for which the
        entry exists."
    ::= { nwIpxFwdIfCtrEntry 7 }

nwIpxFwdIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been
        administratively filtered, during nwIpxFwdIfCtrOperationalTime, on
        the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 8 }

nwIpxFwdIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded
        (dropped), during nwIpxFwdIfCtrOperationalTime, on the router port for
        which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 9 }

nwIpxFwdIfCtrAddrErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded
        because of IPX addressing errors in the IPX header, during
        nwIpxFwdIfCtrOperationalTime, on the router port for which the entry
        exists."
    ::= { nwIpxFwdIfCtrEntry 10 }

nwIpxFwdIfCtrLenErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded
        because an invalid packet length was contained in the IPX header, 
        during nwIpxFwdIfCtrOperationalTime, on the router port for which the
        entry exists."
    ::= { nwIpxFwdIfCtrEntry 11 }

nwIpxFwdIfCtrHdrErrPkts        OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded
        because of an invalid IPX header, during nwIpxFwdIfCtrOperationalTime,
        on the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 12 }

nwIpxFwdIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been received, during nwIpxFwdIfCtrOperationalTime, on the router
        port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 13 }

nwIpxFwdIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have
        been transmitted, during nwIpxFwdIfCtrOperationalTime, on the router
        port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 14 }

nwIpxFwdIfCtrFwdBytes     OBJECT-TYPE
    SYNTAX          Counter
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been forwarded, during nwIpxFwdCtrOperationalTime, on the router port
        for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 15 }

nwIpxFwdIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX                  Counter
    ACCESS                  read-only
    STATUS                  mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets 
        administratively filtered, during nwIpxFwdIfCtrOperationalTime, on
        the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 16 }

nwIpxFwdIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been discarded, during nwIpxFwdIfCtrOperationalTime, on the router 
        port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 17 }

nwIpxFwdIfCtrHostInPkts   OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been successfully
        delivered to the local host, during nwIpxFwdIfCtrOperationalTime, that
        were received on the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 18 }

nwIpxFwdIfCtrHostOutPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been forwarded
        by the local host, during nwIpxFwdIfCtrOperationalTime, on the router
        port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 19 }

nwIpxFwdIfCtrHostDiscardPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX packets that have been discarded 
        by the local host, due to a lack of host resources, during
        nwIpxFwdIfCtrOperationalTime, that were received on the router port
        for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 20 }

nwIpxFwdIfCtrHostInBytes  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have been
        successfully delivered to the local host, during
        nwIpxFwdIfCtrOperationalTime, that were received on the router port for
        which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 21 }

nwIpxFwdIfCtrHostOutBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have been
        transmitted by the local host, during nwIpxFwdIfCtrOperationalTime, on
        the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 22 }

nwIpxFwdIfCtrHostDiscardBytes     OBJECT-TYPE
    SYNTAX                  Counter
    ACCESS                  read-only
    STATUS                  mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX packets that have 
        been discarded by the local host, due to a lack of host resources 
        that were received, during nwIpxFwdIfCtrOperationalTime, that were
        received on the router port for which the entry exists."
    ::= { nwIpxFwdIfCtrEntry 23 }


--  DistanceVector-based Protocols
--  This group contains the managed objects for RIP, IPX DistanceVector based
--  routing.

--  IPX RIP System Configuration Parameters
--  This group contains the objects that pertain to the setup and
--  configuration of the IPX RIP DistanceVector based routing protocol.
 
nwIpxRipAdminStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  shutdown the router
                        enabled(3)            --  startup the router
        }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Sets the administrative state of the IPX-RIP routing protocol
        system-wide. Enabled (3) causes IPX-RIP to become active on all router
        ports configured and enabled for IPX Routing Services. Disabled (2)
        causes IPX-RIP to become inactive."
    DEFVAL { disabled }
    ::= { nwIpxRipConfig 1 }
 
nwIpxRipOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5)     --  start-up in progress
        }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of IPX-RIP system-wide.
        The value of nwIpxRipOperStatus indicates any problem with your 
        IPX-RIP configuration. A value of 6 indicates that regardless of the
        value of nwIpxRipAdminStatus, IPX-RIP is not operating because of an
        invalid configuration."
    ::= { nwIpxRipConfig 2 }
   
nwIpxRipAdminReset      OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "Resets the IPX-RIP routing protocol. Reset (2) forces a system-wide
        restart of IPX-RIP, without a graceful shutdown on any active router
        ports."
    DEFVAL { other }
    ::= { nwIpxRipConfig 3 }
   
nwIpxRipOperationalTime  OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
          "Indicates the elapsed time, in hundredths of a second, that
        nwIpxRipOperStatus has been in its current state."
    ::= { nwIpxRipConfig 4 }
 
nwIpxRipVersion  OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current revision level of the IPX-RIP routing protocol
        firmware, in textual format."
    ::= { nwIpxRipConfig 5 }
 
nwIpxRipStackSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the stack size of the IPX-RIP routing protocol thread. In
        order for a change of this value to take effect, the protocol
        (nwIpxRipAdminReset), IPX Routing Services (nwIpxSysAdminReset), or 
        the device running Routing Services must be reset."
    DEFVAL { 4096 }
    ::= { nwIpxRipConfig 6 }

nwIpxRipThreadPriority OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the run-time execution priority of the IPX-RIP routing
        protocol thread. In order for a change of this value to take effect,
        IPX-RIP (nwIpxRipAdminReset), IPX Routing Services (nwIpxAdminReset),
        or the device running Routing services must be reset."
    DEFVAL { 127 }
    ::= { nwIpxRipConfig 7 }

nwIpxRipDatabaseThreshold OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the run-time maximum number of IPX-RIP entries that can 
        be held in the IPX-RIP route table."
    DEFVAL { 2000 }
    ::= { nwIpxRipConfig 8 }

nwIpxRipAgeOut  OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "Specifies the amount of time, in seconds, that an inactive route
        table entry remains in the IPX-RIP route table before it is aged-out."
    DEFVAL { 180 }
    ::= { nwIpxRipConfig 9 }

nwIpxRipHoldDown        OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the amount of time, in seconds, to wait before removing
        an entry from the route table, after receiving an update indicating
        that the destination has become unreachable. All routers exchanging
        IPX-RIP information must have the same hold down time. The time must
        be long enough to allow all participating routers to receive the same
        update."
    DEFVAL { 120 }
    ::= { nwIpxRipConfig 10 }


--  IPX RIP System (aggregate) Counters
--  This group contains the aggregate (device-wide) IPX RIP packet and
--  byte counters.
nwIpxRipCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregate system-wide IPX-RIP
        packet and byte counters. Enabled (3) causes these counters to become
        active on all router ports. Disabled (2) causes these counters to
        become inactive."
    DEFVAL { enabled }
    ::= { nwIpxRipCounters 1 }

nwIpxRipCtrReset     OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate system-wide IPX-RIP protocol packet and byte
        counters. Reset (2) resets the IPX-RIP aggregate counters to 0.
        nwIpxRipCtrOperationalTime is also reset to 0."
    DEFVAL { other }
    ::= { nwIpxRipCounters 2 }

nwIpxRipCtrOperationalTime       OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
           "Indicates the elapsed time, in hundredths of a second, that
        nwIpxRipCtrAdminStatus has been in the current state."
    ::= { nwIpxRipCounters 3 }

nwIpxRipCtrInPkts                OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP packets that have been
        received, system-wide, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 4 }

nwIpxRipCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
          "Indicates the total number of IPX-RIP packets that have been
        transmitted, system-wide, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 5 }

nwIpxRipCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP packets that have been
        administratively filtered, system-wide, during`
        nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 6 }

nwIpxRipCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
         "Indicates the total number of IPX-RIP packets that have been
        discarded, system-wide, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 7 }

nwIpxRipCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
         "Indicates the total number of bytes in the IPX-RIP packets that 
        have been received, system-wide, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 8 }

nwIpxRipCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP packets that have
        been transmitted, system-wide, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 9 }

nwIpxRipCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP packets that have
        been administratively filtered, system-wide, during
        nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 10 }

nwIpxRipCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP packets that have
        been discarded, during nwIpxRipCtrOperationalTime."
    ::= { nwIpxRipCounters 11 }


-- IPX RIP Interface Table
-- This table contains the managed objects used to setup and configure
-- RIP on a per router port basis.
nwIpxRipIfTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF NwIpxRipIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "This table contains an entry for each router port. Each entry can
        contain different values, allowing the routing protocol configuration
        to vary from router port to router port. This table is indexed by
        nwIpxRipIfIndex, which indicates the value of MIB 2 ifindex, which
        identifies the router port for which each entry exists."
    ::= { nwIpxRipIfConfig 1 }

nwIpxRipIfEntry OBJECT-TYPE
    SYNTAX  NwIpxRipIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Each entry contains the IPX-RIP configuration for the router port for
        which the entry exists."
    INDEX   { nwIpxRipIfIndex }
    ::= { nwIpxRipIfTable 1 }

NwIpxRipIfEntry ::=
        SEQUENCE {
                nwIpxRipIfIndex             INTEGER,
                nwIpxRipIfAdminStatus        INTEGER,
                nwIpxRipIfOperStatus        INTEGER,
                nwIpxRipIfOperationalTime    TimeTicks,
                nwIpxRipIfVersion            INTEGER,
                nwIpxRipIfAdvertisement        INTEGER,
                nwIpxRipIfFloodDelay        INTEGER,
                nwIpxRipIfRequestDelay        INTEGER,
                nwIpxRipIfPriority            INTEGER,
                nwIpxRipIfHelloTimer        INTEGER,
                nwIpxRipIfSplitHorizon      INTEGER,
                nwIpxRipIfPoisonReverse        INTEGER,
                nwIpxRipIfSnooping          INTEGER,
                nwIpxRipIfType                INTEGER,
                nwIpxRipIfXmitCost          INTEGER,
                nwIpxRipIfAclIdentifier     INTEGER,
                nwIpxRipIfAclStatus         INTEGER
                 }

nwIpxRipIfIndex         OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxRipIfEntry 1 }

nwIpxRipIfAdminStatus   OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the IPX-RIP routing protocol on the
        router port for which the entry exists. Enabled (3) causes IPX-RIP to
        become active on the router port. Disabled (2) causes RIP to become
        inactive."
    DEFVAL { disabled }
    ::= { nwIpxRipIfEntry 2 }

nwIpxRipIfOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5)     --  start-up in progress
        }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of the IPX-RIP routing
        protocol on the router port for which the entry exists. The value of
        nwIpxRipIfOperStatus indicates any problem with your IPX-RIP
        configuration on the router port. A value of 6 indicates that
        regardless of the value of nwIpxRipIfAdminStatus, IPX-RIP is not
        operating on the router port because of an invalid configuration."
    ::= { nwIpxRipIfEntry 3 }

nwIpxRipIfOperationalTime        OBJECT-TYPE
    SYNTAX         TimeTicks    
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxRipIfOperStatus has been in its current state."
    ::= { nwIpxRipIfEntry 4 }

nwIpxRipIfVersion       OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the revision level of the IPX-RIP routing protocol in 
        textual format."
    DEFVAL { 1 }
    ::= { nwIpxRipIfEntry 5 }

nwIpxRipIfAdvertisement OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the interval, in seconds, at which IPX-RIP advertises its route
        table on the router port for which the entry exists. Change this value
        to cause IPX-RIP to advertise its route table more or less frequently."
    DEFVAL    { 60 }
    ::= { nwIpxRipIfEntry 6 }

nwIpxRipIfFloodDelay    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the length of time, in seconds, that the IPX-RIP routing
        protocol will wait after discovering that a directly connected route
        has gone down, before flooding updates (triggered updates) on the
        router port for which the entry exists. A value of 0 specifies that
        if a directly connected route goes down, updates will be sent
        immediately."
    DEFVAL { 2 }
    ::= { nwIpxRipIfEntry 7 }

nwIpxRipIfRequestDelay  OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the length of time, in seconds, that the IPX-RIP routing
        protocol will wait after receiving a route request packet before
        sending a response on the router port for which the entry exists. A
        value of 0 specifies that if a route request packet is received on 
        the port, a response will be sent immediately."
    DEFVAL { 6 }
    ::= { nwIpxRipIfEntry 8 }

nwIpxRipIfPriority       OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "This object does not apply to this protocol. It is a common object,
        inherited from the MIB framework used to provide a common management
        interface to all the Cabletron Routing Services protocol-specific MIBs.
        Setting this object has no effect."
    DEFVAL { 1 }
    ::= { nwIpxRipIfEntry 9 }

nwIpxRipIfHelloTimer    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS          mandatory
    DESCRIPTION
        "This object does not apply to this protocol. It is a common object,
        inherited from the MIB framework used to provide a common management
        interface to all the Cabletron Routing Services protocol-specific 
        MIBs. Setting this object has no effect."
    DEFVAL { 10 }  
    ::= { nwIpxRipIfEntry 10 }

nwIpxRipIfSplitHorizon  OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of Split Horizon on the router port for which
        the entry exists. When Split Horizon is enabled, IPX-RIP keeps track
        of which router port route information is received on, and prevents
        information about a route from being sent back out the same router
        port it was received on."
    DEFVAL { enabled }
    ::= { nwIpxRipIfEntry 11 }

nwIpxRipIfPoisonReverse OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
          "Controls the operation of Poison Reverse on the router port for
        which the entry exists. When Poison Reverse is enabled, IPX-RIP
        advertises any downed route as unreachable during the period of time
        that it must wait (nwIpxRipHoldDown) before removing the route from
        the route table."
    DEFVAL { disabled }
    ::= { nwIpxRipIfEntry 12 }

nwIpxRipIfSnooping      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
           "Controls the operation of IPX-RIP Snooping on the router port. When
        RIP Snooping is enabled the IPX-RIP routing protocol operates in
        passive mode, so that it receives route information, builds and
        maintains a route table, but does not advertise or send updates on
        the router port for which the entry exists."
    DEFVAL { disabled }
    ::= { nwIpxRipIfEntry 13 }
                               
nwIpxRipIfType  OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),
                        bma(2),
                        nbma(3)
                 }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates whether the directly connected network segment does or 
        does not support broadcast media access. If broadcast media access is
        supported, IPX-RIP advertisements are sent out one broadcast packet
        per router port. If broadcast media access is not supported, IPX-RIP
        advertisements are sent to each neighbor directly."
    DEFVAL { bma } 
    ::= { nwIpxRipIfEntry 14 }

nwIpxRipIfXmitCost OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
           "This object does not apply to this protocol. It is a common object,
        inherited from the common MIB framework used to provide a common
        management interface to all the Cabletron Routing Services
        protocol-specific MIBs. Setting this object has no effect."
    DEFVAL { 0 }
    ::= { nwIpxRipIfEntry 15 }

nwIpxRipIfAclIdentifier OBJECT-TYPE
    SYNTAX         INTEGER    
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the Access Control ID of the access control list in effect
        for IPX-RIP routing protocol packets on the router port for which the
        entry exists. A value of 0 indicates that there is no access control
        list in effect for IPX-RIP routing protocol packets on the router
        port."
    DEFVAL { 0 } 
    ::= { nwIpxRipIfEntry 16 }

nwIpxRipIfAclStatus     OBJECT-TYPE
    SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of the access control list identified by
        nwIpxRipIfAclIdentifier. Enabled (3) applies the access control list 
        to all IPX-RIP routing protocol packet traffic on the router port for
        which the entry exists. Disabled (2) prevents the access control list
        from being applied. "
    DEFVAL { disabled }
    ::= { nwIpxRipIfEntry 17 }

--  IPX RIP Interface Counters Table
--  This table contains the managed objects for IPX RIP packet and byte
--  counter on a per router port basis.
nwIpxRipIfCtrTable      OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxRipIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains an entry for each router port.This table is
        indexed by nwIpxRipIfCtrIfIndex, which indicates the value of MIB2
        ifindex, which indentifies the router port for which the entry exists."
    ::= { nwIpxRipIfCounters 1 }

nwIpxRipIfCtrEntry      OBJECT-TYPE
    SYNTAX          NwIpxRipIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "Each entry indicates the current packet and byte count of IPX-RIP
        routing protocol packets on the router port for which the entry
        exists."
    INDEX           { nwIpxRipIfCtrIfIndex }
    ::= { nwIpxRipIfCtrTable 1 }

NwIpxRipIfCtrEntry ::=
        SEQUENCE {
                nwIpxRipIfCtrIfIndex            INTEGER,
                nwIpxRipIfCtrAdminStatus        INTEGER,
                nwIpxRipIfCtrReset              INTEGER,
                nwIpxRipIfCtrOperationalTime    TimeTicks,
                nwIpxRipIfCtrInPkts             Counter,
                nwIpxRipIfCtrOutPkts            Counter,
                nwIpxRipIfCtrFilteredPkts       Counter,
                nwIpxRipIfCtrDiscardPkts        Counter,
                nwIpxRipIfCtrInBytes            Counter,
                nwIpxRipIfCtrOutBytes           Counter,
                nwIpxRipIfCtrFilteredBytes      Counter,
                nwIpxRipIfCtrDiscardBytes       Counter
                 }

nwIpxRipIfCtrIfIndex    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 1 }

nwIpxRipIfCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the per-port IPX-RIP packet and 
        byte counters on the router port for which the entry exists. 
        Enabled (3) causes these counters to become active. Disabled (2)
        causes these counters to become inactive."
     DEFVAL { enabled } 
     ::= { nwIpxRipIfCtrEntry 2 }

nwIpxRipIfCtrReset      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the per-port IPX-RIP packet and byte counters on the router
        port for which this entry exists. Reset (2) resets the counters to 0.
        nwIpxRipIfCtrOperationalTime is also reset to 0."
    ::= { nwIpxRipIfCtrEntry 3 }

nwIpxRipIfCtrOperationalTime     OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpRipIfCtrAdminStatus has been in the current state."
    ::= { nwIpxRipIfCtrEntry 4 }

nwIpxRipIfCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP routing protocol packets that
        have been received, during nwIpxRipIfCtrOperationalTime, on the router
        port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 5 }

nwIpxRipIfCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP routing protocol packets that
        have been transmitted, during nwIpxRipIfCtrOperationalTime, on the
        router port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 6 }

nwIpxRipIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP routing protocol packets that
        have been administratively filtered, during
        nwIpxRipIfCtrOperationalTime, on the router port for which the entry
        exists."
    ::= { nwIpxRipIfCtrEntry 7 }

nwIpxRipIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX-RIP routing protocol packets that
        have been discarded, during nwIpxRipIfCtrOperationalTime, that were
        received on the router port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 8 }

nwIpxRipIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP routing protocol
        packets that have been received, during nwIpxRipIfCtrOperationalTime,
        on the router port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 9 }

nwIpxRipIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP routing protocol
        packets that have been transmitted, during
        nwIpxRipIfCtrOperationalTime, on the router port for which the entry
        exists."
    ::= { nwIpxRipIfCtrEntry 10 }

nwIpxRipIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP routing protocol
        packets that have been administratively filtered, during
        nwIpxRipIfCtrOperationalTime, on the router port for which the entry
        exists."
    ::= { nwIpxRipIfCtrEntry 11 }

nwIpxRipIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX-RIP routing protocol
        packets that have been discarded, during nwIpRipIfCtrOperationalTime,
        that were received on the router port for which the entry exists."
    ::= { nwIpxRipIfCtrEntry 12 }


--  IPX RIP Routing Table
--  This table contains the managed objects for IPX RIP route table.
nwIpxRipRouteTable      OBJECT-TYPE
    SYNTAX      SEQUENCE OF NwIpxRipRouteEntry
    ACCESS          not-accessible
    STATUS          mandatory
    DESCRIPTION
        "This table contains the IPX-RIP route table. This table contains an
        entry for each route learned through the IPX-RIP routing protocol. 
        Only the best routes from this table are added to the IPX forwarding
        table to be used for packet switching."
    ::= { nwIpxRipDatabase 1 }

nwIpxRipRouteEntry         OBJECT-TYPE
    SYNTAX      NwIpxRipRouteEntry
    ACCESS          not-accessible
    STATUS          mandatory
    DESCRIPTION
        "Each entry describes the IPX-RIP route to the destination network 
        for which the entry exists."
    INDEX           { nwIpxRipRtNetId, nwIpxRipRtIfIndex, nwIpxRipRtSrcNode }
    ::= { nwIpxRipRouteTable 1 }

NwIpxRipRouteEntry ::=
        SEQUENCE {
                nwIpxRipRtNetId                 IpxAddress,
                nwIpxRipRtIfIndex               INTEGER,
                nwIpxRipRtSrcNode               IpxAddress,
                nwIpxRipRtHops                  INTEGER,
                nwIpxRipRtTicks                 INTEGER,
                nwIpxRipRtAge                   INTEGER,
                nwIpxRipRtType                  INTEGER,
                nwIpxRipRtFlags                 INTEGER
                 }

nwIpxRipRtNetId         OBJECT-TYPE
    SYNTAX          IpxAddress
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is the primary index into the IPX-RIP route table. This number
        indicates the Novell Network Number of the destination for which the
        entry exists. The IpxAddress consists of a network number of 4 octets"
        
    ::= { nwIpxRipRouteEntry 1 }

nwIpxRipRtIfIndex       OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is a secondary index into the IPX-RIP route table. This number
        corresponds to the value of MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxRipRouteEntry 2 }

nwIpxRipRtSrcNode       OBJECT-TYPE
    SYNTAX          IpxAddress
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is a secondary index into the RIP route table. This number
        indicates the MAC-layer address of the source router from which this
        route was learned. A value of 0.0.0.0.0.0 indicates that the source
        is on the network segment directly connected to the router port,
        nwIpxRipRtIfIndex."
    ::= { nwIpxRipRouteEntry 3 }

nwIpxRipRtHops          OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the number of hops required to reach the destination for
        which the entry exists."
    ::= { nwIpxRipRouteEntry 4 }


nwIpxRipRtTicks         OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the amount of time (number of Time Ticks) required to
        reach the destination for which the entry exists."
    ::= { nwIpxRipRouteEntry 5 }

nwIpxRipRtAge           OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the amount of time, in seconds, since an update has been
        received for the route for which the entry exists."
    ::= { nwIpxRipRouteEntry 6 }

nwIpxRipRtType          OBJECT-TYPE
    SYNTAX          INTEGER  {
                                other(1),
                                invalid(2),
                                direct(3),
                                remote(4)
                        }
     ACCESS          read-only
     STATUS          mandatory
     DESCRIPTION
         "Indicates whether the destination network is directly connected
         through the router port specified by nwIpxRipRtIndex, or is 
         indirectly connected through another router, specified by
         nwIpxRipRtSrcNode."
     ::= { nwIpxRipRouteEntry 7 }

nwIpxRipRtFlags         OBJECT-TYPE
    SYNTAX          INTEGER  
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Specifies properties of the IPX-RIP route. The bit mask is as
        follows: source-changed (1), best source (2), local-net (4),
        net-down (8), update-fib-only (16)."
    ::= { nwIpxRipRouteEntry 8 }



--  IPX SAP System Group
--  This group contains the managed object for global, device-wide
--  IPX SAP DistanceVector based routing protocol.

--  IPX SAP System Configuration Parameters
--  This group contains the objects that pertain to the setup and
--  configuration of the IPX SAP DistanceVector based routing protocol.
nwIpxSapAdminStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  shutdown the router
                        enabled(3)            --  startup the router
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Sets the administrative state of the SAP protocol system-wide. 
        Enabled (3) causes SAP to become active on all router ports 
        configured and enabled for IPX routing services. Disabled (2) causes
        the protocol to become inactive."
    DEFVAL { disabled }
    ::= { nwIpxSapConfig 1 }

nwIpxSapOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5)     --  start-up in progress
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of the SAP protocol
        system-wide. The value of nwIpxSapOperStatus indicates any problem 
        with your SAP configuration. A value of 6 indicates that regardless 
        of the value of nwIpxSAPAdminStatus, the SAP protocol is not operating
        because of an invalid configuration."
    ::= { nwIpxSapConfig 2 }

nwIpxSapAdminReset      OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Resets the SAP protocol. Reset (2) forces a system-wide restart of 
        SAP, without a graceful shutdown on any active router ports."
    DEFVAL { other }
    ::= { nwIpxSapConfig 3 }

nwIpxSapOperationalTime  OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
           "Indicates the elapsed time, in hundredths of a second, that
        nwIpxSapOperStatus, has been in its current state."
    ::= { nwIpxSapConfig 4 }

nwIpxSapVersion  OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
          "Indicates the current revision level of the SAP protocol firmware, in
        textual format."
    ::= { nwIpxSapConfig 5 }

nwIpxSapStackSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the stack size of the SAP protocol thread. In order for a
        change to this value to take effect, the protocol (nwIpxSapAdminReset),
        IPX Routing Services (nwIpxSysAdminReset), or the device running
        Routing Services must be reset."
    DEFVAL { 4096 }
    ::= { nwIpxSapConfig 6 }

nwIpxSapThreadPriority OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the run-time execution priority of the SAP protocol 
        thread. In order for a change to this value to take effect, SAP
        (nwIpxSapAdminReset), IPX Routing Services (nwIpxAdminReset), or the
        device running Routing Services must be reset."
    DEFVAL { 127 } 
    ::= { nwIpxSapConfig 7 }

nwIpxSapDatabaseThreshold OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the run-time maximum number of entries that can be held in
        the SAP server table."
    DEFVAL { 2000 } 
    ::= { nwIpxSapConfig 8 }

nwIpxSapAgeOut  OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Specifies the amount of time, in seconds, that an inactive server 
        table entry remains in the SAP server table before it is aged out."
    DEFVAL { 180 }
    ::= { nwIpxSapConfig 9 }

nwIpxSapHoldDown        OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the amount of time, in seconds, to wait before removing an
        entry from the SAP server table, after receiving an update indicating
        that the destination has become unreachable. All routers exchanging
        SAP information must have the same hold down time. The time must be
        long enough to allow all participating routers to receive the same
        update."
    DEFVAL { 120 }
    ::= { nwIpxSapConfig 10 }


--  IPX SAP System (aggregate) Counters
--  This group contains the aggregate (device-wide) IPX SAP packet and
--  byte counters.
nwIpxSapCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregate (system-wide) SAP
        protocol packet and byte counters. Enabled (3) causes these counters
        to become active on all router ports. Disabled (2) causes these 
        counters to become inactive."
    DEFVAL { enabled }
    ::= { nwIpxSapCounters 1 }

nwIpxSapCtrReset     OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate (system-wide) SAP protocol packet and byte
        counters. Reset (2) resets the SAP aggregate counters to 0.
        nwIpxSapCtrOperationalTime is also reset to 0."
    DEFVAL { other }
    ::= { nwIpxSapCounters 2 }

nwIpxSapCtrOperationalTime       OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxSapCtrAdminStatus, has been in the current state."
    ::= { nwIpxSapCounters 3 }

nwIpxSapCtrInPkts       OBJECT-TYPE
    SYNTAX        Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been received,
        system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 4 }

nwIpxSapCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been transmitted,
        system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 5 }

nwIpxSapCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been
        administratively filtered, system-wide, during
        nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 6 }

nwIpxSapCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been discarded,
        system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 7 }

nwIpxSapCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have been
        received, system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 8 }

nwIpxSapCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have
        been transmitted, system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 9 }

nwIpxSapCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have
        been administratively filtered, system-wide, during
        nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 10 }

nwIpxSapCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have 
        been discarded system-wide, during nwIpxSapCtrOperationalTime."
    ::= { nwIpxSapCounters 11 }


--  IPX SAP Interface Table
--  This table contains the managed objects used to setup and configure
--  SAP on a per router port basis.
nwIpxSapIfTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF NwIpxSapIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "This table contains an entry for each router port. Each entry can
        contain different values, allowing the SAP configuration to vary from
        router port to router port. This table is indexed by nwIpxSapIfIndex,
        which indicates the value of MIB 2 ifindex, which identifies the router
        port for which each entry exists."
    ::= { nwIpxSapIfConfig 1 }

nwIpxSapIfEntry OBJECT-TYPE
    SYNTAX  NwIpxSapIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Each entry contains the SAP configuration for the router port for
        which the entry exists."
    INDEX   { nwIpxSapIfIndex }
    ::= { nwIpxSapIfTable 1 }

NwIpxSapIfEntry ::=
        SEQUENCE {
                nwIpxSapIfIndex             INTEGER,
                nwIpxSapIfAdminStatus       INTEGER,
                nwIpxSapIfOperStatus        INTEGER,
                nwIpxSapIfOperationalTime   TimeTicks,
                nwIpxSapIfVersion           INTEGER,
                nwIpxSapIfAdvertisement     INTEGER,
                nwIpxSapIfFloodDelay        INTEGER,
                nwIpxSapIfRequestDelay      INTEGER,
                nwIpxSapIfPriority          INTEGER,
                nwIpxSapIfHelloTimer        INTEGER,
                nwIpxSapIfSplitHorizon      INTEGER,
                nwIpxSapIfPoisonReverse     INTEGER,
                nwIpxSapIfSnooping          INTEGER,
                nwIpxSapIfType              INTEGER,
                nwIpxSapIfXmitCost          INTEGER,
                nwIpxSapIfAclIdentifier     INTEGER,
                nwIpxSapIfAclStatus         INTEGER
                 }

nwIpxSapIfIndex         OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxSapIfEntry 1 }

nwIpxSapIfAdminStatus   OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the SAP protocol on the router port
        for which the entry exists. Enabled (3) causes SAP to become active
        on the router port. Disabled (2) causes SAP to become inactive."
    DEFVAL { disabled }
    ::= { nwIpxSapIfEntry 2 }

nwIpxSapIfOperStatus     OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5)     --  start-up in progress
        }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of the SAP protocol on the
        router port for which the entry exists. The value of
        nwIpxSapIfOperStatus indicates any problem with your SAP configuration
        on the router port. A value of 6 indicates that regardless of the
        value of nwIpxSapIfAdminStatus. SAP is not operating because of an
        invalid configuration."
    ::= { nwIpxSapIfEntry 3 }

nwIpxSapIfOperationalTime        OBJECT-TYPE
    SYNTAX         TimeTicks    
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxSapIfOperStatus has been in its current state."
    ::= { nwIpxSapIfEntry 4 }

nwIpxSapIfVersion       OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the revision level of the SAP protocol in textual format."
    DEFVAL { 1 }
    ::= { nwIpxSapIfEntry 5 }

nwIpxSapIfAdvertisement OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the interval, in seconds, at which SAP advertises its server
        table on the router port for which the entry exists. Change this value
        to cause SAP to advertise its server table more or less frequently."
    DEFVAL    { 60 }
    ::= { nwIpxSapIfEntry 6 }

nwIpxSapIfFloodDelay    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the length of time, in seconds, that the SAP protocol will
        wait after discovering that a directly connected route has gone down,
        before flooding updates (triggered updates) on the router port for
        which the entry exists. A value of 0 specifies that if a directly
        connected route goes down, updates should be sent immediately ."
    DEFVAL { 2 }
    ::= { nwIpxSapIfEntry 7 }

nwIpxSapIfRequestDelay  OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the length of time, in seconds, that the SAP protocol will
        wait after receiving a server request packet, before sending a
        response on the router port for which the entry exists. A value of 0
        specifies that if a server request packet is received on the port, a
        response will be sent immediately."
    DEFVAL { 0 }
    ::= { nwIpxSapIfEntry 8 }

nwIpxSapIfPriority       OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "This object does not apply to this protocol. It is a common object,
        inherited from the MIB framework used to provide a management 
        interface to all the Cabletron Routing Services protocol-specific
        MIBs. Setting this object has no effect."
    DEFVAL { 1 }
    ::= { nwIpxSapIfEntry 9 }

nwIpxSapIfHelloTimer    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-write
    STATUS          mandatory
    DESCRIPTION
        "This object does not apply to this protocol. It is a common object,
        inherited from the MIB framework used to provide a management
        interface to all the Cabletron Routing Services protocol-specific
        MIBs.Setting this object has no effect."
    DEFVAL { 10 }
    ::= { nwIpxSapIfEntry 10 }

nwIpxSapIfSplitHorizon  OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of Split Horizon on the router port for which
        the entry exists. When Split Horizon is enabled, SAP keeps track of
        which router port information is received on, and prevents information
        about a server from being sent back out the same router port it was
        received on."
    DEFVAL { enabled }
    ::= { nwIpxSapIfEntry 11 }

nwIpxSapIfPoisonReverse OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of Poison Reverse on the router port for
        which the entry exists. When Poison Reverse is enabled, SAP
        advertises any downed server as unreachable during the period of time
        that it must wait (nwIpxSapIfHoldDown) before removing the server
        from the server table."
    DEFVAL { disabled }
    ::= { nwIpxSapIfEntry 12 }

nwIpxSapIfSnooping      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of SAP Snooping on the router port. When SAP
        Snooping is enabled SAP operates in passive mode, so it receives
        service information, builds and maintains a server table, but does
        not advertise or send updates on the router port for which the entry
        exists. Enabled (3) turns on SAP Snooping. Disabled (2) turns off SAP
        Snooping."
    DEFVAL { disabled }
    ::= { nwIpxSapIfEntry 13 }
                                
nwIpxSapIfType  OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),
                        bma(2),
                        nbma(3)
                 }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates whether the directly connected network segment does or
        does not support broadcast media access. If broadcast media access is
        supported, SAP advertisements are sent out, one broadcast packet per
        router port. If broadcast media access is not supported, SAP
        advertisements are sent to each neighbor router directly."
    DEFVAL { bma }
    ::= { nwIpxSapIfEntry 14 }

nwIpxSapIfXmitCost OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "This object does not apply to this protocol. It is a common object,
        inherited from the MIB framework used to provide a common management
        interface to all the Cabletron Routing Services protocol-specific MIBs.
        Setting this object has no effect."
    DEFVAL { 0 }
    ::= { nwIpxSapIfEntry 15 }

nwIpxSapIfAclIdentifier OBJECT-TYPE
    SYNTAX         INTEGER    
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the Access Control List ID of the access control list in
        effect for SAP protocol packets on the router port for which the entry
        exists. A value of 0 indicates that there is no access control list 
        in effect for SAP protocol packets on the router port for which the
        entry exists."
    DEFVAL { 0 }
    ::= { nwIpxSapIfEntry 16 }

nwIpxSapIfAclStatus     OBJECT-TYPE
    SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Controls the operation of the access control list identified by
        nwIpxSapIfAclIdentifier. Enabled (3) causes the access control list
        to be applied to all SAP protocol packet traffic on the router port 
        for which the entry exists. Disabled (2) prevents the access control
        list from being applied."
    DEFVAL { disabled }
    ::= { nwIpxSapIfEntry 17 }

--  IPX SAP Interface Counters Table
--  This table contains the managed objects for IPX SAP packet and byte
--  counter on a per router port basis.
nwIpxSapIfCtrTable      OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxSapIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains an entry for each router port. This table is
        indexed by nwIpxSapIfCtrIfIndex which indicates the value of MIB2
        ifindex, which indentifies the router port for which the entry 
        exists."
    ::= { nwIpxSapIfCounters 1 }

nwIpxSapIfCtrEntry      OBJECT-TYPE
    SYNTAX          NwIpxSapIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "Each entry indicates the current packet and byte count of SAP 
        protocol packets on the router port for which the entry exists."
    INDEX           { nwIpxSapIfCtrIfIndex }
    ::= { nwIpxSapIfCtrTable 1 }

NwIpxSapIfCtrEntry ::=
        SEQUENCE {
                nwIpxSapIfCtrIfIndex            INTEGER,
                nwIpxSapIfCtrAdminStatus        INTEGER,
                nwIpxSapIfCtrReset              INTEGER,
                nwIpxSapIfCtrOperationalTime    TimeTicks,
                nwIpxSapIfCtrInPkts             Counter,
                nwIpxSapIfCtrOutPkts            Counter,
                nwIpxSapIfCtrFilteredPkts       Counter,
                nwIpxSapIfCtrDiscardPkts        Counter,
                nwIpxSapIfCtrInBytes            Counter,
                nwIpxSapIfCtrOutBytes           Counter,
                nwIpxSapIfCtrFilteredBytes      Counter,
                nwIpxSapIfCtrDiscardBytes       Counter
                 }

nwIpxSapIfCtrIfIndex    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the value of the MIB 2 ifindex, which identifies the router
        port for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 1 }

nwIpxSapIfCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the per-port SAP packet and byte
        counters on the router port for which this entry exists. Enabled (3)
        causes these counters to become active. Disabled (2) causes these
        counters to become inactive."
    DEFVAL { enabled }
    ::= { nwIpxSapIfCtrEntry 2 }

nwIpxSapIfCtrReset      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the per-port SAP packet and byte counters on the router port 
        for which the entry exists. Reset (2) resets the counters to 0.
        nwIpxSapIfCtrOperationalTime is also reset to 0."
    DEFVAL { other }
    ::= { nwIpxSapIfCtrEntry 3 }

nwIpxSapIfCtrOperationalTime     OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxSapIfCtrAdminStatus has been in the current state."
    ::= { nwIpxSapIfCtrEntry 4 }

nwIpxSapIfCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP protocol packets that have been
        received, during nwIpxSapIfCtrOperationalTime, on the router port for
        which the entry exists."
    ::= { nwIpxSapIfCtrEntry 5 }

nwIpxSapIfCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been transmitted,
        during nwIpxSapIfCtrOperationalTime, on the router port for which the
        entry exists."
    ::= { nwIpxSapIfCtrEntry 6 }

nwIpxSapIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been
        administratively filtered, during nwIpxSapIfCtrOperationalTime, on 
        the router port for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 7 }

nwIpxSapIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of SAP packets that have been discarded,
        during nwIpxSapIfCtrOperationalTime, that were received on the router
        port for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 8 }

nwIpxSapIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have 
        been received, during nwIpxSapIfCtrOperationalTime, on the router port
        for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 9 }

nwIpxSapIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have been
        transmitted, during nwIpxSapIfCtrOperationalTime, on the router port
        for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 10 }

nwIpxSapIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have been
        administratively filtered, during nwIpxSapIfCtrOperationalTime, on the
        router port for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 11 }

nwIpxSapIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the SAP packets that have
        been discarded, during nwIpxSapIfCtrOperationalTime, that were 
        received on the router port for which the entry exists."
    ::= { nwIpxSapIfCtrEntry 12 }

--  IPX SAP Server table Table
--  This table contains the managed objects for IPX SAP route table.
nwIpxSapServerIfTable      OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxSapServerIfEntry
    ACCESS          not-accessible
    STATUS          mandatory
    DESCRIPTION
        "The table contains the SAP server table. This table contains an entry
        for each service learned of through the SAP protocol."
    ::= { nwIpxSapServerTable 1 }

nwIpxSapServerIfEntry         OBJECT-TYPE
    SYNTAX      NwIpxSapServerIfEntry
    ACCESS          not-accessible
    STATUS          mandatory
    DESCRIPTION
        "Each entry contains the SAP route information for the Novell server
        and router port for which the entry exists."
    INDEX    { nwIpxSapServerIfNetId, nwIpxSapServerIfNode,
                   nwIpxSapServerIfSocket, nwIpxSapServerIfServiceType,
                   nwIpxSapServerIfIfNum, nwIpxSapServerIfSrcNode }
    ::= { nwIpxSapServerIfTable 1 }

NwIpxSapServerIfEntry ::=
        SEQUENCE {
                nwIpxSapServerIfNetId                 IpxAddress,
                nwIpxSapServerIfNode                  OCTET STRING,
                nwIpxSapServerIfSocket                OCTET STRING,
                nwIpxSapServerIfServiceType           INTEGER,
                nwIpxSapServerIfIfNum                 INTEGER,
                nwIpxSapServerIfSrcNode               OCTET STRING,
                nwIpxSapServerIfName                  OCTET STRING,
                nwIpxSapServerIfHops                  INTEGER,
                nwIpxSapServerIfAge                   INTEGER,
                nwIpxSapServerIfType                  INTEGER,
                nwIpxSapServerIfFlags                 INTEGER
                 }
nwIpxSapServerIfNetId       OBJECT-TYPE
    SYNTAX          IpxAddress
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is the primary index into the SAP server table. This number
        corresponds to the Novell Network Number of the server offering the
        service.  The network number consists of 4 octets."
    ::= { nwIpxSapServerIfEntry 1 }

nwIpxSapServerIfNode       OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is a secondary index into the SAP Server Table. This is the
        MAC-layer address represented as an octetstring of the service
        offering the server for which the entry exists, represented as an
        octet string."
    ::= { nwIpxSapServerIfEntry 2 }

nwIpxSapServerIfSocket     OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is a secondary index into the SAP Server Table. This is the
        socket number of the server application for which the entry exists."
    ::= { nwIpxSapServerIfEntry 3 }

nwIpxSapServerIfServiceType       OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is a secondary index into the SAP Server Table. This is the
        service type of the server application for which the entry exists."
    ::= { nwIpxSapServerIfEntry 4 }

nwIpxSapServerIfIfNum       OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the value of MIB 2 ifindex, which identifies the router
        port through which the service for which the entry exits is available."
    ::= { nwIpxSapServerIfEntry 5 }

nwIpxSapServerIfSrcNode     OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is the MAC-layer address of the neighbor router from which the
        service was learned about."
    ::= { nwIpxSapServerIfEntry 6 }

nwIpxSapServerIfName       OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "This is the name of the server offering the service for which the
        entry exists."
    ::= { nwIpxSapServerIfEntry 7 }

nwIpxSapServerIfHops          OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the number of hops required to reach the server offering
        the service for which the entry exists."
    ::= { nwIpxSapServerIfEntry 8 }

nwIpxSapServerIfAge           OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates the amount of time since a SAP update was last received
        for the server and service for which the entry exits."
    ::= { nwIpxSapServerIfEntry 9 }

nwIpxSapServerIfType          OBJECT-TYPE
    SYNTAX          INTEGER  {
                                other(1),
                                invalid(2),
                                direct(3),
                                remote(4)
                        }
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Indicates whether the server is on a network that is directly
        connected through the router port for which the entry exists, or is
        indirectly connected through another router specified by the value of
        nwIpxSapServerIfSrcNode."
    ::= { nwIpxSapServerIfEntry 10 }

nwIpxSapServerIfFlags         OBJECT-TYPE
    SYNTAX          INTEGER  
    ACCESS          read-only
    STATUS          mandatory
    DESCRIPTION
        "Specifies properties of the SAP service for which the entry exist.
        The bit mask is as follows: source-changed (1), best-source (2), not
        used (4), net-down (8), not used (16)."
    ::= { nwIpxSapServerIfEntry 11 }


--  IPX Forward Information Base (FIB) Table
--  This table contains the managed objects for the forwarding table of the
--  IPX router.  This table is built from entries in the IPX routing table(s)
--  and reflects the routes that are considered the best routes to forward on.
nwIpxFibTable           OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxFibEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains an entry describing each route being used to
        forward IPX traffic to each destination Novell network and node."
    ::= { nwIpxFib 1 }

nwIpxFibEntry           OBJECT-TYPE
    SYNTAX          NwIpxFibEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "Each entry describes the route to the destination Novell network and
        node for which the entry exists."
    INDEX   { nwIpxFibNetId }
    ::= { nwIpxFibTable 1 }

NwIpxFibEntry ::=
        SEQUENCE {
                nwIpxFibNetId           IpxAddress,
                nwIpxFibHops            INTEGER,
                nwIpxFibTimeTicks       TimeTicks,
                nwIpxFibNextHopIf       INTEGER,
                nwIpxFibNextHopNet      OCTET STRING,
                nwIpxFibNextHopNode     MacAddress,
                nwIpxFibRouteType       INTEGER
                 }

nwIpxFibNetId           OBJECT-TYPE
    SYNTAX         IpxAddress
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Specifies the Novell Network Number of the destination for which the
        entry exists.  The IpxAddress consists of four octets"
    ::= { nwIpxFibEntry 1 }

nwIpxFibHops            OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the number of hops required to reach the destination for
        which the entry exists. It is considered as metric 1."
    DEFVAL { 0 }
    ::= { nwIpxFibEntry 2 }

nwIpxFibTimeTicks       OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the amount of time, indicated by the number of TimeTicks,
        required for a packet to reach the destination network for which the
        entry exists. It is considered as metric 2."
    DEFVAL { 0 }
    ::= { nwIpxFibEntry 3 }

nwIpxFibNextHopIf       OBJECT-TYPE
    SYNTAX          INTEGER
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the router port through which the next hop node is 
        available. Packets destined for the network specified by the value of
        nwIpxFibNetId will be forwarded on this port."
    ::= { nwIpxFibEntry 4 }

nwIpxFibNextHopNet      OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the Novell Network Number portion of the fully formed next
        hop IPX Address of the next hop node."
    ::= { nwIpxFibEntry 5 }

nwIpxFibNextHopNode     OBJECT-TYPE
    SYNTAX          MacAddress
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the node portion of the fully formed next hop IPX Address."
    ::= { nwIpxFibEntry 6 }

nwIpxFibRouteType       OBJECT-TYPE
    SYNTAX          INTEGER  {
                other(1),
                                invalid(2),
                                direct(3),
                                remote(4)
                        }
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Indicates the status of the route. A value of 3 indicates that the
        destination is on the network segment that is directly connected to
        the router port identified by nwIpxFibNextHopIf. A value of 4 indicates
        that the destination is on an indirectly connected network segment,
        which is reachable through the next hop router indicated by the value
        of nwIpxFibNextHopNodeId. A value of 2 indicates that the route is
        invalid."
    DEFVAL { direct }
    ::= { nwIpxFibEntry 7 }


--  IPX Access Control List Table
--  This table contains the managed objects for the Access Control Lists
--  within the IPX Router.  Access Control Lists allow configuration of
--  restricted access to networks and protocols reachable thru the IPX
--  Router device.  Access Control Lists can be defined with these
nwIpxAclValidEntries  OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the number of valid entries that exist in the access control
        list table."
    ::= { nwIpxAccessControl 1 }

nwIpxAclTable           OBJECT-TYPE
    SYNTAX          SEQUENCE OF NwIpxAclEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains the access control list information for IPX
        traffic. This table contains entries, each of which allows packet
        forwarding between source/destination pairs to be permitted or denied.
        The list is identified by the Access Control List ID. Each list may
        contain multiple entries ordered by sequence number. When a particular
        access control list is searched, it is searched in sequence number
        order and the first match found ends the search. If no match if found,
        access defaults to permitted."
    ::= { nwIpxAccessControl 2 }

nwIpxAclEntry           OBJECT-TYPE
    SYNTAX          NwIpxAclEntry
    ACCESS          not-accessible
    STATUS        mandatory
    DESCRIPTION
        "Each entry contains IPX source/destination access information."
    INDEX           { nwIpxAclIdentifier, nwIpxAclSequence }
    ::= { nwIpxAclTable 1 }

NwIpxAclEntry ::=
        SEQUENCE {
                nwIpxAclIdentifier           INTEGER,
                nwIpxAclSequence             INTEGER,
                nwIpxAclPermission           INTEGER,
                nwIpxAclMatches              Counter,
                nwIpxAclDestNetNum           OCTET STRING,
                nwIpxAclDestNode             OCTET STRING,
                nwIpxAclDestSocket             OCTET STRING,
                nwIpxAclSrcNetNum            OCTET STRING,
                nwIpxAclSrcNode              OCTET STRING,
                nwIpxAclSrcSocket             OCTET STRING
                 }

nwIpxAclIdentifier      OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "This is the primary (major) index into the IPX access control list
        table. This value identifies the access control list by a unique
        identifier (at least 1) arbitrarily assigned by the user. All entries
        that have the same value for nwIpxAclIdentifier belong to the same
        access control list."
    ::= { nwIpxAclEntry 1 }

nwIpxAclSequence        OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "This is the secondary (minor) index into the IPX access control list
        table. This number corresponds to a sequence number used to order
        multiple entries within the same access control list."
    ::= { nwIpxAclEntry 2 }

nwIpxAclPermission      OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            invalid(2),
                            permit(3),
                            deny(4),
                            permit-bidirectional(5),
                            deny-bidirectional(6)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies whether access is allowed or denied between the source and
        destination address pair. Note that source and destination are
        interchangeable when bi-directional control is selected. To remove an
        existing entry set nwIpxAclPermission to invalid (2). Invalid entries
        disappear after reboot."
    DEFVAL { permit }
    ::= { nwIpxAclEntry 3 }

nwIpxAclMatches         OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the number of matches on this entry that have resulted in
        the permit/deny access restriction being applied as part of the
        forwarding process."
    ::= { nwIpxAclEntry 4 }

nwIpxAclDestNetNum     OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the destination Novell Network Number used to compare for
        matches on the access control list. A 0 value is a wildcard which
        matches any Novell Network Number."        
    ::= { nwIpxAclEntry 5 }

nwIpxAclDestNode        OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the MAC-layer address of the destination node (represented
        as an octet string), used to compare for matches on the access control
        list. A value 0 is a wildcard, which matches any node."
    ::= { nwIpxAclEntry 6 }

nwIpxAclDestSocket    OBJECT-TYPE
    SYNTAX        OCTET STRING
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the socket number of the destination socket used to compare
        for matches on the access control list. A 0 value is a wildcard 
        matching any socket."
    ::= { nwIpxAclEntry 7 }

nwIpxAclSrcNetNum       OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the Novell Network Number of the source Novell Network used
        to compare for matches on the access control list. A 0 value is a
        wildcard matching any Novell Network Number."
    ::= { nwIpxAclEntry 8 }

nwIpxAclSrcNode         OBJECT-TYPE
    SYNTAX          OCTET STRING
    ACCESS          read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the MAC-layer address of the source node (represented as an
         octet string), used to compare for matches on the Access Control
         List. A 0 value is a wildcard matching any node."
    ::= { nwIpxAclEntry 9 }

nwIpxAclSrcSocket    OBJECT-TYPE
    SYNTAX        OCTET STRING
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Specifies the socket number of the source socket to compare for
        matches on the Access Control List. A 0 value is a wildcard matching
        any socket."
    ::= { nwIpxAclEntry 10 }

--  IPX Redirector Group

--  IPX NetBIOS System Group
--  In order for NetBIOS to function, an IPX routing service is provided
--  which allows NetBIOS traffic to be flooded out all router ports with
--  NetBIOS enabled.

nwIpxNetBIOSAdminStatus    OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                                disabled(2),
                                enabled(3)
                        }
    ACCESS          read-write
    STATUS          mandatory
    DESCRIPTION
        "Sets the administrative state of the NetBIOS Broadcast Redirector,
        system-wide. Enabled (3) causes the NetBios Broadcast Redirector to
        become active on any router port configured and enabled for IPX
        Routing Services. Disabled (2) causes the NetBIOS Broadcast Redirector
        to perform a graceful shut-down on any active IPX router port."
    DEFVAL { disabled }
    ::= { nwIpxNetBIOSConfig 1 }

nwIpxNetBIOSOperStatus    OBJECT-TYPE
    SYNTAX  INTEGER {
                      other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current operating condition of the NetBIOS Broadcast
        Redirector, system-wide. "
     ::= { nwIpxNetBIOSConfig 2 }

nwIpxNetBIOSAdminReset    OBJECT-TYPE
    SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
               }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Resets the NetBIOS Broadcast Redirector, system-wide. Reset (2)
        forces a restart of the NetBIOS Broadcast Redirector without a 
        graceful shut-down on any active router port and without effecting any
        other router application."
    DEFVAL { other }
    ::= { nwIpxNetBIOSConfig 3 }

nwIpxNetBIOSOperationalTime     OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundredths of a second, that
        nwIpxNetBiosOperStatus has been in the current state."
    ::= { nwIpxNetBIOSConfig 4 }

nwIpxNetBIOSVersion    OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Indicates the current revision level of the NetBIOS Broadcast
        Redirector firmware, in textual format."
    ::= { nwIpxNetBIOSConfig 5 }

--    IPX NetBIOS System (aggregate) Counters
--    This group contains the aggregate (device-wide) IPX NetBIOS packet
--    and byte counters.
nwIpxNetBIOSCtrAdminStatus  OBJECT-TYPE
    SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregate (system-wide) NetBIOS
        broadcast packet and byte counters. Enabled (3) causes these counters
        to become active on all router port. Disabled (2) causes these 
        counters to become inactive."
    ::= { nwIpxNetBIOSCounters 1 }

nwIpxNetBIOSCtrReset     OBJECT-TYPE
    SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate (system-wide) NetBIOS broadcast packet and byte
        counters. Reset (2) resets the NetBIOS broadcast aggregate counters
        to 0. nwIpxNetBIOSCtrOperationalTime is also reset to 0."
    ::= { nwIpxNetBIOSCounters 2 }

nwIpxNetBIOSCtrOperationalTime       OBJECT-TYPE
    SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the elapsed time, in hundreds of a second, that the
        nwIpxNetBIOSCtrAdminStatus has been in the current state."
    ::= { nwIpxNetBIOSCounters 3 }

nwIpxNetBIOSCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS broadcast packets that have 
        been received, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 4 }

nwIpxNetBIOSCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
          "Indicates the total number of NetBIOS broadcast packets that have
        been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 5 }

nwIpxNetBIOSCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS broadcast packets that have
        been administratively filtered, system-wide, during
        nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 6 }

nwIpxNetBIOSCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS broadcast packets that have
        been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 7 }

nwIpxNetBIOSCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
         "Indicates the total number of bytes in the NetBIOS packets that have
        been received, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 8 }

nwIpxNetBIOSCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
        been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 9 }

nwIpxNetBIOSCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
        been administratively filtered, system-wide, during
        nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 10 }

nwIpxNetBIOSCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
        been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime."
    ::= { nwIpxNetBIOSCounters 11 }

--  IPX NetBIOS Interface Table
--    This table contains the managed objects used to setup and configure
--    NetBIOS on a per router port basis.
nwIpxNetBIOSIfTable     OBJECT-TYPE
    SYNTAX  SEQUENCE OF NwIpxNetBIOSIfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "This table contains an entry for each router port. Each entry can
        contain different values, allowing the NetBIOS Broadcast Redirector
        configuration to vary from router port to router port. This table is
        indexed by nwIpxNetBIOSIfIndex, which indicates the value of MIB 2
        ifindex, which identifies the router port for which the entry exists."    
    ::= { nwIpxNetBIOSIfConfig 1 }

nwIpxNetBIOSIfEntry    OBJECT-TYPE
        SYNTAX  NwIpxNetBIOSIfEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "Each entry contains the IPX NetBIOS broadcasting configuration for
             the router port for which the entry exists."                                INDEX   { nwIpxNetBIOSIfIndex }
        ::= { nwIpxNetBIOSIfTable 1 }

NwIpxNetBIOSIfEntry ::=
        SEQUENCE {
                nwIpxNetBIOSIfIndex                INTEGER,
                nwIpxNetBIOSIfAdminStatus        INTEGER,
                nwIpxNetBIOSIfOperStatus        INTEGER,
                nwIpxNetBIOSIfOperationalTime    TimeTicks
                 }

nwIpxNetBIOSIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Indicates the value in MIB 2 ifindex, which identifies the router
             port for which the entry exists."
    ::= { nwIpxNetBIOSIfEntry 1 }

nwIpxNetBIOSIfAdminStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the administrative state of IPX NetBIOS broadcasting on the
             router port for which the entry exists. Enabled (3) causes this
             router port to become active. Disabled (2) causes it to become
             inactive."
    DEFVAL { disabled }
    ::= { nwIpxNetBIOSIfEntry 2 }

nwIpxNetBIOSIfOperStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current operating condition of IPX NetBIOS
             broadcasting on the IPX router port for which the entry exists."
            ::= { nwIpxNetBIOSIfEntry 3 }

nwIpxNetBIOSIfOperationalTime    OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the elapsed time, in hundredths of a second, that IPX
             NetBIOS broadcasting, nwIpxNetBIOSIfOperStatus, has been in its
             current state on the router port for which the entry exists."
::= { nwIpxNetBIOSIfEntry 4 }

--    IPX NetBIOS Interface Counters Table
--    This table contains the managed objects for IPX NetBIOS packet and 
--    byte counter on a per router port basis

nwIpxNetBIOSIfCtrTable      OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwIpxNetBIOSIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains the IPX NetBIOS packet and byte counters for each
         router port on this device."
        ::= { nwIpxNetBIOSIfCounters 1 }

nwIpxNetBIOSIfCtrEntry      OBJECT-TYPE
    SYNTAX      NwIpxNetBIOSIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the NetBIOS Interface Counter Table.
         This number corresponds to the index into the MIB 2 Interface Table
         which describes the router port for which this entry exists."
         INDEX           { nwIpxNetBIOSIfCtrIfIndex }
         ::= { nwIpxNetBIOSIfCtrTable 1 }

NwIpxNetBIOSIfCtrEntry ::=
        SEQUENCE {
                nwIpxNetBIOSIfCtrIfIndex            INTEGER,
                nwIpxNetBIOSIfCtrAdminStatus        INTEGER,
                nwIpxNetBIOSIfCtrReset              INTEGER,
                nwIpxNetBIOSIfCtrOperationalTime    TimeTicks,
                nwIpxNetBIOSIfCtrInPkts             Counter,
                nwIpxNetBIOSIfCtrOutPkts            Counter,
                nwIpxNetBIOSIfCtrFilteredPkts       Counter,
                nwIpxNetBIOSIfCtrDiscardPkts        Counter,
                nwIpxNetBIOSIfCtrInBytes            Counter,
                nwIpxNetBIOSIfCtrOutBytes           Counter,
                nwIpxNetBIOSIfCtrFilteredBytes      Counter,
                nwIpxNetBIOSIfCtrDiscardBytes       Counter
                 }

nwIpxNetBIOSIfCtrIfIndex    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the IPX NetBIOS Interface Counter Table.
         This number correspoonds to the index into the MIB 2 Interface Table
         which describes the router port for which the entry exists."
        ::= { nwIpxNetBIOSIfCtrEntry 1 }

nwIpxNetBIOSIfCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the IPX NetBIOS packet and bytes
         counters on the IPX router port for which the entry exists. Enabled (3)
         causes these counters to become active on the configured NetBIOS router
         port. Disabled (2) causes thes counters to become inactive on the
         configured NetBIOS router port."
        ::= { nwIpxNetBIOSIfCtrEntry 2 }

nwIpxNetBIOSIfCtrReset      OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the NetBIOS packet and bvyte counters on the router port for
         which the entry exists. Reset (2) resets the interface-specific
         counters to 0. nwIpxNetBIOSIfCtrOperationalTime is also reset to 0."
        ::= { nwIpxNetBIOSIfCtrEntry 3 }

nwIpxNetBIOSIfCtrOperationalTime     OBJECT-TYPE
        SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the amount of time, in hundredths of a second, that the
         interface-specific NetBIOS packet and byte counters have been active on
         the router port for which the entry exists."
        ::= { nwIpxNetBIOSIfCtrEntry 4 }

nwIpxNetBIOSIfCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS packets that have been recieved,
         on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 5 }

nwIpxNetBIOSIfCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS packets that have been
         transmitted, on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationallTime."
        ::= { nwIpxNetBIOSIfCtrEntry 6 }

nwIpxNetBIOSIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS packets that have been
         administratively filtered, on the router port for which the entry
         exists, during nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 7 }

nwIpxNetBIOSIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of NetBIOS packets that have been discarded,
         on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 8 }

nwIpxNetBIOSIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
         been recieved, on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 9 }

nwIpxNetBIOSIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
         been transmitted, on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 10 }

nwIpxNetBIOSIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
         been administratively filtered, that were recieved on the router port
         for which the entry exists during nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 11 }

nwIpxNetBIOSIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the NetBIOS packets that have
         been discarded, on the router port for which the entry exists, during
         nwIpxNetBIOSIfCtrOperationalTime."
        ::= { nwIpxNetBIOSIfCtrEntry 12 }


--  IPX Broadcast System Group

--  IPX Broadcast support allows broadcast packets that would normally be
--  delivered to the host to also be switched out the proper router port
--  if that router port has broadcast enabled. The router port is determined
--  by the destination network number in the broadcast packet.

nwIpxBcastAdminStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  shutdown the router
                        enabled(3)            --  startup the router
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Sets the administrative state of IPX Broadcast. Enabled (3) casuses
             IPX Broadcast to become active on any configured IPX router port.
             Disabled (2) causes IPX Broadcast to perform a graceful shutdown on
             any active IPX router ports."
    DEFVAL { disabled }
    ::= { nwIpxBroadcastConfig 1 }

nwIpxBcastOperStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current operating condition of the IPX Broadcast."
    ::= { nwIpxBroadcastConfig 2 }

nwIpxBcastAdminReset    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Resets the IPX Broadcast. Reset (2) will force a restart of the IPX
             Broadcast without a graceful shutdown on any active IPX router port,
             without effecting any other router applications."
        DEFVAL { other }
    ::= { nwIpxBroadcastConfig 3 }

nwIpxBcastOperationalTime    OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the amount of time, in hundredths of a second, that IPX
             Broadcast has been in its current operational state."
    ::= { nwIpxBroadcastConfig 4 }

nwIpxBcastVersion    OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current revision level of IPX Broadcast."
    ::= { nwIpxBroadcastConfig 5 }

--    IPX Broadcast System (aggregate) Counters
--    This group contains the aggregate (device-wide) IPX Broadcast packet
--    and byte counters.
nwIpxBcastCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregate (device-wide) Broadcast packet and byte counters. enable (3) causes these counters
 to become active on any router port running Broadcast. disabled (2) 
causes these counters to become inactive on all router port
        running Broadcast."
        ::= { nwIpxBroadcastCounters 1 }

nwIpxBcastCtrReset     OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate (device-wide) IPX Broadcast packet and byte
         counters. Reset (2) resets the IPX Broadcast aggregate counters to 0.
         nwIpxBcasstCtrOperationalTime is also reset to 0."
        ::= { nwIpxBroadcastCounters 2 }

nwIpxBcastCtrOperationalTime       OBJECT-TYPE
        SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
          "Indicates the amount of time, in hundredths of a second, that the
         aggregate (device-wide) IPX Broadcast packet and byte counters have been
         in the current administrative state."
        ::= { nwIpxBroadcastCounters 3 }

nwIpxBcastCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         received, device-wide, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 4 }

nwIpxBcastCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
          "Indicates the total number of IPX Broadcast packets that have been
         transmitted, device-wide, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 5 }

nwIpxBcastCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         administaratively filtered, device-wide, during
         nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 6 }

nwIpxBcastCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         discarded, device-wide, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 7 }

nwIpxBcastCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
         "Indicates the total number of IPX Broadcast packets that have been
         recieved, device-wide, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 8 }

nwIpxBcastCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         transmitted, device-wide, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 9 }

nwIpxBcastCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Broadcast packets that
         have been administratively filtered, device-wide, during
         nwIpxBcastOperationalTime."
        ::= { nwIpxBroadcastCounters 10 }

nwIpxBcastCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
                "Indicates the total number of bytes in the Broadcast packets that
         have been discarded, during nwIpxBcastCtrOperationalTime."
        ::= { nwIpxBroadcastCounters 11 }


--  IPX Broadcast Interface Table
--    This table contains the managed objects used to setup and configure
--    Broadcast on a per router port basis.
nwIpxBcastIfTable     OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwIpxBcastIfEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "This table contains an entry for each router port configured for the
             IPX distance-vector based routing protocol. Each entry can contain
             different values, allowing the routing protocol configuration to
             vary from router port to router port. This table is indexed by
             nwIpxBcastIfIndex, which indicates the value of MIB 2 ifindex, which
             identifies the router port for which the entry exists."
        ::= { nwIpxBroadcastIfConfig 1 }

nwIpxBcastIfEntry    OBJECT-TYPE
        SYNTAX  NwIpxBcastIfEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "Specifies the IPX Broadcast configuration information for the
             logical IPX interface for which this entry exists."
    INDEX   { nwIpxBcastIfIndex }
        ::= { nwIpxBcastIfTable 1 }

NwIpxBcastIfEntry ::=
        SEQUENCE {
                nwIpxBcastIfIndex            INTEGER,
                nwIpxBcastIfAdminStatus        INTEGER,
                nwIpxBcastIfOperStatus        INTEGER,
                nwIpxBcastIfOperationalTime    TimeTicks
                 }

nwIpxBcastIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This index corresponds to the primary index into the MIB 2 Interface
             Table, which describes the router port for which the entry exists."
    ::= { nwIpxBcastIfEntry 1 }

nwIpxBcastIfAdminStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the administrative state of the IPX Broadcast on the router
             port for which the entry exists. Enabled (2) causes IPX Broadcast on
             this router port to become active. Disabled (2) causes IPX Broadcast
             to become inactive."
        DEFVAL { disabled }
    ::= { nwIpxBcastIfEntry 2 }

nwIpxBcastIfOperStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current operating condition of the IPX Broadcast on
             the router port for which the entry exists."
    ::= { nwIpxBcastIfEntry 3 }

nwIpxBcastIfOperationalTime    OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the elapsed time, in hundredths of a second, that
             nwIPXBcastIfOperStatus has been in its current state."
    ::= { nwIpxBcastIfEntry 4 }

--    IPX Broadcast Interface Counters Table
--    This table contains the managed objects for IPX Broadcast packet and 
--    byte counter on a per router port basis.
nwIpxBcastIfCtrTable      OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwIpxBcastIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains the IPX Broadcast packet and byte counters for each
         router port on this device."
        ::= { nwIpxBroadcastIfCounters 1 }

nwIpxBcastIfCtrEntry      OBJECT-TYPE
        SYNTAX          NwIpxBcastIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the Broadcast Interface Counter Table.
         This number corresponds to the index into the MIB 2 Interface Table
         which describes the router port for which the entry exists."
        INDEX           { nwIpxBcastIfCtrIfIndex }
        ::= { nwIpxBcastIfCtrTable 1 }

NwIpxBcastIfCtrEntry ::=
        SEQUENCE {
                nwIpxBcastIfCtrIfIndex            INTEGER,
                nwIpxBcastIfCtrAdminStatus        INTEGER,
                nwIpxBcastIfCtrReset              INTEGER,
                nwIpxBcastIfCtrOperationalTime    TimeTicks,
                nwIpxBcastIfCtrInPkts             Counter,
                nwIpxBcastIfCtrOutPkts            Counter,
                nwIpxBcastIfCtrFilteredPkts       Counter,
                nwIpxBcastIfCtrDiscardPkts        Counter,
                nwIpxBcastIfCtrInBytes            Counter,
                nwIpxBcastIfCtrOutBytes           Counter,
                nwIpxBcastIfCtrFilteredBytes      Counter,
                nwIpxBcastIfCtrDiscardBytes       Counter
                 }

nwIpxBcastIfCtrIfIndex    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the IPX Broadcast Interface Counter
         Table. This number corresponds to the index into the MIB 2 Interface
         Table which describes the router port for which the entry exists."
        ::= { nwIpxBcastIfCtrEntry 1 }

nwIpxBcastIfCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the IPX Broadcast packet and byte
         counters on the router port for which the entry exists. Enabled (3)
         causes these counters to become acive on the configured IPX Broadcast
         router port. Disabled (2) causes these counters to become inactive on
         the configured IPX Broadcast router port."
        ::= { nwIpxBcastIfCtrEntry 2 }

nwIpxBcastIfCtrReset      OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the IPX Broadcast packet and byte counters on the router port for
         which the entry exists. Reset (2) resets the interface-specific counters
         to 0. nwIpxBcastIfCtrOperationalTime is also reset to 0."
        ::= { nwIpxBcastIfCtrEntry 3 }

nwIpxBcastIfCtrOperationalTime     OBJECT-TYPE
        SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the amount of time, in hundredths of a second, that the
         interface-specific IPX Broadcast packet and byte counters have been in
         the current administrative state on the router port for which the entry
         exists."
        ::= { nwIpxBcastIfCtrEntry 4 }

nwIpxBcastIfCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         recieved, on the router port for which the entry exists, during
         nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 5 }

nwIpxBcastIfCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of Broadcast packets that have been
         transmitted, on the router port for which the entry existsl, during
         nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 6 }

nwIpxBcastIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Broadcast packets that have been
         administratively filtered, on the router port for which the entry
         exists, during nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 7 }

nwIpxBcastIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
                "Indicates the total number of Broadcast packets that have been dis-
        carded, on the router port for which the entry exists, during 
        nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 8 }

nwIpxBcastIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Broadcast packets that
         have been recieved, on the router port for which the entry exists,
         during nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 9 }

nwIpxBcastIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Broadcast packets that
         have been transmitted, on the router port for which the entry exists,
         during nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 10 }

nwIpxBcastIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Broadcast packets that
         have been administratively filtered on the router port for which the
         entry exists during nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 11 }

nwIpxBcastIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Broadcast packets that
         have been discarded on the router port for which the entry exists,
         during nwIpxBcastIfCtrOperationalTime."
        ::= { nwIpxBcastIfCtrEntry 12 }


--  IPX Echo System Group
--  Echo messages provide the ability to check for host reachability and
--  network connectivity.  If the router receives an ECHO message, it
--  sends and ECHO reply to the source of the ECHO message.

nwIpxEchoAdminStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  shutdown the router
                        enabled(3)            --  startup the router
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Sets the administrative state of the IPX Echo. Enabled (3) causes
             IPX ECHO to become active on any configured IPX router ports.
             Disabled (2) causes IPX Echo to perform a graceful shutdown on any
             active IPX router port."
        DEFVAL { disabled }
    ::= { nwIpxEchoConfig 1 }

nwIpxEchoOperStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the operating condition of IPX Echo."
    ::= { nwIpxEchoConfig 2 }

nwIpxEchoAdminReset    OBJECT-TYPE
        SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        reset(2)              --  force a reset
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Resets IPX Echo. Reset (2) will force a restart of IPX Echo without
             a graceful shutdown on any active IPX router port, without effecting
             any other router applications."
::= { nwIpxEchoConfig 3 }

nwIpxEchoOperationalTime    OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the amount of time, in hundredths of a second, that IPX
             Echo has been in its current administrative state,
             nwIpxEchoOperStatus."
::= { nwIpxEchoConfig 4 }

nwIpxEchoVersion    OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current revision level of IPX Echo firmware."
    ::= { nwIpxEchoConfig 5 }

--    IPX Echo System (aggregate) Counters
--    This group contains the aggregate (device-wide) IPX Echo packet 
--    and byte counters.
nwIpxEchoCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the aggregae (device-wide) IPX Echo
         packet and byte counters. Enabled (3) causes these counters to become
         active on any router port running IPX Echo. Disabled (2) causes these
         counters to become inactive on all router ports."
        ::= { nwIpxEchoCounters 1 }

nwIpxEchoCtrReset     OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the aggregate (device-wide) IPX Echo packet and byte counters.
         Reset (2) resets the IPX Echo aggregate counters to 0.
         nwIpxEchoCtrOperationalTime is also reset to 0."
        ::= { nwIpxEchoCounters 2 }

nwIpxEchoCtrOperationalTime       OBJECT-TYPE
        SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the amount of time, in hundredths of a second, that the
         aggreagate (device-wide) IPX Echo packet and byte counters have been in
         the current administrative state."
        ::= { nwIpxEchoCounters 3 }

nwIpxEchoCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been recieved,
         device-wide, during nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 4 }

nwIpxEchoCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
          "Indicates the total number of IPX Echo packets that have been
         transmitted, device-wide, during nwIpxEchoCtrOperationalTIme."
        ::= { nwIpxEchoCounters 5 }

nwIpxEchoCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been
         administratively filtered, device-wide, during
         nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 6 }

nwIpxEchoCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been discarded,
         device-wide, during nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 7 }

nwIpxEchoCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
         "Indicates the total number of IPX Echo packets that have been recieved,
         device-wide, during nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 8 }

nwIpxEchoCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been
         transmitted, device-wide, during nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 9 }

nwIpxEchoCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been
         administratively filtered, device-wide, during
         nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 10 }

nwIpxEchoSCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
                "Indicates the total number of bytes in the Echo packets that
         have been discarded, during nwIpxEchoCtrOperationalTime."
        ::= { nwIpxEchoCounters 11 }


--  IPX Echo Interface Table
--    This table contains the managed objects used to setup and configure
--    Echo on a per router port basis.
nwIpxEchoIfTable     OBJECT-TYPE
        SYNTAX  SEQUENCE OF NwIpxEchoIfEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "This table contains an entry for each router port configured for IPX
             Echo. Each entry can contain different values, allowing the routing
             protocol configuration to vary from router port to router port. This
             table is indexed by nwIpxEchoIfIndex, which indicates the value of
             MIB 2 ifindex, which identifies the router port for which the entry
             exists."    
        ::= { nwIpxEchoIfConfig 1 }

nwIpxEchoIfEntry    OBJECT-TYPE
        SYNTAX  NwIpxEchoIfEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "Specifies the IPX Echo information for the logical IPX interface for
             which the entry exists."
    INDEX   { nwIpxEchoIfIndex }
        ::= { nwIpxEchoIfTable 1 }

NwIpxEchoIfEntry ::=
        SEQUENCE {
                nwIpxEchoIfIndex            INTEGER,
                nwIpxEchoIfAdminStatus        INTEGER,
                nwIpxEchoIfOperStatus        INTEGER,
                nwIpxEchoIfOperationalTime    TimeTicks
                  }

nwIpxEchoIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This index corresponds to the primary index into the MIB 2 ifTable,
             which describes the router port for which the entry exists."
    ::= { nwIpxEchoIfEntry 1 }

nwIpxEchoIfAdminStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            disabled(2),
                            enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the administrative state of IPX Echo on the router port for
             which the entry exists. Enabled (2) causes this router port to
             become active. Disabled (3) causes this router port to become
             inactive."
        DEFVAL { enabled }
    ::= { nwIpxEchoIfEntry 2 }

nwIpxEchoIfOperStatus    OBJECT-TYPE
            SYNTAX  INTEGER {
                        other(1),             --  none of the following
                        disabled(2),          --  not running
                        enabled(3),           --  running
                        pending-disable(4),   --  shut-down in progress
                        pending-enable(5),    --  start-up in progress
                        invalid-config(6)     --  not running,invalid config
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the current operating condition of IPX Echo on the router
             port for which the entry exists."
    ::= { nwIpxEchoIfEntry 3 }

nwIpxEchoIfOperationalTime     OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Indicates the elapsed time, in hundredths of a second, that
             nwIpxEchoIfAdminStatus has been in its current state."
    ::= { nwIpxEchoIfEntry 4 }

--    IPX Echo Interface Counters Table
--    This table contains the managed objects for IPX Echo packet and 
--    byte counter on a per router port basis.
nwIpxEchoIfCtrTable      OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwIpxEchoIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This table contains the IPX Echo packet and byte counters for each
         router port on this device."
        ::= { nwIpxEchoIfCounters 1 }

nwIpxEchoIfCtrEntry      OBJECT-TYPE
        SYNTAX          NwIpxEchoIfCtrEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the Echo Interface Counter Table. This
         number corresponds to the index into the MIB 2 Interface Table which
         describes the router port for which the entry exists."
        INDEX           { nwIpxEchoIfCtrIfIndex }
        ::= { nwIpxEchoIfCtrTable 1 }

NwIpxEchoIfCtrEntry ::=
        SEQUENCE {
                nwIpxEchoIfCtrIfIndex            INTEGER,
                nwIpxEchoIfCtrAdminStatus        INTEGER,
                nwIpxEchoIfCtrReset              INTEGER,
                nwIpxEchoIfCtrOperationalTime    TimeTicks,
                nwIpxEchoIfCtrInPkts             Counter,
                nwIpxEchoIfCtrOutPkts            Counter,
                nwIpxEchoIfCtrFilteredPkts       Counter,
                nwIpxEchoIfCtrDiscardPkts        Counter,
                nwIpxEchoIfCtrInBytes            Counter,
                nwIpxEchoIfCtrOutBytes           Counter,
                nwIpxEchoIfCtrFilteredBytes      Counter,
                nwIpxEchoIfCtrDiscardBytes       Counter
                 }

nwIpxEchoIfCtrIfIndex    OBJECT-TYPE
    SYNTAX         INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "This is the primary index into the IPX Echo Interface Counter Table.
         This number corresponds to the index into the MIB 2 Interfcace Table
         which describes the router port for which the entry exists."
        ::= { nwIpxEchoIfCtrEntry 1 }

nwIpxEchoIfCtrAdminStatus  OBJECT-TYPE
        SYNTAX          INTEGER {
                other(1),
                disabled(2),
                enabled(3)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Sets the administrative state of the IPX Echo packet and byte counters
         on the IPX router port for which the entry exists. Enabled (3) causes
         these counters to become active on the router port configured for IPX
         Echo. Disabled (2) causes these counters to become inactive on the
         configured IPX Echo router port."
        ::= { nwIpxEchoIfCtrEntry 2 }

nwIpxEchoIfCtrReset      OBJECT-TYPE
        SYNTAX          INTEGER {
                            other(1),
                            reset(2)
                        }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
        "Resets the IPX Echo packet andbyte counters on the router port for which
         the entryexists. Reset (2) resets the interface-specific counters to 0.
         nwIpxEchoIfCtrOperationalTime is also reset to 0."
        ::= { nwIpxEchoIfCtrEntry 3 }

nwIpxEchoIfCtrOperationalTime     OBJECT-TYPE
        SYNTAX          TimeTicks
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the amount of time, in hundredths of a second, that the
         interface-specific IPX Echo packet and byte counters have been in the
         current administrative state on the router port for which the entry
         exists."
        ::= { nwIpxEchoIfCtrEntry 4 }

nwIpxEchoIfCtrInPkts       OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been recieved,
         on the router port for which the entry exists, during
         nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 5 }

nwIpxEchoIfCtrOutPkts      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been
         transmitted, on the router port for which the entry exists, during
         nwIpxEchoIfCrOperationalTIme."
        ::= { nwIpxEchoIfCtrEntry 6 }

nwIpxEchoIfCtrFilteredPkts OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been
         administratively filtered, on the router port for which the entry
         exists, during nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 7 }

nwIpxEchoIfCtrDiscardPkts  OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of IPX Echo packets that have been discaded,
         on the router port for which the entry exists, during
         nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 8 }

nwIpxEchoIfCtrInBytes      OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Echo packets that have
         been recieved, on the router port for which the entry exists, during
         nwIpxEchoIfCtrOpeationalTime."
        ::= { nwIpxEchoIfCtrEntry 9 }

nwIpxEchoIfCtrOutBytes     OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Echo packets that have
         been transmitted, on the router port for which the entry exists, during
         nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 10 }

nwIpxEchoIfCtrFilteredBytes        OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Echo packets that have
         been administratively filtered and recieved on the router port for which
         the entry exists, during nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 11 }

nwIpxEchoIfCtrDiscardBytes OBJECT-TYPE
    SYNTAX         Counter
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
        "Indicates the total number of bytes in the IPX Echo packets that have
         been discarded, that were recieved on the router port for which the
         entry exists, during nwIpxEchoIfCtrOperationalTime."
        ::= { nwIpxEchoIfCtrEntry 12 }

--
--  IPX Hosts-to-Media Table 

--  This table provides a mapping between IPX Network Protocol
--  addresses and their corresponding circuit identifiers (if
--  applicable), port numbers, and framing.


nwIpxHostMapTable       OBJECT-TYPE
    SYNTAX           SEQUENCE OF NwIpxHostMapEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
                "The Ipx Address translation table used for mapping 
         an IPX address to a circuit identifier (if applicable), 
         corresponding port number, and framing type."
        ::= { nwIpxHostsToMedia 1 }

nwIpxHostMapEntry     OBJECT-TYPE
     SYNTAX         NwIpxHostMapEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
                "Each entry contains one IpxAddress to circuit
        equivalence. Also provided is the framing required to
        converse with this host, and the corresponding logical 
        port number."
        INDEX   { nwIpxHostMapIfIndex, nwIpxHostMapIpxAddr }
        ::= { nwIpxHostMapTable 1 }

 NwIpxHostMapEntry ::=
        SEQUENCE {
                nwIpxHostMapIfIndex     INTEGER,
                nwIpxHostMapIpxAddr     IpxAddress,
                nwIpxHostMapPhysAddr    PhysAddress,
                nwIpxHostMapType        INTEGER,   
                nwIpxHostMapCircuitID   INTEGER,
                nwIpxHostMapFraming     INTEGER,   
                nwIpxHostMapPortNumber  INTEGER
                }

nwIpxHostMapIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This is the primary (major) index into the Ipx HostMap 
        table. This number corresponds to the index into the MIB-2 
        Interfaces Group which describes the IPX router port for which
        the entry exists."
        ::= { nwIpxHostMapEntry 1 }
 
nwIpxHostMapIpxAddr    OBJECT-TYPE
        SYNTAX  IpxAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The IpxAddress of the host on the corresponding interface
        and circuit (if applicable).  The IpxAddress consists of a network
        number of 4 octets followed by 6 octets of node identifier."
        ::= { nwIpxHostMapEntry 2 }

nwIpxHostMapPhysAddr    OBJECT-TYPE
        SYNTAX  PhysAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The media-dependent 'physical' address. The value of
              this object is 0 for entries indicating native-wan(8)
              framing."
        ::= { nwIpxHostMapEntry 3 }

nwIpxHostMapType        OBJECT-TYPE
        SYNTAX  INTEGER {
            other(1),
            invalid(2),
            dynamic(3),
            static(4),
            inactive(5)
        }    
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                 "Setting this object to the value invalid(2) has 
        the effect of invalidating the corresponding entry in the
        nwIpxHostMapTable.  That is, it effectively dissasociates the
        circuit and/or interface identified with said entry from the  
        mapping identified with said entry.  It is an implementation-
        specific matter as to whether the agent removes an invalidated 
        entry from the table.  Accordingly, management stations must be 
        prepared to receive tabular information from agents that 
        corresponds to entries not currently in use.  Proper inter-
        pretation of such entries requires examination of the relevant
        wIpxHostMapType object."

        ::= { nwIpxHostMapEntry 4 }

nwIpxHostMapCircuitID    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The identifier for the virtual circuit present on the 
        interface. On an interface configured for Frame Relay,
        this number is the DLCI for the IPX Address at the end of
        the circuit. For non-WAN interfaces, the value of this
        object is zero."
        ::= { nwIpxHostMapEntry 5 }

nwIpxHostMapFraming    OBJECT-TYPE
        SYNTAX INTEGER {                    --  valid media types
                        other(1),           --  experimental
                        ethernet(2),        --  ethernet
                        snap(3),            --  enet,fddi,and token ring
                        i8022(4),           --  enet, token ring, and fddi
                        novell(6),          --  ethernet and fddi
                        nativewan(8),       --  wan media types
                        encapenet(9),       --  wan media types
                        encapenet8022(10),  --  wan media types
                        encapenetsnap(11),  --  wan media types
                        encapenetnovell(12), -- wan media types
                        encaptr8022(13),    --  wan media types
                        encaptrsnap(14),    --  wan media types
                        encapfddi8022(15),  --  wan media types
                        encapfddisnap(16),  --  wan media types
                        canonical(17)       --  special, tbd
                        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specifies the framing type required to converse with the
         host for which this entry exists."
        ::= { nwIpxHostMapEntry 6 }

nwIpxHostMapPortNumber    OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The unique value for the logical port number. It's value
        ranges between 1 and a maximum value which is dependent on both
        the number of configured interfaces in the system and the number
        of circuits present on those interfaces which are of WAN type."
        ::= { nwIpxHostMapEntry 7 }




--  IPX Event Group
nwIpxEventAdminStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                                enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the administrative state of IPX event logging. Enabled (3)
         causes the event log to become active. Disabled (2) causes the event log
         to become inactive."
        DEFVAL { disabled }
        ::= { nwIpxEventLogConfig 1 }

nwIpxEventMaxEntries     OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the maximum size of the event log table. When the table size
             exceeds the maximum, the first entry is deleted until the size of
             the table does not exceed the maximum."
        DEFVAL { 100 }
        ::= { nwIpxEventLogConfig 2 }

nwIpxEventTraceAll OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                disabled(2),
                                enabled(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Sets the administrative state of the event log. Enabled (3) allows
             logging of all event types on all router ports from all protocols
             and components. Disabled (2) causes the filter table to specify
             which events to log."
    DEFVAL { enabled }
        ::= { nwIpxEventLogConfig 3 }


--  Event Log Filter Table
--  The Event Log Filter Table contains the managed objects used to set-up
--  and configure log entries.

nwIpxEventFilterTable            OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwIpxEventFilterEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
            "This table contains an entry for each event filter configured for
             IPX Routing Services events."
        ::= { nwIpxEventLogFilterTable 1 }

nwIpxEventFilterEntry            OBJECT-TYPE
        SYNTAX          NwIpxEventFilterEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
            "Each entry describes an event filter which defines a particular type
             of event to be logged to the event log. The nwIpxEventProtocol
             refers to the instance used in the nwRtgProtocolTable and
             nwComponentTable specified by the Cabletron Routing Services MIB,
             and identifies the protocol to which the entry applies."
        INDEX   { nwIpxEventFltrProtocol, nwIpxEventFltrIfNum }
        ::= { nwIpxEventFilterTable 1 }

NwIpxEventFilterEntry ::=
        SEQUENCE {
                nwIpxEventFltrProtocol   INTEGER,
                nwIpxEventFltrIfNum      INTEGER,
                nwIpxEventFltrControl    INTEGER,
                nwIpxEventFltrType       INTEGER,
                nwIpxEventFltrSeverity   INTEGER,
                nwIpxEventFltrAction     INTEGER
                 }

nwIpxEventFltrProtocol   OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Specifies the routing protocol involved in the event for which the
             event filter exists."
        ::= { nwIpxEventFilterEntry 1 }

nwIpxEventFltrIfNum      OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Specifies the router port involved in the event for which the event
             filter exists."
        ::= { nwIpxEventFilterEntry 2 }

nwIpxEventFltrControl    OBJECT-TYPE
        SYNTAX          INTEGER {
                                other(1),
                                delete(2),
                                add(3)
                        }
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION
            "Set this value to 3 to add the event filter to the Event Filter
             Table. Set this value to 2 to delete the event filter from the Event
             Filter Table."
         DEFVAL { add }
        ::= { nwIpxEventFilterEntry 3 }

nwIpxEventFltrType        OBJECT-TYPE
        SYNTAX      INTEGER {
                            misc(1),
                            timer(2),
                            rcv(4),
                            xmit(8),
                            event(16),
                            error(32)
            }
        ACCESS      read-write
        STATUS      mandatory
        DESCRIPTION
            "This 6 bit mask specifies the types of events to be logged. By
             default all 6 bits are set to 1, indicating that all types of events
             will be logged. Setting any bit to 0 removes an event type from this
             field and prevents that type of event from being logged. Adding
             event types to this field will enable those types of events to be
             logged."
        DEFVAL { misc }
    ::= { nwIpxEventFilterEntry 4 }

nwIpxEventFltrSeverity   OBJECT-TYPE
        SYNTAX      INTEGER {
                             highest(1),
                             highmed(2),
                             highlow(3)
            }
        ACCESS      read-write
        STATUS      mandatory
        DESCRIPTION
            "This object controls the amount of logging by ignoring events of
             lower priority than specified by this filter value. The highest
             value will ignore all events except those of the highest severity.
             `Highmed' will log all events highest priority through lowest.
             `Highlow' will log all events highest priority through lowest. The
             `highmed' severity is the default setting."
        DEFVAL { highest }
    ::= { nwIpxEventFilterEntry 5 }

nwIpxEventFltrAction OBJECT-TYPE
    SYNTAX      INTEGER {
                        log(1),
                        trap(2),
                        log-trap(3)
            }
    ACCESS      read-write
    STATUS      mandatory
    DESCRIPTION
        "This field specifies how the events are to be logged. Logging to the
         `log' stores the events in the event log table. Logging to `trap' sends
         events out through the trap mechanism."
        DEFVAL { log }
    ::= { nwIpxEventFilterEntry 6 }

--  Event Log Table
--  The Event Log Table contains the logged events.

nwIpxEventTable          OBJECT-TYPE
        SYNTAX          SEQUENCE OF NwIpxEventEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
            "This table contains an entry for each event that has been logged."
        ::= { nwIpxEventLogTable 1 }

nwIpxEventEntry          OBJECT-TYPE
        SYNTAX          NwIpxEventEntry
        ACCESS          not-accessible
        STATUS          mandatory
        DESCRIPTION
            "Each entry contains the information about an event that has been
             logged to the event table."
        INDEX           { nwIpxEventNumber }
        ::= { nwIpxEventTable 1 }

NwIpxEventEntry ::=
        SEQUENCE {
                nwIpxEventNumber         INTEGER,
                nwIpxEventTime           TimeTicks,
                nwIpxEventType           INTEGER,
                nwIpxEventSeverity       INTEGER,
                nwIpxEventProtocol       INTEGER,
                nwIpxEventIfNum          INTEGER,
                nwIpxEventTextString     OCTET STRING
                 }

nwIpxEventNumber         OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "An ordinal value assigned to the event for which the entry exists.
             nwIpxEventNumber is assigned so that each event in the event log can
             be uniquely identified by the value of nwIpxEventNumber."
        ::= { nwIpxEventEntry 1 }

nwIpxEventTime           OBJECT-TYPE
        SYNTAX          TimeTicks
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the time at which the event was logged to the event log."
        ::= { nwIpxEventEntry 2 }

nwIpxEventType           OBJECT-TYPE
        SYNTAX          INTEGER {
                                misc(1),
                                timer(2),
                                rcv(4),
                                xmit(8),
                                event(16),
                                error(32)
                        }
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the type of event that was logged."
        ::= { nwIpxEventEntry 3 }

nwIpxEventSeverity               OBJECT-TYPE
        SYNTAX          INTEGER {
                                highest(1),
                                highmed(2),
                                highlow(3)
                        }
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the priority that was assigned to this type event."
        ::= { nwIpxEventEntry 4 }

nwIpxEventProtocol               OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the routing protocol that was involved in this event."
        ::= { nwIpxEventEntry 5 }

nwIpxEventIfNum          OBJECT-TYPE
        SYNTAX          INTEGER
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Indicates the router port that was involved in the event."
        ::= { nwIpxEventEntry 6 }

nwIpxEventTextString     OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION
            "Contains the actual text string that was logged."
        ::= { nwIpxEventEntry 7 }

END