CTRON-SFPS-CONN-MIB device MIB details by Enterasys Networks Inc
CTRON-SFPS-CONN-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-SFPS-CONN-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-SFPS-CONN-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-SFPS-CONN-MIB DEFINITIONS ::= BEGIN -- sfps-conn-mib.txt -- Revision: 0.0.02 -- -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise specific Fast Packet Switching Services MIB. -- -- This module will be extended, as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright October 93 Cabletron Systems -- IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB -- enterprises, -- IpAddress, -- Counter, Gauge, TimeTicks FROM RFC1155-SMI -- These Objects are defined in the file sfps-inc.mib.txt sfpsServiceCenter FROM CTRON-SFPS-INCLUDE-MIB; -- Textual Conventions HexInteger ::= INTEGER -- display this integer in hex format -- CONNECT sfpsServiceCenterConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpsServiceCenterConnectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table gives connect semantics to call processing." ::= { sfpsServiceCenter 4 } sfpsServiceCenterConnectEntry OBJECT-TYPE SYNTAX SfpsServiceCenterConnectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the configuration of the Connect Entry." INDEX { sfpsServiceCenterConnectAddress } ::= { sfpsServiceCenterConnectTable 1 } SfpsServiceCenterConnectEntry ::= SEQUENCE { sfpsServiceCenterConnectAddress HexInteger, sfpsServiceCenterConnectMetric INTEGER, sfpsServiceCenterConnectName DisplayString, sfpsServiceCenterConnectOperStatus INTEGER, sfpsServiceCenterConnectAdminStatus INTEGER, sfpsServiceCenterConnectStatusTime TimeTicks, sfpsServiceCenterConnectRequests INTEGER, sfpsServiceCenterConnectResponses INTEGER } sfpsServiceCenterConnectAddress OBJECT-TYPE SYNTAX HexInteger ACCESS read-only STATUS mandatory DESCRIPTION "Server hash, part of instance key." ::= { sfpsServiceCenterConnectEntry 1 } sfpsServiceCenterConnectMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines order servers are called low to high." ::= { sfpsServiceCenterConnectEntry 2 } sfpsServiceCenterConnectName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Server name." ::= { sfpsServiceCenterConnectEntry 3 } sfpsServiceCenterConnectOperStatus OBJECT-TYPE SYNTAX INTEGER { kStatusRunning(1), -- all is well kStatusHalted(2), -- admin disabled kStatusPending(3), -- Trying to run, not there yet kStatusFaulted(4), -- Internal error, never will recover kStatusNotStarted(5) -- Not fully started yet } ACCESS read-only STATUS mandatory DESCRIPTION "Operational state of entry." ::= { sfpsServiceCenterConnectEntry 4 } sfpsServiceCenterConnectAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- Not running or stopped disable(2), -- Please stop enable(3) -- Go } ACCESS read-write STATUS mandatory DESCRIPTION "Administrative State of Entry." ::= { sfpsServiceCenterConnectEntry 5 } sfpsServiceCenterConnectStatusTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time Tick of last operStatus change." ::= { sfpsServiceCenterConnectEntry 6 } sfpsServiceCenterConnectRequests OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Requests made to server." ::= { sfpsServiceCenterConnectEntry 7 } sfpsServiceCenterConnectResponses OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "GOOD replies by server." ::= { sfpsServiceCenterConnectEntry 8 } END