CTRON-SFPS-EVENTLOG-MIB device MIB details by Enterasys Networks Inc
CTRON-SFPS-EVENTLOG-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-SFPS-EVENTLOG-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-SFPS-EVENTLOG-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-SFPS-EVENTLOG-MIB DEFINITIONS ::= BEGIN -- sfps-eventlog-mib.txt -- Revision: 0.0.04 -- -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- -- This module provides authoritative definitions for Cabletron's -- enterprise specific Fast Packet Switching Services API MIB. -- -- This module will be extended, as required. -- -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright October 93 Cabletron Systems -- IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB -- tcl enterprises IpAddress, -- Counter, Gauge TimeTicks FROM RFC1155-SMI -- These Objects are defined in the file sfps-inc.mib.txt sfpsEventLogStats, sfpsEventLogGenConfig, sfpsEventLogClientConfig, sfpsEventLogClientConfigAPI, sfpsFragStats, sfpsTrapAPI, sfpsTrapTable FROM CTRON-SFPS-INCLUDE-MIB; -- Textual Conventions SfpsSwitchInstance ::= OCTET STRING (SIZE(4)) -- this will map to chassis.module index value --SfpsSwitchPort ::= INTEGER -- this will map to chassis.module.portgroup.portsubgroup.port index value --SfpsAddress ::= OCTET STRING (SIZE (6)) -- this will map to a MAC address HexInteger ::= INTEGER -- display this integer in hex format -- SFPS Event Logger Statistics Group (new event logger) sfpsEventLogStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpsEventLogStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the event information produced by the Event Log Server object." ::= { sfpsEventLogStats 1 } sfpsEventLogStatsEntry OBJECT-TYPE SYNTAX SfpsEventLogStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains event log data." INDEX { sfpsEventLogStatsSwInst, sfpsEventLogWindowStart } ::= { sfpsEventLogStatsTable 1 } SfpsEventLogStatsEntry ::= SEQUENCE { sfpsEventLogStatsSwInst SfpsSwitchInstance, sfpsEventLogWindowStart INTEGER, sfpsEventLogIndex INTEGER, sfpsEventLogClientName DisplayString, sfpsEventLogLevel DisplayString, sfpsEventLogMessageString DisplayString, sfpsEventLogTime TimeTicks, sfpsEventLogCallTag HexInteger, sfpsEventLogInfo1 HexInteger, sfpsEventLogInfo2 HexInteger } sfpsEventLogStatsSwInst OBJECT-TYPE SYNTAX SfpsSwitchInstance ACCESS read-only STATUS mandatory DESCRIPTION "The switch instance of this Event Logger." ::= { sfpsEventLogStatsEntry 1 } sfpsEventLogWindowStart OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the event log window." ::= { sfpsEventLogStatsEntry 2 } sfpsEventLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The absolutue index into the event log window." ::= { sfpsEventLogStatsEntry 3 } sfpsEventLogClientName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the client who logged the event." ::= { sfpsEventLogStatsEntry 4 } sfpsEventLogLevel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The log level of the logged event." ::= { sfpsEventLogStatsEntry 5 } sfpsEventLogMessageString OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The logged event message." ::= { sfpsEventLogStatsEntry 6 } sfpsEventLogTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time when the event was logged." ::= { sfpsEventLogStatsEntry 7 } sfpsEventLogCallTag OBJECT-TYPE SYNTAX HexInteger ACCESS read-only STATUS mandatory DESCRIPTION "The call tag of the logged event (if applicable)." ::= { sfpsEventLogStatsEntry 8 } sfpsEventLogInfo1 OBJECT-TYPE SYNTAX HexInteger ACCESS read-only STATUS mandatory DESCRIPTION "A generic info field used to display information related to the logged event." ::= { sfpsEventLogStatsEntry 9 } sfpsEventLogInfo2 OBJECT-TYPE SYNTAX HexInteger ACCESS read-only STATUS mandatory DESCRIPTION "A generic info field used to display information related to the logged event." ::= { sfpsEventLogStatsEntry 10 } -- SFPS Event Logger General Configuration Group (new event logger) sfpsEventLogGenConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpsEventLogGenConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the general configuration parameters for the Event Log Server object." ::= { sfpsEventLogGenConfig 1 } sfpsEventLogGenConfigEntry OBJECT-TYPE SYNTAX SfpsEventLogGenConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains event log configuration parameters." INDEX { sfpsEventLogGenConfigSwInst } ::= { sfpsEventLogGenConfigTable 1 } SfpsEventLogGenConfigEntry ::= SEQUENCE { sfpsEventLogGenConfigSwInst SfpsSwitchInstance, sfpsEventLogGenConfigWindowStart INTEGER (1..20000), sfpsEventLogGenConfigLoggingIndex INTEGER (1..20000), sfpsEventLogGenConfigMessageFilter DisplayString, sfpsEventLogGenConfigCallTagFilter HexInteger, sfpsEventLogGenConfigAdminStatus INTEGER, sfpsEventLogGenConfigOperStatus INTEGER, sfpsEventLogGenConfigOperTime TimeTicks, sfpsEventLogGenConfigAutoFreeze INTEGER, sfpsEventLogGenConfigDisplayWrapDetect INTEGER, sfpsEventLogGenConfigAdvertiseAddr IpAddress } sfpsEventLogGenConfigSwInst OBJECT-TYPE SYNTAX SfpsSwitchInstance ACCESS read-only STATUS mandatory DESCRIPTION "The switch instance of this Event Logger table." ::= { sfpsEventLogGenConfigEntry 1 } sfpsEventLogGenConfigWindowStart OBJECT-TYPE SYNTAX INTEGER (1..20000) ACCESS read-write STATUS mandatory DESCRIPTION "Represents the starting point of the Event Logger Window." ::= { sfpsEventLogGenConfigEntry 2 } sfpsEventLogGenConfigLoggingIndex OBJECT-TYPE SYNTAX INTEGER (1..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Pointer to the next location where the event logger will log." ::= { sfpsEventLogGenConfigEntry 3 } sfpsEventLogGenConfigMessageFilter OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A string filter which allows only matching messages to be displayed." ::= { sfpsEventLogGenConfigEntry 4 } sfpsEventLogGenConfigCallTagFilter OBJECT-TYPE SYNTAX HexInteger ACCESS read-write STATUS mandatory DESCRIPTION "A filter which allows only messages with matching call tags to be displayed." ::= { sfpsEventLogGenConfigEntry 5 } sfpsEventLogGenConfigAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3), reset(4), continue(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The administrative status of the event log." ::= { sfpsEventLogGenConfigEntry 6 } sfpsEventLogGenConfigOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3), pending-disable(4), pending-enable(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the event log." ::= { sfpsEventLogGenConfigEntry 7 } sfpsEventLogGenConfigOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time that the event log has been in its current operational state." ::= { sfpsEventLogGenConfigEntry 8 } sfpsEventLogGenConfigAutoFreeze OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows events with the Freeze log level to automatically disable the operational status of the event log." ::= { sfpsEventLogGenConfigEntry 9 } sfpsEventLogGenConfigDisplayWrapDetect OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows the event log to not advance past a wrap-point determined by the event log's current logging point." ::= { sfpsEventLogGenConfigEntry 10 } sfpsEventLogGenConfigAdvertiseAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of a remote event logging mechanism." ::= { sfpsEventLogGenConfigEntry 11 } -- SFPS Event Logger Client Configuration Group (new event logger) sfpsEventLogClientConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfpsEventLogClientConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the client configuration parameters for the Event Log Server object." ::= { sfpsEventLogClientConfig 1 } sfpsEventLogClientConfigEntry OBJECT-TYPE SYNTAX SfpsEventLogClientConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains event log client configuration parameters." INDEX { sfpsEventLogClientConfigId } ::= { sfpsEventLogClientConfigTable 1 } SfpsEventLogClientConfigEntry ::= SEQUENCE { sfpsEventLogClientConfigId INTEGER, sfpsEventLogClientConfigName DisplayString, sfpsEventLogClientLogStatus INTEGER, sfpsEventLogClientDisplayStatus INTEGER, sfpsEventLogClientFreezeLogStatus INTEGER, sfpsEventLogClientFreezeDisplayStatus INTEGER, sfpsEventLogClientErrorLogStatus INTEGER, sfpsEventLogClientErrorDisplayStatus INTEGER, sfpsEventLogClientCriticalLogStatus INTEGER, sfpsEventLogClientCriticalDisplayStatus INTEGER, sfpsEventLogClientInfoLogStatus INTEGER, sfpsEventLogClientInfoDisplayStatus INTEGER, sfpsEventLogClientDebugLogStatus INTEGER, sfpsEventLogClientDebugDisplayStatus INTEGER } sfpsEventLogClientConfigId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Represents the client ID of a client that is logging events." ::= { sfpsEventLogClientConfigEntry 1 } sfpsEventLogClientConfigName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the event log client." ::= { sfpsEventLogClientConfigEntry 2 } sfpsEventLogClientLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the logging status for this event log client." ::= { sfpsEventLogClientConfigEntry 3 } sfpsEventLogClientDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for this event log client." ::= { sfpsEventLogClientConfigEntry 4 } sfpsEventLogClientFreezeLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the log status for the log level Freeze of this client." ::= { sfpsEventLogClientConfigEntry 5 } sfpsEventLogClientFreezeDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for the log level Freeze of this client." ::= { sfpsEventLogClientConfigEntry 6 } sfpsEventLogClientErrorLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the log status for the log level Error of this client." ::= { sfpsEventLogClientConfigEntry 7 } sfpsEventLogClientErrorDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for the log level Error of this client." ::= { sfpsEventLogClientConfigEntry 8 } sfpsEventLogClientCriticalLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the log status for the log level Critical of this client." ::= { sfpsEventLogClientConfigEntry 9 } sfpsEventLogClientCriticalDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for the log level Critical of this client." ::= { sfpsEventLogClientConfigEntry 10 } sfpsEventLogClientInfoLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the log status for the log level Info of this client." ::= { sfpsEventLogClientConfigEntry 11 } sfpsEventLogClientInfoDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for the log level Info of this client." ::= { sfpsEventLogClientConfigEntry 12 } sfpsEventLogClientDebugLogStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the log status for the log level Debug of this client." ::= { sfpsEventLogClientConfigEntry 13 } sfpsEventLogClientDebugDisplayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Represents the display status for the log level Debug of this client." ::= { sfpsEventLogClientConfigEntry 14 } sfpsEventLogClientConfigAPIVerb OBJECT-TYPE SYNTAX INTEGER { freezeLog(1), errorLog(2), criticalLog(3), infoLog(4), debugLog(5), allLogLevels(6), allClients(7), masterLog(8) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsEventLogClientConfigAPI 1 } sfpsEventLogClientConfigAPIAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsEventLogClientConfigAPI 2 } sfpsEventLogClientConfigAPIClientName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsEventLogClientConfigAPI 3 } sfpsEventLogClientConfigAPIClientID OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsEventLogClientConfigAPI 4 } sfpsEventLogClientConfigAPILogDisplay OBJECT-TYPE SYNTAX INTEGER { other(1), logAndDisplay(2), logOnly(3), displayOnly(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsEventLogClientConfigAPI 5 } -- Frag Stats sfpsFragStatsTotalFrags OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 1 } sfpsFragStatsNumLookupFail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 2 } sfpsFragStatsAvgCompares OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 3 } sfpsFragStatsNumNodes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 4 } sfpsFragStatsNumUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 5 } sfpsFragStatsMaxNumUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 6 } sfpsFragStatsNumStolen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsFragStats 7 } -- sfpsTrapAPIVerb OBJECT-TYPE SYNTAX INTEGER { other(1), enable(2), disable(3), resetTrapStats(4), resetAllStats(5) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsTrapAPI 1 } sfpsTrapAPITrapId OBJECT-TYPE SYNTAX INTEGER { newUser(1400), violation(1401), srcBlock(1402), dstBlock(1403), portToStandby(1404), portFromStandby(1405), ageCnt(1406), changeCount(1407), foundNeighbor(1408), lostNeighbor(1409), agentIP(1410) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { sfpsTrapAPI 2 } sfpsTrapAPITotalSent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsTrapAPI 3 } -- sfpsTrapTableTrapId OBJECT-TYPE SYNTAX INTEGER { newUser(1400), violation(1401), srcBlock(1402), dstBlock(1403), portToStandby(1404), portFromStandby(1405), ageCnt(1406), changeCount(1407), foundNeighbor(1408), lostNeighbor(1409), agentIP(1410), noSrcVlans(1411), noDestVlans(1412), noSrcVlansEnabled(1413), noDestVlansEnabled(1414), noCommonSecureVlan(1415), incVlanUserCount(1416), decVlanUserCount(1417), vrrpPrimaryResign(1418), vrrpPrimaryAged(1419), vrrpSecondaryUp(1420), hsrpPrimaryResign(1421), hsrpSecondaryUp(1422) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsTrapTable 1 } sfpsTrapTableAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsTrapTable 2 } sfpsTrapTableNumSent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsTrapTable 3 } sfpsTrapTableLastSent OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { sfpsTrapTable 4 } END