The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-SSR-HARDWARE-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-SSR-HARDWARE-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-SSR-HARDWARE-MIB DEFINITIONS ::= BEGIN -- This module provides authoritative definitions for Cabletron's -- enterprise-specific schema to access SSR Hardware configuration. -- -- This module will be extended, as required. -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright June 1998-2000 Cabletron Systems IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter64, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ssrMibs FROM CTRON-SSR-SMI-MIB; hardwareMIB MODULE-IDENTITY LAST-UPDATED "200007170000Z" -- July 17, 2000 ORGANIZATION "Cabletron Systems, Inc." CONTACT-INFO "Enterasys Networks 35 Industrial Way, P.O. Box 5005 Rochester, NH 03867-0505 (603) 332-9400 support@enterasys.com http://www.enterasys.com" DESCRIPTION "This module defines a schema to access SSR hardware configuration." REVISION "200007170000Z" DESCRIPTION "Add support for the Smart Switch 6000 2 Port Gigabit Backplane module to the SSRModuleType for the Enterasys SSR product line" REVISION "200007150000Z" DESCRIPTION "Update contact information. This mib is found on Riverstone Networks RS product line as well as Enterasys SSR product line" REVISION "200005310000Z" DESCRIPTION "Modify SSRPortConnectorType for GBIC connector in 4.0 and update sysHwModuleService by appending the board serial number for 4.0 for RS-32000." REVISION "200003200000Z" DESCRIPTION "Add Firmware 4.0 support. 3200 series modules, gigabit modules with GBIC support." REVISION "9912300000Z" DESCRIPTION "Add Firmware 3.1 support. 16 port 10/100 TX, Gigabit over Copper, ATM OC-3, POS OC3/12." REVISION "9901200000Z" DESCRIPTION "Add Firmware 3.0 support. Add Backup control module status and last Hotswap event." REVISION "9808040000Z" DESCRIPTION "First Revision of SSR Hardware mib. " ::= { ssrMibs 200 } -- InterfaceIndex contains the semantics of ifIndex and -- should be used for any objects defined on other mib -- modules that need these semantics. SSRInterfaceIndex ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub- layer must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization." SYNTAX INTEGER (0..65535) SSRModuleType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A unique value, greater than zero, for each module type supported by the SSR series of products." SYNTAX INTEGER { controlModule(1), -- The Control Module type I ether100TX(2), -- 10 or 100 Mbps Ethernet, 8 port RJ45 ether100FX(3), -- 100 Mbps Ethernet Fiber gigabitSX(4), -- Gigabit SX Fiber (1000 Mbps Ethernet) gigabitLX(5), -- Gigabit LX Fiber (1000 Mbps Ethernet) serial4port(6), -- WAN DS1 speed 4 ports hssi(7), -- WAN DS3 speed 2 ports unknown(8), -- unknown module detected gigabitLLX(9), -- Gigabit LLX Fiber (1000 Mbps Ethernet) 2 port none(10), -- no card present in slot controlModule2(11), -- Control Module type II (Elan) gigabitLLX2P(12), -- Gigabit LLX Fiber (1000 Mbps Ethernet) 1 port serial2port(13), -- WAN DS1 2 ports cmts1x4port(15), -- Cable Modem Termination System 1 downstream 4 upstream fddi2port(16), controlModule3(17), -- Control Module type III (Esprit) serial4portCE(20), -- WAN 4 port Serial Compression & Encrpytion ether100TX16port(21), -- 10 or 100 Mbps Ethernet 16 port gigabitTX(22), -- Gigabit SX TX (1000 Mbps Ethernet over copper) atm155(24), -- ATM 1.5-155 2 port with modular physical port connectors sonet4PortOc3(25), -- Packet over SONET 4 ports Oc3 sonet2PortOc12(26), -- Packet over SONET 2 ports Oc12 gigabitFX4P(27), -- 4 Port Gigabit Ethernet short haul gigabitFX4PGBIC(28), -- 4 Port Gigabit Ethernet with modular physical port connectors gigabitFX2PGBIC(29), -- 2 Port Gigabit Ethernet with modular physical port connectors gigabit6K2PBP(30), -- 2 Port Gigabit SS6000 Backplane port -- 32000 chasss modules rbGigabit8PGBIC(503), -- 8 Port Gigabit Ethernet with modular physical port connectors rbGigabit4PGBIC(504), -- 4 Port Gigabit Ethernet with modular physical port connectors rbEther100TX24P(505), -- 24 Port 10/100 Mbps Ethernet RJ45 rbEther100TC32P(506), -- 32 Port 10/100 Mbps Ethernet Telco rbControlModule(507) -- 32000 Control Module } SSRModuleStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Current state of module. online indicates the normal state. Offline indicates a powered off or failed module. Modules may be powered off prior to hot swap." SYNTAX INTEGER { online(1), -- Module working normally offline(2) -- Module is powered off } SSRPortType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A unique value, greater than zero, for each physical port type supported by the SSR series of products." SYNTAX INTEGER { etherFast(1), -- 10 Mbps Ethernet or 100 Mbps Fast Ethernet capable port gigEther(2), -- Gigabit (1000 Mbps Ethernet) hssi(3), -- WAN HSSI Interface serial(4), -- WAN T1 High Speed Serial Interface unknown(5), -- unknown Port Type sonet(6), -- Synchronous Optical Network Interface ds1(7), -- Digital Signal 1 aka T1 ds3(8), -- Digital Signal 3 aka T3 cmt(9), -- Cable Modem Termination Interface e1(10), -- E1 Digital Signal e3(11), -- E3 Digital Signal fddi(12) -- FDDI port } SSRPortConnectorType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A unique value, greater than zero, for each physical port type supported by the SSR series of products" SYNTAX INTEGER { empty(0), -- Used for GBIC, No GBIC ( empty) db9m(1), -- DB-9 Male connector db9f(2), -- DB-9 Female connector db15m(3), -- DB-15 Male connector db15f(4), -- DB-15 Female connector db25m(5), -- DB-25 Male connector db25f(6), -- DB-25 Female connector rj11(7), -- RJ-11 type jack rj45(8), -- RJ-45 type jack, also known as MJ-8 aui(9), -- AUI connector ftypef(10), -- CATV F-Type Female connector fiberScMM(11), -- Fiber optics SC connector MultiMode, female connector v35(12), -- V.35 shared 60 pin connector, female connector eia530(13), -- EIA 530 shared 60 pin connector, female connector rs44x(14), -- RS-449/442 shared 60 pin connector, female connector x21(15), -- X.21 shared 60 pin connector, female connector hssi(16), -- HSSI 50 pin connector, female connector unknown(17), -- unknown connector fiberScSM(18), -- Fiber optics SC connector Single Mode, female fiberMTRjMM(19), -- Fiber optics Female MTRJ connector, Single Mode, female connector fiberMTRjSM(20), -- Fiber optics Female MTRJ connector, Single Mode, female connector bncf(21), -- Coaxial BNC Female connector bncm(22), -- Coaxial BNC Male connector rj21(23), -- RJ-21 50 Pin Connector fiberScSMLH(24) -- Fiber optics Single Mode, Long Haul } SSRserviceType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A string that is unique to a module in production. This string is used by Cabletron Service and Manufacturing as to identify shipped inventory." SYNTAX OCTET STRING (SIZE (0..7)) SSRmemorySize ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An integer that represents the size of memory in Megabytes. -1 represents not-available or not-applicable value." SYNTAX INTEGER (-1..2147483647) SSRSwitchingFabricInfo ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A bit string that represents the status of Switching Fabric in the shelf/chassis. Switching Fabric #1 is first 2 bits 0-1, #2 is 2-3. For example, given a 16 slot SSR 8600 which has one Switching Fabric in Switching Fabric Slot #1 (lowest full length midplane slot) the integer value 0x00000007 translates into (bits): 0 0 0 0 0 1 1 1 | | | | | | | +--- switching fabric #1 is present | | +----- switching fabric is primary | + ------ switching fabric #2 is present +--------- switching fabric is standby" SYNTAX INTEGER (0..63) SSRCmLedState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A bit string that represents the status of the active Control Module. Each LED occupies a bit. The value 1 indicates LED is on, 0 is off. The integer value 0x00000015 translates into (bits): 0 0 0 0 1 1 1 1 | | | | | | | +- System OK -- SYS OK | | +--- Heartbeat -- HB | +----- Error -- ERR + ------ Diagnostic -- Diag" SYNTAX INTEGER (0..15) SSRBackupCMState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A enumeration that represents the state of the backup control module. A backup control module prom will boot the system firmware to an intermediate state and begins sending hello messages to the main cpu and assume the monitor(3) state. If the prom does not boot the backup control module, the active control module will report the status as inactive(2). inactive(2) indicates a failed state as it means the backup control module can not take over for the active control module. If the main cpu fails to respond to the backup control module's periodic status checks and the backup control module is in the standby(3) state, the backup control module will reset the active control module, then reset all line cards and then finish a normal boot sequence so that it becomes the master. At this point, the value of this object is active(5). Flows in the hardware must be reprogrammed and all control protocols will have to reestablish. An enterprise trap may also be sent. Normally, slot: CM will be the primary control module. CM/1 is the slot for the backup control module. If some other line card exists in slot CM/1 or no card exists, the state of this object is notInstalled(4)." SYNTAX INTEGER { unknown(1), -- status unavailable to snmp agent inactive(2), -- backup control module is offline standby(3), -- CM in backup slot CM/1 is standby notInstalled(4), -- no backup cm installed in Slot: cm/1 active(5) -- CM in backup slot CM/1 is active } -- ### groups ### sysHwGroup OBJECT IDENTIFIER ::= { ssrMibs 1 } sysHwNumSlots OBJECT-TYPE SYNTAX INTEGER (0..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of slots present in the Shelf/Chassis." ::= { sysHwGroup 1 } -- the Slot Table -- The Slot table contains information on the entity's -- plugged in modules. Each slot can have a module plugged in with -- different network interfaces and versions. -- The system show hardware command reports the same data as this table sysHwModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF SysHwModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of module entries." ::= { sysHwGroup 2 } sysHwModuleEntry OBJECT-TYPE SYNTAX SysHwModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular module." INDEX { sysHwModuleSlotNumber} ::= { sysHwModuleTable 1 } SysHwModuleEntry ::= SEQUENCE { sysHwModuleSlotNumber INTEGER, sysHwModuleType SSRModuleType, sysHwModuleDesc OCTET STRING, sysHwModuleNumPorts INTEGER, sysHwModuleVersion OCTET STRING, sysHwModuleMemory SSRmemorySize, sysHwModuleService SSRserviceType, sysHwModuleStatus SSRModuleStatus } sysHwModuleSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..65) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical slot number of the module in the Shelf/Chassis." ::= { sysHwModuleEntry 1 } sysHwModuleType OBJECT-TYPE SYNTAX SSRModuleType MAX-ACCESS read-only STATUS current DESCRIPTION "The physical module type." ::= { sysHwModuleEntry 2 } sysHwModuleDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the module with it's version number etc. For the Control Module it should have the software version, the amount of dynamic RAM, flash RAM." ::= { sysHwModuleEntry 3 } sysHwModuleNumPorts OBJECT-TYPE SYNTAX INTEGER (0..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical ports on this Card/Module." ::= { sysHwModuleEntry 4 } sysHwModuleVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The alpha-numeric version string for this Card/Module." ::= { sysHwModuleEntry 5 } sysHwModuleMemory OBJECT-TYPE SYNTAX SSRmemorySize MAX-ACCESS read-only STATUS current DESCRIPTION "System Memory size available on the Module. Reports -1 if no memory exists on this module, such as power supplies." ::= { sysHwModuleEntry 6 } sysHwModuleService OBJECT-TYPE SYNTAX SSRserviceType MAX-ACCESS read-only STATUS current DESCRIPTION "The Cabletron service identifier string for this Card/Module.The board serial number is appended to the string too." ::= { sysHwModuleEntry 8 } sysHwModuleStatus OBJECT-TYPE SYNTAX SSRModuleStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this module, online or offline." ::= { sysHwModuleEntry 9 } -- the Module Port Table -- The Module table contains information on the entity's -- ports belonging to various modules. sysHwPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SysHwPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of module entries." ::= { sysHwGroup 3 } sysHwPortEntry OBJECT-TYPE SYNTAX SysHwPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular module." INDEX { sysHwPortSlotNumber, sysHwPortNumber} ::= { sysHwPortTable 1 } SysHwPortEntry ::= SEQUENCE { sysHwPortSlotNumber INTEGER, sysHwPortNumber INTEGER, sysHwPortType SSRPortType, sysHwPortConnectorType SSRPortConnectorType, sysHwPortIfIndex SSRInterfaceIndex } sysHwPortSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical slot number of the module in the Chassis." ::= { sysHwPortEntry 1 } sysHwPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The port number of the physical port in the Card/Module." ::= { sysHwPortEntry 2 } sysHwPortType OBJECT-TYPE SYNTAX SSRPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port type." ::= { sysHwPortEntry 3 } sysHwPortConnectorType OBJECT-TYPE SYNTAX SSRPortConnectorType MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port connector type." ::= { sysHwPortEntry 4 } sysHwPortIfIndex OBJECT-TYPE SYNTAX SSRInterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ifIndex used to access this port in the Interface MIB." ::= { sysHwPortEntry 5 } -- SSR 8 system hardware group PowerSupplyBits ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The encoding of the bits are as follows : Each power supply in the system is represented by two bits. The lower bit reflecting the presence of the power supply and the higher bit representing it's state. A 1 reflects a properly working power supply a 0 one which is down. This encoding allows for a maximum of 16 power supplies. For example : The integer value 0x00000007 translates into 0 0 0 0 0 1 1 1 in bits | | | | | | | +- power supply 1 is present | | +--- power supply 1 is working normally | +----- power supply 2 is present +------- power supply 2 is down" SYNTAX INTEGER (0..255) sysHwPowerSupply OBJECT-TYPE SYNTAX PowerSupplyBits MAX-ACCESS read-only STATUS current DESCRIPTION "The number and status of power supplies powering the Shelf/Chassis." ::= { sysHwGroup 4 } sysHwFan OBJECT-TYPE SYNTAX INTEGER { working (1), notWorking(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the fans located inside the Shelf/Chassis." ::= { sysHwGroup 5 } sysHwTemperature OBJECT-TYPE SYNTAX INTEGER { normal(1), outOfRange(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status of the Shelf/Chassis." ::= { sysHwGroup 6 } -- Chassis Id sysHwChassisId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Operator defined serial number for this particular chassis/shelf." ::= { sysHwGroup 7 } sysHwSwitchingFabric OBJECT-TYPE SYNTAX SSRSwitchingFabricInfo MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Switching Fabric in shelf/chassis." ::= { sysHwGroup 19 } sysHwControlModuleLED OBJECT-TYPE SYNTAX SSRCmLedState MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the shelf/chassis Active Control Module's four LED displays." ::= { sysHwGroup 20 } sysHwControlModuleBackupState OBJECT-TYPE SYNTAX SSRBackupCMState MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the the backup Control Module as interpreted from the active control module. CLI: system show hardware will present the following data: Redundant CPU slot : Not present" ::= { sysHwGroup 21 } sysHwLastHotSwapEvent OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the last hotswap of a physical module event occured." ::= { sysHwGroup 22 } -- Deprecated Variables Aggregation Counter Group sysHwTotalInOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The total number of octets into the switch." ::= { sysHwGroup 10 } sysHwTotalOutOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The total number of octets out of the switch." ::= { sysHwGroup 11 } sysHwTotalInFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The total number of frames into the switch." ::= { sysHwGroup 12 } sysHwTotalOutFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The total number of frames out of the switch." ::= { sysHwGroup 13 } sysHwTotalL2SwitchedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current number of frames switched at Layer 2 (transport)." ::= { sysHwGroup 14 } sysHwTotalL3SwitchedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current number of frames switched at IETF Layers 3 (transport) and 4 (application)." ::= { sysHwGroup 15 } -- ### Compliance ### hwConformance OBJECT IDENTIFIER ::= { hardwareMIB 2 } hwCompliances OBJECT IDENTIFIER ::= { hwConformance 1 } hwGroups OBJECT IDENTIFIER ::= { hwConformance 2 } hwComplianceV10 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the SSR-HARDWARE-MIB." MODULE -- this module MANDATORY-GROUPS { hwConfGroupV10 } ::= { hwConfGroupV10 1 } hwComplianceV11 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the SSR-HARDWARE-MIB." MODULE -- this module MANDATORY-GROUPS { hwConfGroupV11 } ::= { hwConfGroupV11 2 } hwComplianceV12 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the SSR-HARDWARE-MIB." MODULE -- this module MANDATORY-GROUPS { hwConfGroupV11 } ::= { hwConfGroupV11 3 } hwComplianceV30 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the SSR-HARDWARE-MIB." MODULE -- this module MANDATORY-GROUPS { hwConfGroupV30 } ::= { hwConfGroupV11 4 } hwConfGroupV10 OBJECT-GROUP OBJECTS { sysHwNumSlots, sysHwModuleSlotNumber, sysHwModuleType, sysHwModuleDesc, sysHwModuleNumPorts, sysHwModuleVersion, sysHwPortSlotNumber, sysHwPortNumber, sysHwPortType, sysHwPortConnectorType, sysHwPortIfIndex, sysHwPowerSupply, sysHwFan, sysHwTemperature, sysHwChassisId, sysHwTotalInOctets, sysHwTotalOutOctets, sysHwTotalInFrames, sysHwTotalOutFrames, sysHwTotalL2SwitchedFrames, sysHwTotalL3SwitchedFrames } STATUS deprecated DESCRIPTION "A set of managed objects that make up version 1.0 of the SSR Hardware mib." ::= { hwGroups 1 } hwConfGroupV11 OBJECT-GROUP OBJECTS { sysHwNumSlots, sysHwModuleSlotNumber, sysHwModuleType, sysHwModuleDesc, sysHwModuleNumPorts, sysHwModuleVersion, sysHwModuleMemory, sysHwModuleService, sysHwPortSlotNumber, sysHwPortNumber, sysHwPortType, sysHwPortConnectorType, sysHwPortIfIndex, sysHwPowerSupply, sysHwFan, sysHwTemperature, sysHwChassisId, sysHwSwitchingFabric, sysHwControlModuleLED } STATUS deprecated DESCRIPTION "A set of managed objects that make up version 1.1 of the SSR Hardware mib." ::= { hwGroups 2 } hwConfGroupV12 OBJECT-GROUP OBJECTS { sysHwNumSlots, sysHwModuleSlotNumber, sysHwModuleType, sysHwModuleDesc, sysHwModuleNumPorts, sysHwModuleVersion, sysHwModuleMemory, sysHwModuleService, sysHwModuleStatus, sysHwPortSlotNumber, sysHwPortNumber, sysHwPortType, sysHwPortConnectorType, sysHwPortIfIndex, sysHwPowerSupply, sysHwFan, sysHwTemperature, sysHwChassisId, sysHwSwitchingFabric, sysHwControlModuleLED } STATUS deprecated DESCRIPTION "A set of managed objects that make up version 1.2 of the SSR Hardware mib." ::= { hwGroups 3 } hwConfGroupV30 OBJECT-GROUP OBJECTS { sysHwNumSlots, sysHwModuleSlotNumber, sysHwModuleType, sysHwModuleDesc, sysHwModuleNumPorts, sysHwModuleVersion, sysHwModuleMemory, sysHwModuleService, sysHwModuleStatus, sysHwPortSlotNumber, sysHwPortNumber, sysHwPortType, sysHwPortConnectorType, sysHwPortIfIndex, sysHwPowerSupply, sysHwFan, sysHwTemperature, sysHwChassisId, sysHwSwitchingFabric, sysHwControlModuleLED, sysHwControlModuleBackupState, sysHwLastHotSwapEvent } STATUS current DESCRIPTION "A set of managed objects that make up version 3.0 of the SSR Hardware mib." ::= { hwGroups 4 } END