AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTRON-SSR-HARDWARE-MIB

CTRON-SSR-HARDWARE-MIB device MIB details by Enterasys Networks Inc

CTRON-SSR-HARDWARE-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-SSR-HARDWARE-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-SSR-HARDWARE-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTRON-SSR-HARDWARE-MIB DEFINITIONS ::= BEGIN

--  This module provides authoritative definitions for Cabletron's
--  enterprise-specific schema to access SSR Hardware configuration.
--
--  This module will be extended, as required.
 
--  Cabletron Systems reserves the right to make changes in
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.
 
--  Copyright June 1998-2000 Cabletron Systems
 

IMPORTS
   MODULE-IDENTITY, OBJECT-TYPE, Counter64, TimeTicks
   FROM SNMPv2-SMI
   TEXTUAL-CONVENTION        
   FROM SNMPv2-TC
   MODULE-COMPLIANCE, OBJECT-GROUP
   FROM SNMPv2-CONF
   ssrMibs 
   FROM CTRON-SSR-SMI-MIB; 

hardwareMIB MODULE-IDENTITY
    LAST-UPDATED "200007170000Z"  -- July 17, 2000
   ORGANIZATION
     "Cabletron Systems, Inc."
   CONTACT-INFO
    "Enterasys Networks
     35 Industrial Way, P.O. Box 5005
     Rochester, NH 03867-0505
     (603) 332-9400
     support@enterasys.com
     http://www.enterasys.com"
   DESCRIPTION
      "This module defines a schema to access SSR hardware configuration."

    REVISION     "200007170000Z"
    DESCRIPTION
      "Add support for the Smart Switch 6000 2 Port Gigabit Backplane module
       to the SSRModuleType for the  Enterasys SSR product line"

    REVISION     "200007150000Z"
    DESCRIPTION
      "Update contact information. This mib is found on Riverstone Networks RS product line
       as well as Enterasys SSR product line"

    REVISION     "200005310000Z"
    DESCRIPTION
      "Modify SSRPortConnectorType for GBIC connector in 4.0 and update sysHwModuleService  
       by appending the board serial number for 4.0 for RS-32000."

    REVISION     "200003200000Z"
    DESCRIPTION
      "Add Firmware 4.0 support. 3200 series modules, gigabit modules with GBIC support."

    REVISION     "9912300000Z"
    DESCRIPTION
      "Add Firmware 3.1 support. 16 port 10/100 TX, Gigabit over Copper, ATM OC-3, POS OC3/12."

    REVISION     "9901200000Z"
    DESCRIPTION
      "Add Firmware 3.0 support. Add Backup control module status and last Hotswap event."

    REVISION     "9808040000Z"
    DESCRIPTION
       "First Revision of SSR Hardware mib. "
        ::= { ssrMibs 200 }   

   -- InterfaceIndex contains the semantics of ifIndex and
   -- should be used for any objects defined on other mib
   -- modules that need these semantics.

   SSRInterfaceIndex ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A unique value, greater than zero, for each interface
        or interface sub-layer in the managed system.  It is
        recommended that values are assigned contiguously
        starting from 1.  The value for each interface sub-
        layer must remain constant at least from one re-
        initialization of the entity's network management
        system to the next re-initialization."
       SYNTAX       INTEGER (0..65535)

   SSRModuleType ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A unique value, greater than zero, for each module 
        type supported by the SSR series of products."
       SYNTAX       INTEGER {
                controlModule(1),     -- The Control Module type I
                ether100TX(2),        -- 10 or 100 Mbps Ethernet, 8 port RJ45
                ether100FX(3),        -- 100 Mbps Ethernet Fiber  
                gigabitSX(4),         -- Gigabit SX Fiber (1000 Mbps Ethernet)
                gigabitLX(5),         -- Gigabit LX Fiber (1000 Mbps Ethernet)
                serial4port(6),       -- WAN DS1 speed 4 ports
                hssi(7),              -- WAN DS3 speed 2 ports
                unknown(8),           -- unknown module detected
                gigabitLLX(9),        -- Gigabit LLX Fiber (1000 Mbps Ethernet) 2 port
                none(10),             -- no card present in slot
                controlModule2(11),   -- Control Module type II (Elan)
                gigabitLLX2P(12),     -- Gigabit LLX Fiber (1000 Mbps Ethernet) 1 port          
                serial2port(13),      -- WAN DS1 2 ports 
                cmts1x4port(15),      -- Cable Modem Termination System 1 downstream 4 upstream
                fddi2port(16),
                controlModule3(17),   -- Control Module type III (Esprit)
                serial4portCE(20),    -- WAN 4 port Serial Compression & Encrpytion
                ether100TX16port(21), -- 10 or 100 Mbps Ethernet 16 port
                gigabitTX(22),        -- Gigabit SX TX (1000 Mbps Ethernet over copper)
                atm155(24),           -- ATM 1.5-155 2 port with modular physical port connectors  
                sonet4PortOc3(25),    -- Packet over SONET 4 ports Oc3
                sonet2PortOc12(26),   -- Packet over SONET 2 ports Oc12
                gigabitFX4P(27),      -- 4 Port Gigabit Ethernet short haul
                gigabitFX4PGBIC(28),  -- 4 Port Gigabit Ethernet with modular physical port connectors
                gigabitFX2PGBIC(29),  -- 2 Port Gigabit Ethernet with modular physical port connectors
                gigabit6K2PBP(30),    -- 2 Port Gigabit SS6000 Backplane port

                                      -- 32000 chasss modules
                rbGigabit8PGBIC(503), -- 8 Port Gigabit Ethernet with modular physical port connectors
                rbGigabit4PGBIC(504), -- 4 Port Gigabit Ethernet with modular physical port connectors
                rbEther100TX24P(505), -- 24 Port 10/100 Mbps Ethernet RJ45
                rbEther100TC32P(506), -- 32 Port 10/100 Mbps Ethernet Telco
                rbControlModule(507)  -- 32000 Control Module
                }

   SSRModuleStatus ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "Current state of module. online indicates the normal state. Offline indicates a powered off or failed
         module. Modules may be powered off prior to hot swap."
       SYNTAX       INTEGER {
                online(1),        -- Module working normally
                offline(2)        -- Module is powered off
                }

   SSRPortType ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A unique value, greater than zero, for each physical port
        type supported by the SSR series of products."
       SYNTAX   INTEGER {
                etherFast(1),  -- 10 Mbps Ethernet or 100 Mbps Fast Ethernet capable port
                gigEther(2),   -- Gigabit (1000 Mbps Ethernet)
                hssi(3),       -- WAN HSSI Interface 
                serial(4),     -- WAN T1 High Speed Serial Interface 
                unknown(5),    -- unknown Port Type 
                sonet(6),      -- Synchronous Optical Network Interface
                ds1(7),        -- Digital Signal 1 aka T1
                ds3(8),        -- Digital Signal 3 aka T3
                cmt(9),        -- Cable Modem Termination Interface
                e1(10),        -- E1 Digital Signal
                e3(11),        -- E3 Digital Signal
                fddi(12)      -- FDDI port
                }

   SSRPortConnectorType ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A unique value, greater than zero, for each physical port
        type supported by the SSR series of products"
       SYNTAX       INTEGER {
              empty(0),      -- Used for GBIC, No GBIC ( empty)
                db9m(1),           -- DB-9 Male connector
                db9f(2),           -- DB-9 Female connector
                db15m(3),          -- DB-15 Male connector
                db15f(4),          -- DB-15 Female connector
                db25m(5),          -- DB-25 Male connector
                db25f(6),          -- DB-25 Female connector
                rj11(7),           -- RJ-11 type jack
                rj45(8),           -- RJ-45 type jack, also known as MJ-8
                aui(9),            -- AUI connector
                ftypef(10),        -- CATV F-Type Female connector
                fiberScMM(11),     -- Fiber optics SC connector MultiMode, female connector
                v35(12),           -- V.35 shared 60 pin connector, female connector
                eia530(13),        -- EIA 530 shared 60 pin connector, female connector
                rs44x(14),         -- RS-449/442 shared 60 pin connector, female  connector
                x21(15),           -- X.21 shared 60 pin connector, female  connector
                hssi(16),          -- HSSI 50 pin connector, female connector
                unknown(17),       -- unknown connector 
                fiberScSM(18),     -- Fiber optics SC connector Single Mode, female
                fiberMTRjMM(19),   -- Fiber optics Female MTRJ connector, Single Mode, female connector
                fiberMTRjSM(20),   -- Fiber optics Female MTRJ connector, Single Mode, female connector
                bncf(21),          -- Coaxial BNC Female connector
                bncm(22),          -- Coaxial BNC Male connector
                rj21(23),           -- RJ-21 50 Pin Connector
              fiberScSMLH(24)    -- Fiber optics Single Mode, Long Haul
                }

   SSRserviceType ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A string that is unique to a module in production. This string
         is used by Cabletron Service and Manufacturing as 
         to identify shipped inventory."
       SYNTAX OCTET STRING (SIZE (0..7))

   SSRmemorySize ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "An integer that represents the size of memory in Megabytes. -1
         represents not-available or not-applicable value."
       SYNTAX INTEGER (-1..2147483647)


   SSRSwitchingFabricInfo ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A bit string that represents the status of Switching Fabric 
         in the shelf/chassis. Switching Fabric #1 is first 2 bits 0-1,  
         #2 is 2-3.

         For example, given a 16 slot SSR 8600 which has one 
         Switching Fabric in Switching Fabric Slot #1 
         (lowest full length midplane slot) the
         integer value 0x00000007 translates into (bits):
               0 0 0 0 0 1 1 1 
                       | | | |
                       | | | +--- switching fabric #1 is present
                       | | +----- switching fabric is primary
                       | + ------ switching fabric #2 is present 
                       +--------- switching fabric is standby"
       SYNTAX       INTEGER (0..63)

   SSRCmLedState ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A bit string that represents the status of the active Control Module.
         Each LED occupies a bit. The value 1 indicates LED is on, 0 is off.
               The integer value 0x00000015 translates into (bits):
               0 0 0 0 1 1 1 1 
                       | | | |
                       | | | +- System OK  -- SYS OK 
                       | | +--- Heartbeat  -- HB
                       | +----- Error      -- ERR
                       + ------ Diagnostic -- Diag"
       SYNTAX       INTEGER (0..15)

   SSRBackupCMState ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
        "A enumeration that represents the state of the backup control module.

         A backup control module prom will boot the system firmware to an 
         intermediate state and begins sending hello messages to the main cpu
         and assume the monitor(3) state. If the prom does not boot the 
         backup control module, the active control module will report the
         status as inactive(2). inactive(2) indicates a failed state as it 
         means the backup control module can not take over for the active
         control module.

         If the main cpu fails to respond to the backup control module's 
         periodic status checks and the backup control module is in the 
         standby(3) state, the backup control module will reset the active
         control module, then reset all line cards and then finish a normal
         boot sequence so that it becomes the master. At this point, the
         value of this object is active(5).

         Flows in the hardware must be reprogrammed and all control protocols
         will have to reestablish. An enterprise trap may also be sent.

         Normally, slot: CM will be the primary control module. CM/1 is
         the slot for the backup control module. If some other line card
         exists in slot CM/1 or no card exists, the state of this object
          is notInstalled(4)."
       SYNTAX       INTEGER {
                 unknown(1),      -- status unavailable to snmp agent
                 inactive(2),     -- backup control module is offline
                 standby(3),      -- CM in backup slot CM/1 is standby
                 notInstalled(4), -- no backup cm installed in Slot: cm/1
                 active(5)        -- CM in backup slot CM/1 is active
               }

-- ### groups ###

sysHwGroup  OBJECT IDENTIFIER   ::= { ssrMibs 1 }

   sysHwNumSlots  OBJECT-TYPE
       SYNTAX      INTEGER (0..64)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The number of slots present in the Shelf/Chassis."
       ::= { sysHwGroup 1 }

   -- the Slot Table

   -- The Slot table contains information on the entity's
   -- plugged in modules.  Each slot can have a module plugged in with 
   -- different network interfaces and versions.  
   -- The system show hardware command reports the same data as this table

   sysHwModuleTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysHwModuleEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
        "A list of module entries."
       ::= { sysHwGroup 2 }

   sysHwModuleEntry OBJECT-TYPE
       SYNTAX      SysHwModuleEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
        "An entry containing management information applicable
        to a particular module."
       INDEX   { sysHwModuleSlotNumber}
       ::= { sysHwModuleTable 1 }

   SysHwModuleEntry ::=
       SEQUENCE {
           sysHwModuleSlotNumber        INTEGER,
           sysHwModuleType              SSRModuleType,
           sysHwModuleDesc              OCTET STRING,
           sysHwModuleNumPorts          INTEGER,
           sysHwModuleVersion           OCTET STRING,
           sysHwModuleMemory            SSRmemorySize,
           sysHwModuleService           SSRserviceType,
           sysHwModuleStatus            SSRModuleStatus
       }

   sysHwModuleSlotNumber OBJECT-TYPE
       SYNTAX      INTEGER (1..65)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The physical slot number of the module in the Shelf/Chassis."
       ::= { sysHwModuleEntry 1 }

   sysHwModuleType OBJECT-TYPE
       SYNTAX      SSRModuleType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The physical module type."
       ::= { sysHwModuleEntry 2 }

   sysHwModuleDesc OBJECT-TYPE
       SYNTAX      OCTET STRING (SIZE (0..255))
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The description of the module with it's version number etc.
        For the Control Module it should have the software version, the 
        amount of dynamic RAM, flash RAM."
       ::= { sysHwModuleEntry 3 }

   sysHwModuleNumPorts OBJECT-TYPE
       SYNTAX      INTEGER (0..256)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The number of physical ports on this Card/Module."
       ::= { sysHwModuleEntry 4 }

   sysHwModuleVersion OBJECT-TYPE
       SYNTAX      OCTET STRING  (SIZE (1)) 
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The alpha-numeric version string for this Card/Module."
       ::= { sysHwModuleEntry 5 }

   sysHwModuleMemory OBJECT-TYPE
       SYNTAX      SSRmemorySize
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "System Memory size available on the Module. Reports
        -1 if no memory exists on this module, such as power supplies."
       ::= { sysHwModuleEntry 6 }


   sysHwModuleService OBJECT-TYPE
       SYNTAX      SSRserviceType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The Cabletron service identifier string for this Card/Module.The board serial
         number is appended to the string too."
       ::= { sysHwModuleEntry 8 }

   sysHwModuleStatus OBJECT-TYPE
       SYNTAX      SSRModuleStatus 
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The current status of this module, online or offline."
       ::= { sysHwModuleEntry 9 }

   -- the Module Port Table

   -- The Module table contains information on the entity's
   -- ports belonging to various modules.  

   sysHwPortTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF SysHwPortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "A list of module entries."
       ::= { sysHwGroup 3 }

   sysHwPortEntry OBJECT-TYPE
       SYNTAX      SysHwPortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
        "An entry containing management information applicable
        to a particular module."
       INDEX   { sysHwPortSlotNumber, sysHwPortNumber}
       ::= { sysHwPortTable 1 }

   SysHwPortEntry ::=
       SEQUENCE {
           sysHwPortSlotNumber          INTEGER,
           sysHwPortNumber              INTEGER,
           sysHwPortType                SSRPortType,
           sysHwPortConnectorType       SSRPortConnectorType,
           sysHwPortIfIndex             SSRInterfaceIndex
       }

   sysHwPortSlotNumber OBJECT-TYPE
       SYNTAX      INTEGER (1..255)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The physical slot number of the module in the Chassis."
       ::= { sysHwPortEntry 1 }

   sysHwPortNumber OBJECT-TYPE
       SYNTAX      INTEGER (1..255)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The port number of the physical port in the Card/Module."
       ::= { sysHwPortEntry 2 }

   sysHwPortType OBJECT-TYPE
       SYNTAX      SSRPortType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The physical port type."
       ::= { sysHwPortEntry 3 }

   sysHwPortConnectorType OBJECT-TYPE
       SYNTAX      SSRPortConnectorType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The physical port connector type."
       ::= { sysHwPortEntry 4 }

   sysHwPortIfIndex OBJECT-TYPE
       SYNTAX      SSRInterfaceIndex 
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The value of ifIndex used to access this port in the Interface MIB."
       ::= { sysHwPortEntry 5 }
 
   
   -- SSR 8 system hardware group

   PowerSupplyBits ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
               "The encoding of the bits are as follows :
               Each power supply in the system is represented by two bits.
               The lower bit reflecting the presence of the power supply and
               the higher bit representing it's state. A 1 reflects a properly
               working power supply a 0 one which is down.
               This encoding allows for a maximum of 16 power supplies.

               For example :
               The integer value 0x00000007 translates into

               0 0 0 0 0 1 1 1 in bits
                       | | | |
                       | | | +- power supply 1 is present
                       | | +--- power supply 1 is working normally
                       | +----- power supply 2 is present
                       +------- power supply 2 is down"
       SYNTAX       INTEGER (0..255)

   sysHwPowerSupply OBJECT-TYPE
           SYNTAX  PowerSupplyBits 
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
          "The number and status of power supplies powering the Shelf/Chassis."
       ::= { sysHwGroup 4 }

   sysHwFan OBJECT-TYPE
           SYNTAX  INTEGER {
               working (1),
               notWorking(2),
               unknown(3)
               }
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
        "The current state of the fans located inside the Shelf/Chassis."
       ::= { sysHwGroup 5 }

   sysHwTemperature OBJECT-TYPE
           SYNTAX  INTEGER {
              normal(1),
              outOfRange(2),
              unknown(3)
               }
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
        "The current temperature status of the Shelf/Chassis."
       ::= { sysHwGroup 6 }

   -- Chassis Id

   sysHwChassisId OBJECT-TYPE
       SYNTAX      OCTET STRING (SIZE (0..255))
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "Operator defined serial number for this particular chassis/shelf."
       ::= { sysHwGroup 7 }

   sysHwSwitchingFabric  OBJECT-TYPE
       SYNTAX   SSRSwitchingFabricInfo
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "Status of Switching Fabric in shelf/chassis."
       ::= { sysHwGroup 19 }
 
   sysHwControlModuleLED  OBJECT-TYPE
       SYNTAX   SSRCmLedState
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "Status of the shelf/chassis Active Control Module's four LED displays."
       ::= { sysHwGroup 20 }

   sysHwControlModuleBackupState  OBJECT-TYPE
       SYNTAX   SSRBackupCMState
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "Status of the the backup Control Module as interpreted from the 
         active control module. CLI: system show hardware will present
         the following data: Redundant CPU slot : Not present"
       ::= { sysHwGroup 21 }

   sysHwLastHotSwapEvent  OBJECT-TYPE
       SYNTAX   TimeTicks
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
        "The value of sysUpTime when the last hotswap of a physical module event occured."
       ::= { sysHwGroup 22 }

-- Deprecated Variables Aggregation Counter Group

   sysHwTotalInOctets OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The total number of octets into the switch."
       ::= { sysHwGroup 10 }

   sysHwTotalOutOctets OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The total number of octets out of the switch."
       ::= { sysHwGroup 11 }

   sysHwTotalInFrames OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The total number of frames into the switch."
       ::= { sysHwGroup 12 }

   sysHwTotalOutFrames OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The total number of frames out of the switch."
       ::= { sysHwGroup 13 }

   sysHwTotalL2SwitchedFrames OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The current number of frames switched at Layer 2 (transport)."
       ::= { sysHwGroup 14 }

   sysHwTotalL3SwitchedFrames OBJECT-TYPE
           SYNTAX  Counter64
           MAX-ACCESS  read-only
           STATUS  deprecated
           DESCRIPTION
        "The current number of frames switched at IETF Layers 3 (transport) and
         4 (application)."
       ::= { sysHwGroup 15 }


-- ### Compliance ###

hwConformance OBJECT IDENTIFIER ::= { hardwareMIB 2 }
hwCompliances OBJECT IDENTIFIER ::= { hwConformance 1 }
hwGroups OBJECT IDENTIFIER ::= { hwConformance 2 }
 
hwComplianceV10 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "The compliance statement for the SSR-HARDWARE-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hwConfGroupV10 }
    ::= { hwConfGroupV10 1 }

hwComplianceV11 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "The compliance statement for the SSR-HARDWARE-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hwConfGroupV11 }
    ::= { hwConfGroupV11 2 }

hwComplianceV12 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "The compliance statement for the SSR-HARDWARE-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hwConfGroupV11 }
    ::= { hwConfGroupV11 3 }

hwComplianceV30 MODULE-COMPLIANCE
    STATUS current 
    DESCRIPTION
            "The compliance statement for the SSR-HARDWARE-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { hwConfGroupV30 }
    ::= { hwConfGroupV11 4 }

hwConfGroupV10  OBJECT-GROUP 
   OBJECTS {
        sysHwNumSlots,
        sysHwModuleSlotNumber,
        sysHwModuleType,
        sysHwModuleDesc,
        sysHwModuleNumPorts,
        sysHwModuleVersion,
        sysHwPortSlotNumber,
        sysHwPortNumber,
        sysHwPortType,
        sysHwPortConnectorType,
        sysHwPortIfIndex,
        sysHwPowerSupply,
        sysHwFan,
        sysHwTemperature,
        sysHwChassisId,
        sysHwTotalInOctets,
        sysHwTotalOutOctets,
        sysHwTotalInFrames,
        sysHwTotalOutFrames,
        sysHwTotalL2SwitchedFrames,
        sysHwTotalL3SwitchedFrames
}
  STATUS deprecated
  DESCRIPTION
  "A set of managed objects that make up version 1.0 of the SSR Hardware mib."
   ::= { hwGroups 1 } 

hwConfGroupV11  OBJECT-GROUP 
   OBJECTS {
        sysHwNumSlots,

        sysHwModuleSlotNumber,
        sysHwModuleType,
        sysHwModuleDesc,
        sysHwModuleNumPorts,
        sysHwModuleVersion,
        sysHwModuleMemory,
        sysHwModuleService,
        
        sysHwPortSlotNumber,
        sysHwPortNumber,
        sysHwPortType,
        sysHwPortConnectorType,
        sysHwPortIfIndex,

        sysHwPowerSupply,
        sysHwFan,
        sysHwTemperature,
        sysHwChassisId,

        sysHwSwitchingFabric,
        sysHwControlModuleLED   
}
  STATUS deprecated
  DESCRIPTION
  "A set of managed objects that make up version 1.1 of the SSR Hardware mib."
   ::= { hwGroups 2 } 


hwConfGroupV12  OBJECT-GROUP 
   OBJECTS {
        sysHwNumSlots,

        sysHwModuleSlotNumber,
        sysHwModuleType,
        sysHwModuleDesc,
        sysHwModuleNumPorts,
        sysHwModuleVersion,
        sysHwModuleMemory,
        sysHwModuleService,
        sysHwModuleStatus,         

        sysHwPortSlotNumber,
        sysHwPortNumber,
        sysHwPortType,
        sysHwPortConnectorType,
        sysHwPortIfIndex,

        sysHwPowerSupply,
        sysHwFan,
        sysHwTemperature,
        sysHwChassisId,

        sysHwSwitchingFabric,
        sysHwControlModuleLED   
}
  STATUS deprecated
  DESCRIPTION
  "A set of managed objects that make up version 1.2 of the SSR Hardware mib."
   ::= { hwGroups 3 } 


hwConfGroupV30  OBJECT-GROUP 
   OBJECTS {
        sysHwNumSlots,
        sysHwModuleSlotNumber,
        sysHwModuleType,
        sysHwModuleDesc,
        sysHwModuleNumPorts,
        sysHwModuleVersion,
        sysHwModuleMemory,
        sysHwModuleService,
        sysHwModuleStatus,         

        sysHwPortSlotNumber,
        sysHwPortNumber,
        sysHwPortType,
        sysHwPortConnectorType,
        sysHwPortIfIndex,

        sysHwPowerSupply,
        sysHwFan,
        sysHwTemperature,
        sysHwChassisId,

        sysHwSwitchingFabric,
        sysHwControlModuleLED,
        sysHwControlModuleBackupState,
        sysHwLastHotSwapEvent
}
  STATUS current
  DESCRIPTION
  "A set of managed objects that make up version 3.0 of the SSR Hardware mib."
   ::= { hwGroups 4 } 

END