AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTRON-SSR-TRAP-MIB

CTRON-SSR-TRAP-MIB device MIB details by Enterasys Networks Inc

CTRON-SSR-TRAP-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-SSR-TRAP-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-SSR-TRAP-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTRON-SSR-TRAP-MIB DEFINITIONS ::= BEGIN

--  This module provides authoritative definitions for Enterasys's
--  enterprise-specific Smart Switch Router Traps.
--
--  This module will be extended, as required.
--

--  Enterasys Networks reserves the right to make changes in
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Enterasys Networks
--  to determine whether any such changes have been made.
--
--  In no event shall Enterasys Networks be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Enterasys
--  Networks has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Enterasys grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Enterasys products.

--  Copyright July, 2002 Enterasys Networks, Inc.


IMPORTS
      MODULE-IDENTITY, NOTIFICATION-TYPE
      FROM SNMPv2-SMI
      MODULE-COMPLIANCE, NOTIFICATION-GROUP
      FROM SNMPv2-CONF
      ifIndex
      FROM IF-MIB
      ssrTraps, ssrMibs
      FROM CTRON-SSR-SMI-MIB
      capCPUCurrentUtilization
      FROM CTRON-SSR-CAPACITY-MIB
      polAclName, polAclItem
      FROM CTRON-SSR-POLICY-MIB
      sysHwPowerSupply, sysHwFan, sysHwTemperature, sysHwModuleSlotNumber
      FROM CTRON-SSR-HARDWARE-MIB;

ssrTrapsMIB MODULE-IDENTITY
   LAST-UPDATED "200207231720Z"  -- Tue Jul 23 17:20 GMT 2002
   ORGANIZATION "Enterasys Networks, Inc."
   CONTACT-INFO
    "Postal: Enterasys Networks, Inc.
             35 Industrial Way, P.O. Box 5005
             Rochester, NH 03867-0505
     Phone:  +1 603 332 9400
     E-mail: support@enterasys.com
     WWW:    http://www.enterasys.com"
 
   DESCRIPTION
      "This module describes the traps specific to the Smart Switch Router."

   REVISION     "200207231720Z"  -- Tue Jul 23 17:20 GMT 2002
   DESCRIPTION  "Update contact information. Add notifications for access
                 denial by access control list (ACL) entry."

   REVISION     "200102160000Z"
   DESCRIPTION  "Add notifications for backup control module failure, line
                 card failure, and CPU threshold exceeded."
   ::= { ssrMibs 300 }
 

   trapControl  OBJECT IDENTIFIER       ::=     { ssrTraps 1 }

   envTrapGroup OBJECT IDENTIFIER       ::=     { ssrTraps 2 }

   polTrapGroup OBJECT IDENTIFIER       ::=     { ssrTraps 3 }


    envPowerSupplyFailed NOTIFICATION-TYPE
        OBJECTS { 
                  sysHwPowerSupply
                }
        STATUS             current
        DESCRIPTION
           "A power supply on the sending device has failed. The 
            sysHwPowerSupply object identifies the failed supply."
        ::= { envTrapGroup 1 }

    envPowerSupplyRecovered NOTIFICATION-TYPE
        OBJECTS {
                  sysHwPowerSupply
                }
        STATUS             current
        DESCRIPTION
           "A power supply on the sending device has recovered 
            after failure. The sysHwPowerSupply object identifies 
            the recovered supply."
        ::= { envTrapGroup 2 }

    envFanFailed NOTIFICATION-TYPE
        OBJECTS {
                  sysHwFan
                }
        STATUS             current
        DESCRIPTION
           "A Fan tray on the sending device has failed. The
            sysHwFan object identifies the failed fan tray."
        ::= { envTrapGroup 3 }
 
    envFanRecovered NOTIFICATION-TYPE
        OBJECTS {
                  sysHwFan
                }
        STATUS             current
        DESCRIPTION
           "A Fan tray on the sending device has recovered
            after failure. The sysHwFan object identifies
            the recovered Fan tray."
        ::= { envTrapGroup 4 }
 
    envTempExceeded NOTIFICATION-TYPE
        OBJECTS {
                  sysHwTemperature
                }
        STATUS             current
        DESCRIPTION
           "A temperature inside the chassis on the sending device has exceeded
            normal operating temperature. The sysHwTemperature object
            identifies the current status."
        ::= { envTrapGroup 5 }
 
    envTempNormal NOTIFICATION-TYPE
        OBJECTS {
                  sysHwTemperature
                }
        STATUS             current
        DESCRIPTION
           "A temperature inside the chassis on the sending device has returned
            to normal operating temperature. The sysHwTemperature
            object identifies the current status."
        ::= { envTrapGroup 6 }

    envHotSwapIn NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber
                }
        STATUS             current
        DESCRIPTION
           "A module has been inserted into the chassis.
            sysHwModuleSlotNumber identifies the slot the module was inserted into."
        ::= { envTrapGroup 7 }

    envHotSwapOut NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber
                }
        STATUS             current
        DESCRIPTION
           "A module has been turned off or removed from the chassis.
            sysHwModuleSlotNumber identifies the slot the module was removed from."
        ::= { envTrapGroup 8 }

    envBackupControlModuleOnline NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber
                }
        STATUS             current
        DESCRIPTION
           "A backup control module that was in standby mode has taken over 
            for a failed primary control module. Poll sysHwControlModuleBackupState 
            for current state of backup control module. sysHwModuleSlotNumber is the index
            into the sysHwModuleTable for the now active control module."
        ::= { envTrapGroup 9 }


    envBackupControlModuleFailure NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber
                }
        STATUS             current
        DESCRIPTION
           "A backup control module that was in standby mode has changed to 
            inactive or notInstalled. Poll sysHwControlModuleBackupState 
            for current state of backup control module."
        ::= { envTrapGroup 10 }

    envLineModuleFailure NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber
                }
        STATUS             current
        DESCRIPTION
           "A line card module which was in the online state changed to the 
            offline state indicating an error condition."
        ::= { envTrapGroup 11 }

    envCPUThresholdExceeded NOTIFICATION-TYPE
        OBJECTS {
                  sysHwModuleSlotNumber,
                  capCPUCurrentUtilization
                }
        STATUS             current
        DESCRIPTION
           "The CPU utilization has exceeded the value of capCPUMaxThreshold
            after having been below the value of capCPUMinThreshold. Once 
            this trap has occurred it will not occurred again until the
            utilization has dropped below capCPUMinThreshold. Poll
            capCPUMinThreshold and capCPUMaxThreshold to determine the
            configured threshold settings."
        ::= { envTrapGroup 12 }


   polNotifications    OBJECT IDENTIFIER   ::= { polTrapGroup 0 }

   polAclDenied NOTIFICATION-TYPE
     OBJECTS      { polAclName,
                    polAclItem,
                    ifIndex
                  }
     STATUS       current
     DESCRIPTION
         "The polAclDenied trap indicates that a message was
          dropped because of a 'deny' ACL. The polAclName and polAclItem
          identify the entry in the polAclTable. The ifIndex value identifies
          the interface on which the deny ACL was applied."
     ::= { polNotifications 1 }

--
-- Conformance Section
--
ssrTrapsConformance OBJECT IDENTIFIER ::= { ssrTrapsMIB 2 }
ssrTrapsCompliances OBJECT IDENTIFIER ::= { ssrTrapsConformance 1 }
ssrTrapsGroups OBJECT IDENTIFIER ::= { ssrTrapsConformance 2 }


-- MODULE-COMPLIANCE 

 
ssrTrapsComplianceV10 MODULE-COMPLIANCE
    STATUS obsolete
    DESCRIPTION
            "The compliance statement for the CTRON-SSR-TRAPS-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { ssrTrapsConfGroupV10 }
    ::= { ssrTrapsConfGroupV10 1 }

ssrTrapsComplianceV20 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "The compliance statement for the CTRON-SSR-TRAPS-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { ssrTrapsConfGroupV20 }
    ::= { ssrTrapsConfGroupV20 1 }

ssrTrapsComplianceV30 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "The compliance statement for the CTRON-SSR-TRAPS-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { ssrTrapsConfGroupV30 }
    ::= { ssrTrapsConfGroupV30 1 }

ssrTrapsComplianceV40 MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
            "The compliance statement for the CTRON-SSR-TRAPS-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { ssrTrapsConfGroupV40 }
    ::= { ssrTrapsConfGroupV40 1 }

ssrTrapsComplianceV50 MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
            "The compliance statement for the CTRON-SSR-TRAPS-MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { ssrTrapsConfGroupV50 }
    ::= { ssrTrapsConfGroupV50 1 }



-- Notification Groups


ssrTrapsConfGroupV10  NOTIFICATION-GROUP 
   NOTIFICATIONS {
      envPowerSupplyFailed,
      envPowerSupplyRecovered
}
 STATUS obsolete
 DESCRIPTION
  "A set of managed objects that make up version 1.0 of the SSR Trap MIB."
    ::= { ssrTrapsGroups 1 } 

ssrTrapsConfGroupV20  NOTIFICATION-GROUP 
   NOTIFICATIONS {
      envPowerSupplyFailed,
      envPowerSupplyRecovered,
      envFanFailed,
      envFanRecovered,
      envTempExceeded,
      envTempNormal
}
 STATUS deprecated
 DESCRIPTION
  "A set of managed objects that make up version 2.0 of the SSR Trap MIB."
    ::= { ssrTrapsGroups 2 } 

ssrTrapsConfGroupV30  NOTIFICATION-GROUP 
   NOTIFICATIONS {
      envPowerSupplyFailed,
      envPowerSupplyRecovered,
      envFanFailed,
      envFanRecovered,
      envTempExceeded,
      envTempNormal,
      envHotSwapIn,
      envHotSwapOut
}
 STATUS deprecated
 DESCRIPTION
  "A set of managed objects that make up version 3.0 of the SSR Trap MIB."
    ::= { ssrTrapsGroups 3 } 

ssrTrapsConfGroupV40  NOTIFICATION-GROUP 
   NOTIFICATIONS {
      envPowerSupplyFailed,
      envPowerSupplyRecovered,
      envFanFailed,
      envFanRecovered,
      envTempExceeded,
      envTempNormal,
      envHotSwapIn,
      envHotSwapOut,
      envBackupControlModuleOnline,
      envBackupControlModuleFailure,
      envLineModuleFailure,
      envCPUThresholdExceeded
}
 STATUS deprecated
 DESCRIPTION
  "A set of managed objects that make up version 4.0 of the SSR Trap MIB."
    ::= { ssrTrapsGroups 4 } 

ssrTrapsConfGroupV50  NOTIFICATION-GROUP 
   NOTIFICATIONS {
      envPowerSupplyFailed,
      envPowerSupplyRecovered,
      envFanFailed,
      envFanRecovered,
      envTempExceeded,
      envTempNormal,
      envHotSwapIn,
      envHotSwapOut,
      envBackupControlModuleOnline,
      envBackupControlModuleFailure,
      envLineModuleFailure,
      envCPUThresholdExceeded,
      polAclDenied
}
 STATUS current
 DESCRIPTION
  "A set of managed objects that make up version 5.0 of the SSR Trap MIB."
    ::= { ssrTrapsGroups 5 } 

END