AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTRON-WAN-MIB

CTRON-WAN-MIB device MIB details by Enterasys Networks Inc

CTRON-WAN-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-WAN-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-WAN-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTRON-WAN-MIB DEFINITIONS ::= BEGIN

        --  CTRON-WAN-MIB  The Cabletron Wide area MIB.
        --  Revision: 01.08.06
        --  Part Number: 2170989
        --  Date:  May 20, 1998

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for part
        --  of the naming tree below:
        --
        --              cabletron { enterprises 52 }
        --
        --  This module will be extended, as additional sub-sections
        --  of this naming tree are defined.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems


    IMPORTS
            OBJECT-TYPE             FROM RFC-1212
            ctWan                   FROM CTRON-MIB-NAMES
            DisplayString           FROM RFC1213-MIB
            IpAddress, Counter      FROM RFC1155-SMI;

         -- variables
                Index ::= INTEGER
                DLCI  ::= INTEGER
                -- DisplayString            ::= OCTET STRING

--====================================================================
    -- Groups

    ctWanConnection OBJECT IDENTIFIER   ::= { ctWan 1 }

    ctWanDs1        OBJECT IDENTIFIER   ::= { ctWan 2 }

    ctWanRs232      OBJECT IDENTIFIER   ::= { ctWan 3 }

    ctFrDcp         OBJECT IDENTIFIER   ::= { ctWan 4 }

    ctDDS           OBJECT IDENTIFIER   ::= { ctWan 5 }

    ctDs1Alarms     OBJECT IDENTIFIER   ::= { ctWan 6 }

    ctIPPQFilters  OBJECT IDENTIFIER   ::= { ctWan 7 }

    ctWanHDSLExt    OBJECT IDENTIFIER   ::= { ctWan 8 }

--  ctWanConnection Group
--  This group is mandatory for all platforms that have one or more
--  Wan Connections

    wanNumConnections OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This objects describes the number of wan connections on the
                platform. A wan connection may have one or two physical ports
                of which only one can be active at any time."
        ::= { ctWanConnection 1 }

    wanConnTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF WanConnEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A list of wan connection entries. The number of wan
                connection entries is given by the value of wanNumConnections."
        ::= { ctWanConnection 2 }

    wanConnEntry OBJECT-TYPE
        SYNTAX  WanConnEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A wan connection entry containing objects relating to
                the particular wan connection."
        INDEX { wanConnIndex }
        ::= { wanConnTable 1 }

    WanConnEntry ::=
        SEQUENCE {
            wanConnIndex
                INTEGER,
            wanConnNumPhysPorts
                INTEGER,
            wanConnDefaultPhysPort
                INTEGER,
            wanConnActivePhysPort
                INTEGER
            }

    wanConnIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A unique value for each wan connection. Its value ranges
                between 1 and the value wanNumConnections."
        ::= { wanConnEntry 1 }

    wanConnNumPhysPorts  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of physical ports that exist on this wan
                 connection."
        ::= { wanConnEntry 2 }

    wanConnDefaultPhysPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The default physical port for this connection.  This
                indicates the physical port that should be used on this wan
                connection. If redundancy is not enabled, this physical port
                will always be used. If redundancy is enabled, the physical
                port given here will be considered the primary physical port.
                The value of this object must be set to the index of a
                valid physical port (wanPhysPortIndex) for this wan connection."
        ::= { wanConnEntry 3 }

    wanConnActivePhysPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The physical port that is currently active for this wan
                connection. The value of this object indicates the
                wanPhysPortIndex for the active port."
        ::= { wanConnEntry 4 }


    wanPhysPortTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF WanPhysPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A list of the descriptions of the physical ports of this
                 platform. The number of entries is given by the value
                 of wanConnNumPhysPort for each Wan Connection."
        ::= { ctWanConnection 3 }

    wanPhysPortEntry OBJECT-TYPE
        SYNTAX  WanPhysPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A physical port entry. It contains objects relating to a
                given physical port"
        INDEX   { wanPhysPortConnectionIndex, wanPhysPortIndex }
        ::= { wanPhysPortTable 1 }

    WanPhysPortEntry ::=
        SEQUENCE {
            wanPhysPortConnectionIndex
                INTEGER,
            wanPhysPortIndex
                INTEGER,
            wanPhysPortType
                INTEGER,
            wanPhysPortSpecificMib
                OBJECT IDENTIFIER
            }

    wanPhysPortConnectionIndex  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A value indicating the wan connection this physical port
                is located on."
        ::= { wanPhysPortEntry 1 }

    wanPhysPortIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A unique value for each physical port on a wan connection.
                Its value ranges between 1 and the value wanConnNumPhysPorts."
        ::= { wanPhysPortEntry 2 }

    wanPhysPortType OBJECT-TYPE
        SYNTAX  INTEGER {
                none(1),
                t1(2),
                e1(3),
                synchronous(4),
                dds(5),
                di(6),
                hdsl(7),
                bri(8),
                ds30(9),
                t1DDS(10)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The type of physical port that this entry describes. None
                indicates that the physical port has no connector."
        ::= { wanPhysPortEntry 3 }

    wanPhysPortSpecificMib OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "This object identifies an instance of the index object in
         the first group of objects in the MIB specific to the
         physical port."
        ::= { wanPhysPortEntry 4 }

    wanInterfaceTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF WanInterfaceEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "The interface table for a physical port on a wan connection.
                It is a list of items that are pertinent to the interfaces
                that are part of this physical port. The number of entries
                is dependent on the wanPhysPortType for the interface.
                If the wanPhysPortType is none, there will be no entries
                in the table for the port. If the wanPhysPortType is t1,
                there will be 24 entries in this table for the port.
                If the wanPhysPortType is e1, there will be 30 entries
                in this table for the port. If the wanPhysPortType is
                synchronous, there will be one entry in this table for the
                port. "
        ::= { ctWanConnection 4 }

    wanInterfaceEntry OBJECT-TYPE
        SYNTAX  WanInterfaceEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A wan connection physical port interface entry. It
                contains objects relating to an interface that is defined
                for this physical port and this wan connection."
        INDEX   { wanInterfaceConnectionIndex, wanInterfacePhysPortIndex,
                wanInterfaceEntryIndex }
        ::= { wanInterfaceTable 1}

    WanInterfaceEntry  ::=
        SEQUENCE {
            wanInterfaceConnectionIndex
                INTEGER,
            wanInterfacePhysPortIndex
                INTEGER,
            wanInterfaceEntryIndex
                INTEGER,
            wanInterfaceEntryIfIndex
                INTEGER,
            wanInterfaceEntryProtocol
                INTEGER,
            wanInterfaceEntryCompression
                INTEGER,
            wanInterfaceEntryMTU
                INTEGER,
            wanInterfaceEntryLineCoding
                INTEGER,
            wanInterfaceEntryCrcLength
                INTEGER,
            wanInterfaceEntryLexProtocolEnable
                INTEGER,
            wanInterfaceEntryLexProtocolStatus
                INTEGER,
            wanInterfaceEntryCompRatio
                OCTET STRING,
            wanInterfaceEntryCompStatus
                INTEGER,
            wanInterfaceEntryBackUpIfEnable
                INTEGER
            }
    wanInterfaceConnectionIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This value is the wan connection that this interface
                 exists on."
        ::= { wanInterfaceEntry 1}

    wanInterfacePhysPortIndex   OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This value is the physical port of the wan connection
                that this interface exists on."
        ::= { wanInterfaceEntry 2}

    wanInterfaceEntryIndex  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A unique value for each interface of this physical port.
                It is a value between 1 and the number of interfaces that
                exist for the current port. The number of interfaces for
                each type of port is: 24 for a port type (wanPhysPortType)
                of 't1', 30 for a port type of 'e1',  and 1 for a port type
                of 'synchronous'. There will be no entries if the port type
                is 'none'."
        ::= { wanInterfaceEntry 3}

    wanInterfaceEntryIfIndex    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex of the interface. This is the index of this entry
                in the ifTable."
        REFERENCE
                "rfc-1213"
        ::= { wanInterfaceEntry 4}

    wanInterfaceEntryProtocol   OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The protocol that should be run on this interface. Values
                are equivalent to those defined for ifType in Mib-II.
                Accepted values are product dependent."
        REFERENCE
                "rfc-1213, product literature"
        ::= { wanInterfaceEntry 5}

    wanInterfaceEntryCompression    OBJECT-TYPE
        SYNTAX  INTEGER {
                on(1),
                off(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Indicates whether data compression should take
                place on this interface."
        ::= { wanInterfaceEntry 6}

    wanInterfaceEntryMTU    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
         DESCRIPTION
                "The MTU to be negotiated for this interface. This will not
                be updated with the actual MTU, which can be found in the
                ifTable."
        ::= { wanInterfaceEntry 7}

    wanInterfaceEntryLineCoding OBJECT-TYPE
        SYNTAX  INTEGER {
                none (1),
                jBZS (2),
                invHDLC (3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object describes the variety of Zero Code suppression
                on this interface. For an interface on a Ds1 Port, the valid
                values depend on the value of the Ds1ConfigLineCode object.
                If that object is set to ds1xB8ZS, then this object can be
                set to none, JBZS, or InvHDLC. If the value of
                Ds1ConfigLineCode is set to ds1xAMI, then this object can
                only be set to JBZS, or InvHDLC.  For an interface on a
                Synchronous Port, the valid values are none or InvHDLC.
                JBZS refers to Jammed Bit Zero suppression, which forces a
                1 bit every 8 bit periods. InvHDLC refers to inverting
                the HDLC data for the interface. None refers to a mode
                in which some other means, such as with the Ds1ConfigLineCode
                object set to dsx1B8ZS, is used to insure pulse density
                requirements."
        REFERENCE
                "rfc-1406"
        ::= { wanInterfaceEntry 8}

    wanInterfaceEntryCrcLength  OBJECT-TYPE
        SYNTAX  INTEGER {
                sixteen-bits(1),
                thirty-two-bits(2)
                }       
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Length of the CRC for this interface. Not all platforms
                will allow all options."
        ::= { wanInterfaceEntry 9}

    wanInterfaceEntryLexProtocolEnable  OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
                }
        ACCESS  read-write
        STATUS  deprecated
        DESCRIPTION
                "This switch acts in concert with the wanInterfaceEntryProtocol
                object.  To activate LEX, this object should first be set to
                enable (1), then set the wanInterfaceEntryProtocol to PPP.  The 
                enable will have no effect if PPP is not selected.  If the
                wanInterfaceEntryProtocol is selected first, the default NCP of
                BNCP will be selected.  To De-select LEX, you must set this 
                object to disable (2), and wanInterfaceEntryProtocol to NONE or
                reset the device.  Just selecting disable (2) will not tear down
                the connection."
        ::= { wanInterfaceEntry 10}
    
    wanInterfaceEntryLexProtocolStatus  OBJECT-TYPE
        SYNTAX  INTEGER {
                bound (1),
                unbound (2)
                }
        ACCESS  read-only
        STATUS  deprecated
        DESCRIPTION
                "This object reflects the current state of the link.  The device
                is said to be bound to the router when the physical link is OK,
                the LEX negotiation is successful, and the router has been
                configured correctly to communicate with this particular LAN
                Extender."
        ::= { wanInterfaceEntry 11}

    wanInterfaceEntryCompRatio    OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (6))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ratio of uncompressed to compressed transmitted data. 
                If the data compression status is off, 1:1 will be displayed"

        ::= { wanInterfaceEntry 12}

    wanInterfaceEntryCompStatus    OBJECT-TYPE
        SYNTAX  INTEGER {
                on(1),
                off(2)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "On indicates that the compression has been successfully
                 negotiated and is operating. Off indicates that the
                 compression negotiation has failed and compression is not
                 operating at this time, or compression has been terminated
                 by either peer."
        ::= { wanInterfaceEntry 13}

wanInterfaceEntryBackUpIfEnable    OBJECT-TYPE
        SYNTAX  INTEGER {
                enable (1),
                disable (2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object is used to select the Call-backup option.
                 A value of 1 is used to enable the option and a value of
                 2 to disable it."
        ::= { wanInterfaceEntry 14}

-- Wan Ds1 Group
-- This group is required for any platforms that have a t1 or e1 physical port.
--
    wanDs1ExtensionsTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF WanDs1ExtensionsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table is an extension to the standard ds1 configuration
                table. It is a list of items that are pertinent to ds1 ports
                on a platform. There is one entry per ds1 physical port on
                the platform"
        ::= { ctWanDs1 1 }

    wanDs1ExtensionsEntry OBJECT-TYPE
        SYNTAX  WanDs1ExtensionsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A ds1 extensions entry containing objects relating to
                 the particular ds1 physical port"
        INDEX   { wanDs1ExtensionsEntryIndex }
        ::= { wanDs1ExtensionsTable 1 }

    WanDs1ExtensionsEntry ::=
        SEQUENCE {
            wanDs1ExtensionsEntryIndex
                INTEGER,
            wanDs1ExtensionsNumInterfaces
                INTEGER,
            wanDs1ExtensionsToggleFracTable
                INTEGER,
            wanDs1ExtensionsLineBuildOut
                INTEGER,
            wanDs1ExtensionsCFADuration
                INTEGER,
            wanDs1ExtensionsDIEnable
                INTEGER,
            wanDs1ExtensionsTotalValidIntervals
                Counter,
            wanDs1ExtensionsBertTestMode
                INTEGER,
            wanDs1ExtensionsBertRun
                INTEGER,
            wanDs1ExtensionsBertCurrentResults
                INTEGER,
            wanDs1ExtensionsBertCumulativeResults
                INTEGER,
            wanDs1ExtensionsBertPeakResults
                INTEGER,
            wanDs1ExtensionsBertAverageResult
                INTEGER,
            wanDs1ExtensionsBertTestPattern
                INTEGER,
            wanDs1ExtensionsBertSamplePeriod
                INTEGER,
            wanDs1ExtensionsBertNumPeriods
                Counter,
            wanDs1ExtensionsBertTestTraps
                INTEGER,
            wanDs1ExtensionsBertDataStatus
                INTEGER
            }

    wanDs1ExtensionsEntryIndex  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A unique value for each ds1 physical port on the platform."
        ::= { wanDs1ExtensionsEntry 1 }

    wanDs1ExtensionsNumInterfaces       OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of interfaces on this physical port. This
                number indicates the number of  entries this physical port
                uses in the ifTable."
        REFERENCE
                "rfc-1213"
        ::= { wanDs1ExtensionsEntry 2 }

    wanDs1ExtensionsToggleFracTable     OBJECT-TYPE
        SYNTAX  INTEGER {
                update-table(1),
                display-new(2),
                display-old(3),
                restore-old(4)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Setting this object to 1 will cause the Ds1 Fractional Table
                 to be updated with the new values, as entered.
                 Setting this object to 2, will cause the Ds1 Fractional Table
                 to view as the table being entered.
                 Setting this object to 3, will cause the Ds1 Fractional Table
                 to be the table that is currently in use, regardless of
                 any changes being entered.
                 Setting this object to 4, will cause any changes that have
                 been made to the Ds1 Fractional Table since the last
                 update-table to be deleted.
                 For physical ports of type synchronous, this object will
                 have no affect, and will always return a 1."
        REFERENCE
                "rfc-1406"
        ::= { wanDs1ExtensionsEntry 3 }

    wanDs1ExtensionsLineBuildOut        OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                zero(2),
                minus-7point5(3),
                minus-15(4),
                a133to266feet(5),
                a266to399feet(6),
                a399to533feet(7),
                a533to655feet(8)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The line build out setting for this ds1 physical port.
                Unknown indicates that the setting is neither readable or
                writable."
        ::= { wanDs1ExtensionsEntry 4 }

    wanDs1ExtensionsCFADuration OBJECT-TYPE
        SYNTAX  INTEGER(1..15)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The length of time (in seconds), that the ds1 port will
                remain in the Carrier Failure Alarm state after the
                alarm condition has cleared."
    ::= { wanDs1ExtensionsEntry 5 }

    wanDs1ExtensionsDIEnable    OBJECT-TYPE
        SYNTAX  INTEGER{
                enable(1),
                disable(2),
                diDataEnabled(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Enables or disables Drop and Insert functionality on a
                D/I WPIM.  If enabled, all zero assigned timeslots will 
                designate D/I interface channels, if disabled all zero 
                channels will designate dummy channels as on a T1 or E1.
                If this object is set to diDataEnabled the zero channels
                will designate D/I interface channels and data to and
                from the device will be transmitted or received on the
                D/I port instead of the N/I port."
        ::= { wanDs1ExtensionsEntry 6 }

    wanDs1ExtensionsTotalValidIntervals OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of  previous  intervals  for  which
                valid data was collected for the DS1 mib, which
                is currently RFC1406.  This counter is similar to
                RFC1406 dsx1ValidIntervals except that the count
                represents the total number of complete 15 minute
                intervals since the ds1 interface has been online,
                and does not stop at the 24 hour period."
        ::= { wanDs1ExtensionsEntry 7 }

    wanDs1ExtensionsBertTestMode        OBJECT-TYPE
        SYNTAX  INTEGER{
        none(1),
        internal(2),
        manual(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object is used to request that a type of
                process be in control of the testing function.
                This is used to differentiate between automated test 
                procedures and those manually controlled by a user.  
                When read, this object reflects which type of process 
                is actually in control of the testing function.  The 
                implementation is free to prioritize or deny requests
                in a proprietary manner."
        ::= { wanDs1ExtensionsEntry 8 }

    wanDs1ExtensionsBertRun   OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS      read-write
        STATUS      mandatory
        DESCRIPTION
                "Controls the sending of test data over this physical 
                port.  The data is a pattern described by 
                wanDs1ExtensionsBertTestPattern." 
        ::= { wanDs1ExtensionsEntry 9 }

    wanDs1ExtensionsBertCurrentResults   OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                "Indicates the results of the testing for the
                last completed sampling period.  A non-negative
                number is the error rate in bits per million bits."
        ::= { wanDs1ExtensionsEntry 10 }

    wanDs1ExtensionsBertCumulativeResults   OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                "Indicates the total number of errors since the
                testing was enabled.  It is not a rate."
        ::= { wanDs1ExtensionsEntry 11 }

    wanDs1ExtensionsBertPeakResults   OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                "Indicates the highest value of 
                wanDs1ExtensionsBertCurrentResults since the testing 
                was enabled.  A non-negative number is the error rate 
                in bits per million bits." 
        ::= { wanDs1ExtensionsEntry 12 }

    wanDs1ExtensionsBertAverageResult   OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                "Indicates the average value of 
                wanDs1ExtensionsBertCurrentResults since the testing 
                was enabled.  A non-negative number is the error rate 
                in bits per million bits." 
        ::= { wanDs1ExtensionsEntry 13 }

    wanDs1ExtensionsBertTestPattern     OBJECT-TYPE
        SYNTAX  INTEGER {
                patternOther(1),
                pattern1s(2),
                pattern63(3),
                pattern511(4),
                pattern2047(5),
                pattern3in24(6),
                patternQRSS(7)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object is used to specify the pattern of the 
                test data."
        ::= { wanDs1ExtensionsEntry 14 }

    wanDs1ExtensionsBertSamplePeriod    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object is the duration of time in seconds at
                which the current test results will be periodically
                written to wanDs1ExtensionsBertCurrentResults.  The 
                range is 1 to 3600, with a default value of 10."
        ::= { wanDs1ExtensionsEntry 15 }

    wanDs1ExtensionsBertNumPeriods   OBJECT-TYPE
        SYNTAX  Counter
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                " The number of sampling periods that have elapsed
                during the current test run."
        ::= { wanDs1ExtensionsEntry 16 }

    wanDs1ExtensionsBertTestTraps       OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object is used to enable or disable the sending
                of a trap at the conclusion of the measurement period.
                The trap will contain the information described by
                ctDs1BertCurrentResults.  The default value is disabled."
        ::= { wanDs1ExtensionsEntry 17 }

    wanDs1ExtensionsBertDataStatus   OBJECT-TYPE
        SYNTAX  INTEGER {
                idle(1),
                waitingForLink(2),
                waitingForLoopback(3),
                running(4)
                }
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
                "This object provides the operating status of the
                transmission of test data packets."
        ::= { wanDs1ExtensionsEntry 18 }

-- Wan  Rs232 Group
--  This group is only required if any physical port on the system can be
--  classified as rs232-like
--
    wanRs232ExtensionsTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF WanRs232ExtensionsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table is an extension to the standard rs232-like mib.
                It is a list of items that are pertinent to rs232-like ports
                on a platform. There is one entry per synchronous physical
                port on the platform."
        REFERENCE
                "rfc-1317"
        ::= { ctWanRs232 1 }

    wanRs232ExtensionsEntry OBJECT-TYPE
        SYNTAX  WanRs232ExtensionsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A rs232-like extensions entry containing objects relating to
                the particular rs232-like physical port."
        INDEX   { wanRs232ExtensionsEntryIndex }
        ::= { wanRs232ExtensionsTable 1 }

    WanRs232ExtensionsEntry ::=
        SEQUENCE {
            wanRs232ExtensionsEntryIndex
                INTEGER,
            wanRs232ExtensionsCTSEnable
                INTEGER,
            wanRs232ExtensionsDSREnable
                INTEGER
            }

    wanRs232ExtensionsEntryIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A unique value for each rs232-like physical port on
                the platform."
        ::= { wanRs232ExtensionsEntry 1 }

    wanRs232ExtensionsCTSEnable OBJECT-TYPE
        SYNTAX  INTEGER {
                enable(1),
                disable(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                 "This object indicates whether the platform should generate
                CTS. When disabled the platform will not generate CTS, when
                enabled, the platform will generate CTS.  The actual state
                of the CTS line is available in the rs-232 like mib."
        REFERENCE
                "rfc-1317"
        DEFVAL { disable }
        ::= { wanRs232ExtensionsEntry 2 }

    wanRs232ExtensionsDSREnable OBJECT-TYPE
        SYNTAX  INTEGER {
                enable(1),
                disable(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object indicates whether the platform should generate
                DSR. When disabled the platform will not generate DSR, when
                enabled, the platform will generate DSR.  The actual state
                of the DSR line is available in the rs-232 like mib."
        REFERENCE
                "rfc-1317 "
        DEFVAL { disable }
        ::= { wanRs232ExtensionsEntry 3 }

--  ctFrDcp Group
--  This group is mandatory to support Data Compression Protocol 
--  (DCP following FRF.9) for per virtual circuit basis

    frDcpCircuitTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF FrDcpCircuitEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A table containing data compression information about 
                specific Data Link Connection Identifiers and corresponding
                virtual circuit. This information is used to support the
                frCircuitTable following RFC-1315."
        ::= { ctFrDcp 1 }

    frDcpCircuitEntry OBJECT-TYPE
        SYNTAX  FrDcpCircuitEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "The data compression information regarding a single Data 
                Link Connection Identifier."
        INDEX { frDcpCircuitIfIndex, frDcpCircuitDlci }
        ::= { frDcpCircuitTable 1 }

    FrDcpCircuitEntry ::=
        SEQUENCE {
            frDcpCircuitIfIndex
                 Index,
            frDcpCircuitDlci
                 DLCI,
            frDcpCircuitEnable
                 INTEGER,
            frDcpCircuitStatus
                 INTEGER,
            frDcpCircuitRatio
                 OCTET STRING
            }

    frDcpCircuitIfIndex OBJECT-TYPE
        SYNTAX  Index
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex value of ifEntry that this DCP virtual circuit 
                object is layered onto."
        ::= { frDcpCircuitEntry 1 }

    frDcpCircuitDlci OBJECT-TYPE
        SYNTAX  DLCI
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Data Link Connection Identifier for this DCP virtual 
                circuit object."
        REFERENCE
                "Draft American National Standard T1.618-1991, Section 3.3.6"
        ::= { frDcpCircuitEntry 2 }

    frDcpCircuitEnable OBJECT-TYPE
        SYNTAX  INTEGER {
                on (1),
                off (2)          -- default
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Indicates whether data compression should take place on
                this particular end side virtual circuit."
        ::= { frDcpCircuitEntry 3 }

    frDcpCircuitStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                on (1),
                off (2)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "On indicates that the compression has been successfully
                 negotiated and is operating. Off indicates that the
                 compression negotiation has failed and compression is not
                 operating at this time, or compression has been terminated
                 by either peer."
        ::= { frDcpCircuitEntry 4 }

    frDcpCircuitRatio OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (5))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ratio of uncompressed to compressed transmitted data. 
                If the data compression status is off, 1:1 will be displayed"
        ::= { frDcpCircuitEntry 5 }

--
-- Wan DDS Group
-- This group is required for any platforms that have a dds physical port.
--

ddsConfigTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DdsConfigEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "The DDS Configuration Table"
        ::= { ctDDS 1}

ddsConfigEntry  OBJECT-TYPE
        SYNTAX  DdsConfigEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "An Entry in the DDS Configuration Table"
        INDEX   { ddsLineIndex }
        ::= { ddsConfigTable 1 }

DdsConfigEntry ::=
        SEQUENCE {
            ddsLineIndex
                INTEGER,
            ddsIfIndex
                INTEGER,
            ddsLineMode
                INTEGER,
            ddsLineCoding
                INTEGER,
            ddsLoopbackConfig
                INTEGER,
            ddsLineStatus
                INTEGER,
            ddsTxClockSource
                INTEGER,
            ddsPortInSpeed 
                INTEGER,
            ddsPortOutSpeed
                INTEGER
            }

        ddsLineIndex OBJECT-TYPE
                SYNTAX  INTEGER (1..'7fffffff'h)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A unique value for each dds physical port on the 
                         platform"
                ::= { ddsConfigEntry 1 }

        ddsIfIndex OBJECT-TYPE
                SYNTAX  INTEGER (1..'7fffffff'h)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Index associated with this dds physical port"
                ::= { ddsConfigEntry 2 }

        ddsLineMode OBJECT-TYPE
                SYNTAX  INTEGER {
                        ddsPri (1),
                        ddsCc (2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "DDS-PRI is full duplex 56k link, No framing in loop 
                        data so loop speed is also 56k. Data stream:
                                --d1 d2 d3 d4 d5 d6 d7--        

                        DDS-CC is full duplex 64k link. Does not require framing
                        bit but uses a same format as SC, ninth bit position is 
                        lumped with primary channel and not used for control.
                        Loop speed is 72k, Primary channel rate is 64k.
                                --d1 d2 d3 d4 d5 d6 d7 F d8--"
                ::= { ddsConfigEntry 3 }

        ddsLineCoding OBJECT-TYPE
                SYNTAX  INTEGER {
                        ddsNone (1),
                        ddsJBZS (2),
                        otherLineCode (3)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "This object describes the variety of Zero Code 
                        suppression on this interface.  JBZS refers to Jammed 
                        Bit Zero suppression, which forces a 1 bit every 8 bit 
                        periods. None refers to a mode in which some other 
                        means is used to insure pulse density requirements."
                ::= { ddsConfigEntry 4 }

        ddsLoopbackConfig OBJECT-TYPE
                SYNTAX  INTEGER {
                        ddsNoLoop (1),
                        ddsLineLoop (2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "This variable represents the loop-back configuration 
                        of the DDS interface.  ddsNoLoop means the interface is
                        not in loop-back state, and LineLoop means the the
                        received data is looped back out."
                ::= { ddsConfigEntry 5 }

        ddsLineStatus OBJECT-TYPE
                SYNTAX  INTEGER {
                        ddsNoAlarm (1),
                        ddsLossOfSignal (2),
                        ddsOutOfService (3),
                        ddsOutOfFrame (4)
                        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This describes the current operational
                        status of DDS line."
                ::= { ddsConfigEntry 6 }        

        ddsTxClockSource OBJECT-TYPE
                SYNTAX  INTEGER {
                        ddsLoopTiming (1),
                        ddsLocalTiming (2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The source of Transmit clock.
                        ddsLoopTiming - indicates that the recovered receive 
                        clock is used as transmit clock.
                        ddsLocalTiming - indicates that a local clock source is
                        used."
                ::= { ddsConfigEntry 7 }

        ddsPortInSpeed OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        " This variable describes the current operational 
                         receive speed of DDS line.  It is a read only value
                         based entirely on DDS type (CC or PRI)."
                ::= { ddsConfigEntry 8 }        
        
        ddsPortOutSpeed OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This variable describes the current operational
                         transmit speed of DDS line.  It is a read only value
                         based entirely on DDS type CC or PRI"
                ::= { ddsConfigEntry 9 }        

--
-- Wan Alarms Group
-- This group is required for any platforms that support
-- Cabletron's WAN Alarm processing functionality
--

--
-- DS1 Alarms Global Configuration Variables
--
--      These parameters apply globally to the DS1 Alarms
--      entity.  These variables allow the user to program
--      DS1 alarm characteristics to be the same for all DS1
--      lines installed in the device.  The other option
--      available to the user would be to configure each DS1
--      line individually, using the parameters in the DS1
--      Alarms Configuration Table.
--

        ds1AlarmsGlobalConfigGroup OBJECT IDENTIFIER ::= { ctDs1Alarms 1 }

        ds1AlarmGlobalAdmin     OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),    -- default
                        enabled(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        Monitoring Application for all DS1 circuits on the 
                        device."
                ::= { ds1AlarmsGlobalConfigGroup 1}

        ds1AlarmGlobalAutoRecovery      OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),
                        enabled(2)      -- default
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        Automatic Recovery feature for all DS1 circuits on 
                        the device. For those devices that support ds1
                        alarm monitoring, but do not support the automatic
                        recovery feature, this object always returns disabled,
                        and performs no action when written."
                ::= { ds1AlarmsGlobalConfigGroup 2}

        ds1AlarmGlobalTrapEnable        OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),
                        enabled(2)      -- default
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        SNMP Trap generation feature for all DS1 circuits on 
                        the device.  This object operates in conjunction with 
                        configuration of objects in the ctron-trap-mib.txt"
                ::= { ds1AlarmsGlobalConfigGroup 3}

        ds1AlarmGlobalESCount   OBJECT-TYPE
                SYNTAX  INTEGER (1..300)        -- default is 100
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used in conjuction with ctDs1AlarmESInterval to set 
                        the threshold for alarm generation when the number of 
                        Errored Seconds for a specified time interval, 
                        measured in minutes, is exceeded.  The default 
                        Errored Seconds alarm condition is 100 errored seconds 
                        over a 6 minute time interval."
                ::= { ds1AlarmsGlobalConfigGroup 4}

        ds1AlarmGlobalESInterval        OBJECT-TYPE
                SYNTAX  INTEGER (1..15) -- default is 6 minutes
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used in conjuction with ds1AlarmGlobalESCount to 
                        set the threshold for alarm generation when the number 
                        of Errored Seconds for a specified time interval, 
                        measured in minutes, is exceeded.  The default
                        Errored Seconds alarm condition is 100 errored seconds 
                        over a 6 minute time interval."
                ::= { ds1AlarmsGlobalConfigGroup 5}

        ds1AlarmGlobalBPVErrorRate      OBJECT-TYPE 
                SYNTAX  INTEGER (5..9)  -- default is 6
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to specify the negative exponent of 10, used in
                        monitoring Bipolar Violations (Code Violations for E1)
                        over intervals defined by ds1AlarmGlobalBPVInterval.  
                        For example, for a ds1AlarmGlobalBPVErrorRate value 
                        of 6 used with a ds1AlarmGlobalBPVInterval of 15, 
                        an alarm is generated when a 15 minute period has an 
                        average error rate which exceeds 1 Bipolar Violation 
                        (Code Violation for E1) per million bits.
                        For those devices that support ds1 alarm monitoring
                        but who's hardware does not support detect bipolar
                        violations, this object always returns the default,
                        and performs no action when written."
                ::= { ds1AlarmsGlobalConfigGroup 6}

        ds1AlarmGlobalBPVInterval       OBJECT-TYPE
                SYNTAX  INTEGER (1..15) -- default is 15 minutes
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to specify the interval, used in monitoring 
                        Bipolar Violations (Code Violations for E1)
                        with thresholds defined by ds1AlarmGlobalBPVErrorRate.
                        For example, for a ds1AlarmGlobalBPVErrorRate value 
                        of 6 used with a ds1AlarmGlobalBPVInterval of 15, an 
                        alarm is generated when a 15 minute period has an 
                        average error rate which exceeds 1 Bipolar Violation 
                        (Code Violation for E1) per million bits.
                        For those devices that support ds1 alarm monitoring
                        but who's hardware does not detect bipolar
                        violations, this object always returns the default,
                        and performs no action when written."
                ::= { ds1AlarmsGlobalConfigGroup 7}

        ds1AlarmGlobalManualRecovery    OBJECT-TYPE
                SYNTAX  INTEGER {
                        recover(1)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "To cause a manual recovery to occur on all Ds1 circuits, this
                        object is set to a 1.  It is always read as a 1.  The recovery 
                        will occur only when automatic recovery is disabled."
                ::= { ds1AlarmsGlobalConfigGroup 8}

--
-- DS1 Alarms Configuration Table
--
--      The DS1 alarm table structure contains the same information as the
--      global configuration objects, but allows seperate configuratoin of 
--      specific DS1 circuits contained on the device
--
        ds1AlarmConfigTable OBJECT-TYPE
                SYNTAX      SEQUENCE OF Ds1AlarmConfigEntry
                ACCESS      not-accessible
                STATUS      mandatory
                DESCRIPTION
                        "Table containing objects used to configure DS1 alarm 
                        functionality on a per DS1 basis."
                ::= { ctDs1Alarms 2 }
        
        ds1AlarmConfigEntry OBJECT-TYPE
                SYNTAX      Ds1AlarmConfigEntry
                ACCESS      not-accessible
                STATUS      mandatory
                DESCRIPTION
                        "A description of a single entry."
                INDEX       { ds1PhysNum }
                ::= { ds1AlarmConfigTable 1 }
        
        Ds1AlarmConfigEntry ::=
                SEQUENCE {
                        ds1PhysNum
                        INTEGER,
                        ds1AlarmAdmin
                        INTEGER,
                        ds1AlarmAutoRecovery
                        INTEGER,
                        ds1AlarmTrapEnable
                        INTEGER,
                        ds1AlarmESCount
                        INTEGER,
                        ds1AlarmESInterval
                        INTEGER,
                        ds1AlarmBPVErrorRate
                        INTEGER,
                        ds1AlarmBPVInterval
                        INTEGER,
                        ds1AlarmManualRecovery
                        INTEGER
                        }
        
        ds1PhysNum    OBJECT-TYPE
                SYNTAX      INTEGER
                ACCESS      read-only
                STATUS      mandatory
                DESCRIPTION
                        "The value for this object is equal to the value
                        of a unique physical connection identifier associated
                        with this DS1 which is clearly labeled on the device.
                        For those products that do not have a DS1 identifier
                        labeled on the device, the value for this object is
                        the same as rfc1406 dsx1LineIndex."
                ::= { ds1AlarmConfigEntry 1 }
        
        ds1AlarmAdmin   OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),    -- default
                        enabled(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        Monitoring Application for this DS1 circuit."
                ::= { ds1AlarmConfigEntry 2}

        ds1AlarmAutoRecovery    OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),
                        enabled(2)      -- default
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        Automatic Recovery feature for this DS1 circuit.
                        For those devices that support ds1
                        alarm monitoring, but do not support the automatic
                        recovery feature, this object always returns disabled,
                        and performs no action when written."
                ::= { ds1AlarmConfigEntry 3}

        ds1AlarmTrapEnable      OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),
                        enabled(2)      -- default
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the DS1 Alarm
                        SNMP Trap generation feature for this DS1 circuit.
                        This object operates in conjunction with configuration 
                        of objects in the ctron-trap-mib.txt"
                ::= { ds1AlarmConfigEntry 4}

        ds1AlarmESCount OBJECT-TYPE
                SYNTAX  INTEGER (1..300)        -- default is 100
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used in conjuction with ctDs1AlarmESInterval to set 
                        the threshold for alarm generation when the number of 
                        Errored Seconds for a specified time interval, measured 
                        in minutes, is exceeded.  The default Errored Seconds 
                        alarm condition is 100 errored seconds over a 6 minute
                        time interval."
                ::= { ds1AlarmConfigEntry 5}

        ds1AlarmESInterval      OBJECT-TYPE
                SYNTAX  INTEGER (1..15) -- default is 6 minutes
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used in conjuction with ctDs1AlarmESCount to set the 
                        threshold for alarm generation when the number of 
                        Errored Seconds for a specified time interval, measured 
                        in minutes, is exceeded.  The default Errored Seconds 
                        alarm condition is 100 errored seconds over a 6 minute 
                        time interval."
                ::= { ds1AlarmConfigEntry 6}

        ds1AlarmBPVErrorRate    OBJECT-TYPE
                SYNTAX  INTEGER (5..9)  -- default is 6
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to specify the negative exponent of 10, used in
                        monitoring Bipolar Violations (Code Violations for E1)
                        over intervals defined by ds1AlarmBPVInterval.  For 
                        example, for a ds1AlarmBPVErrorRate value of 6 used 
                        with a ds1AlarmBPVInterval of 15, an alarm is generated 
                        when a 15 minute period has an average error rate which 
                        exceeds 1 Bipolar Violation (Code Violation for E1) per
                        million bits.
                        For those devices that support ds1 alarm monitoring
                        but who's hardware does not support detect bipolar
                        violations, this object always returns the default,
                        and performs no action when written."
                ::= { ds1AlarmConfigEntry 7}

        ds1AlarmBPVInterval     OBJECT-TYPE
                SYNTAX  INTEGER (1..15) -- default is 15 minutes
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to specify the interval, used in
                        monitoring Bipolar Violations (Code Violations for E1)
                        with thresholds defined by ds1AlarmBPVErrorRate.  For 
                        example, for a ds1AlarmBPVErrorRate value of 6 used 
                        with a ds1AlarmBPVInterval of 15, an alarm is generated 
                        when a 15 minute period has an average error rate
                        which exceeds 1 Bipolar Violation (Code Violation for 
                        E1) per million bits.
                        For those devices that support ds1 alarm monitoring
                        but who's hardware does not support detect bipolar
                        violations, this object always returns the default,
                        and performs no action when written."
                ::= { ds1AlarmConfigEntry 8}

        ds1AlarmManualRecovery  OBJECT-TYPE
                SYNTAX  INTEGER {
                        recover(1)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "To cause a manual recovery to occur, this object is set
                        to a 1.  It is always read as a 1.  The recovery will 
                        occur only when automatic recovery is disabled."
                ::= { ds1AlarmConfigEntry 9}

--
-- Wan Internet Protocol Priority Queue Filters Group
-- This group is required for any platforms that support
-- Cabletron's WAN IP Priority Queue processing functionality
--

--
-- IP PQ Configuration Variables
--
--      These parameters apply to the IP Priority Queue
--      entity.  These variables allow the user to program
--      IP addresses in a filtering database.  The database
--      of IP addresses are used when a WAN service is over
--      subscribed, and the packet would normally be discarded.
--      If the IP PQ admin status is enabled, and the IP 
--      address of the packet to be discarded matches one
--      programmed in the database, an attempt will be made
--      to use high priority, reserved, resources to transmit
--      the packet.  The addresses programmed in this table
--      should be reserved for those packets which MUST be
--      transmitted.  Some examples would be RIP, and SNMP
--      packets, who's loss would cause major networking
--      problems for the system.
--

        ipPQConfigGroup OBJECT IDENTIFIER ::= { ctIPPQFilters 1 }

        ipPQAdmin       OBJECT-TYPE
                SYNTAX  INTEGER {
                        disabled(1),    -- default
                        enabled(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Used to enable and disable the IP Priority Queue
                        Forwarding Application."
                ::= { ipPQConfigGroup 1}

        iPPQMaxEntries  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Returns the maximum number of IP address entries 
                        supported by the IP Priority Queue application on 
                        this device."
                ::= { ipPQConfigGroup 2}

        iPPQNumEntries  OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Get the number of IP address entries currently
                        programmed in the ipPQAddressTable."
                ::= { ipPQConfigGroup 3}

        iPPQAddAddress OBJECT-TYPE
                SYNTAX      IpAddress
                ACCESS      read-write
                STATUS      mandatory
                DESCRIPTION
                        "Add an IP address to the ipPQAddressTable. Always
                        read as a 0.0.0.0."
                ::= { ipPQConfigGroup 4 }
          
        iPPQDelAddress OBJECT-TYPE
                SYNTAX      IpAddress
                ACCESS      read-write
                STATUS      mandatory
                DESCRIPTION
                        "Delete an IP address from the ipPQAddressTable.
                        Always read as a 0.0.0.0."
                ::= { ipPQConfigGroup 5 }
          
--
--
--
-- IP Priority Queue Address Table
--
--      The IP PQ table contains a list of IP adresses used with the 
--      Priority Queue filtering mechanism. 
--
        ipPQAddressTable OBJECT-TYPE
                SYNTAX      SEQUENCE OF IpPQAddressEntry
                ACCESS      not-accessible
                STATUS      mandatory
                DESCRIPTION
                        "Table containing IP addresses, used in an
                        IP Priority Queue Forwarding function."
                ::= { ctIPPQFilters 2 }
        
        ipPQAddressEntry OBJECT-TYPE
                SYNTAX      IpPQAddressEntry
                ACCESS      not-accessible
                STATUS      mandatory
                DESCRIPTION
                        "A description of a single entry."
                INDEX       { ipPQAddressId }
                ::= { ipPQAddressTable 1 }
        
        IpPQAddressEntry ::=
                SEQUENCE {
                        ipPQAddressId
                        INTEGER,
                        ipPQIPAddress
                        IpAddress
                        }
        
        ipPQAddressId    OBJECT-TYPE
                SYNTAX      INTEGER (1..65535)
                ACCESS      read-only
                STATUS      mandatory
                DESCRIPTION
                        "A unique value identifying an element in a sequence
                        of IP PQ address entries."
                ::= { ipPQAddressEntry 1 }
          
        ipPQIPAddress    OBJECT-TYPE
                SYNTAX      IpAddress
                ACCESS      read-only
                STATUS      mandatory
                DESCRIPTION
                        "Returns an IP address associated with a specific
                        entry in this table."
                ::= { ipPQAddressEntry 2 }

    --
    -- HDSL 15 Minute Performance History Table
    -- This group provides counters for UnAvailable Seconds and
    -- Errored Seconds of all HDSL connections
    --

    ctWanHDSLPerformance15mTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLPerformance15mEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "HDSL 15 minute performance table. This table provides the 
             accumulated counts of errored seconds (ES) and unavailable 
             seconds (UAS) for the HDSL line including the local, remote
             units and any doublers in between during a 15 minutes period
             for the last 24 hours. 

             The table is indexed by the non-empty slot in the device and
             the 15-minute history slot within the last 24 hours period."  
        ::= { ctWanHDSLExt 1 }

    ctWanHDSLPerformance15mEntry OBJECT-TYPE
        SYNTAX    CtWanHDSLPerformance15mEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries in the 15 minute performance table"
        INDEX
            { ctWanHDSLPerformance15mConnIndex, ctWanHDSLPerformance15mSlotIndex }
        ::= { ctWanHDSLPerformance15mTable 1 }

    CtWanHDSLPerformance15mEntry ::= SEQUENCE { 
        ctWanHDSLPerformance15mConnIndex
            INTEGER,
        ctWanHDSLPerformance15mSlotIndex
            INTEGER,
        ctWanHDSLHLULoop1UAS15m
            INTEGER,
        ctWanHDSLHLULoop1ES15m
            INTEGER,
        ctWanHDSLHLULoop2UAS15m
            INTEGER,
        ctWanHDSLHLULoop2ES15m
            INTEGER,
        ctWanHDSLHRULoop1UAS15m
            INTEGER,
        ctWanHDSLHRULoop1ES15m
            INTEGER,
        ctWanHDSLHRULoop2UAS15m
            INTEGER,
        ctWanHDSLHRULoop2ES15m
            INTEGER,
        ctWanHDSLDb1NetworkLoop1UAS15m
            INTEGER,
        ctWanHDSLDb1NetworkLoop1ES15m
            INTEGER,
        ctWanHDSLDb1NetworkLoop2UAS15m
            INTEGER,
        ctWanHDSLDb1NetworkLoop2ES15m
            INTEGER,
        ctWanHDSLDb1CustomerLoop1UAS15m
            INTEGER,
        ctWanHDSLDb1CustomerLoop1ES15m
            INTEGER,
        ctWanHDSLDb1CustomerLoop2UAS15m
            INTEGER,
        ctWanHDSLDb1CustomerLoop2ES15m
            INTEGER,
        ctWanHDSLDb2NetworkLoop1UAS15m
            INTEGER,
        ctWanHDSLDb2NetworkLoop1ES15m
            INTEGER,
        ctWanHDSLDb2NetworkLoop2UAS15m
            INTEGER,
        ctWanHDSLDb2NetworkLoop2ES15m
            INTEGER,
        ctWanHDSLDb2CustomerLoop1UAS15m
            INTEGER,
        ctWanHDSLDb2CustomerLoop1ES15m
            INTEGER,
        ctWanHDSLDb2CustomerLoop2UAS15m
            INTEGER,
        ctWanHDSLDb2CustomerLoop2ES15m
            INTEGER
         }
 
    ctWanHDSLPerformance15mConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify the HDSL connection within the device, indexing from
             1 to the maximum allowed number of HDSL connections in the
             device."
        ::= { ctWanHDSLPerformance15mEntry 1 }

    ctWanHDSLPerformance15mSlotIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Define which 15-minute slot history of the HDSL within the
             24 hour period. Indexing from 1 - 97 with the first index 
             representing the current 15-minute history"
        ::= { ctWanHDSLPerformance15mEntry 2 }
 
    --
    -- Local line unit's 15 minute performance history
    --

    ctWanHDSLHLULoop1UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the local line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 3 }

    ctWanHDSLHLULoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the local line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 4 }

    ctWanHDSLHLULoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the local line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 5 }

    ctWanHDSLHLULoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the local line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 6 }

    --
    -- Remote line unit's 15-minute performance history
    --

    ctWanHDSLHRULoop1UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 7 }

    ctWanHDSLHRULoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the remote line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 8 }

    ctWanHDSLHRULoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 9 }

    ctWanHDSLHRULoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the remote line unit during
             the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 10 }

    --
    -- Doubler 1's 15-minute performance history
    --

    ctWanHDSLDb1NetworkLoop1UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 11 }

    ctWanHDSLDb1NetworkLoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the first doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 12 }

    ctWanHDSLDb1NetworkLoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 13 }

    ctWanHDSLDb1NetworkLoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the first doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 14 }

    ctWanHDSLDb1CustomerLoop1UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 15 }

    ctWanHDSLDb1CustomerLoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the first doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 16 }

    ctWanHDSLDb1CustomerLoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 17 }

    ctWanHDSLDb1CustomerLoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the first doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 18 }

    --
    -- Doubler 2's 15-minute performance history
    --

    ctWanHDSLDb2NetworkLoop1UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 19 }

    ctWanHDSLDb2NetworkLoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the second doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 20 }

    ctWanHDSLDb2NetworkLoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 21 }

    ctWanHDSLDb2NetworkLoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the second doubler unit's
             network side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 22 }

    ctWanHDSLDb2CustomerLoop1UAS15m OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 23 }

    ctWanHDSLDb2CustomerLoop1ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the second doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 24 }

    ctWanHDSLDb2CustomerLoop2UAS15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 25 }

    ctWanHDSLDb2CustomerLoop2ES15m  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the second doubler unit's
             customer side during the 15-minute period."
        ::= { ctWanHDSLPerformance15mEntry 26 }

    --
    -- HDSL 24 hour Performance History Table 
    -- This group provides counters for UnAvailable Seconds and
    -- Errored Seconds of all HDSL connections
    --

    ctWanHDSLPerformance24hTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLPerformance24hEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "HDSL 24-hour performance table. This table provides the
             accumulated counts of errored seconds (ES) and unavailable
             seconds (UAS) for the HDSL line including the local, remote
             units and any doublers in between during a 24-hour period
             for the last 7 days.
 
             The table is indexed by the non-empty slot in the device and
             the 24-hour history slot within the last 7 days period."
        ::= { ctWanHDSLExt 2 }

    ctWanHDSLPerformance24hEntry  OBJECT-TYPE
        SYNTAX    CtWanHDSLPerformance24hEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries in the 24-hour ctWanHDSLPerformance table"
        INDEX
            { ctWanHDSLPerformance24hConnIndex, ctWanHDSLPerformance24hSlotIndex }
        ::= { ctWanHDSLPerformance24hTable 1 }

    CtWanHDSLPerformance24hEntry ::= SEQUENCE { 
        ctWanHDSLPerformance24hConnIndex
            INTEGER,
        ctWanHDSLPerformance24hSlotIndex
            INTEGER,
        ctWanHDSLHLULoop1UAS24h
            INTEGER,
        ctWanHDSLHLULoop1ES24h
            INTEGER,
        ctWanHDSLHLULoop2UAS24h
            INTEGER,
        ctWanHDSLHLULoop2ES24h
            INTEGER,
        ctWanHDSLHRULoop1UAS24h
            INTEGER,
        ctWanHDSLHRULoop1ES24h
            INTEGER,
        ctWanHDSLHRULoop2UAS24h
            INTEGER,
        ctWanHDSLHRULoop2ES24h
            INTEGER,
        ctWanHDSLDb1NetworkLoop1UAS24h
            INTEGER,
        ctWanHDSLDb1NetworkLoop1ES24h
            INTEGER,
        ctWanHDSLDb1NetworkLoop2UAS24h
            INTEGER,
        ctWanHDSLDb1NetworkLoop2ES24h
            INTEGER,
        ctWanHDSLDb1CustomerLoop1UAS24h
            INTEGER,
        ctWanHDSLDb1CustomerLoop1ES24h
            INTEGER,
        ctWanHDSLDb1CustomerLoop2UAS24h
            INTEGER,
        ctWanHDSLDb1CustomerLoop2ES24h
            INTEGER,
        ctWanHDSLDb2NetworkLoop1UAS24h
            INTEGER,
        ctWanHDSLDb2NetworkLoop1ES24h
            INTEGER,
        ctWanHDSLDb2NetworkLoop2UAS24h
            INTEGER,
        ctWanHDSLDb2NetworkLoop2ES24h
            INTEGER,
        ctWanHDSLDb2CustomerLoop1UAS24h
            INTEGER,
        ctWanHDSLDb2CustomerLoop1ES24h
            INTEGER,
        ctWanHDSLDb2CustomerLoop2UAS24h
            INTEGER,
        ctWanHDSLDb2CustomerLoop2ES24h
            INTEGER 
         }

    --
    -- Local line unit's 24-hour performance history
    --
 
    ctWanHDSLPerformance24hConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify the HDSL connection within the device, indexing from
             1 to the maximum allowed number of HDSL connections in the
             device."
        ::= { ctWanHDSLPerformance24hEntry 1 }

    ctWanHDSLPerformance24hSlotIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
           "Define which 24-hour slot history of the HDSL within the
             last 7 days period. Indexing from 1 - 8 with the first index
             representing the current 24 hour history"
        ::= { ctWanHDSLPerformance24hEntry 2 }
 
    ctWanHDSLHLULoop1UAS24h  OBJECT-TYPE
        SYNTAX     INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the local line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 3 }

    ctWanHDSLHLULoop1ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the local line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 4 }

    ctWanHDSLHLULoop2UAS24h  OBJECT-TYPE
        SYNTAX     INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the local line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 5 }

    ctWanHDSLHLULoop2ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the local line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 6 }

    --
    -- Remote line unit's 24 hour performance history
    --

    ctWanHDSLHRULoop1UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 7 }

    ctWanHDSLHRULoop1ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the remote line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 8 }

    ctWanHDSLHRULoop2UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 9 }

    ctWanHDSLHRULoop2ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the remote line unit during
             the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 10 }

    --
    -- Doubler 1's 15-minute performance history
    --

    ctWanHDSLDb1NetworkLoop1UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 11 }

    ctWanHDSLDb1NetworkLoop1ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the first doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 12 }

    ctWanHDSLDb1NetworkLoop2UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 13 }

    ctWanHDSLDb1NetworkLoop2ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the first doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 14 }

    ctWanHDSLDb1CustomerLoop1UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 15 }

    ctWanHDSLDb1CustomerLoop1ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the first doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 16 }

    ctWanHDSLDb1CustomerLoop2UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 17 }

    ctWanHDSLDb1CustomerLoop2ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the first doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 18 }

    --
    -- Doubler 2's 24-hour performance history
    --

    ctWanHDSLDb2NetworkLoop1UAS24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 19 }

    ctWanHDSLDb2NetworkLoop1ES24h  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the second doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 20 }

    ctWanHDSLDb2NetworkLoop2UAS24h OBJECT-TYPE
        SYNTAX     INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 21 }

    ctWanHDSLDb2NetworkLoop2ES24h OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the second doubler unit's
             network side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 22 }

    ctWanHDSLDb2CustomerLoop1UAS24h OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 23 }

    ctWanHDSLDb2CustomerLoop1ES24h OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 1 of the second doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 24 }

    ctWanHDSLDb2CustomerLoop2UAS24h OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 25 }

    ctWanHDSLDb2CustomerLoop2ES24h OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Errored seconds (ES) on LOOP 2 of the second doubler unit's
             customer side during the 24-hour period."
        ::= { ctWanHDSLPerformance24hEntry 26 }

    ----------------------------------------------------
    -- HDSL Statistics Table
    -- This group provides HDSL line statistics
    ----------------------------------------------------

    ctWanHDSLStatisticsTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLStatisticsEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "This table collects the statistics for the Signal noise ratio 
             (SNR), and the pulse attenuation of the HDSL line, including
             the local, remote units and the doublers in between." 
        ::= { ctWanHDSLExt 3 }

    ctWanHDSLStatisticsEntry  OBJECT-TYPE
        SYNTAX    CtWanHDSLStatisticsEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries of the HDSL statistics table "
        INDEX
            { ctWanHDSLStatisticsHLUConnIndex }
        ::= { ctWanHDSLStatisticsTable 1 }

    CtWanHDSLStatisticsEntry ::= SEQUENCE { 
        ctWanHDSLStatisticsHLUConnIndex
            INTEGER,
        ctWanHDSLSNRHLULoop1
            INTEGER,
        ctWanHDSLSNRLowHLULoop1
            INTEGER,
        ctWanHDSLSNRHighHLULoop1
            INTEGER,
        ctWanHDSLSNRHLULoop2
            INTEGER,
        ctWanHDSLSNRLowHLULoop2 
            INTEGER, 
        ctWanHDSLSNRHighHLULoop2 
            INTEGER, 
        ctWanHDSLPulseAttenuationHLULoop1
            INTEGER,
        ctWanHDSLPulseAttenuationHLULoop2
            INTEGER,
        ctWanHDSLBitStat1HLU
            INTEGER,
        ctWanHDSLSNRHRULoop1
            INTEGER,
        ctWanHDSLSNRLowHRULoop1 
            INTEGER, 
        ctWanHDSLSNRHighHRULoop1 
            INTEGER, 
        ctWanHDSLSNRHRULoop2
            INTEGER,
        ctWanHDSLSNRLowHRULoop2  
            INTEGER,  
        ctWanHDSLSNRHighHRULoop2  
            INTEGER,  
        ctWanHDSLPulseAttenuationHRULoop1
            INTEGER,
        ctWanHDSLPulseAttenuationHRULoop2
            INTEGER,
        ctWanHDSLDs1FrameHRU
            INTEGER,
        ctWanHDSLSNRDb1NetworkLoop1
            INTEGER,
        ctWanHDSLSNRLowDb1NetworkLoop1  
            INTEGER,  
        ctWanHDSLSNRHighDb1NetworkLoop1  
            INTEGER,  
        ctWanHDSLSNRDb1NetworkLoop2
            INTEGER,
        ctWanHDSLSNRLowDb1NetworkLoop2   
            INTEGER,   
        ctWanHDSLSNRHighDb1NetworkLoop2   
            INTEGER,   
        ctWanHDSLSNRDb1CustomerLoop1
            INTEGER,
        ctWanHDSLSNRLowDb1CustomerLoop1   
            INTEGER,   
        ctWanHDSLSNRHighDb1CustomerLoop1   
            INTEGER,   
        ctWanHDSLSNRDb1CustomerLoop2
            INTEGER,
        ctWanHDSLSNRLowDb1CustomerLoop2    
            INTEGER,   
        ctWanHDSLSNRHighDb1CustomerLoop2    
            INTEGER,    
        ctWanHDSLPulseAttenuationDb1NetworkLoop1
            INTEGER,
        ctWanHDSLPulseAttenuationDb1NetworkLoop2
            INTEGER,
        ctWanHDSLPulseAttenuationDb1CustomerLoop1
            INTEGER,
        ctWanHDSLPulseAttenuationDb1CustomerLoop2
            INTEGER,
        ctWanHDSLSNRDb2NetworkLoop1
            INTEGER,
        ctWanHDSLSNRLowDb2NetworkLoop1    
            INTEGER,    
        ctWanHDSLSNRHighDb2NetworkLoop1    
            INTEGER,    
        ctWanHDSLSNRDb2NetworkLoop2
            INTEGER,
        ctWanHDSLSNRLowDb2NetworkLoop2    
            INTEGER,    
        ctWanHDSLSNRHighDb2NetworkLoop2    
            INTEGER,    
        ctWanHDSLSNRDb2CustomerLoop1
            INTEGER,
        ctWanHDSLSNRLowDb2CustomerLoop1    
            INTEGER,   
        ctWanHDSLSNRHighDb2CustomerLoop1    
            INTEGER,    
        ctWanHDSLSNRDb2CustomerLoop2
            INTEGER,
        ctWanHDSLSNRLowDb2CustomerLoop2    
            INTEGER,    
        ctWanHDSLSNRHighDb2CustomerLoop2     
            INTEGER,     
        ctWanHDSLPulseAttenuationDb2NetworkLoop1
            INTEGER,
        ctWanHDSLPulseAttenuationDb2NetworkLoop2
            INTEGER,
        ctWanHDSLPulseAttenuationDb2CustomerLoop1
            INTEGER,
        ctWanHDSLPulseAttenuationDb2CustomerLoop2
            INTEGER
         }

    --
    -- Local line unit's statistics
    -- 

    ctWanHDSLStatisticsHLUConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify the HDSL connection occupied in the device,
             indexing from 1 to the maximum allowed connections in
             the device."
        ::= { ctWanHDSLStatisticsEntry 1 }

    ctWanHDSLSNRHLULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 2 }

    ctWanHDSLSNRLowHLULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Lowest SNR on LOOP 1 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 3 }

    ctWanHDSLSNRHighHLULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Highest SNR on LOOP 1 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 4 }
 
    ctWanHDSLSNRHLULoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 5 }

    ctWanHDSLSNRLowHLULoop2  OBJECT-TYPE 
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Lowest SNR on LOOP 2 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 6 } 
 
    ctWanHDSLSNRHighHLULoop2  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Highest SNR on LOOP 2 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 7 } 
 
    ctWanHDSLPulseAttenuationHLULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 1 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 8 }

    ctWanHDSLPulseAttenuationHLULoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 2 of the local line unit."
        ::= { ctWanHDSLStatisticsEntry 9 }

    ctWanHDSLBitStat1HLU  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "A byte value which contains product specific information:

             bit  0 - System in AIS on the local line unit.
                  1 - System in AIS on the remote line unit.
                  2 - Channels are reversed on the remote line unit.
                  3 - Channels are reversed on the doubler 1.
                  4 - Channels are reversed on the doubler 2.
                  5 - Power is fed to the next unit on the local line unit.
                  6 - Power is fed to the next unit on the remote line unit.
                  7 - Smartloop is active on remote line unit. (HiGain only)"
        ::= { ctWanHDSLStatisticsEntry 10 }

    --
    -- Remote line unit's statistics
    -- 

    ctWanHDSLSNRHRULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of the remote line unit." 
        ::= { ctWanHDSLStatisticsEntry 11 }

    ctWanHDSLSNRLowHRULoop1  OBJECT-TYPE  
        SYNTAX    INTEGER  
        ACCESS    read-only  
        STATUS    mandatory  
        DESCRIPTION  
            "Lowest SNR on LOOP 1 of the remote line unit."  
        ::= { ctWanHDSLStatisticsEntry 12 }  
 
    ctWanHDSLSNRHighHRULoop1  OBJECT-TYPE 
        SYNTAX    INTEGER  
        ACCESS    read-only  
        STATUS    mandatory  
        DESCRIPTION  
            "Highest SNR on LOOP 1 of the remote line unit."  
        ::= { ctWanHDSLStatisticsEntry 13 }  
 
    ctWanHDSLSNRHRULoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of the remote line unit."
        ::= { ctWanHDSLStatisticsEntry 14 }

    ctWanHDSLSNRLowHRULoop2  OBJECT-TYPE  
        SYNTAX    INTEGER  
        ACCESS    read-only  
        STATUS    mandatory  
        DESCRIPTION  
            "Lowest SNR on LOOP 2 of the remote line unit."  
        ::= { ctWanHDSLStatisticsEntry 15 }  

 
    ctWanHDSLSNRHighHRULoop2  OBJECT-TYPE 
        SYNTAX    INTEGER  
        ACCESS    read-only  
        STATUS    mandatory  
        DESCRIPTION  
            "Highest SNR on LOOP 2 of the remote line unit."  
        ::= { ctWanHDSLStatisticsEntry 16 }  
 
    ctWanHDSLPulseAttenuationHRULoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 1 of the remote line unit."
        ::= { ctWanHDSLStatisticsEntry 17 }

    ctWanHDSLPulseAttenuationHRULoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 2 of the remote line unit."
        ::= { ctWanHDSLStatisticsEntry 18 }

    ctWanHDSLDs1FrameHRU        OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Byte value shows DS1 frame and code information for the remote 
             line unit (HiGain only):
          
             bit 0:1 -
                 0 - frame format is SF.
                 1 - frame format is ESF.
                 2 - Frame format is unframed.
                 3 - no activity.
 
             bit 2:3 -
                 reserved.
 
             bit 4  -
                 0 - line code is AMI
                 1 - line code is B8ZS.
 
             bit 5:7 -
                 reserved."
  
        ::= { ctWanHDSLStatisticsEntry 19 }

    --
    -- Doubler 1's statistics
    -- 

    ctWanHDSLSNRDb1NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of doubler 1's network side"
        ::= { ctWanHDSLStatisticsEntry 20 }

    ctWanHDSLSNRLowDb1NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Lowest SNR on LOOP 1 of doubler 1's network side"
        ::= { ctWanHDSLStatisticsEntry 21 }

    ctWanHDSLSNRHighDb1NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Highest SNR on LOOP 1 of doubler 1's network side"
        ::= { ctWanHDSLStatisticsEntry 22 }

    ctWanHDSLSNRDb1NetworkLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of doubler 1's network side."
        ::= { ctWanHDSLStatisticsEntry 23 }

    ctWanHDSLSNRLowDb1NetworkLoop2  OBJECT-TYPE 
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory 
        DESCRIPTION 
            "Lowest SNR on LOOP 2 of doubler 1's network side."
        ::= { ctWanHDSLStatisticsEntry 24 } 
 
    ctWanHDSLSNRHighDb1NetworkLoop2  OBJECT-TYPE 
        SYNTAX    INTEGER
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Highest SNR on  LOOP 2 of doubler 1's network side." 
        ::= { ctWanHDSLStatisticsEntry 25 } 
 
    ctWanHDSLSNRDb1CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 26 }

    ctWanHDSLSNRLowDb1CustomerLoop1  OBJECT-TYPE  
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory  
        DESCRIPTION  
            "Lowest SNR on LOOP 1 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 27 }  
  
    ctWanHDSLSNRHighDb1CustomerLoop1  OBJECT-TYPE  
        SYNTAX    INTEGER 
        ACCESS    read-only  
        STATUS    mandatory  
        DESCRIPTION  
            "Highest SNR on LOOP 1 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 28 }  
 
    ctWanHDSLSNRDb1CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 29 }

    ctWanHDSLSNRLowDb1CustomerLoop2  OBJECT-TYPE   
        SYNTAX    INTEGER  
        ACCESS    read-only 
        STATUS    mandatory   
        DESCRIPTION   
            "Lowest SNR on LOOP 2 of doubler 1's customer side."   
        ::= { ctWanHDSLStatisticsEntry 30 }   
   
    ctWanHDSLSNRHighDb1CustomerLoop2  OBJECT-TYPE   
        SYNTAX    INTEGER  
        ACCESS    read-only   
        STATUS    mandatory   
        DESCRIPTION   
            "Highest SNR on LOOP 2 of doubler 1's customer side."   
        ::= { ctWanHDSLStatisticsEntry 31 }   
 
    ctWanHDSLPulseAttenuationDb1NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 1 of doubler 1's network side."
        ::= { ctWanHDSLStatisticsEntry 32 }

    ctWanHDSLPulseAttenuationDb1NetworkLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 2 of doubler 1's network side."
        ::= { ctWanHDSLStatisticsEntry 33 }

    ctWanHDSLPulseAttenuationDb1CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 1 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 34 }

    ctWanHDSLPulseAttenuationDb1CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 2 of doubler 1's customer side."
        ::= { ctWanHDSLStatisticsEntry 35 }

    --
    -- Doubler 2's Statistics
    -- 

    ctWanHDSLSNRDb2NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 36 }

    ctWanHDSLSNRLowDb2NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Lowest SNR on LOOP 1 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 37 }

    ctWanHDSLSNRHighDb2NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Highest SNR on LOOP 1 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 38 }

    ctWanHDSLSNRDb2NetworkLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 39 }

    ctWanHDSLSNRLowDb2NetworkLoop2  OBJECT-TYPE 
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory
        DESCRIPTION 
            "Lowest SNR on LOOP 2 of doubler 2's network side." 
        ::= { ctWanHDSLStatisticsEntry 40 } 
 
    ctWanHDSLSNRHighDb2NetworkLoop2  OBJECT-TYPE 
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Highest SNR on LOOP 2 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 41 } 
 
    ctWanHDSLSNRDb2CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 1 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 42 }

    ctWanHDSLSNRLowDb2CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Lowest SNR on LOOP 1 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 43 }

    ctWanHDSLSNRHighDb2CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Highest SNR on LOOP 1 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 44 }

    ctWanHDSLSNRDb2CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Current SNR on LOOP 2 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 45 }

    ctWanHDSLSNRLowDb2CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Lowest SNR on LOOP 2 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 46 } 
 
    ctWanHDSLSNRHighDb2CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only 
        STATUS    mandatory 
        DESCRIPTION 
            "Highest SNR on LOOP 2 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 47 } 
 
    ctWanHDSLPulseAttenuationDb2NetworkLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 1 of doubler 2's network side"
        ::= { ctWanHDSLStatisticsEntry 48 }

    ctWanHDSLPulseAttenuationDb2NetworkLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 2 of doubler 2's network side."
        ::= { ctWanHDSLStatisticsEntry 49 }

    ctWanHDSLPulseAttenuationDb2CustomerLoop1  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "pulse Attenuation on LOOP 1 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 50 }

    ctWanHDSLPulseAttenuationDb2CustomerLoop2  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Pulse Attenuation on LOOP 2 of doubler 2's customer side."
        ::= { ctWanHDSLStatisticsEntry 51 }

    ----------------------------------------------------
    -- HDSL Test Table
    ----------------------------------------------------

    ctWanHDSLTestTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLTestEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Test result for the HDSL line, the current test results only
             apply to the local line unit. "
        ::= { ctWanHDSLExt 4 }

    ctWanHDSLTestEntry  OBJECT-TYPE
        SYNTAX    CtWanHDSLTestEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries of the HDSL test results table."
        INDEX
            { ctWanHDSLTestHLUConnIndex }
        ::= { ctWanHDSLTestTable 1 }

    CtWanHDSLTestEntry ::= SEQUENCE { 
        ctWanHDSLTestHLUConnIndex
            INTEGER,
        ctWanHDSLTestMode
            INTEGER,
        ctWanHDSLHLUTestResult
            INTEGER,
        ctWanHDSLHRUTestResult
            INTEGER
     }

    ctWanHDSLTestHLUConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify the slot of the HDSL within the device that the user
             wants to conduct the line unit test. Slot number start from 
             1 to maximum slots available in the device."
        ::= { ctWanHDSLTestEntry 1 }

    ctWanHDSLTestMode  OBJECT-TYPE
        SYNTAX    INTEGER       
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
            "This object may only be successfully set on a master device.
             When this object is set, the local unit's test mode is
             defined by these values when set:

                1 - Normal operation
                3 - Self test mode
                4 - PROM check test
                5 - External RAM test
                6 - DS1 loop test
                7 - MUX-DMUX test
                9 - Analog loopback mode
               13 - Transceiver mode
             
             When getting this object, the value returned represents
             the last value this object had been set to."

        ::= { ctWanHDSLTestEntry 2 }

    ctWanHDSLHLUTestResult  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Test result for the local line unit (1 - test failed, 0 - success):
                 bit 0 - 2180 DS1 frame sync test (HiGain only)
                     1 - 2180 DS1 data test (HiGain only)
                     2 - LIU DS1 frame sync test (HiGain only)
                     3 - LIU DS1 data test (HiGain only)
                     4 - External DS1 frame sync test (HiGain only)
                     5 - External DS1 data test.
                     6 - Mux sync test on HDSL LOOP 1
                     7 - Mux sync test on HDSL LOOP 2
                     8 - Reserved.
                     9 - Mux frame error test on HDSL LOOP 1
                    10 - Mux frame error test on HDSL LOOP 2
                    11 - Mux CRC test on HDSL LOOP 1
                    12 - Mux CRC test on HDSL LOOP 2
                    13 - Mux DL test on HDSL LOOP 1
                    14 - Mux DL test on HDSL LOOP 2
                    15 - Analog loopback test.
                    16 - Digital loop test.
                    17 - HGF HDSL loop test (HiGain only)
                    18 - HGF write/readback test (HiGain only)
                    19 - HGF poll lock test (HiGain only).
                    20 - HGF activity monitor test (HiGain only).
                    21 - HGF zeroes TX and detect test (HiGain only).
                    22 - HGF ones TX and detect test (HiGain only).
                    23 - Transceiver poll test on HDSL LOOP 1
                    24 - Transceiver poll test on HDSL LOOP 2
                    25 - PROM check test.
                    26 - External RAM test.
                    27 - Non-Volatile RAM test.
             "
        ::= { ctWanHDSLTestEntry 3 }

    ctWanHDSLHRUTestResult  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Test results for the remote line unit,
             Bit definitions correspond to those defined for
             ctWanHDSLHLUTestResult. "
        ::= { ctWanHDSLTestEntry 4 }

    ----------------------------------------------------
    -- HDSL Alarms Table
    ----------------------------------------------------

    ctWanHDSLAlarmsTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLAlarmsEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "This table collects the existing alarms information for the HDSL
             line, including the local, remote line units and the doublers."
        ::= { ctWanHDSLExt 5 }

    ctWanHDSLAlarmsEntry    OBJECT-TYPE
        SYNTAX    CtWanHDSLAlarmsEntry
        ACCESS    not-accessible 
        STATUS    mandatory
        DESCRIPTION
            "Entries for the ctWanHDSL alarms information"
        INDEX
            { ctWanHDSLAlarmsHLUConnIndex }
        ::= { ctWanHDSLAlarmsTable 1 }

    CtWanHDSLAlarmsEntry ::= SEQUENCE { 
        ctWanHDSLAlarmsHLUConnIndex
            INTEGER,
        ctWanHDSLAlarmsBackplane
            INTEGER,
        ctWanHDSLAlarmsES
            INTEGER
     }

    ctWanHDSLAlarmsHLUConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify which HDSL connection within the device that
             the user wants to retrieve the alarm information."
        ::= { ctWanHDSLAlarmsEntry 1 }

    ctWanHDSLAlarmsBackplane  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Specific information that's related to the HDSL alarms, each bit
             in the two bytes value has the following meaning if set: 

             Bit 0 : Local Loss of Signal on DS1 line (HiGain only).
                 1 : Remote Loss of Signal on DS1 list (HiGain only).
                 2 - 7 : reserved.
                 8 : Loss of Sync word on LOOP 1 of the local line unit.
                 9 : Loss of Sync word on LOOP 2 of the local line unit. 
                10  : Loss of Sync word on LOOP 1 of the first doubler.
                11 : Loss of sync word on LOOP 2 of the first doubler.
                12 : Loss of Sync word on LOOP 1 of the second doubler.
                13 : Loss of sync word on LOOP 2 of the second doubler."
        ::= { ctWanHDSLAlarmsEntry 2 }
 
    ctWanHDSLAlarmsES    OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "A two bytes value for the Errored Second indication of the HDSL 
             line unit, including local, remote line units and the doublers.
             each bit in the two bytes value has the following meaning if set: 

             Bit 0 : Errored Second on LOOP 1 of local line unit.
                 1 : Errored Second on LOOP 2 of local line unit. 
                 2 : Errored Second on LOOP 1 of remote line unit.
                 3 : Errored Second on LOOP 2 of remote line unit.  
                 4 : Errored Second on LOOP 1 of local line unit's network side.
                 5 : Errored Second on LOOP 2 of local line unit's network side.
                 6 : Errored Second on LOOP 1 of local line unit's customer side.
                 7 : Errored Second on LOOP 2 of local line unit's customer side."
        ::= { ctWanHDSLAlarmsEntry 3 }

    ----------------------------------------------------
    -- HDSL Alarm History Table
    ----------------------------------------------------

    ctWanHDSLAlarmHistoryTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLAlarmHistoryEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "HDSL Alarm History table. This table provides the accumulated 
             counts of Errored Seconds (ES) and Loss of Sync words (LOS)
             as well as the time stamp of the above events occurred for both
             of the HDSL loops.

             The time stamps show the date in MMDDYYYYHHMM format."
        ::= { ctWanHDSLExt 6 }
 
    ctWanHDSLAlarmHistoryEntry  OBJECT-TYPE
        SYNTAX    CtWanHDSLAlarmHistoryEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries in the Alarm History table"
        INDEX
            { ctWanHDSLAlarmHistoryConnIndex }
        ::= { ctWanHDSLAlarmHistoryTable 1  }
 
    CtWanHDSLAlarmHistoryEntry ::= SEQUENCE { 
        ctWanHDSLAlarmHistoryConnIndex
            INTEGER,
        ctWanHDSLAlHistLLOSFirst
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLLOSLast
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLLOSCurrent
            INTEGER,
        ctWanHDSLAlHistLLOSCount
            INTEGER,
        ctWanHDSLAlHistRLOSFirst
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistRLOSLast
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistRLOSCurrent
            INTEGER,
        ctWanHDSLAlHistRLOSCount
            INTEGER,
        ctWanHDSLAlHistLOSW1First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLOSW1Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLOSW1Current
            INTEGER,
        ctWanHDSLAlHistLOSW1Count
            INTEGER,
        ctWanHDSLAlHistLOSW2First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLOSW2Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistLOSW2Current
            INTEGER,
        ctWanHDSLAlHistLOSW2Count
            INTEGER,
        ctWanHDSLAlHistES1First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistES1Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistES1Current
            INTEGER,
        ctWanHDSLAlHistES1Count
            INTEGER,
        ctWanHDSLAlHistES2First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistES2Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistES2Current
            INTEGER,
        ctWanHDSLAlHistES2Count
            INTEGER,
        ctWanHDSLAlHistMargin1First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistMargin1Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistMargin1Current
            INTEGER,
        ctWanHDSLAlHistMargin1Count
            INTEGER,
        ctWanHDSLAlHistMargin2First
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistMargin2Last
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistMargin2Current
            INTEGER,
        ctWanHDSLAlHistMargin2Count
            INTEGER,
        ctWanHDSLAlHistCleared
            DisplayString(SIZE(12)),
        ctWanHDSLAlHistClearit
            INTEGER
     }

    ctWanHDSLAlarmHistoryConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Defines which HDSL connection's alarm history within the
             device."
        ::= { ctWanHDSLAlarmHistoryEntry 1 }
 
    ctWanHDSLAlHistLLOSFirst  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the DS1 Loss Of Signal (LOS) 
             occurred on the local side of the HDSL."
        ::= { ctWanHDSLAlarmHistoryEntry 2  }

    ctWanHDSLAlHistLLOSLast  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the DS1 Loss Of Signal (LOS) 
             occurred on the local side of the HDSL."
         ::= { ctWanHDSLAlarmHistoryEntry 3  }

    ctWanHDSLAlHistLLOSCurrent  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the DS1 Loss Of Signal (LOS) still occurred on the 
             local side of the HDSL."
        ::= { ctWanHDSLAlarmHistoryEntry 4  }

    ctWanHDSLAlHistLLOSCount  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the DS1 Loss Of Signal (LOS) occurred since 
             we last cleared the alarm history on the local side of the HDSL. 
             (HiGain only)"
        ::= { ctWanHDSLAlarmHistoryEntry 5  }

    ctWanHDSLAlHistRLOSFirst  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time  the DS1 Loss Of Signal (LOS) 
             occurred on the remote side of the HDSL. (HiGain only)"
        ::= { ctWanHDSLAlarmHistoryEntry 6  }
 
    ctWanHDSLAlHistRLOSLast  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred
             on the remote side of the HDSL. (HiGain only)"
        ::= { ctWanHDSLAlarmHistoryEntry 7  }
 
    ctWanHDSLAlHistRLOSCurrent  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the DS1 Loss Of Signal (LOS) still occurred on the remote 
             site of the HDSL. (HiGain only)"
        ::= { ctWanHDSLAlarmHistoryEntry 8  }
 
    ctWanHDSLAlHistRLOSCount  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the DS1 Loss Of Signal (LOS) occurred since we 
             last cleared the alarm history on the remote site of the HDSL. 
             (HiGain only)"
        ::= { ctWanHDSLAlarmHistoryEntry 9  }
 
    ctWanHDSLAlHistLOSW1First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
             on the LOOP 1 of the HDSL link." 
        ::= { ctWanHDSLAlarmHistoryEntry 10  }
 
    ctWanHDSLAlHistLOSW1Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
             on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 11  }
 
    ctWanHDSLAlHistLOSW1Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1 
             of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 12  }
 
    ctWanHDSLAlHistLOSW1Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the Loss Of Sync Word (LOSW) occurred since we 
             last cleared the history on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 13  }

    ctWanHDSLAlHistLOSW2First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
             on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 14  }
 
    ctWanHDSLAlHistLOSW2Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
             on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 15  }
 
    ctWanHDSLAlHistLOSW2Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2 
             of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 16  }
 
    ctWanHDSLAlHistLOSW2Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the Loss Of Sync Word (LOSW) occurred since we 
             last cleared the history on the LOOP 2 of the HDSL link. "
        ::= { ctWanHDSLAlarmHistoryEntry 17  }
 
    ctWanHDSLAlHistES1First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the Errored Seconds (ES) occurred
             on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 18  }
 
    ctWanHDSLAlHistES1Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the Errored Seconds (ES) occurred
             on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 19  }
 
    ctWanHDSLAlHistES1Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the Errored Seconds (ES) still occurred on the LOOP 1 of 
             the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 20  }
 
    ctWanHDSLAlHistES1Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the Errored Seconds (ES) occurred since we last
             cleared the alarm history on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 21  }

    ctWanHDSLAlHistES2First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the Errored Seconds (ES) occurred
             on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 22  }
 
    ctWanHDSLAlHistES2Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the Errored Seconds (ES) occurred
             on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 23  }
 
    ctWanHDSLAlHistES2Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the Errored Seconds (ES) still occurred on the LOOP 2 of 
             the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 24  }
 
    ctWanHDSLAlHistES2Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the Errored Seconds (ES) occurred since we last
             cleared the history on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 25  }

    ctWanHDSLAlHistMargin1First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the alarms exceeded the 
             Margin Threshold on LOOP 1 of the HDSL link." 
        ::= { ctWanHDSLAlarmHistoryEntry 26  }
 
    ctWanHDSLAlHistMargin1Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time the alarms exceeded the Margin
             Threshold  on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 27  }
 
    ctWanHDSLAlHistMargin1Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the alarms still exceeded the Margin Threshold
             on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 28  }
 
    ctWanHDSLAlHistMargin1Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the alarm exceeded the Margin Threshold since 
             we last cleared the alarm history on the LOOP 1 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 29  }

    ctWanHDSLAlHistMargin2First  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the first time the alarms exceeded the Margin
             Threshold on LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 30  }
 
    ctWanHDSLAlHistMargin2Last  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the last time  the alarms exceeded the Margin 
             Threshold  on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 31  }
 
    ctWanHDSLAlHistMargin2Current  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Set if the alarms still exceeded the Margin Threshold
             on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 32  }
 
    ctWanHDSLAlHistMargin2Count  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Number of times the alarm exceeded the Margin Threshold since
             we last cleared the alarm history on the LOOP 2 of the HDSL link."
        ::= { ctWanHDSLAlarmHistoryEntry 33  }

    ctWanHDSLAlHistCleared  OBJECT-TYPE
        SYNTAX    DisplayString(SIZE(12)) 
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Time stamp of the time user requested to clear the alarm history."
        ::= { ctWanHDSLAlarmHistoryEntry 34  }

    ctWanHDSLAlHistClearit  OBJECT-TYPE
        SYNTAX    INTEGER 
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
            "set to a 1 to  clear the alarm history.
             A read of this value always returns a 1.

             NOTE: the setting of this object also causes the SNR low
             value, SNR high value, and the performance history to be
             reset."

        ::= { ctWanHDSLAlarmHistoryEntry 35  }

    ----------------------------------------------------
    -- HDSL Loopbacks Table
    ----------------------------------------------------

    ctWanHDSLLoopbacksTable     OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtWanHDSLLoopbacksEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
          "HDSL Loopback table. This table provides the certain loopback 
            settings for the HDSL link."
        ::= { ctWanHDSLExt 7 }

    ctWanHDSLLoopbacksEntry   OBJECT-TYPE
        SYNTAX    CtWanHDSLLoopbacksEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
            "Entries in the HDSL Loopback table."
        INDEX
            { ctWanHDSLLoopbacksHLUConnIndex }
        ::= { ctWanHDSLLoopbacksTable 1 }

    CtWanHDSLLoopbacksEntry ::= SEQUENCE { 
        ctWanHDSLLoopbacksHLUConnIndex
            INTEGER,
        ctWanHDSLLoopbacksAdminType
            INTEGER,
        ctWanHDSLLoopbacksOperType
            INTEGER
     }

    ctWanHDSLLoopbacksHLUConnIndex  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "Identify the HDSL connection within the device"
        ::= { ctWanHDSLLoopbacksEntry 1 }

    ctWanHDSLLoopbacksAdminType  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-write 
        STATUS    mandatory
        DESCRIPTION
            "This is the requested loopback type for the HDSL.

             loopbacks setting:
                 1 : Smartjack - loopback to network at remote line unit. 
                 2 : Loopback to network at local line unit. 
                 3 : Loopback to network at remote line unit. 
                 4 : Loopback to customer at local line unit. 
                 5 : Loopback to customer at remote line unit. 
                 6 : Loopback to customer at first doubler.
                 7 : Loopback to customer at second doubler. 
                 8 : Loopback to network at first doubler.
                 9 : Loopback to network at second doubler.
                 10: No loopback (turn loopback off). "
        ::= { ctWanHDSLLoopbacksEntry 2 }

    ctWanHDSLLoopbacksOperType  OBJECT-TYPE
        SYNTAX    INTEGER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
            "This is the operational loopback type for the HDSL.

             loopbacks setting:
                 1 : Smartjack - loopback to network at remote line unit. 
                 2 : Loopback to network at local line unit. 
                 3 : Loopback to network at remote line unit. 
                 4 : Loopback to customer at local line unit. 
                 5 : Loopback to customer at remote line unit. 
                 6 : Loopback to customer at first doubler.
                 7 : Loopback to customer at second doubler. 
                 8 : Loopback to network at first doubler.
                 9 : Loopback to network at second doubler.
                 10: No loopback (turn loopback off). "
        ::= { ctWanHDSLLoopbacksEntry 3 }