CTRON-WAN-MIB device MIB details by Enterasys Networks Inc
CTRON-WAN-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTRON-WAN-MIB.
Vendor: | Enterasys Networks Inc |
---|---|
Mib: | CTRON-WAN-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
CTRON-WAN-MIB DEFINITIONS ::= BEGIN -- CTRON-WAN-MIB The Cabletron Wide area MIB. -- Revision: 01.08.06 -- Part Number: 2170989 -- Date: May 20, 1998 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for part -- of the naming tree below: -- -- cabletron { enterprises 52 } -- -- This module will be extended, as additional sub-sections -- of this naming tree are defined. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright August 95 Cabletron Systems IMPORTS OBJECT-TYPE FROM RFC-1212 ctWan FROM CTRON-MIB-NAMES DisplayString FROM RFC1213-MIB IpAddress, Counter FROM RFC1155-SMI; -- variables Index ::= INTEGER DLCI ::= INTEGER -- DisplayString ::= OCTET STRING --==================================================================== -- Groups ctWanConnection OBJECT IDENTIFIER ::= { ctWan 1 } ctWanDs1 OBJECT IDENTIFIER ::= { ctWan 2 } ctWanRs232 OBJECT IDENTIFIER ::= { ctWan 3 } ctFrDcp OBJECT IDENTIFIER ::= { ctWan 4 } ctDDS OBJECT IDENTIFIER ::= { ctWan 5 } ctDs1Alarms OBJECT IDENTIFIER ::= { ctWan 6 } ctIPPQFilters OBJECT IDENTIFIER ::= { ctWan 7 } ctWanHDSLExt OBJECT IDENTIFIER ::= { ctWan 8 } -- ctWanConnection Group -- This group is mandatory for all platforms that have one or more -- Wan Connections wanNumConnections OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This objects describes the number of wan connections on the platform. A wan connection may have one or two physical ports of which only one can be active at any time." ::= { ctWanConnection 1 } wanConnTable OBJECT-TYPE SYNTAX SEQUENCE OF WanConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of wan connection entries. The number of wan connection entries is given by the value of wanNumConnections." ::= { ctWanConnection 2 } wanConnEntry OBJECT-TYPE SYNTAX WanConnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A wan connection entry containing objects relating to the particular wan connection." INDEX { wanConnIndex } ::= { wanConnTable 1 } WanConnEntry ::= SEQUENCE { wanConnIndex INTEGER, wanConnNumPhysPorts INTEGER, wanConnDefaultPhysPort INTEGER, wanConnActivePhysPort INTEGER } wanConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each wan connection. Its value ranges between 1 and the value wanNumConnections." ::= { wanConnEntry 1 } wanConnNumPhysPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of physical ports that exist on this wan connection." ::= { wanConnEntry 2 } wanConnDefaultPhysPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The default physical port for this connection. This indicates the physical port that should be used on this wan connection. If redundancy is not enabled, this physical port will always be used. If redundancy is enabled, the physical port given here will be considered the primary physical port. The value of this object must be set to the index of a valid physical port (wanPhysPortIndex) for this wan connection." ::= { wanConnEntry 3 } wanConnActivePhysPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The physical port that is currently active for this wan connection. The value of this object indicates the wanPhysPortIndex for the active port." ::= { wanConnEntry 4 } wanPhysPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WanPhysPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the descriptions of the physical ports of this platform. The number of entries is given by the value of wanConnNumPhysPort for each Wan Connection." ::= { ctWanConnection 3 } wanPhysPortEntry OBJECT-TYPE SYNTAX WanPhysPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A physical port entry. It contains objects relating to a given physical port" INDEX { wanPhysPortConnectionIndex, wanPhysPortIndex } ::= { wanPhysPortTable 1 } WanPhysPortEntry ::= SEQUENCE { wanPhysPortConnectionIndex INTEGER, wanPhysPortIndex INTEGER, wanPhysPortType INTEGER, wanPhysPortSpecificMib OBJECT IDENTIFIER } wanPhysPortConnectionIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A value indicating the wan connection this physical port is located on." ::= { wanPhysPortEntry 1 } wanPhysPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each physical port on a wan connection. Its value ranges between 1 and the value wanConnNumPhysPorts." ::= { wanPhysPortEntry 2 } wanPhysPortType OBJECT-TYPE SYNTAX INTEGER { none(1), t1(2), e1(3), synchronous(4), dds(5), di(6), hdsl(7), bri(8), ds30(9), t1DDS(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of physical port that this entry describes. None indicates that the physical port has no connector." ::= { wanPhysPortEntry 3 } wanPhysPortSpecificMib OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies an instance of the index object in the first group of objects in the MIB specific to the physical port." ::= { wanPhysPortEntry 4 } wanInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF WanInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The interface table for a physical port on a wan connection. It is a list of items that are pertinent to the interfaces that are part of this physical port. The number of entries is dependent on the wanPhysPortType for the interface. If the wanPhysPortType is none, there will be no entries in the table for the port. If the wanPhysPortType is t1, there will be 24 entries in this table for the port. If the wanPhysPortType is e1, there will be 30 entries in this table for the port. If the wanPhysPortType is synchronous, there will be one entry in this table for the port. " ::= { ctWanConnection 4 } wanInterfaceEntry OBJECT-TYPE SYNTAX WanInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A wan connection physical port interface entry. It contains objects relating to an interface that is defined for this physical port and this wan connection." INDEX { wanInterfaceConnectionIndex, wanInterfacePhysPortIndex, wanInterfaceEntryIndex } ::= { wanInterfaceTable 1} WanInterfaceEntry ::= SEQUENCE { wanInterfaceConnectionIndex INTEGER, wanInterfacePhysPortIndex INTEGER, wanInterfaceEntryIndex INTEGER, wanInterfaceEntryIfIndex INTEGER, wanInterfaceEntryProtocol INTEGER, wanInterfaceEntryCompression INTEGER, wanInterfaceEntryMTU INTEGER, wanInterfaceEntryLineCoding INTEGER, wanInterfaceEntryCrcLength INTEGER, wanInterfaceEntryLexProtocolEnable INTEGER, wanInterfaceEntryLexProtocolStatus INTEGER, wanInterfaceEntryCompRatio OCTET STRING, wanInterfaceEntryCompStatus INTEGER, wanInterfaceEntryBackUpIfEnable INTEGER } wanInterfaceConnectionIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value is the wan connection that this interface exists on." ::= { wanInterfaceEntry 1} wanInterfacePhysPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value is the physical port of the wan connection that this interface exists on." ::= { wanInterfaceEntry 2} wanInterfaceEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each interface of this physical port. It is a value between 1 and the number of interfaces that exist for the current port. The number of interfaces for each type of port is: 24 for a port type (wanPhysPortType) of 't1', 30 for a port type of 'e1', and 1 for a port type of 'synchronous'. There will be no entries if the port type is 'none'." ::= { wanInterfaceEntry 3} wanInterfaceEntryIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex of the interface. This is the index of this entry in the ifTable." REFERENCE "rfc-1213" ::= { wanInterfaceEntry 4} wanInterfaceEntryProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The protocol that should be run on this interface. Values are equivalent to those defined for ifType in Mib-II. Accepted values are product dependent." REFERENCE "rfc-1213, product literature" ::= { wanInterfaceEntry 5} wanInterfaceEntryCompression OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether data compression should take place on this interface." ::= { wanInterfaceEntry 6} wanInterfaceEntryMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The MTU to be negotiated for this interface. This will not be updated with the actual MTU, which can be found in the ifTable." ::= { wanInterfaceEntry 7} wanInterfaceEntryLineCoding OBJECT-TYPE SYNTAX INTEGER { none (1), jBZS (2), invHDLC (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object describes the variety of Zero Code suppression on this interface. For an interface on a Ds1 Port, the valid values depend on the value of the Ds1ConfigLineCode object. If that object is set to ds1xB8ZS, then this object can be set to none, JBZS, or InvHDLC. If the value of Ds1ConfigLineCode is set to ds1xAMI, then this object can only be set to JBZS, or InvHDLC. For an interface on a Synchronous Port, the valid values are none or InvHDLC. JBZS refers to Jammed Bit Zero suppression, which forces a 1 bit every 8 bit periods. InvHDLC refers to inverting the HDLC data for the interface. None refers to a mode in which some other means, such as with the Ds1ConfigLineCode object set to dsx1B8ZS, is used to insure pulse density requirements." REFERENCE "rfc-1406" ::= { wanInterfaceEntry 8} wanInterfaceEntryCrcLength OBJECT-TYPE SYNTAX INTEGER { sixteen-bits(1), thirty-two-bits(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Length of the CRC for this interface. Not all platforms will allow all options." ::= { wanInterfaceEntry 9} wanInterfaceEntryLexProtocolEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS deprecated DESCRIPTION "This switch acts in concert with the wanInterfaceEntryProtocol object. To activate LEX, this object should first be set to enable (1), then set the wanInterfaceEntryProtocol to PPP. The enable will have no effect if PPP is not selected. If the wanInterfaceEntryProtocol is selected first, the default NCP of BNCP will be selected. To De-select LEX, you must set this object to disable (2), and wanInterfaceEntryProtocol to NONE or reset the device. Just selecting disable (2) will not tear down the connection." ::= { wanInterfaceEntry 10} wanInterfaceEntryLexProtocolStatus OBJECT-TYPE SYNTAX INTEGER { bound (1), unbound (2) } ACCESS read-only STATUS deprecated DESCRIPTION "This object reflects the current state of the link. The device is said to be bound to the router when the physical link is OK, the LEX negotiation is successful, and the router has been configured correctly to communicate with this particular LAN Extender." ::= { wanInterfaceEntry 11} wanInterfaceEntryCompRatio OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "The ratio of uncompressed to compressed transmitted data. If the data compression status is off, 1:1 will be displayed" ::= { wanInterfaceEntry 12} wanInterfaceEntryCompStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-only STATUS mandatory DESCRIPTION "On indicates that the compression has been successfully negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been terminated by either peer." ::= { wanInterfaceEntry 13} wanInterfaceEntryBackUpIfEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to select the Call-backup option. A value of 1 is used to enable the option and a value of 2 to disable it." ::= { wanInterfaceEntry 14} -- Wan Ds1 Group -- This group is required for any platforms that have a t1 or e1 physical port. -- wanDs1ExtensionsTable OBJECT-TYPE SYNTAX SEQUENCE OF WanDs1ExtensionsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is an extension to the standard ds1 configuration table. It is a list of items that are pertinent to ds1 ports on a platform. There is one entry per ds1 physical port on the platform" ::= { ctWanDs1 1 } wanDs1ExtensionsEntry OBJECT-TYPE SYNTAX WanDs1ExtensionsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A ds1 extensions entry containing objects relating to the particular ds1 physical port" INDEX { wanDs1ExtensionsEntryIndex } ::= { wanDs1ExtensionsTable 1 } WanDs1ExtensionsEntry ::= SEQUENCE { wanDs1ExtensionsEntryIndex INTEGER, wanDs1ExtensionsNumInterfaces INTEGER, wanDs1ExtensionsToggleFracTable INTEGER, wanDs1ExtensionsLineBuildOut INTEGER, wanDs1ExtensionsCFADuration INTEGER, wanDs1ExtensionsDIEnable INTEGER, wanDs1ExtensionsTotalValidIntervals Counter, wanDs1ExtensionsBertTestMode INTEGER, wanDs1ExtensionsBertRun INTEGER, wanDs1ExtensionsBertCurrentResults INTEGER, wanDs1ExtensionsBertCumulativeResults INTEGER, wanDs1ExtensionsBertPeakResults INTEGER, wanDs1ExtensionsBertAverageResult INTEGER, wanDs1ExtensionsBertTestPattern INTEGER, wanDs1ExtensionsBertSamplePeriod INTEGER, wanDs1ExtensionsBertNumPeriods Counter, wanDs1ExtensionsBertTestTraps INTEGER, wanDs1ExtensionsBertDataStatus INTEGER } wanDs1ExtensionsEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each ds1 physical port on the platform." ::= { wanDs1ExtensionsEntry 1 } wanDs1ExtensionsNumInterfaces OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of interfaces on this physical port. This number indicates the number of entries this physical port uses in the ifTable." REFERENCE "rfc-1213" ::= { wanDs1ExtensionsEntry 2 } wanDs1ExtensionsToggleFracTable OBJECT-TYPE SYNTAX INTEGER { update-table(1), display-new(2), display-old(3), restore-old(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to 1 will cause the Ds1 Fractional Table to be updated with the new values, as entered. Setting this object to 2, will cause the Ds1 Fractional Table to view as the table being entered. Setting this object to 3, will cause the Ds1 Fractional Table to be the table that is currently in use, regardless of any changes being entered. Setting this object to 4, will cause any changes that have been made to the Ds1 Fractional Table since the last update-table to be deleted. For physical ports of type synchronous, this object will have no affect, and will always return a 1." REFERENCE "rfc-1406" ::= { wanDs1ExtensionsEntry 3 } wanDs1ExtensionsLineBuildOut OBJECT-TYPE SYNTAX INTEGER { unknown(1), zero(2), minus-7point5(3), minus-15(4), a133to266feet(5), a266to399feet(6), a399to533feet(7), a533to655feet(8) } ACCESS read-write STATUS mandatory DESCRIPTION "The line build out setting for this ds1 physical port. Unknown indicates that the setting is neither readable or writable." ::= { wanDs1ExtensionsEntry 4 } wanDs1ExtensionsCFADuration OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS read-write STATUS mandatory DESCRIPTION "The length of time (in seconds), that the ds1 port will remain in the Carrier Failure Alarm state after the alarm condition has cleared." ::= { wanDs1ExtensionsEntry 5 } wanDs1ExtensionsDIEnable OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2), diDataEnabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables Drop and Insert functionality on a D/I WPIM. If enabled, all zero assigned timeslots will designate D/I interface channels, if disabled all zero channels will designate dummy channels as on a T1 or E1. If this object is set to diDataEnabled the zero channels will designate D/I interface channels and data to and from the device will be transmitted or received on the D/I port instead of the N/I port." ::= { wanDs1ExtensionsEntry 6 } wanDs1ExtensionsTotalValidIntervals OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous intervals for which valid data was collected for the DS1 mib, which is currently RFC1406. This counter is similar to RFC1406 dsx1ValidIntervals except that the count represents the total number of complete 15 minute intervals since the ds1 interface has been online, and does not stop at the 24 hour period." ::= { wanDs1ExtensionsEntry 7 } wanDs1ExtensionsBertTestMode OBJECT-TYPE SYNTAX INTEGER{ none(1), internal(2), manual(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to request that a type of process be in control of the testing function. This is used to differentiate between automated test procedures and those manually controlled by a user. When read, this object reflects which type of process is actually in control of the testing function. The implementation is free to prioritize or deny requests in a proprietary manner." ::= { wanDs1ExtensionsEntry 8 } wanDs1ExtensionsBertRun OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the sending of test data over this physical port. The data is a pattern described by wanDs1ExtensionsBertTestPattern." ::= { wanDs1ExtensionsEntry 9 } wanDs1ExtensionsBertCurrentResults OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the results of the testing for the last completed sampling period. A non-negative number is the error rate in bits per million bits." ::= { wanDs1ExtensionsEntry 10 } wanDs1ExtensionsBertCumulativeResults OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of errors since the testing was enabled. It is not a rate." ::= { wanDs1ExtensionsEntry 11 } wanDs1ExtensionsBertPeakResults OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the highest value of wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits." ::= { wanDs1ExtensionsEntry 12 } wanDs1ExtensionsBertAverageResult OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the average value of wanDs1ExtensionsBertCurrentResults since the testing was enabled. A non-negative number is the error rate in bits per million bits." ::= { wanDs1ExtensionsEntry 13 } wanDs1ExtensionsBertTestPattern OBJECT-TYPE SYNTAX INTEGER { patternOther(1), pattern1s(2), pattern63(3), pattern511(4), pattern2047(5), pattern3in24(6), patternQRSS(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to specify the pattern of the test data." ::= { wanDs1ExtensionsEntry 14 } wanDs1ExtensionsBertSamplePeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object is the duration of time in seconds at which the current test results will be periodically written to wanDs1ExtensionsBertCurrentResults. The range is 1 to 3600, with a default value of 10." ::= { wanDs1ExtensionsEntry 15 } wanDs1ExtensionsBertNumPeriods OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " The number of sampling periods that have elapsed during the current test run." ::= { wanDs1ExtensionsEntry 16 } wanDs1ExtensionsBertTestTraps OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable or disable the sending of a trap at the conclusion of the measurement period. The trap will contain the information described by ctDs1BertCurrentResults. The default value is disabled." ::= { wanDs1ExtensionsEntry 17 } wanDs1ExtensionsBertDataStatus OBJECT-TYPE SYNTAX INTEGER { idle(1), waitingForLink(2), waitingForLoopback(3), running(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the operating status of the transmission of test data packets." ::= { wanDs1ExtensionsEntry 18 } -- Wan Rs232 Group -- This group is only required if any physical port on the system can be -- classified as rs232-like -- wanRs232ExtensionsTable OBJECT-TYPE SYNTAX SEQUENCE OF WanRs232ExtensionsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is an extension to the standard rs232-like mib. It is a list of items that are pertinent to rs232-like ports on a platform. There is one entry per synchronous physical port on the platform." REFERENCE "rfc-1317" ::= { ctWanRs232 1 } wanRs232ExtensionsEntry OBJECT-TYPE SYNTAX WanRs232ExtensionsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A rs232-like extensions entry containing objects relating to the particular rs232-like physical port." INDEX { wanRs232ExtensionsEntryIndex } ::= { wanRs232ExtensionsTable 1 } WanRs232ExtensionsEntry ::= SEQUENCE { wanRs232ExtensionsEntryIndex INTEGER, wanRs232ExtensionsCTSEnable INTEGER, wanRs232ExtensionsDSREnable INTEGER } wanRs232ExtensionsEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each rs232-like physical port on the platform." ::= { wanRs232ExtensionsEntry 1 } wanRs232ExtensionsCTSEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates whether the platform should generate CTS. When disabled the platform will not generate CTS, when enabled, the platform will generate CTS. The actual state of the CTS line is available in the rs-232 like mib." REFERENCE "rfc-1317" DEFVAL { disable } ::= { wanRs232ExtensionsEntry 2 } wanRs232ExtensionsDSREnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates whether the platform should generate DSR. When disabled the platform will not generate DSR, when enabled, the platform will generate DSR. The actual state of the DSR line is available in the rs-232 like mib." REFERENCE "rfc-1317 " DEFVAL { disable } ::= { wanRs232ExtensionsEntry 3 } -- ctFrDcp Group -- This group is mandatory to support Data Compression Protocol -- (DCP following FRF.9) for per virtual circuit basis frDcpCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF FrDcpCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing data compression information about specific Data Link Connection Identifiers and corresponding virtual circuit. This information is used to support the frCircuitTable following RFC-1315." ::= { ctFrDcp 1 } frDcpCircuitEntry OBJECT-TYPE SYNTAX FrDcpCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The data compression information regarding a single Data Link Connection Identifier." INDEX { frDcpCircuitIfIndex, frDcpCircuitDlci } ::= { frDcpCircuitTable 1 } FrDcpCircuitEntry ::= SEQUENCE { frDcpCircuitIfIndex Index, frDcpCircuitDlci DLCI, frDcpCircuitEnable INTEGER, frDcpCircuitStatus INTEGER, frDcpCircuitRatio OCTET STRING } frDcpCircuitIfIndex OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value of ifEntry that this DCP virtual circuit object is layered onto." ::= { frDcpCircuitEntry 1 } frDcpCircuitDlci OBJECT-TYPE SYNTAX DLCI ACCESS read-only STATUS mandatory DESCRIPTION "The Data Link Connection Identifier for this DCP virtual circuit object." REFERENCE "Draft American National Standard T1.618-1991, Section 3.3.6" ::= { frDcpCircuitEntry 2 } frDcpCircuitEnable OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) -- default } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether data compression should take place on this particular end side virtual circuit." ::= { frDcpCircuitEntry 3 } frDcpCircuitStatus OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } ACCESS read-only STATUS mandatory DESCRIPTION "On indicates that the compression has been successfully negotiated and is operating. Off indicates that the compression negotiation has failed and compression is not operating at this time, or compression has been terminated by either peer." ::= { frDcpCircuitEntry 4 } frDcpCircuitRatio OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "The ratio of uncompressed to compressed transmitted data. If the data compression status is off, 1:1 will be displayed" ::= { frDcpCircuitEntry 5 } -- -- Wan DDS Group -- This group is required for any platforms that have a dds physical port. -- ddsConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DdsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DDS Configuration Table" ::= { ctDDS 1} ddsConfigEntry OBJECT-TYPE SYNTAX DdsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the DDS Configuration Table" INDEX { ddsLineIndex } ::= { ddsConfigTable 1 } DdsConfigEntry ::= SEQUENCE { ddsLineIndex INTEGER, ddsIfIndex INTEGER, ddsLineMode INTEGER, ddsLineCoding INTEGER, ddsLoopbackConfig INTEGER, ddsLineStatus INTEGER, ddsTxClockSource INTEGER, ddsPortInSpeed INTEGER, ddsPortOutSpeed INTEGER } ddsLineIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each dds physical port on the platform" ::= { ddsConfigEntry 1 } ddsIfIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "Index associated with this dds physical port" ::= { ddsConfigEntry 2 } ddsLineMode OBJECT-TYPE SYNTAX INTEGER { ddsPri (1), ddsCc (2) } ACCESS read-write STATUS mandatory DESCRIPTION "DDS-PRI is full duplex 56k link, No framing in loop data so loop speed is also 56k. Data stream: --d1 d2 d3 d4 d5 d6 d7-- DDS-CC is full duplex 64k link. Does not require framing bit but uses a same format as SC, ninth bit position is lumped with primary channel and not used for control. Loop speed is 72k, Primary channel rate is 64k. --d1 d2 d3 d4 d5 d6 d7 F d8--" ::= { ddsConfigEntry 3 } ddsLineCoding OBJECT-TYPE SYNTAX INTEGER { ddsNone (1), ddsJBZS (2), otherLineCode (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object describes the variety of Zero Code suppression on this interface. JBZS refers to Jammed Bit Zero suppression, which forces a 1 bit every 8 bit periods. None refers to a mode in which some other means is used to insure pulse density requirements." ::= { ddsConfigEntry 4 } ddsLoopbackConfig OBJECT-TYPE SYNTAX INTEGER { ddsNoLoop (1), ddsLineLoop (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents the loop-back configuration of the DDS interface. ddsNoLoop means the interface is not in loop-back state, and LineLoop means the the received data is looped back out." ::= { ddsConfigEntry 5 } ddsLineStatus OBJECT-TYPE SYNTAX INTEGER { ddsNoAlarm (1), ddsLossOfSignal (2), ddsOutOfService (3), ddsOutOfFrame (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This describes the current operational status of DDS line." ::= { ddsConfigEntry 6 } ddsTxClockSource OBJECT-TYPE SYNTAX INTEGER { ddsLoopTiming (1), ddsLocalTiming (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The source of Transmit clock. ddsLoopTiming - indicates that the recovered receive clock is used as transmit clock. ddsLocalTiming - indicates that a local clock source is used." ::= { ddsConfigEntry 7 } ddsPortInSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " This variable describes the current operational receive speed of DDS line. It is a read only value based entirely on DDS type (CC or PRI)." ::= { ddsConfigEntry 8 } ddsPortOutSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable describes the current operational transmit speed of DDS line. It is a read only value based entirely on DDS type CC or PRI" ::= { ddsConfigEntry 9 } -- -- Wan Alarms Group -- This group is required for any platforms that support -- Cabletron's WAN Alarm processing functionality -- -- -- DS1 Alarms Global Configuration Variables -- -- These parameters apply globally to the DS1 Alarms -- entity. These variables allow the user to program -- DS1 alarm characteristics to be the same for all DS1 -- lines installed in the device. The other option -- available to the user would be to configure each DS1 -- line individually, using the parameters in the DS1 -- Alarms Configuration Table. -- ds1AlarmsGlobalConfigGroup OBJECT IDENTIFIER ::= { ctDs1Alarms 1 } ds1AlarmGlobalAdmin OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- default enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm Monitoring Application for all DS1 circuits on the device." ::= { ds1AlarmsGlobalConfigGroup 1} ds1AlarmGlobalAutoRecovery OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) -- default } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm Automatic Recovery feature for all DS1 circuits on the device. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always returns disabled, and performs no action when written." ::= { ds1AlarmsGlobalConfigGroup 2} ds1AlarmGlobalTrapEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) -- default } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm SNMP Trap generation feature for all DS1 circuits on the device. This object operates in conjunction with configuration of objects in the ctron-trap-mib.txt" ::= { ds1AlarmsGlobalConfigGroup 3} ds1AlarmGlobalESCount OBJECT-TYPE SYNTAX INTEGER (1..300) -- default is 100 ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval." ::= { ds1AlarmsGlobalConfigGroup 4} ds1AlarmGlobalESInterval OBJECT-TYPE SYNTAX INTEGER (1..15) -- default is 6 minutes ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjuction with ds1AlarmGlobalESCount to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval." ::= { ds1AlarmsGlobalConfigGroup 5} ds1AlarmGlobalBPVErrorRate OBJECT-TYPE SYNTAX INTEGER (5..9) -- default is 6 ACCESS read-write STATUS mandatory DESCRIPTION "Used to specify the negative exponent of 10, used in monitoring Bipolar Violations (Code Violations for E1) over intervals defined by ds1AlarmGlobalBPVInterval. For example, for a ds1AlarmGlobalBPVErrorRate value of 6 used with a ds1AlarmGlobalBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written." ::= { ds1AlarmsGlobalConfigGroup 6} ds1AlarmGlobalBPVInterval OBJECT-TYPE SYNTAX INTEGER (1..15) -- default is 15 minutes ACCESS read-write STATUS mandatory DESCRIPTION "Used to specify the interval, used in monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmGlobalBPVErrorRate. For example, for a ds1AlarmGlobalBPVErrorRate value of 6 used with a ds1AlarmGlobalBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not detect bipolar violations, this object always returns the default, and performs no action when written." ::= { ds1AlarmsGlobalConfigGroup 7} ds1AlarmGlobalManualRecovery OBJECT-TYPE SYNTAX INTEGER { recover(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To cause a manual recovery to occur on all Ds1 circuits, this object is set to a 1. It is always read as a 1. The recovery will occur only when automatic recovery is disabled." ::= { ds1AlarmsGlobalConfigGroup 8} -- -- DS1 Alarms Configuration Table -- -- The DS1 alarm table structure contains the same information as the -- global configuration objects, but allows seperate configuratoin of -- specific DS1 circuits contained on the device -- ds1AlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Ds1AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing objects used to configure DS1 alarm functionality on a per DS1 basis." ::= { ctDs1Alarms 2 } ds1AlarmConfigEntry OBJECT-TYPE SYNTAX Ds1AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a single entry." INDEX { ds1PhysNum } ::= { ds1AlarmConfigTable 1 } Ds1AlarmConfigEntry ::= SEQUENCE { ds1PhysNum INTEGER, ds1AlarmAdmin INTEGER, ds1AlarmAutoRecovery INTEGER, ds1AlarmTrapEnable INTEGER, ds1AlarmESCount INTEGER, ds1AlarmESInterval INTEGER, ds1AlarmBPVErrorRate INTEGER, ds1AlarmBPVInterval INTEGER, ds1AlarmManualRecovery INTEGER } ds1PhysNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value for this object is equal to the value of a unique physical connection identifier associated with this DS1 which is clearly labeled on the device. For those products that do not have a DS1 identifier labeled on the device, the value for this object is the same as rfc1406 dsx1LineIndex." ::= { ds1AlarmConfigEntry 1 } ds1AlarmAdmin OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- default enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm Monitoring Application for this DS1 circuit." ::= { ds1AlarmConfigEntry 2} ds1AlarmAutoRecovery OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) -- default } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm Automatic Recovery feature for this DS1 circuit. For those devices that support ds1 alarm monitoring, but do not support the automatic recovery feature, this object always returns disabled, and performs no action when written." ::= { ds1AlarmConfigEntry 3} ds1AlarmTrapEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) -- default } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the DS1 Alarm SNMP Trap generation feature for this DS1 circuit. This object operates in conjunction with configuration of objects in the ctron-trap-mib.txt" ::= { ds1AlarmConfigEntry 4} ds1AlarmESCount OBJECT-TYPE SYNTAX INTEGER (1..300) -- default is 100 ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval." ::= { ds1AlarmConfigEntry 5} ds1AlarmESInterval OBJECT-TYPE SYNTAX INTEGER (1..15) -- default is 6 minutes ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjuction with ctDs1AlarmESCount to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval." ::= { ds1AlarmConfigEntry 6} ds1AlarmBPVErrorRate OBJECT-TYPE SYNTAX INTEGER (5..9) -- default is 6 ACCESS read-write STATUS mandatory DESCRIPTION "Used to specify the negative exponent of 10, used in monitoring Bipolar Violations (Code Violations for E1) over intervals defined by ds1AlarmBPVInterval. For example, for a ds1AlarmBPVErrorRate value of 6 used with a ds1AlarmBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written." ::= { ds1AlarmConfigEntry 7} ds1AlarmBPVInterval OBJECT-TYPE SYNTAX INTEGER (1..15) -- default is 15 minutes ACCESS read-write STATUS mandatory DESCRIPTION "Used to specify the interval, used in monitoring Bipolar Violations (Code Violations for E1) with thresholds defined by ds1AlarmBPVErrorRate. For example, for a ds1AlarmBPVErrorRate value of 6 used with a ds1AlarmBPVInterval of 15, an alarm is generated when a 15 minute period has an average error rate which exceeds 1 Bipolar Violation (Code Violation for E1) per million bits. For those devices that support ds1 alarm monitoring but who's hardware does not support detect bipolar violations, this object always returns the default, and performs no action when written." ::= { ds1AlarmConfigEntry 8} ds1AlarmManualRecovery OBJECT-TYPE SYNTAX INTEGER { recover(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To cause a manual recovery to occur, this object is set to a 1. It is always read as a 1. The recovery will occur only when automatic recovery is disabled." ::= { ds1AlarmConfigEntry 9} -- -- Wan Internet Protocol Priority Queue Filters Group -- This group is required for any platforms that support -- Cabletron's WAN IP Priority Queue processing functionality -- -- -- IP PQ Configuration Variables -- -- These parameters apply to the IP Priority Queue -- entity. These variables allow the user to program -- IP addresses in a filtering database. The database -- of IP addresses are used when a WAN service is over -- subscribed, and the packet would normally be discarded. -- If the IP PQ admin status is enabled, and the IP -- address of the packet to be discarded matches one -- programmed in the database, an attempt will be made -- to use high priority, reserved, resources to transmit -- the packet. The addresses programmed in this table -- should be reserved for those packets which MUST be -- transmitted. Some examples would be RIP, and SNMP -- packets, who's loss would cause major networking -- problems for the system. -- ipPQConfigGroup OBJECT IDENTIFIER ::= { ctIPPQFilters 1 } ipPQAdmin OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- default enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable and disable the IP Priority Queue Forwarding Application." ::= { ipPQConfigGroup 1} iPPQMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Returns the maximum number of IP address entries supported by the IP Priority Queue application on this device." ::= { ipPQConfigGroup 2} iPPQNumEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Get the number of IP address entries currently programmed in the ipPQAddressTable." ::= { ipPQConfigGroup 3} iPPQAddAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Add an IP address to the ipPQAddressTable. Always read as a 0.0.0.0." ::= { ipPQConfigGroup 4 } iPPQDelAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Delete an IP address from the ipPQAddressTable. Always read as a 0.0.0.0." ::= { ipPQConfigGroup 5 } -- -- -- -- IP Priority Queue Address Table -- -- The IP PQ table contains a list of IP adresses used with the -- Priority Queue filtering mechanism. -- ipPQAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF IpPQAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing IP addresses, used in an IP Priority Queue Forwarding function." ::= { ctIPPQFilters 2 } ipPQAddressEntry OBJECT-TYPE SYNTAX IpPQAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A description of a single entry." INDEX { ipPQAddressId } ::= { ipPQAddressTable 1 } IpPQAddressEntry ::= SEQUENCE { ipPQAddressId INTEGER, ipPQIPAddress IpAddress } ipPQAddressId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value identifying an element in a sequence of IP PQ address entries." ::= { ipPQAddressEntry 1 } ipPQIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Returns an IP address associated with a specific entry in this table." ::= { ipPQAddressEntry 2 } -- -- HDSL 15 Minute Performance History Table -- This group provides counters for UnAvailable Seconds and -- Errored Seconds of all HDSL connections -- ctWanHDSLPerformance15mTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLPerformance15mEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HDSL 15 minute performance table. This table provides the accumulated counts of errored seconds (ES) and unavailable seconds (UAS) for the HDSL line including the local, remote units and any doublers in between during a 15 minutes period for the last 24 hours. The table is indexed by the non-empty slot in the device and the 15-minute history slot within the last 24 hours period." ::= { ctWanHDSLExt 1 } ctWanHDSLPerformance15mEntry OBJECT-TYPE SYNTAX CtWanHDSLPerformance15mEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 15 minute performance table" INDEX { ctWanHDSLPerformance15mConnIndex, ctWanHDSLPerformance15mSlotIndex } ::= { ctWanHDSLPerformance15mTable 1 } CtWanHDSLPerformance15mEntry ::= SEQUENCE { ctWanHDSLPerformance15mConnIndex INTEGER, ctWanHDSLPerformance15mSlotIndex INTEGER, ctWanHDSLHLULoop1UAS15m INTEGER, ctWanHDSLHLULoop1ES15m INTEGER, ctWanHDSLHLULoop2UAS15m INTEGER, ctWanHDSLHLULoop2ES15m INTEGER, ctWanHDSLHRULoop1UAS15m INTEGER, ctWanHDSLHRULoop1ES15m INTEGER, ctWanHDSLHRULoop2UAS15m INTEGER, ctWanHDSLHRULoop2ES15m INTEGER, ctWanHDSLDb1NetworkLoop1UAS15m INTEGER, ctWanHDSLDb1NetworkLoop1ES15m INTEGER, ctWanHDSLDb1NetworkLoop2UAS15m INTEGER, ctWanHDSLDb1NetworkLoop2ES15m INTEGER, ctWanHDSLDb1CustomerLoop1UAS15m INTEGER, ctWanHDSLDb1CustomerLoop1ES15m INTEGER, ctWanHDSLDb1CustomerLoop2UAS15m INTEGER, ctWanHDSLDb1CustomerLoop2ES15m INTEGER, ctWanHDSLDb2NetworkLoop1UAS15m INTEGER, ctWanHDSLDb2NetworkLoop1ES15m INTEGER, ctWanHDSLDb2NetworkLoop2UAS15m INTEGER, ctWanHDSLDb2NetworkLoop2ES15m INTEGER, ctWanHDSLDb2CustomerLoop1UAS15m INTEGER, ctWanHDSLDb2CustomerLoop1ES15m INTEGER, ctWanHDSLDb2CustomerLoop2UAS15m INTEGER, ctWanHDSLDb2CustomerLoop2ES15m INTEGER } ctWanHDSLPerformance15mConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify the HDSL connection within the device, indexing from 1 to the maximum allowed number of HDSL connections in the device." ::= { ctWanHDSLPerformance15mEntry 1 } ctWanHDSLPerformance15mSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Define which 15-minute slot history of the HDSL within the 24 hour period. Indexing from 1 - 97 with the first index representing the current 15-minute history" ::= { ctWanHDSLPerformance15mEntry 2 } -- -- Local line unit's 15 minute performance history -- ctWanHDSLHLULoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the local line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 3 } ctWanHDSLHLULoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the local line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 4 } ctWanHDSLHLULoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the local line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 5 } ctWanHDSLHLULoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the local line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 6 } -- -- Remote line unit's 15-minute performance history -- ctWanHDSLHRULoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the remote line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 7 } ctWanHDSLHRULoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the remote line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 8 } ctWanHDSLHRULoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the remote line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 9 } ctWanHDSLHRULoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the remote line unit during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 10 } -- -- Doubler 1's 15-minute performance history -- ctWanHDSLDb1NetworkLoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 11 } ctWanHDSLDb1NetworkLoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the first doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 12 } ctWanHDSLDb1NetworkLoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 13 } ctWanHDSLDb1NetworkLoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the first doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 14 } ctWanHDSLDb1CustomerLoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 15 } ctWanHDSLDb1CustomerLoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the first doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 16 } ctWanHDSLDb1CustomerLoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 17 } ctWanHDSLDb1CustomerLoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the first doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 18 } -- -- Doubler 2's 15-minute performance history -- ctWanHDSLDb2NetworkLoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 19 } ctWanHDSLDb2NetworkLoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 20 } ctWanHDSLDb2NetworkLoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 21 } ctWanHDSLDb2NetworkLoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 22 } ctWanHDSLDb2CustomerLoop1UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 23 } ctWanHDSLDb2CustomerLoop1ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the second doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 24 } ctWanHDSLDb2CustomerLoop2UAS15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 25 } ctWanHDSLDb2CustomerLoop2ES15m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the second doubler unit's customer side during the 15-minute period." ::= { ctWanHDSLPerformance15mEntry 26 } -- -- HDSL 24 hour Performance History Table -- This group provides counters for UnAvailable Seconds and -- Errored Seconds of all HDSL connections -- ctWanHDSLPerformance24hTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLPerformance24hEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HDSL 24-hour performance table. This table provides the accumulated counts of errored seconds (ES) and unavailable seconds (UAS) for the HDSL line including the local, remote units and any doublers in between during a 24-hour period for the last 7 days. The table is indexed by the non-empty slot in the device and the 24-hour history slot within the last 7 days period." ::= { ctWanHDSLExt 2 } ctWanHDSLPerformance24hEntry OBJECT-TYPE SYNTAX CtWanHDSLPerformance24hEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 24-hour ctWanHDSLPerformance table" INDEX { ctWanHDSLPerformance24hConnIndex, ctWanHDSLPerformance24hSlotIndex } ::= { ctWanHDSLPerformance24hTable 1 } CtWanHDSLPerformance24hEntry ::= SEQUENCE { ctWanHDSLPerformance24hConnIndex INTEGER, ctWanHDSLPerformance24hSlotIndex INTEGER, ctWanHDSLHLULoop1UAS24h INTEGER, ctWanHDSLHLULoop1ES24h INTEGER, ctWanHDSLHLULoop2UAS24h INTEGER, ctWanHDSLHLULoop2ES24h INTEGER, ctWanHDSLHRULoop1UAS24h INTEGER, ctWanHDSLHRULoop1ES24h INTEGER, ctWanHDSLHRULoop2UAS24h INTEGER, ctWanHDSLHRULoop2ES24h INTEGER, ctWanHDSLDb1NetworkLoop1UAS24h INTEGER, ctWanHDSLDb1NetworkLoop1ES24h INTEGER, ctWanHDSLDb1NetworkLoop2UAS24h INTEGER, ctWanHDSLDb1NetworkLoop2ES24h INTEGER, ctWanHDSLDb1CustomerLoop1UAS24h INTEGER, ctWanHDSLDb1CustomerLoop1ES24h INTEGER, ctWanHDSLDb1CustomerLoop2UAS24h INTEGER, ctWanHDSLDb1CustomerLoop2ES24h INTEGER, ctWanHDSLDb2NetworkLoop1UAS24h INTEGER, ctWanHDSLDb2NetworkLoop1ES24h INTEGER, ctWanHDSLDb2NetworkLoop2UAS24h INTEGER, ctWanHDSLDb2NetworkLoop2ES24h INTEGER, ctWanHDSLDb2CustomerLoop1UAS24h INTEGER, ctWanHDSLDb2CustomerLoop1ES24h INTEGER, ctWanHDSLDb2CustomerLoop2UAS24h INTEGER, ctWanHDSLDb2CustomerLoop2ES24h INTEGER } -- -- Local line unit's 24-hour performance history -- ctWanHDSLPerformance24hConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify the HDSL connection within the device, indexing from 1 to the maximum allowed number of HDSL connections in the device." ::= { ctWanHDSLPerformance24hEntry 1 } ctWanHDSLPerformance24hSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Define which 24-hour slot history of the HDSL within the last 7 days period. Indexing from 1 - 8 with the first index representing the current 24 hour history" ::= { ctWanHDSLPerformance24hEntry 2 } ctWanHDSLHLULoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the local line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 3 } ctWanHDSLHLULoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the local line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 4 } ctWanHDSLHLULoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the local line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 5 } ctWanHDSLHLULoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the local line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 6 } -- -- Remote line unit's 24 hour performance history -- ctWanHDSLHRULoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the remote line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 7 } ctWanHDSLHRULoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the remote line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 8 } ctWanHDSLHRULoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the remote line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 9 } ctWanHDSLHRULoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the remote line unit during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 10 } -- -- Doubler 1's 15-minute performance history -- ctWanHDSLDb1NetworkLoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 11 } ctWanHDSLDb1NetworkLoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the first doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 12 } ctWanHDSLDb1NetworkLoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 13 } ctWanHDSLDb1NetworkLoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the first doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 14 } ctWanHDSLDb1CustomerLoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 15 } ctWanHDSLDb1CustomerLoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the first doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 16 } ctWanHDSLDb1CustomerLoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 17 } ctWanHDSLDb1CustomerLoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the first doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 18 } -- -- Doubler 2's 24-hour performance history -- ctWanHDSLDb2NetworkLoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 19 } ctWanHDSLDb2NetworkLoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the second doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 20 } ctWanHDSLDb2NetworkLoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 21 } ctWanHDSLDb2NetworkLoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the second doubler unit's network side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 22 } ctWanHDSLDb2CustomerLoop1UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 23 } ctWanHDSLDb2CustomerLoop1ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 1 of the second doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 24 } ctWanHDSLDb2CustomerLoop2UAS24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 25 } ctWanHDSLDb2CustomerLoop2ES24h OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Errored seconds (ES) on LOOP 2 of the second doubler unit's customer side during the 24-hour period." ::= { ctWanHDSLPerformance24hEntry 26 } ---------------------------------------------------- -- HDSL Statistics Table -- This group provides HDSL line statistics ---------------------------------------------------- ctWanHDSLStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table collects the statistics for the Signal noise ratio (SNR), and the pulse attenuation of the HDSL line, including the local, remote units and the doublers in between." ::= { ctWanHDSLExt 3 } ctWanHDSLStatisticsEntry OBJECT-TYPE SYNTAX CtWanHDSLStatisticsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of the HDSL statistics table " INDEX { ctWanHDSLStatisticsHLUConnIndex } ::= { ctWanHDSLStatisticsTable 1 } CtWanHDSLStatisticsEntry ::= SEQUENCE { ctWanHDSLStatisticsHLUConnIndex INTEGER, ctWanHDSLSNRHLULoop1 INTEGER, ctWanHDSLSNRLowHLULoop1 INTEGER, ctWanHDSLSNRHighHLULoop1 INTEGER, ctWanHDSLSNRHLULoop2 INTEGER, ctWanHDSLSNRLowHLULoop2 INTEGER, ctWanHDSLSNRHighHLULoop2 INTEGER, ctWanHDSLPulseAttenuationHLULoop1 INTEGER, ctWanHDSLPulseAttenuationHLULoop2 INTEGER, ctWanHDSLBitStat1HLU INTEGER, ctWanHDSLSNRHRULoop1 INTEGER, ctWanHDSLSNRLowHRULoop1 INTEGER, ctWanHDSLSNRHighHRULoop1 INTEGER, ctWanHDSLSNRHRULoop2 INTEGER, ctWanHDSLSNRLowHRULoop2 INTEGER, ctWanHDSLSNRHighHRULoop2 INTEGER, ctWanHDSLPulseAttenuationHRULoop1 INTEGER, ctWanHDSLPulseAttenuationHRULoop2 INTEGER, ctWanHDSLDs1FrameHRU INTEGER, ctWanHDSLSNRDb1NetworkLoop1 INTEGER, ctWanHDSLSNRLowDb1NetworkLoop1 INTEGER, ctWanHDSLSNRHighDb1NetworkLoop1 INTEGER, ctWanHDSLSNRDb1NetworkLoop2 INTEGER, ctWanHDSLSNRLowDb1NetworkLoop2 INTEGER, ctWanHDSLSNRHighDb1NetworkLoop2 INTEGER, ctWanHDSLSNRDb1CustomerLoop1 INTEGER, ctWanHDSLSNRLowDb1CustomerLoop1 INTEGER, ctWanHDSLSNRHighDb1CustomerLoop1 INTEGER, ctWanHDSLSNRDb1CustomerLoop2 INTEGER, ctWanHDSLSNRLowDb1CustomerLoop2 INTEGER, ctWanHDSLSNRHighDb1CustomerLoop2 INTEGER, ctWanHDSLPulseAttenuationDb1NetworkLoop1 INTEGER, ctWanHDSLPulseAttenuationDb1NetworkLoop2 INTEGER, ctWanHDSLPulseAttenuationDb1CustomerLoop1 INTEGER, ctWanHDSLPulseAttenuationDb1CustomerLoop2 INTEGER, ctWanHDSLSNRDb2NetworkLoop1 INTEGER, ctWanHDSLSNRLowDb2NetworkLoop1 INTEGER, ctWanHDSLSNRHighDb2NetworkLoop1 INTEGER, ctWanHDSLSNRDb2NetworkLoop2 INTEGER, ctWanHDSLSNRLowDb2NetworkLoop2 INTEGER, ctWanHDSLSNRHighDb2NetworkLoop2 INTEGER, ctWanHDSLSNRDb2CustomerLoop1 INTEGER, ctWanHDSLSNRLowDb2CustomerLoop1 INTEGER, ctWanHDSLSNRHighDb2CustomerLoop1 INTEGER, ctWanHDSLSNRDb2CustomerLoop2 INTEGER, ctWanHDSLSNRLowDb2CustomerLoop2 INTEGER, ctWanHDSLSNRHighDb2CustomerLoop2 INTEGER, ctWanHDSLPulseAttenuationDb2NetworkLoop1 INTEGER, ctWanHDSLPulseAttenuationDb2NetworkLoop2 INTEGER, ctWanHDSLPulseAttenuationDb2CustomerLoop1 INTEGER, ctWanHDSLPulseAttenuationDb2CustomerLoop2 INTEGER } -- -- Local line unit's statistics -- ctWanHDSLStatisticsHLUConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify the HDSL connection occupied in the device, indexing from 1 to the maximum allowed connections in the device." ::= { ctWanHDSLStatisticsEntry 1 } ctWanHDSLSNRHLULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of the local line unit." ::= { ctWanHDSLStatisticsEntry 2 } ctWanHDSLSNRLowHLULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of the local line unit." ::= { ctWanHDSLStatisticsEntry 3 } ctWanHDSLSNRHighHLULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of the local line unit." ::= { ctWanHDSLStatisticsEntry 4 } ctWanHDSLSNRHLULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of the local line unit." ::= { ctWanHDSLStatisticsEntry 5 } ctWanHDSLSNRLowHLULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of the local line unit." ::= { ctWanHDSLStatisticsEntry 6 } ctWanHDSLSNRHighHLULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of the local line unit." ::= { ctWanHDSLStatisticsEntry 7 } ctWanHDSLPulseAttenuationHLULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 1 of the local line unit." ::= { ctWanHDSLStatisticsEntry 8 } ctWanHDSLPulseAttenuationHLULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 2 of the local line unit." ::= { ctWanHDSLStatisticsEntry 9 } ctWanHDSLBitStat1HLU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A byte value which contains product specific information: bit 0 - System in AIS on the local line unit. 1 - System in AIS on the remote line unit. 2 - Channels are reversed on the remote line unit. 3 - Channels are reversed on the doubler 1. 4 - Channels are reversed on the doubler 2. 5 - Power is fed to the next unit on the local line unit. 6 - Power is fed to the next unit on the remote line unit. 7 - Smartloop is active on remote line unit. (HiGain only)" ::= { ctWanHDSLStatisticsEntry 10 } -- -- Remote line unit's statistics -- ctWanHDSLSNRHRULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 11 } ctWanHDSLSNRLowHRULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 12 } ctWanHDSLSNRHighHRULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 13 } ctWanHDSLSNRHRULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 14 } ctWanHDSLSNRLowHRULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 15 } ctWanHDSLSNRHighHRULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 16 } ctWanHDSLPulseAttenuationHRULoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 1 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 17 } ctWanHDSLPulseAttenuationHRULoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 2 of the remote line unit." ::= { ctWanHDSLStatisticsEntry 18 } ctWanHDSLDs1FrameHRU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Byte value shows DS1 frame and code information for the remote line unit (HiGain only): bit 0:1 - 0 - frame format is SF. 1 - frame format is ESF. 2 - Frame format is unframed. 3 - no activity. bit 2:3 - reserved. bit 4 - 0 - line code is AMI 1 - line code is B8ZS. bit 5:7 - reserved." ::= { ctWanHDSLStatisticsEntry 19 } -- -- Doubler 1's statistics -- ctWanHDSLSNRDb1NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of doubler 1's network side" ::= { ctWanHDSLStatisticsEntry 20 } ctWanHDSLSNRLowDb1NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of doubler 1's network side" ::= { ctWanHDSLStatisticsEntry 21 } ctWanHDSLSNRHighDb1NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of doubler 1's network side" ::= { ctWanHDSLStatisticsEntry 22 } ctWanHDSLSNRDb1NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of doubler 1's network side." ::= { ctWanHDSLStatisticsEntry 23 } ctWanHDSLSNRLowDb1NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of doubler 1's network side." ::= { ctWanHDSLStatisticsEntry 24 } ctWanHDSLSNRHighDb1NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of doubler 1's network side." ::= { ctWanHDSLStatisticsEntry 25 } ctWanHDSLSNRDb1CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 26 } ctWanHDSLSNRLowDb1CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 27 } ctWanHDSLSNRHighDb1CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 28 } ctWanHDSLSNRDb1CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 29 } ctWanHDSLSNRLowDb1CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 30 } ctWanHDSLSNRHighDb1CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 31 } ctWanHDSLPulseAttenuationDb1NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 1 of doubler 1's network side." ::= { ctWanHDSLStatisticsEntry 32 } ctWanHDSLPulseAttenuationDb1NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 2 of doubler 1's network side." ::= { ctWanHDSLStatisticsEntry 33 } ctWanHDSLPulseAttenuationDb1CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 1 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 34 } ctWanHDSLPulseAttenuationDb1CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 2 of doubler 1's customer side." ::= { ctWanHDSLStatisticsEntry 35 } -- -- Doubler 2's Statistics -- ctWanHDSLSNRDb2NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 36 } ctWanHDSLSNRLowDb2NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 37 } ctWanHDSLSNRHighDb2NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 38 } ctWanHDSLSNRDb2NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 39 } ctWanHDSLSNRLowDb2NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 40 } ctWanHDSLSNRHighDb2NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 41 } ctWanHDSLSNRDb2CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 1 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 42 } ctWanHDSLSNRLowDb2CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 1 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 43 } ctWanHDSLSNRHighDb2CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 1 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 44 } ctWanHDSLSNRDb2CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current SNR on LOOP 2 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 45 } ctWanHDSLSNRLowDb2CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lowest SNR on LOOP 2 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 46 } ctWanHDSLSNRHighDb2CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Highest SNR on LOOP 2 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 47 } ctWanHDSLPulseAttenuationDb2NetworkLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 1 of doubler 2's network side" ::= { ctWanHDSLStatisticsEntry 48 } ctWanHDSLPulseAttenuationDb2NetworkLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 2 of doubler 2's network side." ::= { ctWanHDSLStatisticsEntry 49 } ctWanHDSLPulseAttenuationDb2CustomerLoop1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "pulse Attenuation on LOOP 1 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 50 } ctWanHDSLPulseAttenuationDb2CustomerLoop2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Pulse Attenuation on LOOP 2 of doubler 2's customer side." ::= { ctWanHDSLStatisticsEntry 51 } ---------------------------------------------------- -- HDSL Test Table ---------------------------------------------------- ctWanHDSLTestTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Test result for the HDSL line, the current test results only apply to the local line unit. " ::= { ctWanHDSLExt 4 } ctWanHDSLTestEntry OBJECT-TYPE SYNTAX CtWanHDSLTestEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries of the HDSL test results table." INDEX { ctWanHDSLTestHLUConnIndex } ::= { ctWanHDSLTestTable 1 } CtWanHDSLTestEntry ::= SEQUENCE { ctWanHDSLTestHLUConnIndex INTEGER, ctWanHDSLTestMode INTEGER, ctWanHDSLHLUTestResult INTEGER, ctWanHDSLHRUTestResult INTEGER } ctWanHDSLTestHLUConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify the slot of the HDSL within the device that the user wants to conduct the line unit test. Slot number start from 1 to maximum slots available in the device." ::= { ctWanHDSLTestEntry 1 } ctWanHDSLTestMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object may only be successfully set on a master device. When this object is set, the local unit's test mode is defined by these values when set: 1 - Normal operation 3 - Self test mode 4 - PROM check test 5 - External RAM test 6 - DS1 loop test 7 - MUX-DMUX test 9 - Analog loopback mode 13 - Transceiver mode When getting this object, the value returned represents the last value this object had been set to." ::= { ctWanHDSLTestEntry 2 } ctWanHDSLHLUTestResult OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Test result for the local line unit (1 - test failed, 0 - success): bit 0 - 2180 DS1 frame sync test (HiGain only) 1 - 2180 DS1 data test (HiGain only) 2 - LIU DS1 frame sync test (HiGain only) 3 - LIU DS1 data test (HiGain only) 4 - External DS1 frame sync test (HiGain only) 5 - External DS1 data test. 6 - Mux sync test on HDSL LOOP 1 7 - Mux sync test on HDSL LOOP 2 8 - Reserved. 9 - Mux frame error test on HDSL LOOP 1 10 - Mux frame error test on HDSL LOOP 2 11 - Mux CRC test on HDSL LOOP 1 12 - Mux CRC test on HDSL LOOP 2 13 - Mux DL test on HDSL LOOP 1 14 - Mux DL test on HDSL LOOP 2 15 - Analog loopback test. 16 - Digital loop test. 17 - HGF HDSL loop test (HiGain only) 18 - HGF write/readback test (HiGain only) 19 - HGF poll lock test (HiGain only). 20 - HGF activity monitor test (HiGain only). 21 - HGF zeroes TX and detect test (HiGain only). 22 - HGF ones TX and detect test (HiGain only). 23 - Transceiver poll test on HDSL LOOP 1 24 - Transceiver poll test on HDSL LOOP 2 25 - PROM check test. 26 - External RAM test. 27 - Non-Volatile RAM test. " ::= { ctWanHDSLTestEntry 3 } ctWanHDSLHRUTestResult OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Test results for the remote line unit, Bit definitions correspond to those defined for ctWanHDSLHLUTestResult. " ::= { ctWanHDSLTestEntry 4 } ---------------------------------------------------- -- HDSL Alarms Table ---------------------------------------------------- ctWanHDSLAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLAlarmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table collects the existing alarms information for the HDSL line, including the local, remote line units and the doublers." ::= { ctWanHDSLExt 5 } ctWanHDSLAlarmsEntry OBJECT-TYPE SYNTAX CtWanHDSLAlarmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries for the ctWanHDSL alarms information" INDEX { ctWanHDSLAlarmsHLUConnIndex } ::= { ctWanHDSLAlarmsTable 1 } CtWanHDSLAlarmsEntry ::= SEQUENCE { ctWanHDSLAlarmsHLUConnIndex INTEGER, ctWanHDSLAlarmsBackplane INTEGER, ctWanHDSLAlarmsES INTEGER } ctWanHDSLAlarmsHLUConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify which HDSL connection within the device that the user wants to retrieve the alarm information." ::= { ctWanHDSLAlarmsEntry 1 } ctWanHDSLAlarmsBackplane OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specific information that's related to the HDSL alarms, each bit in the two bytes value has the following meaning if set: Bit 0 : Local Loss of Signal on DS1 line (HiGain only). 1 : Remote Loss of Signal on DS1 list (HiGain only). 2 - 7 : reserved. 8 : Loss of Sync word on LOOP 1 of the local line unit. 9 : Loss of Sync word on LOOP 2 of the local line unit. 10 : Loss of Sync word on LOOP 1 of the first doubler. 11 : Loss of sync word on LOOP 2 of the first doubler. 12 : Loss of Sync word on LOOP 1 of the second doubler. 13 : Loss of sync word on LOOP 2 of the second doubler." ::= { ctWanHDSLAlarmsEntry 2 } ctWanHDSLAlarmsES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A two bytes value for the Errored Second indication of the HDSL line unit, including local, remote line units and the doublers. each bit in the two bytes value has the following meaning if set: Bit 0 : Errored Second on LOOP 1 of local line unit. 1 : Errored Second on LOOP 2 of local line unit. 2 : Errored Second on LOOP 1 of remote line unit. 3 : Errored Second on LOOP 2 of remote line unit. 4 : Errored Second on LOOP 1 of local line unit's network side. 5 : Errored Second on LOOP 2 of local line unit's network side. 6 : Errored Second on LOOP 1 of local line unit's customer side. 7 : Errored Second on LOOP 2 of local line unit's customer side." ::= { ctWanHDSLAlarmsEntry 3 } ---------------------------------------------------- -- HDSL Alarm History Table ---------------------------------------------------- ctWanHDSLAlarmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HDSL Alarm History table. This table provides the accumulated counts of Errored Seconds (ES) and Loss of Sync words (LOS) as well as the time stamp of the above events occurred for both of the HDSL loops. The time stamps show the date in MMDDYYYYHHMM format." ::= { ctWanHDSLExt 6 } ctWanHDSLAlarmHistoryEntry OBJECT-TYPE SYNTAX CtWanHDSLAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the Alarm History table" INDEX { ctWanHDSLAlarmHistoryConnIndex } ::= { ctWanHDSLAlarmHistoryTable 1 } CtWanHDSLAlarmHistoryEntry ::= SEQUENCE { ctWanHDSLAlarmHistoryConnIndex INTEGER, ctWanHDSLAlHistLLOSFirst DisplayString(SIZE(12)), ctWanHDSLAlHistLLOSLast DisplayString(SIZE(12)), ctWanHDSLAlHistLLOSCurrent INTEGER, ctWanHDSLAlHistLLOSCount INTEGER, ctWanHDSLAlHistRLOSFirst DisplayString(SIZE(12)), ctWanHDSLAlHistRLOSLast DisplayString(SIZE(12)), ctWanHDSLAlHistRLOSCurrent INTEGER, ctWanHDSLAlHistRLOSCount INTEGER, ctWanHDSLAlHistLOSW1First DisplayString(SIZE(12)), ctWanHDSLAlHistLOSW1Last DisplayString(SIZE(12)), ctWanHDSLAlHistLOSW1Current INTEGER, ctWanHDSLAlHistLOSW1Count INTEGER, ctWanHDSLAlHistLOSW2First DisplayString(SIZE(12)), ctWanHDSLAlHistLOSW2Last DisplayString(SIZE(12)), ctWanHDSLAlHistLOSW2Current INTEGER, ctWanHDSLAlHistLOSW2Count INTEGER, ctWanHDSLAlHistES1First DisplayString(SIZE(12)), ctWanHDSLAlHistES1Last DisplayString(SIZE(12)), ctWanHDSLAlHistES1Current INTEGER, ctWanHDSLAlHistES1Count INTEGER, ctWanHDSLAlHistES2First DisplayString(SIZE(12)), ctWanHDSLAlHistES2Last DisplayString(SIZE(12)), ctWanHDSLAlHistES2Current INTEGER, ctWanHDSLAlHistES2Count INTEGER, ctWanHDSLAlHistMargin1First DisplayString(SIZE(12)), ctWanHDSLAlHistMargin1Last DisplayString(SIZE(12)), ctWanHDSLAlHistMargin1Current INTEGER, ctWanHDSLAlHistMargin1Count INTEGER, ctWanHDSLAlHistMargin2First DisplayString(SIZE(12)), ctWanHDSLAlHistMargin2Last DisplayString(SIZE(12)), ctWanHDSLAlHistMargin2Current INTEGER, ctWanHDSLAlHistMargin2Count INTEGER, ctWanHDSLAlHistCleared DisplayString(SIZE(12)), ctWanHDSLAlHistClearit INTEGER } ctWanHDSLAlarmHistoryConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines which HDSL connection's alarm history within the device." ::= { ctWanHDSLAlarmHistoryEntry 1 } ctWanHDSLAlHistLLOSFirst OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the DS1 Loss Of Signal (LOS) occurred on the local side of the HDSL." ::= { ctWanHDSLAlarmHistoryEntry 2 } ctWanHDSLAlHistLLOSLast OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred on the local side of the HDSL." ::= { ctWanHDSLAlarmHistoryEntry 3 } ctWanHDSLAlHistLLOSCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the DS1 Loss Of Signal (LOS) still occurred on the local side of the HDSL." ::= { ctWanHDSLAlarmHistoryEntry 4 } ctWanHDSLAlHistLLOSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the DS1 Loss Of Signal (LOS) occurred since we last cleared the alarm history on the local side of the HDSL. (HiGain only)" ::= { ctWanHDSLAlarmHistoryEntry 5 } ctWanHDSLAlHistRLOSFirst OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the DS1 Loss Of Signal (LOS) occurred on the remote side of the HDSL. (HiGain only)" ::= { ctWanHDSLAlarmHistoryEntry 6 } ctWanHDSLAlHistRLOSLast OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred on the remote side of the HDSL. (HiGain only)" ::= { ctWanHDSLAlarmHistoryEntry 7 } ctWanHDSLAlHistRLOSCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the DS1 Loss Of Signal (LOS) still occurred on the remote site of the HDSL. (HiGain only)" ::= { ctWanHDSLAlarmHistoryEntry 8 } ctWanHDSLAlHistRLOSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the DS1 Loss Of Signal (LOS) occurred since we last cleared the alarm history on the remote site of the HDSL. (HiGain only)" ::= { ctWanHDSLAlarmHistoryEntry 9 } ctWanHDSLAlHistLOSW1First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the Loss Of Sync Word (LOSW) occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 10 } ctWanHDSLAlHistLOSW1Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the Loss Of Sync Word (LOSW) occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 11 } ctWanHDSLAlHistLOSW1Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 12 } ctWanHDSLAlHistLOSW1Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the Loss Of Sync Word (LOSW) occurred since we last cleared the history on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 13 } ctWanHDSLAlHistLOSW2First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the Loss Of Sync Word (LOSW) occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 14 } ctWanHDSLAlHistLOSW2Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the Loss Of Sync Word (LOSW) occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 15 } ctWanHDSLAlHistLOSW2Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 16 } ctWanHDSLAlHistLOSW2Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the Loss Of Sync Word (LOSW) occurred since we last cleared the history on the LOOP 2 of the HDSL link. " ::= { ctWanHDSLAlarmHistoryEntry 17 } ctWanHDSLAlHistES1First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the Errored Seconds (ES) occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 18 } ctWanHDSLAlHistES1Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the Errored Seconds (ES) occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 19 } ctWanHDSLAlHistES1Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the Errored Seconds (ES) still occurred on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 20 } ctWanHDSLAlHistES1Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the Errored Seconds (ES) occurred since we last cleared the alarm history on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 21 } ctWanHDSLAlHistES2First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the Errored Seconds (ES) occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 22 } ctWanHDSLAlHistES2Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the Errored Seconds (ES) occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 23 } ctWanHDSLAlHistES2Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the Errored Seconds (ES) still occurred on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 24 } ctWanHDSLAlHistES2Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the Errored Seconds (ES) occurred since we last cleared the history on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 25 } ctWanHDSLAlHistMargin1First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the alarms exceeded the Margin Threshold on LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 26 } ctWanHDSLAlHistMargin1Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the alarms exceeded the Margin Threshold on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 27 } ctWanHDSLAlHistMargin1Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the alarms still exceeded the Margin Threshold on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 28 } ctWanHDSLAlHistMargin1Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the alarm exceeded the Margin Threshold since we last cleared the alarm history on the LOOP 1 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 29 } ctWanHDSLAlHistMargin2First OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the first time the alarms exceeded the Margin Threshold on LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 30 } ctWanHDSLAlHistMargin2Last OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the last time the alarms exceeded the Margin Threshold on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 31 } ctWanHDSLAlHistMargin2Current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Set if the alarms still exceeded the Margin Threshold on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 32 } ctWanHDSLAlHistMargin2Count OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times the alarm exceeded the Margin Threshold since we last cleared the alarm history on the LOOP 2 of the HDSL link." ::= { ctWanHDSLAlarmHistoryEntry 33 } ctWanHDSLAlHistCleared OBJECT-TYPE SYNTAX DisplayString(SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the time user requested to clear the alarm history." ::= { ctWanHDSLAlarmHistoryEntry 34 } ctWanHDSLAlHistClearit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "set to a 1 to clear the alarm history. A read of this value always returns a 1. NOTE: the setting of this object also causes the SNR low value, SNR high value, and the performance history to be reset." ::= { ctWanHDSLAlarmHistoryEntry 35 } ---------------------------------------------------- -- HDSL Loopbacks Table ---------------------------------------------------- ctWanHDSLLoopbacksTable OBJECT-TYPE SYNTAX SEQUENCE OF CtWanHDSLLoopbacksEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HDSL Loopback table. This table provides the certain loopback settings for the HDSL link." ::= { ctWanHDSLExt 7 } ctWanHDSLLoopbacksEntry OBJECT-TYPE SYNTAX CtWanHDSLLoopbacksEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the HDSL Loopback table." INDEX { ctWanHDSLLoopbacksHLUConnIndex } ::= { ctWanHDSLLoopbacksTable 1 } CtWanHDSLLoopbacksEntry ::= SEQUENCE { ctWanHDSLLoopbacksHLUConnIndex INTEGER, ctWanHDSLLoopbacksAdminType INTEGER, ctWanHDSLLoopbacksOperType INTEGER } ctWanHDSLLoopbacksHLUConnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identify the HDSL connection within the device" ::= { ctWanHDSLLoopbacksEntry 1 } ctWanHDSLLoopbacksAdminType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the requested loopback type for the HDSL. loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to network at remote line unit. 4 : Loopback to customer at local line unit. 5 : Loopback to customer at remote line unit. 6 : Loopback to customer at first doubler. 7 : Loopback to customer at second doubler. 8 : Loopback to network at first doubler. 9 : Loopback to network at second doubler. 10: No loopback (turn loopback off). " ::= { ctWanHDSLLoopbacksEntry 2 } ctWanHDSLLoopbacksOperType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the operational loopback type for the HDSL. loopbacks setting: 1 : Smartjack - loopback to network at remote line unit. 2 : Loopback to network at local line unit. 3 : Loopback to network at remote line unit. 4 : Loopback to customer at local line unit. 5 : Loopback to customer at remote line unit. 6 : Loopback to customer at first doubler. 7 : Loopback to customer at second doubler. 8 : Loopback to network at first doubler. 9 : Loopback to network at second doubler. 10: No loopback (turn loopback off). " ::= { ctWanHDSLLoopbacksEntry 3 } END