AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks Inc » CTSMTMIB-MIB

CTSMTMIB-MIB device MIB details by Enterasys Networks Inc

CTSMTMIB-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CTSMTMIB-MIB.


Vendor: Enterasys Networks Inc
Mib: CTSMTMIB-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
CTSMTMIB-MIB  DEFINITIONS ::= BEGIN

        --  Ctron SMT MIB
        --  Revision: 1.03.02
        --  Date: April 18, 1997
        --  Part Number:  2170563-01

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for part
        --  of the naming tree below:
        --
        --              cabletron { enterprises 52 }
        --
        --  This module will be extended, as additional sub-sections
        --  of this naming tree are defined.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems



     IMPORTS
             Counter
                 FROM RFC1155-SMI
             ctsmtmib
                FROM CTRON-MIB-NAMES
             OBJECT-TYPE
                 FROM RFC-1212;



     ctsmtmibRingTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF CtsmtmibRingEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "A list of fddi nodes found on the ring."
         ::= { ctsmtmib 1 }

     ctsmtmibRingEntry  OBJECT-TYPE
         SYNTAX  CtsmtmibRingEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "A fddi ring entry containing information common to all
                  stations in a token path."
         INDEX   { ctsmtmibRingSmtIndex, ctsmtmibRingMacIndex,
                   ctsmtmibRingNodeIndex, ctsmtmibRingMacAddr }
         ::= { ctsmtmibRingTable 1 }

     CtsmtmibRingEntry ::= SEQUENCE {
         ctsmtmibRingSmtIndex        INTEGER,
         ctsmtmibRingMacIndex        INTEGER,
         ctsmtmibRingNodeIndex       INTEGER,
         ctsmtmibRingMacAddr         OCTET STRING,
         ctsmtmibRingUpStreamAddr    OCTET STRING,
         ctsmtmibRingNodeClass       INTEGER,
         ctsmtmibRingMacCount        INTEGER,
         ctsmtmibRingNonMasterCount  INTEGER,
         ctsmtmibRingMasterCount     INTEGER,
         ctsmtmibRingTopology        INTEGER,
         ctsmtmibRingDuplicate       INTEGER
         }

     ctsmtmibRingSmtIndex  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The value of the SMT index associated with this ring."
         ::= { ctsmtmibRingEntry 1 }

     ctsmtmibRingMacIndex  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A unique value for each MAC within a given SMT."
         ::= { ctsmtmibRingEntry 2 }

     ctsmtmibRingNodeIndex  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The index of the node on the ring in reverse token
                  flow order. It is sequential from 1 to n where n is
                  the number of nodes on the ring at a given time."
         ::= { ctsmtmibRingEntry 3 }

     ctsmtmibRingMacAddr  OBJECT-TYPE
         SYNTAX  OCTET STRING
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A canonical representation of the MAC address of the
                  node."
         ::= { ctsmtmibRingEntry 4 }

     ctsmtmibRingUpStreamAddr  OBJECT-TYPE
         SYNTAX  OCTET STRING (SIZE (6))
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "This is a canonical representation of the upstream
                  neighbor's address. The upstream neighbor is the last
                  MAC to receive the token before this MAC. Unknown
                  addresses should be specified as 00-00-F8-00-00-00."
         ::= { ctsmtmibRingEntry 5 }

     ctsmtmibRingNodeClass  OBJECT-TYPE
         SYNTAX  INTEGER {
                     station (1),
                     concentrator (2)
                 }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "Reports if the node is a station or a concentrator."
         ::= { ctsmtmibRingEntry 6 }

     ctsmtmibRingMacCount  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The number of MACs on this FDDI node."
         ::= { ctsmtmibRingEntry 7 }

     ctsmtmibRingNonMasterCount  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The sum of all A ports, B ports, and S ports on this
                  node."
         ::= { ctsmtmibRingEntry 8 }

     ctsmtmibRingMasterCount  OBJECT-TYPE
         SYNTAX  INTEGER (0..255)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The number of master ports on this node."
         ::= { ctsmtmibRingEntry 9 }

     ctsmtmibRingTopology  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A bit mapped representation of the current state of
                  the node.
                  if state:                Add 2**n where n =
                  Wrapped Node                    0
                  Unattached Concentrator         1
                  A-A Twisted Ring                2
                  B-B Twisted Ring                3
                  Rooted Station                  4
                  SRF Supported                   5

                  where
                    Wrapped Node: is set when the node's cf-state is
                                  Wrap-A,  Wrap-B, Wrap-C, or Wrap-AB.
                    Unattached Concentrator: is set when a concentrator
                                  has no active A, B, or S ports.
                    A-A Twisted Ring: is set when this node's A port is
                                  connected to another A port.
                    B-B Twisted Ring: is set when this node's B port is
                                  connected to another B port.
                    Rooted Station: is a station with ports A, B and S,
                                  not active in tree mode.
                    SRF Supported: This node adheres to the status
                                  reporting frame protocol."
         ::= { ctsmtmibRingEntry 10 }

     ctsmtmibRingDuplicate  OBJECT-TYPE
         SYNTAX  INTEGER (0..2)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A bit mapped representation of duplicate address
                  information.

                  if State:                 Add 2**n where n=
                  My Duplicate:                     0
                  UNA Duplicate:                    1

                  where
                     My Duplicate: This node determines that it's MAC
                        address is same as the MAC address for another
                        node on the ring.
                     UNA Duplicate: The upstream neighbor of this node
                        has determined that its's MAC address is same as
                        the MAC address for another node on the ring."
         ::= { ctsmtmibRingEntry 11 }

     ctsmtmibMacTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF CtsmtmibMacEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "A list of MAC entries. The total number of entries is
                  given by the value of ctsmtmibRingMacCount with appropriate
                  ctsmtmibRingMacAddr."
         ::= { ctsmtmib 2 }

     ctsmtmibMacEntry  OBJECT-TYPE
         SYNTAX  CtsmtmibMacEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "A MAC entry containing information pertaining to a
                  given MAC."
         INDEX   { ctsmtmibMacSmtIndex, ctsmtmibMacIndex }
         ::= { ctsmtmibMacTable 1 }

     CtsmtmibMacEntry ::= SEQUENCE {
         ctsmtmibMacSmtIndex         INTEGER,
         ctsmtmibMacIndex            INTEGER,
         ctsmtmibMacNifTxCts         Counter,
         ctsmtmibMacNifRxCts         Counter,
         ctsmtmibMacSifTxCts         Counter,
         ctsmtmibMacSifRxCts         Counter,
         ctsmtmibMacEcfTxCts         Counter,
         ctsmtmibMacEcfRxCts         Counter,
         ctsmtmibMacPmfTxCts         Counter,
         ctsmtmibMacPmfRxCts         Counter,
         ctsmtmibMacRdfTxCts         Counter,
         ctsmtmibMacRdfRxCts         Counter,
         ctsmtmibMacRingOpCts        Counter,
         ctsmtmibMacTxCts            Counter,
         ctsmtmibMacRingMapUpdateCts Counter,
         ctsmtmibMacAutoNegotiation  INTEGER
         }

     ctsmtmibMacSmtIndex  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The value of the SMT Index associated with this MAC."
         ::= { ctsmtmibMacEntry 1 }

     ctsmtmibMacIndex  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A unique value for each MAC within a given SMT."
         ::= { ctsmtmibMacEntry 2 }

     ctsmtmibMacNifTxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Neighborhood Information frames
                  transmitted by the MAC."
         ::= { ctsmtmibMacEntry 3 }

     ctsmtmibMacNifRxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Neighborhood Information frames received
                  by the MAC."
         ::= { ctsmtmibMacEntry 4 }

     ctsmtmibMacSifTxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Status Information frames transmitted by
                  the MAC."
         ::= { ctsmtmibMacEntry 5 }

     ctsmtmibMacSifRxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Status Information Frames received by
                  the MAC."
         ::= { ctsmtmibMacEntry 6 }

     ctsmtmibMacEcfTxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Echo Frames transmitted by the MAC."
         ::= { ctsmtmibMacEntry 7 }

     ctsmtmibMacEcfRxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Echo Frames received by the MAC."
         ::= { ctsmtmibMacEntry 8 }

     ctsmtmibMacPmfTxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Parameter Management Frames transmitted
                  by the MAC."
         ::= { ctsmtmibMacEntry 9 }

     ctsmtmibMacPmfRxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Parameter Management Frames received by
                  the MAC."
         ::= { ctsmtmibMacEntry 10 }

     ctsmtmibMacRdfTxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Request Denied Frames transmitted by the
                  MAC."
         ::= { ctsmtmibMacEntry 11 }

     ctsmtmibMacRdfRxCts  OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of Request Denied Frames received by the MAC."
         ::= { ctsmtmibMacEntry 12 }

     ctsmtmibMacRingOpCts OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of the number of times the ring has entered
                  'Ring Operational' state from the 'Ring Not Operational'
                  state."
         ::= { ctsmtmibMacEntry 13 }

     ctsmtmibMacTxCts OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A count that should as closely as possible match the
                  number of frames transmitted by this MAC."
         ::= { ctsmtmibMacEntry 14 }

     ctsmtmibMacRingMapUpdateCts OBJECT-TYPE
         SYNTAX  Counter
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The count of the number of times the ring map table has
                  been updated."
         ::= { ctsmtmibMacEntry 15 }

     ctsmtmibMacAutoNegotiation  OBJECT-TYPE
         SYNTAX  INTEGER {
               true(1),
               false(2)
         } 
         ACCESS  read-write
         STATUS  mandatory
         DESCRIPTION
                 "Indicates whether the station has auto-negotiation
                  enabled or disabled."
         ::= { ctsmtmibMacEntry 16 }

     ctsmtmibAttachmentNumber  OBJECT-TYPE
         SYNTAX  INTEGER (0..65535)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The total number of attachments (across all SMTs) on
                  this network management application entity. The value
                  for this variable must remain constant at least from
                  one re-initialization of the entity's network
                  management system to the next re-initialization."
         ::= { ctsmtmib 3 }

     ctsmtmibAttachmentTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF CtsmtmibAttachmentEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "A list of Attachment entries. The number of entries is
                  given by the value of fdmimAttachmentNumber."
         ::= { ctsmtmib 4 }

     ctsmtmibAttachmentEntry  OBJECT-TYPE
         SYNTAX  CtsmtmibAttachmentEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
                 "An Attachment entry containing information common to a
                  given set of Attachments.

                  There is a natural association of Attachment resource
                  indices to the PORT Indices. The resource index for
                  the Attachment is equal to the associated port index
                  for 'single-attachment' and 'concentrator' type
                  fdmimAttachmentClasses. For 'dual-attachment' classes,
                  the Attachment Index is the PORT Index of the A PORT
                  of the A/B PORT pair that represents the Attachment."
         INDEX   { ctsmtmibAttachmentSMTIndex, ctsmtmibAttachmentIndex }
         ::= { ctsmtmibAttachmentTable 1 }

     CtsmtmibAttachmentEntry ::= SEQUENCE {
         ctsmtmibAttachmentSMTIndex              INTEGER,
         ctsmtmibAttachmentIndex                 INTEGER,
         ctsmtmibAttachmentClass                 INTEGER,
         ctsmtmibAttachmentOpticalBypassPresent  INTEGER,
         ctsmtmibAttachmentIMaxExpiration        INTEGER,
         ctsmtmibAttachmentInsertedStatus        INTEGER,
         ctsmtmibAttachmentInsertPolicy          INTEGER
         }

     ctsmtmibAttachmentSMTIndex  OBJECT-TYPE
         SYNTAX  INTEGER (1..65535)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The value of the SMT index associated with this
                  Attachment."
         ::= { ctsmtmibAttachmentEntry 1 }

     ctsmtmibAttachmentIndex  OBJECT-TYPE
         SYNTAX  INTEGER (1..65535)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "A unique value for each Attachment on a given SMT. "
         ::= { ctsmtmibAttachmentEntry 2 }

     ctsmtmibAttachmentClass  OBJECT-TYPE
         SYNTAX  INTEGER {
                     single-attachment(1),
                     dual-attachment(2),
                     concentrator(3)
                 }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The Attachment class. This represents a PORT or a pair
                  of PORTs plus the associated optional optical bypass
                  that are managed as a functional unit. The PORT
                  associations are the following unit.
                         single-attachment - S Ports
                         dual-attachment   - A/B Port pairs
                         concentrator      - M Ports
                 "
         ::= { ctsmtmibAttachmentEntry 3 }

     ctsmtmibAttachmentOpticalBypassPresent  OBJECT-TYPE
         SYNTAX  INTEGER {
                     true(1),
                     false(2)
                 }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "The value of this is false for 'single-attachment' .
                  Correct operation of CMT for single-attachments
                  requires that a bypass function must not loopback the
                  network side of the MIC, but only the node side."
         ::= { ctsmtmibAttachmentEntry 4 }

     ctsmtmibAttachmentIMaxExpiration  OBJECT-TYPE
         SYNTAX  INTEGER (0..2147483647)
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "I_Max (refer to ANSI SMT 9.4.4.2.1). Systems not
                  implementing optical bypass should return a value of
                  0. Else the value should be returned in the granularity
                  of 80ns."
         ::= { ctsmtmibAttachmentEntry 5 }

     ctsmtmibAttachmentInsertedStatus  OBJECT-TYPE
         SYNTAX  INTEGER {
                     true(1),
                     false(2),
                     unimplemented(3)
                 }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
                 "Indicates whether the attachment is currently inserted
                  in the node."
         ::= { ctsmtmibAttachmentEntry 6 }

     ctsmtmibAttachmentInsertPolicy  OBJECT-TYPE
         SYNTAX  INTEGER {
                     true(1),
                     false(2),
                     unimplemented(3)
                 }
         ACCESS  read-write
         STATUS  mandatory
         DESCRIPTION
                 "Indicates the Insert Policy for this Attachment."
         ::= { ctsmtmibAttachmentEntry 7 }

ctsmtmibSMTTable OBJECT-TYPE
        SYNTAX SEQUENCE OF CtsmtmibSMTEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "Describes the dual homed status for SMT entries."
        ::= { ctsmtmib 5 }

ctsmtmibSMTEntry OBJECT-TYPE
        SYNTAX CtsmtmibSMTEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A specific dual homed SMT entry."
        INDEX { ctsmtmibSmtIndex }
        ::= { ctsmtmibSMTTable 1 }

CtsmtmibSMTEntry ::= SEQUENCE {
        ctsmtmibSMTDualHomeStatus
                INTEGER,
        ctsmtmibSMTDualHomeWrpLEDStatus
                INTEGER,
        ctsmtmibSmtIndex
                INTEGER
}


ctsmtmibSMTDualHomeStatus       OBJECT-TYPE
        SYNTAX  INTEGER {
                notDualHomed(1),
                linkAorB(2),
                linkAandB(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Indicates the current dual homed link status for a given
                SMT instance.
                        notDualHomed(1) - This SMT is not dual homed.
                        linkAorB(2) - Dual homed with link on A and no link
                                      link on B, or link on B and no link
                                      on A.
                        linkAandB(3) - Dual homed with link on A and B."
        ::= { ctsmtmibSMTEntry 1}


ctsmtmibSMTDualHomeWrpLEDStatus OBJECT-TYPE
        SYNTAX INTEGER {
                on(1),
                off(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "When on, the WRAP LED will be illuminated when
                the node is in a dual homed configuration with link on the
                A, B or both A and B ports. When off, the WRAP LED will not
                be illuminated when the node is in a dual homed
                configuration with link on A and B, but will be illuminated
                when in a dual homed configuration with no link on A or B."
        DEFVAL { on }
        ::= { ctsmtmibSMTEntry 2}

ctsmtmibSmtIndex        OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Specifies the particular SMT entry."
        ::= { ctsmtmibSMTEntry 3 }