ENTERASYS-ESWITCH-MIB device MIB details by Enterasys Networks
ENTERASYS-ESWITCH-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ENTERASYS-ESWITCH-MIB.
Vendor: | Enterasys Networks |
---|---|
Mib: | ENTERASYS-ESWITCH-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
ENTERASYS-ESWITCH-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF EnabledStatus FROM P-BRIDGE-MIB PortList FROM Q-BRIDGE-MIB ifIndex FROM IF-MIB etsysModules FROM ENTERASYS-MIB-NAMES; enterasysESwitchMIB MODULE-IDENTITY LAST-UPDATED "200203071950Z" -- Thu Mar 7 19:50 GMT 2002 ORGANIZATION "Enterasys Networks, Inc" CONTACT-INFO "Postal: Enterasys Networks 35 Industrial Way, P.O. Box 5005 Rochester, NH 03867-0505 Phone: +1-603-332-9400 E-Mail: support@enterasys.com WWW: http://www.enterasys.com" DESCRIPTION "The Enterasys Networks Proprietary MIB module for entities implementing the Extended Switch Objects." REVISION "200203071950Z" -- Thu Mar 7 19:50 GMT 2002 DESCRIPTION "Imported etsysModules from the correct MIB." REVISION "200102131100Z" DESCRIPTION "The initial version of this MIB module." ::= { etsysModules 10 } -- ---------------------------------------------------------------------------- -- Textual Conventions (i.e., these do not affect object encoding): -- ---------------------------------------------------------------------------- -- -- "DURABLE": -- Objects that are saved across a system reset and/or power cycle -- are noted as "DURABLE" for convenience in the DESCRIPTION -- section of the object definition. Code must be explicitly -- written to implement these DURABLE objects. -- -- "PERSISTENT": -- This keyword is used to define persistent NVM+ objects (i.e., -- object values that survive a system "reset to factory -- defaults"). -- -- ---------------------------------------------------------------------------- -- Enterasys Extended Switch MIB-OIDs for Access Point. -- ---------------------------------------------------------------------------- etsysESwitchObjects OBJECT IDENTIFIER ::= { enterasysESwitchMIB 1 } -- **************************************************************************** etsysESwitchParams OBJECT IDENTIFIER ::= { etsysESwitchObjects 1 } etsysESwitchRateLimiting OBJECT IDENTIFIER ::= { etsysESwitchObjects 2 } etsysESwitchFilter OBJECT IDENTIFIER ::= { etsysESwitchObjects 3 } etsysESwitchProtocolObjects OBJECT IDENTIFIER ::= { etsysESwitchObjects 4 } -- **************************************************************************** -- -- etsysESwitchParams - The Extended system module -- This group consists of objects that detremine the state of -- the Access Piont. -- etsysESwitchAdminStatus OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: The meanings of the values are: enabled(1) - setting this object to enabled causes the device to begin it's power up sequence and attempt to enter its operational state. If the value of this object was disabled, then the non-volatile value of this object is changed to enabled. As part of the power up sequence, the device's management parameters may or may not be reset. (In other words, the device may go through the equivalent of a reset or before returning to the online state. If the device is capable of going directly from the disabled state to the enabled state without resetting any of its management parameters, then it may do so. Such action is product specific.) disabled(2) - setting this object to offline causes the device to cease network activity and enter a quiescent state. A disabled device must still be able to respond to management messages. The value enable(1) or disable(2) shall be stored in non-volatile memory for the initial reset value of this variable. The factory default NV value is enable(1)." ::= { etsysESwitchParams 1 } -- **************************************************************************** etsysESwitchRateLimitingTable OBJECT-TYPE SYNTAX SEQUENCE OF EtsysESwitchRateLimitingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table allows rate limiting of multicast frames received on bridge ports. A typical application of this might be to limit a broadcast storm to the confines of the LAN connected by the bridge. All objects in this table must be saved across a system reset and/or a power cycle." ::= { etsysESwitchRateLimiting 1 } etsysESwitchRateLimitingEntry OBJECT-TYPE SYNTAX EtsysESwitchRateLimitingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the RateLimiting Table. A collection of objects containing information for enabling and configuring RateLimiting." INDEX {ifIndex} ::= { etsysESwitchRateLimitingTable 1 } EtsysESwitchRateLimitingEntry ::= SEQUENCE { etsysESwitchRateLimitSwitch TruthValue, etsysESwitchRateLimit Unsigned32 } etsysESwitchRateLimitSwitch OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: By default, rate limiting will be disabled. It can be enabled by setting this object to 'true(1)'." ::= { etsysESwitchRateLimitingEntry 1 } etsysESwitchRateLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: This is the maximum number of rate-limited frames per second that the bridge will forward per second." ::= { etsysESwitchRateLimitingEntry 2 } -- *********************************************************************** -- -- etsysESwitchFilter - The Extended Switch Filter group -- These are bridge objects implemented in Enterasys Extended Switch -- over and above what is required by the Standard Bridge MIBs -- -- etsysESwitchFilter - per-port address filtering switches -- for multiport switch etsysESwitchAddrFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF EtsysESwitchAddrFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of interface entries. The number of entries is given by ifNumber, defined in MIB-II." ::= { etsysESwitchFilter 1 } etsysESwitchAddrFilterEntry OBJECT-TYPE SYNTAX EtsysESwitchAddrFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects containing information for a given interface." INDEX { ifIndex } ::= { etsysESwitchAddrFilterTable 1 } EtsysESwitchAddrFilterEntry ::= SEQUENCE { etsysESwitchAddressFilter TruthValue } etsysESwitchAddressFilter OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "DURABLE: A switch that controls address filtering. When true, the bridge purges the learned entries from its forwarding database, stops its learning process, and forwards only frames with destination and source addresses that have been specified via management." ::= { etsysESwitchAddrFilterEntry 1 } -- *********************************************************************** -- ------------------------------------------------------------------------- -- User-defined EtherType table -- ------------------------------------------------------------------------- etsysESwitchEtherTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF EtsysESwitchEtherTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table for defining the meaning of the 'userEtherType' rows in the etsysESwitchProtocolTable." ::= { etsysESwitchProtocolObjects 1 } etsysESwitchEtherTypeEntry OBJECT-TYPE SYNTAX EtsysESwitchEtherTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row defines a particular EtherType that may be used as a basis for protocol filtering and VLAN classification." INDEX { etsysESwitchEtherTypeIndex } ::= { etsysESwitchEtherTypeTable 1 } EtsysESwitchEtherTypeEntry ::= SEQUENCE { etsysESwitchEtherTypeIndex INTEGER, etsysESwitchEtherTypeValue OCTET STRING, etsysESwitchEtherTypeStatus INTEGER, etsysESwitchEtherTypePreempted TruthValue } etsysESwitchEtherTypeIndex OBJECT-TYPE SYNTAX INTEGER( 1..1000 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and N that identifies a table row, and that serves to link entries in this table to those in etsysESwitchProtocolTable." ::= { etsysESwitchEtherTypeEntry 1 } etsysESwitchEtherTypeValue OBJECT-TYPE SYNTAX OCTET STRING( SIZE(2) ) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines an EtherType for use with etsysESwitchESwitchProtocolTable." ::= { etsysESwitchEtherTypeEntry 2 } etsysESwitchEtherTypeStatus OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), permanent(3), deleteOnReset(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the administrative status of this entry. other(1) - This entry is currently in effect, but the conditions under which it will remain so differ from the ones described for the other enumeration values invalid(2) - Writing this value invalidates the entry. The agent may (but is not required to) delete the row. permanent(3) - This entry is currently in use and will remain so after the next reset of the bridge. deleteOnReset(4) - This entry is currently in use and will remain so until the next reset of the bridge." DEFVAL { permanent } ::= { etsysESwitchEtherTypeEntry 3 } etsysESwitchEtherTypePreempted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If true, indicates that the switch has taken control of this row and its associated resources (e.g., to support 802.1x authentication)." ::= { etsysESwitchEtherTypeEntry 4 } -- ------------------------------------------------------------------------- -- Protocol-based filtering/VLAN table -- ------------------------------------------------------------------------- etsysESwitchProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF EtsysESwitchProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table for configuring, and obtaining information about, protocol- based filtering and VLAN assignment." ::= { etsysESwitchProtocolObjects 2 } etsysESwitchProtocolEntry OBJECT-TYPE SYNTAX EtsysESwitchProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row in etsysESwitchProtocolTable holds filtering instructions, or VLAN classification instructions, for one (port, protocol) pair." INDEX { etsysESwitchProtocolReceivePort, etsysESwitchProtocolType, etsysESwitchProtocolIndex } ::= { etsysESwitchProtocolTable 1 } EtsysESwitchProtocolEntry ::= SEQUENCE { etsysESwitchProtocolReceivePort INTEGER, etsysESwitchProtocolType INTEGER, etsysESwitchProtocolIndex INTEGER, etsysESwitchProtocolConstraint INTEGER, etsysESwitchProtocolAllowedToGoTo PortList, etsysESwitchProtocolVlanId INTEGER, etsysESwitchProtocolStatus INTEGER, etsysESwitchProtocolPreempted TruthValue } etsysESwitchProtocolReceivePort OBJECT-TYPE SYNTAX INTEGER ( 0..2147483647 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the receive port to which the protocol filter is to be applied. The value '0' (when allowed) represents 'all ports'." ::= { etsysESwitchProtocolEntry 1 } etsysESwitchProtocolType OBJECT-TYPE SYNTAX INTEGER { userEtherType(1), ipv4(2), ipxEthernet(3), ipxRaw(4), ipxLlc(5), ipxSnap(6), sna(7), netBios(8), decnet(9), ipv6(10) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the protocol type. The switch chip in the RoamAbout M2 can recognize nine predefined high-level protocol types, and up to three user-defined EtherTypes. (Some or all EtherType filters may be reserved for use in implementing other features.) Protocol types are as follows: userEtherType(1) - Packets whose Ethernet V2 EtherTypes or IEEE 802.3 LLC/SNAP EtherTypes match the user-defined EtherType etsysESwitchEtherType[ etsysESwitchProtocolIndex ]. ipv4(2) - Internet Protocol version 4 carried in Ethernet V2 frames or IEEE 802.3 frames with LLC/SNAP headers. Also, ARP packets carried in Ethernet V2 frames. ipxEthernet(3) - IPX carried in Ethernet V2 frames. ipxRaw(4) - IPX carried in IEEE 802.3 frames with no LLC. ipxLlc(5) - IPX carried in IEEE 802.3 frames with LLC headers. ipxSnap(6) - IPX carried in IEEE 802.3 frames with LLC/SNAP headers. sna(7) - SNA carried in IEEE 802.3 frames with LLC headers. netBios(8) - NetBIOS carried in IEEE 802.3 frames with LLC headers. decnet(9) - DECnet carried in Ethernet V2 frames or in IEEE 802.3 frames with LLC/SNAP headers. ipv6(10) - Internet Protocol version 6 carried in Ethernet V2 frames or IEEE 802.3 frames with LLC/SNAP headers" ::= { etsysESwitchProtocolEntry 2 } etsysESwitchProtocolIndex OBJECT-TYPE SYNTAX INTEGER ( 1..1000 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "When etsysESwitchProtocolType indicates a user-defined protocol type, this index should identify the corresponding protocol definition. That is, to say, for a 'userEtherType' row, this index should point to a row in the etsysESwitchEtherTypeTable. When etsysESwitchProtocolType completely specifies the protocol type, this index should be set to 1." ::= { etsysESwitchProtocolEntry 3 } etsysESwitchProtocolConstraint OBJECT-TYPE SYNTAX INTEGER { portMask(1), vlan(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates what type of constraint the switch should apply to packets caught by the (port, protocol) filter. portMask(1) - Use the etsysESwitchProtocolAllowedToGoTo mask to determine where the packets may be forwarded. vlan(2) - Classify the packets as belonging to the VLAN etsysESwitchProtocolVlanId. Note that on the RoamAbout AccessPoint R2, port/protocol constraints can sometimes take a back seat to other kinds of access controls." DEFVAL { portMask } ::= { etsysESwitchProtocolEntry 4 } etsysESwitchProtocolAllowedToGoTo OBJECT-TYPE SYNTAX PortList MAX-ACCESS read-create STATUS current DESCRIPTION "A port mask object indicating where packets that match this row's (port, protocol) filter are allowed to go. It applies when etsysESwitchProtocolConstraint has the value portMask(1) and this row is valid." ::= { etsysESwitchProtocolEntry 5 } etsysESwitchProtocolVlanId OBJECT-TYPE SYNTAX INTEGER ( 0..2147483647 ) MAX-ACCESS read-create STATUS current DESCRIPTION "A number identifying a VLAN to which packets that match this row's (port, protocol) filter should be assigned. It applies when etsysESwitchProtocolConstraint has the value vlan(2) and this row is valid." ::= { etsysESwitchProtocolEntry 6 } etsysESwitchProtocolStatus OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), permanent(3), deleteOnReset(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the administrative status of this entry. other(1) - This entry is currently in effect, but the conditions under which it will remain so differ from the ones described for the other enumeration values invalid(2) - Writing this value to the object deletes the filter or VLAN constraint. The agent may delete the SNMP table row or return an AdminStatus of 'invalid' at its discretion. permanent(3) - This entry is currently in use and will remain so after the next reset of the bridge. deleteOnReset(4) - This entry is currently in use and will remain so until the next reset of the bridge." DEFVAL { permanent } ::= { etsysESwitchProtocolEntry 7 } etsysESwitchProtocolPreempted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If true, indicates that the switch has taken control of this row and its associated resources (e.g., to support 802.1x authentication)." ::= { etsysESwitchProtocolEntry 8 } -- ---------------------------------------------------------------------------- -- Conformance Information -- ---------------------------------------------------------------------------- etsysESwitchConformance OBJECT IDENTIFIER ::= { enterasysESwitchMIB 2 } etsysESwitchGroups OBJECT IDENTIFIER ::= { etsysESwitchConformance 1 } etsysESwitchCompliances OBJECT IDENTIFIER ::= { etsysESwitchConformance 2 } -- ---------------------------------------------------------------------------- -- Units of conformance -- ---------------------------------------------------------------------------- etsysESwitchBaseGroup OBJECT-GROUP OBJECTS { etsysESwitchAdminStatus, etsysESwitchRateLimitSwitch, etsysESwitchRateLimit, etsysESwitchAddressFilter } STATUS current DESCRIPTION "The basic etsysESwitch objects." ::= { etsysESwitchGroups 1 } etsysESwitchEtherTypeGroup OBJECT-GROUP OBJECTS { etsysESwitchEtherTypeValue, etsysESwitchEtherTypeStatus, etsysESwitchEtherTypePreempted } STATUS current DESCRIPTION "A collection of objects for configuring user-defined EtherTypes." ::= { etsysESwitchGroups 2 } etsysESwitchProtocolGroup OBJECT-GROUP OBJECTS { etsysESwitchProtocolConstraint, etsysESwitchProtocolAllowedToGoTo, etsysESwitchProtocolVlanId, etsysESwitchProtocolStatus, etsysESwitchProtocolPreempted } STATUS current DESCRIPTION "A collection of objects for configuring protocol-based filtering." ::= { etsysESwitchGroups 3 } -- ---------------------------------------------------------------------------- -- Compliance statements -- ---------------------------------------------------------------------------- etsysESwitchCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices that support Extended Switch." MODULE ENTERASYS-ESWITCH-MIB MANDATORY-GROUPS { etsysESwitchBaseGroup } GROUP etsysESwitchEtherTypeGroup DESCRIPTION "This group is optional." GROUP etsysESwitchProtocolGroup DESCRIPTION "This group is optional." OBJECT etsysESwitchEtherTypeValue MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT etsysESwitchEtherTypeStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation does not need to support all possible status types." OBJECT etsysESwitchProtocolConstraint MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation does not need to support all possible constraint types." OBJECT etsysESwitchProtocolAllowedToGoTo MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT etsysESwitchProtocolVlanId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT etsysESwitchProtocolStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required. An implementation does not need to support all possible status types." ::= { etsysESwitchCompliances 1 } END