AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys Networks » ENTERASYS-MSTP-MIB

ENTERASYS-MSTP-MIB device MIB details by Enterasys Networks

ENTERASYS-MSTP-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ENTERASYS-MSTP-MIB.


Vendor: Enterasys Networks
Mib: ENTERASYS-MSTP-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
ENTERASYS-MSTP-MIB DEFINITIONS ::= BEGIN

--  enterasys-mstp-mib.txt
--
--  Part Number:
--
--

--  This module provides authoritative definitions for Enterasys 
--  Networks' implementation of the Multiple Spanning Tree Protocol
--  defined by IEEE 802.1s.

--
--  This module will be extended, as needed.

--  Enterasys Networks reserves the right to make changes in this
--  specification and other information contained in this document
--  without prior notice.  The reader should consult Enterasys Networks
--  to determine whether any such changes have been made.
--
--  In no event shall Enterasys Networks be liable for any incidental,
--  indirect, special, or consequential damages whatsoever (including
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Enterasys
--  Networks has been advised of, known, or should have known, the
--  possibility of such damages.
--
--  Enterasys Networks grants vendors, end-users, and other interested
--  parties a non-exclusive license to use this Specification in 
--  connection with the management of Enterasys Networks products.

--  Copyright September, 2002-2004 Enterasys Networks, Inc.

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32, TimeTicks
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, RowStatus, TruthValue
        FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    InterfaceIndex
        FROM IF-MIB
    EnabledStatus
        FROM P-BRIDGE-MIB
    BridgeId
        FROM BRIDGE-MIB
    etsysModules
        FROM ENTERASYS-MIB-NAMES;

etsysMstpMIB MODULE-IDENTITY
    LAST-UPDATED "200402122138Z"  -- Thu Feb 12 21:38 GMT 2004
    ORGANIZATION "Enterasys Networks, Inc"
    CONTACT-INFO
    "Postal: Enterasys Networks
             35 Industrial Way, P.O. Box 5005
             Rochester, NH 03867-0505

     Phone:  +1 603 332 9400
     E-mail: support@enterasys.com
     WWW:    http://www.enterasys.com"
    DESCRIPTION
        "This mib module defines a portion of the SNMP enterprise
         MIBs under Enterasys Networks' enterprise OID pertaining to 
         the Multiple Spanning Tree Protocol defined by IEEE 802.1s.

         This MIB is used to manage devices which support MSTP.  
         It will be supported until a standard IEEE 802.1s MIB has 
         been defined by the IETF."

    REVISION "200402122138Z"  -- Thu Feb 12 21:38 GMT 2004
    DESCRIPTION
        "Added etsysMstpAutoEdgeDetection and
         etsysMstpBridgeHelloTimeMode objects."

    REVISION "200301211427Z"  -- Tue Jan 21 14:27 GMT 2003
    DESCRIPTION
        "Changed syntax of etsysMstpConfigDigest object from
         SnmpAdminString to HexString.
         Added applicable range limitations and default values to
         read-write objects.
         Enhanced various object descriptions for clarity."

    REVISION "200210111705Z"  -- Fri Oct 11 17:05 GMT 2002
    DESCRIPTION
        "The initial version of this MIB module."

    ::= { etsysModules 28 } 

etsysMstpObjects      OBJECT IDENTIFIER ::= { etsysMstpMIB 1 }


-- ---------------------------------------------------------- --
-- Textual Conventions
-- ---------------------------------------------------------- --

HexString  ::=  TEXTUAL-CONVENTION
    DISPLAY-HINT "1x:"
    STATUS       current
    DESCRIPTION
        "An OCTET-STRING with a suitable display hint."
    SYNTAX       OCTET STRING (SIZE (0..1024))


-- ---------------------------------------------------------- --
-- branches in the ENTERASYS-MSTP MIB
-- ---------------------------------------------------------- --

etsysMstpConfig  OBJECT IDENTIFIER ::= { etsysMstpObjects 1 }
etsysMstpBridge  OBJECT IDENTIFIER ::= { etsysMstpObjects 2 }
etsysMstpPort    OBJECT IDENTIFIER ::= { etsysMstpObjects 3 }
etsysMstpExtn    OBJECT IDENTIFIER ::= { etsysMstpObjects 4 }


-- ---------------------------------------------------------- --
-- the MST Configuration group
-- ---------------------------------------------------------- --

etsysMstpMaxMstId  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "The maximum Multiple Spanning Tree (MST) instance ID 
       that this device supports." 
    REFERENCE
      "IEEE 802.1s clause 12.8.1.2.2"
    DEFVAL { 4094 }
    ::= { etsysMstpConfig 1 }

etsysMstpMaxSupportedMsts  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "The maximum number of Multiple Spanning Tree
       instances that this device supports."
    REFERENCE
      "IEEE 802.1s clause 5.1 item j"
    DEFVAL { 64 }
    ::= { etsysMstpConfig 2 }

etsysMstpNumMsts  OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "The current number of Multiple Spanning Tree
       instances that are configured in this device."
    REFERENCE
      "IEEE 802.1s clause 12.12.1"
    ::= { etsysMstpConfig 3 }

-- ---------------------------------------------------------- --
-- MSTI Table
-- ---------------------------------------------------------- --

etsysMstpMstiTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpMstiEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The list of configured Multiple Spanning Tree
       instances."
    REFERENCE
      "IEEE 802.1s clause 12.12.1"
    ::= { etsysMstpConfig 4 }

etsysMstpMstiEntry OBJECT-TYPE
    SYNTAX        EtsysMstpMstiEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table entry representing a Multiple Spanning Tree
       instance."
    INDEX { etsysMstpMstId }
    ::= { etsysMstpMstiTable 1 }

EtsysMstpMstiEntry ::=
    SEQUENCE { 
     etsysMstpMstId                      Unsigned32,
     etsysMstpMstiStatus                 RowStatus
    }

etsysMstpMstId OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The unique ID of this Multiple Spanning Tree instance.
       This value SHALL be between 1 and etsysMstpMaxMstId 
       inclusively."
    ::= { etsysMstpMstiEntry 1 }

etsysMstpMstiStatus OBJECT-TYPE
    SYNTAX        RowStatus
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
      "This object allows for the dynamic creation and
       deletion of the corresponding Spanning Tree instance.

       Creation and activation of a conceptual row in this
       table MUST be performed as a single operation -- by
       setting this object to createAndGo(4) -- and 
       suspension of an active conceptual row is not
       supported.  Consequently, setting this object to
       createAndWait(5) or notInService(2) SHALL fail.

       Setting this object to destroy(6) SHALL fail if the
       corresponding Spanning Tree instance has one or more
       FIDs allocated to it in the FID to MSTID Allocation
       Table (etsysMstpAllocTable).

       Refer to the RowStatus convention for further details on 
       the behavior of this object."
    REFERENCE
      "RFC2579 (Textual Conventions for SMIv2)"
    ::= { etsysMstpMstiEntry 2 }

-- ---------------------------------------------------------- --
-- FID to MSTID Allocation Table
-- ---------------------------------------------------------- --

etsysMstpAllocTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpAllocEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table that contains the mapping of Filtering
       Databases to Spanning Tree instances."
    REFERENCE
      "IEEE 802.1s clause 12.12.2"
    ::= { etsysMstpConfig 5 }

etsysMstpAllocEntry OBJECT-TYPE
    SYNTAX        EtsysMstpAllocEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The mapping of a particular Filtering Database to
       a Spanning Tree instance."
    INDEX { etsysMstpFdbId }
    ::= { etsysMstpAllocTable 1 }

EtsysMstpAllocEntry ::=
    SEQUENCE { 
     etsysMstpFdbId                      Unsigned32,
     etsysMstpMstIdOfFdb                 Unsigned32
    }

etsysMstpFdbId OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The unique ID of the Filtering Database to which the 
       information in this table entry applies.  This value 
       SHALL be between 1 and dot1qMaxVlanId inclusively."
    ::= { etsysMstpAllocEntry 1 }

etsysMstpMstIdOfFdb OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
      "The ID of the Spanning Tree instance to which the 
       corresponding FID is mapped.  This ID must either
       be 0 (i.e., the CIST) or be a value which is present
       in the MSTI Table (etsysMstpMstiTable)."
    DEFVAL { 0 }
    ::= { etsysMstpAllocEntry 2 }


-- ---------------------------------------------------------- --
-- MST Configuration Table
-- ---------------------------------------------------------- --

etsysMstpConfigTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpConfigEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table that contains the mapping of VLANs to
       Spanning Tree instances.  This table is a read-only
       table, its elements derived from the VID to FID
       allocation table and the FID to MSTID allocation
       table."
    REFERENCE
      "IEEE 802.1s clause 12.12.3"
    ::= { etsysMstpConfig 6 }

etsysMstpConfigEntry OBJECT-TYPE
    SYNTAX        EtsysMstpConfigEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The mapping of a particular VLAN to a Spanning Tree
       instance."
    INDEX { etsysMstpVlanId }
    ::= { etsysMstpConfigTable 1 }

EtsysMstpConfigEntry ::=
    SEQUENCE { 
     etsysMstpVlanId                     Unsigned32,
     etsysMstpMstIdOfVlan                Unsigned32
    }

etsysMstpVlanId OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The unique ID of the VLAN to which the information in 
       this table entry applies.  This value SHALL be between
       1 and dot1qMaxVlanId inclusively."
    ::= { etsysMstpConfigEntry 1 }

etsysMstpMstIdOfVlan OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The ID of the Spanning Tree instance to which the 
       corresponding VLAN is mapped."
    ::= { etsysMstpConfigEntry 2 }


-- ---------------------------------------------------------- --
-- MST Configuration Identifier
-- ---------------------------------------------------------- --

etsysMstpFormatSelector OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "The format selector value of the Configuration
       Identifier.  This has a value of 0 to indicate the
       format specified in the IEEE 802.1s standard."  
    REFERENCE
      "IEEE 802.1s clause 13.7"
    ::= { etsysMstpConfig 7 }

etsysMstpConfigName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..32))  
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
      "The configuration name of the MST region to which
       this bridge belongs.  The default value is the
       Bridge Address of this bridge, as a text string 
       using the Hexadecimal Representation defined in
       IEEE Std. 802."
    REFERENCE
      "IEEE 802.1s clause 13.7"
    ::= { etsysMstpConfig 8 }

etsysMstpRevisionLevel OBJECT-TYPE
    SYNTAX      Unsigned32 (0..65535) 
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
      "The revision level of the MST region to which
       this bridge belongs."  
    REFERENCE
      "IEEE 802.1s clause 13.7"
    DEFVAL { 0 }
    ::= { etsysMstpConfig 9 } 

etsysMstpConfigDigest OBJECT-TYPE
    SYNTAX      HexString (SIZE(16))  
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "The Configuration Digest derived from the MST
       Configuration Table."  
    REFERENCE
      "IEEE 802.1s clause 13.7"
    ::= { etsysMstpConfig 10 }


-- ---------------------------------------------------------- --
-- the MST Bridge group
-- ---------------------------------------------------------- --

etsysMstpCistRegionalRootIdentifier OBJECT-TYPE
    SYNTAX        BridgeId
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The Bridge Identifier of the current CIST Regional
       Root."
    ::= { etsysMstpBridge 1 }

etsysMstpCistPathCost OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The CIST path cost from this bridge to the CIST
       Regional Root."
    ::= { etsysMstpBridge 2 }

etsysMstpMaxHopCount OBJECT-TYPE
    SYNTAX      Unsigned32 (0..255)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
      "The maximum number of hops that the information for a
       particular Spanning Tree instance may traverse (via
       relay of BPDUs within the applicable MST region) before
       being discarded.  This value is used only if this bridge
       is the CIST Regional Root and/or the MSTI Regional Root
       for one or more Multiple Spanning Tree instances."
    DEFVAL { 20 }
    ::= { etsysMstpBridge 3 }


etsysMstpBridgeTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpBridgeEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table that contains bridge protocol parameter values
       associated with each configured Multiple Spanning Tree
       instance."
    ::= { etsysMstpBridge 4 }

etsysMstpBridgeEntry OBJECT-TYPE
    SYNTAX        EtsysMstpBridgeEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A list of information maintained by each Multiple
       Spanning Tree instance configured on this bridge."
    INDEX { etsysMstpMstId }
    ::= { etsysMstpBridgeTable 1 }

EtsysMstpBridgeEntry ::=
    SEQUENCE { 
     etsysMstpBridgePriority                  Unsigned32,
     etsysMstpTimeSinceTopologyChange         TimeTicks,
     etsysMstpTopologyChangeCount             Counter32,
     etsysMstpTopologyChangeInProgress        TruthValue,
     etsysMstpDesignatedRoot                  BridgeId,
     etsysMstpRootPathCost                    Unsigned32,
     etsysMstpRootPort                        Unsigned32
    }

etsysMstpBridgePriority OBJECT-TYPE
    SYNTAX        Unsigned32 (0..61440)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
      "The value of the priority component of the Bridge
       ID for the corresponding Spanning Tree instance.
       Specifically, the four most significant bits of the
       most significant octet of the (8 octet long) Bridge
       ID followed by 12 zero bits.  Note that this object
       may only be set to a 16-bit value in which the least
       significant 12 bits are zero, i.e., permissible values
       are 0-61440, in steps of 4096."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    DEFVAL { 32768 }
    ::= { etsysMstpBridgeEntry 1 }

etsysMstpTimeSinceTopologyChange OBJECT-TYPE
    SYNTAX        TimeTicks
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The elapsed time, in units of hundredths of a second,
       since the last time a topology change was detected by
       the corresponding Spanning Tree instance (specifically,
       the elapsed time since the tcWhile timer for any port
       was non-zero)."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 2 }

etsysMstpTopologyChangeCount OBJECT-TYPE
    SYNTAX        Counter32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The total number of topology changes detected by
       the corresponding Spanning Tree instance since the 
       management entity was last reset or initialized
       (specifically, the count of times that the tcWhile
       timer for any port has been non-zero)."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 3 }

etsysMstpTopologyChangeInProgress OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "True(1) if the tcWhile timer is non-zero for any port
       for the corresponding Spanning Tree instance, false(2)
       otherwise."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 4 }

etsysMstpDesignatedRoot OBJECT-TYPE
    SYNTAX        BridgeId
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The bridge identifier of the root for the corresponding
       Spanning Tree instance."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 5 }

etsysMstpRootPathCost OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The cost of the path to the root of the corresponding
       Spanning Tree instance as seen from this bridge."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 6 }

etsysMstpRootPort OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The port number of the port which offers the
       lowest cost path from this bridge to the root
       bridge for the corresponding Spanning Tree instance."
    REFERENCE
      "IEEE 802.1s clause 12.8.1"
    ::= { etsysMstpBridgeEntry 7 }


-- ---------------------------------------------------------- --
-- the MST Port group
-- ---------------------------------------------------------- --

etsysMstpPortTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpPortEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table that contains port parameter values for
       each configured Multiple Spanning Tree instance."
    ::= { etsysMstpPort 1 }

etsysMstpPortEntry OBJECT-TYPE
    SYNTAX        EtsysMstpPortEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A list of information maintained for every port
       by each Multiple Spanning Tree instance configured
       on this bridge."     
    INDEX { etsysMstpMstId, etsysMstpPortNumber }
    ::= { etsysMstpPortTable 1 }

EtsysMstpPortEntry ::=
    SEQUENCE { 
     etsysMstpPortNumber                      InterfaceIndex,
     etsysMstpPortPriority                    Unsigned32,
     etsysMstpPortState                       INTEGER,
     etsysMstpPortAdminPathCost               Unsigned32,
     etsysMstpPortOperPathCost                Unsigned32,
     etsysMstpPortDesignatedRoot              BridgeId,
     etsysMstpPortDesignatedCost              Unsigned32,
     etsysMstpPortDesignatedBridge            BridgeId,
     etsysMstpPortDesignatedPort              OCTET STRING,
     etsysMstpPortRoleValue                   INTEGER
    }

etsysMstpPortNumber OBJECT-TYPE
    SYNTAX        InterfaceIndex
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "The port number of the port for which this entry
       contains Multiple Spanning Tree Protocol management
       information."
    ::= { etsysMstpPortEntry 1 }

etsysMstpPortPriority OBJECT-TYPE
    SYNTAX        Unsigned32 (0..240)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
      "The value of the priority field which is contained in
       the first (in network byte order) octet of the (2 octet
       long) Port ID for the corresponding Spanning Tree
       instance.  Permissible values are 0-240, in steps of 16."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    DEFVAL { 128 }
    ::= { etsysMstpPortEntry 2 }

etsysMstpPortState OBJECT-TYPE
    SYNTAX        INTEGER {
                      disabled(1),
                      blocking(2),
                      listening(3),
                      learning(4),
                      forwarding(5),
                      broken(6)
                  }
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The port's current state in the corresponding Spanning
       Tree instance as defined by application of the Multiple
       Spanning Tree Protocol.  This state controls what action
       a port takes on reception of a frame.  If the bridge has
       detected a port that is malfunctioning it will place that
       port into the broken(6) state.  For ports which are
       administratively disabled (see dot1dStpPortEnable), this
       object will have a value of disabled(1)."
    ::= { etsysMstpPortEntry 3 }

etsysMstpPortAdminPathCost OBJECT-TYPE
    SYNTAX        Unsigned32 (0..200000000)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
      "The administratively assigned value for the contribution
       of this port to the path cost of paths towards the root
       of the corresponding Spanning Tree instance.

       Writing a value of '0' assigns the automatically calculated
       default Path Cost value to the port for this instance.  If
       the default Path Cost is being used, this object returns
       '0' when read.

       This complements the object etsysMstpPortOperPathCost,
       which returns the operational value of the path cost."
    REFERENCE
      "IEEE 802.1s clause 12.8.2, IEEE 802.1t-2001 Table 8-5"
    DEFVAL { 0 }
    ::= { etsysMstpPortEntry 4 }

etsysMstpPortOperPathCost OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The operational value for the contribution of this port to
       the path cost of paths towards the root of the corresponding
       Spanning Tree instance."
    REFERENCE
      "IEEE 802.1s clause 12.8.2, IEEE 802.1t-2001 Table 8-5"
    ::= { etsysMstpPortEntry 5 }

etsysMstpPortDesignatedRoot OBJECT-TYPE
    SYNTAX        BridgeId
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The unique Bridge Identifier of the Bridge recorded
       as the Root of the corresponding Spanning Tree in the
       Configuration BPDUs transmitted by the Designated
       Bridge for the segment to which the port is attached."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    ::= { etsysMstpPortEntry 6 }

etsysMstpPortDesignatedCost OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The path cost of the Designated Port of the segment
       connected to this port, for the corresponding
       Spanning Tree instance.  This value is compared to
       the Root Path Cost field in received bridge PDUs."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    ::= { etsysMstpPortEntry 7 }

etsysMstpPortDesignatedBridge OBJECT-TYPE
    SYNTAX        BridgeId
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The Bridge Identifier of the bridge which this
       port considers to be the Designated Bridge for
       this port's segment on the corresponding Spanning
       Tree instance."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    ::= { etsysMstpPortEntry 8 }

etsysMstpPortDesignatedPort OBJECT-TYPE
    SYNTAX        OCTET STRING
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The Port Identifier of the port on the Designated
       Bridge for this port's segment on the corresponding
       Spanning Tree instance."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    ::= { etsysMstpPortEntry 9 }

etsysMstpPortRoleValue OBJECT-TYPE
    SYNTAX      INTEGER {
                         disabled(1), 
                         root(2),
                         designated(3),
                         alternate(4),
                         backUp(5),
                         master(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
      "Indicates this port's role on the corresponding
       Spanning Tree instance.

       disabled --  this port has no role on this MST instance. 

       root -- this port has the role of root port on this MST
                   instance. 

       designated -- this port has the role of designated 
                   port on this MST instance.

       alternate -- this port has the role of alternate port
                   on this MST instance.

       backUp -- this port has the role of backup port on this  
                   MST instance.

       master -- this port has the role of master port on 
                   this MST instance." 
    ::= { etsysMstpPortEntry 10 }


etsysMstpGlobalPortTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF EtsysMstpGlobalPortEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A table that contains port parameter values which
       apply to all Spanning Tree instances."
    ::= { etsysMstpPort 2 }

etsysMstpGlobalPortEntry OBJECT-TYPE
    SYNTAX        EtsysMstpGlobalPortEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
      "A list of information maintained for every port
       which applies to all Spanning Tree instances."
    INDEX { etsysMstpPortNumber }
    ::= { etsysMstpGlobalPortTable 1 }

EtsysMstpGlobalPortEntry ::=
    SEQUENCE { 
     etsysMstpHelloTime                       Unsigned32,
     etsysMstpPortHelloTime                   Unsigned32,
     etsysMstpBoundaryPort                    TruthValue
    }

etsysMstpHelloTime OBJECT-TYPE
    SYNTAX        Unsigned32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "The amount of time, in hundredths of a second, between
       the transmission of Configuration bridge PDUs on this
       port when it has the role of designated port for any
       Spanning Tree instance.  This is the actual value that
       this bridge is currently using."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    ::= { etsysMstpGlobalPortEntry 1 }

etsysMstpPortHelloTime OBJECT-TYPE
    SYNTAX        Unsigned32 (100..1000)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
      "The value, in hundredths of a second, that all bridges
       attached to this port's LAN segment use for HelloTime
       when this bridge is acting as the CIST root."
    REFERENCE
      "IEEE 802.1s clause 12.8.2"
    DEFVAL { 200 }
    ::= { etsysMstpGlobalPortEntry 2 }

etsysMstpBoundaryPort OBJECT-TYPE
    SYNTAX        TruthValue
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
      "True(1) if this port is attached to a LAN which is in
       a different MST Region than this bridge, false(2)
       otherwise."
    ::= { etsysMstpGlobalPortEntry 3 }

-- ---------------------------------------------------------- --
-- the MST Extension group
-- ---------------------------------------------------------- --

etsysMstpAutoEdgeDetection OBJECT-TYPE
    SYNTAX      EnabledStatus
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The enabled/disabled status of automatic edge detection."
    REFERENCE
        "IEEE 802.1D-D4 Section 17.25."
    DEFVAL { enabled }
    ::= { etsysMstpExtn 1 }

etsysMstpBridgeHelloTimeMode OBJECT-TYPE
    SYNTAX      EnabledStatus
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "The enabled/disabled status of the legacy bridge hello
         mode of operation.  When enabled, and this bridge is
         acting as the root bridge, dot1dStpBridgeHelloTime
         is used.  When disabled, and this bridge is acting as
         the root bridge, etsysMstpPortHelloTime is used."
    REFERENCE
        "IEEE 802.1s-2002 Section 13.22(e) and 12.8.2.1.3(s)."
    DEFVAL { enabled }
    ::= { etsysMstpExtn 2 }

-- -------------------------------------------------------------
-- Conformance Information
-- -------------------------------------------------------------

etsysMstpConformance OBJECT IDENTIFIER ::= { etsysMstpMIB 2 }

etsysMstpGroups      OBJECT IDENTIFIER ::= { etsysMstpConformance 1 }
etsysMstpCompliances OBJECT IDENTIFIER ::= { etsysMstpConformance 2 }

-- -------------------------------------------------------------
-- Units of conformance
-- -------------------------------------------------------------

etsysMstpConfigGroup OBJECT-GROUP
    OBJECTS {
        etsysMstpMaxMstId,
        etsysMstpMaxSupportedMsts,
        etsysMstpNumMsts,
        etsysMstpMstiStatus,
        etsysMstpMstIdOfFdb,
        etsysMstpMstIdOfVlan,
        etsysMstpFormatSelector,
        etsysMstpConfigName,
        etsysMstpRevisionLevel,
        etsysMstpConfigDigest
    }
    STATUS      current
    DESCRIPTION
      "A collection of objects providing configuration support
       for the Multiple Spanning Tree Protocol."
    ::= { etsysMstpGroups 1 }

etsysMstpBridgeGroup OBJECT-GROUP
    OBJECTS {
        etsysMstpCistRegionalRootIdentifier,
        etsysMstpCistPathCost,
        etsysMstpMaxHopCount,
        etsysMstpBridgePriority,
        etsysMstpTimeSinceTopologyChange,
        etsysMstpTopologyChangeCount,
        etsysMstpTopologyChangeInProgress,
        etsysMstpDesignatedRoot,
        etsysMstpRootPathCost,
        etsysMstpRootPort
    }
    STATUS      current
    DESCRIPTION
      "A collection of objects providing bridge-level support
       for the Multiple Spanning Tree Protocol."
    ::= { etsysMstpGroups 2 }

etsysMstpPortGroup OBJECT-GROUP
    OBJECTS {
        etsysMstpPortPriority,
        etsysMstpPortState,
        etsysMstpPortAdminPathCost,
        etsysMstpPortOperPathCost,
        etsysMstpPortDesignatedRoot,
        etsysMstpPortDesignatedCost,
        etsysMstpPortDesignatedBridge,
        etsysMstpPortDesignatedPort,
        etsysMstpPortRoleValue,
        etsysMstpHelloTime,
        etsysMstpPortHelloTime,
        etsysMstpBoundaryPort
    }
    STATUS      current
    DESCRIPTION
      "A collection of objects providing port-level support
       for the Multiple Spanning Tree Protocol."
    ::= { etsysMstpGroups 3 }

etsysMstpAutoEdgeDetectGroup OBJECT-GROUP
    OBJECTS {
        etsysMstpAutoEdgeDetection
    }
    STATUS      current
    DESCRIPTION
      "An object for controlling Auto Edge Detection."
    ::= { etsysMstpGroups 4 }

etsysMstpBridgeHelloTimeGroup OBJECT-GROUP
    OBJECTS {
        etsysMstpBridgeHelloTimeMode
    }
    STATUS      current
    DESCRIPTION
      "An object for modifying the Hello Time mode."
    ::= { etsysMstpGroups 5 }


-- -------------------------------------------------------------
-- Compliance statements
-- -------------------------------------------------------------

etsysMstpCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
      "The compliance statement for devices that support the
       Multiple Spanning Tree Protocol."

    MODULE
        MANDATORY-GROUPS {
            etsysMstpConfigGroup,
            etsysMstpBridgeGroup,
            etsysMstpPortGroup
        }

        GROUP       etsysMstpAutoEdgeDetectGroup
        DESCRIPTION
            "Support for this group is optional and only applies
             to products that support auto edge detection."

        GROUP       etsysMstpBridgeHelloTimeGroup
        DESCRIPTION
            "Support for this group is optional and only applies
             to products that support for multiple hello time modes."

    ::= { etsysMstpCompliances 1 }