AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » NEC Corporation » A100-R1-MIB

A100-R1-MIB device MIB details by NEC Corporation

A100-R1-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing A100-R1-MIB.


Vendor: NEC Corporation
Mib: A100-R1-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
--
-- Copyright (c) 1994 by cisco Systems, Inc.
-- All rights reserved.
--
--------------------------------------------------------------------

A100-R1-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        enterprises                FROM RFC1155-SMI
        OBJECT-TYPE                FROM RFC-1212
        DisplayString              FROM RFC1213-MIB;

-- ciscoA100Mib MODULE-IDENTITY
--         LAST-UPDATED    "9411170000Z"
--         ORGANIZATION    "Cisco Systems, Inc."
--         CONTACT-INFO
--                 "       Cisco Systems
--                         Customer Service
-- 
--                 Postal: 170 W Tasman Drive
--                        San Jose, CA  95134
--                        USA
--
--                   Tel: +1 800 553-NETS
--
--                E-mail: cs-atm@cisco.com"
--        DESCRIPTION
--                "The MIB for the Cisco/NEC A100 ATM switch."
--        REVISION        "9411170000Z"
--        DESCRIPTION
--                "Initial version of this MIB module."
--        ::= { xxx }

    nec               OBJECT IDENTIFIER ::= { enterprises 119 }
    nec-mib           OBJECT IDENTIFIER ::= { nec 2 }
    necProductDepend  OBJECT IDENTIFIER ::= { nec-mib 3 }
    atomis-mib        OBJECT IDENTIFIER ::= { necProductDepend 14 }
    m5core-mib        OBJECT IDENTIFIER ::= { atomis-mib 3 }


--     MIB Groups
--
--     Node group
    node              OBJECT IDENTIFIER ::= { m5core-mib 1 }
--     Line interface group
    linf              OBJECT IDENTIFIER ::= { m5core-mib 2 }
--     Connection group
    conn              OBJECT IDENTIFIER ::= { m5core-mib 3 }
--     Performance group
    perf              OBJECT IDENTIFIER ::= { m5core-mib 4 }



--        The Node Group

nodeOperStatus OBJECT-TYPE
    SYNTAX        INTEGER {
                    down(1),
                    active(2),
                    off-line(3),
                    testing(4),
                    initializing(5)
            }
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "Operational status of the Model 5."
    ::= { node 1 }

nodeIfConfTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF NodeIfConfEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
            "Configuration of the line cards."
    ::= { node 2 }

nodeIfConfEntry OBJECT-TYPE
    SYNTAX        NodeIfConfEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
            "-"
    INDEX        { nodeIfConfIndex }
    ::= { nodeIfConfTable 1 }

NodeIfConfEntry ::= SEQUENCE {
    nodeIfConfIndex      INTEGER,
    nodeIfConfPhysType   INTEGER,
    nodeIfConfRev        DisplayString,
    nodeIfConfStatus     INTEGER
}

nodeIfConfIndex OBJECT-TYPE
    SYNTAX        INTEGER
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "The index of the table."
    ::= { nodeIfConfEntry 1 }

nodeIfConfPhysType OBJECT-TYPE
    SYNTAX        INTEGER {
                    other(1),
                    sar(2),
                    taxi100M(3),
                    oc3cSMF(4),
                    oc-3cMMF(5),
                    ds3-PLCP-SCRAMBLE(6),
                    ds3-PLCP-noScramble(7),
                    relay-6Mcel(8),
                    notInstalled(99)
            }
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "The PMD/physical layer format of the line cards."
    ::= { nodeIfConfEntry 2 }

nodeIfConfRev OBJECT-TYPE
    SYNTAX        DisplayString
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "The revision of the line cards.
            Implemented by JUL/1994."
    ::= { nodeIfConfEntry 3 }

nodeIfConfStatus OBJECT-TYPE
    SYNTAX        INTEGER {
                    other(1),
                    inService(2),
                    outOfService(3),
                    testing(4),
                    localLoopBack(5),
                    remoteLoopBack(6),
                    notInstalled(99)
            }
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "Operational status of the line cards."
    ::= { nodeIfConfEntry 4 }

nodeFanStatus OBJECT-TYPE
    SYNTAX        INTEGER {
                    up(1),
                    down(2)
            }
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            "Operational status of the FAN."
    ::= { node 3 }

nodeUpcWindowSize OBJECT-TYPE
    SYNTAX        INTEGER (1..120)
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "UPC window size. Integer Wi represents Wi X 512 cell time. 
            Wi=1 correspond to 1.4msec. Wi=120 correspond to 168msec.
            It is not allowed to change window size when the PVC is 
            exsisting."
    ::= { node 4 }

nodeBestEffortBufferSize OBJECT-TYPE
    SYNTAX        INTEGER (0..16)
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "Input buffer capacity for Best Effort traffic(Bb). The number 
            of cells stored in the buffer is Bb X 128. The default value is
            0. The sum of the buffer capacity is 2047 cells."
    ::= { node 5 }

nodeGuaranteedBufferSize OBJECT-TYPE
    SYNTAX        INTEGER (0..16)
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "Input buffer capacity for Guaranteed traffic(Bg). The number 
            of cells stored in the buffer is Bg X 128. The default value is
            0. The sum of the buffer capacity is 2047 cells."
    ::= { node 6 }

nodeBestEffortBufferThreshold OBJECT-TYPE
    SYNTAX        INTEGER (0..16)
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "Threshold buffer capacity for Best Effort traffic. If the 
            number of cells stored in the buffer exceeds this threshold,
            cells with CLP=1 and traffic defined as UBR will be discarded."
    ::= { node 7 }

nodeGuaranteedBufferThreshold OBJECT-TYPE
    SYNTAX        INTEGER (0..16)
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "Threshold buffer capacity for Guaranteed traffic. If the 
            number of cells stored in the buffer exceeds this threshold,
            cells with CLP=1 and traffic defined as VBR will be discarded."
    ::= { node 8 }

nodeSaveConf OBJECT-TYPE
    SYNTAX        INTEGER {
                    save(1)
            }
    ACCESS        write-only
    STATUS  mandatory
    DESCRIPTION
            "Save system configuration information including PVC/SVC table
             to the non-volatile memory. save(1) shall be written in case
             of saving the configiration data."
    ::= { node 9 }

nodeSaveResult OBJECT-TYPE
    SYNTAX        INTEGER {
                    temporaryFailure(1),                        
                    notReady(2),
                    ready(3),
                    succeed(4),
                    nearend(5)
            }
    ACCESS        read-only
    STATUS  mandatory
    DESCRIPTION
            "Show the result of the save command issued from NMS. 
             The result is either Succeed/temporary failure/notReady. 
             nearend will be returned if the number of access times 
             has exceeded the limit."
    ::= { node 10 }


--        The Linf Group

linfStatusTable OBJECT-TYPE
    SYNTAX        SEQUENCE OF LinfStatusEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
            "Status of the line card including ATM specific information."
    ::= { linf 1 }

linfStatusEntry OBJECT-TYPE
    SYNTAX        LinfStatusEntry
    ACCESS        not-accessible
    STATUS        mandatory
    DESCRIPTION
            " - "
    INDEX        { linfIndex }
    ::= { linfStatusTable 1 }

LinfStatusEntry ::= SEQUENCE {
    linfIndex      INTEGER,
    linfStatus     INTEGER,
    linfConf       INTEGER
    }

linfIndex OBJECT-TYPE
    SYNTAX        INTEGER(1..64)
    ACCESS        read-only
    STATUS        mandatory
    DESCRIPTION
            " - "
    ::= { linfStatusEntry 1 }
            
linfStatus OBJECT-TYPE
    SYNTAX  INTEGER {
                    normal(1),
                    los(2),
                    lof(3),
                    loc(4),
                    ais(5),
                    yellow-line(6),
                    yellow-path(7),
                    lop(8),
                    notInstalled(99)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "Status of the line cards"
    ::= { linfStatusEntry 2 }

linfConf OBJECT-TYPE
    SYNTAX        INTEGER {
                    public-UNI(1),
                    private-UNI(2),
                    private-NNI(3),
                    others(99)
            }
    ACCESS        read-write
    STATUS        mandatory
    DESCRIPTION
            "Line card type."
    ::= {  linfStatusEntry  3 }

--        The Conn (Connection & Traffic for accounting) Group

-- to be included in next release

--        The Perf (Performance) Group

-- to be included in next release
 
END