A100-R1-MIB device MIB details by NEC Corporation
A100-R1-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing A100-R1-MIB.
Vendor: | NEC Corporation |
---|---|
Mib: | A100-R1-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- -- Copyright (c) 1994 by cisco Systems, Inc. -- All rights reserved. -- -------------------------------------------------------------------- A100-R1-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; -- ciscoA100Mib MODULE-IDENTITY -- LAST-UPDATED "9411170000Z" -- ORGANIZATION "Cisco Systems, Inc." -- CONTACT-INFO -- " Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-atm@cisco.com" -- DESCRIPTION -- "The MIB for the Cisco/NEC A100 ATM switch." -- REVISION "9411170000Z" -- DESCRIPTION -- "Initial version of this MIB module." -- ::= { xxx } nec OBJECT IDENTIFIER ::= { enterprises 119 } nec-mib OBJECT IDENTIFIER ::= { nec 2 } necProductDepend OBJECT IDENTIFIER ::= { nec-mib 3 } atomis-mib OBJECT IDENTIFIER ::= { necProductDepend 14 } m5core-mib OBJECT IDENTIFIER ::= { atomis-mib 3 } -- MIB Groups -- -- Node group node OBJECT IDENTIFIER ::= { m5core-mib 1 } -- Line interface group linf OBJECT IDENTIFIER ::= { m5core-mib 2 } -- Connection group conn OBJECT IDENTIFIER ::= { m5core-mib 3 } -- Performance group perf OBJECT IDENTIFIER ::= { m5core-mib 4 } -- The Node Group nodeOperStatus OBJECT-TYPE SYNTAX INTEGER { down(1), active(2), off-line(3), testing(4), initializing(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Operational status of the Model 5." ::= { node 1 } nodeIfConfTable OBJECT-TYPE SYNTAX SEQUENCE OF NodeIfConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration of the line cards." ::= { node 2 } nodeIfConfEntry OBJECT-TYPE SYNTAX NodeIfConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "-" INDEX { nodeIfConfIndex } ::= { nodeIfConfTable 1 } NodeIfConfEntry ::= SEQUENCE { nodeIfConfIndex INTEGER, nodeIfConfPhysType INTEGER, nodeIfConfRev DisplayString, nodeIfConfStatus INTEGER } nodeIfConfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the table." ::= { nodeIfConfEntry 1 } nodeIfConfPhysType OBJECT-TYPE SYNTAX INTEGER { other(1), sar(2), taxi100M(3), oc3cSMF(4), oc-3cMMF(5), ds3-PLCP-SCRAMBLE(6), ds3-PLCP-noScramble(7), relay-6Mcel(8), notInstalled(99) } ACCESS read-only STATUS mandatory DESCRIPTION "The PMD/physical layer format of the line cards." ::= { nodeIfConfEntry 2 } nodeIfConfRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the line cards. Implemented by JUL/1994." ::= { nodeIfConfEntry 3 } nodeIfConfStatus OBJECT-TYPE SYNTAX INTEGER { other(1), inService(2), outOfService(3), testing(4), localLoopBack(5), remoteLoopBack(6), notInstalled(99) } ACCESS read-only STATUS mandatory DESCRIPTION "Operational status of the line cards." ::= { nodeIfConfEntry 4 } nodeFanStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Operational status of the FAN." ::= { node 3 } nodeUpcWindowSize OBJECT-TYPE SYNTAX INTEGER (1..120) ACCESS read-write STATUS mandatory DESCRIPTION "UPC window size. Integer Wi represents Wi X 512 cell time. Wi=1 correspond to 1.4msec. Wi=120 correspond to 168msec. It is not allowed to change window size when the PVC is exsisting." ::= { node 4 } nodeBestEffortBufferSize OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "Input buffer capacity for Best Effort traffic(Bb). The number of cells stored in the buffer is Bb X 128. The default value is 0. The sum of the buffer capacity is 2047 cells." ::= { node 5 } nodeGuaranteedBufferSize OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "Input buffer capacity for Guaranteed traffic(Bg). The number of cells stored in the buffer is Bg X 128. The default value is 0. The sum of the buffer capacity is 2047 cells." ::= { node 6 } nodeBestEffortBufferThreshold OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "Threshold buffer capacity for Best Effort traffic. If the number of cells stored in the buffer exceeds this threshold, cells with CLP=1 and traffic defined as UBR will be discarded." ::= { node 7 } nodeGuaranteedBufferThreshold OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "Threshold buffer capacity for Guaranteed traffic. If the number of cells stored in the buffer exceeds this threshold, cells with CLP=1 and traffic defined as VBR will be discarded." ::= { node 8 } nodeSaveConf OBJECT-TYPE SYNTAX INTEGER { save(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Save system configuration information including PVC/SVC table to the non-volatile memory. save(1) shall be written in case of saving the configiration data." ::= { node 9 } nodeSaveResult OBJECT-TYPE SYNTAX INTEGER { temporaryFailure(1), notReady(2), ready(3), succeed(4), nearend(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Show the result of the save command issued from NMS. The result is either Succeed/temporary failure/notReady. nearend will be returned if the number of access times has exceeded the limit." ::= { node 10 } -- The Linf Group linfStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF LinfStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status of the line card including ATM specific information." ::= { linf 1 } linfStatusEntry OBJECT-TYPE SYNTAX LinfStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " - " INDEX { linfIndex } ::= { linfStatusTable 1 } LinfStatusEntry ::= SEQUENCE { linfIndex INTEGER, linfStatus INTEGER, linfConf INTEGER } linfIndex OBJECT-TYPE SYNTAX INTEGER(1..64) ACCESS read-only STATUS mandatory DESCRIPTION " - " ::= { linfStatusEntry 1 } linfStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), los(2), lof(3), loc(4), ais(5), yellow-line(6), yellow-path(7), lop(8), notInstalled(99) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the line cards" ::= { linfStatusEntry 2 } linfConf OBJECT-TYPE SYNTAX INTEGER { public-UNI(1), private-UNI(2), private-NNI(3), others(99) } ACCESS read-write STATUS mandatory DESCRIPTION "Line card type." ::= { linfStatusEntry 3 } -- The Conn (Connection & Traffic for accounting) Group -- to be included in next release -- The Perf (Performance) Group -- to be included in next release END