ons15501SysDevFlash1Image |
.1.3.6.1.4.1.1869.11.11.1.1 |
Gives the name of the software programmed on flash
bank one.
|
ons15501SysDevFlash2Image |
.1.3.6.1.4.1.1869.11.11.1.2 |
Gives the name of the software programmed on flash
bank two.
|
ons15501SysDevFlash3Image |
.1.3.6.1.4.1.1869.11.11.1.3 |
Gives the name of the software programmed on flash
bank three.
|
ons15501SysSwDownload |
.1.3.6.1.4.1.1869.11.11.1.4 |
Used to control the image download to the flash banks.
NOTE: Read on this attribute returns the last t/ftp command,
without login/password.
For s/w release 4.0 and above, the value read back
includes the Kilo-Bytes downloaded for last download
command.
It is the size of file downloaded (in KB), if the
download has completed. If a download is in progress
this value would correspond to Kilo-Bytes successfully
downloaded so far.
For set the string syntax is one of the following
a. abort
- Aborts the current download
b. ftp:<svr-IP>:<login>:<pass>:<path>:<fName>:<flash#>[:passive]
- Download image using ftp
c. tftp:<srvr-IP>:<fName>:<flashNo>
- Download image using tftp
where
<svr-IP> - is t/ftp server name
<login> - is login to be used for ftp (default anonymous)
<pass> - password for the login name for ftp
(default - no passwd - passwd is empty string)
<path> - path to be given on ftp prompt for cd
(default - skip cd command )
<fName> - name of the file to be downloaded and burnt
to the flash - NO DEFAULTS - because the
filename is used as distinguishing versions
there are no defaults for this command.
For TFTP Path information is part of the filename
<flash#> - which flash has to be burnt [1|2|3]
NOTE: Burn to active bank fails
passive - if `passive` is specified, ftp is done using
passive mode (provided for FTP download across
firewall).
NOTE: None of the fields should contain ':' within them, as
it is used as field separator.
|
ons15501SysDevActiveImage |
.1.3.6.1.4.1.1869.11.11.1.5 |
Show currently active image's bank number.
This may be different from ons15501SysConfiguredActiveImage,
if
a. The image on ons15501SysConfiguredActiveImage did not
boot properly.
b. User chose another bank during bootup, using the
serial console port.
|
ons15501SysDeviceManagerList |
.1.3.6.1.4.1.1869.11.11.1.6 |
A ',' separated list of managers that will receive the
Traps.
If a specific host should receive the traps sent from this
unit, it should be added to the list using CLI.
Up to 16 managers can be present in this list.
|
ons15501SysSwDownloadStatus |
.1.3.6.1.4.1.1869.11.11.1.7 |
Denotes the FTP/TFTP status. Please refer to the description
of Ons15501ImageDnLoadStatus for a list of supported values
|
ons15501SysConfiguredImage |
.1.3.6.1.4.1.1869.11.11.1.8 |
Set/Show configured value for flash-bank number to be used
on reboot.
A set on this attribute will result in a reboot of the system.
To restart the system, write back the same value as the
one read from it (or from ons15501SysDevActiveImage).
|
ons15501CLEICode |
.1.3.6.1.4.1.1869.11.11.1.9 |
This attribute represents the CLEI (Common Language
Equipment Identifier) code for the ONS15501.
|
ons15501PrimaryNTP |
.1.3.6.1.4.1.1869.11.11.1.10 |
The IP address for the primary NTP server.
|
ons15501SecondaryNTP |
.1.3.6.1.4.1.1869.11.11.1.11 |
The IP address for the secondary NTP server.
|
ons15501NTPAdminStatus |
.1.3.6.1.4.1.1869.11.11.1.12 |
The configured administrative status for NTP.
|
ons15501NTPOperationalStatus |
.1.3.6.1.4.1.1869.11.11.1.13 |
The operational status for NTP.
|
ons15501ActiveSoftwareVer |
.1.3.6.1.4.1.1869.11.11.1.14 |
This attribute provides the active software version.
This will be same as the entPhysicalSoftwareRev for
the entry corresponding to the chassis.
|
ons15501LastConfigChangeTime |
.1.3.6.1.4.1.1869.11.11.1.15 |
The value of sysUpTime when last configuration
change was done.
NMS may use this information to synchronize if
some configuration has changed on the unit.
|
ons15501InRemoteInfoUpdateTime |
.1.3.6.1.4.1.1869.11.11.1.16 |
This attribute gives the time-stamp when one or more of
ons15501InRemoteChassisName, ons15501InRemotePortName,
or ons15501InRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit.
|
ons15501InRemoteChassisName |
.1.3.6.1.4.1.1869.11.11.1.17 |
Manager initialized string value to identify the
chassis associated with remote connection for
optical input.
ons15501InRemoteChassisName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.
|
ons15501InRemotePortName |
.1.3.6.1.4.1.1869.11.11.1.18 |
Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical input.
ons15501InRemotePortName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.
|
ons15501InRemoteAgentIpAddr |
.1.3.6.1.4.1.1869.11.11.1.19 |
Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
providing optical input.
ons15501InRemoteAgentIpAddr would be a 0.0.0.0
if the input link is disabled.
To disable the input link entry set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.
|
ons15501OutRemoteInfoUpdateTime |
.1.3.6.1.4.1.1869.11.11.1.20 |
This attribute gives the time-stamp when one or more of
ons15501OutRemoteChassisName, ons15501OutRemotePortName,
or ons15501OutRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit.
|
ons15501OutRemoteChassisName |
.1.3.6.1.4.1.1869.11.11.1.21 |
Manager initialized string value to identify the
chassis associated with remote connection for
optical output.
ons15501OutRemoteChassisName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
|
ons15501OutRemotePortName |
.1.3.6.1.4.1.1869.11.11.1.22 |
Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical output.
ons15501OutRemotePortName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
|
ons15501OutRemoteAgentIpAddr |
.1.3.6.1.4.1.1869.11.11.1.23 |
Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
using optical output.
ons15501OutRemoteAgentIpAddr would be a 0.0.0.0
if the output link is disabled.
To disable the output link entry set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
|
ons15501SysAlarmStatus |
.1.3.6.1.4.1.1869.11.11.1.24 |
Provides the highest severity alarm currently active.
|
ons15501SysDateAndTime |
.1.3.6.1.4.1.1869.11.11.1.25 |
The date and time of the System.
The write will not succeed if the administrative
state for NTP (ons15501NTPAdminStatus)
is 'enabled'.
Setting this attribute will autmatically change
values for ons15501TrapLogEntryDateAndTime and
ons15501ActAlarmDateAndTime.
|
ons15501LastTrapIndex |
.1.3.6.1.4.1.1869.11.11.3.1 |
The value of ons15501TrapLogEntryIndex, used while logging
the most recent trap. Goes back to 1, after reaching
the max value.
The trap log table is a circular list with the most
recent entry at index given by this attribute.
On restart of the unit, the value is reset to 1.
|
ons15501TrapLogEntry |
.1.3.6.1.4.1.1869.11.11.3.2.1 |
Entry for a trap
|
ons15501ActiveAlarmEntry |
.1.3.6.1.4.1.1869.11.11.3.3.1 |
Entry for an active alarm condition.
For each alarm condition present on the
equipment, there would be an entry in
the table.
|
ons15501TrapDescriptionEntry |
.1.3.6.1.4.1.1869.11.11.3.4.1 |
Entry for textual information about traps.
|
ons15501InputOpticalPower |
.1.3.6.1.4.1.1869.11.11.2.1 |
The optical power being fed into the Amplifier.
|
ons15501InputOpticalPowerMean |
.1.3.6.1.4.1.1869.11.11.2.2 |
Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.
|
ons15501InputOpticalPowerTrigger |
.1.3.6.1.4.1.1869.11.11.2.3 |
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
input optical power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501InputOpticalPowerMean above.
|
ons15501OutputOpticalPower |
.1.3.6.1.4.1.1869.11.11.2.4 |
The measured value for raw optical power being
generated at the output of the Amplifier.
|
ons15501OutputSignalPower |
.1.3.6.1.4.1.1869.11.11.2.5 |
The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +-----------------------+-------------->
-29 dBm -10 dBm
Input Optical Power
|
ons15501OutputSignalPowerMean |
.1.3.6.1.4.1.1869.11.11.2.6 |
Mean value for output optical power.
If the output signal power falls below (or goes
above) the mean value by more than trigger
(see ons15501OutputSignalPowerTrigger) an alarm
is generated. The alarm is cleared when the
output optical power is back within 90% of trigger
from the mean.
|
ons15501OutputSignalPowerTrigger |
.1.3.6.1.4.1.1869.11.11.2.7 |
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
output signal power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501OutputSignalPowerMean above.
|
ons15501ConfigOpticalGain |
.1.3.6.1.4.1.1869.11.11.2.8 |
The configured value for power gain.
|
ons15501OpticalPowerGain |
.1.3.6.1.4.1.1869.11.11.2.9 |
The measured value for power gain.
This value does not include the amplification
noise that is significant for low input signals.
|
ons15501GainTrigger |
.1.3.6.1.4.1.1869.11.11.2.10 |
The gain deviation allowed from the configured gain
before an alarm is asserted. The alarm is not cleared,
until measured gain(ons15501OpticalPowerGain) is back
within 90% of ons15501GainTrigger from configured gain
(ons15501ConfigOpticalGain).
|
ons15501PowerSupply1Level |
.1.3.6.1.4.1.1869.11.11.2.11 |
The voltage fed through power supply 1.
The value of the attribute is 10 times the
the value in volts.
|
ons15501PowerSupply2Level |
.1.3.6.1.4.1.1869.11.11.2.12 |
The voltage fed through power supply 2.
The value of the attribute is 10 times the
the value in volts.
|
ons15501LaserStatus |
.1.3.6.1.4.1.1869.11.11.2.13 |
Gives the status of the laser pumps.
|
ons15501DevAmbTemp |
.1.3.6.1.4.1.1869.11.11.2.14 |
The ambient temperature for the device.
|
ons15501DevAmbTempMean |
.1.3.6.1.4.1.1869.11.11.2.15 |
Mean value for temperature.
If the temperature falls below (or goes above) the
mean value by more than trigger level (see
ons15501DevAmbTempTrigger) an alarm is generated.
The alarm is cleared when the temperature is back
within 90% of trigger value, from the mean.
|
ons15501DevAmbTempTrigger |
.1.3.6.1.4.1.1869.11.11.2.16 |
Please refer to ons15501DevAmbTempMean above.
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
temperature falls back within 90% of the value.
|
ons15501PowerSupply1Status |
.1.3.6.1.4.1.1869.11.11.2.17 |
Gives the status of power supply one.
|
ons15501PowerSupply2Status |
.1.3.6.1.4.1.1869.11.11.2.18 |
Gives the status of power supply two.
|
ons15501TrapLogEntryIndex |
.1.3.6.1.4.1.1869.11.11.3.2.1.1 |
index field for this entry. Actual range at
run time is ons15501TrapCounter to
ons15501TrapCounter - N + 1 or 1
(whichever is higher)
|
ons15501TrapLogEntryTrapType |
.1.3.6.1.4.1.1869.11.11.3.2.1.2 |
The type of trap. See the definition
of Ons15501TrapTypeEnumeration for possible values.
|
ons15501TrapLogEntryDirection |
.1.3.6.1.4.1.1869.11.11.3.2.1.3 |
Whether the trap is being asserted or cleared.
Please note that some traps don't have a direction.
(e.g. configuration changed).
|
ons15501TrapLogEntryTimeStamp |
.1.3.6.1.4.1.1869.11.11.3.2.1.4 |
The value of sysUpTime when the entry was placed in
the log.
|
ons15501TrapLogEntryDateAndTime |
.1.3.6.1.4.1.1869.11.11.3.2.1.5 |
The local date and time at which the entry was placed in
the log.
|
ons15501TrapLogEntryPhyIndex |
.1.3.6.1.4.1.1869.11.11.3.2.1.6 |
Provides entPhysicalIndex value for the physical entity
corresponding to the trap entry.
|
ons15501TrapLogEntrySeverity |
.1.3.6.1.4.1.1869.11.11.3.2.1.7 |
Provides the severity level corresponding to this
trap entry.
|
ons15501ActAlarmType |
.1.3.6.1.4.1.1869.11.11.3.3.1.1 |
Index field for ons15501ActiveAlarmTable.
Presence of an entry implies that the specific
alarm type is active on the unit.
|
ons15501ActAlarmTimeStamp |
.1.3.6.1.4.1.1869.11.11.3.3.1.2 |
The time since when the alarm is active.
|
ons15501ActAlarmDateAndTime |
.1.3.6.1.4.1.1869.11.11.3.3.1.3 |
The local date and time since when the alarm is active
|
ons15501ActAlarmPhyIndex |
.1.3.6.1.4.1.1869.11.11.3.3.1.4 |
Provides entPhysicalIndex value for the physical entity
corresponding to the alarm entry.
|
ons15501ActAlarmSeverity |
.1.3.6.1.4.1.1869.11.11.3.3.1.5 |
Provides the severity level corresponding to this
alarm entry.
|
ons15501TrapTypeValue |
.1.3.6.1.4.1.1869.11.11.3.4.1.1 |
Index field for this entry.
|
ons15501TrapDescription |
.1.3.6.1.4.1.1869.11.11.3.4.1.2 |
The textual information corresponding to the
ons15501TrapTypeValue.
|
ons15501TrapSeverity |
.1.3.6.1.4.1.1869.11.11.3.4.1.3 |
Provides the default severity level corresponding
to the ons15501TrapTypeValue.
|