The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing DS3-MIB.


Vendor: RFC
Mib: DS3-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- WinAgents MIB Extraction Wizard
-- Extracted from rfc3896.txt 16.03.2005 20:22:03

DS3-MIB DEFINITIONS ::= BEGIN

IMPORTS
     MODULE-IDENTITY, OBJECT-TYPE,
     NOTIFICATION-TYPE, transmission
          FROM SNMPv2-SMI                    -- [RFC2578]
     DisplayString, TimeStamp, TruthValue
          FROM SNMPv2-TC                     -- [RFC2579]
     MODULE-COMPLIANCE, OBJECT-GROUP,
     NOTIFICATION-GROUP
          FROM SNMPv2-CONF                   -- [RFC2580]
     InterfaceIndex
          FROM IF-MIB                        -- [RFC2863]
     PerfCurrentCount, PerfIntervalCount,
     PerfTotalCount
          FROM PerfHist-TC-MIB;              -- [RFC3593]


ds3 MODULE-IDENTITY
    LAST-UPDATED "200409080000Z"  -- September 08, 2004
    ORGANIZATION "IETF AToM MIB Working Group"
    CONTACT-INFO
      "WG charter:
         http://www.ietf.org/html.charters/atommib-charter.html

       Mailing Lists:
         General Discussion: atommib@research.telcordia.com
         To Subscribe: atommib-request@research.telcordia.com

       Editor: Orly Nicklass

       Postal: RAD Data Communications, Ltd.
               Ziv Tower, 24 Roul Walenberg
               Tel Aviv, Israel, 69719

               Tel: +9723 765 9969
       E-mail: orly_n@rad.com"

    DESCRIPTION
         "The is the MIB module that describes
          DS3 and E3 interfaces objects.

          Copyright (c) The Internet Society (2004).  This
          version of this MIB module is part of RFC 3896;
          see the RFC itself for full legal notices."

    REVISION "200409080000Z"  -- September 08, 2004

     DESCRIPTION
          "The RFC 3896 version of this MIB module.
          The key changes made to this MIB module
          since its publication in RFC 2496 are as follows:

      (1) The dsx3FracIfIndex SYNTAX matches the description range.

      (2) Reference was added to Circuit Identifier object.

      (3) Usage of ifStackTable section was updated.

      (4) Align the DESCRIPTION clauses of few statistic objects with
          thenear end definition, the far end definition and with
          RFC 3593.

      (5) Add new value, dsx3M13, to dsx3LineType."

     REVISION "199808012130Z"

     DESCRIPTION
          "The RFC 2496 version of this MIB module.
          The key changes made to this MIB module
          since its publication in RFC 1407 are as follows:

         (1)  The Fractional Table has been deprecated.

         (2)  This document uses SMIv2.

         (3)  Values are given for ifTable and ifXTable.

         (4)  Example usage of ifStackTable is included.

         (5)  dsx3IfIndex has been deprecated.

         (6)  The definition of valid intervals has been clarified
              for the case where the agent proxied for other devices.
              In particular, the treatment of missing intervals has
              been clarified.

        (7)  An inward loopback has been added.

        (8)  Additional lineStatus bits have been added for Near End
             in Unavailable Signal State, Carrier Equipment Out of
             Service.

        (9)  A read-write line Length object has been added.

        (10) Added a lineStatus last change, trap and enabler.

        (11) Textual Conventions for statistics objects have
             been used.

        (12) A new object, dsx3LoopbackStatus, has been introduced to
             reflect the loopbacks established on a DS3/E3 interface
             and the source to the requests.  dsx3LoopbackConfig
             continues to be the desired loopback state while
             dsx3LoopbackStatus reflects the actual state.

        (13) A dual loopback has been added to allow the setting of
             an inward loopback and a line loopback at the same time.

        (14) An object has been added to indicated whether or not
             this is a channelized DS3/E3.

        (15) A new object has been added to indicate which DS1 is to
             set for remote loopback."


    REVISION "199301252028Z"
    DESCRIPTION
         "Initial version, published as RFC 1407."
    ::= { transmission 30 }

-- The DS3/E3 Near End Group

-- The DS3/E3 Near End Group consists of four tables:
--    DS3/E3 Configuration
--    DS3/E3 Current
--    DS3/E3 Interval
--    DS3/E3 Total

-- the DS3/E3 Configuration Table

dsx3ConfigTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3ConfigEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3/E3 Configuration table."
     ::= { ds3 5 }

dsx3ConfigEntry OBJECT-TYPE
     SYNTAX  Dsx3ConfigEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3/E3 Configuration table."
     INDEX   { dsx3LineIndex }
     ::= { dsx3ConfigTable 1 }

Dsx3ConfigEntry ::=
     SEQUENCE {
         dsx3LineIndex                        InterfaceIndex,
         dsx3IfIndex                          InterfaceIndex,
         dsx3TimeElapsed                      INTEGER,
         dsx3ValidIntervals                   INTEGER,
         dsx3LineType                         INTEGER,
         dsx3LineCoding                       INTEGER,
         dsx3SendCode                         INTEGER,
         dsx3CircuitIdentifier                DisplayString,
         dsx3LoopbackConfig                   INTEGER,
         dsx3LineStatus                       INTEGER,
         dsx3TransmitClockSource              INTEGER,
         dsx3InvalidIntervals                 INTEGER,
         dsx3LineLength                       INTEGER,
         dsx3LineStatusLastChange             TimeStamp,

         dsx3LineStatusChangeTrapEnable       INTEGER,
         dsx3LoopbackStatus                   INTEGER,
         dsx3Channelization                   INTEGER,
         dsx3Ds1ForRemoteLoop                 INTEGER

}

dsx3LineIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index

     STATUS  current
     DESCRIPTION
            "This object should be made equal to ifIndex.  The
            next paragraph describes its previous usage.
            Making the object equal to ifIndex allows proper
            use of ifStackTable.

            Previously, this object was the identifier of a
            DS3/E3 Interface on a managed device.  If there is
            an ifEntry that is directly associated with this
            and only this DS3/E3 interface, it should have the
            same value as ifIndex.  Otherwise, number the
            dsx3LineIndices with an unique identifier
            following the rules of choosing a number that is
            greater than ifNumber and numbering the inside
            interfaces (e.g., equipment side) with even
            numbers and outside interfaces (e.g., network side)
            with odd numbers."
     ::= { dsx3ConfigEntry 1 }

dsx3IfIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only
     STATUS  deprecated
     DESCRIPTION
            "This value for this object is equal to the value
            of ifIndex from the Interfaces table of MIB II
            (RFC 1213)."
     ::= { dsx3ConfigEntry 2 }

dsx3TimeElapsed OBJECT-TYPE
     SYNTAX  INTEGER (0..899)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of seconds that have elapsed since the

            beginning of the near end current error-
            measurement period. If, for some reason, such as
            an adjustment in the system's time-of-day clock,
            the current interval exceeds the maximum value,
            the agent will return the maximum value."
     ::= { dsx3ConfigEntry 3 }

dsx3ValidIntervals OBJECT-TYPE
     SYNTAX  INTEGER (0..96)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of previous near end intervals for
            which data was collected.  The value will be 96
            unless the interface was brought online within the
            last 24 hours, in which case the value will be the
            number of complete 15 minute near end intervals
            since the interface has been online.  In the case
            where the agent is a proxy, it is possible that
            some intervals are unavailable.  In this case,
            this interval is the maximum interval number for
            which data is available."
     ::= { dsx3ConfigEntry 4 }

dsx3LineType OBJECT-TYPE
     SYNTAX  INTEGER {
                dsx3other(1),
                dsx3M23(2),
                dsx3SYNTRAN(3),
                dsx3CbitParity(4),
                dsx3ClearChannel(5),
                e3other(6),
                e3Framed(7),
                e3Plcp(8),
                dsx3M13(9)
            }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This variable indicates the variety of DS3 C-bit
            or E3 application implementing this interface. The
            type of interface affects the interpretation of
            the usage and error statistics.  The rate of DS3
            is 44.736 Mbps and E3 is 34.368 Mbps.  The
            dsx3ClearChannel value means that the C-bits are
            not used except for sending/receiving AIS.  The
            values, in sequence, describe:


                           TITLE:          SPECIFICATION:
                           dsx3M23         ANSI T1.107-1988
                           dsx3SYNTRAN     ANSI T1.107-1988
                           dsx3CbitParity  ANSI T1.107a-1990
                           dsx3ClearChannel ANSI T1.102-1987
                           e3Framed        CCITT G.751
                           e3Plcp          ETSI T/NA(91)18
                           dsx3M13         ANSI T1.107a-1990."

    REFERENCE
            "American National Standard for telecommunications
                 - digital hierarchy -
                 formats specification, ANSI T1.107- 1988.
                 ANSI T1.107a-1990.
             American National Standard for telecommunications
                 - digital hierarchy -
                 electrical interfaces, ANSI T1.102- 1987.
             CCITT - Digital Multiplex Equipment Operating at
                 the Third Order Bit Rate of 34 368 Kbit/s and
                 the Forth Order Bit Rate of 139 264 Kbit/s
                 and Using Positive Justification, G.751
             European Telecommunications Standards Institute
                 -- ETS '34M' --
                 Metropolitan Area Network Physical
                 Convergence Layer Procedure for
                 34.368 Megabits per Second, T/NA(91)18,
                 May 1991."
     ::= { dsx3ConfigEntry 5 }

dsx3LineCoding OBJECT-TYPE
     SYNTAX  INTEGER {
                dsx3Other(1),
                dsx3B3ZS(2),
                e3HDB3(3)
            }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This variable describes the variety of Zero Code
            Suppression used on this interface, which in turn
            affects a number of its characteristics.
            dsx3B3ZS and e3HDB3 refer to the use of specified
            patterns of normal bits and bipolar violations
            which are used to replace sequences of zero bits
            of a specified length."
     ::= { dsx3ConfigEntry 6 }

dsx3SendCode OBJECT-TYPE

     SYNTAX  INTEGER {
               dsx3SendNoCode(1),
               dsx3SendLineCode(2),
               dsx3SendPayloadCode(3),
               dsx3SendResetCode(4),
               dsx3SendDS1LoopCode(5),
               dsx3SendTestPattern(6)
               }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This variable indicates what type of code is
            being sent across the DS3/E3 interface by the
            device.  (These are optional for E3 interfaces.)
            Setting this variable causes the interface to
            begin sending the code requested.
            The values mean:

               dsx3SendNoCode
                   sending looped or normal data

               dsx3SendLineCode
                   sending a request for a line loopback

               dsx3SendPayloadCode
                   sending a request for a payload loopback
                   (i.e., all DS1/E1s in a DS3/E3 frame)

               dsx3SendResetCode
                   sending a loopback deactivation request

               dsx3SendDS1LoopCode
                   requesting to loopback a particular DS1/E1
                   within a DS3/E3 frame.  The DS1/E1 is
                   indicated in dsx3Ds1ForRemoteLoop.

               dsx3SendTestPattern
                   sending a test pattern."
     ::= { dsx3ConfigEntry 7 }

dsx3CircuitIdentifier OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (0..255))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This variable contains the transmission vendor's
            circuit identifier, for the purpose of
            facilitating troubleshooting."

     REFERENCE "ITU-T M.1400"
     ::= { dsx3ConfigEntry 8 }

dsx3LoopbackConfig OBJECT-TYPE
     SYNTAX  INTEGER {
                 dsx3NoLoop(1),
                 dsx3PayloadLoop(2),
                 dsx3LineLoop(3),
                 dsx3OtherLoop(4),
                 dsx3InwardLoop(5),
                 dsx3DualLoop(6)
               }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
          "This variable represents the desired loopback
          configuration of the DS3/E3 interface.
          The values mean:

          dsx3NoLoop
            Not in the loopback state.  A device that is
            not capable of performing a loopback on
            the interface shall always return this as
            its value.

          dsx3PayloadLoop
            The received signal at this interface is looped
            through the device.  Typically the received signal
            is looped back for retransmission after it has
            passed through the device's framing function.

          dsx3LineLoop
            The received signal at this interface does not
            go through the device (minimum penetration) but
            is looped back out.

          dsx3OtherLoop
            Loopbacks that are not defined here.

          dsx3InwardLoop
            The sent signal at this interface is looped back
            through the device.

          dsx3DualLoop
            Both dsx1LineLoop and dsx1InwardLoop will be
            active simultaneously."
     ::= { dsx3ConfigEntry 9 }


dsx3LineStatus OBJECT-TYPE
     SYNTAX  INTEGER (1..4095)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "This variable indicates the Line Status of the
            interface.  It contains loopback state information
            and failure state information.  The dsx3LineStatus
            is a bit map represented as a sum, therefore, it
            can represent multiple failures and a loopback
            (see dsx3LoopbackConfig object for the type of
            loopback) simultaneously.  The dsx3NoAlarm must be
            set if and only if no other flag is set.

            If the dsx3loopbackState bit is set, the loopback
            in effect can be determined from the
            dsx3loopbackConfig object.
       The various bit positions are:
        1     dsx3NoAlarm         No alarm present
        2     dsx3RcvRAIFailure   Receiving Yellow/Remote
                                  Alarm Indication
        4     dsx3XmitRAIAlarm    Transmitting Yellow/Remote
                                  Alarm Indication
        8     dsx3RcvAIS          Receiving AIS failure state
       16     dsx3XmitAIS         Transmitting AIS
       32     dsx3LOF             Receiving LOF failure state
       64     dsx3LOS             Receiving LOS failure state
      128     dsx3LoopbackState   Looping the received signal
      256     dsx3RcvTestCode     Receiving a Test Pattern
      512     dsx3OtherFailure    any line status not defined
                                  here
     1024     dsx3UnavailSigState Near End in Unavailable
                                  Signal State
     2048     dsx3NetEquipOOS     Carrier Equipment Out of
                                  Service"
     ::= { dsx3ConfigEntry 10 }

dsx3TransmitClockSource OBJECT-TYPE
     SYNTAX  INTEGER {
                loopTiming(1),
                localTiming(2),
                throughTiming(3)
            }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "The source of Transmit Clock.


            loopTiming indicates that the recovered receive
            clock is used as the transmit clock.

            localTiming indicates that a local clock source is
            used or that an external clock is attached to the
            box containing the interface.

            throughTiming indicates that transmit clock is
            derived from the recovered receive clock of
            another DS3 interface."
     ::= { dsx3ConfigEntry 11 }

dsx3InvalidIntervals OBJECT-TYPE
     SYNTAX  INTEGER (0..96)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            " The number of intervals in the range from 0 to
            dsx3ValidIntervals for which no data is available.
            This object will typically be zero except in cases
            where the data for some intervals are not
            available (e.g., in proxy situations)."
     ::= { dsx3ConfigEntry 12 }

dsx3LineLength OBJECT-TYPE
     SYNTAX  INTEGER (0..64000)
     UNITS "meters"
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "The length of the ds3 line in meters.  This
            object provides information for line build out
            circuitry if it exists and can use this object to
            adjust the line build out."
     ::= { dsx3ConfigEntry 13 }

dsx3LineStatusLastChange OBJECT-TYPE
     SYNTAX  TimeStamp
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The value of MIB II's sysUpTime object at the
            time this DS3/E3 entered its current line status
            state.  If the current state was entered prior to
            the last re-initialization of the proxy-agent,
            then this object contains a zero value."
     ::= { dsx3ConfigEntry 14 }


dsx3LineStatusChangeTrapEnable  OBJECT-TYPE
     SYNTAX      INTEGER {
                    enabled(1),
                    disabled(2)
                 }
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
            "Indicates whether dsx3LineStatusChange traps
            should be generated for this interface."
     DEFVAL { disabled }
     ::= { dsx3ConfigEntry 15 }

dsx3LoopbackStatus  OBJECT-TYPE
     SYNTAX      INTEGER (1..127)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
            "This variable represents the current state of the
            loopback on the DS3 interface.  It contains
            information about loopbacks established by a
            manager and remotely from the far end.

            The dsx3LoopbackStatus is a bit map represented as
            a sum, therefore is can represent multiple
            loopbacks simultaneously.

            The various bit positions are:
             1  dsx3NoLoopback
             2  dsx3NearEndPayloadLoopback
             4  dsx3NearEndLineLoopback
             8  dsx3NearEndOtherLoopback
            16  dsx3NearEndInwardLoopback
            32  dsx3FarEndPayloadLoopback
            64  dsx3FarEndLineLoopback"
     ::= { dsx3ConfigEntry 16 }

dsx3Channelization  OBJECT-TYPE
     SYNTAX      INTEGER {
                    disabled(1),
                    enabledDs1(2),
                    enabledDs2(3)
                 }
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
            "Indicates whether this ds3/e3 is channelized or
            unchannelized.  The value of enabledDs1 indicates

            that this is a DS3 channelized into DS1s.  The
            value of enabledDs3 indicated that this is a DS3
            channelized into DS2s.  Setting this object will
            cause the creation or deletion of DS2 or DS1
            entries in the ifTable.  "
     ::= { dsx3ConfigEntry 17 }

dsx3Ds1ForRemoteLoop  OBJECT-TYPE
     SYNTAX      INTEGER (0..29)
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
            "Indicates which DS1/E1 on this DS3/E3 will be
            indicated in the remote ds1 loopback request.  A
            value of 0 means no DS1 will be looped.  A value
            of 29 means all DS1s/E1s will be looped."
     ::= { dsx3ConfigEntry 18 }

-- the DS3/E3 Current Table


dsx3CurrentTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3CurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3/E3 current table contains various
            statistics being collected for the current 15
            minute interval."
     ::= { ds3 6 }

dsx3CurrentEntry OBJECT-TYPE
     SYNTAX  Dsx3CurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3/E3 Current table."
     INDEX   { dsx3CurrentIndex }
     ::= { dsx3CurrentTable 1 }

Dsx3CurrentEntry ::=
     SEQUENCE {
         dsx3CurrentIndex           InterfaceIndex,
         dsx3CurrentPESs            PerfCurrentCount,
         dsx3CurrentPSESs           PerfCurrentCount,
         dsx3CurrentSEFSs           PerfCurrentCount,
         dsx3CurrentUASs            PerfCurrentCount,
         dsx3CurrentLCVs            PerfCurrentCount,

         dsx3CurrentPCVs            PerfCurrentCount,
         dsx3CurrentLESs            PerfCurrentCount,
         dsx3CurrentCCVs            PerfCurrentCount,
         dsx3CurrentCESs            PerfCurrentCount,
         dsx3CurrentCSESs           PerfCurrentCount
    }

dsx3CurrentIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
     ::= { dsx3CurrentEntry 1 }

dsx3CurrentPESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds."
     ::= { dsx3CurrentEntry 2 }

dsx3CurrentPSESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds."
     ::= { dsx3CurrentEntry 3 }

dsx3CurrentSEFSs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds."
     ::= { dsx3CurrentEntry 4 }


dsx3CurrentUASs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds."
     ::= { dsx3CurrentEntry 5 }

dsx3CurrentLCVs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations."
     ::= { dsx3CurrentEntry 6 }

dsx3CurrentPCVs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Coding Violations."
     ::= { dsx3CurrentEntry 7 }

dsx3CurrentLESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of Line Errored Seconds."
     ::= { dsx3CurrentEntry 8 }

dsx3CurrentCCVs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of C-bit Coding Violations."
     ::= { dsx3CurrentEntry 9 }

dsx3CurrentCESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION

            "The number of C-bit Errored Seconds."
     ::= { dsx3CurrentEntry 10 }

dsx3CurrentCSESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of C-bit Severely Errored Seconds."
     ::= { dsx3CurrentEntry 11 }

-- the DS3/E3 Interval Table

dsx3IntervalTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3IntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3/E3 Interval Table contains various
            statistics collected by each DS3/E3 Interface over
            the previous 24 hours of operation.  The past 24
            hours are broken into 96 completed 15 minute
            intervals.  Each row in this table represents one
            such interval (identified by dsx3IntervalNumber)
            and for one specific interface (identified by
            dsx3IntervalIndex)."
     ::= { ds3 7 }

dsx3IntervalEntry OBJECT-TYPE
     SYNTAX  Dsx3IntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3/E3 Interval table."
     INDEX   { dsx3IntervalIndex, dsx3IntervalNumber }
     ::= { dsx3IntervalTable 1 }

Dsx3IntervalEntry ::=
     SEQUENCE {
         dsx3IntervalIndex           InterfaceIndex,
         dsx3IntervalNumber          INTEGER,
         dsx3IntervalPESs            PerfIntervalCount,
         dsx3IntervalPSESs           PerfIntervalCount,
         dsx3IntervalSEFSs           PerfIntervalCount,
         dsx3IntervalUASs            PerfIntervalCount,
         dsx3IntervalLCVs            PerfIntervalCount,
         dsx3IntervalPCVs            PerfIntervalCount,
         dsx3IntervalLESs            PerfIntervalCount,

         dsx3IntervalCCVs            PerfIntervalCount,
         dsx3IntervalCESs            PerfIntervalCount,
         dsx3IntervalCSESs           PerfIntervalCount,
         dsx3IntervalValidData       TruthValue
     }

dsx3IntervalIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
     ::= { dsx3IntervalEntry 1 }

dsx3IntervalNumber OBJECT-TYPE
     SYNTAX  INTEGER (1..96)
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "A number between 1 and 96, where 1 is the most
            recently completed 15 minute interval and 96 is
            the 15 minutes interval completed 23 hours and 45
            minutes prior to interval 1."
     ::= { dsx3IntervalEntry 2 }

dsx3IntervalPESs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds."
     ::= { dsx3IntervalEntry 3 }

dsx3IntervalPSESs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds."

     ::= { dsx3IntervalEntry 4 }

dsx3IntervalSEFSs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds."
     ::= { dsx3IntervalEntry 5 }

dsx3IntervalUASs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds.  This object may decrease if
            the occurrence of unavailable seconds occurs across
            an interval boundary."
     ::= { dsx3IntervalEntry 6 }

dsx3IntervalLCVs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations."
     ::= { dsx3IntervalEntry 7 }

dsx3IntervalPCVs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Coding Violations."
     ::= { dsx3IntervalEntry 8 }

dsx3IntervalLESs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of Line Errored  Seconds  (BPVs  or
            illegal  zero  sequences)."
     ::= { dsx3IntervalEntry 9 }

 dsx3IntervalCCVs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
             "The number of C-bit Coding Violations."
      ::= { dsx3IntervalEntry 10 }

 dsx3IntervalCESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
             "The number of C-bit Errored Seconds."
      ::= { dsx3IntervalEntry 11 }

 dsx3IntervalCSESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
             "The number of C-bit Severely Errored Seconds."
      ::= { dsx3IntervalEntry 12 }

 dsx3IntervalValidData OBJECT-TYPE
      SYNTAX  TruthValue
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
             " This variable indicates if the data for this
             interval is valid."
      ::= { dsx3IntervalEntry 13 }

-- the DS3/E3 Total

dsx3TotalTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3TotalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3/E3 Total Table contains the cumulative
            sum of the various statistics for the 24 hour
            period preceding the current interval."
     ::= { ds3 8 }

dsx3TotalEntry OBJECT-TYPE
     SYNTAX  Dsx3TotalEntry
     MAX-ACCESS  not-accessible

     STATUS  current
     DESCRIPTION
            "An entry in the DS3/E3 Total table."
    INDEX   { dsx3TotalIndex }
     ::= { dsx3TotalTable 1 }

Dsx3TotalEntry ::=
     SEQUENCE {
         dsx3TotalIndex      InterfaceIndex,
         dsx3TotalPESs       PerfTotalCount,
         dsx3TotalPSESs      PerfTotalCount,
         dsx3TotalSEFSs      PerfTotalCount,
         dsx3TotalUASs       PerfTotalCount,
         dsx3TotalLCVs       PerfTotalCount,
         dsx3TotalPCVs       PerfTotalCount,
         dsx3TotalLESs       PerfTotalCount,
         dsx3TotalCCVs       PerfTotalCount,
         dsx3TotalCESs       PerfTotalCount,
         dsx3TotalCSESs      PerfTotalCount
     }

dsx3TotalIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
     ::= { dsx3TotalEntry 1 }

dsx3TotalPESs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds, encountered by a DS3 interface in
            the previous 24 hour interval. Invalid 15 minute
            intervals count as 0."
     ::= { dsx3TotalEntry 2 }

dsx3TotalPSESs OBJECT-TYPE
     SYNTAX  PerfTotalCount

     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds, encountered by a DS3
            interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 3 }

dsx3TotalSEFSs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds, encountered by a
            DS3/E3 interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 4 }

dsx3TotalUASs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds, encountered by a DS3
            interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 5 }

dsx3TotalLCVs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations encountered by a DS3/E3
            interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 6 }

dsx3TotalPCVs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of P-bit

            Coding Violations, encountered by a DS3 interface
            in the previous 24 hour interval. Invalid 15
            minute intervals count as 0."
     ::= { dsx3TotalEntry 7 }

dsx3TotalLESs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of Line Errored  Seconds  (BPVs  or
            illegal  zero  sequences) encountered by a DS3/E3
            interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 8 }

dsx3TotalCCVs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of C-bit Coding Violations encountered
            by a DS3 interface in the previous 24 hour
            interval. Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 9 }

dsx3TotalCESs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of C-bit Errored Seconds encountered
            by a DS3 interface in the previous 24 hour
            interval. Invalid 15 minute intervals count as 0."
     ::= { dsx3TotalEntry 10 }

dsx3TotalCSESs OBJECT-TYPE
     SYNTAX  PerfTotalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of C-bit Severely Errored Seconds
            encountered by a DS3 interface in the previous 24
            hour interval. Invalid 15 minute intervals count
            as 0."
     ::= { dsx3TotalEntry 11 }



-- The DS3 Far End Group

-- The DS3 Far End Group consists of four tables :
--   DS3 Far End Configuration
--   DS3 Far End Current
--   DS3 Far End Interval
--   DS3 Far End Total

-- The DS3 Far End Configuration Table

dsx3FarEndConfigTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3 Far End Configuration Table contains
            configuration information reported in the C-bits
            from the remote end."
     ::= { ds3 9 }

dsx3FarEndConfigEntry OBJECT-TYPE
     SYNTAX  Dsx3FarEndConfigEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3 Far End Configuration table."
    INDEX   { dsx3FarEndLineIndex }
     ::= { dsx3FarEndConfigTable 1 }

Dsx3FarEndConfigEntry ::=
     SEQUENCE {
        dsx3FarEndLineIndex          InterfaceIndex,
        dsx3FarEndEquipCode           DisplayString,
        dsx3FarEndLocationIDCode      DisplayString,
        dsx3FarEndFrameIDCode         DisplayString,
        dsx3FarEndUnitCode            DisplayString,
        dsx3FarEndFacilityIDCode      DisplayString
     }

dsx3FarEndLineIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the DS3
            interface to which this entry is applicable.  The
            interface identified by a particular value of this

            index is the same interface as identified by the
            same value an dsx3LineIndex object instance."
    ::= { dsx3FarEndConfigEntry 1 }

dsx3FarEndEquipCode OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (0..10))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This is the Far End Equipment Identification code
            that describes the specific piece of equipment.
            It is sent within the Path Identification
            Message."
     ::= { dsx3FarEndConfigEntry 2 }

dsx3FarEndLocationIDCode OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (0..11))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This is the Far End Location Identification code
            that describes the specific location of the
            equipment.  It is sent within the Path
            Identification Message."
     ::= { dsx3FarEndConfigEntry 3 }

dsx3FarEndFrameIDCode OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (0..10))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This is the Far End Frame Identification code
            that identifies where the equipment is located
            within a building at a given location.  It is sent
            within the Path Identification Message."
     ::= { dsx3FarEndConfigEntry 4 }

dsx3FarEndUnitCode OBJECT-TYPE
     SYNTAX  DisplayString (SIZE (0..6))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This is the Far End code that identifies the
            equipment location within a bay.  It is sent
            within the Path Identification Message."
     ::= { dsx3FarEndConfigEntry 5 }

dsx3FarEndFacilityIDCode OBJECT-TYPE

     SYNTAX  DisplayString (SIZE (0..38))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
            "This code identifies a specific Far End DS3 path.
            It is sent within the Path Identification
            Message."
     ::= { dsx3FarEndConfigEntry 6 }

-- The DS3 Far End Current

dsx3FarEndCurrentTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3FarEndCurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3 Far End Current table contains various
            statistics being collected for the current 15
            minute interval.  The statistics are collected
            from the far end block error code within the C-
            bits."
     ::= { ds3 10 }

dsx3FarEndCurrentEntry OBJECT-TYPE
     SYNTAX  Dsx3FarEndCurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3 Far End Current table."
     INDEX   { dsx3FarEndCurrentIndex }
     ::= { dsx3FarEndCurrentTable 1 }

Dsx3FarEndCurrentEntry ::=
     SEQUENCE {
         dsx3FarEndCurrentIndex        InterfaceIndex,
         dsx3FarEndTimeElapsed         INTEGER,
         dsx3FarEndValidIntervals      INTEGER,
         dsx3FarEndCurrentCESs         PerfCurrentCount,
         dsx3FarEndCurrentCSESs        PerfCurrentCount,
         dsx3FarEndCurrentCCVs         PerfCurrentCount,
         dsx3FarEndCurrentUASs         PerfCurrentCount,
         dsx3FarEndInvalidIntervals    INTEGER
    }

 dsx3FarEndCurrentIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index

     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the DS3
            interface to which this entry is applicable.  The
            interface identified by a particular value of this
            index is identical to the interface identified by
            the same value of dsx3LineIndex."
     ::= { dsx3FarEndCurrentEntry 1 }

dsx3FarEndTimeElapsed OBJECT-TYPE
     SYNTAX  INTEGER (0..899)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of seconds that have elapsed since the
            beginning of the far end current error-measurement
            period. If, for some reason, such as an adjustment
            in the system's time-of-day clock, the current
            interval exceeds the maximum value, the agent will
            return the maximum value."
     ::= { dsx3FarEndCurrentEntry 2 }

dsx3FarEndValidIntervals OBJECT-TYPE
     SYNTAX  INTEGER (0..96)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of previous far end intervals for
            which data was collected.  The value will be 96
            unless the interface was brought online within the
            last 24 hours, in which case the value will be the
            number of complete 15 minute far end intervals
            since the interface has been online. In the case
            where the agent is a proxy, it is possible that
            some intervals are unavailable.  In this case,
            this interval is the maximum interval number for
            which data is available."
     ::= { dsx3FarEndCurrentEntry 3 }

dsx3FarEndCurrentCESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Errored Seconds."
     ::= { dsx3FarEndCurrentEntry 4 }


dsx3FarEndCurrentCSESs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Severely Errored Seconds."
     ::= { dsx3FarEndCurrentEntry 5 }

dsx3FarEndCurrentCCVs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Coding Violations reported via the far end
            block error count."
     ::= { dsx3FarEndCurrentEntry 6 }

dsx3FarEndCurrentUASs OBJECT-TYPE
     SYNTAX  PerfCurrentCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            unavailable seconds."
     ::= { dsx3FarEndCurrentEntry 7 }

dsx3FarEndInvalidIntervals OBJECT-TYPE
     SYNTAX  INTEGER (0..96)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            " The number of intervals in the range from 0 to
            dsx3FarEndValidIntervals for which no data is
            available.  This object will typically be zero
            except in cases where the data for some intervals
            are not available (e.g., in proxy situations)."
     ::= { dsx3FarEndCurrentEntry 8 }

-- The DS3 Far End Interval Table

dsx3FarEndIntervalTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3FarEndIntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3 Far End Interval Table contains various

            statistics collected by each DS3 interface over
            the previous 24 hours of operation.  The past 24
            hours are broken into 96 completed 15 minute
            intervals."
     ::= { ds3 11 }

dsx3FarEndIntervalEntry OBJECT-TYPE
     SYNTAX  Dsx3FarEndIntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3 Far End Interval table."
     INDEX   { dsx3FarEndIntervalIndex,
               dsx3FarEndIntervalNumber }
     ::= { dsx3FarEndIntervalTable 1 }

Dsx3FarEndIntervalEntry ::=
     SEQUENCE {
          dsx3FarEndIntervalIndex      InterfaceIndex,
          dsx3FarEndIntervalNumber     INTEGER,
          dsx3FarEndIntervalCESs       PerfIntervalCount,
          dsx3FarEndIntervalCSESs      PerfIntervalCount,
          dsx3FarEndIntervalCCVs       PerfIntervalCount,
          dsx3FarEndIntervalUASs       PerfIntervalCount,
          dsx3FarEndIntervalValidData  TruthValue
    }

dsx3FarEndIntervalIndex OBJECT-TYPE
     SYNTAX  InterfaceIndex
     MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
     STATUS  current
     DESCRIPTION
            "The index value which uniquely identifies the DS3
            interface to which this entry is applicable.  The
            interface identified by a particular value of this
            index is identical to the interface identified by
            the same value of dsx3LineIndex."
     ::= { dsx3FarEndIntervalEntry 1 }

dsx3FarEndIntervalNumber OBJECT-TYPE
    SYNTAX  INTEGER (1..96)
    MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
    STATUS  current
    DESCRIPTION
            "A number between 1 and 96, where 1 is the most
            recently completed 15 minute interval and 96 is

            the 15 minutes interval completed 23 hours and 45
            minutes prior to interval 1."
    ::= { dsx3FarEndIntervalEntry 2 }

dsx3FarEndIntervalCESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Errored Seconds encountered by a DS3
            interface in one of the previous 96, individual 15
            minute, intervals. In the case where the agent is
            a proxy and data is not available, return
            noSuchInstance."
    ::= { dsx3FarEndIntervalEntry 3 }

dsx3FarEndIntervalCSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Severely Errored Seconds."
     ::= { dsx3FarEndIntervalEntry 4 }

dsx3FarEndIntervalCCVs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Coding Violations reported via the far end
            block error count."
     ::= { dsx3FarEndIntervalEntry 5 }

dsx3FarEndIntervalUASs OBJECT-TYPE
     SYNTAX  PerfIntervalCount
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The counter associated with the number of Far End
            unavailable seconds."
     ::= { dsx3FarEndIntervalEntry 6 }

dsx3FarEndIntervalValidData OBJECT-TYPE
     SYNTAX  TruthValue
     MAX-ACCESS  read-only

     STATUS  current
     DESCRIPTION
            " This variable indicates if the data for this
            interval is valid."
     ::= { dsx3FarEndIntervalEntry 7 }

-- The DS3 Far End Total

dsx3FarEndTotalTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF Dsx3FarEndTotalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "The DS3 Far End Total Table contains the
            cumulative sum of the various statistics for the
            24 hour period preceding the current interval."
     ::= { ds3 12 }

dsx3FarEndTotalEntry OBJECT-TYPE
     SYNTAX  Dsx3FarEndTotalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
            "An entry in the DS3 Far End Total table."
     INDEX   { dsx3FarEndTotalIndex }
     ::= { dsx3FarEndTotalTable 1 }

Dsx3FarEndTotalEntry ::=
     SEQUENCE {
         dsx3FarEndTotalIndex       InterfaceIndex,
         dsx3FarEndTotalCESs        PerfTotalCount,
         dsx3FarEndTotalCSESs       PerfTotalCount,
         dsx3FarEndTotalCCVs        PerfTotalCount,
         dsx3FarEndTotalUASs        PerfTotalCount
     }

dsx3FarEndTotalIndex OBJECT-TYPE
    SYNTAX  InterfaceIndex
    MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
    STATUS  current
    DESCRIPTION
            "The index value which uniquely identifies the DS3
            interface to which this entry is applicable.  The
            interface identified by a particular value of this
            index is identical to the interface identified by
            the same value of dsx3LineIndex."
    ::= { dsx3FarEndTotalEntry 1 }

dsx3FarEndTotalCESs OBJECT-TYPE
    SYNTAX  PerfTotalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Errored Seconds encountered by a DS3
            interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
    ::= { dsx3FarEndTotalEntry 2 }

dsx3FarEndTotalCSESs OBJECT-TYPE
    SYNTAX  PerfTotalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Severely Errored Seconds encountered by a
            DS3 interface in the previous 24 hour interval.
            Invalid 15 minute intervals count as 0."
    ::= { dsx3FarEndTotalEntry 3 }

dsx3FarEndTotalCCVs OBJECT-TYPE
    SYNTAX  PerfTotalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            C-bit Coding Violations reported via the far end
            block error count encountered by a DS3 interface
            in the previous 24 hour interval. Invalid 15
            minute intervals count as 0."
    ::= { dsx3FarEndTotalEntry 4 }

dsx3FarEndTotalUASs OBJECT-TYPE
    SYNTAX  PerfTotalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Far End
            unavailable seconds encountered by a DS3 interface
            in the previous 24 hour interval.  Invalid 15
            minute intervals count as 0."
    ::= { dsx3FarEndTotalEntry 5 }

-- the DS3/E3 Fractional Table

-- This table is deprecated.

dsx3FracTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FracEntry
    MAX-ACCESS  not-accessible
    STATUS  deprecated
    DESCRIPTION
            "This table is deprecated in favour of using
            ifStackTable.

            Implementation of this table was optional.  It was
            designed for those systems dividing a DS3/E3 into
            channels containing different data streams that
            are of local interest.

            The DS3/E3 fractional table identifies which
            DS3/E3 channels associated with a CSU are being
            used to support a logical interface, i.e., an
            entry in the interfaces table from the Internet-
            standard MIB.

            For example, consider a DS3 device with 4 high
            speed links carrying router traffic, a feed for
            voice, a feed for video, and a synchronous channel
            for a non-routed protocol.  We might describe the
            allocation of channels, in the dsx3FracTable, as
            follows:
            dsx3FracIfIndex.2. 1 = 3  dsx3FracIfIndex.2.15 = 4
            dsx3FracIfIndex.2. 2 = 3  dsx3FracIfIndex.2.16 = 6
            dsx3FracIfIndex.2. 3 = 3  dsx3FracIfIndex.2.17 = 6
            dsx3FracIfIndex.2. 4 = 3  dsx3FracIfIndex.2.18 = 6
            dsx3FracIfIndex.2. 5 = 3  dsx3FracIfIndex.2.19 = 6
            dsx3FracIfIndex.2. 6 = 3  dsx3FracIfIndex.2.20 = 6
            dsx3FracIfIndex.2. 7 = 4  dsx3FracIfIndex.2.21 = 6
            dsx3FracIfIndex.2. 8 = 4  dsx3FracIfIndex.2.22 = 6
            dsx3FracIfIndex.2. 9 = 4  dsx3FracIfIndex.2.23 = 6
            dsx3FracIfIndex.2.10 = 4  dsx3FracIfIndex.2.24 = 6
            dsx3FracIfIndex.2.11 = 4  dsx3FracIfIndex.2.25 = 6
            dsx3FracIfIndex.2.12 = 5  dsx3FracIfIndex.2.26 = 6
            dsx3FracIfIndex.2.13 = 5  dsx3FracIfIndex.2.27 = 6
            dsx3FracIfIndex.2.14 = 5  dsx3FracIfIndex.2.28 = 6
            For dsx3M23, dsx3 SYNTRAN, dsx3CbitParity, and
            dsx3ClearChannel  there are 28 legal channels,
            numbered 1 through 28.

            For e3Framed there are 16 legal channels, numbered
            1 through 16.  The channels (1..16) correspond
            directly to the equivalently numbered time-slots."
     ::= { ds3 13 }


dsx3FracEntry OBJECT-TYPE
     SYNTAX  Dsx3FracEntry
     MAX-ACCESS  not-accessible
     STATUS  deprecated
     DESCRIPTION
                    "An entry in the DS3 Fractional table."
    INDEX   { dsx3FracIndex, dsx3FracNumber }
    ::= { dsx3FracTable 1 }

Dsx3FracEntry ::=
     SEQUENCE {
         dsx3FracIndex     INTEGER,
         dsx3FracNumber    INTEGER,
         dsx3FracIfIndex   INTEGER
    }

dsx3FracIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..'7fffffff'h)
    MAX-ACCESS  read-only -- read-only since originally an
                              -- SMIv1 index
    STATUS  deprecated
    DESCRIPTION
            "The index value which uniquely identifies  the
            DS3  interface  to which this entry is applicable
            The interface identified by a  particular value
            of  this  index is the same interface as
            identified by the same value  an  dsx3LineIndex
            object instance."
    ::= { dsx3FracEntry 1 }

dsx3FracNumber OBJECT-TYPE
    SYNTAX  INTEGER (1..31)
    MAX-ACCESS  read-only  -- read-only since originally an
                            -- SMIv1 index
    STATUS  deprecated
    DESCRIPTION
            "The channel number for this entry."
   ::= { dsx3FracEntry 2 }

dsx3FracIfIndex OBJECT-TYPE
   SYNTAX  INTEGER (0..'7fffffff'h)
   MAX-ACCESS  read-write
   STATUS  deprecated
   DESCRIPTION
           "An index value that uniquely identifies an
           interface.  The interface identified by a
           particular value of this index is the same
           interface as  identified by the same value an

           ifIndex object instance. If no interface is
           currently using a channel, the value should be
           zero.  If a single interface occupies more  than
           one  time slot,  that ifIndex value will be found
           in multiple time slots."
   ::= { dsx3FracEntry 3 }

 -- DS3 TRAPS

ds3Traps OBJECT IDENTIFIER ::= { ds3 15 }

dsx3LineStatusChange NOTIFICATION-TYPE
    OBJECTS { dsx3LineStatus,
              dsx3LineStatusLastChange }
    STATUS  current
    DESCRIPTION
            "A dsx3LineStatusChange trap is sent when the
            value of an instance of dsx3LineStatus changes. It
            can be utilized by an NMS to trigger polls.  When
            the line status change results in a lower level
            line status change (i.e., ds1), then no traps for
            the lower level are sent."
     ::= { ds3Traps 0 1 }

-- conformance information

ds3Conformance OBJECT IDENTIFIER ::= { ds3 14 }
ds3Groups      OBJECT IDENTIFIER ::= { ds3Conformance 1 }
ds3Compliances OBJECT IDENTIFIER ::= { ds3Conformance 2 }

-- compliance statements

ds3Compliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for DS3/E3 interfaces."
    MODULE  -- this module
        MANDATORY-GROUPS { ds3NearEndConfigGroup,
                           ds3NearEndStatisticsGroup }

        GROUP       ds3FarEndGroup
        DESCRIPTION
            "Implementation of this group is optional for all
            systems that attach to a DS3 Interface.  However,
            only C-bit Parity and SYNTRAN DS3 applications
            have the capability (option) of providing this
            information."
        GROUP       ds3NearEndOptionalTrapGroup

        DESCRIPTION
            "Implementation of this group is optional for all
            systems that attach to a DS3 Interface.  If it is
            implemented then ds3NearEndOptionalConfigGroup
            should also be implemented."
        GROUP       ds3NearEndOptionalConfigGroup
        DESCRIPTION
            "Implementation of this group is optional for all
            systems that attach to a DS3 interface."

        OBJECT      dsx3LineType
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the line type is not required."

        OBJECT      dsx3LineCoding
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the line coding is not
            required."

        OBJECT      dsx3SendCode
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the send code is not required."

        OBJECT      dsx3LoopbackConfig
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for loopbacks is not required."

        OBJECT      dsx3TransmitClockSource
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the transmit clock source is not
            required."

        OBJECT      dsx3LineLength
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the line length is not
            required."

        OBJECT      dsx3Channelization
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access for the channelization is not
            required."

    ::= { ds3Compliances 1 }

-- units of conformance

ds3NearEndConfigGroup  OBJECT-GROUP
    OBJECTS { dsx3LineIndex,
              dsx3TimeElapsed,
              dsx3ValidIntervals,
              dsx3LineType,
              dsx3LineCoding,
              dsx3SendCode,
              dsx3CircuitIdentifier,
              dsx3LoopbackConfig,
              dsx3LineStatus,
              dsx3TransmitClockSource,
              dsx3InvalidIntervals,
              dsx3LineLength,
              dsx3LoopbackStatus,
              dsx3Channelization,
              dsx3Ds1ForRemoteLoop}
    STATUS  current
    DESCRIPTION
            "A collection of objects providing configuration
            information applicable to all DS3/E3 interfaces."
    ::= { ds3Groups 1 }

ds3NearEndStatisticsGroup OBJECT-GROUP
    OBJECTS { dsx3CurrentIndex,
              dsx3CurrentPESs,
              dsx3CurrentPSESs,
              dsx3CurrentSEFSs,
              dsx3CurrentUASs,
              dsx3CurrentLCVs,
              dsx3CurrentPCVs,
              dsx3CurrentLESs,
              dsx3CurrentCCVs,
              dsx3CurrentCESs,
              dsx3CurrentCSESs,
              dsx3IntervalIndex,
              dsx3IntervalNumber,
              dsx3IntervalPESs,
              dsx3IntervalPSESs,
              dsx3IntervalSEFSs,
              dsx3IntervalUASs,
              dsx3IntervalLCVs,
              dsx3IntervalPCVs,
              dsx3IntervalLESs,
              dsx3IntervalCCVs,

              dsx3IntervalCESs,
              dsx3IntervalCSESs,
              dsx3IntervalValidData,
              dsx3TotalIndex,
              dsx3TotalPESs,
              dsx3TotalPSESs,
              dsx3TotalSEFSs,
              dsx3TotalUASs,
              dsx3TotalLCVs,
              dsx3TotalPCVs,
              dsx3TotalLESs,
              dsx3TotalCCVs,
              dsx3TotalCESs,
              dsx3TotalCSESs }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing statistics
            information applicable to all DS3/E3 interfaces."
    ::= { ds3Groups 2 }

ds3FarEndGroup  OBJECT-GROUP
    OBJECTS { dsx3FarEndLineIndex,
              dsx3FarEndEquipCode,
              dsx3FarEndLocationIDCode,
              dsx3FarEndFrameIDCode,
              dsx3FarEndUnitCode,
              dsx3FarEndFacilityIDCode,
              dsx3FarEndCurrentIndex,
              dsx3FarEndTimeElapsed,
              dsx3FarEndValidIntervals,
              dsx3FarEndCurrentCESs,
              dsx3FarEndCurrentCSESs,
              dsx3FarEndCurrentCCVs,
              dsx3FarEndCurrentUASs,
              dsx3FarEndInvalidIntervals,
              dsx3FarEndIntervalIndex,
              dsx3FarEndIntervalNumber,
              dsx3FarEndIntervalCESs,
              dsx3FarEndIntervalCSESs,
              dsx3FarEndIntervalCCVs,
              dsx3FarEndIntervalUASs,
              dsx3FarEndIntervalValidData,
              dsx3FarEndTotalIndex,
              dsx3FarEndTotalCESs,
              dsx3FarEndTotalCSESs,
              dsx3FarEndTotalCCVs,
              dsx3FarEndTotalUASs }
    STATUS  current

    DESCRIPTION
            "A collection of objects providing remote
            configuration and statistics information
            applicable to C-bit Parity and SYNTRAN DS3
            interfaces."
    ::= { ds3Groups 3 }

ds3DeprecatedGroup OBJECT-GROUP

    OBJECTS { dsx3IfIndex,
              dsx3FracIndex,
              dsx3FracNumber,
              dsx3FracIfIndex }
    STATUS  deprecated
    DESCRIPTION
            "A collection of obsolete objects that may be
            implemented for backwards compatibility."
    ::= { ds3Groups 4 }

ds3NearEndOptionalConfigGroup OBJECT-GROUP
    OBJECTS { dsx3LineStatusLastChange,
              dsx3LineStatusChangeTrapEnable }

    STATUS    current
    DESCRIPTION
            "A collection of objects that may be implemented
            on DS3/E3 interfaces."
    ::= { ds3Groups 5 }

ds3NearEndOptionalTrapGroup NOTIFICATION-GROUP
    NOTIFICATIONS { dsx3LineStatusChange }
    STATUS    current
    DESCRIPTION
            "A collection of notifications that may be
            implemented on DS3/E3 interfaces."
    ::= { ds3Groups 6 }

END