The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing POWER-ETHERNET-MIB.
Vendor: | RFC |
---|---|
Mib: | POWER-ETHERNET-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- WinAgents MIB Extraction Wizard -- Extracted from rfc3621.txt 16.03.2005 20:22:00 POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32, Gauge32, Counter32, NOTIFICATION-TYPE FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB; powerEthernetMIB MODULE-IDENTITY LAST-UPDATED "200311240000Z" -- November 24, 2003 ORGANIZATION "IETF Ethernet Interfaces and Hub MIB Working Group" CONTACT-INFO " WG Charter: http://www.ietf.org/html.charters/hubmib-charter.html Mailing lists: General Discussion: hubmib@ietf.org To Subscribe: hubmib-requests@ietf.org In Body: subscribe your_email_address Chair: Dan Romascanu Avaya Tel: +972-3-645-8414 Email: dromasca@avaya.com Editor: Avi Berger PowerDsine Inc. Tel: 972-9-7755100 Ext 307 Fax: 972-9-7755120 E-mail: avib@PowerDsine.com " DESCRIPTION "The MIB module for managing Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following terms are used throughout this MIB module. For complete formal definitions, the IEEE 802.3 standards should be consulted wherever possible: Group - A recommended, but optional, entity defined by the IEEE 802.3 management standard, in order to support a modular numbering scheme. The classical example allows an implementor to represent field-replaceable units as groups of ports, with the port numbering matching the modular hardware implementation. Port - This entity identifies the port within the group for which this entry contains information. The numbering scheme for ports is implementation specific. Copyright (c) The Internet Society (2003). This version of this MIB module is part of RFC 3621; See the RFC itself for full legal notices." REVISION "200311240000Z" -- November 24, 2003 DESCRIPTION "Initial version, published as RFC 3621." ::= { mib-2 105 } pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 } pethObjects OBJECT IDENTIFIER ::= { powerEthernetMIB 1 } pethConformance OBJECT IDENTIFIER ::= { powerEthernetMIB 2 } -- PSE Objects pethPsePortTable OBJECT-TYPE SYNTAX SEQUENCE OF PethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethObjects 1 } pethPsePortEntry OBJECT-TYPE SYNTAX PethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the power characteristics of a power Ethernet PSE port." INDEX { pethPsePortGroupIndex , pethPsePortIndex } ::= { pethPsePortTable 1 } PethPsePortEntry ::= SEQUENCE { pethPsePortGroupIndex Integer32, pethPsePortIndex Integer32, pethPsePortAdminEnable TruthValue, pethPsePortPowerPairsControlAbility TruthValue, pethPsePortPowerPairs INTEGER, pethPsePortDetectionStatus INTEGER, pethPsePortPowerPriority INTEGER, pethPsePortMPSAbsentCounter Counter32, pethPsePortType SnmpAdminString, pethPsePortPowerClassifications INTEGER, pethPsePortInvalidSignatureCounter Counter32, pethPsePortPowerDeniedCounter Counter32, pethPsePortOverLoadCounter Counter32, pethPsePortShortCounter Counter32 } pethPsePortGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack." ::= { pethPsePortEntry 1 } pethPsePortIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected." ::= { pethPsePortEntry 2 } pethPsePortAdminEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "true (1) An interface which can provide the PSE functions. false(2) The interface will act as it would if it had no PSE function." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState" ::= { pethPsePortEntry 3 } pethPsePortPowerPairsControlAbility OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capability to control the power pairs. When false the PSE Pinout Alternative used cannot be controlled through the PethPsePortAdminEnable attribute." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.3 aPSEPowerPairsControlAbility" ::= { pethPsePortEntry 4 } pethPsePortPowerPairs OBJECT-TYPE SYNTAX INTEGER { signal(1), spare(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs" ::= { pethPsePortEntry 5 } pethPsePortDetectionStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of deliveringPower(3) - indicates that the PSE State diagram is in the state POWER_ON for a duration greater than tlim max (see IEEE Std 802.3af Table 33-5 tlim). A value of fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR. A value of test(5) - indicates that the PSE State diagram is in the state TEST_MODE. A value of otherFault(6) - indicates that the PSE State diagram is in the state IDLE due to the variable error_conditions. A value of searching(2)- indicates the PSE State diagram is in a state other than those listed above." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.5 aPSEPowerDetectionStatus" ::= { pethPsePortEntry 6 } pethPsePortPowerPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority." ::= { pethPsePortEntry 7 } pethPsePortMPSAbsentCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpdo_timer_done being asserted." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.11 aPSEMPSAbsentCounter" ::= { pethPsePortEntry 8 } pethPsePortType OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "A manager will set the value of this variable to indicate the type of powered device that is connected to the port. The default value supplied by the agent if no value has ever been set should be a zero-length octet string." ::= { pethPsePortEntry 9 } pethPsePortPowerClassifications OBJECT-TYPE SYNTAX INTEGER { class0(1), class1(2), class2(3), class3(4), class4(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The meaning of the classification labels is defined in the IEEE specification. This variable is valid only while a PD is being powered, that is, while the attribute pethPsePortDetectionStatus is reporting the enumeration deliveringPower." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.6 aPSEPowerClassification" ::= { pethPsePortEntry 10 } pethPsePortInvalidSignatureCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.7 aPSEInvalidSignatureCounter" ::= { pethPsePortEntry 11 } pethPsePortPowerDeniedCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram enters the state POWER_DENIED." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.8 aPSEPowerDeniedCounter" ::= { pethPsePortEntry 12 } pethPsePortOverLoadCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.9 aPSEOverLoadCounter" ::= { pethPsePortEntry 13 } pethPsePortShortCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_SHORT." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.10 aPSEShortCounter" ::= { pethPsePortEntry 14 } -- Main PSE Objects pethMainPseObjects OBJECT IDENTIFIER ::= { pethObjects 3 } pethMainPseTable OBJECT-TYPE SYNTAX SEQUENCE OF PethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support these objects. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethMainPseObjects 1 } pethMainPseEntry OBJECT-TYPE SYNTAX PethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the Main power of a PSE. " INDEX { pethMainPseGroupIndex } ::= { pethMainPseTable 1 } PethMainPseEntry ::= SEQUENCE { pethMainPseGroupIndex Integer32, pethMainPsePower Gauge32 , pethMainPseOperStatus INTEGER, pethMainPseConsumptionPower Gauge32, pethMainPseUsageThreshold Integer32 } pethMainPseGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack." ::= { pethMainPseEntry 1 } pethMainPsePower OBJECT-TYPE SYNTAX Gauge32 (1..65535) UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal power of the PSE expressed in Watts." ::= { pethMainPseEntry 2 } pethMainPseOperStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), faulty(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of the main PSE." ::= { pethMainPseEntry 3 } pethMainPseConsumptionPower OBJECT-TYPE SYNTAX Gauge32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "Measured usage power expressed in Watts." ::= { pethMainPseEntry 4 } pethMainPseUsageThreshold OBJECT-TYPE SYNTAX Integer32 (1..99) UNITS "%" MAX-ACCESS read-write STATUS current DESCRIPTION "The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded." ::= { pethMainPseEntry 5 } -- Notification Control Objects pethNotificationControl OBJECT IDENTIFIER ::= { pethObjects 4 } pethNotificationControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PethNotificationControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the Notification on a PSE device. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethNotificationControl 1 } pethNotificationControlEntry OBJECT-TYPE SYNTAX PethNotificationControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that control the Notification events." INDEX { pethNotificationControlGroupIndex } ::= { pethNotificationControlTable 1 } PethNotificationControlEntry ::= SEQUENCE { pethNotificationControlGroupIndex Integer32, pethNotificationControlEnable TruthValue } pethNotificationControlGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethMainPseGroupIndex to refer to a given box in a stack or module in a rack. " ::= { pethNotificationControlEntry 1 } pethNotificationControlEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls, on a per-group basis, whether or not notifications from the agent are enabled. The value true(1) means that notifications are enabled; the value false(2) means that they are not." ::= { pethNotificationControlEntry 2 } -- -- Notifications Section -- -- pethPsePortOnOffNotification NOTIFICATION-TYPE OBJECTS { pethPsePortDetectionStatus } STATUS current DESCRIPTION " This Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching mode. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= { pethNotifications 1 } pethMainPowerUsageOnNotification NOTIFICATION-TYPE OBJECTS { pethMainPseConsumptionPower } STATUS current DESCRIPTION " This Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= { pethNotifications 2 } pethMainPowerUsageOffNotification NOTIFICATION-TYPE OBJECTS { pethMainPseConsumptionPower } STATUS current DESCRIPTION " This Notification indicates PSE Threshold usage indication off, the usage power is below the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= { pethNotifications 3 } -- -- Conformance Section -- pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 } pethGroups OBJECT IDENTIFIER ::= { pethConformance 2 } pethCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the Power Ethernet MIB." MODULE -- this module MANDATORY-GROUPS { pethPsePortGroup, pethPsePortNotificationGroup, pethNotificationControlGroup } GROUP pethMainPseGroup DESCRIPTION "The pethMainPseGroup is mandatory for PSE systems that implement a main power supply." GROUP pethMainPowerNotificationGroup DESCRIPTION "The pethMainPowerNotificationGroup is mandatory for PSE systems that implement a main power supply." ::= { pethCompliances 1 } pethPsePortGroup OBJECT-GROUP OBJECTS { pethPsePortAdminEnable, pethPsePortPowerPairsControlAbility, pethPsePortPowerPairs, pethPsePortDetectionStatus, pethPsePortPowerPriority, pethPsePortMPSAbsentCounter, pethPsePortInvalidSignatureCounter, pethPsePortPowerDeniedCounter, pethPsePortOverLoadCounter, pethPsePortShortCounter, pethPsePortType, pethPsePortPowerClassifications } STATUS current DESCRIPTION "PSE Port objects." ::= { pethGroups 1 } pethMainPseGroup OBJECT-GROUP OBJECTS { pethMainPsePower, pethMainPseOperStatus, pethMainPseConsumptionPower, pethMainPseUsageThreshold } STATUS current DESCRIPTION "Main PSE Objects. " ::= { pethGroups 2 } pethNotificationControlGroup OBJECT-GROUP OBJECTS { pethNotificationControlEnable } STATUS current DESCRIPTION "Notification Control Objects. " ::= { pethGroups 3 } pethPsePortNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { pethPsePortOnOffNotification} STATUS current DESCRIPTION "Pse Port Notifications." ::= { pethGroups 4 } pethMainPowerNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { pethMainPowerUsageOnNotification, pethMainPowerUsageOffNotification} STATUS current DESCRIPTION "Main PSE Notifications." ::= { pethGroups 5 } END