AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » RFC » RFC1230-MIB

RFC1230-MIB device MIB details by RFC

RFC1230-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing RFC1230-MIB.


Vendor: RFC
Mib: RFC1230-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- WinAgents MIB Extraction Wizard
-- Extracted from rfc1230.txt 16.03.2005 20:20:14

RFC1230-MIB DEFINITIONS ::= BEGIN

--                 IEEE 802.4 Token Bus MIB

IMPORTS
        experimental, Counter
                FROM RFC1155-SMI
        OBJECT-TYPE
                FROM RFC-1212;

--  This MIB Module uses the extended OBJECT-TYPE macro as
--  defined in [9].



dot4    OBJECT IDENTIFIER ::= { experimental 7 }

-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:

MacAddress ::= OCTET STRING (SIZE (6))    -- a 6 octet
                                          -- address in the
                                          -- "canonical" order

                                          -- defined by IEEE
                                          -- 802.1a.
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.


-- This specification follows the 802.4 convention of
-- specifying time intervals, which are dependent on the
-- bandwidth of the media, in units of octet time.  One
-- octet time is the time taken to transmit eight bits.
-- Representation of such time intervals in this MIB Module
-- use, as a textual convention (i.e., this convention does
-- not affect their encoding), the data type:

OctetTime  ::= INTEGER        -- the value of a time
                              -- interval in units of octet
                              -- time.


-- The 802.4 Operational Table

-- This table contains state and parameter information which
-- is specific to 802.4 interfaces.  It is mandatory that
-- systems having 802.4 interfaces implement this table in
-- addition to the generic interfaces table [4,6] and its
-- generic extensions [11].

dot4Table  OBJECT-TYPE
           SYNTAX  SEQUENCE OF Dot4Entry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "This table contains Token Bus interface
                   parameters and state variables, one entry
                   per 802.5 interface."

           ::= { dot4 1 }

dot4Entry  OBJECT-TYPE
           SYNTAX  Dot4Entry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "A list of Token Bus status and operational
                   parameter values for an 802.4 interface."
           INDEX   { dot4IfIndex }
           ::= { dot4Table 1 }

Dot4Entry  ::= SEQUENCE {
                   dot4IfIndex
                       INTEGER,
                   dot4Options
                       INTEGER,
                   dot4State
                       INTEGER,
                   dot4Commands
                       INTEGER,
                   dot4MacAddrLen
                       INTEGER,
                   dot4NextStation
                       MacAddress,
                   dot4PreviousStation
                       MacAddress,
                   dot4SlotTime
                       OctetTime,
                   dot4LastTokenRotTime
                       OctetTime,
                   dot4HiPriTokenHoldTime
                       OctetTime,
                   dot4TargetRotTimeClass4
                       OctetTime,
                   dot4TargetRotTimeClass2
                       OctetTime,
                   dot4TargetRotTimeClass0
                       OctetTime,
                   dot4TargetRotTimeRingMaint
                       OctetTime,
                   dot4RingMaintTimerInitValue
                       OctetTime,
                   dot4MaxInterSolicitCount
                       INTEGER (16..255),
                   dot4MaxRetries
                       INTEGER (0..7),
                   dot4MinPostSilencePreambLen
                       INTEGER,
                   dot4StandardRevision
                       INTEGER
               }


dot4IfIndex  OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The value of this object identifies the

                   802.4 interface for which this entry
                   contains management information.  The
                   value of this object for a particular
                   interface has the same value as the
                   ifIndex object, defined in [4,6], for the
                   same interface."
           ::= { dot4Entry 1 }

dot4Options OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The optional parts of the 802.4
                   specification which are in use by this
                   station.  The options of the 802.4
                   specification are represented by the
                   following values:
                         1 - Priority
                         2 - Request-With-Response
                   The value of this object is given by the
                   sum of the above representations for
                   those options in use on this interface.
                   The value zero indicates that no options
                   are in use."
           ::= { dot4Entry 2 }

dot4State OBJECT-TYPE
           SYNTAX  INTEGER {
                       other(1),
                       offline(2),
                       outOfRing(3),
                       enteringRing(4),
                       inRing(5)
                   }
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The current state of the 802.4
                   interface.  The value of other(1) is
                   used if the state is unknown
                   (e.g., due to an error condition)."
           ::=   { dot4Entry 3 }

dot4Commands OBJECT-TYPE
           SYNTAX  INTEGER {
                       no-op(1),
                       enterRing(2),

                       exitRing(3),
                       reset(4),
                       initialize(5)
                   }
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "Setting this object causes the station
                   to change the state of the interface as
                   indicated by the specified value.  An
                   initialize(5) command causes the
                   interfaceto load its operational
                   parameters from its initialization
                   parameters; the value of
                   dot4InitInRingDesired determines
                   whether the station tries to enter the
                   logical ring immediately.
                       Note that the 802.4 specification
                   suggests a station remain Offline after a
                   'remote Network Management' reset(4),
                   until a 'local Network Management'
                   initialize(5) is performed.
                       Setting this object to a value of
                   no-op(1) has no effect.  When read,
                   this object always has the value no-op(1)."
           ::=  { dot4Entry 4 }

dot4MacAddrLen OBJECT-TYPE
           SYNTAX  INTEGER {
                       sixteenBit(1),
                       forty-eightBit(2)
                   }
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "This object indicates the size of MAC
                   addresses interpreted by this station."
           ::= { dot4Entry 5 }

dot4NextStation OBJECT-TYPE
           SYNTAX  MacAddress
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The MAC address of this station's
                   successor in the logical ring."
           ::= { dot4Entry 6 }


dot4PreviousStation OBJECT-TYPE
           SYNTAX  MacAddress
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The source MAC address of the last token
                   addressed to this station."
           ::= { dot4Entry 7 }

dot4SlotTime OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The maximum time any station need wait
                   for an immediate MAC-level response from
                   another station.
                   This value must the same in all stations on
                   the 802.4 network."
           ::= { dot4Entry 8 }

dot4LastTokenRotTime OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The observed token rotation time for the
                   last token rotation, timed from token
                   arrival to token arrival.  A value of
                   zero indicates that the token is not
                   rotating."
           ::= { dot4Entry 9 }

dot4HiPriTokenHoldTime OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The maximum duration for which a station
                   can hold the token to transmit frames of
                   access class 6 (if the priority option is
                   implemented), or of any access class (if
                   the priority option is not implemented)."
           ::= { dot4Entry 10 }

dot4TargetRotTimeClass4 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only

           STATUS  mandatory
           DESCRIPTION
                   "If the priority scheme is being used,
                   this value specifies a limit on how long
                   a station can transmit frames at access
                   class 4.  The limit is measured from the
                   time the station is able to start
                   transmitting frames at this access class
                   on one rotation, to the time it must stop
                   transmitting frames at this access class
                   on the next rotation.  If the priority
                   scheme is not being used, this object has
                   the value 0."
           ::= { dot4Entry 11 }

dot4TargetRotTimeClass2 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "If the priority scheme is being used,
                   this value specifies a limit on how long
                   a station can transmit frames at access
                   class 2.  The limit is measured from the
                   time the station is able to start
                   transmitting frames at this access
                   class on one rotation, to the time it
                   must stop transmitting frames at this
                   access class on the next rotation.  If
                   the priority scheme is not being used,
                   this object has the value 0."
           ::= { dot4Entry 12 }

dot4TargetRotTimeClass0 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "If the priority scheme is being used,
                   this value specifies a limit on how long
                   a station can transmit frames at access
                   class 0.  The limit is measured from the
                   time the station is able to start
                   transmitting frames at this access
                   class on one rotation, to the time it
                   must stop transmitting frames at this
                   access class on the next rotation.  If
                   the priority scheme is not being used,

                   this object has the value 0."
           ::= { dot4Entry 13 }

dot4TargetRotTimeRingMaint OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "A value used to limit the duration of a
                   token rotation.  If the duration of a
                   token rotation exceeds this value, the
                   station will not open the response window
                   to solicit for a new successor."
           ::= { dot4Entry 14 }

dot4RingMaintTimerInitValue OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The value to which the
                   dot4TargetRotTimeRingMaint is set, each
                   time the station enters the ring.
                   A large value will cause the station to
                   solicit successors immediately upon entry
                   to the ring; a value of zero will cause
                   the station to defer this solicitation
                   for at least one token rotation."
           ::= { dot4Entry 15 }

dot4MaxInterSolicitCount OBJECT-TYPE
           SYNTAX  INTEGER (16..255)
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The maximum number of consecutive token
                   rotations without soliciting for a
                   successor.  If this count expires, the
                   station opens the response window to
                   solicit for a successor (providing the
                   duration of the current token rotation
                   has not exceeded
                   dot4TargetRotTimeRingMaint).  The least
                   significant two bits of the count are
                   determined randomly by the station on a
                   per-use basis."
           ::= { dot4Entry 16 }


dot4MaxRetries OBJECT-TYPE
           SYNTAX  INTEGER (0..7)
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The maximum number of retries of a
                   Request-with-Response (RWR) frame.  If
                   the RWR option is not in use, this object
                   has the value 0."
           ::= { dot4Entry 17 }

dot4MinPostSilencePreambLen OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The minimum number of octets of preamble
                   on the first frame transmitted by this
                   station after a period of 'transmitted'
                   silence."
           ::= { dot4Entry 18 }

dot4StandardRevision OBJECT-TYPE
           SYNTAX  INTEGER {
                       rev2(2)
                   }
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The Revision number of the 802.4 standard
                   implemented by this station."
           ::= { dot4Entry 19 }


-- 802.4 Initialization Table

-- This table contains the parameter information used by an
-- 802.4 interface as the values to be assigned to its
-- operational parameters upon initialization.  It is
-- mandatory that systems having 802.4 interfaces implement
-- this table.

dot4InitTable  OBJECT-TYPE
           SYNTAX  SEQUENCE OF Dot4InitEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "This table contains Token Bus

                   initialization parameters, one entry per
                   802.4 interface."
           ::= { dot4 2 }

dot4InitEntry  OBJECT-TYPE
           SYNTAX  Dot4InitEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "A list of Token Bus initialization
                   parameters for an 802.4 interface."
           INDEX   { dot4InitIfIndex }
           ::= { dot4InitTable 1 }

Dot4InitEntry ::= SEQUENCE {
                      dot4InitIfIndex
                          INTEGER,
                      dot4InitSlotTime
                          OctetTime,
                      dot4InitMaxInterSolicitCount
                          INTEGER (16..255),
                      dot4InitMaxRetries
                          INTEGER (0..7),
                      dot4InitHiPriTokenHoldTime
                          OctetTime,
                      dot4InitTargetRotTimeClass4
                          OctetTime,
                      dot4InitTargetRotTimeClass2
                          OctetTime,
                      dot4InitTargetRotTimeClass0
                          OctetTime,
                      dot4InitTargetRotTimeRingMaint
                          OctetTime,
                      dot4InitRingMaintTimerInitValue
                          OctetTime,
                      dot4InitMinPostSilencePreambLen
                          INTEGER,
                      dot4InitInRingDesired
                          INTEGER
                  }

dot4InitIfIndex  OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The value of this object identifies the
                   802.4 interface for which this entry

                   contains management information.  The
                   value of this object for a particular
                   interface has the same value as the
                   ifIndex object, defined in [4,6], for
                   the same interface."
           ::= { dot4InitEntry 1 }

dot4InitSlotTime OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4SlotTime when the station is
                   initialized."
           ::= { dot4InitEntry 2 }

dot4InitMaxInterSolicitCount OBJECT-TYPE
           SYNTAX  INTEGER (16..255)
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4MaxInterSolicitCount when the station
                   is initialized."
           ::= { dot4InitEntry 3 }

dot4InitMaxRetries OBJECT-TYPE
           SYNTAX  INTEGER (0..7)
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4MaxRetries when the station is
                   initialized."
           ::= { dot4InitEntry 4 }

dot4InitHiPriTokenHoldTime OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4HiPriTokenHoldTime when the station
                   is initialized."
           ::= { dot4InitEntry 5 }



dot4InitTargetRotTimeClass4 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4TargetRotTimeClass4 when the station
                   is initialized."
           ::= { dot4InitEntry 6 }

dot4InitTargetRotTimeClass2 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4TargetRotTimeClass2 when the station
                   is initialized."
           ::= { dot4InitEntry 7 }

dot4InitTargetRotTimeClass0 OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4TargetRotTimeClass0 when the station
                   is initialized."
           ::= { dot4InitEntry 8 }

dot4InitTargetRotTimeRingMaint OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4TargetRotTimeRingMaint when the station
                   is initialized."
           ::= { dot4InitEntry 9 }

dot4InitRingMaintTimerInitValue OBJECT-TYPE
           SYNTAX  OctetTime
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4RingMaintTimerInitValue when the
                   station is initialized."

           ::= { dot4InitEntry 10 }

dot4InitMinPostSilencePreambLen OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "The value assigned to the object
                   dot4MinPostSilencePreambLen when the
                   station is initialized."
           ::= { dot4InitEntry 11 }

dot4InitInRingDesired OBJECT-TYPE
           SYNTAX INTEGER {
                      inRing(1),
                      outOfRing(2)
                  }
           ACCESS  read-write
           STATUS  mandatory
           DESCRIPTION
                   "This object determines whether the
                   station will attempt to enter the logical
                   ring immediately after initialization."
           ::= { dot4InitEntry 12 }


-- 802.4 Statistics Table

-- This table contains Token Bus statistics, one entry per
-- 802.4 interface.  It is mandatory that systems having
-- 802.4 interfaces implement this table.

dot4StatsTable  OBJECT-TYPE
           SYNTAX  SEQUENCE OF Dot4StatsEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "A table containing Token Bus statistics.
                   All the statistics are defined using the
                   syntax Counter as 32 bit wrap around
                   counters.  Thus, if an interface's
                   hardware chip set maintains these
                   statistics in 16-bit counters, then the
                   agent must read the hardware's counters
                   frequently enough to prevent loss of
                   significance, in order to maintain
                   a 32-bit counter in software."
           ::= { dot4 3 }

dot4StatsEntry  OBJECT-TYPE
           SYNTAX  Dot4StatsEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                   "An entry containing the 802.4 statistics
                   for a particular interface."
           INDEX   { dot4StatsIfIndex }
           ::= { dot4StatsTable 1 }

Dot4StatsEntry ::= SEQUENCE {
                        dot4StatsIfIndex
                           INTEGER,
                        dot4StatsTokenPasses
                           Counter,
                        dot4StatsTokenHeards
                           Counter,
                        dot4StatsNoSuccessors
                           Counter,
                        dot4StatsWhoFollows
                           Counter,
                        dot4StatsTokenPassFails
                           Counter,
                        dot4StatsNonSilences
                           Counter,
                        dot4StatsFcsErrors
                           Counter,
                        dot4StatsEbitErrors
                           Counter,
                        dot4StatsFrameFrags
                           Counter,
                        dot4StatsFrameTooLongs
                           Counter,
                        dot4StatsOverRuns
                           Counter,
                        dot4StatsDupAddresses
                           Counter
                   }

dot4StatsIfIndex  OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The value of this object identifies the
                   802.4 interface for which this entry
                   contains management information.  The
                   value of this object for a particular

                   interface has the same value as the
                   ifIndex object, defined in [4,6], for the
                   same interface."
           ::= { dot4StatsEntry 1 }

dot4StatsTokenPasses OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  optional
           DESCRIPTION
                   "The number of times this station has
                   passed the token."
           ::= { dot4StatsEntry 2 }

dot4StatsTokenHeards OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  optional
           DESCRIPTION
                   "The number of tokens heard by this
                   station."
           ::= { dot4StatsEntry 3 }

dot4StatsNoSuccessors OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of times the station could
                   not find a successor while believing
                   itself not the only station in the ring.
                   This can signify a faulty transmitter
                   condition in this station."
           ::= { dot4StatsEntry 4 }

dot4StatsWhoFollows OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of times the station has had
                   to look for a new next station."
           ::= { dot4StatsEntry 5 }

dot4StatsTokenPassFails OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory

           DESCRIPTION
                   "The number of times the station failed in
                   passing the token to the next station."
           ::= { dot4StatsEntry 6 }

dot4StatsNonSilences OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of occurrences of non-silence
                   followed by silence in which a start
                   delimiter was not detected."
           ::= { dot4StatsEntry 7 }

dot4StatsFcsErrors OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of frames received with an
                   incorrect FCS and the E-bit reset."
           ::= { dot4StatsEntry 8 }

dot4StatsEbitErrors OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of frames the station
                   received with the E-bit set in the
                   end delimiter."
           ::= { dot4StatsEntry 9 }

dot4StatsFrameFrags OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of occurrences of receiving a
                   start delimiter followed by another start
                   delimiter, an invalid symbol sequence or
                   silence, without an intervening end
                   delimiter."
           ::= { dot4StatsEntry 10 }

dot4StatsFrameTooLongs OBJECT-TYPE
           SYNTAX  Counter

           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of frames that were received
                   that were larger than the media's MTU."
           ::= { dot4StatsEntry 11 }

dot4StatsOverRuns OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of times a FIFO overrun was
                   detected in the station."
           ::= { dot4StatsEntry 12 }

dot4StatsDupAddresses OBJECT-TYPE
           SYNTAX  Counter
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                   "The number of times this station
                   detected another station using the same
                   MAC address."
           ::= { dot4StatsEntry 13 }


--                      802.4 Interface Tests

dot4Tests         OBJECT IDENTIFIER ::= { dot4 5 }

-- The extensions to the interfaces table proposed in [11]
-- define a table object, ifExtnsTestTable, through which a
-- network manager can instruct an agent to test an interface
-- for various faults.  A test to be performed is identified
-- (as the value of ifExtnsTestType) via an OBJECT IDENTIFIER.

-- When a test fails, the object ifExtnsTestCode, defined in
-- [11], may contain a media-specific error-code.  For 802.4
-- interfaces, the following is defined as the value of
-- ifExtnsTestCode when a test fails because the modem could
-- not be initialized:

dot4Errors OBJECT IDENTIFIER ::= { dot4 4 }
dot4ModemInitFailed OBJECT IDENTIFIER ::= { dot4Errors 1 }

-- The Full-Duplex Loop Back Test is a common test, defined
-- in [11] as:

--
--    testFullDuplexLoopBack
--
-- Invoking this test on a 802.4 interface causes the
-- interface to check the path from memory through the chip
-- set's serial interface back to memory, thus checking the
-- proper functioning of the transmit and receive machines
-- of the token bus hardware.
-- This test may only be invoked when the interface is
-- the Offline state.

-- The FIFO Path test is defined by:

testFifoPath   OBJECT IDENTIFIER ::= { dot4Tests 1 }

-- Invoking this test causes the interface to check the path
-- from memory to the chip set's FIFO and back to memory.
-- This test checks the hosts interface to the token bus
-- hardware.  This test may only be invoked when the
-- interface is the Offline state.

-- The External Loopback test is defined by:

testExternalLoopback OBJECT IDENTIFIER ::= { dot4Tests 2 }

-- Invoking this test causes the interface to check the path
-- from memory through the chip set and out onto the network
-- for external (e.g., at the head-end) loopback through the
-- chip set to memory. This test checks the host's interface
-- to the 802.4 network.  This test is liable to cause
-- serious disruption if invoked on an operational network.



--                 802.4 Hardware Chip Sets

dot4ChipSets       OBJECT IDENTIFIER ::= { dot4 6 }

-- The extensions to the interfaces table proposed in [11]
-- define an object, ifExtnsChipSet, with the syntax of
-- OBJECT IDENTIFIER, to identify the hardware chip set in
-- use by an interface.  That definition specifies just
-- one applicable object identifier:
--
--    unknownChipSet
--
-- for use as the value of ifExtnsChipSet when the specific
-- chip set is unknown.

--
-- This MIB defines the following for use as values of
-- ifExtnsChipSet:
-- for use as values of ifExtnsChipSet

   -- Motorola 68824 Token Bus Controller
chipSetMc68824  OBJECT IDENTIFIER ::= { dot4ChipSets 1 }

END