The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ROHC-RTP-MIB.
Vendor: | RFC |
---|---|
Mib: | ROHC-RTP-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- WinAgents MIB Extraction Wizard -- Extracted from rfc3816.txt 16.03.2005 20:22:03 ROHC-RTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32, mib-2 FROM SNMPv2-SMI -- [RFC2578] TruthValue FROM SNMPv2-TC -- [RFC2579] MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- [RFC2580] rohcChannelID, rohcContextCID FROM ROHC-MIB; -- [RFC3816] rohcRtpMIB MODULE-IDENTITY LAST-UPDATED "200406030000Z" -- June 3, 2004 ORGANIZATION "IETF Robust Header Compression Working Group" CONTACT-INFO "WG charter: http://www.ietf.org/html.charters/rohc-charter.html Mailing Lists: General Discussion: rohc@ietf.org To Subscribe: rohc-request@ietf.org In Body: subscribe your_email_address Editor: Juergen Quittek NEC Europe Ltd. Network Laboratories Kurfuersten-Anlage 36 69221 Heidelberg Germany Tel: +49 6221 90511-15 EMail: quittek@netlab.nec.de" DESCRIPTION "This MIB module defines a set of objects for monitoring and configuring RObust Header Compression (ROHC). The objects are specific to ROHC RTP (profile 0x0001), ROHC UDP (profile 0x0002), and ROHC ESP (profile 0x0003) defined in RFC 3095 and for the ROHC LLA profile (profile 0x0005) defined in RFC 3242. Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3816. For full legal notices see the RFC itself or see: http://www.ietf.org/copyrights/ianamib.html" REVISION "200406030000Z" -- June 3, 2004 DESCRIPTION "Initial version, published as RFC 3816." ::= { mib-2 114 } -- -- The groups defined within this MIB module: -- rohcRtpObjects OBJECT IDENTIFIER ::= { rohcRtpMIB 1 } rohcRtpConformance OBJECT IDENTIFIER ::= { rohcRtpMIB 2 } -- -- Context Table -- -- The rohcRtpContextTable lists all contexts per interface -- and instance. It extends the rohcContextTable. -- rohcRtpContextTable OBJECT-TYPE SYNTAX SEQUENCE OF RohcRtpContextEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists and describes RTP profile specific properties of compressor contexts and decompressor contexts. It extends the rohcContextTable of the ROHC-MIB module." ::= { rohcRtpObjects 1 } rohcRtpContextEntry OBJECT-TYPE SYNTAX RohcRtpContextEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry describing a particular context." INDEX { rohcChannelID, rohcContextCID } ::= { rohcRtpContextTable 1 } RohcRtpContextEntry ::= SEQUENCE { rohcRtpContextState INTEGER, rohcRtpContextMode INTEGER, rohcRtpContextAlwaysPad TruthValue, rohcRtpContextLargePktsAllowed TruthValue, rohcRtpContextVerifyPeriod Unsigned32, rohcRtpContextSizesAllowed Unsigned32, rohcRtpContextSizesUsed Unsigned32, rohcRtpContextACKs Counter32, rohcRtpContextNACKs Counter32, rohcRtpContextSNACKs Counter32, rohcRtpContextNHPs Counter32, rohcRtpContextCSPs Counter32, rohcRtpContextCCPs Counter32, rohcRtpContextPktsLostPhysical Counter32, rohcRtpContextPktsLostPreLink Counter32 } rohcRtpContextState OBJECT-TYPE SYNTAX INTEGER { initAndRefresh(1), firstOrder(2), secondOrder(3), noContext(4), staticContext(5), fullContext(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the context as defined in RFC 3095. States initAndRefresh(1), firstOrder(2), and secondOrder(3) are states of compressor contexts, states noContext(4), staticContext(5) and fullContext(6) are states of decompressor contexts." REFERENCE "RFC 3095" ::= { rohcRtpContextEntry 3 } rohcRtpContextMode OBJECT-TYPE SYNTAX INTEGER { unidirectional(1), optimistic(2), reliable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mode of the context." REFERENCE "RFC 3095, Section 4.4" ::= { rohcRtpContextEntry 4 } rohcRtpContextAlwaysPad OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean, only applicable to compressor contexts using the LLA profile. If its value is true, the compressor must pad every RHP packet with a minimum of one octet ROHC padding. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.1" DEFVAL { false } ::= { rohcRtpContextEntry 5 } rohcRtpContextLargePktsAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean, only applicable to compressor contexts using the LLA profile. It specifies how to handle packets that do not fit any of the preferred packet sizes specified. If its value is true, the compressor must deliver the larger packet as-is and must not use segmentation. If it is set to false, the ROHC segmentation scheme must be used to split the packet into two or more segments, and each segment must further be padded to fit one of the preferred packet sizes. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.1" DEFVAL { true } ::= { rohcRtpContextEntry 6 } rohcRtpContextVerifyPeriod OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to compressor contexts using the LLA profile. It specifies the minimum frequency with which a packet validating the context must be sent. This tells the compressor that a packet containing a CRC field must be sent at least once every N packets, where N is the value of the object. A value of 0 indicates that periodical verifications are disabled. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.1" DEFVAL { 0 } ::= { rohcRtpContextEntry 7 } rohcRtpContextSizesAllowed OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is only valid for decompressor contexts, i.e., if rohcInstanceType of the corresponding rohcContextEntry has the value decompressor(2). For compressor contexts where rohcInstanceType has the value compressor(1), this object MUST NOT be instantiated. This object contains the number of different packet sizes that may be used in the context." REFERENCE "RFC 3095, Section 6.3.1" ::= { rohcRtpContextEntry 8 } rohcRtpContextSizesUsed OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is only valid for decompressor contexts, i.e., if rohcInstanceType of the corresponding rohcContextEntry has the value decompressor(2). For compressor contexts where rohcInstanceType has the value compressor(1), this object MUST NOT be instantiated. This object contains the number of different packet sizes that are used in the context." REFERENCE "RFC 3095, Section 6.3.1" ::= { rohcRtpContextEntry 9 } rohcRtpContextACKs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of all positive feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB." REFERENCE "RFC 3095, Section 5.2.1." ::= { rohcRtpContextEntry 10 } rohcRtpContextNACKs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of all dynamic negative feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB." REFERENCE "RFC 3095, Section 5.2.1." ::= { rohcRtpContextEntry 11 } rohcRtpContextSNACKs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of all static negative feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB." REFERENCE "RFC 3095, Section 5.2.1." ::= { rohcRtpContextEntry 12 } rohcRtpContextNHPs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to contexts using the LLA profile. It contains the number of all no-header packets (NHP) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 4.1.1." ::= { rohcRtpContextEntry 13 } rohcRtpContextCSPs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to contexts using the LLA profile. It contains the number of all context synchronization packets (CSP) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 4.1.2." ::= { rohcRtpContextEntry 14 } rohcRtpContextCCPs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to contexts using the LLA profile. It contains the number of all context check packets (CCP) sent or received in this context, respectively. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 4.1.3." ::= { rohcRtpContextEntry 15 } rohcRtpContextPktsLostPhysical OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to decompressor contexts using the LLA profile. It contains the number of physical packet losses on the link between compressor and decompressor, that have been indicated to the decompressor. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.2." ::= { rohcRtpContextEntry 16 } rohcRtpContextPktsLostPreLink OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to decompressor contexts using the LLA profile. It contains the number of pre-link packet losses on the link between compressor and decompressor, that have been indicated to the decompressor. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.2." ::= { rohcRtpContextEntry 17 } -- -- Packet Sizes Table -- -- The rohcPacketSizeTable lists allowed, preferred, and used -- packet sizes per compressor context. rohcRtpPacketSizeTable OBJECT-TYPE SYNTAX SEQUENCE OF RohcRtpPacketSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists all allowed, preferred, and used packet sizes per compressor context and channel. Note, that the sizes table represents implementation parameters that are suggested by RFC 3095 and/or RFC 3242, but that are not mandatory." ::= { rohcRtpObjects 2 } rohcRtpPacketSizeEntry OBJECT-TYPE SYNTAX RohcRtpPacketSizeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of a particular packet size." INDEX { rohcChannelID, rohcContextCID, rohcRtpPacketSize } ::= { rohcRtpPacketSizeTable 1 } RohcRtpPacketSizeEntry ::= SEQUENCE { rohcRtpPacketSize Unsigned32, rohcRtpPacketSizePreferred TruthValue, rohcRtpPacketSizeUsed TruthValue, rohcRtpPacketSizeRestrictedType INTEGER } rohcRtpPacketSize OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A packet size used as index." ::= { rohcRtpPacketSizeEntry 3 } rohcRtpPacketSizePreferred OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to compressor contexts using the LLA profile. When retrieved, it will have the value true(1) if the packet size is preferred. Otherwise, its value will be false(2). The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.1" ::= { rohcRtpPacketSizeEntry 4 } rohcRtpPacketSizeUsed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to compressor contexts using the UDP, RTP, or ESP profile. When retrieved, it will have the value true(1) if the packet size is used. Otherwise, its value will be false(2). The value of this object is only valid for UDP, RTP, and ESP profiles, i.e., if the corresponding rohcProfile has a value of either 0x0001, 0x0002 or 0x0003. If the corresponding rohcProfile has a value other than 0x0001, 0x0002 or 0x0003, then this object MUST NOT be instantiated." REFERENCE "RFC 3095, Section 6.3.1" ::= { rohcRtpPacketSizeEntry 5 } rohcRtpPacketSizeRestrictedType OBJECT-TYPE SYNTAX INTEGER { nhpOnly(1), rhpOnly(2), noRestrictions(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to preferred packet sizes of compressor contexts using the LLA profile. When retrieved, it will indicate whether the packet size is preferred for NHP only, for RHP only, or for both of them. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.1" ::= { rohcRtpPacketSizeEntry 6 } -- -- conformance information -- rohcRtpCompliances OBJECT IDENTIFIER ::= { rohcRtpConformance 1 } rohcRtpGroups OBJECT IDENTIFIER ::= { rohcRtpConformance 2 } -- -- compliance statements -- rohcRtpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMP entities that implement the ROHC-RTP-MIB. Note that compliance with this compliance statement requires compliance with the rohcCompliance MODULE-COMPLIANCE statement of the ROHC-MIB and with the ifCompliance3 MODULE-COMPLIANCE statement of the IF-MIB (RFC2863)." MODULE -- this module MANDATORY-GROUPS { rohcRtpContextGroup } GROUP rohcRtpPacketSizesGroup DESCRIPTION "A compliant implementation does not have to implement the rohcRtpPacketSizesGroup." GROUP rohcRtpStatisticsGroup DESCRIPTION "A compliant implementation does not have to implement the rohcRtpStatisticsGroup." ::= { rohcRtpCompliances 1 } rohcRtpContextGroup OBJECT-GROUP OBJECTS { rohcRtpContextState, rohcRtpContextMode, rohcRtpContextAlwaysPad, rohcRtpContextLargePktsAllowed, rohcRtpContextVerifyPeriod } STATUS current DESCRIPTION "A collection of objects providing information about ROHC RTP compressors and decompressors." ::= { rohcRtpGroups 1 } rohcRtpPacketSizesGroup OBJECT-GROUP OBJECTS { rohcRtpContextSizesAllowed, rohcRtpContextSizesUsed, rohcRtpPacketSizePreferred, rohcRtpPacketSizeUsed, rohcRtpPacketSizeRestrictedType } STATUS current DESCRIPTION "A collection of objects providing information about allowed and used packet sizes at a ROHC RTP compressor." ::= { rohcRtpGroups 2 } rohcRtpStatisticsGroup OBJECT-GROUP OBJECTS { rohcRtpContextACKs, rohcRtpContextNACKs, rohcRtpContextSNACKs, rohcRtpContextNHPs, rohcRtpContextCSPs, rohcRtpContextCCPs, rohcRtpContextPktsLostPhysical, rohcRtpContextPktsLostPreLink } STATUS current DESCRIPTION "A collection of objects providing ROHC compressor and decompressor statistics." ::= { rohcRtpGroups 3 } END