BASIS-GENERIC-MIB device MIB details by Stratacom
BASIS-GENERIC-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing BASIS-GENERIC-MIB.
Vendor: | Stratacom |
---|---|
Mib: | BASIS-GENERIC-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- ***************************************************************** -- BASIS Generic MIB -- -- September 2002 -- -- Copyright (c) 1996-2001, 2002 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** -- -- LAST-UPDATED "200209240000Z" -- DESCRIPTION -- "The Card Generic mib containing generic information about -- the service modules(Function Modules),back cards(Line Modules). -- This contains information such as card type, back card type, -- card status, back card status,serial number, -- hardware revision, firmware version,reset reasons etc." -- -- REVISION "200209240000Z" -- DESCRIPTION -- "Clarified the descriptions of some of the objects. -- Added transId OBJECT-TYPE. -- -- REVISION "200110150000Z" -- DESCRIPTION -- "Added following enumeration in <functionModuleType> -- vism-pr-8T1 (563) -- vism-pr-8E1 (564) -- " -- REVISION "200110020000Z" -- DESCRIPTION -- "Modified description for configChangeTypeBitMap. -- Added configChangeParentObjectIndex, -- configChangeGrandParentObjectIndex and -- configChangeSMSpecificObject in -- cardInformation Table -- " -- -- REVISION "200109240000Z" -- DESCRIPTION -- "Added following enumeration in <functionModuleType> -- cesmB-8T1 (787) -- " -- -- REVISION "200109210000Z" -- DESCRIPTION -- "Added following enumerations in <functionModuleState> -- notResponding(14) -- cardinit(17) -- " -- -- REVISION "200108230000Z" -- DESCRIPTION -- CONTACT-INFO -- " Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-wanatm@cisco.com" -- " BASIS-GENERIC-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB cardGeneric FROM BASIS-MIB; cardInformation OBJECT IDENTIFIER ::= { cardGeneric 1 } cardInterface OBJECT IDENTIFIER ::= { cardGeneric 2 } cardSelfTest OBJECT IDENTIFIER ::= { cardGeneric 3 } -- ------------------------------------------------------------------ -- -- Group "cardInformation" -- This group contains information which is generic to all cards in BASIS. -- ------------------------------------------------------------------ moduleSlotNumber OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Slot number this card is present " ::= { cardInformation 1 } -- function Module is also referred to as front card in some instances -- functionModuleType OBJECT-TYPE SYNTAX INTEGER { other (1), asc (2), bnm-T3 (10), bnm-E3 (11), bnm-155 (12), srm-4T1E1 (20), srm-3T3 (21), -- SRME srme-1OC3 (22), srme-1STS3(23), srme-NOBC(24), srm-3T3-NOBC(25), frsm-4T1 (30), frsm-4E1 (31), frsm-4T1-C(32), frsm-4E1-C(33), -- HSSI frsm-hs1 (34), frsm-8T1 (35), frsm-8E1 (36), frsm-hs1b (37), ausm-4T1 (40), ausm-4E1 (41), ausm-8T1 (50), ausm-8E1 (51), -- AUSM Model B ausmB-8T1 (52), ausmB-8E1 (53), cesm-4T1 (60), cesm-4E1 (61), imatm-T3T1 (70), imatm-E3E1 (71), -- imatm model B imatmB-8T1 (72), imatmB-8E1 (73), frasm-8T1 (80), cesm-8T1 (90), cesm-8E1 (91), -- SM from Netro bscsm-2 (100), bscsm-4 (101), -- testers atmt-8T1 (110), atmt-8E1 (111), frt-8T1 (120), frt-8E1 (121), -- frsm_vhs cards frsm-2ct3 (130), frsm-2t3 (131), frsm-2e3 (132), frsm-hs2 (133), frsm-2t3b (134), frsm-2e3b (135), frsm-hs2b-hssi (136), frsm-hs2b-12In1 (137), -- cesm_t3e3 cards cesm-T3 (140), cesm-E3 (141), -- VISM vism-8T1 (150), vism-8E1 (151), -- VISM PR vism-pr-8T1 (563), vism-pr-8E1 (564), cesmB-8T1 (787), pxm1 (1000), pxm1-2t3e3 (1001), pxm1-4oc3 (1002), pxm1-oc12 (1003), rpm (2000), rpm-pr (2001) } ACCESS read-only STATUS mandatory DESCRIPTION "This object holds the type of the card. The card can type is for Processor module as well as service module. " DEFVAL { other } ::= { cardInformation 2 } functionModuleDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the card " ::= { cardInformation 3 } functionModuleSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "Serial number of the function Module." ::= { cardInformation 4 } functionModuleHWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "Hardware revision number for function Module." ::= { cardInformation 5 } functionModuleFWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware revision number of the function Module." ::= { cardInformation 6 } functionModuleState OBJECT-TYPE SYNTAX INTEGER{ nocard (1), standby (2), active (3), failed (4), selfTest (5), heldInReset (6), boot (7), mismatch (8), unknown (9), coreCardMisMatch (10), blocked (11), reserved (12), hold (13), notResponding (14), cardinit (17) } ACCESS read-only STATUS mandatory DESCRIPTION "This object holds the status of a card in a particular shelf-slot. The possible values are : nocard(1) : card not present. standby(2) : card in standby state. The card is in ready state and will be ready to take over the service if the corresponding active card(redundant) fails. active(3) : card in active state. The card is providing the service. failed(4) : card in failed state. The card can come out of this state only after user intervention (Reset or running some CLI commands). selfTest(5) : online diagnostics is being run in card. heldInReset(6) : The card configuration is being cleared. No requests can be serviced. boot(7) : card in boot state. mismatch(8) : card is not compatible with the current configuration. Card was correctly provisioned earlier, however the card was replaced by an incompatible card. This state can be resolved by clearing the configuration, or replacing with the appropriate card. unknown(9) : could not determine the state coreCardMisMatch(10) : Controller Card(PXM/ASC etc) and SRM(Service Resource Module) combination does not match. blocked(11) : In case of 1:N redundancy configuration the secondary card(backup card) is covering one of the primary card and can not cover any other card in the group if there is a failure. Redundancy is blocked. hold(13) : The standby controller card assumes the hold state during PXM upgrades. In this state, the standby PXM will be running a different software but will be receiving all standby updates(BRAM and Database). This state is applicable only for MGX8250 Platform. notResponding(14): Response from the Service Module has become slow probably due to overloading of CPU. No recovery action is required on user part. At present, this state is applicable only for Router Blade(RPM). cardinit(17) : When the physical presence of card has been detected but the communication hasn't yet been established between the controller card (PXM) and Service Module. " ::= { cardInformation 7 } functionModuleResetReason OBJECT-TYPE SYNTAX INTEGER{ powerUp (1), parityError (2), watchDog (3), resourceOverflow (4), clrAllCnf (5), missingTask (6), pxmLowVoltage(7), resetByEventLogTask(8), resetFromShell(9), unknown(10), resetFromPXM(11), resetSys(12), switchCC(13), sCacheError(14), swError(15), upgrade(16), restoreAllCnf(17), driverError(18) } ACCESS read-only STATUS mandatory DESCRIPTION "Last reason for card to reset. The possible values are : powerUp(1) : power up parityError(2) : parity error watchDog(3) : watchdog resourceOverflow (4) : resource overflow clrAllCnf (5) : configuration of the shelf is cleared. missingTask (6) : task is missing pxmLowVoltage(7): low voltage detected on PXM resetByEventLogTask(8): resetFromShell(9): command is run from command shell unknown(10) : resetFromPXM(11) : Controller Card(PXM) reset the card. resetSys(12) : due to resetsys CLI Command. switchCC(13) : due to switch over CLI command. sCacheError(14) : swError(15) : software error. upgrade(16) : upgrade restoreAllCnf(17): restore configuration. driverError(18) : driver error. Valid values for VISM: powerUp, watchDog, resetFromShell and resetFromPXM. " ::= { cardInformation 8 } lineModuleType OBJECT-TYPE SYNTAX INTEGER { other (1), lm-ASC (2), lm-DB15-4T1 (16), lm-DB15-4E1 (17), lm-BNC-4E1 (18), lm-DB15-4T1-R(19), lm-DB15-4E1-R(20), lm-BNC-4E1-R (21), lm-RJ48-8T1 (22), lm-RJ48-8E1 (23), lm-SMB-8E1 (24), lm-RJ48-T3T1 (25), lm-RJ48-E3E1 (26), lm-RJ48-T3E1 (27), lm-SMB-E3E1 (28), lm-RJ48-E3T1 (29), lm-SMB-T3E1 (30), lm-T3E3-D (32), lm-T3E3-B (33), lm-155-SMF (34), lm-155-UTP (35), lm-RJ48-8T1-R(48), lm-RJ48-8E1-R(49), lm-SMB-8E1-R (50), lm-3T3-B (51), -- HSSI/X.21 lm-HS1-4X21 (60), lm-HS1-3HSSI (61), -- HSSI/X.21 lm-HS1-4V35 (62), lm-12In1-8s (63), lm-BSCSM-2 (70), lm-BSCSM-4 (71), lm-BNC-2T3 (80), lm-BNC-2E3 (81), pxm-ui (500), smfir-1-622 (501), smflr-1-622 (502), smfir15-1-622 (503), smflr15-1-622 (504), mmf-4-155 (505), smfir-4-155 (506), smflr-4-155 (507), rj45-fe (511), mmf-fe (512), mmf-fddi (513), smf-fddi (514), rj45-4e (515), pxm-ui-s3 (1006), -- SRME back card lm-srme-1OC3-smlr (1050), lm-srme-1OC3-smir (1051), lm-srme-1OC3-smb (1052) } ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the Line Module(back card) type. Physically it is behind the backplane, normally with connectors for physical devices. These are specific to the front or functional modules. " DEFVAL { other } ::= { cardInformation 9 } lineModuleDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains description of the line module." ::= { cardInformation 10 } lineModuleSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains Serial number of the line module." ::= { cardInformation 11 } lineModuleHWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains Hardware revision for line module." ::= { cardInformation 12 } lineModuleFWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware revision for line module. The current version does not have any firmware, hence will always contains zero length octet string." ::= { cardInformation 13 } lineModuleState OBJECT-TYPE SYNTAX INTEGER { notPresent (1), present (2), invalid (3) } ACCESS read-only STATUS mandatory DESCRIPTION "line module status." ::= { cardInformation 14 } moduleTrapAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { minor (1), major (2), dontCare (3), critical (4), error (5), warning (6), notice (7), info (8) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is sent to managers as part of all Trap PDUs, to determine the module alarm severity. An implementation may not support all the possible values. The Possible values are : major (1) : Major Service has been impacted minor (2) : Minor Service has been lost dontCare (3) : severity is not applicable critical (4) : affects existing data traffic error (5) : error has occurred warning (6) : a threshold has been reached notice (7) : a normal but significant event has occurred info (8) : informational " ::= { cardInformation 15 } mibVersionNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "MIB version number. Updated when any part of the MIB changes. " DEFVAL { 2 } ::= { cardInformation 16 } configChangeTypeBitMap OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Configuration change Type BitMap bit 0 set = Card Configuration Change bit 1 set = Line Configuration Change bit 2 set = Port Configuration Change bit 3 set = Chan Configuration Change bit 4 set = STUN protocol group configuration Change bit 5 set = STUN port configuration Change bit 6 set = STUN route configuration Change bit 7 set = BSTUN protocol configuration Change bit 8 set = BSTUN port configuration Change bit 9 set = BSTUN route configuration Change bit 10 set = FRASBNN route configuration Change bit 11 set = FRASBAN route configuration Change bit 12 set = SDLC port configuration Change bit 13 set = SDLC LS configuration Change bit 14 set = BSC port configuration Change bit 15 set = LLC port configuration Change bit 16 set = card LCN partition change (controller based only) bit 17 set = port resource partition change (under any partition type) bit 18 set = VISM Endpoint Configuration Change bit 19 set = Egress Q configuration change default value is 0, no change This object makes sense only in traps. A GET on this may not return a Useful result. Bit 19 is not applicable for MGX 8850 Release 1.x.x and MGX 8220 " DEFVAL { 0 } ::= { cardInformation 17 } configChangeObjectIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "Configuration change object index, could be line number or port number or channel number depends on the type bitmap, for port resouce partition change (bit 17), this index is actually constructed by (portNum << 16 | controller) because the table has two indices. When the 'Line Configuration Change' bit is set, the configChangeObjectIndex has the following special meanings in IMATM and FRSM-2CT3 cards: IMATM - configChangeObjectIndex range between 1..8 indicates that the configuration change refers to the DS1 line index. A value of 9 indicates that the configuration change refers to the DS3 line index. FRSM-2CT3 - configChangeObjectIndex range between 1..56 indicates that the configuration change refers to the DS1 line index. A value of (128 + n) refers to DS3 line index numbered 'n'. This object makes sense only in traps. A GET on this may not return a Useful result. " ::= { cardInformation 18 } configChangeStatus OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "This object is applicable only for traps. The SNMP operation may not be meaningful. The value contained in this object is same as the value of the other objects which are used for adding/deleting/modifying the row. The possible values are 0 - No meaning and is not applicable. 1 - add [ Row added ] 2 - delete [ Row deleted ] 3 - mod [ Row modified ] This value and value contained in configChangeTypeBitMap represent the configuration change operation. The default value is 0 and it does not represent any status." DEFVAL {0} ::= { cardInformation 19 } cardIntegratedAlarmBitMap OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bit position represents the different types of alarm for ASC: bit 0: ShelfFunctionModuleState (BNM only) (failed/boot/mismatch/heldinReset) bit 1: LineModuleState (BNM only) (notPresent/invalid) bit 2: ASMPhysicalAlarmState (BNM only) bit 3: ATMLMIFailure (ASC only) bit 4: LineAlarmState (BNM only) bit 5: LineStatisticalAlarmState (BNM only) bit 6: PLCPAlarmState (BNM only) bit 7: PLCPStatisticalAlarmState (BNM only) bit 8: SmConnectionFailureAlarm for SM: bit 0: ShelfFunctionModuleState (failed/boot/mismatch/heldinReset) bit 1: LineModuleState (notPresent/invalid) bit 2: PortLMIFailure bit 3: LineAlarmState bit 4: LineStatisticalAlarmState bit 5: FrameRelayPortState (RemoteLoopback/ FailedDueToLine/ FailedDueToSig) bit 6: ChannelState for PXM/SRM Only (MGX8850 Platfrom): Only those marked with SRM are valid for both PXM/SRM. The rest are valid only for PXM. bit 0 : ShelfFunctionModuleState bit 1 : Backcard Line Module (SRM/PXM) This Alarm is generated when the Line Module (Trunk Backcard) is removed or goes to a mismatch state(or backcard type is unknown). bit 2 : Backcard UIModule This Alarm is generated when the UI backcard is removed or goes to a mismatch state (or backcard type is unknown). bit 3 : ASM Physical Alarm This specifies whether any of the environmental monitoring components like Temperature, Voltage Supply, Fan Speed have gone into alarm. bit 4 : ATM LMI Failure bit 5 : Line Alarm (SRM/PXM) bit 6 : Line Statistical Alarm (SRM/PXM) bit 7 : Lines Alarm (SRM/PXM) bit 8 : PLCP Alarm bit 9 : PLCP Statistical Alarm bit 10 : Connections exist on removed SM bit 11 : Disk related Failure on first PXM slot bit 12 : Disk related Failure on second PXM slot The Disk Alarms are generated when any of the file operations on Disk like open,read,write, lseek etc fail. VSM Alarms bit 13 : Port LMI Failure bit 14 : Port State Alarm bit 15 : Channel Shelf Alarm bit 16 : Taskmon Task Suspended bit 17 : Excess Power Consumption bit 30 : bit set(1) major alarm, else (0) minor alarm " DEFVAL {0} ::= { cardInformation 20 } cleiCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "Common Language Equipment(CLEI) Code. " ::= { cardInformation 21 } macAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet address (base address) stored in NVRAM, entered by manfacturing. " ::= { cardInformation 22 } macAddrBlkSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address block size, entered by manufacturing. " ::= { cardInformation 23 } finalTestTechnician OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) ACCESS read-only STATUS mandatory DESCRIPTION "The Final Test Technician Employee Identification Number. " ::= { cardInformation 24 } hwFailures OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Hardware failure code." ::= { cardInformation 25 } hwHistory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RMA Test History - RMA Failure Code." ::= { cardInformation 26 } secLineModuleType OBJECT-TYPE SYNTAX INTEGER { other (1), lm-ASC (2), lm-DB15-4T1 (16), lm-DB15-4E1 (17), lm-BNC-4E1 (18), lm-DB15-4T1-R(19), lm-DB15-4E1-R(20), lm-BNC-4E1-R (21), lm-RJ48-8T1 (22), lm-RJ48-8E1 (23), lm-SMB-8E1 (24), lm-RJ48-T3T1 (25), lm-RJ48-E3E1 (26), lm-RJ48-T3E1 (27), lm-SMB-E3E1 (28), lm-RJ48-E3T1 (29), lm-SMB-T3E1 (30), lm-T3E3-D (32), lm-T3E3-B (33), lm-155-SMF (34), lm-155-UTP (35), lm-RJ48-8T1-R(48), lm-RJ48-8E1-R(49), lm-SMB-8E1-R (50), lm-3T3-B (51), lm-HS1-4X21 (60), lm-HS1-3HSSI (61), -- HSSI/X.21 lm-HS1-4V35 (62), lm-12In1-8s (63), lm-BSCSM-2 (70), lm-BSCSM-4 (71), lm-BNC-2T3 (80), lm-BNC-2E3 (81), pxm-ui (500), smfir-1-622 (501), smflr-1-622 (502), smfir15-1-622 (503), smflr15-1-622 (504), mmf-4-155 (505), smfir-4-155 (506), smflr-4-155 (507), rj45-fe (511), mmf-fe (512), mmf-fddi (513), smf-fddi (514), rj45-4e (515), pxm-ui-s3 (1006) } ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the type of secondary line module(back card). Physically it is the bottom card behind the backplane. Normally with connectors for physical devices. These are specific to the front or function modules. This Object is applicable only to selected MGX switches. " DEFVAL { other } ::= { cardInformation 27 } secLineModuleDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of the Secondary line module. This Object is applicable only to selected MGX switches. " ::= { cardInformation 28 } secLineModuleSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "Serial number of the secondary(bottom) line module. This object is applicable only to selected MGX switches. " ::= { cardInformation 29 } secLineModuleHWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..2)) ACCESS read-only STATUS mandatory DESCRIPTION "Hardware revision for secondary (bottom) line module This object is applicable only to selected MGX switches. " ::= { cardInformation 30 } secLineModuleFWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Firmware revision for Secondary line module This object is applicable only to selected MGX switches. If there is no Firmware revision, then this object returns 0. " ::= { cardInformation 31 } secLineModuleState OBJECT-TYPE SYNTAX INTEGER { notPresent (1), present (2), invalid (3) } ACCESS read-only STATUS mandatory DESCRIPTION "line module status of secondary (bottom) back card. This object is applicable only to selected MGX switches." ::= { cardInformation 32 } configChangeParentObjectIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION " Parent object index, could be - line index - port index This object will indicate the index of the immediate higher level object (line or port) of configChangeObjectIndex. This object is applicable only when configChangeObjectIndex represents a channel, port, egress Q or resource partition index. Following specifies the mapping between the configChangeObjectIndex and its corresponding configChangeParentObjectIndex. configChangeObjectIndex configChangeParentObjectIndex ----------------------- ----------------------------- Port Index Line Index Egress Q Index Port Index Resource Partition Index Port Index Channel Index Port Index When the 'Port Configuration Change' bit is set, the configChangeParentObjectIndex will represent a 'Line Index' which in turn has the following special meaning in FRSM-2CT3 cards. - configChangeParentObjectIndex range between 1..56 indicates that the configuration change refers to the DS1 line index. A value of (128 + n) refers to DS3 line index numbered 'n'. This object object is applicable only in traps. A GET on this may not return a useful result. This object Object is not applicable to MGX 8850 Release 1.x.x and MGX8220 " ::= { cardInformation 33 } configChangeGrandParentObjectIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION " Grand Parent object index, could be - line index This object will indicate the index of the immediate higher level object (line) of configChangeParentObjectIndex. This object is applicable only when configChangeParentObjectIndex represents a port index. Following specifies the mapping between the configChangeParentObjectIndex and its corresponding configChangeGrandParentObjectIndex. When the 'Port Configuration Change' bit is set the configChangeGrandParentObjectIndex will represent a 'Line Index' which in turn has the following special meaning in FRSM-2CT3 cards. - configChangeParentObjectIndex range between 1..56 indicates that the configuration change refers to the DS1 line index. A value of (128 + n) refers to DS3 line index numbered 'n'. This object is applicable only in traps. A GET on this may not return a useful result. This object is not applicable to MGX 8850 release 1.x.x and MGX8220." ::= { cardInformation 34 } configChangeSMSpecificObject OBJECT-TYPE SYNTAX INTEGER (0..'ffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION " configChangeSMSpecificObject is a generic object which is Service Module Specific. It can be used for different purposes in different cards. The usage of the same with regard to very card type is listed below. FRSM-8T1E1 - used to store portDs0ConfigBitMap FRSM-VHS - used to store portDs0ConfigBitMap CESM-8T1E1 - used to store cesPortDs0ConfigBitMap CESM-T3E3 - not used AUSM-8T1E1 - not used This object is not applicable to MGX 8850 Release 1.x.x and MGX8220." ::= { cardInformation 35 } transId OBJECT-TYPE SYNTAX INTEGER (0..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "Per card transaction ID. This object is used to keep track of configuration change on the card. The transId will be incremented by one for every configuration change on the card." ::= { cardInformation 36 } -- ****************************************************************** -- -- Group "Interface" -- This group contains list of physical interfaces and service types -- available on a card. -- Different line types are e.g. DS1,DS3,OC3 etc. -- Different services are e.g. ATM,FrameRelay etc. -- Any combination of line type and service type are possible for a card. -- -- ****************************************************************** interfaceNumOfValidEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of rows in interface Table The number represents the physcial interfaces the module has. " ::= { cardInterface 2 } interfaceLineTable OBJECT-TYPE SYNTAX SEQUENCE OF InterfaceLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table has list of the physical interfaces and the services available on this module. " ::= { cardInterface 1 } interfaceLineEntry OBJECT-TYPE SYNTAX InterfaceLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry for physical interface " INDEX { interfaceLineNum } ::= { interfaceLineTable 1 } InterfaceLineEntry ::= SEQUENCE { interfaceLineNum INTEGER, interfaceLineType INTEGER, interfaceNumOfPortsPerLine INTEGER, interfaceServiceType INTEGER, interfaceNumOfPVC INTEGER, interfaceNumOfEgressQueue INTEGER } interfaceLineNum OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "An index to uniquely indentify the physical interface and service. Indices 1..8 are used for VISM-8T1/E1. " ::= { interfaceLineEntry 1 } interfaceLineType OBJECT-TYPE SYNTAX INTEGER { other(1), ds1(18), e1(19), ethernet-3Mbit (26), ds3(30), rs232(33), v35(45), -- HSSI/X.21 -- Unable to find for X.21 interface hssi(46) -- HSSI/X.21 } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the type of interfaces provided by this Module. These numbers are from RFC1700." ::= { interfaceLineEntry 2 } interfaceNumOfPortsPerLine OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number of physical ports of the line type. VISM has a port, but is not linked to these physical lines, hence value=0 is returned. " DEFVAL {672} ::= { interfaceLineEntry 3 } interfaceServiceType OBJECT-TYPE SYNTAX INTEGER { other(1), ethernet-3Mbit (26), slip (28), frameRelay(32), atm(37), voice(42) } ACCESS read-only STATUS mandatory DESCRIPTION "The services available on the interfaceLineType object " ::= { interfaceLineEntry 4 } interfaceNumOfPVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Max number of Permanent Virtual Channels available per physical line (line as defined in interfaceLineType). VISM has a PVC but is not linked to the lines, hence value=0 is returned. " ::= { interfaceLineEntry 5 } interfaceNumOfEgressQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Max number of Queues per port. Value=0 is returned for VISM card. " ::= { interfaceLineEntry 6 } -- ---------------------------------------------------------------- -- -- Group "cardTest" -- The cardTest group contains self test results. -- All cards in BASIS have this group defined. -- -- ---------------------------------------------------------------- selfTestEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the self test state 1 ==> self test enabled 2 ==> self test disabled " DEFVAL { disable } ::= { cardSelfTest 1 } selfTestPeriod OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Interval (in minutes) for self test. " DEFVAL { 1 } ::= { cardSelfTest 2 } selfTestState OBJECT-TYPE SYNTAX INTEGER { passed (1), failed (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Self test results for the module. " ::= { cardSelfTest 3 } selfTestResultDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Self test Result description " ::= { cardSelfTest 4 } selfTestClrResultButton OBJECT-TYPE SYNTAX INTEGER { other (1), clear (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used for clearing the result of an online diagnostics(or other self tests)." ::= { cardSelfTest 5 } controlMsgCounter OBJECT IDENTIFIER ::= { cardGeneric 4 } riscXmtCtrlMsg OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of control Frames transmitted to SAR (from RISC) maintained by RISC " ::= { controlMsgCounter 1 } riscRcvCtrlMsg OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of control Frames received from SAR (to RISC) maintained by RISC " ::= { controlMsgCounter 2 } sarXmtCtrlMsg OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of control Frames transmitted to RISC from SAR maintained by SAR (should be equal to (riscRcvCtrlMsg) " ::= { controlMsgCounter 3 } sarRcvCtrlMsg OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of control Frames received to SAR from RISC maintained by SAR (should be equal to (riscXmtCtrlMsg) " ::= { controlMsgCounter 4 } sarCtrlMsgDiscLenErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total control (management) frames (for MGX8800) or cells(for MGX8220) discarded due to illegal length error " ::= { controlMsgCounter 5 } sarCtrlMsgDiscCRCErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total control (management) frames (MGX8800) or cells(MGX8220) discard due to illegal CRC error. " ::= { controlMsgCounter 6 } sarCtrlMsgDiscUnknownChan OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Count of discarded control message due to unknown channel error." ::= { controlMsgCounter 7 } sarCtrlMsgLastUnkownChan OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The control cell header Rcvd of the last unknown channel." ::= { controlMsgCounter 8 } ctrlMsgClrButton OBJECT-TYPE SYNTAX INTEGER { other (1), clear (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used for clearing the messages in controlMsgCounter group." ::= { controlMsgCounter 9 } sarChannelCounter OBJECT IDENTIFIER ::= { cardGeneric 5 } -- ---------------------------------------------------------------- -- -- Group "sarCounters" -- This group contains list of SAR counters and RISC counters -- This group is common to all cards. All cards in BASIS have -- SAR and RISC counters. -- -- ---------------------------------------------------------------- -- --------------------------------------------------------------------- -- -- SAR channel counters group -- -- These are counter maintained by the SAR and supplied to the -- manager by RISC, the counters are per VC and counters are -- for ATM cells -- -- cell counters -- --------------------------------------------------------------------- chanNumOfValidEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the sar channel table " ::= { sarChannelCounter 2 } sarChannelCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF SarChannelCounterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table is for logical channels This table contains the counters for cells transmitted on each channel." ::= { sarChannelCounter 1 } sarChannelCounterEntry OBJECT-TYPE SYNTAX SarChannelCounterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " An entry for logical channel " INDEX { sarShelfNum, sarSlotNum, sarChanNum } ::= { sarChannelCounterTable 1 } SarChannelCounterEntry ::= SEQUENCE { sarShelfNum INTEGER, sarSlotNum INTEGER, sarChanNum INTEGER, -- Xmt Cell stats xmtCells Counter, xmtCellsCLP Counter, xmtCellsAIS Counter, xmtCellsFERF Counter, xmtCellsBCM Counter, xmtCellsEnd2EndLpBk Counter, xmtCellsSegmentLpBk Counter, xmtCellsDiscShelfAlarm Counter, -- Rcv Cell stats rcvCells Counter, rcvCellsCLP Counter, rcvCellsAIS Counter, rcvCellsFERF Counter, rcvCellsBCM Counter, rcvCellsEnd2EndLpBk Counter, rcvCellsSegmentLpBk Counter, rcvCellsDiscOAM Counter, sarClrButton INTEGER } sarShelfNum OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Shelf number " ::= { sarChannelCounterEntry 1 } sarSlotNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "Slot number, the slot and shelf info is required here because BSC sends the OAM cells for the FRSM cards that have failed BSC could have upto 4000 connections in this table." ::= { sarChannelCounterEntry 2 } sarChanNum OBJECT-TYPE SYNTAX INTEGER (0..4015) ACCESS read-only STATUS mandatory DESCRIPTION " BSC could have upto 4000 connections in this table " ::= { sarChannelCounterEntry 3 } xmtCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells transmitted on this channel. " ::= { sarChannelCounterEntry 4 } xmtCellsCLP OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of CLP cells that were transmitted on this channel." ::= { sarChannelCounterEntry 5 } xmtCellsAIS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of AIS cells that were transmitted on this channel. " ::= { sarChannelCounterEntry 6 } xmtCellsFERF OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FERF cells that were transmitted on this channel. " ::= { sarChannelCounterEntry 7 } xmtCellsBCM OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BCM cells that were transmitted on this channel." ::= { sarChannelCounterEntry 8 } xmtCellsEnd2EndLpBk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of End2End loop cells that were transmitted on this channel." ::= { sarChannelCounterEntry 9 } xmtCellsSegmentLpBk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of segment loop cells that were transmitted on this channel." ::= { sarChannelCounterEntry 10 } xmtCellsDiscShelfAlarm OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells discard due to Shelfalarm on this channel. " ::= { sarChannelCounterEntry 11 } -- receiver cell counters rcvCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that were received on this channel. " ::= { sarChannelCounterEntry 12 } rcvCellsCLP OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CLP cells that were received on this channel. " ::= { sarChannelCounterEntry 13 } rcvCellsAIS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of AIS cells that were received on this channel. " ::= { sarChannelCounterEntry 14 } rcvCellsFERF OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FERF cells that were received on this channel. " ::= { sarChannelCounterEntry 15 } rcvCellsBCM OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BCM cells that were received on this channel. " ::= { sarChannelCounterEntry 16 } rcvCellsEnd2EndLpBk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of End2End loop cells that were received on this channel." ::= { sarChannelCounterEntry 17 } rcvCellsSegmentLpBk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of segment loop cells that were received on this channel. " ::= { sarChannelCounterEntry 18 } rcvCellsDiscOAM OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that had CRC error on OAM cells " ::= { sarChannelCounterEntry 19 } sarClrButton OBJECT-TYPE SYNTAX INTEGER { other (1), clear (2) } ACCESS read-write STATUS mandatory DESCRIPTION "clear the counters in the table " ::= { sarChannelCounterEntry 20 } END