CISCO-WAN-FR-X21-MIB device MIB details by Stratacom
CISCO-WAN-FR-X21-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing CISCO-WAN-FR-X21-MIB.
Vendor: | Stratacom |
---|---|
Mib: | CISCO-WAN-FR-X21-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- ***************************************************************** -- ciscoWanFrX21LineMIB -- -- September 2002, Subra Hegde -- -- Copyright (c) 2002 by cisco Systems, Inc. -- All rights reserved. -- **************************************************************** CISCO-WAN-FR-X21-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF x21, frPortCnfX21PortGrp FROM BASIS-MIB ciscoWan FROM CISCOWAN-SMI; ciscoWanFrX21MIB MODULE-IDENTITY LAST-UPDATED "200209190000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB module to configure X.21/HSSI physical and logical interfaces. This MIB module also contains alarm configuration of X.21 interfaces. Terminologies Used: HSSI : High Speed Serial Interface. The HSSI defines both electrical and physical interfaces on DTE and DCE devices. It operates at the physical layer of the OSI reference model. This provides high-speed data communication over WAN and LAN links." REVISION "200209190000Z" DESCRIPTION "Initial version of the MIB. The content of this MIB was originally available in CISCO-WAN-AXIPOP-MIB defined using SMIv1. The applicable objects from CISCO-WAN-AXIPOP-MIB are defined using SMIv2 in this MIB." ::= { ciscoWan 49 } x21CnfGrp OBJECT IDENTIFIER ::= { x21 1 } x21AlmCnfGrp OBJECT IDENTIFIER ::= { x21 2 } x21AlmGrp OBJECT IDENTIFIER ::= { x21 3 } -- ********************************************************************** -- X.21 Config Group -- -- This group contains X.21 line configuration table -- ********************************************************************** x21CnfGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF X21CnfGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The X21 Configuration table. The table size is given by the value of x21LineNumofValidEntries." ::= { x21CnfGrp 1 } x21CnfGrpEntry OBJECT-TYPE SYNTAX X21CnfGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the X21 Configuration table." INDEX { x21LineNum } ::= { x21CnfGrpTable 1 } X21CnfGrpEntry ::= SEQUENCE { x21LineNum Integer32, x21LineEnable INTEGER, x21LineType INTEGER, x21LineRate INTEGER, x21LineLoopbackCommand INTEGER, x21LineSendCode INTEGER, x21LineLoopbackCodeDetection INTEGER, x21ConnectorType INTEGER, x21InvertClock INTEGER, x21LineInterfaceType INTEGER, x21ClkFrequencyThreshold Integer32, serialLineRate Integer32, serialLineRateVariation Integer32 } x21LineNum OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the identifier of a X.21 interface. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8." ::= { x21CnfGrpEntry 1 } x21LineEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), modify (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable disables, enables or modifies a line 1 - disable 2 - enable 3 - modify Default is enable. " ::= { x21CnfGrpEntry 2 } x21LineType OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), dteST (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the type X21 line type. The line-type affects the clock -- the DCE device always provides the clock and DTE accepts it. dteST is only applicable to V.35 interfaces Default is DTE. " ::= { x21CnfGrpEntry 3 } x21LineRate OBJECT-TYPE SYNTAX INTEGER { r48Kbps(1), r56Kbps(2), r64Kbps(3), r112Kbps(4), r128Kbps(5), r168Kbps(6), r192Kbps(7), r224Kbps(8), r256Kbps(9), r280Kbps(10), r320Kbps(11), r336Kbps(12), r384Kbps(13), r392Kbps(14), r448Kbps(15), r512Kbps(16), r768Kbps(17), r1024Kbps(18), r1536Kbps(19), r1544Kbps(20), r1792Kbps(21), r1920Kbps(22), r1984Kbps(23), r2048Kbps(24), r3097Kbps(25), r3157Kbps(26), r4096Kbps(27), r4645Kbps(28), r4736Kbps(29), r6195Kbps(30), r6315Kbps(31), r7744Kbps(32), r7899Kbps(33), r8192Kbps(34), r9289Kbps(35), r9472Kbps(36), r10240Kbps(37), r10890Kbps(38), r11060Kbps(39), r12390Kbps(40), r12630Kbps(41), r13900Kbps(42), r14220Kbps(43), r14340Kbps(44), r15490Kbps(45), r15800Kbps(46), r16380Kbps(47), r20030Kbps(48), r24990Kbps(49), r52Mbps(50), -- FRSM_VHS added for frsm_vhs r17370Kbps(51), r18950Kbps(52), r20530Kbps(53), r22100Kbps(54), r23680Kbps(55), -- -- n*T1 rates. Added for FRSM_VHS -- note that 1.544Kbps is already enumerated above -- r3088Kbps(56), r4632Kbps(57), r6176Kbps(58), r7720Kbps(59), r9264Kbps(60), r10808Kbps(61), r12352Kbps(62), r13896Kbps(63), r15440Kbps(64), r16984Kbps(65), r18528Kbps(66), r20072Kbps(67), r21616Kbps(68), r23160Kbps(69), r24704Kbps(70), r26248Kbps(71), r27792Kbps(72), r29336Kbps(73), r30880Kbps(74), r32424Kbps(75), r33968Kbps(76), r35512Kbps(77), r37056Kbps(78), r38600Kbps(79), r40144Kbps(80), r41688Kbps(81), r43232Kbps(82), r44776Kbps(83), r46320Kbps(84), r47864Kbps(85), r49408Kbps(86), r50952Kbps(87), -- -- n*E1 rates. Added for FRSM_VHS. -- r6144Kbps(88), r12288Kbps(89), r14336Kbps(90), r16384Kbps(91), r18432Kbps(92), r20480Kbps(93), r22528Kbps(94), r24576Kbps(95), r26624Kbps(96), r28672Kbps(97), r30720Kbps(98), r32768Kbps(99), r34816Kbps(100), r36864Kbps(101), r38912Kbps(102), r40960Kbps(103), r43008Kbps(104), r45056Kbps(105), r47104Kbps(106), r49152Kbps(107), r51200Kbps(108) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable configures the X.21/HSSI/V.35 line-rate. Note that enumerations 51 through 108 are supported only by FRSM-HS2/HS2B card. default is r48Kbps on FRSM-HS2B-12IN1 default is r52Mbps on FRSM-HS2/HS2B-HSSI " ::= { x21CnfGrpEntry 4 } x21LineLoopbackCommand OBJECT-TYPE SYNTAX INTEGER { x21NoLoop (1), x21DiagnosticMetallicLoop (2), x21DiagnosticFrontcardLoop (3), x21RemoteLoop (4), v35MetallicLoop (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the loopback state x21NoLoop Not in the loopback state. Normal traffic can be sent x21DiagnosticMetallicLoop Loopbacks the line on the back-card towards the Network. x21DiagnosticFrontcardLoop Loopbacks the line on the frontcard toward the Network. x21RemoteLoop The remote NTU is in the loop back mode. In this state, the FRSM-HS1 is sending the loopback code to remote NTU. Default is x21NoLoop. Note: Before going into one of the loopbacks the state should be x21NoLoop. " ::= { x21CnfGrpEntry 5 } x21LineSendCode OBJECT-TYPE SYNTAX INTEGER { x21NoCode (1), x21SendLoopACode (2), x21SendLoopBCode (3), x21SendLocalLoopCode (4), x21SendRemoteLoopCode (5), x21SendUnLoopCode (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the X.21/HSSI interface by the device. The values mean: x21NoCode: No loopback. x21SendLoopACode: Start sending Loop A code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the line module of the remote device. x21SendLoopBCode: Start sending Loop B code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the digital section of the remote device. x21SendLocalLoopCode: Start sending CCITT X.21 Loopback Type 3 code. This is valid only if the backcard is X.21 type. x21SendRemoteLoopCode: Start sending CCITT X.21 Loopback Type 2 code. This is valid only if the backcard is X.21 type. x21SendUnLoopCode: Sending a loopback termination request. Valid for both HSSI and X.21 lines. To execute any of the loop-codes the x21LineLoopbackCommand should be set to x21RemoteLoop. Once the x21SendUnLoopCode succeeds the x21LineLoopbackCommand would transition back to x21NoLoop state. Default is x21NoCode." ::= { x21CnfGrpEntry 6 } x21LineLoopbackCodeDetection OBJECT-TYPE SYNTAX INTEGER { codeDetectDisabled (1), codeDetectEnabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable detection of line Loopback Codes. The loopback detection is implemented only in HSSI DCE mode. Default is codeDetectDisabled." ::= { x21CnfGrpEntry 7 } x21ConnectorType OBJECT-TYPE SYNTAX INTEGER { x21Backcard (1), hssiBackcard (2), v35Backcard (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "back card type This object is not used by FRSM-HS2/HS2B " ::= { x21CnfGrpEntry 8 } x21InvertClock OBJECT-TYPE SYNTAX INTEGER { nonInvertedAndNotLooped (1), invertedAndNotLooped (2), nonInvertedAndLooped (3), invertedAndLooped (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures two options: a) To invert the clock sent by HS1/HS2B with the TX data or not. b) If DCE,to expect the receive clock looped back from DTE or not. If DTE,to loop back the receive clock from DCE or not. nonInvertedAndNotLooped(1)- a)=dont invert, b)=dont expect rcv clock/ dont loop rcv clock invertedAndNotLooped(2) - a)=invert, b)=dont expect rcv clock/ dont loop rcv clock nonInvertedAndLooped(3) - a)=dont invert, b)=expect rcv clock/ loop rcv clock invertedAndLooped(4) - a)=invert, b)=expect rcv clock/ loop rcv clock Enums 1 and 2 are applicable for X.21/HSSI/V.35 interfaces. Enums 3 and 4 are applicable only for V.35. Default for X.21/HSSI is nonInvertedAndNotLooped(1) Default for V.35 is nonInvertedAndLooped(3) This object is not used by FRSM-HS2/FRSM-HS2B-HSSI This object is used by FRSM-HS2B-12IN1 and default values are nonInvertedAndNotLooped(1) for X.21, nonInvertedAndLooped(3) for V.35." ::= { x21CnfGrpEntry 9 } x21LineInterfaceType OBJECT-TYPE SYNTAX INTEGER { hssi(1), x21 (2), v35 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates serial interface type. Default is hssi(1). This object is not is configurable in FRSM-HS2 and FRSM-HS2B-HSSI. It will be set to hssi(1) by default for these cards This object is configurable in FRSM-H2B-12IN1. Default is v35(3)." ::= { x21CnfGrpEntry 10} x21ClkFrequencyThreshold OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates user configurable percentage of clock frequency, which is used by DTE clock monitoring to declare clock rate out of bound alarm. This object is valid only for X.21/v.35/HSSI DTE interfaces. This object is supported by FRSM-HS2 and FRSM-HS2/B" DEFVAL { 3 } ::= { x21CnfGrpEntry 11} serialLineRate OBJECT-TYPE SYNTAX Integer32 (48000..51840000) MAX-ACCESS read-write STATUS current DESCRIPTION "Line rate for X.21/HSSI/V.35 interfaces in bps. This object is supported only by FRSM-HS2/B card, only multiples of 1000 are accepted. Default is 48Kbps for X.21/V.35 interfaces and 51840Kbps for HSSI interface." ::= { x21CnfGrpEntry 12} serialLineRateVariation OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates line rate variation of HSSI/X.21/V.35 DCE interfaces in ppm (parts per million). i.e. clock generated from DCE hardware interface = (serialLineRate +/- (serialLineRateVariation * 10^6)/ serialLineRate) This object is supported only by FRSM-HS2/B card " ::= { x21CnfGrpEntry 13} x21LineNumofValidEntries OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of X.21/HSSI configuration entries (regardless of their current configuration) in the x21ConfigTable table." ::= { x21CnfGrp 2 } -- ****************************************************************** -- -- -- LOGICAL PORT CONFIG Group -- -- -- ****************************************************************** frPortCnfX21PortGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF FrPortCnfX21PortGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The config table is for X.21/HSSI logical port interface " ::= { frPortCnfX21PortGrp 1 } frPortCnfX21PortGrpEntry OBJECT-TYPE SYNTAX FrPortCnfX21PortGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry for logical port." INDEX { x21portNum } ::= { frPortCnfX21PortGrpTable 1 } FrPortCnfX21PortGrpEntry ::= SEQUENCE { x21portNum Integer32, x21portLineNum Integer32, x21portRowStatus INTEGER, x21portFlagsBetweenFrames Integer32, x21portEqueueServiceRatio Integer32, x21portSpeed Integer32, x21portAdmin INTEGER, x21portType INTEGER, x21portSvcStatus INTEGER, x21portSvcInUse INTEGER, x21portSvcShareLcn INTEGER, x21portSvcLcnLow Integer32, x21portSvcLcnHigh Integer32, x21portSvcDlciLow Integer32, x21portSvcDlciHigh Integer32, x21portDeleteSvcs INTEGER, x21portIngrSvcBandW Integer32, x21portEgrSvcBandW Integer32 } x21portNum OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "This is logical port number. The HSSI backcard can support upto 3 ports. The X.21 back card can support 4 logical ports." ::= { frPortCnfX21PortGrpEntry 1} x21portLineNum OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "This represents the line number. On FRSM-HS1 the HSSI can support 3 lines and X.21 4 lines." ::= { frPortCnfX21PortGrpEntry 2} x21portRowStatus OBJECT-TYPE SYNTAX INTEGER { add(1), del(2), mod(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable adds, deletes, or modifies the port 1- add 2 - delete 3 - modify Default is add." ::= { frPortCnfX21PortGrpEntry 3 } x21portFlagsBetweenFrames OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of flags transmitted between two consecutive HDLC frames. Default is 1 flag." ::= { frPortCnfX21PortGrpEntry 4 } x21portEqueueServiceRatio OBJECT-TYPE SYNTAX Integer32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times queue 1 is serviced for every time queue 2 is serviced. Default is 1." ::= { frPortCnfX21PortGrpEntry 5 } x21portSpeed OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Port speed in kbps. At present it is same as line speed." ::= { frPortCnfX21PortGrpEntry 6 } x21portAdmin OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), write-Only(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used for administratively changing the status of the port. Up/down used to up and down the port. Default is the up state." ::= { frPortCnfX21PortGrpEntry 7 } x21portType OBJECT-TYPE SYNTAX INTEGER { frame-relay (1), frFUNI (2), frame-forward (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This represents port type. The processing of the frames depends on the type of the port." ::= { frPortCnfX21PortGrpEntry 8 } x21portSvcStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This represents SVC status." ::= { frPortCnfX21PortGrpEntry 9 } x21portSvcInUse OBJECT-TYPE SYNTAX INTEGER { not-use (1), in-use (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This represents port SVC in use." ::= { frPortCnfX21PortGrpEntry 10 } x21portSvcShareLcn OBJECT-TYPE SYNTAX INTEGER { port-based(1), card-based(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This represents port type." ::= { frPortCnfX21PortGrpEntry 11 } x21portSvcLcnLow OBJECT-TYPE SYNTAX Integer32 (16..271) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents low end of reserved LCN for SVC." ::= { frPortCnfX21PortGrpEntry 12 } x21portSvcLcnHigh OBJECT-TYPE SYNTAX Integer32 (16..271) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents high end of reserved LCN for SVC." ::= { frPortCnfX21PortGrpEntry 13 } x21portSvcDlciLow OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents low end of reserved DLCI for SVC." ::= { frPortCnfX21PortGrpEntry 14 } x21portSvcDlciHigh OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents high end of reserved DLCI for SVC." ::= { frPortCnfX21PortGrpEntry 15 } x21portDeleteSvcs OBJECT-TYPE SYNTAX INTEGER { delete(1), other(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 1 indicates that all the SVC connections on the given port has to be deleted." ::= { frPortCnfX21PortGrpEntry 16 } x21portIngrSvcBandW OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents Ingress Bandwidth reserve for SVC." ::= { frPortCnfX21PortGrpEntry 17 } x21portEgrSvcBandW OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This represents Egress Bandwidth reserve for SVC." ::= { frPortCnfX21PortGrpEntry 18 } -- ********************************************************************* -- x21AlmConfig group -- -- This group contains X.21/HSSI line alarm configuration table -- -- ********************************************************************* x21AlmCnfGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF X21AlmCnfGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The FRSM-HS1/HS2 interface alarm configuration table." ::= { x21AlmCnfGrp 1 } x21AlmCnfGrpEntry OBJECT-TYPE SYNTAX X21AlmCnfGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the X.21/HSSI Alarm Configuration table." INDEX { x21AlmCnfLineNum } ::= { x21AlmCnfGrpTable 1 } X21AlmCnfGrpEntry ::= SEQUENCE { x21AlmCnfLineNum Integer32, x21Severity INTEGER } x21AlmCnfLineNum OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "X.21/HSSI line number. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8." ::= { x21AlmCnfGrpEntry 1 } x21Severity OBJECT-TYPE SYNTAX INTEGER { minor(1), major(2), dontcare(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to setup the severity of LOS(Loss of Signal) or clock mismatch alarm. Whenever the above condition arises, the FRSM-HS1/HS2/HS2B will send the alarm with appropriate status." ::= { x21AlmCnfGrpEntry 2 } -- ********************************************************************* -- -- X.21/HSSI Alarm Group -- -- This group contains X.21/HSSI line alarm table -- -- ********************************************************************* x21AlmGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF X21AlmGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The X.21/HSSI interface alarm configuration table." ::= { x21AlmGrp 1 } x21AlmGrpEntry OBJECT-TYPE SYNTAX X21AlmGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the X21 Alarm table" INDEX { x21AlmLineNum } ::= { x21AlmGrpTable 1 } X21AlmGrpEntry ::= SEQUENCE { x21AlmLineNum Integer32, x21LineAlarmState Integer32, x21LineEIAStatus Integer32, x21AlarmClrButton INTEGER } x21AlmLineNum OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the identifier (line number) of a X.21/HSSI interface. The value for this object must be same as the value of x21LineNum." ::= { x21AlmGrpEntry 1 } x21LineAlarmState OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is a bitmap of the X21 Line ALarms on the FRSM-HS1. A value of zero indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 0 C/I signal is OFF (also used to indicate LOS) 1 Clock rate mismatch (used in DTE mode) 2 Internal Loopback (diagnostic loopback) 3 HSSI Local LoopA (line is in loopback) 4 HSSI Local LoopB (line is in loopback) 5 Remote Loopback (line is transmitting loopcodes) 6 For V35 DTE mode, DCD and CTS both are inactive 7 For V35 DCE mode, RTS is inactive 8 No cable attached to V35 backcard 9 Wrong cable attached to V35 backcard If all the bit-states are 0s: - line is not in alarm, or - line not in loopback, or - line is transmitting any loopback codes. " ::= { x21AlmGrpEntry 2 } x21LineEIAStatus OBJECT-TYPE SYNTAX Integer32 (0..'10'h) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the status of X.21/HSSI lines: 0x01 -- c-lead high 0x02 -- i-lead high 0x04 -- LC-lead high (valid only for HSSI DCE mode)." ::= { x21AlmGrpEntry 3 } x21AlarmClrButton OBJECT-TYPE SYNTAX INTEGER { noaction (1), clear (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to clear all the alarms for the line. 1 = No action 2 = Clear alarm." ::= { x21AlmGrpEntry 4 } -- conformance information cwfX21MIBConformance OBJECT IDENTIFIER ::= { ciscoWanFrX21MIB 2 } cwfX21MIBGroups OBJECT IDENTIFIER ::= { cwfX21MIBConformance 1 } cwfX21MIBCompliances OBJECT IDENTIFIER ::= { cwfX21MIBConformance 2 } -- compliance statements cwfX21Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for objects related to Frame Relay Ports." MODULE MANDATORY-GROUPS { ciscoWanFrX21LineGroup, ciscoWanFrX21PortGroup, ciscoWanFrX21AlarmConfGroup, ciscoWanFrX21AlarmGroup } ::= { cwfX21MIBCompliances 1 } ciscoWanFrX21PortGroup OBJECT-GROUP OBJECTS { x21portNum, x21portLineNum, x21portRowStatus, x21portFlagsBetweenFrames, x21portEqueueServiceRatio, x21portSpeed, x21portAdmin, x21portType, x21portSvcStatus, x21portSvcInUse, x21portSvcShareLcn, x21portSvcLcnLow, x21portSvcLcnHigh, x21portSvcDlciLow, x21portSvcDlciHigh, x21portDeleteSvcs, x21portIngrSvcBandW, x21portEgrSvcBandW } STATUS current DESCRIPTION "The collection of objects which are applicable for X21 ports in frame relay." ::= { cwfX21MIBGroups 1 } ciscoWanFrX21LineGroup OBJECT-GROUP OBJECTS { x21LineNum, x21LineEnable, x21LineType, x21LineRate, x21LineLoopbackCommand, x21LineSendCode, x21LineLoopbackCodeDetection, x21ConnectorType, x21InvertClock, x21LineInterfaceType, x21ClkFrequencyThreshold, serialLineRate, serialLineRateVariation, x21LineNumofValidEntries } STATUS current DESCRIPTION "The collection of objects which are related to x21 lines." ::= { cwfX21MIBGroups 2 } ciscoWanFrX21AlarmConfGroup OBJECT-GROUP OBJECTS { x21AlmCnfLineNum, x21Severity } STATUS current DESCRIPTION "The collection of objects which are related to x21 lines." ::= { cwfX21MIBGroups 3 } ciscoWanFrX21AlarmGroup OBJECT-GROUP OBJECTS { x21AlmLineNum, x21LineAlarmState, x21LineEIAStatus, x21AlarmClrButton } STATUS current DESCRIPTION "The collection of objects which are related to x21 lines." ::= { cwfX21MIBGroups 4 } END