SYNOPTICS-COMMON-MIB device MIB details by SynOptics
SYNOPTICS-COMMON-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing SYNOPTICS-COMMON-MIB.
Vendor: | SynOptics |
---|---|
Mib: | SYNOPTICS-COMMON-MIB [download] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
-- This file contains the concatenation of the following -- SynOptics MIB modules/files: -- com3.2-09.30.91 -- enet3.3-10.25.91 -- ieee802.3-1.0-09.30.91 -- tr3.1-10.25.91 -- traps1.0-09.30.91 -- file: com3.2-09.30.91 SYNOPTICS-COMMON-MIB -- Common MIB Release 3.2 -- DRAFT Revision 9/30/91 -- Printed 10/7/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS enterprises, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- Textual Conventions S3BackplaneType ::= INTEGER { other(1), -- none of the following ethernet(2), -- ethernet ethernetTokenRing(3), -- ethernet and token ring ethernetFddi(4), -- ethernet and FDDI ethernetTokenRingFddi(5), -- ethernet, token ring, and FDDI ethernetTokenRingRedundant(6), -- redundant backplane ethernetTokenRingFddiRedund(7) -- redundant backplane } -- This type is used to specify a concentrator backplane. S3ChassisType ::= INTEGER { other(1), -- none of the following m3000(2), -- model 3000 m3030(3), -- model 3030 m2310(4), -- model 2310 m2810(5) -- model 2810 } -- This type is used to specify a concentrator chassis. S3ModuleType ::= INTEGER { empty(1), -- nothing installed other(2), -- none of the following m3302(3), -- STP ethernet Host Module m3304-ST(4), -- FOIRL ethernet Host Module m3305(5), -- UTP ethernet Host Module m3308(6), -- 10 base-T ethernet Host Module m3313(7), -- AUI ethernet NMM w/ RS232 port m3313M(8), -- AUI ethernet NMM w/ RS232 + modem m3314-ST(9), -- FOIRL ethernet NMM w/ RS232 m3314M-ST(10), -- FOIRL ethernet NMM w/ RS232 + modem m3323(11), -- AUI Local Bridge m3324-ST(12), -- FOIRL Local Bridge m3502(13), -- STP Token Ring Host Module m3532(14), -- STP Token Ring Repeater m3552(15), -- STP Ring in/ Ring out Module m3301(16), -- Thin Net ethernet Host Module m3307(17), -- 10 base-T 50 pin Host Module m3356(18), -- Ethernet Remote Bridge m3512(19), -- T.R. NMM w/ STP ring in/ring out m3514(20), -- T.R. NMM w/ FOIRL ring in/ring out m3505(21), -- UTP Token Ring Host Module m3554(22), -- FOIRL ring in/ring out Module m3534(23), -- FOIRL Repeater m3383(24), -- AUI ethernet Local Router m3384(25), -- FOIRL ethernet Local Router m331x(26), -- ethernet NMM module w/unknown MDA type m351x(27), -- t.r. NMM module w/unknown MDA type m3502-A(28), -- STP Token Ring Host Module m3902(29), -- STP FDDI Host Module m3904(30), -- Fiber FDDI Host Module m3910S(31), -- FDDI Super NMM m3386(32), -- Cisco Remote Router m3394(33), -- Ethernet-localtalk router m3395(34), -- XYPLEX terminal server m3323S(35), -- High Speed Local Bridge with AUI m3324S-ST(36), -- High Speed Local Bridge with FOIRL m3307A(37), -- 10baseT with amp connector m3308A(38), -- 10baseT (Ibid) m3505A(39), -- UTP Token Ring Host Module m3513(40), -- STP TR repeater NMM m3333(41), -- ethernet retiming module AUI m3334-ST(42), -- ethernet retiming module FOIRL m3040(43), -- model 3040 NCE (SPARCStation on a card) m3100R(44), -- 3100R Summing Module m2810-hm(47), -- host part of 2810 non-modular Ethernet m2810-nmm(48) -- nmm part of 2810 non-modular Ethernet } -- This type is used to specify a module. S3PsType ::= INTEGER { other(1), -- none of the following low(2), -- 200 watt supply (3000) -- 50 watt supply (2810) medium(3), -- 360 watt supply (3000) -- 110 watt supply (3030) high(4), -- 460 watt supply (3000) -- 150 watt supply (3030) redundantCapable(5) -- redundant backplane (3000) } -- This type is used to specify the power supply type. Where used, the -- descriptions specify the valid values. -- Categories synoptics OBJECT IDENTIFIER ::= { enterprises 45 } products OBJECT IDENTIFIER ::= { synoptics 1 } temporary OBJECT IDENTIFIER ::= { synoptics 2 } registration OBJECT IDENTIFIER ::= { synoptics 3 } -- Groups series1000 OBJECT IDENTIFIER ::= { products 1 } s3SnmpAgent OBJECT IDENTIFIER ::= { products 2 } series3000 OBJECT IDENTIFIER ::= { products 3 } ieee8023 OBJECT IDENTIFIER ::= { temporary 1 } s3000Chassis OBJECT IDENTIFIER ::= { series3000 1 } s3000Ethernet OBJECT IDENTIFIER ::= { series3000 2 } s3000TokenRing OBJECT IDENTIFIER ::= { series3000 3 } s3000FDDI OBJECT IDENTIFIER ::= { series3000 4 } s3000Bridge OBJECT IDENTIFIER ::= { series3000 5 } s3000TerminalServer OBJECT IDENTIFIER ::= { series3000 6 } s3AgentSw OBJECT IDENTIFIER ::= { s3SnmpAgent 1 } s3AgentNetProtocol OBJECT IDENTIFIER ::= { s3SnmpAgent 2 } -- this one is defined in section 4. -- s3AgentTrapReceiverTable OBJECT IDENTIFIER ::= { s3SnmpAgent 3 } s3AgentHw OBJECT IDENTIFIER ::= { s3SnmpAgent 4 } s3AgentSpecific OBJECT IDENTIFIER ::= { s3SnmpAgent 5 } s3AgentLocImage OBJECT IDENTIFIER ::= { s3SnmpAgent 6 } s3AgentIpProtocol OBJECT IDENTIFIER ::= { s3AgentNetProtocol 1 } -- Products -- These object identifiers are for use as values for sysObjectId. s3reg-other OBJECT IDENTIFIER ::= { registration 1 } s3reg-3000 OBJECT IDENTIFIER ::= { registration 2 } s3reg-3000-enetNMM OBJECT IDENTIFIER ::= { s3reg-3000 1 } s3reg-3000-trNMM OBJECT IDENTIFIER ::= { s3reg-3000 2 } s3reg-3000-FDDI-NMM OBJECT IDENTIFIER ::= { s3reg-3000 3 } s3reg-3030 OBJECT IDENTIFIER ::= { registration 3 } s3reg-3030-enetNMM OBJECT IDENTIFIER ::= { s3reg-3030 1 } s3reg-3030-trNMM OBJECT IDENTIFIER ::= { s3reg-3030 2 } s3reg-3030-FDDI-NMM OBJECT IDENTIFIER ::= { s3reg-3030 3 } s3reg-2310 OBJECT IDENTIFIER ::= { registration 4 } s3reg-2310-enetNMM OBJECT IDENTIFIER ::= { s3reg-2310 1 } s3reg-332X OBJECT IDENTIFIER ::= { registration 5 } s3reg-332XS OBJECT IDENTIFIER ::= { registration 6 } s3reg-3356 OBJECT IDENTIFIER ::= { registration 7 } s3reg-2810 OBJECT IDENTIFIER ::= { registration 8 } s3reg-2810-enetNMM OBJECT IDENTIFIER ::= { s3reg-2810 1 } -- SECTION 2: Concentrator Chassis -- Chassis Group -- Implementation of this group is mandatory for all SynOptics Series 3000 -- agents. s3ChassisType OBJECT-TYPE SYNTAX S3ChassisType ACCESS read-only STATUS mandatory DESCRIPTION "The chassis type." ::= { s3000Chassis 1 } s3ChassisBkplType OBJECT-TYPE SYNTAX S3BackplaneType ACCESS read-only STATUS mandatory DESCRIPTION "The chassis backplane type." ::= { s3000Chassis 2 } s3ChassisBkplRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The chassis backplane revision." ::= { s3000Chassis 3 } s3ChassisPsType OBJECT-TYPE SYNTAX S3PsType ACCESS read-only STATUS mandatory DESCRIPTION "The chassis power supply type." ::= { s3000Chassis 4 } s3ChassisPsStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- supply ok primaryFail(2), -- primary power supply failure secondaryFail(3), -- secondary power supply failure bothFail(4) -- both power supplies failed } ACCESS read-only STATUS mandatory DESCRIPTION "The chassis power supply status." ::= { s3000Chassis 5 } s3ChassisFanStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- fans are running fail(2), -- fan(s) are broken other(3) -- unknown fan status or no fan } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the chassis cooling fan." ::= { s3000Chassis 6 } -- Chassis Slot Configuration Table s3SlotConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF S3SlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The chassis slot configuration table." ::= { s3000Chassis 7 } s3SlotConfigEntry OBJECT-TYPE SYNTAX S3SlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "What type of module is in each slot of the chassis." INDEX { s3SlotNumber } ::= { s3SlotConfigTable 1 } S3SlotConfigEntry ::= SEQUENCE { s3SlotNumber INTEGER, s3SlotModuleId INTEGER, s3SlotModuleType S3ModuleType, s3SlotModuleDescr DisplayString, s3SlotModuleLed OCTET STRING, s3SlotModuleMdaId INTEGER } s3SlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The 3000 Chassis slot number. Valid entries are 1-12." ::= { s3SlotConfigEntry 1 } s3SlotModuleId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ID for the module." ::= { s3SlotConfigEntry 2 } s3SlotModuleType OBJECT-TYPE SYNTAX S3ModuleType ACCESS read-only STATUS deprecated DESCRIPTION "The type of module this entry represents." ::= { s3SlotConfigEntry 3 } s3SlotModuleDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Module description." ::= { s3SlotConfigEntry 4 } s3SlotModuleLed OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "Status of the module LEDs." ::= { s3SlotConfigEntry 5 } s3SlotModuleMdaId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ID of the medium-dependent part of the board. The value is board dependent." ::= { s3SlotConfigEntry 6 } -- Chassis Common Board Table s3CommonBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF S3CommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about the boards currently plugged into the 3000 Chassis. This board table contains an entry for each non-empty slot in the s3SlotConfigTable, EXCEPT for those slots containing Retiming Modules. All of the information in this board table is retrievable using the NMI commands that are common to all boards integrated into the SynOptics Series 3000 Concentrators." ::= { s3000Chassis 8 } s3CommonBoardEntry OBJECT-TYPE SYNTAX S3CommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table entry containing information about a single Board currently plugged into the 3000 Chassis. These values can be retrieved using the common board NMI commands." INDEX { s3CommonBoardIndex } ::= { s3CommonBoardTable 1 } S3CommonBoardEntry ::= SEQUENCE { s3CommonBoardIndex INTEGER, s3CommonBoardId INTEGER, s3CommonBoardHwVer INTEGER, s3CommonBoardStatus INTEGER, s3CommonBoardReset INTEGER, s3CommonBoardPartStatus INTEGER, s3CommonBoardNmCntlStatus INTEGER, s3CommonBoardPsStatus INTEGER } s3CommonBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3CommonBoardEntry 1 } s3CommonBoardId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ID of the board." ::= { s3CommonBoardEntry 2 } s3CommonBoardHwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The hardware revision of the board. 0=Rev. A, 1=Rev. B, etc." ::= { s3CommonBoardEntry 3 } s3CommonBoardStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- good status fail(2) -- bad status } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the operational status of the board." ::= { s3CommonBoardEntry 4 } s3CommonBoardReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), -- not resetting reset(2) -- resetting } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates the reset state of the board. Writing with the value reset (2) will reset the board." ::= { s3CommonBoardEntry 5 } s3CommonBoardPartStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- board enabled partition(2) -- board partitioned indefinitely } ACCESS read-write STATUS mandatory DESCRIPTION "Tells whether the board is partitioned or enabled. Writing with the value partition(2) will partition the board indefinitely and writing with the value enabled(1) will enable the board. Boards cannot be partitioned in the 2810 concentrator. The 2810 agent will implement this object as read-only." ::= { s3CommonBoardEntry 6 } s3CommonBoardNmCntlStatus OBJECT-TYPE SYNTAX INTEGER { notNmControl(1), -- board not under NM control nmControl(2) -- board under NM control } ACCESS read-only STATUS mandatory DESCRIPTION "Tells whether the board is under network management control. The value nmControl(2) indicates that the board or one or more ports are being controlled by network management. This means that the board or one or more ports are partitioned via a network manager." ::= { s3CommonBoardEntry 7 } s3CommonBoardPsStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- good status fail(2) -- bad status } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the operational status of the board power supply. A fail(2) indicates that one of the power supplies on the board has failed." ::= { s3CommonBoardEntry 8 } -- Packed Slot Configuration Table s3SlotConfigOctetString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12..144)) ACCESS read-only STATUS mandatory DESCRIPTION "Packed octet string for the slot configuration table." ::= { s3000Chassis 9 } -- SECTION 3: Agent Configuration -- Agent Software Group -- Implementation of this group is mandatory for all SynOptics Series 3000 -- agents s3AgentType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following m3313(2), -- AUI Ethernet NMM w/ RS232 port m3313M(3), -- AUI Enet NMM w/ RS232 port + modem m3314-ST(4), -- FOIRL Ethernet NMM w/ RS232 m3314M-ST(5), -- FOIRL Ethernet NMM w/ RS232 + modem m2310(6), -- Model 2310 m3512(7), -- T.R. NMM w/ STP ring in/ring out m3514(8), -- T.R. NMM w/ FOIRL ring in/ring out m332X(9), -- Low Speed Local Bridge m3356(10), -- Ethernet Remote Bridge m332XS(11) -- High Speed Local Bridge } ACCESS read-only STATUS mandatory DESCRIPTION "The 3000 series agent's Module type." ::= {s3AgentSw 1 } s3AgentFwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The agent's module firmware version 0=Rev A,1=Rev B,etc." ::= { s3AgentSw 2 } s3AgentSwMajorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The network management module major software version number (i.e. represents major.minor or 3.0). Object is in decimal." ::= { s3AgentSw 3 } s3AgentSwMinorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The network management module minor software version number (i.e. represents major.minor or 3.0). Object is in decimal." ::= { s3AgentSw 4 } s3AgentBootProtocol OBJECT-TYPE SYNTAX INTEGER { other(1), -- boot protocol not listed here bootp-tftp(2), tftp-only(3), ieee802-1e(4), proprietary(5), -- supported proprietary boot protocol dll-download(6) -- direct async binary download (Retix) } ACCESS read-only STATUS mandatory DESCRIPTION "Boot protocol used to load the module with its software." ::= {s3AgentSw 5 } s3AgentBootFile OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the boot file that is sent to the file server during boot time. The actual boot protocol used to retrieve the file is determined by s3AgentBootProtocol. This parameter will not take effect until written into EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset) is issued. This parameter is used only if the s3AgentBootMode is set to use EEPROM." ::= { s3AgentSw 6 } s3AgentAuthTrap OBJECT-TYPE SYNTAX INTEGER { disable(1), -- disable authentication traps enable(2) -- enable authentication traps } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the use of authentication error trap generation. This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless the specific NMM configuration file is updated to reflect the change." ::= { s3AgentSw 7 } s3AgentLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "This is a informational string that could be used to show the physical location (i.e. area) of the NMM or concentrator. This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless the specific NMM configuration file is updated to reflect the change." ::= { s3AgentSw 8 } s3AgentMibLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used to determine current MIB release supported by agent. The encoding of this object is of the following form: xyy, where x is the major version number and yy is the minor version number. Thus, version 3.0 would be represented as 300, version 3.01 would be 301 and 3.1 would be 310. Object is in decimal." ::= { s3AgentSw 9 } s3AgentFeatureLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used to determine feature level of the agent. The encoding of this object is of the following form: xyy, where x is the major version number and yy is the minor version number. Thus, feature level version 1.0 would be represented as 100, version 1.01 would be 101 and 1.1 would be 110. Object is in decimal." ::= { s3AgentSw 10 } s3AgentMySlotId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot where this agent currently resides. If hardware is unable to determine then a 0 should be returned." ::= { s3AgentSw 11 } -- Agent Network Protocol Group -- Implementation of this group is mandatory for all SynOptics Series 3000 -- agents. s3AgentIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The network management module's administrative IP address. The current operational IP address can be obtained by the ipAdEntAddr entry in the ipAddrTable. This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless it is written into EEPROM (s3AgentWriteEeprom). This parameter is used only if the s3AgentBootMode is set to use EEPROM." ::= { s3AgentIpProtocol 1 } s3AgentNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The network management module's administrative subnet mask. The current operational subnet mask can be obtained by the ipAdEntNetMask entry in the ipAddrTable. This parameter will ` take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless it is written into EEPROM (s3AgentWriteEeprom). This parameter is used only if the agentBootMode is set to use EEPROM. NOTE: The Model 331x (3313, 3313M, 3314-ST, 3314M-ST) Ethernet NMM agents do not store this parameter in EEPROM, so for these agents the subnet mask configuration must be downloaded in the configuration file." ::= { s3AgentIpProtocol 2 } s3AgentDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The network management module's administrative default gateway IP address. The current operational default gateway's IP address can be obtained from the ipRoutingTable. This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless it is written into EEPROM (s3AgentWriteEeprom). This parameter is used only if the agentBootMode is set to use EEPROM." ::= { s3AgentIpProtocol 3 } s3AgentBootServerAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address to which the requests for boot files are sent. The protocol used to retrieve the boot files is determined by object s3AgentBootProtocol. This parameter will not take effect until until written into EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset) is issued. This parameter is used only if the s3AgentBootMode is set to use EEPROM." ::= { s3AgentIpProtocol 4 } -- Agent Trap Receiver Table -- Implementation of this group is mandatory for all SynOptics Series 3000 agents s3AgentTrapReceiverTable OBJECT-TYPE SYNTAX SEQUENCE OF S3AgentTrapReceiverEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing list of NMS's that are to receive traps generated by this NMM." ::= { s3SnmpAgent 3 } s3AgentTrapReceiverEntry OBJECT-TYPE SYNTAX S3AgentTrapReceiverEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A destination address and community string to a particular trap server, along with a trap filter and entry aging capability." INDEX { s3AgentTrapRcvrNetAddress } ::= { s3AgentTrapReceiverTable 1 } S3AgentTrapReceiverEntry ::= SEQUENCE { s3AgentTrapRcvrStatus INTEGER, s3AgentTrapRcvrNetAddress OCTET STRING, s3AgentTrapRcvrComm OCTET STRING, s3AgentTrapRcvrAgeTime TimeTicks } s3AgentTrapRcvrStatus OBJECT-TYPE SYNTAX INTEGER { other (1), -- none of the following valid (2), -- a valid address invalid (3) -- an invalid address } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to the value invalid(3) has the effect of invalidating the corresponding entry in the s3AgentTrapReceiverTable. That is, it effectively disassociates the address identified with the entry by removing the entry from the table. On a read the value of valid(2) should be returned if the entry contains a valid record, or invalid(3) should be returned if the entry contains an invalid record." ::= { s3AgentTrapReceiverEntry 1 } s3AgentTrapRcvrNetAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "IP address for trap server that is to receive the trap." ::= { s3AgentTrapReceiverEntry 2 } s3AgentTrapRcvrComm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "Community string used for traps sent to this trap receiver." ::= { s3AgentTrapReceiverEntry 3 } s3AgentTrapRcvrAgeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "This is the time interval used to age entries out of the trap receiver table. The default value if not specified will be 0, or infinite, never to be aged out." ::= { s3AgentTrapReceiverEntry 4 } -- Agent Hardware Group -- Implementation of this group is mandatory for all SynOptics Series 3000 -- agents. s3AgentStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), -- the agent is offline online(2) -- the agent is online } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the NMM is online(2) and operating, or offline(1) (ie: not connected to the concentrator backplane)." ::= { s3AgentHw 1 } s3AgentMdaHwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The network management module's MDA hardware version number (0=Rev. A, 1=Rev. B, etc.)." ::= { s3AgentHw 2 } s3AgentMode OBJECT-TYPE SYNTAX INTEGER { primary(1), -- in primary mode secondary(2), -- in secondary mode other(3) -- the other values do not apply } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates whether the NMM is operating in primary(1) or secondary(2) mode." ::= { s3AgentHw 3 } s3AgentReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), -- not resetting reset(2) -- reset } ACCESS read-write STATUS mandatory DESCRIPTION "Network management module reset status. Writing a reset(2) to this object will reset the NMM (stop refreshing the watch dog) and perform a download and restart. This process takes about 45 seconds." ::= { s3AgentHw 4 } s3AgentRestart OBJECT-TYPE SYNTAX INTEGER { noRestart(1), -- not restarting restart(2) -- restart } ACCESS read-write STATUS mandatory DESCRIPTION "Network management module restart status. Writing a restart(2) to this object will restart the NMM. This initializes all the counters, re-reads the EEPROM data structure and starts executing from the beginning of the code." ::= { s3AgentHw 5 } s3AgentBootMode OBJECT-TYPE SYNTAX INTEGER { eeprom(1), -- get boot info from eeprom other(2) -- or from a boot protocol } ACCESS read-write STATUS mandatory DESCRIPTION "The method for obtaining boot parameter information. This parameter will not take effect until written into EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset) is issued." ::= { s3AgentHw 6 } s3AgentWriteEeprom OBJECT-TYPE SYNTAX INTEGER { noWriteEeprom(1), -- not writing EEPROM writeEeprom(2) -- write EEPROM } ACCESS read-write STATUS mandatory DESCRIPTION "Network management module EEPROM write status. Writing a (2) to this object will write the contents of current EEPROM data structure in the EEPROM." ::= { s3AgentHw 7 } s3AgentBaudRate OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the baud rate in bits per second of either the internal modem or the RS-232 port. This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless the specific NMM configuration file is updated to reflect the change." ::= { s3AgentHw 8 } s3AgentInitString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the initialization string used to establish the out-of-band connection. (i.e. could contain the string ATDT,415-960-1100 for an internal or external modem). This parameter will take effect only after a restart (s3AgentRestart) is issued. This parameter will not survive a reset (s3AgentReset) unless the specific NMM configuration file is updated to reflect the change." ::= { s3AgentHw 9 } -- Agent Local Image Group -- This group is mandatory for agents with image code stored in local EPROM. -- Other agents should return NoSuch if asked for any of the objects in this group. s3LocImageValid OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status localImageValid(2), -- local image is valid localImageInvalid(3) -- local image is invalid } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the agent has a valid local code image on board. An EPROM checksum failure would cause the agent to return localImageInvalid(3)." ::= { s3AgentLocImage 1 } s3LocImageMajorVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The major software version number of the locally-stored image. This object applies only to agents with valid local image. Other agents should return zero." ::= { s3AgentLocImage 2 } s3LocImageMinorVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minor software version number of the locally-stored image. This object applies only to agents with valid local image. Other agents should return zero." ::= { s3AgentLocImage 3 } s3LocImageLoadMode OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status remoteBoot(2), -- use net, not local image localBoot(3), -- boot from local image, not net localAsBackup(4) -- try net, if fails use local } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates whether the agent should get code from the network, use a local image, or try the network first and then fall back to local image if the network boot fails. The localBoot and localAsBackup values apply only to agents with local load option." ::= { s3AgentLocImage 4 } s3LocImageActualSource OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status remoteImage(2), -- downloaded code from network localImage(3) -- loaded code from local EPROM } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the agent loaded code from the network or used a local image. When the the ImageLoadMode is localAsBackup, this variable indicates whether the network load was successful." ::= { s3AgentLocImage 5 } END -- file: enet3.3-10.25.91 SYNOPTICS-ETHERNET-MIB -- Ethernet MIB Release 3.3 -- DRAFT Revision 10/25/91 -- Printed 10/25/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS Counter, IpAddress, Gauge FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 s3000Ethernet FROM SYNOPTICS-COMMON-MIB; -- Groups s3000EnetConcentrator OBJECT IDENTIFIER ::= { s3000Ethernet 1 } s3000EnetBoard OBJECT IDENTIFIER ::= { s3000Ethernet 2 } s3000EnetLocBridge OBJECT IDENTIFIER ::= { s3000EnetBoard 2 } s3000EnetRemBridge OBJECT IDENTIFIER ::= { s3000EnetBoard 3 } s3000EnetRouter OBJECT IDENTIFIER ::= { s3000EnetBoard 4 } s3000EnetPort OBJECT IDENTIFIER ::= { s3000Ethernet 3 } s3000EnetNmm OBJECT IDENTIFIER ::= { s3000Ethernet 4 } -- SECTION 2: Ethernet Status and Statistics Group -- The Ethernet Status and Statistics group consists of Concentrator Group, -- Board Table, Local Bridge Board Table, Local Bridge Port Table, -- Remote Bridge Board Table, Remote Bridge Port Table, Router Board -- Table, and Port Table. -- Concentrator Group -- Implementation of this group is mandatory for all -- SynOptics Series 3000 Ethernet NMM agents s3EnetConcRetimingStatus OBJECT-TYPE SYNTAX INTEGER { off(1), -- retiming off on(2) -- retiming on } ACCESS read-write STATUS mandatory DESCRIPTION "Does this concentrator have retiming turned on. Writing a 1 will turn off retiming and writing a 2 will turn on retiming. This will change the active state of retiming but will change the value in EEPROM only when agentWriteEeprom is set.The factory default of this state is on. Retiming cannot be disabled in the 2810 concentrator. The 2810 agent will implement this object as read-only." ::= { s3000EnetConcentrator 1 } s3EnetConcFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the concentrator. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received." ::= { s3000EnetConcentrator 2 } s3EnetConcOctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Contains a count of data and padding octets in frames that are successfully received by the concentrator. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received. This counter does not include the octets in the address, length/type and CRC fields." ::= { s3000EnetConcentrator 3 } s3EnetConcMcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the concentrator and are directed to an active non-broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Only frames that are for a multicast address that this interface is receiving are counted. Broadcast packets are not included." ::= { s3000EnetConcentrator 4 } s3EnetConcBcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the concentrator and are directed to the broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Multicast packets are not included." ::= { s3000EnetConcentrator 5 } s3EnetConcColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of the collision flags at the concentrator level." ::= { s3000EnetConcentrator 6 } -- MAC Receive Error Statistics -- A hierarchical order has been established for those objects listed below -- such that when multiple error conditions can be associated with one frame, -- only one condition is counted. This hierarchy, in descending order is: -- frame too long -- runt frames -- fragments -- alignment error -- frame check error s3EnetConcTooLongErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are received by the concentrator and exceed the maximum permitted frame size. This counter is incremented when the frameTooLong error is detected." ::= { s3000EnetConcentrator 7 } s3EnetConcRuntErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the concentrator that are less than the minimum permitted frame size and have a good FCS." ::= { s3000EnetConcentrator 8 } s3EnetConcFragErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the concentrator that are less than the minimum permitted frame size and have a bad FCS or alignment error." ::= { s3000EnetConcentrator 9 } s3EnetConcAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the concentrator that are not an integral number of octets in length and do not pass the FCS check. This counter is incremented when the alignment Error status is detected." ::= { s3000EnetConcentrator 10 } s3EnetConcFcsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the concentrator that are an integral number of octets in length that do not pass the FCS check. This counter is incremented when the frame Check Error status is detected." ::= { s3000EnetConcentrator 11 } s3EnetConcLateCollErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a total concentrator count of the late collision flags." ::= { s3000EnetConcentrator 12 } -- Board Table s3EnetBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of board-related objects. The number of entries is given by the number of Ethernet host module and network management module boards that are contained in the Concentrator Slot Configuration Table." ::= { s3000EnetBoard 1 } s3EnetBoardEntry OBJECT-TYPE SYNTAX S3EnetBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about Ethernet boards which are currently plugged into the 3000 chassis." INDEX { s3EnetBoardIndex } ::= { s3EnetBoardTable 1 } S3EnetBoardEntry ::= SEQUENCE { s3EnetBoardIndex INTEGER, -- the bounded below objects are deprecated s3EnetBoardType INTEGER, s3EnetBoardHwVer INTEGER, s3EnetBoardStatus INTEGER, s3EnetBoardReset INTEGER, s3EnetBoardPartStatus INTEGER, s3EnetBoardNmCntlStatus INTEGER, s3EnetBoardPsStatus INTEGER, -- the bounded above objects are deprecated s3EnetBoardFrmsRxOk Counter, s3EnetBoardOctetsRxOk Counter, s3EnetBoardMcastFrmsRxOk Counter, s3EnetBoardBcastFrmsRxOk Counter, s3EnetBoardColls Counter, s3EnetBoardTooLongErrors Counter, s3EnetBoardRuntErrors Counter, s3EnetBoardAlignErrors Counter, s3EnetBoardFcsErrors Counter, s3EnetBoardLateCollErrors Counter } s3EnetBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetBoardEntry 1 } s3EnetBoardType OBJECT-TYPE SYNTAX INTEGER { empty(1), -- nothing installed other(2), -- none of the following m3302(3), -- Model 3302 m3304-ST(4), -- Model 3304-ST m3305(5), -- Model 3305 m3308(6), -- Model 3308 m3313(7), -- Model 3313 m3313M(8), -- Model 3313M m3314-ST(9), -- Model 3314 m3314M-ST(10), -- Model 3314M-ST m3323(11), -- Model 3323 m3324-ST(12), -- Model 3324-ST m3301(16), -- Model 3301 m3307(17), -- Model 3307 m3356(18), -- Model 3356 m3383(24), -- Model 3383 m3384(25), -- Model 3384 m331x(26), -- unknown 331x m3386(32), -- Model 3386 m3394(33), -- Model 3394 m3395(34), -- Model 3395 m3323S(35), -- Model 3323S m3324S-ST(36), -- Model 3324S-ST m3307A(37), -- Model 3307A m3308A(38) -- Model 3308A } ACCESS read-only STATUS deprecated DESCRIPTION "See s3SlotModuleType" ::= { s3EnetBoardEntry 2 } s3EnetBoardHwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "See s3CommonBoardHwVer" ::= { s3EnetBoardEntry 3 } s3EnetBoardStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- good status fail(2) -- bad status } ACCESS read-only STATUS deprecated DESCRIPTION "See s3CommonBoardStatus" ::= { s3EnetBoardEntry 4 } s3EnetBoardReset OBJECT-TYPE SYNTAX INTEGER { noReset(1), -- not resetting reset(2) -- resetting } ACCESS read-write STATUS deprecated DESCRIPTION "See s3CommonBoardReset" ::= { s3EnetBoardEntry 5 } s3EnetBoardPartStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- board enabled partition(2) -- board partitioned } ACCESS read-write STATUS deprecated DESCRIPTION "See s3CommonBoardPartStatus" ::= { s3EnetBoardEntry 6 } s3EnetBoardNmCntlStatus OBJECT-TYPE SYNTAX INTEGER { notNmControl(1), -- board not under NM control nmControl(2) -- board under NM control } ACCESS read-only STATUS deprecated DESCRIPTION "See s3CommonBoardCntlStatus" ::= { s3EnetBoardEntry 7 } s3EnetBoardPsStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), -- good status fail(2) -- bad status } ACCESS read-only STATUS deprecated DESCRIPTION "See s3CommonBoardPsStatus" ::= { s3EnetBoardEntry 8 } s3EnetBoardFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the board. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received." ::= { s3EnetBoardEntry 9 } s3EnetBoardOctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Contains a count of data and padding octets in frames that are successfully received by the board. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received. This counter does not include the octets in the address, length/type and CRC fields." ::= { s3EnetBoardEntry 10 } s3EnetBoardMcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the board and are directed to an active non-broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Only frames that are for a multicast address that this interface is receiving are counted. Broadcast packets are not included." ::= { s3EnetBoardEntry 11 } s3EnetBoardBcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the board and are directed to the broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Multicast packets are not included." ::= { s3EnetBoardEntry 12 } s3EnetBoardColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a board level count of the collision flags. This is a summation of all the port level collision flag counters for this board." ::= { s3EnetBoardEntry 13 } -- MAC Receive Error Statistics -- A hierarchical order has been established for those objects listed below -- such that when multiple error condition can be associated with one frame, -- only one condition is counted. This hierarchy, in descending order is: -- frame Too Long -- runt frames -- alignment Error -- frame Check Error s3EnetBoardTooLongErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are received by the board and exceed the maximum permitted frame size. This counter is incremented when the frameTooLong error is detected." ::= { s3EnetBoardEntry 14 } s3EnetBoardRuntErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the board that are less than the minimum permitted frame size and have a good FCS." ::= { s3EnetBoardEntry 15 } s3EnetBoardAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the board that are not an integral number of octets in length and do not pass the FCS check. This counter is incremented when the alignmentError status is detected." ::= { s3EnetBoardEntry 16 } s3EnetBoardFcsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the board that are an integral number of octets in length that do not pass the FCS check. This counter is incremented when the frameCheckError status is detected." ::= { s3EnetBoardEntry 17 } s3EnetBoardLateCollErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of the board level late collision flags. This is a summation of all the port level late collision flag counters for this board." ::= { s3EnetBoardEntry 18 } -- Local Bridge Board Table s3EnetLocBridgeSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetLocBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Local Bridge Board entries. The number of entries is determined by the Concentrator Slot Configuration Table. Only those entries that are Ethernet local bridges will have entries in this list." ::= { s3000EnetLocBridge 1 } s3EnetLocBridgeEntry OBJECT-TYPE SYNTAX S3EnetLocBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about Boards which are local bridges that are currently plugged into the 3000 chassis." INDEX { s3EnetLocBridgeIndex } ::= { s3EnetLocBridgeSlotTable 1 } S3EnetLocBridgeEntry ::= SEQUENCE { s3EnetLocBridgeIndex INTEGER, s3EnetLocBridgeDescr DisplayString, s3EnetLocBridgePortCount INTEGER, s3EnetLocBridgeDiagSts OCTET STRING, s3EnetLocBridgeBootSts INTEGER, s3EnetLocBridgeStandbySts INTEGER } s3EnetLocBridgeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetLocBridgeEntry 1 } s3EnetLocBridgeDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of the local bridge board." ::= { s3EnetLocBridgeEntry 2 } s3EnetLocBridgePortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of ports that are on the local bridge board." ::= { s3EnetLocBridgeEntry 3 } s3EnetLocBridgeDiagSts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Latest Diagnostic LED Status that has been recorded." ::= { s3EnetLocBridgeEntry 4 } s3EnetLocBridgeBootSts OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown booting status reqstToBoot(2), -- board is requesting to boot notReqstToBoot(3) -- board is not requesting to boot } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the board as it relates to rebooting." ::= { s3EnetLocBridgeEntry 5 } s3EnetLocBridgeStandbySts OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown booting status standby(2), -- bridge is in standby mode notStandby(3) -- bridge is operational and not standby } ACCESS read-only STATUS mandatory DESCRIPTION "This status says whether the local bridge is active or in standby mode." ::= { s3EnetLocBridgeEntry 6 } -- Local Bridge Port Table s3EnetLocBridgePortTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetLocBridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Port entries that are part of a local bridge. The number of entries is determined by knowing the number of local bridge boards that are installed by looking at s3ChassisSlotConfigTable and by knowing how many ports are on a local bridge board by looking at s3EnetLocBridgePortCount." ::= { s3000EnetLocBridge 2 } s3EnetLocBridgePortEntry OBJECT-TYPE SYNTAX S3EnetLocBridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about the ports of the local bridges that are currently plugged into the 3000 chassis." INDEX { s3EnetLocBridgePortSlotIndex, s3EnetLocBridgePortIndex } ::= { s3EnetLocBridgePortTable 1 } S3EnetLocBridgePortEntry ::= SEQUENCE { s3EnetLocBridgePortSlotIndex INTEGER, s3EnetLocBridgePortIndex INTEGER, s3EnetLocBridgePortMdaId INTEGER, s3EnetLocBridgePortIf INTEGER, s3EnetLocBridgePortDescr DisplayString, s3EnetLocBridgePortOpSts INTEGER } s3EnetLocBridgePortSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetLocBridgePortEntry 1 } s3EnetLocBridgePortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each port. Its value ranges between 1 and 12. The value for each port must remain constant at least from one reinitialization of the entity's network management system to the next reinitialization." ::= { s3EnetLocBridgePortEntry 2 } s3EnetLocBridgePortMdaId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Medium dependent ID for the port." ::= { s3EnetLocBridgePortEntry 3 } s3EnetLocBridgePortIf OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown interfaces etherEther(2), -- ethernet to ethernet bridge etherTokenRing(3) -- ethernet to token ring bridge } ACCESS read-only STATUS mandatory DESCRIPTION "Bridge interface types." ::= { s3EnetLocBridgePortEntry 4 } s3EnetLocBridgePortDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the port." ::= { s3EnetLocBridgePortEntry 5 } s3EnetLocBridgePortOpSts OBJECT-TYPE SYNTAX INTEGER { other(1), standby(2), notStandby(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Operating status of the port." ::= { s3EnetLocBridgePortEntry 6 } -- Remote Bridge Board Table s3EnetRemBridgeSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetRemBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Remote Bridge Board entries. The number of entries is determined by the Concentrator Slot Configuration Table. Only those entries that are Ethernet remote bridges will have entries in this list." ::= { s3000EnetRemBridge 1 } s3EnetRemBridgeEntry OBJECT-TYPE SYNTAX S3EnetRemBridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about Boards which are remote bridges that are currently plugged into the 3000 chassis." INDEX { s3EnetRemBridgeIndex } ::= { s3EnetRemBridgeSlotTable 1 } S3EnetRemBridgeEntry ::= SEQUENCE { s3EnetRemBridgeIndex INTEGER, s3EnetRemBridgeDescr DisplayString , s3EnetRemBridgePortCount INTEGER, s3EnetRemBridgeDiagSts OCTET STRING, s3EnetRemBridgeBootSts INTEGER, s3EnetRemBridgeStandbySts INTEGER } s3EnetRemBridgeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetRemBridgeEntry 1 } s3EnetRemBridgeDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of the board." ::= { s3EnetRemBridgeEntry 2 } s3EnetRemBridgePortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of ports that are on the board." ::= { s3EnetRemBridgeEntry 3 } s3EnetRemBridgeDiagSts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Latest Diagnostic LED Status that has been recorded." ::= { s3EnetRemBridgeEntry 4 } s3EnetRemBridgeBootSts OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown booting status reqstToBoot(2), -- board is requesting to boot notReqstToBoot(3) -- board is not requesting to boot } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the board as it relates to rebooting." ::= { s3EnetRemBridgeEntry 5 } s3EnetRemBridgeStandbySts OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown booting status standby(2), -- remote bridge is in standby mode notStandby(3) -- remote bridge is active not in standby } ACCESS read-only STATUS mandatory DESCRIPTION "This status says whether the remote bridge is active or in standby mode." ::= { s3EnetRemBridgeEntry 6 } -- Remote Bridge Port Table s3EnetRemBridgePortTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetRemBridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Port entries that are part of a remote bridge. The number of entries is determined by knowing the number of remote bridge boards that are installed by looking at s3ChassisSlotConfigTable and by knowing how many ports are on a remote bridge board by looking at s3EnetRemBridgePortCount." ::= { s3000EnetRemBridge 2 } s3EnetRemBridgePortEntry OBJECT-TYPE SYNTAX S3EnetRemBridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about the ports of the remote bridges that are currently plugged into the 3000 chassis." INDEX { s3EnetRemBridgePortSlotIndex, s3EnetRemBridgePortIndex } ::= { s3EnetRemBridgePortTable 1 } S3EnetRemBridgePortEntry ::= SEQUENCE { s3EnetRemBridgePortSlotIndex INTEGER, s3EnetRemBridgePortIndex INTEGER, s3EnetRemBridgePortMdaId INTEGER, s3EnetRemBridgePortDescr DisplayString, s3EnetRemBridgePortOpSts INTEGER, s3EnetRemBridgePortRdySnd INTEGER, s3EnetRemBridgePortClrSnd INTEGER, s3EnetRemBridgePortCarDt INTEGER } s3EnetRemBridgePortSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetRemBridgePortEntry 1 } s3EnetRemBridgePortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each port. Its value ranges between 1 and 12. The value for each port must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization." ::= { s3EnetRemBridgePortEntry 2 } s3EnetRemBridgePortMdaId OBJECT-TYPE SYNTAX INTEGER { other(1), ethernet(2), x21Barrier(3), x21Unbarrier(4), rs232(5), rs449(6), v35(7), g703(8), t1(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Medium dependent ID for the port." ::= { s3EnetRemBridgePortEntry 3 } s3EnetRemBridgePortDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the port." ::= { s3EnetRemBridgePortEntry 4 } s3EnetRemBridgePortOpSts OBJECT-TYPE SYNTAX INTEGER { other(1), standby(2), operational(3), noLink(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Operating status of the port." ::= { s3EnetRemBridgePortEntry 5 } s3EnetRemBridgePortRdySnd OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status rdySnd(2), -- ready to send notRdySnd(3) -- not ready to send } ACCESS read-only STATUS mandatory DESCRIPTION "Ready to send status of the port." ::= { s3EnetRemBridgePortEntry 6 } s3EnetRemBridgePortClrSnd OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status clrSnd(2), -- clear to send notClrSnd(3) -- not clear to send } ACCESS read-only STATUS mandatory DESCRIPTION "Clear to send status of the port." ::= { s3EnetRemBridgePortEntry 7 } s3EnetRemBridgePortCarDt OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown status carDt(2), -- carrier detected noCarDt(3) -- no carrier detected } ACCESS read-only STATUS mandatory DESCRIPTION "Carrier detect status of the port." ::= { s3EnetRemBridgePortEntry 8 } -- Router Board Table s3EnetRouterSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetRouterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Router Board entries. The number of entries is determined by the Concentrator Slot Configuration Table. Only those entries that are Ethernet routers will have entries in this list." ::= { s3000EnetRouter 1 } s3EnetRouterEntry OBJECT-TYPE SYNTAX S3EnetRouterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about Boards which are routers that are currently plugged into the 3000 chassis." INDEX { s3EnetRouterIndex } ::= { s3EnetRouterSlotTable 1 } S3EnetRouterEntry ::= SEQUENCE { s3EnetRouterIndex INTEGER, s3EnetRouterDescr DisplayString, s3EnetRouterDiagSts OCTET STRING, s3EnetRouterStandbySts INTEGER } s3EnetRouterIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { s3EnetRouterEntry 1 } s3EnetRouterDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Description of the router board." ::= { s3EnetRouterEntry 2 } s3EnetRouterDiagSts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Latest Diagnostic LED Status that has been recorded." ::= { s3EnetRouterEntry 3 } s3EnetRouterStandbySts OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown booting status standby(2), -- router is in standby mode notStandby(3) -- router is operational, not in standby } ACCESS read-only STATUS mandatory DESCRIPTION "This status says whether the router is active or in standby mode." ::= { s3EnetRouterEntry 4 } -- Port Table s3EnetPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of port entries. The number of entries is given by learning the type of board from the information in the s3ChassisSlotConfigTable." ::= { s3000EnetPort 1 } s3EnetPortEntry OBJECT-TYPE SYNTAX S3EnetPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing objects about the Ports of each board plugged into the 3000 chassis." INDEX { s3EnetPortBoardIndex, s3EnetPortIndex } ::= { s3EnetPortTable 1 } S3EnetPortEntry ::= SEQUENCE { s3EnetPortBoardIndex INTEGER, s3EnetPortIndex INTEGER, s3EnetPortLinkStatus INTEGER, s3EnetPortPartStatus INTEGER, s3EnetPortJabberStatus INTEGER, s3EnetPortFrmsRxOk Counter, s3EnetPortOctetsRxOk Counter, s3EnetPortMcastFrmsRxOk Counter, s3EnetPortBcastFrmsRxOk Counter, s3EnetPortColls Counter, s3EnetPortTooLongErrors Counter, s3EnetPortRuntErrors Counter, s3EnetPortAlignErrors Counter, s3EnetPortFcsErrors Counter, s3EnetPortLateCollErrors Counter, s3EnetPortMDIXSwitch INTEGER } s3EnetPortBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one reinitialization of the entity's network management system to the next reinitialization." ::= { s3EnetPortEntry 1 } s3EnetPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each port. Its value is dependent on the board type. The value for each port must remain constant at least from one reinitialization of the entity's network management system to the next reinitialization." ::= { s3EnetPortEntry 2 } s3EnetPortLinkStatus OBJECT-TYPE SYNTAX INTEGER { off(1), -- link is not connected on(2), -- link is connected other(3) -- returned for AUI } ACCESS read-only STATUS mandatory DESCRIPTION "Tells whether the port is receiving link status." ::= { s3EnetPortEntry 3 } s3EnetPortPartStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- port enabled partition(2), -- port partitioned autoPartition(3) -- port auto-partitioned } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates the operational status of the Port. Writing a partition(2) will partition the port indefinitely and enabled(1) will enable the port." ::= { s3EnetPortEntry 4 } s3EnetPortJabberStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), jabbering(2) -- Port receiving jabber } ACCESS read-only STATUS mandatory DESCRIPTION "Tells whether the DTE connected to the Port is jabbering or not." ::= { s3EnetPortEntry 5 } s3EnetPortFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the port. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes broadcast and multicast frames that are received." ::= { s3EnetPortEntry 6 } s3EnetPortOctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Contains a count of data and padding octets in frames that are successfully received by the port. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. This counter includes octets in broadcast and multicast frames that are received. This counter does not include the octets in the address, length/type and CRC fields." ::= { s3EnetPortEntry 7 } s3EnetPortMcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the port and are directed to an active non-broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Only frames that are for a multicast address that this interface is receiving are counted. Broadcast packets are not included." ::= { s3EnetPortEntry 8 } s3EnetPortBcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are successfully received by the port and are directed to the broadcast group address. This does not include frames received with a frame-too-long, runt, FCS, or alignment errors. Multicast packets are not included." ::= { s3EnetPortEntry 9 } s3EnetPortColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of the collision flags." ::= { s3EnetPortEntry 10 } -- Port MAC Error Statistics -- A hierarchical order has been established for those objects listed below -- such that when multiple error conditions can be associated with one frame, -- only one condition is counted. This hierarchy, in descending order is: -- frame too long -- runt frames -- alignment error -- frame check error s3EnetPortTooLongErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames that are received by the port and exceed the maximum permitted frame size. This counter is incremented when the frameTooLong error is detected." ::= { s3EnetPortEntry 11 } s3EnetPortRuntErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the port that are less than the minimum permitted frame size and have a good FCS." ::= { s3EnetPortEntry 12 } s3EnetPortAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received by the port that are not an integral number of octets in length and do not pass the FCS check. This counter is incremented when the alignmentError status is detected." ::= { s3EnetPortEntry 13 } s3EnetPortFcsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of frames received the port that are an integral number of octets in length that do not pass the FCS check. This counter is incremented when the frameCheckError status is detected." ::= { s3EnetPortEntry 14 } s3EnetPortLateCollErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This contains a count of the port level late collision flags." ::= { s3EnetPortEntry 15 } s3EnetPortMDIXSwitch OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown or other tenBaseT(2), -- 10BASE-T, "normal" or MDI-X tenBaseTMdi(3) -- 10BASE-T, switched to MDI } ACCESS read-only STATUS mandatory DESCRIPTION "This tells whether the MDI-X/MDI switch for the port is set to MDI-X or MDI position. If the port has an associated MDI-X/MDI switch, then the agent will return the current setting. If the port does not have the switch, then other(1) will be returned." ::= { s3EnetPortEntry 19 } -- SECTION 3: Network Management Module Group -- The Network Management Module Group consists of Module Group, -- EEPROM Configuration Group, Hardware Configuration Group, Trap -- Server Table, and Authentication Trap Control. -- -- All of these groups are DEPRECATED! -- Module Group s3EnetNmmType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following m3313(2), -- Model 3313 m3313M(3), -- Model 3313M m3314-ST(4), -- Model 3314-ST m3314M-ST(5), -- Model 3314M-ST m3138(6) -- Model 3138 } ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentType" ::= { s3000EnetNmm 1 } s3EnetNmmMdaHwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "See AgentMdaHwVer" ::= { s3000EnetNmm 2 } s3EnetNmmFwVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentFwVer" ::= { s3000EnetNmm 3 } s3EnetNmmSwMajorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentSwMajor" ::= { s3000EnetNmm 4 } s3EnetNmmSwMinorVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentSwMinor" ::= { s3000EnetNmm 5 } s3EnetNmmStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), -- the nmm is offline online(2) -- the nmm is online } ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentStatus" ::= { s3000EnetNmm 6 } s3EnetNmmMode OBJECT-TYPE SYNTAX INTEGER { primary(1), -- in primary mode secondary(2) -- in secondary mode } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentMode" ::= { s3000EnetNmm 7 } s3EnetNmmReset OBJECT-TYPE SYNTAX INTEGER { notreset(1), -- not reseting reset(2) -- reset } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentReset" ::= { s3000EnetNmm 8 } s3EnetNmmRestart OBJECT-TYPE SYNTAX INTEGER { notrestart(1), -- not restarting restart(2) -- restart } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentRestart" ::= { s3000EnetNmm 9 } -- EEPROM Configuration Group s3EnetNmmIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentIpAddr" ::= { s3000EnetNmm 10 } s3EnetNmmNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentNetMask" ::= { s3000EnetNmm 11 } s3EnetNmmDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentDefaultGateway" ::= { s3000EnetNmm 12 } s3EnetNmmFileServerAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentBootServerAddr" ::= { s3000EnetNmm 13 } s3EnetNmmBootFilePath OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentBootFile" ::= { s3000EnetNmm 14 } s3EnetNmmBootMode OBJECT-TYPE SYNTAX INTEGER { eeprom(1), -- get boot info from eeprom bootp(2) -- get boot info from bootp } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentBootMode" ::= { s3000EnetNmm 15 } s3EnetNmmWriteEeprom OBJECT-TYPE SYNTAX INTEGER { notWriteEeprom(1), -- not writing EEPROM writeEeprom(2) -- write EEPROM } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentWriteEeprom" ::= { s3000EnetNmm 16 } -- Hardware Configuration Group s3EnetNmmBaudRate OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS deprecated DESCRIPTION "See s3AgentBaudRate" ::= { s3000EnetNmm 17 } s3EnetNmmInitString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentInitString" ::= { s3000EnetNmm 18 } s3EnetNmmLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentLocation" ::= { s3000EnetNmm 19 } -- Trap Server Table s3EnetNmmTrapServerTable OBJECT-TYPE SYNTAX SEQUENCE OF S3EnetNmmTrapServerEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "See s3AgentReceiverTable" ::= { s3000EnetNmm 20 } s3EnetNmmTrapServerEntry OBJECT-TYPE SYNTAX S3EnetNmmTrapServerEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "See s3AgentTrapReceiverEntry" INDEX { s3EnetNmmTrapServerAddress } ::= { s3EnetNmmTrapServerTable 1 } S3EnetNmmTrapServerEntry ::= SEQUENCE { s3EnetNmmTrapType INTEGER, s3EnetNmmTrapServerAddress IpAddress, s3EnetNmmTrapServerComm OCTET STRING } s3EnetNmmTrapType OBJECT-TYPE SYNTAX INTEGER { other (1), -- none of the following invalid (2) -- an invalidated address } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentTrapRcvrStatus" ::= { s3EnetNmmTrapServerEntry 1 } s3EnetNmmTrapServerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentTrapRcvrNetAddress" ::= { s3EnetNmmTrapServerEntry 2 } s3EnetNmmTrapServerComm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentTrapRcvrComm" ::= { s3EnetNmmTrapServerEntry 3 } -- Authentication Trap Control s3EnetNmmAuthTrap OBJECT-TYPE SYNTAX INTEGER { disable(1), -- disable authentication traps enable(2) -- enable authentication traps } ACCESS read-write STATUS deprecated DESCRIPTION "See s3AgentAuthTrap" ::= { s3000EnetNmm 21 } END -- file: ieee802.3-1.0-09.30.91 SYNOPTICS-IEEE8023-MIB -- IEEE 802.3 MIB Release 1.0 -- DRAFT Revision 9/30/91 -- Printed 10/7/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS Counter FROM RFC1155-SMI PhysAddress FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 ieee8023 FROM SYNOPTICS-COMMON-MIB; -- SECTION 2: IEEE 802.3 Interface Statistics Table ieee8023IfTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8023IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Statistics for a list of interface entries. There is one entry per IEEE 802.3 like 'interface.'" ::= { ieee8023 1 } ieee8023IfEntry OBJECT-TYPE SYNTAX Ieee8023IfEntry ACCESS not-accessible STATUS mandatory INDEX { ieee8023IfIndex } ::= { ieee8023IfTable 1 } Ieee8023IfEntry ::= SEQUENCE { ieee8023IfIndex INTEGER, ieee8023FrmsTxOk Counter, ieee8023SingleCollFrms Counter, ieee8023MultipleCollFrms Counter, ieee8023OctetsTxOk Counter, ieee8023DefTx Counter, ieee8023McastFrmsTxOk Counter, ieee8023BcastFrmsTxOk Counter, ieee8023LateColls Counter, ieee8023ExcessColls Counter, ieee8023IntlMacTxError Counter, ieee8023CsErrors Counter, ieee8023ExcessDef Counter, ieee8023FrmsRxOk Counter, ieee8023OctetsRxOk Counter, ieee8023McastFrmsRxOk Counter, ieee8023BcastFrmsRxOk Counter, ieee8023TooLongErrors Counter, ieee8023AlignErrors Counter, ieee8023FcsErrors Counter, ieee8023IrLengthErrors Counter, ieee8023OorLengthFields Counter, ieee8023IntlMacRxErrors Counter, ieee8023InitMac INTEGER, ieee8023PromRxStatus INTEGER, ieee8023MacSubLayerStatus INTEGER, ieee8023TxStatus INTEGER, ieee8023McastRxStatus INTEGER, ieee8023MacAddress PhysAddress, ieee8023SqeTestErrors Counter } ieee8023IfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the interface. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ieee8023IfEntry 1 } ieee8023FrmsTxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are successfully transmitted. This counter is incremented when a frame is successfully transmitted, even if one of the collision counters (following two objects) is also counted. In other words, this count includes transmissions that succeeded after some number of collisions. This count includes multicast and broadcast frames." ::= { ieee8023IfEntry 2 } ieee8023SingleCollFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are involved in a single collision, and are subsequently transmitted successfully. If this counter is incremented, then the ieee8023FrmsTxOK count will also be incremented AND ieee8023MultipleCollFrms will NOT be incremented." ::= { ieee8023IfEntry 3 } ieee8023MultipleCollFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are involved in more than one collision and are subsequently transmitted successfully. If this counter is incremented, then the ieee8023FrmsTxOK count will also be incremented AND ieee8023SingleCollFrms will NOT be incremented." ::= { ieee8023IfEntry 4 } ieee8023OctetsTxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The amount of data AND PADDING octets of frames that are successfully transmitted. This counter includes octets in broadcast and multicast frames that are transmitted. This count does not include the address fields, length/type field, and CRC field of the frame. According to Ethernet terminology, it is purely the data field (IP header, etc.)." ::= { ieee8023IfEntry 5 } ieee8023DefTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames whose transmission was delayed on its first attempt because the medium was busy. Frames involved in collisions are NOT included in this count." ::= { ieee8023IfEntry 6 } ieee8023McastFrmsTxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames successfully transmitted to a multicast address. This counter does not include frames sent to the broadcast address." ::= { ieee8023IfEntry 7 } ieee8023BcastFrmsTxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames successfully transmitted to the broadcast address. This counter does not include frames sent to a multicast address." ::= { ieee8023IfEntry 8 } ieee8023LateColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that a collision has been detected later than 512 bit times into the transmission of a packet. 512 bit times is 51.2 micro secs. This type of collision is counted twice - both as a late collision and as a regular, ordinary collision." ::= { ieee8023IfEntry 9 } ieee8023ExcessColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are not transmitted because of excessive collisions." ::= { ieee8023IfEntry 10 } ieee8023IntlMacTxError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that would otherwise be transmitted by the station, but could not be sent because of an internal MAC sublayer transmit error. If this counter is incremented, then none of the other counters in this section are incremented. The exact meaning and mechanism for incrementing this counter is implementation dependent. In short, this is the count of errors for which there are no specific counters." ::= { ieee8023IfEntry 11 } ieee8023CsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that carrier sense was lost or never appeared when attempting to transmit a packet. This counter is incremented ONCE per transmission attempt, even if Carrier Sense fluctuates." ::= { ieee8023IfEntry 12 } ieee8023ExcessDef OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that deferred for an excessive period of time." ::= { ieee8023IfEntry 13 } ieee8023FrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are successfully received. This counter does not include frames received with frame-too-long, FCS, length, or alignment errors, or frames lost because of internal MAC sublayer error. This counter includes broadcast and multicast frames that are received." ::= { ieee8023IfEntry 14 } ieee8023OctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number entry of data and padding octets in frames that are successfully received. This counter does not include frames received with frame-too-long, FCS, length, or alignment errors, or frames lost because of internal MAC sublayer error. This counter includes octets in broadcast and multicast frames that are received. This counter does not include the octets in the address, length/type, and CRC fields." ::= { ieee8023IfEntry 15 } ieee8023McastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are successfully received and are directed to an active non-broadcast group address. This counter does not include frames received with frame-too-long, FCS, length, or alignment errors, or frames lost because of internal MAC sublayer error. Only frames for a multicast address that this interface is receiving are counted. Broadcast packets are not included." ::= { ieee8023IfEntry 16 } ieee8023BcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are successfully received and are directed to the broadcast group address. This counter does not include frames received with frame-too-long, FCS, length, or alignment errors, or frames lost because of internal MAC sublayer error. Multicast packets are not included." ::= { ieee8023IfEntry 17 } ieee8023TooLongErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are received and exceed the maximum permitted frame size. This counter is incremented when the frameTooLong error is returned." ::= { ieee8023IfEntry 18 } ieee8023AlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are not an integral number of octets in length and do not pass the FCS check. This counter is incremented when the alignmentError status is returned to the LLC." ::= { ieee8023IfEntry 19 } ieee8023FcsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that are an integral number of octets in length and do not pass the FCS check. This counter is incremented when the frameCheckError status is returned to the LLC." ::= { ieee8023IfEntry 20 } ieee8023IrLengthErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames with a length field value between the minimum unpadded LLC data size and the maximum allowed LLC data size inclusive, and which do not match the number of LLC data octets received. The counter also contains frames with a length field value less than the minimum unpadded LLC data size." ::= { ieee8023IfEntry 21 } ieee8023OorLengthFields OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames with a length field value greater than the maximum allowed LLC data size. If true 802.3 is followed for layer management, then this counter will be incremented for every IP or ARP frame received that uses the Ethernet encapsulation method. Both IP and ARP use type field values that will cause this counter to be incremented, showing a high error rate." ::= { ieee8023IfEntry 22 } ieee8023IntlMacRxErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that would otherwise be received by the station, but could not be accepted because of an internal MAC sublayer receive error. If this counter is incremented, then none of the other counters in this section are incremented. The exact meaning and mechanism for incrementing this counter is implementation dependent. This is the count of other errors." ::= { ieee8023IfEntry 23 } ieee8023InitMac OBJECT-TYPE SYNTAX INTEGER { initialize(1), uninitialize(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Reinitializes the MAC and PLS (physical layer signaling). All MIB counters are set to 0. The states of the status variables (described below) are as follows: - The receive and transmit Layer Management state variables (receiveEnabled and transmitEnabled) are set to enable reception and transmission of frames. - The promiscuous receive function is disabled. - Multicast reception is disabled." ::= { ieee8023IfEntry 24 } ieee8023PromRxStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable combines the enable ieee8023PromRx, disable ieee8023PromRx, and read ieee8023PromStatus MAC actions. Setting this variable to enabled causes the interface to accept frames regardless of their destination address. When enabled, all received frames increment all counters as though those frames were directed to this station. Frames can be promiscuously received only if the ieee8023MacSubLayerStatus variable is also set to enabled(1)." ::= { ieee8023IfEntry 25 } ieee8023MacSubLayerStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable causes the MAC sublayer to enter the normal operational state at idle. The PLS is reset by this operation. It is accomplished by setting receiveEnabled and transmitEnabled to true. Setting this variable to enabled(1) enables the MAC sublayer to both receive and transmit frames. Setting this variable to enabled(1) will also set the ieee8023TransmitStatus variable to enabled(1). Similarly, setting this variable to disabled(2) will also set ieee8023TransmitStatus to disabled(2). Modifying this variable does not change the state of any other variables. If the variable is set to disabled(2), then any current transmission/reception is completed before the transmission/reception process is disabled. The value returned when this variable is read is the logical and of the receiveEnabled and transmitEnabled MAC internal state variables. If both are in the enabled state, then enabled(1) is returned; otherwise disabled(2) is returned." ::= { ieee8023IfEntry 26 } ieee8023TxStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable enables the MAC sublayer to be explicitly enabled/disabled for transmitting frames. If a frame is being transmitted when this variable is set to disabled(2), that transmission is completed. Note that ieee8023MACSubLayerStatus has an effect on this variable." ::= { ieee8023IfEntry 27 } ieee8023McastRxStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/disables reception of multicast frames. To actually receive multicasts, both this variable AND ieee8023MacSubLayerStatus must be set to enabled." ::= { ieee8023IfEntry 28 } ieee8023MacAddress OBJECT-TYPE SYNTAX PhysAddress (SIZE (6)) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the MAC station address (i.e., the Ethernet address)." ::= { ieee8023IfEntry 29 } ieee8023SqeTestErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the SQE TEST ERROR status was received." ::= { ieee8023IfEntry 30 } -- SECTION 3: Collision Frames Table ieee8023CollTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8023CollEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information on collision activity." ::= { ieee8023 2 } ieee8023CollEntry OBJECT-TYPE SYNTAX Ieee8023CollEntry ACCESS not-accessible STATUS mandatory INDEX { ieee8023CollRetrans, ieee8023CollIndex } ::= { ieee8023CollTable 1 } Ieee8023CollEntry ::= SEQUENCE { ieee8023CollRetrans INTEGER, ieee8023CollIndex INTEGER, ieee8023Collisions Counter } ieee8023CollRetrans OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The entry corresponding to the number of attempts made before a frame was successfully transmitted. The range is from 1 to 15." ::= { ieee8023CollEntry 1 } ieee8023CollIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index value that uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ieee8023CollEntry 2 } ieee8023Collisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that were retransmitted a specific number of times." ::= { ieee8023CollEntry 3 } -- SECTION 4: Multicast Address Table ieee8023GroupTable OBJECT-TYPE SYNTAX SEQUENCE OF Ieee8023GroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information on group addresses. There are five entries in the table." ::= { ieee8023 3 } ieee8023GroupEntry OBJECT-TYPE SYNTAX Ieee8023GroupEntry ACCESS not-accessible STATUS mandatory INDEX { ieee8023GroupIndex, ieee8023GroupAddress } ::= { ieee8023GroupTable 1 } Ieee8023GroupEntry ::= SEQUENCE { ieee8023GroupIndex INTEGER, ieee8023GroupAddress PhysAddress, ieee8023GroupType INTEGER } ieee8023GroupIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index value that uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { ieee8023GroupEntry 1 } ieee8023GroupAddress OBJECT-TYPE SYNTAX PhysAddress (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "A group address to which this Ethernet-like interface responds." ::= { ieee8023GroupEntry 2 } ieee8023GroupType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following invalid(2) -- an invalidated group } ACCESS read-write STATUS mandatory DESCRIPTION "Type of group address. Setting this object to the value invalid(2) invalidates the corresponding entry in the ieee8023GroupTable. That is, it effectively disassociates the interface identified with said entry from the group address identified with said entry. Whether the agent removes an invalidated entry from the table is an implementation-specific matter. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ieee8023GroupType object." ::= { ieee8023GroupEntry 3 } END -- file: tr3.1-10.25.91 SYNOPTICS-TOKENRING-MIB -- Token Ring MIB 3.1 -- DRAFT Revision 10/25/91 -- Printed 10/29/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 s3000TokenRing FROM SYNOPTICS-COMMON-MIB; -- Groups s3000TrBoard OBJECT IDENTIFIER ::= { s3000TokenRing 2 } s3000TrPort OBJECT IDENTIFIER ::= { s3000TokenRing 3 } s3000TrNmm OBJECT IDENTIFIER ::= { s3000TokenRing 4 } s3000TrNode OBJECT IDENTIFIER ::= { s3000TokenRing 5 } s3000TrRing OBJECT IDENTIFIER ::= { s3000TokenRing 7 } s3TrRingStats OBJECT IDENTIFIER ::= { s3000TrRing 1 } -- SECTION 2: Token Ring Board Group -- Common Board Table s3TrCommonBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrCommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information maintained for each token ring board. The information can be retrieved for any token ring board, even if the board is not on the same backplane ring as this NMM. The instance is the slot number of the concentrator that the board occupies." ::= { s3000TrBoard 2 } s3TrCommonBoardEntry OBJECT-TYPE SYNTAX S3TrCommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one entry per board in this table." INDEX { s3TrCommonBoardIndex } ::= { s3TrCommonBoardTable 1 } S3TrCommonBoardEntry ::= SEQUENCE { s3TrCommonBoardIndex INTEGER, s3TrCommonBoardRing1or2 INTEGER, s3TrCommonBoardRingSpeed INTEGER } s3TrCommonBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If a board is inserted or reinserted in a concentrator then the NMM has to be reinitialized." ::= { s3TrCommonBoardEntry 1 } s3TrCommonBoardRing1or2 OBJECT-TYPE SYNTAX INTEGER { other(1), -- not a valid ring number ring1(2), -- use/using ring 1 on the concentrator ring2(3) -- use/using ring 2 on the concentrator } ACCESS read-only STATUS mandatory DESCRIPTION "Determines which ring the board is currently using on the concentrator backplane." ::= { s3TrCommonBoardEntry 2 } s3TrCommonBoardRingSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown speed speed1M(2), -- 1 Mbps for standard compatibility speed4M(3), -- 4 Mbps speed16M(4) -- 16 Mbps } ACCESS read-only STATUS mandatory DESCRIPTION "Token Ring speed of the ring that this board is connected to." ::= { s3TrCommonBoardEntry 3 } -- SECTION 3: Token Ring Port Group -- Port Table s3TrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each port of a LattisNet concentrator. The number of entries is given by knowing the number of occupied slots in s3ChassisSlotConfigTable whose s3SlotModuleType is of a token ring type and is on the same physical ring as the agent NMM." ::= { s3000TrPort 1 } s3TrPortEntry OBJECT-TYPE SYNTAX S3TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port entry containing objects at the port level for a particular port." INDEX { s3TrPortBoardIndex, s3TrPortIndex } ::= { s3TrPortTable 1 } S3TrPortEntry ::= SEQUENCE { s3TrPortBoardIndex INTEGER, s3TrPortIndex INTEGER, s3TrPortWrap INTEGER, s3TrPortTestLatch INTEGER, s3TrPortRelayStatus INTEGER, s3TrPortPhantomStatus INTEGER, s3TrPortPhantomChangeFlag INTEGER, s3TrPortChgSyn2IBM INTEGER, s3TrPortStrap INTEGER } s3TrPortBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If a board is inserted or reinserted in a concentrator then the NMM has to be reinitialized." ::= { s3TrPortEntry 1 } s3TrPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each port. Its value ranges between 1 and 12. The value for each port must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If the board is an NMM board it will only have 2 ports, with Port 1 being for Ring In and Port 2 being for Ring Out." ::= { s3TrPortEntry 2 } s3TrPortWrap OBJECT-TYPE SYNTAX INTEGER { other(1), -- port not wrapped or connected wrap(2), connect(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Status of the port. Setting wrap(2) disconnects the port from the ring and setting this object to connect(3) connects the port to the ring." ::= { s3TrPortEntry 3 } s3TrPortTestLatch OBJECT-TYPE SYNTAX INTEGER { other(1), -- not supported on(2), -- test latch activated off(3) -- test latch not activated } ACCESS read-write STATUS mandatory DESCRIPTION "Status of the test latch which is used to set the channel decoder used to monitor the health of the communication path between the NMM and the module channel." ::= { s3TrPortEntry 4 } s3TrPortRelayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- not supported on(2), -- channel is part of the ring off(3) -- channel is bypassed } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the channel's present relay mode. On(2) means the channel is in the ring and off(3) means the channel is bypassed." ::= { s3TrPortEntry 5 } s3TrPortPhantomStatus OBJECT-TYPE SYNTAX INTEGER { other(1), on(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the ring access request signal." ::= { s3TrPortEntry 6 } s3TrPortPhantomChangeFlag OBJECT-TYPE SYNTAX INTEGER { other(1), noChange(2), change(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Change(3) indicates that port phantom has been changed from OFF to ON. After inquiry by NMS, it will be cleared to noChange(2). Port phantom changing from ON to OFF has no impact on this object." ::= { s3TrPortEntry 7 } s3TrPortChgSyn2IBM OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), ibm(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If the port is on a ring in/ring out module this object changes the strap state depending on the jumper setting retrieved as s3TrPortStrap. If the strap is set for SynOptics phantom option, this object can be changed to ibm(3). If the strap is set for non-SynOptics option, this object can not be changed. Non ring in/ring out modules or fiber ring in/ring out modules must take on the value of notSupported(1)." ::= { s3TrPortEntry 8 } s3TrPortStrap OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), ibm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "If the port is on a ring in/ring out module this object signifies whether the hardware jumper is in synoptics(2) mode or ibm(3) mode. This information is retrieved using a NMI command. For ports on fiber ring in/ring out modules, and those ports not on ring in/ring out modules, the agent always returns notSupported(1)." ::= { s3TrPortEntry 9 } -- SECTION 4: Token Ring NMM Group s3TrNmmFnNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the flat network number that this NMM is part of." ::= { s3000TrNmm 1 } s3TrNmmRingNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the segment number that this NMM is connected to." ::= { s3000TrNmm 2 } s3TrNmmSlotNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Defines the slot number that this NMM is connected to. New NMS implementations should use the object s3AgentMySlotId defined in the common MIB." ::= { s3000TrNmm 3 } s3TrNmmFpuIdRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the Front-end Frame Processing unit. 0=Rev. A, 1=Rev. B, etc." ::= { s3000TrNmm 4 } s3TrNmmFpuStatus OBJECT-TYPE SYNTAX INTEGER { notPresent(1), notOperational(2), -- present, but not operational operational(3) -- present and operational } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Front-end Frame Processing Unit." ::= { s3000TrNmm 5 } s3TrNmmDramSize OBJECT-TYPE SYNTAX INTEGER{ other(1), -- unknown size k512(2), -- 512K memory oneMeg(3), twoMeg(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The highest address of the DRAM in the NMM memory map." ::= { s3000TrNmm 6 } s3TrNmmEepromSize OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown size k2kby8(2), -- 2k*8 k8kby8(3) -- 8k*8 } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the EEPROM in the NMM memory map." ::= { s3000TrNmm 7 } s3TrNmmGrpAddrFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Group Address frames received without error by this NMM. Note: The NMM counts only Group Address frames that are addressed to its own Group Address(es)." ::= { s3000TrNmm 8 } s3TrNmmRing1or2 OBJECT-TYPE SYNTAX INTEGER { other(1), -- not a valid ring number ring1(2), -- use/using ring 1 on the concentrator ring2(3) -- use/using ring 2 on the concentrator } ACCESS read-only STATUS mandatory DESCRIPTION "Determines which ring the NMM is currently using on the concentrator backplane." ::= { s3000TrNmm 9 } s3TrNmmRingSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown speed speed1M(2), -- 1 Mbps for standard compatibility speed4M(3), -- 4 Mbps speed16M(4) -- 16 Mbps } ACCESS read-only STATUS mandatory DESCRIPTION "Token Ring speed." ::= { s3000TrNmm 10 } s3TrNmmHexDisplay OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "4 octet hex display string that is displayed on the NMM control panel." ::= { s3000TrNmm 11 } s3TrNmmEpromSize OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown size k2kby8(2), -- 2k*8 k8kby8(3), -- 8k*8 k16kby8(4), -- 16k*8 k32kby8(5), -- 32k*8 k64kby8(6), -- 64k*8 k128kby8(7), -- 128k*8 k256kby8(8) -- 256k*8 } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the EPROM in the NMM memory map." ::= { s3000TrNmm 12 } -- SECTION 5: Token Ring Station Group -- Node table -- list of all nodes that are active on the local token ring that this -- concentrator is connected to. s3TrNodeTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing station specific information." ::= { s3000TrNode 1 } s3TrNodeEntry OBJECT-TYPE SYNTAX S3TrNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the table containing counters and profiling information for each node detected on the local token ring." INDEX { s3TrNodeEntMacAddress } ::= { s3TrNodeTable 1 } S3TrNodeEntry ::= SEQUENCE { s3TrNodeEntMacAddress OCTET STRING, s3TrNodeEntStatus INTEGER, s3TrNodeEntNodeStatus OCTET STRING, s3TrNodeLineErrs Counter, s3TrNodeBurstErrs Counter, s3TrNodeAriFciErrs Counter, s3TrNodeLostFrames Counter, s3TrNodeRcvCongestErrs Counter, s3TrNodeFrmCopyErrs Counter, s3TrNodeTokenErrs Counter, s3TrNodeInternalErrs Counter, s3TrNodeAbortTransErrs Counter, s3TrNodeFrequencyErrs Counter, s3TrNodeEntProductId OCTET STRING, s3TrNodeEntUna OCTET STRING, s3TrNodeEntNodeVersion OCTET STRING, s3TrNodeEntPhysDrop OCTET STRING, s3TrNodeEntFuncAddr OCTET STRING, s3TrNodeEntAuthFuncClass OCTET STRING, s3TrNodeEntAuthAccPriority OCTET STRING, s3TrNodeEntGrpAddr OCTET STRING, s3TrNodeEntStationId OCTET STRING, s3TrNodeEntBeaconType INTEGER, s3TrNodeBeaconCnt Counter, s3TrNodeLastBeaconTime TimeTicks, s3TrNodeLastInsertTime TimeTicks, s3TrNodeFirstInsertTime TimeTicks, s3TrNodeLastDeinsertTime TimeTicks, s3TrNodeRemoveStation INTEGER } s3TrNodeEntMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "MAC address of node that this entry in the table is for." ::= { s3TrNodeEntry 1 } s3TrNodeEntStatus OBJECT-TYPE SYNTAX INTEGER { beaconing(1), notBeaconing(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Tells whether the station is currently beaconing or not." ::= { s3TrNodeEntry 4 } s3TrNodeEntNodeStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Node status as defined in 802.5 specification (section 3.3.2.18)." ::= { s3TrNodeEntry 5 } s3TrNodeLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of line errors. Section 3.8.1 of IEEE 802.5 specification." ::= { s3TrNodeEntry 6 } s3TrNodeBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of burst errors. Section 3.8.3 of IEEE 802.5 specification." ::= { s3TrNodeEntry 7 } s3TrNodeAriFciErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of ARI FCI errors. See AC errors, Section 3.8.4 of IEEE 802.5 specification." ::= { s3TrNodeEntry 8 } s3TrNodeLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames lost. Section 3.8.6 of IEEE 802.5 specification." ::= { s3TrNodeEntry 9 } s3TrNodeRcvCongestErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive congestion errors. Section 3.8.7 of IEEE 802.5 specification." ::= { s3TrNodeEntry 10 } s3TrNodeFrmCopyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frame copy errors. Section 3.8.8 of IEEE 802.5 specification." ::= { s3TrNodeEntry 11 } s3TrNodeTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of token errors. Section 3.8.10 of IEEE 802.5 specification." ::= { s3TrNodeEntry 12 } s3TrNodeInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of internal errors. Section 3.8.2 of IEEE 802.5 specification." ::= { s3TrNodeEntry 13 } s3TrNodeAbortTransErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of abort delimiter transmitted errors. Section 3.8.5 of IEEE 802.5 specification." ::= { s3TrNodeEntry 14 } s3TrNodeFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frequency errors. Section 3.8.9 of IEEE 802.5 specification." ::= { s3TrNodeEntry 15 } s3TrNodeEntProductId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(18)) ACCESS read-only STATUS mandatory DESCRIPTION "A brief string describing the product specified by the vendor. Section 3.3.2.14 of IEEE 802.5 specification. The characters in the string are represented in EBCDIC for IBM products, in ASCII for others." ::= { s3TrNodeEntry 16 } s3TrNodeEntUna OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The Upstream Neighbor Address. Section 3.3.2.15 of IEEE 802.5 specification." ::= { s3TrNodeEntry 17 } s3TrNodeEntNodeVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) ACCESS read-only STATUS mandatory DESCRIPTION "String that represents the version of the station software. Section 3.3.2.17 of IEEE 802.5 specification. The characters in the string are represented in EBCDIC for IBM products, in ASCII for others." ::= { s3TrNodeEntry 18 } s3TrNodeEntPhysDrop OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This reports the physical location of this node on the ring. Section 3.3.2.13 of IEEE 802.5 specification." ::= { s3TrNodeEntry 19 } s3TrNodeEntFuncAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the functional addresses used by this station. Section 3.3.2.8 of IEEE 802.5 specification." ::= { s3TrNodeEntry 20 } s3TrNodeEntAuthFuncClass OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the functional classes that are allowed to be active in the station. Section 3.3.2.3 of IEEE 802.5 specification." ::= { s3TrNodeEntry 21 } s3TrNodeEntAuthAccPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum priority this station is allowed to use. Section 3.3.2.2 of IEEE 802.5 specification." ::= { s3TrNodeEntry 22 } s3TrNodeEntGrpAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This contains the group address of this station. Section 3.3.2.9 of IEEE 802.5 specification." ::= { s3TrNodeEntry 23 } s3TrNodeEntStationId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This string is used to uniquely identify the station. It may be equal to the station's MAC address. Section 3.3.2.21 of IEEE 802.5 specification." ::= { s3TrNodeEntry 24 } s3TrNodeEntBeaconType OBJECT-TYPE SYNTAX INTEGER { reconfiguration(1), signal-loss(2), bit-streaming(3), contention-streaming(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of beacon frame seen. Section 3.3.2.4 of IEEE 802.5 specification." ::= { s3TrNodeEntry 25 } s3TrNodeBeaconCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of beacon frames that have been sent by this station." ::= { s3TrNodeEntry 26 } s3TrNodeLastBeaconTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last beacon frame sent by this station." ::= { s3TrNodeEntry 27 } s3TrNodeLastInsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last ring insertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 28 } s3TrNodeFirstInsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the first ring insertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 29 } s3TrNodeLastDeinsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last ring deinsertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 30 } s3TrNodeRemoveStation OBJECT-TYPE SYNTAX INTEGER { other(1), -- do nothing remove(2) -- remove the MAC address } ACCESS read-write STATUS mandatory DESCRIPTION "Removes the MAC address associated with this entry from the ring by sending a REMOVE MAC frame if this object is written to with remove(2)." ::= { s3TrNodeEntry 31 } -- SECTION 6: Token Ring "RING" Group s3TrRingStatus OBJECT-TYPE SYNTAX INTEGER { beaconing(1), notbeaconing(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the ring." ::= { s3TrRingStats 1 } s3TrRingFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received successfully by the NMM." ::= { s3TrRingStats 2 } s3TrRingOctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of octets received successfully by the NMM." ::= { s3TrRingStats 3 } s3TrRingBcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of broadcast frames received successfully by the NMM." ::= { s3TrRingStats 4 } s3TrRingLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of line errors. Section 3.8.1 of IEEE 802.5 specification." ::= { s3TrRingStats 5 } s3TrRingBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of burst errors. Section 3.8.3 of IEEE 802.5 specification." ::= { s3TrRingStats 6 } s3TrRingAriFciErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of ARI FCI errors. See AC errors, Section 3.8.4 of IEEE 802.5 specification." ::= { s3TrRingStats 7 } s3TrRingLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames lost. Section 3.8.6 of IEEE 802.5 specification." ::= { s3TrRingStats 8 } s3TrRingRcvCongestErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive congestion errors. Section 3.8.7 of IEEE 802.5 specification." ::= { s3TrRingStats 9 } s3TrRingFrmCopyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frame copy errors. Section 3.8.8 of IEEE 802.5 specification." ::= { s3TrRingStats 10 } s3TrRingTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of token errors. Section 3.8.10 of IEEE 802.5 specification." ::= { s3TrRingStats 11 } s3TrRingInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of internal errors. Section 3.8.2 of IEEE 802.5 specification." ::= { s3TrRingStats 12 } s3TrRingAbortTransErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of abort delimiter transmitted errors. Section 3.8.5 of IEEE 802.5 specification." ::= { s3TrRingStats 13 } s3TrRingFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frequency errors. Section 3.8.9 of IEEE 802.5 specification." ::= { s3TrRingStats 14 } s3TrRingBeaconCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of beacon frames that have been seen." ::= { s3TrRingStats 15 } s3TrRingBeaconType OBJECT-TYPE SYNTAX INTEGER { reconfiguration(1), signal-loss(2), bit-streaming(3), contention-streaming(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of beacon frame seen. Section 3.3.2.4 of IEEE 802.5 Specification." ::= { s3TrRingStats 16 } s3TrRingLastBeaconTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last beacon frame sent on the ring. Time is relative from the system uptime." ::= { s3TrRingStats 17 } s3TrRingBeaconStation OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of station last beaconing." ::= { s3TrRingStats 18 } END -- file: traps1.0-09.30.91 SYNOPTICS-TRAP-MIB -- Trap MIB Release 1.0 -- Revision 9/30/91 -- Printed 9/30/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS snmp, ifIndex, egpNeighAddr FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 synoptics, s3ChassisPsStatus, s3ChassisFanStatus, s3CommonBoardPsStatus FROM SYNOPTICS-COMMON-MIB s3EnetBoardStatus, s3EnetBoardPsStatus, s3EnetPortPartStatus, s3EnetPortJabberStatus, s3EnetLocBridgePortOpSts, s3EnetLocBridgeDiagSts, s3EnetRemBridgePortOpSts, s3EnetRemBridgeDiagSts, s3EnetRouterStandbySts, s3EnetRouterDiagSts FROM SYNOPTICS-ETHERNET-MIB ieee8023PromRxStatus FROM SYNOPTICS-IEEE8023-MIB s3TrNmmRingNum, s3TrNodeEntUna, s3TrNodeEntBeaconType, s3TrNodeEntPhysDrop FROM SYNOPTICS-TOKENRING-MIB; -- SECTION 2: Generic Trap Definitions coldStart TRAP-TYPE ENTERPRISE snmp -- STATUS mandatory for all SynOptics agents DESCRIPTION "A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered." ::= 0 warmStart TRAP-TYPE ENTERPRISE snmp -- STATUS implemented by TR 3.1 only, not supported in future DESCRIPTION "A warmStart trap signifies that the sending protocol entity is reinitializing itself such that neither the agent configuration nor the protocol entity implementation is altered." ::= 1 linkDown TRAP-TYPE ENTERPRISE snmp VARIABLES { ifIndex } -- STATUS not used by TR or Enet DESCRIPTION "A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration." ::= 2 linkUp TRAP-TYPE ENTERPRISE snmp VARIABLES { ifIndex } -- STATUS not used by TR or Enet DESCRIPTION "A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up." ::= 3 authenticationFailure TRAP-TYPE ENTERPRISE snmp -- STATUS mandatory for all SynOptics agents DESCRIPTION "An authenticationFailure trap signifies that the sending protocol entity is the addressee of a protocol message that is not properly authenticated. While implementations of the SNMP must be capable of generating this trap, they must also be capable of suppressing the emission of such traps via an implementation-specific mechanism." ::= 4 egpNeighborLoss TRAP-TYPE ENTERPRISE snmp VARIABLES { egpNeighAddr } -- STATUS mandatory if EGP implemented (routers only) DESCRIPTION "An egpNeighborLoss trap signifies that an EGP neighbor for whom the sending protocol entity was an EGP peer has been marked down and the peer relationship no longer obtains." ::= 5 -- SECTION 3: SynOptics Enterprise Trap Definitions chassisPowerSupplyFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3ChassisPsStatus } -- STATUS mandatory for all SynOptics agents DESCRIPTION "Concentrator power supply failure." ::= 0 -- 0x00 chassisFanFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3ChassisFanStatus } -- STATUS mandatory for all SynOptics agents DESCRIPTION "Concentrator fan failure." ::= 1 -- 0x01 boardFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetBoardStatus } -- STATUS mandatory for 3.x Ethernet agents. DESCRIPTION "General board failure detected by Ethernet NMM." ::= 2 -- 0x02 enetBoardPowerSupplyFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetBoardPsStatus } -- STATUS mandatory for 3.x Ethernet agents. -- Token ring agents use -- boardPowerSupplyFailure (27) instead. DESCRIPTION "Ethernet board power supply failure." ::= 3 -- 0x03 portAutoPartition TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetPortPartStatus, s3EnetPortJabberStatus } -- STATUS mandatory for all Ethernet agents DESCRIPTION "Port auto partitions." ::= 4 -- 0x04 portDTEJabbering TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetPortJabberStatus } -- STATUS mandatory for all Ethernet agents DESCRIPTION "Ethernet DTE jabbering detected." ::= 5 -- 0x05 nmmSaturation TRAP-TYPE ENTERPRISE synoptics VARIABLES { ieee8023PromRxStatus } -- STATUS mandatory for 3.x Ethernet agents DESCRIPTION "NMM is dropping packets due to overload." ::= 6 -- 0x06 localBridgePortOperationChanged TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetLocBridgePortOpSts } -- STATUS mandatory for 3.x Ethernet agents DESCRIPTION "Bridge changes from standby <-> operation." ::= 7 -- 0x07 localBridgeDiagnostic TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetLocBridgeDiagSts } -- STATUS mandatory for 3.x Ethernet agents DESCRIPTION "NMM detects bridge failure." ::= 8 -- 0x08 remoteBridgePortOperationChanged TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetRemBridgePortOpSts } -- STATUS mandatory for 3.x Ethernet agents DESCRIPTION "Bridge changes from standby <-> operation." ::= 9 -- 0x09 remoteBridgeDiagnostic TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetRemBridgeDiagSts } -- STATUS mandatory for 3.x Ethernet agents DESCRIPTION "NMM detects remote bridge failure." ::= 10 -- 0x0a stationBeacons TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3TrNmmRingNum, s3TrNodeEntUna, s3TrNodeEntBeaconType } -- STATUS mandatory for all Token Ring agents DESCRIPTION "Station on the ring is beaconing." ::= 14 -- 0x0e newActMonDetect TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3TrNmmRingNum, s3TrNodeEntUna, s3TrNodeEntPhysDrop } -- STATUS mandatory for all Token Ring agents DESCRIPTION "A new active monitor has been detected." ::= 22 -- 0x16 boardPowerSupplyFailure TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3CommonBoardPsStatus } -- STATUS mandatory for all Token Ring agents DESCRIPTION "Board power supply failure." ::= 27 -- 0x1b routerOperationChanged TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetRouterStandbySts } -- STATUS mandatory for 3.3 Ethernet agents DESCRIPTION "Router changes from standby <-> operation." ::= 33 -- 0x21 routerDiagnostic TRAP-TYPE ENTERPRISE synoptics VARIABLES { s3EnetRouterDiagSts } -- STATUS mandatory for 3.3 Ethernet agents DESCRIPTION "NMM detects router failure." ::= 34 -- 0x22 END