BayNetworks-BPKG-MIB device MIB details by Wellfleet
BayNetworks-BPKG-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing BayNetworks-BPKG-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | BayNetworks-BPKG-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
--BPKG mib file for BAC PktGen --Created 4/22/98 cying Initial version. BayNetworks-BPKG-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB wfBacPktGenGroup FROM Wellfleet-COMMON-MIB; wfBacPktGenBase OBJECT IDENTIFIER ::= { wfBacPktGenGroup 1 } wfBacPktGenDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete BAC PktGen." DEFVAL { created } ::= { wfBacPktGenBase 1 } wfBacPktGenDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. Default is disabled. Users perform a set operation on this object in order to enable/disable BAC PktGen." DEFVAL { disabled } ::= { wfBacPktGenBase 2 } wfBacPktGenState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the entire BAC PktGen: up - BAC PktGen is sending and receiving frames; down - BAC PktGen is disabled; init - BAC PktGen is initializing; notpresent - BAC PktGen is not present. " DEFVAL { notpresent } ::= { wfBacPktGenBase 3 } wfBacPktGenTxTabSum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of TXTAB records added to CXP's." ::= { wfBacPktGenBase 4 } wfBacPktGenRxTabSum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of RXTAB records added to CXP's." ::= { wfBacPktGenBase 5 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenBase -- ---------------------------------------------------------------------- wfBacPktGenCxpTable OBJECT-TYPE SYNTAX SEQUENCE OF WfBacPktGenCxpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The BAC PktGen CXP table contains relevant information concerning packet generation on each CXP. Note that, the processing of PktGen CXP entries supercedes that of wfBacPktGenCxpGlobal MIB record." ::= { wfBacPktGenGroup 2 } wfBacPktGenCxpEntry OBJECT-TYPE SYNTAX WfBacPktGenCxpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information concerning packet generation on the CXP." INDEX { wfBacPktGenCxpId } ::= { wfBacPktGenCxpTable 1 } WfBacPktGenCxpEntry ::= SEQUENCE { wfBacPktGenCxpDelete INTEGER, wfBacPktGenCxpId INTEGER, wfBacPktGenStreamMask Counter } wfBacPktGenCxpDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete BAC PktGen CXP table entry." DEFVAL { created } ::= { wfBacPktGenCxpEntry 1 } wfBacPktGenCxpId OBJECT-TYPE SYNTAX INTEGER(6..8) ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies the CXP from which test packets are generated. Currently, the CXP is identified by its slot number, which must be between 6 and 8." ::= { wfBacPktGenCxpEntry 2 } wfBacPktGenStreamMask OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "Bit mask for generating test packets on the CXP streams 1-31. The least significant bit is ignored. The second least significant bit represents stream 1, the next least significant bit represents stream 2, and so forth. The most significant bit represents stream 31." ::= { wfBacPktGenCxpEntry 3 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenCxpEntry -- ---------------------------------------------------------------------- wfBacPktGenPktSeed OBJECT IDENTIFIER ::= { wfBacPktGenGroup 3 } wfBacPktGenSeedPkts OBJECT-TYPE SYNTAX INTEGER { seedpackets(1), unseedpackets(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Seed/Unseed packet parameter. Default is unseedpackets. Users perform a set operation on this object in order to seed/unseed test packets." DEFVAL { unseedpackets } ::= { wfBacPktGenPktSeed 1 } wfBacPktGenPktSeedState OBJECT-TYPE SYNTAX INTEGER { packetseeded(1), packetunseeded(2), operationstarted(3), idle(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Based on the set operation performed on the Seed/Unseed packet parameter, this object reflects the status of the operation. Default is idle. This object goes to the operationstarted state as soon as the BAC PktGen application detects the set operation on the Seed/Unseed parameter. The object remains in this state until the operation is completed, and the appropriate state is registered." DEFVAL { idle } ::= { wfBacPktGenPktSeed 2 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenPktSeed -- ---------------------------------------------------------------------- wfBacPktGenCxpGlobal OBJECT IDENTIFIER ::= { wfBacPktGenGroup 4 } wfBacPktGenCxpGlobalDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete BAC PktGen CXP Global record. Note that, the PktGen Global record is processed as long as no wfBacPktGenCxpEntry MIB records exist. When one or more wfBacPktGenCxpEntry MIB records are configured, the PktGen CXP Global record is ignored and its processing is disabled." DEFVAL { created } ::= { wfBacPktGenCxpGlobal 1 } wfBacPktGenGlobalStreamMask OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "Bit mask for generating test packets on all CXP streams 1-31. The least significant bit is ignored. The second least significant bit represents stream 1, the next least significant bit represents stream 2, and so forth. The most significant bit represents stream 31." ::= { wfBacPktGenCxpGlobal 2 } wfBacPktGenGlobalRecActive OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the processing of this MIB record is active. It is active only when NO wfBacPktGenCxpEntry MIB record is configured." DEFVAL { inactive } ::= { wfBacPktGenCxpGlobal 3 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenCxpGlobal -- ---------------------------------------------------------------------- wfBacPktGenCctTable OBJECT-TYPE SYNTAX SEQUENCE OF WfBacPktGenCctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The BAC PktGen Circuit table." ::= { wfBacPktGenGroup 5 } wfBacPktGenCctEntry OBJECT-TYPE SYNTAX WfBacPktGenCctEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information concerning a BAC PktGen circuit table entry." INDEX { wfBacPktGenCctNumber } ::= { wfBacPktGenCctTable 1 } WfBacPktGenCctEntry ::= SEQUENCE { wfBacPktGenCctDelete INTEGER, wfBacPktGenCctNumber INTEGER, wfBacPktGenCctState INTEGER, wfBacPktGenCctName DisplayString } wfBacPktGenCctDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete BAC PktGen Circuit table entry." DEFVAL { created } ::= { wfBacPktGenCctEntry 1 } wfBacPktGenCctNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "BAC PktGen circuit number." ::= { wfBacPktGenCctEntry 2 } wfBacPktGenCctState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the BAC PktGen circuit: up - The circuit is up; down - The circuit is down; init - The circuit is initializing; notpresent - The circuit is not present. " DEFVAL { notpresent } ::= { wfBacPktGenCctEntry 3 } wfBacPktGenCctName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "BAC PktGen circuit name." ::= { wfBacPktGenCctEntry 4 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenCctEntry -- ---------------------------------------------------------------------- wfBacPktGenPktFile OBJECT IDENTIFIER ::= { wfBacPktGenGroup 6 } wfBacPktGenPktFileAppend OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Append disable/enable parameter. Default is to release previous table contents instead of appending to previously processed pkt files. This feature is currently not supported." DEFVAL { disable } ::= { wfBacPktGenPktFile 1 } wfBacPktGenPktFileName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The user-defined name of the pktfile to process." ::= { wfBacPktGenPktFile 2 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenPktFile -- ---------------------------------------------------------------------- wfBacPktGenPktGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF WfBacPktGenPktGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The BAC PktGen packet group table." ::= { wfBacPktGenGroup 7 } wfBacPktGenPktGrpEntry OBJECT-TYPE SYNTAX WfBacPktGenPktGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information concerning a BAC PktGen packet group table entry." INDEX { wfBacPktGenPktGrpNumber } ::= { wfBacPktGenPktGrpTable 1 } WfBacPktGenPktGrpEntry ::= SEQUENCE { wfBacPktGenPktGrpNumber INTEGER, wfBacPktGenPktGrpDelay1 INTEGER, wfBacPktGenPktGrpDelay2 INTEGER, wfBacPktGenPktGrpDelay3 INTEGER, wfBacPktGenPktGrpDelay4 INTEGER, wfBacPktGenPktGrpCount1 INTEGER, wfBacPktGenPktGrpCount2 INTEGER, wfBacPktGenPktGrpCount3 INTEGER, wfBacPktGenPktGrpCount4 INTEGER, wfBacPktGenPktSeedSum Counter, wfBacPktGenPktGrpCxp INTEGER } wfBacPktGenPktGrpNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies the packet group number." ::= { wfBacPktGenPktGrpEntry 1 } wfBacPktGenPktGrpDelay1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay parameter 1 for this packet group." ::= { wfBacPktGenPktGrpEntry 2 } wfBacPktGenPktGrpDelay2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay parameter 2 for this packet group." ::= { wfBacPktGenPktGrpEntry 3 } wfBacPktGenPktGrpDelay3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay parameter 3 for this packet group." ::= { wfBacPktGenPktGrpEntry 4 } wfBacPktGenPktGrpDelay4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay parameter 4 for this packet group." ::= { wfBacPktGenPktGrpEntry 5 } wfBacPktGenPktGrpCount1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Count parameter 1 for this packet group." ::= { wfBacPktGenPktGrpEntry 6 } wfBacPktGenPktGrpCount2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Count parameter 2 for this packet group." ::= { wfBacPktGenPktGrpEntry 7 } wfBacPktGenPktGrpCount3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Count parameter 3 for this packet group." ::= { wfBacPktGenPktGrpEntry 8 } wfBacPktGenPktGrpCount4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Count parameter 4 for this packet group." ::= { wfBacPktGenPktGrpEntry 9 } wfBacPktGenPktSeedSum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of packet seeds that belong to this packet group." ::= { wfBacPktGenPktGrpEntry 10 } wfBacPktGenPktGrpCxp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The eligible CXP slot number on which this packet group can be thrown." ::= { wfBacPktGenPktGrpEntry 11 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenPktGrpEntry -- ---------------------------------------------------------------------- wfBacPktGenStrmCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF WfBacPktGenStrmCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The BAC PktGen stream control table." ::= { wfBacPktGenGroup 8 } wfBacPktGenStrmCtrlEntry OBJECT-TYPE SYNTAX WfBacPktGenStrmCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information concerning a BAC PktGen stream control table entry." INDEX { wfBacPktGenStrmNumber, wfBacPktGenStrmCxp } ::= { wfBacPktGenStrmCtrlTable 1 } WfBacPktGenStrmCtrlEntry ::= SEQUENCE { wfBacPktGenStrmNumber INTEGER, wfBacPktGenStrmCxp INTEGER, wfBacPktGenStrmState INTEGER, wfBacPktGenSetStrmPktGrp INTEGER, wfBacPktGenStrmPktGrp INTEGER } wfBacPktGenStrmNumber OBJECT-TYPE SYNTAX INTEGER(1..31) ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies the PktGen stream number on each CXP." ::= { wfBacPktGenStrmCtrlEntry 1 } wfBacPktGenStrmCxp OBJECT-TYPE SYNTAX INTEGER(6..8) ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies the CXP." ::= { wfBacPktGenStrmCtrlEntry 2 } wfBacPktGenStrmState OBJECT-TYPE SYNTAX INTEGER { pktgen(1), killed(2), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of this PktGen stream: pktgen - Stream is transmitting test packets; killed - Stream is being killed; notpresent - Stream is not present. " DEFVAL { notpresent } ::= { wfBacPktGenStrmCtrlEntry 3 } wfBacPktGenSetStrmPktGrp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set the packet group to be thrown by this PktGen stream. " ::= { wfBacPktGenStrmCtrlEntry 4 } wfBacPktGenStrmPktGrp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The packet group which will be thrown by this PktGen stream. " ::= { wfBacPktGenStrmCtrlEntry 5 } ---------------------------------------------------------------------- -- -- end of wfBacPktGenStrmCtrlEntry -- ---------------------------------------------------------------------- END -- BayNetworks-BPKG-MIB