BayNetworks-RCMDS-MIB device MIB details by Wellfleet
BayNetworks-RCMDS-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing BayNetworks-RCMDS-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | BayNetworks-RCMDS-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
BayNetworks-RCMDS-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB wfRcmdsGroup FROM Wellfleet-COMMON-MIB; wfRcmds OBJECT IDENTIFIER ::= { wfRcmdsGroup 1 } wfRcmdsDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete Rcmds." DEFVAL { created } ::= { wfRcmds 1 } wfRcmdsDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or Disables Rcmds Subsystem" DEFVAL { enabled } ::= { wfRcmds 2 } wfRcmdsReservedPort OBJECT-TYPE SYNTAX INTEGER(512..1023) ACCESS read-write STATUS mandatory DESCRIPTION "Next Local reserved port available" DEFVAL { 1023 } ::= { wfRcmds 3 } wfRcmdsKerberosDefaultRealmName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the default kerberos realm name for the router" ::= { wfRcmds 4 } wfRcmdsKerberosKDCName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the default kerberos KDC name to which router sends kerberos ticket requests" ::= { wfRcmds 5 } wfRcmdsRouterHostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the DNS host name for the router" ::= { wfRcmds 6 } wfRcmdsKerberosHostServiceKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This secret equivalent of the content of V5SRVTAB file which contains the host principal keberos private key for the router. This can be manipulated only using the secure shell from the console" ::= { wfRcmds 7 } wfRcmdsRlogind OBJECT IDENTIFIER ::= { wfRcmdsGroup 2 } wfRcmdsRlogindDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete" DEFVAL { created } ::= { wfRcmdsRlogind 1 } wfRcmdsRlogindDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or Disables Rlogind" DEFVAL { enabled } ::= { wfRcmdsRlogind 2 } wfRcmdsRlogindState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "State of Rlogind" DEFVAL { down } ::= { wfRcmdsRlogind 3 } wfRcmdsRlogindMoreDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable the 'more' feature on the Technician Interface console" ::= { wfRcmdsRlogind 4 } wfRcmdsRlogindPrompt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Character string which will be used as the system prompt on the Technician Interface console" ::= { wfRcmdsRlogind 5 } wfRcmdsRlogindLoginTimeOut OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-write STATUS mandatory DESCRIPTION "Time out in minutes to Disconnect when at the login prompt" DEFVAL { 1 } ::= { wfRcmdsRlogind 6 } wfRcmdsRlogindPasswordTimeOut OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-write STATUS mandatory DESCRIPTION "Timout in minutes on Password entry" DEFVAL { 1 } ::= { wfRcmdsRlogind 7 } wfRcmdsRlogindCommandTimeOut OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-write STATUS mandatory DESCRIPTION "Time out in minutes to Disconnect when at the command prompt" DEFVAL { 15 } ::= { wfRcmdsRlogind 8 } wfRcmdsRlogindLoginRetries OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-write STATUS mandatory DESCRIPTION "Limit # of login attempts then Disconnect" DEFVAL { 3 } ::= { wfRcmdsRlogind 9 } wfRcmdsRlogindTotalLogins OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of Rlogind TI login attempts" ::= { wfRcmdsRlogind 10 } wfRcmdsRlogindUserLoginErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FAILED User login attempts" ::= { wfRcmdsRlogind 11 } wfRcmdsRlogindManagerLoginErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FAILED Manager login attempts" ::= { wfRcmdsRlogind 12 } wfRcmdsRlogindOtherLoginErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of FAILED Other login attempts" ::= { wfRcmdsRlogind 13 } wfRcmdsRlogindActiveSessions OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Total number of Rlogind TI Sessions" ::= { wfRcmdsRlogind 14 } wfRcmdsRlogindManagerAutoScript OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "for each login." ::= { wfRcmdsRlogind 15 } wfRcmdsRlogindUserAutoScript OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "for each login." ::= { wfRcmdsRlogind 16 } wfRcmdsRlogindUserAbortLogoutDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "a USER from escaping out of the User Autoscript" DEFVAL { disabled } ::= { wfRcmdsRlogind 17 } wfRcmdsRlogindHistoryDepth OBJECT-TYPE SYNTAX INTEGER(1..40) ACCESS read-write STATUS mandatory DESCRIPTION "TI command history table size" DEFVAL { 20 } ::= { wfRcmdsRlogind 18 } wfRcmdsRlogindTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port on which rlogind listens. by default this is set 543, which supports kerberized rlogin" DEFVAL { 543 } ::= { wfRcmdsRlogind 19 } wfRcmdsRlogindTrustedHostAuthentication OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables Unix trusted host authentication" DEFVAL { disabled } ::= { wfRcmdsRlogind 20 } wfRcmdsRlogindKerberosAuthentication OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables Kerberos Authentication" DEFVAL { enabled } ::= { wfRcmdsRlogind 21 } wfRcmdsRlogindKerberosSessionTypeAllowed OBJECT-TYPE SYNTAX INTEGER { both(1), encrypted(2), unencrypted(3), none(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Encrypted/unencrypted session allowed or not" DEFVAL { both } ::= { wfRcmdsRlogind 22 } wfRcmdsRshd OBJECT IDENTIFIER ::= { wfRcmdsGroup 3 } wfRcmdsRshdDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete" DEFVAL { created } ::= { wfRcmdsRshd 1 } wfRcmdsRshdDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or Disables Rlogind" DEFVAL { enabled } ::= { wfRcmdsRshd 2 } wfRcmdsRshdState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } ACCESS read-only STATUS mandatory DESCRIPTION "State of Rshd" DEFVAL { down } ::= { wfRcmdsRshd 3 } wfRcmdsRshdTotalSessions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of Rshd command sessions executed" ::= { wfRcmdsRshd 4 } wfRcmdsRshdTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port on which rshd listens. by default this is set 544, which supports kerberized rlogin" DEFVAL { 544 } ::= { wfRcmdsRshd 5 } wfRcmdsRshdTrustedHostAuthentication OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables Unix trusted host authentication" DEFVAL { disabled } ::= { wfRcmdsRshd 6 } wfRcmdsRshdKerberosAuthentication OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables Kerberos Authentication" DEFVAL { enabled } ::= { wfRcmdsRshd 7 } wfRcmdsRshdKerberosSessionTypeAllowed OBJECT-TYPE SYNTAX INTEGER { both(1), encrypted(2), unencrypted(3), none(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Encrypted/unencrypted session allowed or not" DEFVAL { both } ::= { wfRcmdsRshd 8 } wfRcmdsRshdRcpDefaultVolume OBJECT-TYPE SYNTAX INTEGER { volume1(1), volume2(2), volume3(3), volume4(4), volume5(5), volume6(6), volume7(7), volume8(8), volume9(9), volume10(10), volume11(11), volume12(12), volume13(13), volume14(14), volumea(65) } ACCESS read-write STATUS mandatory DESCRIPTION "The file system volume number to which transferred files will be written and from which they will be retrieved. The volume number corresponds to the slot number on which the volume resides. On systems with a floppy disk, the value 65 represents volume 'A'." DEFVAL { volume2 } ::= { wfRcmdsRshd 9 } END -- BayNetworks-RCMDS-MIB