Wellfleet-ASR-MIB device MIB details by Wellfleet
Wellfleet-ASR-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-ASR-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-ASR-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-ASR-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB wfAsrGroup FROM Wellfleet-COMMON-MIB; wfAsrBase OBJECT IDENTIFIER ::= { wfAsrGroup 1 } wfAsrBaseCreate OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete ASR." DEFVAL { created } ::= { wfAsrBase 1 } wfAsrBaseEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. Default is enabled. Users perform a set operation on this object in order to enable/disable ASR." DEFVAL { enabled } ::= { wfAsrBase 2 } wfAsrBaseState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpres(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the entire ASR." DEFVAL { notpres } ::= { wfAsrBase 3 } wfAsrNextHopRetryLimit OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "Set the number of next hop entries to try to establish the SVC should the first next hop entry fail." DEFVAL { 2 } ::= { wfAsrBase 4 } wfAsrSecureInFilter OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable inbound packet filtering. This object will be implemented as part of the follow on project." DEFVAL { disable } ::= {wfAsrBase 5} wfAsrSecureInValid OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable inbound call validation. This object will be implemented as part of a follow on project." DEFVAL { disable } ::= { wfAsrBase 6 } wfAsrHoldDownTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The hold down timer is used to prevent retries to a destination that the SVC setup process has failed on. This value would be used if filter/flow spec information is not returned from NHS." DEFVAL { 5 } ::= { wfAsrBase 7 } wfAsrActiveSvcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the SVCs currently active on this router slot." ::= { wfAsrBase 8 } wfAsrFwdTblEntries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of entries in the ASR forward table." ::= { wfAsrBase 9 } wfAsrFwdTblSeq OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Sequence number used to determine changes to the ASR forward table." ::= { wfAsrBase 10 } wfAsrDnsProxyPort OBJECT-TYPE SYNTAX INTEGER { min(1), default(500), max(32550) } ACCESS read-write STATUS mandatory DESCRIPTION "DNS proxy port for QOS translation queries" DEFVAL { default } ::= { wfAsrBase 11 } wfAsrMaxSessions OBJECT-TYPE SYNTAX INTEGER { default(500) } ACCESS read-write STATUS mandatory DESCRIPTION "Maximum number of TCP/IP sessions which are to be managed by ASR." DEFVAL { default } ::= { wfAsrBase 12 } wfAsrDebugLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Debug level in which to enable log messages. The greater the value, the more detailed the log messages." DEFVAL { 0 } ::= { wfAsrBase 13 } wfAsrUseDynRdiscPref OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter for ASR to update the Dynamic Router Discovery Preference value. If enabled, wfRdiscInterfacePref must be 0 in order to advertise the ASR Dynamic Preference." DEFVAL { disable } ::= { wfAsrBase 14 } wfAsrX213PriTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrX213PriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table used by ASR to convert the X.213 priority value returned by NHS to a switch specific Value." ::= { wfAsrGroup 2 } wfAsrX213PriEntry OBJECT-TYPE SYNTAX WfAsrX213PriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "X.213 conversion table." INDEX { wfAsrX213PriLowVal, wfAsrX213PriHiVal } ::= { wfAsrX213PriTable 1 } WfAsrX213PriEntry ::= SEQUENCE { wfAsrX213PriDelete INTEGER, wfAsrX213PriLowVal INTEGER, wfAsrX213PriHiVal INTEGER, wfAsrX213PriSwVal INTEGER } wfAsrX213PriDelete OBJECT-TYPE SYNTAX INTEGER { created (1), deleted (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/delete indicator for X.213 priority table entry." DEFVAL { created } ::= { wfAsrX213PriEntry 1 } wfAsrX213PriLowVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Low value of X.213 priority range." ::= { wfAsrX213PriEntry 2 } wfAsrX213PriHiVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "High value of X.213 priority range." ::= { wfAsrX213PriEntry 3 } wfAsrX213PriSwVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Switch specific X.213 priority value." ::= { wfAsrX213PriEntry 4 } wfAsrRtrPriTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrRtrPriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table used by ASR to convert the router priority value returned by NHS to a router priority queue." ::= { wfAsrGroup 3 } wfAsrRtrPriEntry OBJECT-TYPE SYNTAX WfAsrRtrPriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Router priority conversion table." INDEX { wfAsrRtrPriLowVal, wfAsrRtrPriHiVal } ::= { wfAsrRtrPriTable 1 } WfAsrRtrPriEntry ::= SEQUENCE { wfAsrRtrPriDelete INTEGER, wfAsrRtrPriLowVal INTEGER, wfAsrRtrPriHiVal INTEGER, wfAsrRtrPriCvtVal INTEGER } wfAsrRtrPriDelete OBJECT-TYPE SYNTAX INTEGER { created (1), deleted (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/delete indicator for Router priority table entry." DEFVAL { created } ::= { wfAsrRtrPriEntry 1 } wfAsrRtrPriLowVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Low value of router priority range." ::= { wfAsrRtrPriEntry 2 } wfAsrRtrPriHiVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "High value of router priority range." ::= { wfAsrRtrPriEntry 3 } wfAsrRtrPriCvtVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Router priority Queue value." ::= { wfAsrRtrPriEntry 4 } wfAsrMultiHopTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrMultiHopEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table used by ASR to identify those PVCs that can be used as a multi hop path or overlay network." ::= { wfAsrGroup 4 } wfAsrMultiHopEntry OBJECT-TYPE SYNTAX WfAsrMultiHopEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Multi Hop PVC identification." INDEX { wfAsrMhCircuitNumber, wfAsrMhVcid1, wfAsrMhVcid2} ::= { wfAsrMultiHopTable 1 } WfAsrMultiHopEntry ::= SEQUENCE { wfAsrMultiHopDelete INTEGER, wfAsrMhCircuitNumber INTEGER, wfAsrMhVcid1 INTEGER, wfAsrMhVcid2 INTEGER } wfAsrMultiHopDelete OBJECT-TYPE SYNTAX INTEGER { created (1), deleted (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/delete indicator for multi hop table entry." DEFVAL { created } ::= { wfAsrMultiHopEntry 1 } wfAsrMhCircuitNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Instance identifier. The circuit number of this interface." ::= { wfAsrMultiHopEntry 2 } wfAsrMhVcid1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "VCID 1 value. The Dlci number for Frame Relay, the VPI for ATM." ::= { wfAsrMultiHopEntry 3 } wfAsrMhVcid2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "VCID 2 value. The VCI for ATM, NULL for Frame Relay." ::= { wfAsrMultiHopEntry 4 } wfAsrDirectExceptTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrDirectExceptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The directional exception asymmetric route avoidance table. This tables index is made up of the protocol and service field." ::= { wfAsrGroup 5 } wfAsrDirectExceptEntry OBJECT-TYPE SYNTAX WfAsrDirectExceptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ASR directional exception table." INDEX { wfAsrServiceProtocol, wfAsrServicePort} ::= { wfAsrDirectExceptTable 1 } WfAsrDirectExceptEntry ::= SEQUENCE { wfAsrServiceProtocol INTEGER, wfAsrServicePort INTEGER, wfAsrSrcPortLow INTEGER, wfAsrSrcPortHigh INTEGER, wfAsrDestPortLow INTEGER, wfAsrDestPortHigh INTEGER } wfAsrServiceProtocol OBJECT-TYPE SYNTAX INTEGER { tcp(6), udp(17) } ACCESS read-write STATUS mandatory DESCRIPTION "Service protocol indicates what protocol this entry is for. Coices are UDP or TCP." ::= { wfAsrDirectExceptEntry 1 } wfAsrServicePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Application port number of service connecting to." ::= { wfAsrDirectExceptEntry 2 } wfAsrSrcPortLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Low port number of application serving as source used at host site." ::= { wfAsrDirectExceptEntry 3 } wfAsrSrcPortHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "High port number of application serving as source used at host site." ::= { wfAsrDirectExceptEntry 4 } wfAsrDestPortLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Low port number of application serving as destination used at client site." ::= { wfAsrDirectExceptEntry 5 } wfAsrDestPortHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "High port number of application serving as destination used at client site." ::= { wfAsrDirectExceptEntry 6 } wfAsrCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table which contains configuration information for each circuit defined to ASR but not specific to a specific circuit. The table is indexed by circuit number." ::= { wfAsrGroup 6 } wfAsrCircuitEntry OBJECT-TYPE SYNTAX WfAsrCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An ASR circuit description" INDEX { wfAsrCircuitNumber } ::= { wfAsrCircuitTable 1 } WfAsrCircuitEntry ::= SEQUENCE { wfAsrCircuitCreate INTEGER, wfAsrCircuitEnable INTEGER, wfAsrCircuitState INTEGER, wfAsrCircuitNumber INTEGER, wfAsrCircuitCallCtrl INTEGER, wfAsrCircuitInReceives Counter, wfAsrCircuitInDiscards Counter, wfAsrCircuitSetupRequests Counter, wfAsrCircuitSetupSucc Counter, wfAsrCircuitSetupFail Counter, wfAsrCircuitSVCsEstablished Counter, wfAsrNegativeNHR Counter, wfAsrSvcOutboundReqFail Counter, wfAsrSvcInboundFilterFail Counter, wfAsrSvcInboundCallValFail Counter } wfAsrCircuitCreate OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete an ASR circuit." DEFVAL { create } ::= { wfAsrCircuitEntry 1 } wfAsrCircuitEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter. Default is enabled. Users perform a set operation on this object in order to enable/disable an ASR circuit." DEFVAL { enable } ::= { wfAsrCircuitEntry 2 } wfAsrCircuitState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), invalid(4), notpres(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Invalid indicates an error in processing the cfg record" DEFVAL { notpres } ::= { wfAsrCircuitEntry 3 } wfAsrCircuitNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Instance identifier. The circuit number of this interface." ::= { wfAsrCircuitEntry 4 } wfAsrCircuitCallCtrl OBJECT-TYPE SYNTAX INTEGER { inboundonly (1), outboundonly (2), inboundandoutbound (3), none (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Define call policy for this SVC circuit. 1) allow inbound calls only 2) allow outbound calls only 3)allow inbound and outbound calls 4) allow neither inbound or outbound calls." DEFVAL { outboundonly } ::= { wfAsrCircuitEntry 5 } wfAsrCircuitInReceives OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of input datagrams received at the circuit, including those received in error." ::= { wfAsrCircuitEntry 6 } wfAsrCircuitInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of input datagrams discarded due to failed setup attempts, unreachable destinations, etc." ::= { wfAsrCircuitEntry 7 } wfAsrCircuitSetupRequests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SVC setup requests attempted on the circuit , including those which failed." ::= { wfAsrCircuitEntry 8 } wfAsrCircuitSetupSucc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SVC setup requests attempted on the circuit which resulted in an SVC being established." ::= { wfAsrCircuitEntry 9 } wfAsrCircuitSetupFail OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SVC setup requests attempted on the circuit which resulted in an SVC not being established." ::= { wfAsrCircuitEntry 10 } wfAsrCircuitSVCsEstablished OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SVCs currently established on the circuit." ::= { wfAsrCircuitEntry 11 } wfAsrNegativeNHR OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Count of negative NHR responses received from NHRP." ::= { wfAsrCircuitEntry 12 } wfAsrSvcOutboundReqFail OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Count of outbound requests for SVCs that failed." ::= { wfAsrCircuitEntry 13 } wfAsrSvcInboundFilterFail OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Count of inbound packets failing inbound packet filtering." ::= { wfAsrCircuitEntry 14 } wfAsrSvcInboundCallValFail OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Count of inbound SVC call validation failures." ::= { wfAsrCircuitEntry 15 } wfAsrFiltTable OBJECT-TYPE SYNTAX SEQUENCE OF WfAsrFiltEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing setup information related to an SVC. The table is indexed by slot,dest ip addr and mask, source ip addr and mask, source and dest port ranges and protocol." ::= { wfAsrGroup 7 } wfAsrFiltEntry OBJECT-TYPE SYNTAX WfAsrFiltEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ASR SVC setup information." INDEX { wfAsrFilterSlot, wfAsrDestIpAddr, wfAsrDestIpMask, wfAsrSourceIpAddr, wfAsrSourceIpMask, wfAsrDestPortRangeLow, wfAsrDestPortRangeHigh, wfAsrSourcePortRangeLow, wfAsrSourcePortRangeHigh, wfAsrIPProtocol } ::= { wfAsrFiltTable 1 } WfAsrFiltEntry ::= SEQUENCE { wfAsrFilterCreate INTEGER, wfAsrFilterSlot INTEGER, wfAsrDestIpAddr IpAddress, wfAsrDestIpMask IpAddress, wfAsrSourceIpAddr IpAddress, wfAsrSourceIpMask IpAddress, wfAsrDestPortRangeLow INTEGER, wfAsrDestPortRangeHigh INTEGER, wfAsrSourcePortRangeLow INTEGER, wfAsrSourcePortRangeHigh INTEGER, wfAsrIPProtocol INTEGER, wfAsrFilterTtl INTEGER, wfAsrFilterType DisplayString, wfAsrSvcCircuitNumber INTEGER, wfAsrSvcVcid1 INTEGER, wfAsrSvcVcid2 INTEGER, wfAsrSvcCalledAddr DisplayString, wfAsrSvcSetupTime INTEGER, wfAsrSvcType INTEGER, wfAsrSvcMTU INTEGER, wfAsrSvcRouterPriOut INTEGER, wfAsrFrSvcCIRIn INTEGER, wfAsrFrSvcCIROut INTEGER, wfAsrFrSvcBCIn INTEGER, wfAsrFrSvcBCOut INTEGER, wfAsrFrSvcBEIn INTEGER, wfAsrFrSvcBEOut INTEGER, wfAsrFrSvcX213Pri INTEGER, wfAsrAtmSvcPCRIn INTEGER, wfAsrAtmSvcPCROut INTEGER, wfAsrAtmSvcSCRIn INTEGER, wfAsrAtmSvcSCROut INTEGER, wfAsrAtmSvcMBSIn INTEGER, wfAsrAtmSvcMBSOut INTEGER, wfAsrAtmSvcQOSClassIn INTEGER, wfAsrAtmSvcQOSClassOut INTEGER, wfAsrAtmSvcCDVTIn INTEGER, wfAsrAtmSvcCDVTOut INTEGER, wfAsrAtmSvcCLRIn INTEGER, wfAsrAtmSvcCLROut INTEGER } wfAsrFilterCreate OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/delete this filter entry." ::= { wfAsrFiltEntry 1 } wfAsrFilterSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The router slot on which this filter exists." ::= { wfAsrFiltEntry 2 } wfAsrDestIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Filter destination IP address reference value." ::= { wfAsrFiltEntry 3 } wfAsrDestIpMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Filter destination IP address mask." ::= { wfAsrFiltEntry 4 } wfAsrSourceIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Filter source IP address reference value." ::= { wfAsrFiltEntry 5 } wfAsrSourceIpMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Filter source IP address mask." ::= { wfAsrFiltEntry 6 } wfAsrDestPortRangeLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The low value for the range of TCP/UDP destination ports." ::= { wfAsrFiltEntry 7 } wfAsrDestPortRangeHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The high value for the range of TCP/UDP destination ports." ::= { wfAsrFiltEntry 8 } wfAsrSourcePortRangeLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The low value for the range of TCP/UDP source ports." ::= { wfAsrFiltEntry 9 } wfAsrSourcePortRangeHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The high value for the range of TCP/UDP source ports." ::= { wfAsrFiltEntry 10 } wfAsrIPProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "IP protocol for this filter (TCP or UDP)." ::= { wfAsrFiltEntry 11 } wfAsrFilterTtl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For SVC filters, this is the SVC idle time (seconds). For all other filter types, this is the filter expiration time (seconds)." ::= { wfAsrFiltEntry 12 } wfAsrFilterType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Type of filter (SVC, NOSVC, in-progress, dest unreachable)." ::= { wfAsrFiltEntry 13 } wfAsrSvcCircuitNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit number on which the SVC is created." ::= { wfAsrFiltEntry 14 } wfAsrSvcVcid1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For Frame Relay SVCs, this is the DLCI value. For ATM SVCs, this is the VPI value." ::= { wfAsrFiltEntry 15 } wfAsrSvcVcid2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For ATM SVCs, this is the VCI value." ::= { wfAsrFiltEntry 16 } wfAsrSvcCalledAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SVC Called Party Address" ::= { wfAsrFiltEntry 17 } wfAsrSvcSetupTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of when the SVC was created." ::= { wfAsrFiltEntry 18 } wfAsrSvcType OBJECT-TYPE SYNTAX INTEGER { fr(1), atm(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of SVC created (Frame Relay or ATM)." ::= { wfAsrFiltEntry 19 } wfAsrSvcMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum transmission unit for this SVC." ::= { wfAsrFiltEntry 20 } wfAsrSvcRouterPriOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The router priority queue to be used for the packets sent on this SVC." ::= { wfAsrFiltEntry 21 } wfAsrFrSvcCIRIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay SVC commited information rate - inbound (bps)." ::= { wfAsrFiltEntry 22 } wfAsrFrSvcCIROut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay SVC commited information rate - outbound (bps)." ::= { wfAsrFiltEntry 23 } wfAsrFrSvcBCIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay commited burst rate for SVC - inbound (bps)." ::= { wfAsrFiltEntry 24 } wfAsrFrSvcBCOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay commited burst rate for the SVC - outbound (bps)." ::= { wfAsrFiltEntry 25 } wfAsrFrSvcBEIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay excess burst rate for the SVC - inbound (bps)." ::= { wfAsrFiltEntry 26 } wfAsrFrSvcBEOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay excess burst rate for the SVC - outbound (bps)." ::= { wfAsrFiltEntry 27 } wfAsrFrSvcX213Pri OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Frame Relay SVC X.213 data priority value passed to the switch during call setup." ::= { wfAsrFiltEntry 28 } wfAsrAtmSvcPCRIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Peak Cell Rate - inbound." ::= { wfAsrFiltEntry 29 } wfAsrAtmSvcPCROut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Peak Cell Rate - outbound." ::= { wfAsrFiltEntry 30 } wfAsrAtmSvcSCRIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Sustainable Cell Rate - inbound." ::= { wfAsrFiltEntry 31 } wfAsrAtmSvcSCROut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Sustainable Cell Rate - outbound." ::= { wfAsrFiltEntry 32 } wfAsrAtmSvcMBSIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Maximum Burst Size - inbound." ::= { wfAsrFiltEntry 33 } wfAsrAtmSvcMBSOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Maximum Burst Size - outbound." ::= { wfAsrFiltEntry 34 } wfAsrAtmSvcQOSClassIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Quality of Service - inbound. Class 0 through 4." ::= { wfAsrFiltEntry 35 } wfAsrAtmSvcQOSClassOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Quality of Service - outbound. Class 0 through 4." ::= { wfAsrFiltEntry 36 } wfAsrAtmSvcCDVTIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Cell Delay Variation Tolerance - inbound." ::= { wfAsrFiltEntry 37 } wfAsrAtmSvcCDVTOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Cell Delay Variation Tolerance - outbound." ::= { wfAsrFiltEntry 38 } wfAsrAtmSvcCLRIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Cell Loss Ratio - inbound." ::= { wfAsrFiltEntry 39 } wfAsrAtmSvcCLROut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ATM SVC Cell Loss Ratio - outbound." ::= { wfAsrFiltEntry 40 } wfAsrTest OBJECT IDENTIFIER ::= { wfAsrGroup 8 } wfAsrTestCreate OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter. Default is created. Users perform a set operation on this object in order to create/delete ASR Test Object." DEFVAL { created } ::= { wfAsrTest 1 } wfAsrTestChangeVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value to set the protocol field in the ASR Fwd Table. This will take the SVC entry matching the Dlci and Cct number and change the filter. This is used only for Inbound Pkt Filtering tests" DEFVAL { 6 } ::= { wfAsrTest 2 } wfAsrTestDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Dlci of SVC Filter entry to change" ::= { wfAsrTest 3 } wfAsrTestCct OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Circuit number of SVC Filter to change" ::= { wfAsrTest 4 } END -- Wellfleet-ASR-MIB