Wellfleet-DS3-MIB device MIB details by Wellfleet
Wellfleet-DS3-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-DS3-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-DS3-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-DS3-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:40:18 EDT 1995 IMPORTS IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, mib-2 FROM RFC1213-MIB wfDs3Group FROM Wellfleet-COMMON-MIB; wfDs3Config OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Configuration table" ::= { wfDs3Group 1 } wfDs3ConfigEntry OBJECT-TYPE SYNTAX WfDs3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number" INDEX { wfDs3LineIndex } ::= { wfDs3Config 1 } WfDs3ConfigEntry ::= SEQUENCE { wfDs3LineIndex INTEGER, wfDs3TimeElapsed INTEGER, wfDs3ValidIntervals INTEGER, wfDs3LineType INTEGER, wfDs3ZeroCoding INTEGER, wfDs3SendCode INTEGER, wfDs3CircuitIdentifier DisplayString, wfDs3LoopbackConfig INTEGER, wfDs3LineStatus INTEGER } wfDs3LineIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3ConfigEntry 1 } wfDs3TimeElapsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1..900 seconds within the current 15-minute interval" ::= { wfDs3ConfigEntry 2 } wfDs3ValidIntervals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours." ::= { wfDs3ConfigEntry 3 } wfDs3LineType OBJECT-TYPE SYNTAX INTEGER { other(1), ds3cbitparity(4), ds3clearchannel(5) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of DS3 implementing this circuit" ::= { wfDs3ConfigEntry 4 } wfDs3ZeroCoding OBJECT-TYPE SYNTAX INTEGER { ds3b3zs(2) } ACCESS read-only STATUS mandatory DESCRIPTION "the variety of Zero Code Suppression used on the link" ::= { wfDs3ConfigEntry 5 } wfDs3SendCode OBJECT-TYPE SYNTAX INTEGER { ds3sendnocode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "the type of code being sent across the DS3 circuit by the CSU" ::= { wfDs3ConfigEntry 6 } wfDs3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "the transmission vendor's circuit identifier" ::= { wfDs3ConfigEntry 7 } wfDs3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { ds3noloop(1), ds3mgrpayloadloop(2), ds3mgrlineloop(3), ds3netreqpayloadloop(4), ds3netreqlineloop(5), ds3otherloop(6) } ACCESS read-only STATUS mandatory DESCRIPTION "the loopback state of the CSU" ::= { wfDs3ConfigEntry 8 } wfDs3LineStatus OBJECT-TYPE SYNTAX INTEGER { ds3noalarm(1), ds3farendalarm(2), ds3alarmindicationsignal(4), ds3lossofframe(8), ds3lossofsignal(16), ds3loopbackstate(32) } ACCESS read-only STATUS mandatory DESCRIPTION "the state of the DS3 line" ::= { wfDs3ConfigEntry 9 } wfDs3Current OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Current table" ::= { wfDs3Group 2 } wfDs3CurrentEntry OBJECT-TYPE SYNTAX WfDs3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs3CurrentIndex } ::= { wfDs3Current 1 } WfDs3CurrentEntry ::= SEQUENCE { wfDs3CurrentIndex INTEGER, wfDs3CurrentESs Counter, wfDs3CurrentSESs Counter, wfDs3CurrentSEFs Counter, wfDs3CurrentUASs Counter, wfDs3CurrentBPVs Counter, wfDs3CurrentCVs Counter } wfDs3CurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3CurrentEntry 1 } wfDs3CurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs3CurrentEntry 2 } wfDs3CurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs3CurrentEntry 3 } wfDs3CurrentSEFs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the current interval" ::= { wfDs3CurrentEntry 4 } wfDs3CurrentUASs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the current interval" ::= { wfDs3CurrentEntry 5 } wfDs3CurrentBPVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the current interval" ::= { wfDs3CurrentEntry 6 } wfDs3CurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs3CurrentEntry 7 } wfDs3Interval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Interval table" ::= { wfDs3Group 3 } wfDs3IntervalEntry OBJECT-TYPE SYNTAX WfDs3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs3IntervalIndex, wfDs3IntervalNumber } ::= { wfDs3Interval 1 } WfDs3IntervalEntry ::= SEQUENCE { wfDs3IntervalIndex INTEGER, wfDs3IntervalNumber INTEGER, wfDs3IntervalESs Gauge, wfDs3IntervalSESs Gauge, wfDs3IntervalSEFs Gauge, wfDs3IntervalUASs Gauge, wfDs3IntervalBPVs Gauge, wfDs3IntervalCVs Gauge } wfDs3IntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3IntervalEntry 1 } wfDs3IntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs3IntervalEntry 2 } wfDs3IntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs3IntervalEntry 3 } wfDs3IntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs3IntervalEntry 4 } wfDs3IntervalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored framing seconds in the specified interval" ::= { wfDs3IntervalEntry 5 } wfDs3IntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the number of unavailable seconds in the specified interval" ::= { wfDs3IntervalEntry 6 } wfDs3IntervalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of bipolar violations in the specified interval" ::= { wfDs3IntervalEntry 7 } wfDs3IntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs3IntervalEntry 8 } wfDs3Total OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Total table" ::= { wfDs3Group 4 } wfDs3TotalEntry OBJECT-TYPE SYNTAX WfDs3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3TotalIndex } ::= { wfDs3Total 1 } WfDs3TotalEntry ::= SEQUENCE { wfDs3TotalIndex INTEGER, wfDs3TotalESs Gauge, wfDs3TotalSESs Gauge, wfDs3TotalSEFs Gauge, wfDs3TotalUASs Gauge, wfDs3TotalBPVs Gauge, wfDs3TotalCVs Gauge } wfDs3TotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3TotalEntry 1 } wfDs3TotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs3TotalEntry 2 } wfDs3TotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs3TotalEntry 3 } wfDs3TotalSEFs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored framing seconds" ::= { wfDs3TotalEntry 4 } wfDs3TotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total number of unavailable seconds" ::= { wfDs3TotalEntry 5 } wfDs3TotalBPVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of bipolar violations" ::= { wfDs3TotalEntry 6 } wfDs3TotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs3TotalEntry 7 } wfDs3FeConfig OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Configuration table" ::= { wfDs3Group 5 } wfDs3FeConfigEntry OBJECT-TYPE SYNTAX WfDs3FeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeConfigIndex } ::= { wfDs3FeConfig 1 } WfDs3FeConfigEntry ::= SEQUENCE { wfDs3FeConfigIndex INTEGER, wfDs3FarEndEquipCode DisplayString, wfDs3FarEndLocationIDCode DisplayString, wfDs3FarEndFrameIDCode DisplayString, wfDs3FarEndUnitCode DisplayString, wfDs3FarEndFacilityIDCode DisplayString } wfDs3FeConfigIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeConfigEntry 1 } wfDs3FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "equipment description code - C-bit parity only" ::= { wfDs3FeConfigEntry 2 } wfDs3FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "equipment location code - C-bit parity only" ::= { wfDs3FeConfigEntry 3 } wfDs3FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "code for the equipment location within a building" ::= { wfDs3FeConfigEntry 4 } wfDs3FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "code for the equipment location within a bay" ::= { wfDs3FeConfigEntry 5 } wfDs3FarEndFacilityIDCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "path identification code" ::= { wfDs3FeConfigEntry 6 } wfDs3FeCurrent OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Current table" ::= { wfDs3Group 6 } wfDs3FeCurrentEntry OBJECT-TYPE SYNTAX WfDs3FeCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeCurrentIndex } ::= { wfDs3FeCurrent 1 } WfDs3FeCurrentEntry ::= SEQUENCE { wfDs3FeCurrentIndex INTEGER, wfDs3FeCurrentESs Counter, wfDs3FeCurrentSESs Counter, wfDs3FeCurrentCVs Counter } wfDs3FeCurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeCurrentEntry 1 } wfDs3FeCurrentESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the current interval" ::= { wfDs3FeCurrentEntry 2 } wfDs3FeCurrentSESs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the current interval" ::= { wfDs3FeCurrentEntry 3 } wfDs3FeCurrentCVs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the current interval" ::= { wfDs3FeCurrentEntry 4 } wfDs3FeInterval OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Interval table" ::= { wfDs3Group 7 } wfDs3FeIntervalEntry OBJECT-TYPE SYNTAX WfDs3FeIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval" INDEX { wfDs3FeIntervalIndex, wfDs3FeIntervalNumber } ::= { wfDs3FeInterval 1 } WfDs3FeIntervalEntry ::= SEQUENCE { wfDs3FeIntervalIndex INTEGER, wfDs3FeIntervalNumber INTEGER, wfDs3FeIntervalESs Gauge, wfDs3FeIntervalSESs Gauge, wfDs3FeIntervalCVs Gauge } wfDs3FeIntervalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeIntervalEntry 1 } wfDs3FeIntervalNumber OBJECT-TYPE SYNTAX INTEGER(1..96) ACCESS read-only STATUS mandatory DESCRIPTION "1..96 where 1 is the most recent 15-minute interval and 96 is the least" ::= { wfDs3FeIntervalEntry 2 } wfDs3FeIntervalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of errored seconds in the specified interval" ::= { wfDs3FeIntervalEntry 3 } wfDs3FeIntervalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of severely errored seconds in the specified interval" ::= { wfDs3FeIntervalEntry 4 } wfDs3FeIntervalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "the count of code violation error events in the specified interval" ::= { wfDs3FeIntervalEntry 5 } wfDs3FeTotal OBJECT-TYPE SYNTAX SEQUENCE OF WfDs3FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Total table" ::= { wfDs3Group 8 } wfDs3FeTotalEntry OBJECT-TYPE SYNTAX WfDs3FeTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "per circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number" INDEX { wfDs3FeTotalIndex } ::= { wfDs3FeTotal 1 } WfDs3FeTotalEntry ::= SEQUENCE { wfDs3FeTotalIndex INTEGER, wfDs3FeTotalESs Gauge, wfDs3FeTotalSESs Gauge, wfDs3FeTotalCVs Gauge } wfDs3FeTotalIndex OBJECT-TYPE SYNTAX INTEGER(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "this corresponds to the Wellfleet circuit number" ::= { wfDs3FeTotalEntry 1 } wfDs3FeTotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of errored seconds" ::= { wfDs3FeTotalEntry 2 } wfDs3FeTotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of severely errored seconds" ::= { wfDs3FeTotalEntry 3 } wfDs3FeTotalCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "total count of code violation error events" ::= { wfDs3FeTotalEntry 4 } END -- Wellfleet-DS3-MIB