MonitorTools.com » Technical documentation » SNMP » MIB » Wellfleet » Wellfleet-DS3-MIB » Objects

Wellfleet-DS3-MIB.mib object view, vendor Wellfleet

Introduction

Most network devices and programs ship with so-called MIB files to describe the parameters and meanings (i.e.: friendly names) which are available for monitoring via SNMP.
ActiveXperts Network Monitor 2024 can import vendor-specific MIB files, so it can be used to monitor specific OID's (Object Identifiers). This way, you can monitor your devices, computers, etc. by selecting your relevant OID's by name.

ActiveXperts Network Monitor 2024 can import MIB file Wellfleet-DS3-MIB and use it to monitor vendor specific OID's.

Wellfleet-DS3-MIB file content

Object view of Wellfleet-DS3-MIB:

Scalar Object
wfDs3ConfigEntry .1.3.6.1.4.1.18.3.4.13.1.1
per circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number
wfDs3CurrentEntry .1.3.6.1.4.1.18.3.4.13.2.1
per circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number
wfDs3IntervalEntry .1.3.6.1.4.1.18.3.4.13.3.1
per circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval
wfDs3TotalEntry .1.3.6.1.4.1.18.3.4.13.4.1
per circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number
wfDs3FeConfigEntry .1.3.6.1.4.1.18.3.4.13.5.1
per circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number
wfDs3FeCurrentEntry .1.3.6.1.4.1.18.3.4.13.6.1
per circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number
wfDs3FeIntervalEntry .1.3.6.1.4.1.18.3.4.13.7.1
per circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval
wfDs3FeTotalEntry .1.3.6.1.4.1.18.3.4.13.8.1
per circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number
Tabular Object
wfDs3LineIndex .1.3.6.1.4.1.18.3.4.13.1.1.1
this corresponds to the Wellfleet circuit number
wfDs3TimeElapsed .1.3.6.1.4.1.18.3.4.13.1.1.2
1..900 seconds within the current 15-minute interval
wfDs3ValidIntervals .1.3.6.1.4.1.18.3.4.13.1.1.3
0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours.
wfDs3LineType .1.3.6.1.4.1.18.3.4.13.1.1.4
the variety of DS3 implementing this circuit
wfDs3ZeroCoding .1.3.6.1.4.1.18.3.4.13.1.1.5
the variety of Zero Code Suppression used on the link
wfDs3SendCode .1.3.6.1.4.1.18.3.4.13.1.1.6
the type of code being sent across the DS3 circuit by the CSU
wfDs3CircuitIdentifier .1.3.6.1.4.1.18.3.4.13.1.1.7
the transmission vendor's circuit identifier
wfDs3LoopbackConfig .1.3.6.1.4.1.18.3.4.13.1.1.8
the loopback state of the CSU
wfDs3LineStatus .1.3.6.1.4.1.18.3.4.13.1.1.9
the state of the DS3 line
wfDs3CurrentIndex .1.3.6.1.4.1.18.3.4.13.2.1.1
this corresponds to the Wellfleet circuit number
wfDs3CurrentESs .1.3.6.1.4.1.18.3.4.13.2.1.2
the count of errored seconds in the current interval
wfDs3CurrentSESs .1.3.6.1.4.1.18.3.4.13.2.1.3
the count of severely errored seconds in the current interval
wfDs3CurrentSEFs .1.3.6.1.4.1.18.3.4.13.2.1.4
the count of severely errored framing seconds in the current interval
wfDs3CurrentUASs .1.3.6.1.4.1.18.3.4.13.2.1.5
the number of unavailable seconds in the current interval
wfDs3CurrentBPVs .1.3.6.1.4.1.18.3.4.13.2.1.6
the count of bipolar violations in the current interval
wfDs3CurrentCVs .1.3.6.1.4.1.18.3.4.13.2.1.7
the count of code violation error events in the current interval
wfDs3IntervalIndex .1.3.6.1.4.1.18.3.4.13.3.1.1
this corresponds to the Wellfleet circuit number
wfDs3IntervalNumber .1.3.6.1.4.1.18.3.4.13.3.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
wfDs3IntervalESs .1.3.6.1.4.1.18.3.4.13.3.1.3
the count of errored seconds in the specified interval
wfDs3IntervalSESs .1.3.6.1.4.1.18.3.4.13.3.1.4
the count of severely errored seconds in the specified interval
wfDs3IntervalSEFs .1.3.6.1.4.1.18.3.4.13.3.1.5
the count of severely errored framing seconds in the specified interval
wfDs3IntervalUASs .1.3.6.1.4.1.18.3.4.13.3.1.6
the number of unavailable seconds in the specified interval
wfDs3IntervalBPVs .1.3.6.1.4.1.18.3.4.13.3.1.7
the count of bipolar violations in the specified interval
wfDs3IntervalCVs .1.3.6.1.4.1.18.3.4.13.3.1.8
the count of code violation error events in the specified interval
wfDs3TotalIndex .1.3.6.1.4.1.18.3.4.13.4.1.1
this corresponds to the Wellfleet circuit number
wfDs3TotalESs .1.3.6.1.4.1.18.3.4.13.4.1.2
total count of errored seconds
wfDs3TotalSESs .1.3.6.1.4.1.18.3.4.13.4.1.3
total count of severely errored seconds
wfDs3TotalSEFs .1.3.6.1.4.1.18.3.4.13.4.1.4
total count of severely errored framing seconds
wfDs3TotalUASs .1.3.6.1.4.1.18.3.4.13.4.1.5
total number of unavailable seconds
wfDs3TotalBPVs .1.3.6.1.4.1.18.3.4.13.4.1.6
total count of bipolar violations
wfDs3TotalCVs .1.3.6.1.4.1.18.3.4.13.4.1.7
total count of code violation error events
wfDs3FeConfigIndex .1.3.6.1.4.1.18.3.4.13.5.1.1
this corresponds to the Wellfleet circuit number
wfDs3FarEndEquipCode .1.3.6.1.4.1.18.3.4.13.5.1.2
equipment description code - C-bit parity only
wfDs3FarEndLocationIDCode .1.3.6.1.4.1.18.3.4.13.5.1.3
equipment location code - C-bit parity only
wfDs3FarEndFrameIDCode .1.3.6.1.4.1.18.3.4.13.5.1.4
code for the equipment location within a building
wfDs3FarEndUnitCode .1.3.6.1.4.1.18.3.4.13.5.1.5
code for the equipment location within a bay
wfDs3FarEndFacilityIDCode .1.3.6.1.4.1.18.3.4.13.5.1.6
path identification code
wfDs3FeCurrentIndex .1.3.6.1.4.1.18.3.4.13.6.1.1
this corresponds to the Wellfleet circuit number
wfDs3FeCurrentESs .1.3.6.1.4.1.18.3.4.13.6.1.2
the count of errored seconds in the current interval
wfDs3FeCurrentSESs .1.3.6.1.4.1.18.3.4.13.6.1.3
the count of severely errored seconds in the current interval
wfDs3FeCurrentCVs .1.3.6.1.4.1.18.3.4.13.6.1.4
the count of code violation error events in the current interval
wfDs3FeIntervalIndex .1.3.6.1.4.1.18.3.4.13.7.1.1
this corresponds to the Wellfleet circuit number
wfDs3FeIntervalNumber .1.3.6.1.4.1.18.3.4.13.7.1.2
1..96 where 1 is the most recent 15-minute interval and 96 is the least
wfDs3FeIntervalESs .1.3.6.1.4.1.18.3.4.13.7.1.3
the count of errored seconds in the specified interval
wfDs3FeIntervalSESs .1.3.6.1.4.1.18.3.4.13.7.1.4
the count of severely errored seconds in the specified interval
wfDs3FeIntervalCVs .1.3.6.1.4.1.18.3.4.13.7.1.5
the count of code violation error events in the specified interval
wfDs3FeTotalIndex .1.3.6.1.4.1.18.3.4.13.8.1.1
this corresponds to the Wellfleet circuit number
wfDs3FeTotalESs .1.3.6.1.4.1.18.3.4.13.8.1.2
total count of errored seconds
wfDs3FeTotalSESs .1.3.6.1.4.1.18.3.4.13.8.1.3
total count of severely errored seconds
wfDs3FeTotalCVs .1.3.6.1.4.1.18.3.4.13.8.1.4
total count of code violation error events
Table
wfDs3Config .1.3.6.1.4.1.18.3.4.13.1
The DS3 Configuration table
wfDs3Current .1.3.6.1.4.1.18.3.4.13.2
The DS3 Current table
wfDs3Interval .1.3.6.1.4.1.18.3.4.13.3
The DS3 Interval table
wfDs3Total .1.3.6.1.4.1.18.3.4.13.4
The DS3 Total table
wfDs3FeConfig .1.3.6.1.4.1.18.3.4.13.5
The DS3 Far End Configuration table
wfDs3FeCurrent .1.3.6.1.4.1.18.3.4.13.6
The DS3 Far End Current table
wfDs3FeInterval .1.3.6.1.4.1.18.3.4.13.7
The DS3 Far End Interval table
wfDs3FeTotal .1.3.6.1.4.1.18.3.4.13.8
The DS3 Far End Total table